Montage / Installation. Kontakt / Support * AM1/E. Außentemperatur-Messumformer Outdoor Temperature Transducer
|
|
- Silke Knopp
- vor 5 Jahren
- Abrufe
Transkript
1 Mtage / Installati D GB ÖFFNEN / OPEN SCHLIESSEN / CLOSE, 1. insert slotted screwdriver (with appropriate size) into the slot 2. by ing to the housing centre hinge will open 3. open cover to the left close hinge to the upper part 3. Außentemperatur-Messumformer Outdoor Temperature Transducer Außentemperatur-Messumformer mit Hülse Outdoor Temperature Transducer with Sleeve Aussentemperatur-Messumformer mit EMV-Verschraubung Outdoor Temperature Transducer with EMC Cable Gland 3 Ktakt / Support Address Phe Fax & Web Technical Support * 1/ /10/0817
2 Sicherheit und Schutzmaßnahmen Maßzeichnung / Dimensi Drawing 65! den. PG11 / SW22 16,5 schlossen. 47 Ø 4, ,5 1 Safety and Security Precautis Maßzeichnung / Dimensi Drawing! tutis are to be csidered. tis. Changes in these documents are not allowed. Ø PG11 / SW22 Ø 4, , ,5 2/ /10/0817
3 Maßzeichnung / Dimensi Drawing Schaltbild / Cnecti Diagram M16x1,5 / SW20 I-Versi U-Versi 64 Ø 4 36 Voltage Supply SPS Ctroller UB Out UB: V DC Out: 4-20 ma Offset Pt 100 Voltage Supply SPS Ctroller UB GND Out UB: 24 V AC/DC Out: 0-10 V Offset Pt ,5 Achtung: Bei Parallebetrieb mit 24 V AC Versorgung, ist der phasengleiche Anschluss aller Geräte zwingend notwendig (Kurzschlussgefahr)! Attenti: In parallel operati by a 24 V AC supply is the in-phase cnecti of all devices necessary (short-circuit danger)! Schaltbild / Cnecti Diagram Gerätekfigurati / Device Cfigurati,,, Auswahl Messbereich Measurement Range Optis I-Versi I-Versi / U-Versi C C C C C C C C Belegung bei einem 8-fach DIP-Schalter Assignment with a 8-fold DIP-switch Schaltungsart Circuit type Leiter 4-wire 3-Leiter 3-wire 2-Leiter 2-wire 1: UB 15-36v DC 2: TEMP mA Offset UB TEMP 1 2 Rel1 Rel2 NC NO NC NO : UB 15-36v DC 2: TEMP mA 3: opt. GND for DBL Offset Rel1 Rel2 UB TEMP DBL NC NO NC NO : UB 24V AC/DC 2: GND 3: TEMP V Offset Rel1 Rel2 UB GND TEMP. NC NO NC NO C C C C C C C C Belegung bei einem 6-fach DIP-Schalter Assignment with a 6-fold DIP-switch 5 6 Schaltungsart Circuit type Leiter 4-wire 3-Leiter 3-wire 2-Leiter 2-wire Offset Temperatur Offset Temperature ±0 K ±0 K -5 K 5 K -10 K 10 K MR > K 3/ /10/0817
4 -Einstellungen / Settings -Einstellungen / Settings informati informati output signal screen offset screen relay screen output offset relay display in operati main menu value with >UP< and >DOWN< settings settings display settings display directi display ctrast >DOWN< to enter display backlight other settings min / max interval for no deleti >UP< for deleti MIN/MAX measured values other settings display settings DISPLAY directi DISPLAY ctrast DISPLAY backlight min /max MIN/MAX measuring values hrough main menu Bestätigen durch informati Bestätigen durch output signal screen relay screen settings Bestätigen durch settings directi Setting of display directi turnable in 90 steps. The arrow shows the ed directi directi background lighting settings value with >UP< and >DOWN< Free prog range Modus* display mode free prog display mode MIN/MAX measuring values interval Einstellung des Intervalls Setting of the interval Modus / display mode Einstellung der Messwertanzeige im Betriebszustand, z.b. beide Messwerte gross, Messwert 1 gross relay histersis relay hysteresis Setting of the relay hysteresis freely programmable measuring range Depending device type relay hysteresis 4/ /10/0817
5 Anwendungen Aussentemperatur-Messumformer und wandelt diesen Messwert in ein lineares Ausgangssignal 0-10 V bzw ma um. - lung zu vermeiden ist. Aussentemperatur-Messumformer mit Hülse wandelt diesen Messwert in ein lineares Ausgangssignal 0-10 V bzw ma um. - vermeiden ist. Aussentemperatur-Messumformer mit EMV-Verschraubung - Sneneinstrahlung zu vermeiden ist. Technische Daten Messbereichsauswahl C, C, C, C, C, C, C, C, C, C, C, C, C, C, C, C ±0,2 K max. ±1,5% Spanne Pt100 DIN EN Kl. B Gehäuse PG11-Verschraubung mit Zugentlastung - x 45 mm C C Applicatis Outdoor Temperature Transducer - - Outdoor Temperature Transducer with Sleeve - - Outdoor Temperature Transducer with EMC Cable Gland - - Specificatis C, C, C, C, C, C, C, C, C, C, C, C, C, C, C, C ±0,2 K max. ±1,5% Span Pt100 DIN EN Cl. B C 5/ /10/0817
6 Technische Daten Messbereichsauswahl Gehäuse C, C, C, C, C, C, C, C, C, C, C, C, C, C, C, C ±0,2 K max. ±1,5% Spanne Pt100 DIN EN Kl. B Verschraubung M16x1,5 mit Zugentlastung und EMV-Erdung C Specificatis C, C, C, C, C, C, C, C, C, C, C, C, C, C, C, C ±0,2 K max. ±1,5% Span Pt100 DIN EN Cl. B C 6/ /10/0817
Display-Einstellungen / Display Settings. Kontakt / Support * RAFT/A
Display-Einstellungen / Display Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Shows the measured MIN/MAX values of the interval Deleti of the MIN/MAX measuring values through >UP
MehrKontakt / Support * BHA/A
D GB Bewegungs-/Helligkeitsfühler mit Infrarot und Fotodiode Motion / Brightness Probe with Infrared and Photodiode Bewegungs-/Helligkeitsfühler mit Infrarot und Fotodiode Motion / Brightness Probe with
MehrKM/E KSM/E KTM/E. Kontakt / Support. Phone Fax & Web
-Einstellungen / Settings D GB MIN/MAX measuring values Anzeige der im Intervall gemessenen min/max Werte Löschen der MIN/MAX Messwerte mit >UP
MehrRRF/A RRFT/A. Kontakt / Support. Phone Fax & Web
Display-Einstellungen / Display Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Anzeige der im Intervall gemessenen min/max Werte Löschen der MIN/MAX Messwerte mit >UP
MehrCO2-K/A CO2T-K/A. Kontakt / Support. Phone Fax & Web
Display-Einstellungen / Display Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Anzeige der im Intervall gemessenen min/max Werte Löschen der MIN/MAX Messwerte mit >UP
MehrKL/A KLT/A RLU/A. Kontakt / Support. Phone Fax & Web
Display-Einstellungen / Display Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Anzeige der im Intervall gemessenen min/max Werte Löschen der MIN/MAX Messwerte mit >UP
MehrRAFTP/A RKFTP/A. Kontakt / Support. Address. Roethensteig 11. Phone. Fax. & Web
Display-Einstellungen / Display Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Shows the measured MIN/MAX values of the interval Deletion of the MIN/MAX measuring values through >UP
MehrRRFTP/A RRFTP(P)/A. Kontakt / Support. Phone Fax & Web
Display-Einstellungen / Display Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Anzeige der im Intervall gemessenen min/max Werte Löschen der MIN/MAX Messwerte mit >UP
MehrRAF/M RKF/M TW/A. Kontakt / Support. Phone Fax & Web
-Einstellungen / Settings D GB MIN / MAX Messwerte / MIN/MAX measuring values Anzeige der im Intervall gemessenen min/max Werte Löschen der MIN/MAX Messwerte mit >UP
MehrNTC 8kOhm EF5/E EF6/E EF7/E EF8/E. Kontakt / Support LM235Z. 10kPRE. Phone Fax
Widerstandskennlinien / Resistance Characteristics Temp. Pt00 Pt500 Pt000 Ni000 Ni000 TK5000 kohm,8kohm kohm kohm 5kOhm 8kOhm 0kOhm C Ohm Ohm Ohm Ohm Ohm Ohm Ohm Ohm Ohm Ohm kohm kohm 50,00 80, 40,55 80,0
MehrR&R. Ges. für Rationalisierung und Rechentechnik mbh. R&R RR-P-508 / ST106-EX1 motor-control unit
R&R R&R RR-P-08 / ST06-EX motor-control unit housing wxhxd weight application power supply aluminum anodized approx. 6 x 8 x 8 mm housing similar to ST0 drawing DNR967 approx. 80 g motor desk control unit
MehrTechnische Daten Technical data
Technische Technical PLVario-NET E3010000 PLVario-NET E3010001 PLVario-NET/MBUS E3010002 PLVario-NET/MODBUS/RTU E3010003 PLVario-NET/AE E3010004 PLVario-NET/AE/MBUS E3010005 PLVario-NET/AE/MODBUS/RTU bus
MehrInduktive Näherungsschalter
www.ietz-sensortechnik.de support@ietz-sensortechnik.de Phone: +49(0)6252 94299-0 atenblatt INS-HL-01 Hochleistungsprogramm www.ietz-sensortechnik.de support@ietz-sensortechnik.de Phone: +49(0)6252 94299-0
MehrABB i-bus EIB. EIB Power Supply Units
ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!
MehrTECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor
TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,
MehrLORENZ MESSTECHNIK GmbH
DMS- Messverstärker - SG Measuring Amplifier / 2S Zum Anschluss von bis zu 4 350 Ω- Wägezellen 4- oder 6- Leitertechnik ±10 Vdc oder 0-10 Vdc und 4-20 ma Analogausgang Kontrollsignal für die Kalibrierung
MehrTECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor
TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,
MehrSchutzart IP 20 protection degree IP 20 18
MODUL L 196 Pendelleuchte / suspended luminaire MONTAGE / MOUNTING 010-614. 009-282. 010-095 24 V DC / 40 W 010-613. 009-281. 010-094 24 V DC / 45 W Schutzart IP 20 protection degree IP 20 18 max. 1500
MehrTechnisches Datenblatt Technical Data Sheet 3160-00-00.73A4B. Signalwandler für 4 analoge Eingangssignale 4-20mA auf CAN
Seite/Page 1 von/of 5 MultiXtend CAN 3160-00-00.73A4B Signalwandler für 4 analoge Eingangssignale 4-20mA auf CAN Signal converter for four Thermocouple Type J converting to CAN-Bus Beschreibung Description
MehrDC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC
AC-RIDER 80VA WWW.AC-RIDER.COM TÜV Rheinland geprüfte Sicherheit Besondere Merkmale Features 12 VDC Eingang 12 VDC input Hoher Wirkungsgrad High efficiency Überlast / Kurzschlußfest Overload / Short-circuit
MehrSchutzart IP 20 protection degree IP 20 18
MODUL L 196 Pendelleuchte / suspended luminaire MONTAGE / MOUNTING 010-614. 009-282. 010-095 direktstrahlend / direct beam 010-613. 009-281. 010-094 mit Indirektlichtanteil / with indirect light component
MehrDIGICONTROL- Gerätedatenblatt F-KCO2T1 2-Strahlverfahren, (nicht-dispersive Infrarot Technologie) NDIR
DIGICONTROL- Gerätedatenblatt F-KCO2T1 www.gfr.de [81221] Kategorie: Feldgeräte - Sensoren CO2- und Temperatur-Messumformer für Kanalmontage DIGICONTROL F-KCO2T1 Anwendung Der Messumformer F-KCO2T1 ist
Mehr0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
Mehr[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...
DIGICONTROL- Gerätedatenblatt F-SPT-U www.gfr.de [82252] Kategorie: Sensoren und Wächter Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... Anwendung Der Druckmessumformer F-SPT-U...
MehrM12 Verteilerinsel / M12 Splitter box
Serie / Series VER 4-1 Technische Daten Technical data Norm Kabel ohne mit Standard Cable without with Polzahl Kontaktanforderung IEC 947-5-2 4/5 No. of contacts Contact configuration IEC 947-5-2 4/5 Verschmutzungsgrad
MehrOverview thermostat/ temperature controller
Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:
Mehr11Winkel + Flansche. Angles + flanges. Winkel + Flansche/Angles + flanges 401
11Winkel + Flansche Angles + flanges Winkel + Flansche/Angles + flanges 401 Sicher um die Ecke Turning the corner safely 1 2 Flanschseite mit O-Ring Flange view with o-ring UNI Kabelverschraubungswinkel
MehrDistance sensor. Sn = 0,2 6 m
Sn = 0,2 6 m + Analogausgang + analogue output, Sn = 0,2 6 m für Reflektor mit Analogausgang for use with reflector with analogue output Sn = 0,2 30 m Schaltabstand Operating distance Funktion Operating
MehrAGRO Kombi-Schlauchverschraubung aus Messing AGRO Combination conduit glands nickel-plated brass
AGRO Kombi-Schlauchverschraubung aus Messing AGRO Combination conduit glands nickel-plated brass AGRO Kombi-Schlauchverschraubungen sind eine optimale Lösung, wenn Sie Kabel in einem Schutzschlauch in
MehrBedienungsanleitung. Operating instruction. Optical Angle Encoder FOS-IAE2CT01-DT
Bedienungsanleitung Operating instruction April 00 Seite/page 1/7 Anschlußbelegung Connecting Scheme Pin 1 3 Signal +VSupply GND PE Pin 7 Signal LED Trig. High temperature-silicon rubbercable: Cable: silicon
MehrInductive proximity switch
3RG4070-0CD00-PF NO and NC / Schließer und Öffner 3RG4070-3CD00-PF NO and NC / Schließer und Offner 3RG4070-7CD0-PF NO and NC Schließer und Öffner 3RG4070-7CD0-PF NO and NC Schließer und Öffner Cable /
MehrAGRO Kombi-Schlauchverschraubung aus Messing UKAPITEL_SubTitel. AGRO Combination conduit glands nickel-plated brass
UKAPITEL_Titel AGRO Kombi-Schlauchverschraubung aus Messing UKAPITEL_SubTitel AGRO Combination conduit glands nickel-plated brass AGRO Kombi-Schlauchverschraubungen sind eine optimale Kombination, wenn
MehrPeakTech Zeitprogramm erstellen über Excel - Beispiel / Timed programs with Excel Example
PeakTech 6180 Zeitprogramm erstellen über Excel - Beispiel / Timed programs with Excel Example 1. Excel Datei erstellen / Create Excel file Öffnen Sie Excel und erstellen eine xls-datei unter einem beliebigen
MehrBetriebsanleitung/ Operating instructions. EGA/PC-Interface-2 EGA/PC-Interface Anschlussbox 4-fach
Betriebsanleitung/ Operating instructions EGA/PC-Interface Anschlussbox 4-fach EGA/PC-Interface Connectionbox fourfold Zielgruppe: Elektrofachkräfte Target group: Skilled electricians 400 71 860 070 Inhaltsverzeichnis
MehrLED Treiber: Anschlussschemata LED driver: connection diagrams
Treiber: Anschlussschemata driver: connection diagrams TCI DC MAXI JOLLY DALI für 18W (Konstantstromversorgung), 500mA, dimmbar via Taster (Push) / 1-10V / DALI 6Z1851 Sicherheitshinweise Montagehinweise
MehrLORENZ MESSTECHNIK GmbH
DR-2112, DR-2112-R DR-2412, DR-2412-R Drehmomentsensor, rotierend Torque Sensor, rotating Drehmomentsensor, rotierend Torque Sensor, rotating Nenndrehmoment von 0,1 N m... 20000 N m - Nominal torque from
MehrDas mikroprozessorgesteuerte CO 2 Messgerät dient zur Erfassung des CO 2 -Gehaltes der Luft im Bereich bis 2.000 5.000-10.000 ppm, sowie der Temperatur und Luftfeuchte. Die Messsignale werden durch eine
MehrDIGICONTROL- Gerätedatenblatt R-RTS-T 0,14-2,5mm², über Schraubklemmen auf Platine
DIGICONTROL- Gerätedatenblatt R-RTS-T www.gfr.de [82150] Kategorie: Sensoren - Wächter Raumtemperaturregler DIGICONTROL R-RTS-T Anwendung Einstufiger, mechanischer Einzelraumregler, Bi-Metalltechnik, RTS/T
MehrF = Isolator / insulator B = Stuetzhuelse / support sleeve
without written authority from the proprietor Property of D B C G F E = Kabel / cable F = Isolator / insulator B = Stuetzhuelse / support sleeve G = Deckel / cover C = Innenleiter lang / long center contact
MehrWinkel + Flansche 9Angles + Flanges
Winkel + Flansche 9Angles + Flanges Winkel + Flansche/Angels + Flanges 367 Damit es sicher um die Ecke geht Turning the corner safely 1 2 368 Winkel + Flansche/Angels + Flanges Praktische Winkelverschraubungen
MehrElectrical testing of Bosch common rail solenoid valve (MV) injectors
Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445
MehrCL I IP20. 9MX056 MDU-PWR Starter Set/Extension Set. Mounting instructions. New Installation/Neuinstallation. 9MX056 MDU-PWR Starter Set
9MX0 MDU-PWR Starter Set/Extension Set Mounting instructions IP0 CL I a New Installation/Neuinstallation 9MX0 MDU-PWR Starter Set Page/Seite b Retrofit/Nachrüstung 9MX0 MDU-PWR Starter Set Electrical connection
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN
MehrStratos Pro Series. Type A201X-*-0-T6 Type A201B-*-0-T6.
Stratos Pro Series Type A201X-*-0-T6 Type A201B-*-0-T6 Supplement to the Stratos Pro Series Documentation Ergänzung zur Dokumentation der Stratos Pro Serie www.knick.de Measuring Channels MSPH Memosens
MehrTypenreihe GH Lifting Solenoids
Hubmagnete Lifting Solenoids Bauart Hubmagnete der Reihe GH können mit Durchmessern zwischen 5 mm und 65 mm und mit Hublängen von 8 bis 60 mm gefertigt werden. Serien mäßig wer den sie mit Wellenenden
MehrIDG. Drehzahlsensor / Speed Sensor
Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor
MehrDATENBLATT / DATASHEET
DATENBLATT / DATASHEET AEQUILUX DMX PLAYER 1024 / 2048 Abb. Ähnlich Illustration similar BESCHREIBUNG / DESCRIPTION Der AEQUILUX DMX Player dient zur Lichtsteuerung des AEQUILUX Systems. Das Gerät kann
MehrDach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE
Dach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE 4-8 Optimale Luftführung im Schaltschrank Montage und Filterwechsel ohne Werkzeug Gleiche e wie Filterlüfter LV Geringe Einbautiefe
MehrReflector Type STANDARD: Reflector Type CUSTOM:
options rot red blau blue grün green weiß (5600K) white warmweiß (3500K) warmwhite ultraweiß (6500K) ultrawhite RGB (nicht für Komplettlösungen verfügbar) RGB (not available for assembled solution) Ø 5
MehrElectrical testing of Bosch common rail piezo injectors
Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid
MehrLED Treiber: Anschlussschemata LED driver: connection diagrams
ED Treiber: Anschlussschemata ED driver: connection diagrams TCI DC JOY MD für 18W ED (Konstantstromversorgung), 500mA, dimmbar via Phasenabschnittsdimmer / Taster (Push) 6Z 18 50 Sicherheitshinweise Montagehinweise
MehrHochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung
Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung High Voltage measurement device HV3000 AC / DC / Impulse H+H High Voltage Technology www.hundh-mk.com Hochspannungsmessgerät typ HV3000
MehrPt100 Elektronischer Temperaturschalter mit LED-Anzeige. Beschreibung
Pt100 Elektronischer Temperaturschalter mit LED-Anzeige Mit zwei programmierbaren Schaltausgängen oder mit einem programmierbaren Schaltausgang und einem programmierbaren Analogausgang Typ: 7680, 7690
MehrWAM 235 Analysemessgerät mit Loggerfunktion WAM 235 Analysis instrument with logger function
WAM 235 Analysemessgerät mit Loggerfunktion WAM 235 Analysis instrument with logger function WAM 235 Einsatzprofil Das ideale Handmessgerät zur Messung von ph, Salzgehalt, ORP, CD, TDS, DO und Temperatur
MehrLED Treiber: Anschlussschemata LED driver: connection diagrams
ED Treiber: Anschlussschemata ED driver: connection diagrams TCI DC JOY MD für 18W ED (Konstantstromversorgung), 500mA, dimmbar via Phasenabschnittsdimmer / Taster (Push) 6Z 18 50 Sicherheitshinweise Montagehinweise
MehrTechnical Data: Spezial-Steckanschluss (Bosch) Special push-on connector (Bosch)
Temperatursensor mit Warnkontakt (über Masse) Temperature Sensor with Warning Contact (common ground) Technische Daten: Ausführung: Heißleiter (NTC) Nennspannung: 6V bis 24V Temperaturangleichzeit: Min.
MehrFÜLLSTANDSMESSTECHNIK LEVEL MEASUREMENT PRODUKTÜBERSICHT PRODUCT OVERVIEW
FÜLLSTANDSMESSTECHNIK LEVEL MEASUREMENT PRODUKTÜBERSICHT PRODUCT OVERVIEW Schwimmerschalter Float Switches Schwimmerschalter gerade und abgewinkelt PVC, PP, PVDF, VA, MS G1/8" bis G1", Rund- und Ovalflansch
MehrA04 Tel. +49 (0)7081 / Fax +49 (0)7081 /
Hausanschlussverstärker Die HG-Verstärker-Serie bietet Hausanschluss- und Hausverteil-Verstärker in bester POLYTRON-Qualität mit einem bis 1 GHz. Zuverlässige Komponenten und hochwertige Gehäuse untermauern
MehrCertificate of conformity Generating unit, NS-protection
Applicant: Product: Certificate of conformity Generating unit, NS-protection Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with
Mehr2/2-way solenoid valve - Type 218
- direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrTechnisches Datenblatt Technical Data Sheet. Drehzahlsensoren / Speed Sensors 1 Kanal Hall M14 LD Familie 1 Channel Hall M14 LD Type
Drehzahlsensoren / Speed Sensors 1 Kanal Hall M14 LD Familie 1 Channel Hall M14 LD Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -25 +85 C Data summary Power
MehrAKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS
K la vi er l ac ko p tik AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS ZA 8970 DRUCKS0682.indd 1 05.09.12 15:15 VerpAckunGsinhAlT UKW / UHF / VHF Flachantenne
MehrU7. UNI Mehrfach Kabelverschraubungen U7. UNI Multiple Glands
Abb. 1 Fig. 1 Verschraubungskörper Gland body Abb. 2 Fig. 2 Werkstoff Farbe Temp.-bereich min./max. Bestellschlüssel Material Colour Temp.range min./max. supplement Ms, vernickelt d Brass, nickel plated
Mehr~XECRO. sensing ahead NPN PNP 1/+ 1/+ NPN 4/S 4/S PNP. Data sheets are available on
~XECRO sensing ahead Benefits: Fully embedded amplifier Very short housings also in the Advanced Sensing Range Class Stainless steel housings, potted with epoxy and fiber-glass reinforced substrates or
MehrLORENZ MESSTECHNIK GmbH
LRENZ MESSTECHNIK GmbH 0772 /70-0 Fax 0772 /70-22 Berührungsloser Drehmoment-Messflansch, rotierend Contactless Torque Measuring Flange, rotating DR-200 Nenndrehmoment von 0 N m... 000 N m Nominal torque
Mehr~XECRO. Vorteile: Weite Schaltabstände Durchgängiges PTFE-Gehäuse PTFE-gekapselte Schaltanzeige-LED PTFE-gekapseltes Trim-Potentiometer.
~XECRO sensing ahead Benefits: Large sensing distances Housing made of one continuous piece of encapsulated switching indicator encapsulated trim potentiometer Vorteile: Weite Schaltabstände Durchgängiges
MehrTaster LDT, Schalter LDS Switches in momentary action LDT, and latching action LDS
Taster LDT, LDS Switches in momentary action LDT, and latching action LDS Aufbau Construction Frontplattenmontage Frontpanel mounting Abmessungen Dimensions Anschlussbelegung Wiring diagram Schaltsymbol
MehrEINSATZHINWEISE LKM121
Web: www.lkmelectronic.de Mail: info@lkmelectronic.de EINSATZHINWEISE LKM2 Galvanisch getrennter programmierbarer 2-Draht Transmitter LKM2 für Widerstandssensoren und Thermoelemente Der Messumformer wird
MehrProduktname Product name: ANSMANN Working lamp 4. Version Change Date Name
Produktname Product name: ANSMANN Working lamp 4 Artikelnummer Part Number: 1600-0163-520 Anfragenummer Inquiry Number: AN201418 Ersteller / Datum Creator / Date: LHE / 07.12.2016 Version Change Date Name
MehrEMCO Installationsanleitung / Installation instructions
EMCO Installationsanleitung / Installation instructions Installationsanleitung Installation instructions Digitalanzeige digital display C40, FB450 L, FB600 L, EM 14D/17D/20D Ausgabe / Edition B 2012-03
MehrLORENZ MESSTECHNIK GmbH
LORNZ MSSTHNIK GmbH DR-2212, DR-2212-R DR-2512, DR-2512-R Drehmomentsensor, rotierend Torque Sensor, rotating Drehmomentsensor, rotierend Torque Sensor, rotating Nenndrehmoment von 0,1 N m... 20000 N m
MehrNE-MA. Druckschalter für Kompressoren Pressure Switches for Air Compressors
NE-MA Druckschalter für Kompressoren Pressure Switches for Air Compressors 4 NE-MA und Xcon Joint Venture des Erfolgs Für Sie haben wir unsere Kräfte gebündelt; Sie dürfen bestmöglichen Service, bestmögliche
MehrTemperatursensor 1polig über Masse. Temperatur Sensor 1-pole common ground. Betriebssystem. switching on power supply
Temperatursensor 1polig über Masse Temperatur Sensor 1-pole common ground Technische Daten: Ausführung: Nennspannung: Temperaturangleichzeit: Anschlussart / Type of connection: A 1polig über Masse 1-pole
MehrWestenberg Wind Tunnels
MiniAir20 Hand measurement device for flow, humidity and temperature The hand measurement device MiniAir20 is used for the acquisition of temperature, relative humidity, revolution and flow velocity such
MehrMantelthermoelemente. Mineral Insulated Thermocouples. Technische Daten Technical Data. Beschreibung Description
Thermocouples NiCr-Ni, Typ K NiCr-Ni, Type K eschreibung Typ K mit freien Enden isoliert verschweißt Thermocouples Type K with open ends IEC 584-200 +1100 C 50 1,0 K-O363 0050-10 10,00 1,5 K-O363 0050-15
Mehri500 Sicherheitsmodul I5MASA000 I5MASA000 safety module Montageanleitung Mounting Instructions
i500 Sicherheitsmodul I5MASA000 Montageanleitung I5MASA000 safety module Mounting Instructions Allgemeines Erst lesen, dann beginnen 1 1 Allgemeines 1.1 Erst lesen, dann beginnen Lesen Sie vor der Installation
MehrCalibration Certificate
Gegenstand Object Hersteller Manufacturer Typ Type description Serien Nr. Serial no. Inventar Nr. Inventory no. Prüfmittel Nr. Test equipment no. Equipment Nr. Equipment no. Standort Location Auftraggeber
MehrELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary
MehrB/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T
Startfolie B/S/H/ 1 Product division Event Location Refrigeration Side by Side USA B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T 2 Side-by-Side Appliances Models: Bosch Siemens KAN 56V** KAN58A** KA58NA**with
MehrInkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung
Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe
MehrP A max. 100bar A P max. 16bar
1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design
MehrZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.
ZU 0859 Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H www.knick.de Bauart und Funktion Der Endlagenschalter ZU 0859 wandelt die pneumatischen Endlagen signale,
Mehr25W - 750W EINBAUNETZGERÄTE / BUILT-IN POWER SUPPLIES
50W 75W 100W 200W 500W 750W Weitbereichseingang 85...264V AC mit aktiver PFC* Weiteingangsbereich 120...370V Hoher bis 90% Einschaltstrombegrenzung Ausgangsleistungen: 25W bis 750W en: 3.3V, 5V, 7.5V,
MehrDrucksensor (1polig über Masse) Pressure Sensor (1-pole common ground) G (Sensor) Nennspannung: 6V bis 24V Verlustleistung: < 250 mw;
Drucksensor (1polig über Masse) Pressure Sensor (1-pole common ground) Technische Daten: Nennspannung: 6V bis 24V Verlustleistung: < 250 mw; Mess-Strom: > 20 ma Betriebstemperatur: 25 C bis + 100 C Widerstandsbereich:
MehrTechnisches Datenblatt WIE Vorortwandler mit Schnittstelle zertifiziert gemäß DIN EN ISO 9001
www.kemkueppers.com info@kemkueppers.com Technisches Datenblatt WIE Vorortwandler mit Schnittstelle zertifiziert gemäß DIN EN ISO 9001 2 WIE Vorortwandler mit Schnittstelle Anwendung Der Vorortwandler
MehrDatenblatt / Data sheet
Seite/Page 1/5 Abbildungen / Illustration Maßzeichnung / Dimensions Produktbeschreibung Product specification Kompaktes, steckbares Relais für den industriellen Einsatz. Compact, pluggable relay for industrial
Mehrdiameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
Mehr+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W
Kraftvoll bis 200 W + Powerful up to 200 W + + Kleine Bauform Small size Betriebsanzeige über LED und Meldekontakt Status LED and signal contact Zuverlässig entkeimen. Reliable desinfection. Linear V UV
Mehrdiameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrRosenberger Hochfrequenztechnik---
A B ohne Sekundärsicherung without secondary Lock C 1 mit Sekundärsicherung with secondary Lock A = Kabel / cable C = Stützhülse / support sleeve = Plastik Gehäuse / plastic housing B = Innenleiter / centre
MehrElectrical testing of Bosch common rail Injectors
Electrical testing of Bosch common rail Injectors Contents: 1. Adapter cable for Hybridtester FSA 050 (article number 0 684 010 050 / 1 687 023 571) 2. Electrical testing of Bosch common rail solenoid
MehrM9 Steckverbinder IP40 M9 connectors IP40
BF-C BF-B BF-A / M M-US M-T M-S M-D M-B Verteiler VL M-A M M RD0 RD M Bajonett M M IP M IP0 PP IP NCC Bajonett SI IP M9 IP M9 IP0 PP IP MPP IP Bajonett SI IP SI IP0 M9 Steckverbinder IP0 M9 connectors
MehrPMD200WFB DC/DC-Wandler Watt DC/DC Converter Watts. Wirkungsgrad bis 85 % Efficiency up to 85 % Eingangsbereich 2:1 Input Range 2:1
MTM Power Messtechnik Mellenbach GmbH Fürstenbergerstr. 143 D-60322 Frankfurt/Main Tel.: +49-(0)69-1426 0 Fax: +49-(0)69-1426 10 www.mtm-power.com info@mtm-power.com Eingangsbereich 2:1 Input Range 2:1
MehrTechnical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung
Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung 4...7 V 5 V *) Rated Current Nennstrom < 50 ma Sound Output [SPL]at 10 cm Lautstärke[Schalldruckpegel]
Mehr