NetDCU6. Start Interface. Version 1.01 Date: (c) by F & S Elektronik Systeme GmbH 2005
|
|
- Katrin Gerstle
- vor 6 Jahren
- Abrufe
Transkript
1 NetDCU6 Start Interface Version 1.01 Date: (c) by F & S Elektronik Systeme GmbH 2005 F & S Elektronik Systeme GmbH Untere Waldplätze 23 D Stuttgart Tel.: (+49)(0)711/ Fax: (+49)(0)711/
2
3 Delivery Components delivered by Start Interface ensure the proper start up and facilitate software development with NetDCU6. Included Components are listed in Table 1. Additionally a stable power supply 5V/2A and confection of display cable are necessary for the start up. Table 1:Delivery components Quanitity Component 1 Adapter NetDCU6-Start Interface 1 Ethernet cable Cat 5 Blue 1 Ethernet cable Cat 5 Grey :crossover 1 One side manufactured display cable 3 Null modem cable Page 1
4 Start Up NetDCU6 Figure 1 shows the Start Interface for NetDCU6 with the position and description of connectors. Serial RS232 Interface 1 10/100 MBit Ethernet 2 x USB (Host) 1 x USB (Device) Serial RS232 Interface 3 CFL-Power V BAT +5V Ground Analog Input Ports Touchpanel Interface Serial RS232 Interface 2 I/O Interface (Keyboard) Stereo Speaker (Line Out) Microphone CAN2.0 Interface USB Selection (V) BAT Audio In (Line In) Figure 1: Start Interface without NetDCU6. Page 2
5 Configured Connectors Power Supply For operating NetDCU6 power supply of +5V has to be connected as shown in figure 1. The optional voltages Vbat and CFL-Power could be connected to NetDCU6. On Vbat a battery ( V) could be connected to buffer NetDCU6 if power supply switched off (-> Backup Battery NetDCU6). The connection Vcfl could be used to make voltage for CFL- converter (max 12V/2A) switchable and available on display connector of NetDCU6 (see HWdocumentation NetDCU6). Backup Battery NetDCU6 Standardmäßig ist auf dem Startinterface für die NetDCU6 eine 3V Litium-Batterie vorhanden. Zum Betrieb mit der NetDCU6 muss diese noch aktiviert werden. Dazu wird der Schalter 4 (siehe Abb. 1 USB Selection) auf ON gestellt. Damit wird die Batterie auf den V BAT Input der NetDCU6 geschaltet. ON OFF Figure 2: Aktivierung der Batterie Soll die Batteriepufferung über den externen Input V BAT erfolgen (siehe Abb. 1 Schraubklemmen), so muss die Page 3
6 Batterie auf dem Startinterface deaktiviert und die Lötbrücke R12 eingelötet werden. ON OFF Figure 3: Deaktivierung der Batterie R12 0R00 Figure 4: Position Lötbrücke R12 Page 4
7 Status Indicators NetDCU6 has five LED status indicators (see figure 2). Table 2 describes the correlation between LED status indicator and status. Table 2: Status indicators of NetDCU6 LED Status Description 1 RUN Power PC in Run-Mode 2 STATUS Status massage (see SW- Documentation) 3 LINK Ethernet: Connection online 4 TRAFFIC Ethernet: Traffic 5 PCMCIA PCMCIA: Slot active power Page 5
8 Figure 5: Status indicators of NetDCU6 ETH1 ETH2 PCM STA RUN LED5 LED4 LED3 LED2 LED1 Ethernet Interface For network integration of NetDCU6 two Ethernet cable Cat5 are included in delivery. To connect NetDCU6 direct with an other computer it is required to use the (gray) crossover Ethernet cable. Should the Ethernet connection be established by using a hub or switch their configuration determinates choice of the cable. The usage of the proper cable is signalized by the LINK-LED ( table 2 and figure 5).The pin assignment is shown in figure 6 and table 3. Page 6
9 Figure 6: Ethernet connector RJ45 Table 3: Pin assignment Ethernet Interface PIN Signal Function 1 TxD2 Transmitted Data 2 TxD1 Transmitted Data 3 RxD2 Received Data 4 NC - 5 NC - 6 RxD1 Received Data 7 NC - 8 NC - Page 7
10 Serial RS232 Interface 1 The serial RS232 interface 1 is connected with connector J2 on NetDCU6. Connect these interface with the desired serial line of the remote PC by using a null modem cable. The pin assignment is shown in figure 4 and table 4. Figure 4: Serial connector HDP-20 of RS232 interface 1 Table 4: Pin assignment of RS232 interface 1 PIN Signal Function 1 NC - 2 RxD Received Data 3 TxD Transmitted Data 4 NC - 5 GND Signal Ground 6 NC - 7 RTS Request To Send 8 CTS Clear To Send 9 NC - Page 8
11 Serial RS232 Interface 2 The serial RS232 interface 2 is connected with connector J5 on NetDCU6. Connect these interface with the desired serial line of the remote PC by using a null modem cable. The pin assignment is shown in figure 5 and table 5. Figure 5: Serial connector HDP-20 of RS232 interface 2 Table 5: Pin assignment of RS232 interface 2 PIN Signal Function 1 NC - 2 RxD Received Data 3 TxD Transmitted Data 4 NC - 5 GND Signal Ground 6 NC - 7 NC - 8 NC - 9 NC - Page 9
12 Serielle RS232-Schnittstelle 3 Die serielle RS232-Schnittstelle 3 ist mit dem Stecker J7 der NetDCU6 verbunden. Diese Schnittstelle wird mit dem beigelegten Nullmodenkabel mit der gewünschten seriellen Schnittstelle des PCs verbunden. Die Anschlussbelegung wird durch Tabelle 6 und Figure 9 beschrieben. Figure 9: serieller Stecker HDP-20 der seriellen RS232- Schnittstelle 3 Tabelle 6: Steckerbelegung der RS232-Schnittstelle 2 PIN Signal Function 1 NC - 2 RxD Received Data 3 TxD Transmitted Data 4 NC - 5 GND Signal Ground 6 NC - 7 NC - 8 NC - 9 NC - Page 10
13 USB Interface NetDCU6 has two USB ports which are aligned with a standard USB connector (Lumberg, ) on Start Interface. At the Start Interface pin 1 of each USB port is assigned by a squared pad and the counting is continuous in each row. The pin assignment is shown in table 7. Figure 10: Dual USB connector USB Port 2 USB Port 1 Table 7: Pin assignment of USB interface PIN Signal Function 1 (5) W USB Power Supply 2 (6) M USB Negative 3 (7) P USB Positive 4 (8) GND Signal Ground Page 11
14 Zusätzlich muss der USB Port 1 als HOST-Port konfiguriert werden. Dies geschieht mittels der Schalter 1 bis 3 (siehe Abb. 1 USB Selection). Figure 11: Configuration USB Port 1 as HOST ON OFF Der USB Port 1 kann auch als USB DEVICE konfiguriert werden. Dazu wird die Einstellung der Schalter 1 bis 3 verändert (siehe Abb. 12). Der Device Port liegt dann auf dem USB Device Stecker (Lumberg, Best.: ). Bitte beachten Sie, dass bei aktiviertem Device Port der Port 1 des USB zweifach Steckers (siehe Abb. 10) nicht benutzt werden darf! Figure 12: Configuration USB Port 1 as DEVICE ON OFF Page 12
15 Figure 13: USB Device connector 2 1 USB Port 1 (Device) 3 4 Table 8: Pin assignment of USB Device connector PIN Signal Function 1 NC - 2 M USB Negative 3 P USB Positive 4 GND Signal Ground Page 13
16 Audio Interface All Audio interfaces on NetDCU6 are aligned to jack chassis sockets on Start Interface (Lumberg, KLBR4, 3.5mm). Matching connectors are available at Lumberg (KLS40) e.g. ( Figure 6 shows the contacting of jack chassis socket. Figure 6: Contacting of jack chassis socket KLBR4 Tables 8-10 shows pin assignment of stereo speaker, microphone und line in channels at connector KLBR4. Table 8: Pin assignment of stereo speaker PIN Signal Function 1 AGND Analog Signal Ground 2 LINEOUT-L Line Out Left Channel 3 LINEOUT-R Line Out Right Channel 4 NC - Page 14
17 Table 9: Pin assignment of microphone PIN Signal Function 1 MICGND Microphone Signal Ground 2 MIC Microphone Input 3 NC - 4 NC - Table 10: Pin assignment of line in channels PIN Signal Function 1 AGND Analog Signal Ground 2 LINEIN-L Line In Left Channel 3 LINEIN-R Line In Left Channel 4 NC - Page 15
18 CAN2.0 Interface Die NetDCU6 wird optional mit einer CAN2.0 Schnittstelle angeboten. Der Schnittstellentreiber (PCA82C250) für den CAN-Bus ist auf dem Starterinterface enthalten (keine galvanische Trennung vorhanden). Herausgeführt wird der CAN-Bus auf einen zweireihigen 10 poligen Anschlussstecker (Rastermaß 2,54mm). Die Zählweise des Steckers wird in Figure 15 gezeigt. Figure 15: Counting of the connector Der CAN-Bus kann mit einem Abschlusswiderstand versehen werden (Standardausführung). Er hat einen Wert von 120 (Bauform: 1206). Wird der Widerstand nicht benötigt, so muss er ausgelötet werden. Tabelle 11 zeigt die Steckerbelegung der CAN2.0 Schnittstelle und in Figure 16 wird die Lage des Steckers sowie des Widerstandes gezeigt. Page 16
19 Table 11: Pin assignment of CAN2.0 interface PIN Signal Function 1 NC - 2 GND Signal Ground 3 CANL CAN-Bus Low 4 CANH CAN-Bus High 5 GND Signal Ground 6 NC - 7 NC - 8 NC - 9 NC - Page 17
20 Figure 16: Position CAN2.0 connector R13/120R Page 18
21 Additional Configurations To use I/O and touch interface as well as analog input ports in the following the pin assignment for these connectors is described. All these connectors are prepared for Two-Row Connectors. Pin 1 is marked by a squared pad. The row with pin 1 contains all odd-numbered pins (1, 3, 5, 7, etc.), and, corresponding to this, the row without pin 1 contains all evennumbered pins (2, 4, 6, 8, etc.). Figure 7 shows an example. Figure 17: Example for counting of connector pins Page 19
22 Parallel I/O Interface Table12: Pin assignment of parallel I/O interface PIN Signal Function I/O 1 GPIO8 Interrupt I/O(*) 2 GPIO7 IO-Port 7 I/O 3 GPIO6 IO-Port 6 I/O 4 GPIO5 IO-Port 5 I/O 5 GPIO4 IO-Port 4 I/O 6 GPIO3 IO-Port 3 I/O 7 GPIO2 IO-Port 2 I/O 8 GPIO1 IO-Port 1 I/O 9 GPIO0 IO-Port 0 I/O 10 GPIO16 IO-Port 16 I/O (*) 11 GPIO17 IO-Port 17 I/O (*) GPIO18 IO-Port 18 I/O (*) GPIO19 IO-Port 19 I/O (*) 16 GND Signal Ground Power 17 KBIN7 Input-Port 7 Input (*) 18 KBIN6 Input-Port 6 Input (*) 19 KBIN5 Input-Port 5 Input (*) Page 20
23 PIN Signal Function I/O 20 KBIN4 Input-Port 4 Input (*) 21 KBIN3 Input-Port 3 Input (*) 22 KBIN2 Input-Port 2 Input (*) 23 KBIN1 Input-Port 1 Input (*) 24 KBIN0 Input-Port 0 Input (*) 25 V CC +5V DC Power 26 V DD +3,3V (0,1A max.) DC Power (*) Remark: I/O pins have a pull-up resistor 4.7k to +3.3V. (- - -) Please note: These pins carry active signals. Any invalid connection of these signals may result in unexpected behavior or even destruction of the component! All input and output levels have to satisfy the LVC standard (3.3V)! Page 21
24 Touch Panel Table 13: Pin assignment Touch Panel PIN Signal Function 1 NC - 2 NC - 3 V CC +5V DC (0,1A max.) 4 GND Signal Ground 5 TOUCH X+ X-Voltage Measurement 6 TOUCH Y+ Y-Voltage Measurement 7 TOUCH X- X-Set Active Measurement 8 TOUCH Y- Y-Set Active Measurement 9 V DD +3,3V DC (max. 0,1A) 10 GND Signal Ground Page 22
25 Analog Input Ports Table 14: Pin assignment for analog input PIN Signal Function 1 V CC +5V DC (0,1A max.) 2 GND Signal Ground 3 AD0 Analog Input 0 (*) 4 AD1 Analog Input 1 (*) 5 AD2 Analog Input 2 (*) (**) 6 AD3 Analog Input 3 (*) (**) 7 V DD +3,3V DC (0,1A max.) 8 GND Signal Ground 9 NC NC 10 NC NC (*) Input voltage: 0V to 7,5V (max. 8V) AD-Converter: 10 Bit resolution, error ±1 LSB 47k Pull Down resistor to GND. (**) Not connected at delivery. NetDCU6 and Starter Interface have to be configured to use this function (-> NetDCU6 Hardware documentation, analog inputs and Figure 18 on the next side). Page 23
26 Figure 18: Configuration AD2/AD3 Ad2 / Ad3 0R00 / 1206 RS232 Interface 3 Page 24
27 Display Connector The display connector is already fixed on the NETDCU6. The proper configuration of the interface is described in the hardware documentation NetDCU6. The cable that is added to the starter kit can be used to make the connection to your display. Pin 1 is marker with an arrow. Take care: before the first start up of display all hard- and software setting for the display must be configured appropriate! Table 15: Pin assignment of display connector PIN Signal Function 1 GND Signal Ground 2 R1 Red Bit 1 3 R0 Red Bit 0 (LSB) 4 G5 Green Bit 5 (MSB) 5 G4 Green Bit 4 6 G3 Green Bit 3 7 G2 Green Bit 2 8 GND Signal Ground 9 B3 Blue Bit 3 10 B2 Blue Bit 2 11 B1 Blue Bit 1 12 B0 Blue Bit 0 (LSB) 13 G1 Green Bit 1 Page 25
28 PIN Signal Function 14 G0 Green Bit 0 (LSB) 15 B5 Blue Bit 5 (MSB) 16 B4 Blue Bit 4 17 GND Signal Ground 18 V EEK V EE /10 19 CLP Data Clock Pulse 20 FRP Frame Impulse 21 M Display Enable Signal 22 LIP Line Impulse 23 DEN Display ON 24 GND Signal Ground 25 V LCD LCD Power +5V (+3,3V) 26 V EE Negative LCD-Contrast Voltage 27 V ADJ Contrast Adjustment 28 GND Signal Ground 29 +V EE Positive LCD-Contrast Voltage 30 V CFL +12V for CFL-Converter 31 R2 Red Bit 2 32 R3 Red Bit 3 33 R4 Red Bit 4 34 R5 Red Bit 5 (MSB) Page 26
29 Parallel System Interface (FS-BUS) The parallel system interface of NetDCU6 is not connected with the Start Interface. It is direct used from NetDCU6 (J4) and is provided with a two row multi point socket connector. The pin assignment is shown in the hardware documentation NetDCU6. Page 27
30 Index Delivery 1 First Run Configured Connectors 3 Inbetriebnahme Konfigurierte Anschlüsse Audio-Schnittstelle 14 CAN2.0-Schnittstelle 16 Ethernetanschluss 6 Serielle RS232-Schnittstelle 1 8 Serielle RS232-Schnittstelle 2 10 Serielle RS232-Schnittstelle 3 9 Statusanzeigen 5 USB-Schnittstelle 11 Weitere Configurationsmöglichkeiten 19 Parallele I/O-Schnittstelle 20 Start up Additional Configurations Analog Input Ports 23 Touch Panel 22 Configured Connectors Backup Battery 3 Power Supply 3 Display Connector 25 Parallel System Interface (FS-Bus 28 Start Up NetDCU6 2 Page 28
Vorläufige Dokumentation
PicoMOD1 Hardware Version 1.00 Datum 27.04.2006 by F & S Elektronik Systeme GmbH 2006 Vorläufige Dokumentation F & S Elektronik Systeme GmbH Untere Waldplätze 23 D-70569 Stuttgart Tel.: 0711/6772240 Fax:
MehrVN7640 FlexRay/CAN/LIN/Ethernet Interface Quick Start Guide. Version 1.1 English/Deutsch
VN7640 FlexRay/CAN/LIN/Ethernet Interface Quick Start Guide Version 1.1 English/Deutsch Quick Start Guide VN7640 ENGLISH 1 ENGLISH 1.1 Installation Step by Step Procedure Please use the drivers from the
MehrPROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module
LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.
MehrAKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS
K la vi er l ac ko p tik AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS ZA 8970 DRUCKS0682.indd 1 05.09.12 15:15 VerpAckunGsinhAlT UKW / UHF / VHF Flachantenne
MehrTube Analyzer LogViewer 2.3
Tube Analyzer LogViewer 2.3 User Manual Stand: 25.9.2015 Seite 1 von 11 Name Company Date Designed by WKS 28.02.2013 1 st Checker 2 nd Checker Version history Version Author Changes Date 1.0 Created 19.06.2015
MehrUNIGATE CL Konfiguration mit WINGATE
UNIGATE CL Konfiguration mit WINGATE - UNIGATE CL Configuration via WINGATE Art.-Nr.: V3928 Deutschmann Automation GmbH & Co. KG Carl-Zeiss-Str. 8 D-65520 Bad Camberg Phone: +49-(0)6434-9433-0 Hotline:
MehrQuick Start Guide. VN8810 Wireless Interface for CAN/LIN/K Line and DoIP Version 1.0 English / Deutsch
Quick Start Guide VN8810 Wireless Interface for CAN/LIN/K Line and DoIP Version 1.0 English / Deutsch ENGLISH Quick Start Guide VN8810 1 ENGLISH 1.1 Installation Please use the drivers from the included
MehrMPC-460. Edition: Mobile Process Computer. Bemerkung/Remark: 1/6. Abmessungen/Dimensions [mm]:
Abmessungen/Dimensions [mm]: Technische Daten/Technical data: Betriebsspannung: Voltage range Stromaufnahme (1) : Current consumption (1) 10 30 V (DC) 340 ma @ 24 V 400 ma @ 12 V Prozessorsystem / Processor
MehrWord-CRM-Upload-Button. User manual
Word-CRM-Upload-Button User manual Word-CRM-Upload for MS CRM 2011 Content 1. Preface... 3 2. Installation... 4 2.1. Requirements... 4 2.1.1. Clients... 4 2.2. Installation guidelines... 5 2.2.1. Client...
MehrVGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016
Overview The Hamburg Süd VGM Web portal is an application that enables you to submit VGM information directly to Hamburg Süd via our e-portal Web page. You can choose to enter VGM information directly,
MehrZusatz zur Betriebsanleitung Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Zusatz zur Betriebsanleitung Addendum to the Operating Instructions Austausch von MOVIGEAR -S01 durch MOVIGEAR -DSC-B Replacing MOVIGEAR
MehrRS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät
Betriebsanleitung RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät ä 2 Operating Instructions RS232 Connection, RXU10 Setting up an RS232 connection
MehrCR2013. CompactModule. E/A-Modul digital und analog für System R 360. CANopen. Schnittstelle. Betriebsspannung V DC.
Steuerungssysteme CR0 60 CompactModule 7 8 E/A-Modul digital und analog für System R 60 6 PWR 8 Schnittstelle Betriebsspannung 0... V DC,7 07 DIA 8, 9 7,, Mx Ausführung Betriebsspannung Stromaufnahme Eingänge
MehrLVDS - Adapter NetDCU-ADP/LVDS1
LVDS - Adapter NetDCU-ADP/LVDS1 Version 1.04 Datum 10.08.2010 by F & S Elektronik Systeme GmbH 2004 F & S Elektronik Systeme GmbH Untere Waldplätze 23 D-70569 Stuttgart Tel.: 0711/6772240 Fax: 0711/6772243
Mehrrot red braun brown rot red RS-8 rot red braun brown R S V~
Kleiner Ring 9 /Germany Phone: 0049 4122 / 977 381 Fax: 0049 4122 / 977 382 Sample connections: Feedback module with integrated detection of occupied tracks for the RS-feedback bus (Lenz Digital plus)
MehrElectrical testing of Bosch common rail piezo injectors
Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid
MehrElectrical tests on Bosch unit injectors
Valid for Bosch unit injectors with order numbers 0 414 700 / 0 414 701 / 0 414 702 Parts Kit Magnet*: - F00H.N37.925 - F00H.N37.933 - F00H.N37.934 * For allocation to the 10-place Bosch order number,
MehrAnschluss Smart Kamera VS-05 Connection Smart Camera VS-05
Anschluss Smart Kamera Connection era Multifunktional Multifunctional HSD 0310.005 www.di-soric.com Pinbelegung USB - seriell / Pin assignment USB - serial RS 232 USB 1 2 6 3 4 Anschlüsse / Connections
MehrBedienungsanleitung / Manual für il-debug_i Interface für den Debugger il_debug
Bedienungsanleitung / Manual für il-debug_i Interface für den Debugger il_debug Ing.Büro Stefan Lehmann Fürstenbergstraße 8a D-77756 Hausach Tel. (07831) 452 Fax (07831) 96428 E-Mail SL@iL-online.de Internet
MehrCameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe
Cameraserver mini commissioning Page 1 Cameraserver - commissioning Contents 1. Plug IN... 3 2. Turn ON... 3 3. Network configuration... 4 4. Client-Installation... 6 4.1 Desktop Client... 6 4.2 Silverlight
MehrUWC 8801 / 8802 / 8803
Wandbedieneinheit Wall Panel UWC 8801 / 8802 / 8803 Bedienungsanleitung User Manual BDA V130601DE UWC 8801 Wandbedieneinheit Anschluss Vor dem Anschluss ist der UMM 8800 unbedingt auszuschalten. Die Übertragung
Mehriid software tools QuickStartGuide iid USB base driver installation
iid software tools QuickStartGuide iid software tools USB base driver installation microsensys Nov 2016 Introduction / Einleitung This document describes in short form installation of the microsensys USB
MehrHow-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens
How-To-Do Hardware Configuration of the CC03 via SIMATIC Manager from Siemens Content Hardware Configuration of the CC03 via SIMATIC Manager from Siemens... 1 1 General... 2 1.1 Information... 2 1.2 Reference...
MehrLAN-Mini/R-485 Handbuch Manual
LAN-Mini/R-485 Handbuch Manual - Konverter - steckbare Schraubklemme - LAN-Kabel - CD - Hutschienenclip Lieferumfang Shipment - converter - pluggable locking ring - LAN-cord - CD - DIN rail clip Optionales
MehrMultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!
MultiPortSwitch VGA Umschalter Version 1.0 As of April 19 th 2004 Subject to change! Document version: Version Date Name Comment 1.00 29.03.2004 J. Klein Compiled Distributed by: idata industrielle Datensysteme
MehrSY-720SC. SCART to HDMI Scaler OPERATION MANUAL
SY-720SC SCART to HDMI Scaler OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 1 4.1 Scart Pinout Configuration 2 5. Connection
MehrVGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016
Overview The Hamburg Süd VGM-Portal is an application which enables to submit VGM information directly to Hamburg Süd via our e-portal web page. You can choose to insert VGM information directly, or download
MehrSchaltungshinweise zum Linux Control System mit DIL/NetPC DNP/7520
Schaltungshinweise zum Linux Control System mit DIL/NetPC DNP/7520 Das Linux Control System ist eine typische Anwendung für das Linux Control Modul DIL/NetPC DNP/7520. Die Abbildung 1 zeigt die Blockschaltung.
MehrCAN-Bus RPM adapter. User Manual Anwender-Beschreibung
CAN-Bus RPM adapter COT02 User Manual Anwender-Beschreibung Stand: 12.02.03 GRABAU Computertechnik GmbH Elsener Str. 30 33102 Paderborn Tel: +49 5251 1367-0 Fax: +49 5251 1367-30 Email: info@grabau.de
MehrQuality control and process tracking. From concept to acceptance.
Quality control and process tracking. From concept to acceptance. EFFICIENT FLEXIBLE INDIVIDUAL Industrial PC PROMINO The PROMINO is a low-cost, high-performance industrial PC available in two versions.
MehrVN p/CAN/GNSS Interface Quick Start Guide. Version 1.0 English/Deutsch
VN4610 802.11p/CAN/GNSS Interface Quick Start Guide Version 1.0 English/Deutsch Quick Start Guide VN4610 ENGLISH 1 ENGLISH 1.1 Important Notes Caution! Do not operate the device without antennas! To avoid
MehrElectrical testing of Bosch common rail solenoid valve (MV) injectors
Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445
MehrUCON/s UCON/s Kurzanleitung Inbetriebnahme
UCON/s UCON/s Kurzanleitung Inbetriebnahme copyright G&D 24/08/2005 Irrum und techn. Änderungen vorbehalten 1. Was Sie zur Installation benötigen - UCON/s - 1:1 belegtes CAT-x Patchkabel - CATPRO2(bei
MehrIR RECEIVER Bedienungsanleitung User s Manual
Bedienungsanleitung User s Manual Die zweite Generation des MBNLED RGB DMX POWER SUPPLY und des MBNLED PRO Controller RGB DMX bieten die Möglichkeit, LED Module über eine Infrarot Fernbedienung zu steuern.
MehrElectrical testing of Bosch common rail Injectors
Electrical testing of Bosch common rail Injectors Contents: 1. Adapter cable for Hybridtester FSA 050 (article number 0 684 010 050 / 1 687 023 571) 2. Electrical testing of Bosch common rail solenoid
Mehr1. Hardware Configuration Hardware-Konfiguration Software-Konfiguration Software Configuration...4
Einzel- und Verbundkonfiguration Stand-alone and Multi-unit Configuration Inhaltsverzeichnis 1. Hardware-Konfiguration... 2 1.1 Netzwerkadressen...2 1.2 Verkabelung...2 Contents 1. Hardware Configuration...2
MehrCABLE TESTER. Manual DN-14003
CABLE TESTER Manual DN-14003 Note: Please read and learn safety instructions before use or maintain the equipment This cable tester can t test any electrified product. 9V reduplicated battery is used in
MehrAnalog GSM-Gateway TRF
Analog GSM-Gateway TRF GSM gateway for voice- or fax transmission 1 2009 com.sat GmbH Kommunikationssysteme Schwetzinger Str. 19 D-68519 Viernheim www.comsat.de Tel: +49-(0)180-3-768837 The connecting
MehrGmbH, Stettiner Str. 38, D-33106 Paderborn
Serial Device Server Der Serial Device Server konvertiert die physikalische Schnittstelle Ethernet 10BaseT zu RS232C und das Protokoll TCP/IP zu dem seriellen V24-Protokoll. Damit können auf einfachste
MehrPoE Kit Mounting Instructions SG/XG 210/230/310/330/430/450
PoE Kit Mounting Instructions PoE Kit Mounting Instructions Please note ÌÌ Before installing/removing any LAN module please make sure that the appliance is powered off and power cables are removed. ÌÌ
MehrR&R. Ges. für Rationalisierung und Rechentechnik mbh. R&R RR-P-508 / ST106-EX1 motor-control unit
R&R R&R RR-P-08 / ST06-EX motor-control unit housing wxhxd weight application power supply aluminum anodized approx. 6 x 8 x 8 mm housing similar to ST0 drawing DNR967 approx. 80 g motor desk control unit
MehrMonitor VIS 3xx Kurzanleitung
Monitor VIS 3xx Kurzanleitung 19.08.08 Art. Nr. 22261 Inhalt: 1. Spezifikationen...2 2. Tastenfunktionen...2 3. Menüführung und Einstellungen...3 Technik nach Maß Wöhler Monitor VIS 3xx 1. Spezifikationen
MehrHow-To-Do. Hardware Configuration of the CPU 317NET with external CPs on the SPEED Bus by SIMATIC Manager from Siemens
How-To-Do Hardware Configuration of the CPU 317NET with external CPs on the SPEED Bus by SIMATIC Manager from Siemens Content Hardware Configuration of the CPU 317NET with external CPs on the SPEED Bus
MehrKonfiguration von eduroam. Configuring eduroam
eduroam Windows 8.1 / 10 Konfiguration von eduroam Configuring eduroam 08.10.2018 kim.uni-hohenheim.de kim@uni-hohenheim.de Wissenschaftliche Einrichtungen und Universitäten bieten einen weltweiten Internetzugang
MehrEthernet Connection Ecograph / Memograph / Energy and Application Manager
Operating Manual Ethernet Connection Ecograph / Memograph / Energy and Application Manager ZBA109R/09/a2/04.08 51002450 MS-Word Ethernet-Verbindung Ecograph/Memograph / RMx 621 Ankopplung eines Eco-/Memograph
MehrTechnisches Datenblatt Technical Data Sheet 3160-00-00.73A4B. Signalwandler für 4 analoge Eingangssignale 4-20mA auf CAN
Seite/Page 1 von/of 5 MultiXtend CAN 3160-00-00.73A4B Signalwandler für 4 analoge Eingangssignale 4-20mA auf CAN Signal converter for four Thermocouple Type J converting to CAN-Bus Beschreibung Description
MehrApplication Note. Import Jinx! Scenes into the DMX-Configurator
Application Note Import Jinx! Scenes into the DMX-Configurator Import Jinx! Scenen into the DMX-Configurator 2 The Freeware Jinx! is an user friendly, well understandable software and furthermore equipped
Mehresense Compatibility Information
esense Compatibility Information Last Update July 2017 ios devices compatible with esense Apple iphone 4S or higher Apple ipad (from 2 nd generation) Apple ipod touch 5 th generation or higher Important
MehrCB RADIO Service Manual AE 6890
CB RADIO Service Manual AE 6890 Downloaded from www.cbradio.nl Technische Mitteilung zu AE 6890 Problem: Bei Montage einer schlecht geerdeten Antenne oder einer Antenne mit schlechtem SWR sehr nahe am
MehrHama GmbH & Co KG Postfach Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/
www.hama.de Hama GmbH & Co KG Postfach 80 86651 Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/502-274 hama@hama.de www.hama.de 00062249-05.05 Multimedia Kit für/for Mercedes Command 2.0 00062249
MehrMagic Figures. We note that in the example magic square the numbers 1 9 are used. All three rows (columns) have equal sum, called the magic number.
Magic Figures Introduction: This lesson builds on ideas from Magic Squares. Students are introduced to a wider collection of Magic Figures and consider constraints on the Magic Number associated with such
MehrTomTom WEBFLEET Tachograph
TomTom WEBFLEET Tachograph Installation TG, 17.06.2013 Terms & Conditions Customers can sign-up for WEBFLEET Tachograph Management using the additional services form. Remote download Price: NAT: 9,90.-/EU:
MehrMontageanleitung zum Einbau und Betrieb der seriellen QUATECH PC-High-Speed Schnittstellenkarte
Montageanleitung zum Einbau und Betrieb der seriellen QUATECH PC-High-Speed Schnittstellenkarte Fitting Instructions for the installation and operation of the QUATECH PC serial high-speed interface card
MehrBedienungsanleitung. Operating Manual. Starter-KIT FIT ) -AED-KIT. A2022-1.0 de/en
Bedienungsanleitung Operating Manual Starter-KIT ) -AE-KIT 2 -AE-KIT 1 Allgemeines as Starter-KIT dient dem Anschluss der (CAN / evicenet) bzw. AE9401A (mit A103C) an einen PC. Es ist nur im Laborbereich
MehrEinbauanleitung Komfort CAN Bus Interface 62240
Einbauanleitung Komfort CAN Bus Interface 62240 Wichtiger Hinweis vor dem Einbau: Bitte beachten Sie generell beim Einbau von elektronischen Baugruppen in Fahrzeugen die Einbaurichtlinien und Garantiebestimmungen
MehrEINBAUHINWEISE INSTALLATION INSTRUCTIONS
EINBAUHINWEISE INSTALLATION INSTRUCTIONS FÜR JEDEN ANSPRUCH DAS RICHTIGE FAHRWERK. KW automotive GmbH Aspachweg 14 74427 Fichtenberg Telefon: +49 7971 9630-0 Telefax: +49 7971 9630-191 www.kwsuspensions.de
MehrUSB -> Seriell Adapterkabel Benutzerhandbuch
USB -> Seriell Adapterkabel Benutzerhandbuch 1. Produkt Eigenschaften 1 2. System Vorraussetzungen 1 3. Treiber Installation (Alle Windows Systeme) 1 4. Den COM Port ändern 2 5. Einstellen eines RS232
MehrDPM_flowcharts.doc Page F-1 of 9 Rüdiger Siol :28
Contents F TOOLS TO SUPPORT THE DOCUMENTATION... F-2 F.1 GRAPHIC SYMBOLS AND THEIR APPLICATION (DIN 66 001)... F-2 F.1.1 Flow of control... F-3 F.1.2 Terminators and connectors... F-4 F.1.3 Lines, arrows
MehrRevision List Referred to on Certificate No.: 01/205/ /15 Product Tested: AZ300 / AZM300
Type designation Description / System Firmware Revision Report-No. Certification status AZ300 AZM300 AZM300AS AZM300AS...P EX AZM300 Sicherheitsschalter AZ300 / Safety switch AZ300 Sicherheitszuhaltung
MehrHama GmbH & Co KG Postfach Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/
www.hama.de Hama GmbH & Co KG Postfach 80 86651 Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/502-274 hama@hama.de www.hama.de 00062248-05.05 Multimedia Kit für/for Audi Naviplus/ VW/Seat/Skoda
MehrAnschluss der NCR PC-8881 Doppelfloppystaton an einen "normalen" Computer (keinen NEC):
Anschluss der NCR PC-8881 Doppelfloppystaton an einen "normalen" Computer (keinen NEC): Durch die Wannenstecker auf der Laufwerksplatine des FD1165A ist die Belegung an der 50pol. Centronics Buchse um
MehrUCON UCON Kurzanleitung Inbetriebnahme
UCON UCON Kurzanleitung Inbetriebnahme copyright G&D 24/08/2005 Irrum und techn. Änderungen vorbehalten 1. Was Sie zur Installation benötigen - UCON - 1:1 belegtes CAT-x Patchkabel - Kaltgerätekabel -
MehrTable of Cont 6. 2 General Information... 4 Purpose...4 Documentation...4 Scope of Supply...5 Technical Data Safety Regulations...
2 General Information........................ 4 Purpose........................................4 Documentation................................4 Scope of Supply................................5 Technical
MehrSnap-in switch for switches PSE, MSM and MCS 30
Product manual Snap-in switch for switches PSE, MSM and MCS 30 CONTENTS 1. PRODUCT DESCRIPTION 2. DATA AND DIMENSIONAL DRAWINGS 2.1. Technical Data 2.2. Dimensions of PSE with a Mounting Diameter 19 mm
MehrPlease do not use in live circuits. When the POWER LED does not light, you must change the battery for testing.
L A N / U S B C A B L E T E S T E R I n s t a l l a t i o n 1 2 9 9 6 4 1. I n t r o d u c t i o n The LAN/USB Cable Tester is designed to easily read the correct cable pin out configuration. The cables
MehrFundamentals of Electrical Engineering 1 Grundlagen der Elektrotechnik 1
Fundamentals of Electrical Engineering 1 Grundlagen der Elektrotechnik 1 Chapter: Operational Amplifiers / Operationsverstärker Michael E. Auer Source of figures: Alexander/Sadiku: Fundamentals of Electric
MehrModicon TSX Compact User Information / Benutzerinformation AS -BDEA -253
Modicon TSX Compact User Information / Benutzerinformation AS -BDEA -253 DOK-710 487.20-0198 Note For configuring the AS-- BDEA--253 the equipment master data file for PROFI- BUS--DP type 381 SWA 000 00
MehrBEDIENUNGSANLEITUNG EX MTX
BEDIENUNGSANLEITUNG EX MTX Diodenmatrix für die Anschaltung von bis zu 127 Klingeltasten an MD PBX oder MD PBX Key Diodes matrix for the connection of up to 127 bell buttons to MD PBX and MD PBX Key 1
MehrUSB Kabelkonfektion USB cabels assembly
USB Kabelkonfektion USB cabels assembly Customized cables Power cords Flat cables D-SUB cables Modular cables USB cables Video- and Audio cables 612 USB - Kabel von ASSMANN WSW components werden in den
MehrEASYSTART. 1. Nomenklatur. 2. Parametrier-Software installieren 1 / Nomenclature
EASYSTART linmot-easystart.doc Stand: 17.04.2018 Technische Änderungen vorbehalten! 1. Nomenklatur Positioniercontroller heißen bei der Firma NTI AG LinMot 'Drives'! JA² GmbH benutzt in Ihrer Angebotspalette
MehrSFP DSL Module Mounting Instructions. SG/XG 105(w)/115(w)/125(w)/135(w) Rev. 3
SFP DSL Module Mounting Instructions SFP DSL Module Mounting Instructions Please note This SFP DSL module allows you to directly connect your appliance to a VDSL2 line without using a separate modem It
MehrA VGA monitor of the highest resolution that you will be using on any computer in the installation A PS/2 Keyboard A PS/2 Mouse
PS/2 KVM SWITCH 2-PORT Vision 331217 Requirements Console A VGA monitor of the highest resolution that you will be using on any computer in the installation A PS/2 Keyboard A PS/2 Mouse Computers The following
MehrPS3 / PS4 / PC XBOX 360 GAMING HEADSET LX16
PS / PS / PC XBOX 60 GAMING HEADSET LX6 CHAT GAME Content Inhalt Lioncast LX6 gaming headset Lioncast LX6 Gaming Headset Inline remote kabelgebundene Fernbedienung MUTE - MIC - ON XBOX PS PS PC RCA splitter
MehrTW-75-IP40Trackball. Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40. Description
TW-75-IP40Trackball Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40 Description Applications: The advantages of this 75mm Trackball for back-panel-mounting are
MehrBedienungsanleitung Manual
Bedienungsanleitung Manual RX-EP-U UHF Empfänger (3) Multi-Schalter (2) Taste 2 Ohrbügel Das RX-EP-U ist ein PC-programmierbarer UHF-Empfänger mit 99 verfügbaren Speicherkanälen und 38 CTCSS- Kodierungen.
Mehr1. Komponenten des Bausatzes
1. Komponenten des Bausatzes Der Teilesatz 0510 590044 besteht aus folgenden Komponenten. 1 x Halter für Lasermarkierungen 3 x Lasermarkierungsleuchten mit Positionshalter 1 x Anschlußleiste für Lasermarkierungen
MehrPeakTech Zeitprogramm erstellen über Excel - Beispiel / Timed programs with Excel Example
PeakTech 6180 Zeitprogramm erstellen über Excel - Beispiel / Timed programs with Excel Example 1. Excel Datei erstellen / Create Excel file Öffnen Sie Excel und erstellen eine xls-datei unter einem beliebigen
MehrJV Installationsanleitung. Bediengerät. Artikel-Nr.: Version Lieferumfang
JV-1004 Bediengerät Jetter AG Kontakte: Gräterstraße 2 E-Mail - Vertrieb: sales@jetter.de D-71642 Ludwigsburg E-Mail - Hotline: hotline@jetter.de Germany Telefon - Hotline: +49(0)7141/2550-444 Installationsanleitung
MehrKurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen
Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen QuickStart Guide to read a transponder with a scemtec TT reader and software UniDemo Voraussetzung: - PC mit der
MehrBitte lesen Sie vor Inbetriebnahme des Gerätes die Bedienungsanleitung sorgfältig durch und bewahren Sie sie auf.
Fohhn-Net Remote Fohhn Control Network. Bedienungsanleitung User Manual FR-21 Media Control Interface Wichtiger Hinweis: Important information: Fohhn Audio Soft >Software Handling< (siehe separate Bedienungsanleitung
MehrITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.
D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.
MehrSBCO-RS232-NR SBCO-RS485-NR
SO-RS232-NR SO-RS485-NR Sunny oy ontrol / Sunny oy ontrol Plus Installation und Konfiguration der Schnittstellen Installation and onfiguration of the Interfaces Sunny oy ontrol / Sunny oy ontrol Plus 485P-SO-NR
MehrGAMING HEADSET LX16 PRO
GAMING HEADSET LX6 PRO CHAT GAME Content Inhalt Lioncast LX6 Pro gaming headset Lioncast LX6 Pro Gaming Headset Inline remote kabelgebundene Fernbedienung MUTE - MIC - ON XBOX PS PS PC RCA splitter cable
Mehrmiditech 4merge 4-fach MIDI Merger mit :
miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse
MehrTravelPilot 55/65 Active Connect. Bluetooth TELEFONMENÜ /TELEPHONE MENU
TravelPilot 55/65 Active Connect Bluetooth TELEFONMENÜ /TELEPHONE MENU Inhaltsverzeichnis / Table of content 3-10 DE 11-18 EN 2 Bluetooth Telefonmenü DE 3 Start Um Ihr Mobiltelefon zusammen mit Ihrem TravelPilot
MehrWestfalia Bedienungsanleitung. Nr
Bedienungsanleitung Nr. 107375 Bedienungsanleitung Satelliten Finder RL-TC-0101 Artikel Nr. 54 25 97 Instruction Manual Satellite Finder RL-TC-0101 Article No. 54 25 97 Benutzung Funktionsumfang Regelbare
MehrGamperl & Hatlapa GmbH Modem/WiFi settings
1. Log in - Anmelden Pic001 device front / Gerätevorderseite Pic002 Login screen / Anmeldebildschirm Connect your computer to one of the Ethernetports on the front (Pic001) of the modem. Start your browser
MehrA1XXX, B1XXX, C1XXX, E11XX, E12XX
EASYSTART linmot-easystart.doc Stand: 11.12.2015 Technische Änderungen vorbehalten! 1. Nomenklatur Positioniercontroller heißen bei der Firma NTI AG LinMot 'Drives'! JA² GmbH benutzt in Ihrer Angebotspalette
Mehrmobilcom-debitel SmartHome Schnell-Start-Anleitung Quick Start Guide
mobilcom-debitel SmartHome Schnell-Start-Anleitung Quick Start Guide 1. Cube anschließen 1. Connect Cube n Schließen Sie den Cube an die Stromversorgung an. n Legen Sie die Batterien polungsrichtig in
MehrKurzbedienungsanleitung Quick start guide
D Kurzbedienungsanleitung Quick start guide E IMPERIAL BAT 1 Bluetooth Audio Transmitter D Kurzbedienungsanleitung 1. Produktbeschreibung Der IMPERIAL BAD 1 ist ein Bluetooth-Transmitter zur drahtlosen
MehrAU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL
AU-D2 Coaxial/Optical Audio Converter OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Input Panel Diagram 2 3.2 Output Panel Diagram 2 3.3 Switcher
MehrAT module Specifications
AT module Specifications The rear panel includes the following connectors: Folgende Anschlüsse befinden sich auf der Rückseite: LTC input and output LTC-Eingang und Ausgang RS485/422/232 interface, Time
Mehrp^db=`oj===pìééçêíáåñçêã~íáçå=
p^db=`oj===pìééçêíáåñçêã~íáçå= Error: "Could not connect to the SQL Server Instance" or "Failed to open a connection to the database." When you attempt to launch ACT! by Sage or ACT by Sage Premium for
Mehr