1 Guard-locking mechanism HST-TS2 Ident. No Personnel key Locking bolt actuator Field for inscription Functional diagram closed, the personnel key is trapped open, the key is trapped (Key not supplied) Type label Technical Data Intended use The HST-TS2 door interlock comprises 2 locks and a lateral locking bolt. It is a guard-locking device and can be used on guards allowing full-body access and having blind spot areas. The shown personnel key can only be removed, if before a correspondingly coded primary key has been inserted and trapped in the primary lock. The operator then removes the personnel key and takes it with him into the hazardous area. By removing the personnel key, the primary key inserted before is trapped in the guardlocking device HST-TS2. It cannot be removed. Locking the door is done in reverse fashion with the locking bolt being inserted by pushing the safety door closed and inserting and turning the personnel key, and the primary key comes free. If used to protect access to a hazard, measures are required that secure that prior to access the hazardous movements are stopped, for instance by HST-S or HST-M devices. In conjunction with other components, the guard locking device HST-TS is used for locking guards in precipitators, quarry machines, or power plants etc. Environment: Ambient atmosphere: indoors/outdoors industrial Ambient temperature: C Mounting lock portion: Mounting actuator: Orientation actuator: Dimensions 31 12,5 M , , ,5 M ,5 stainless steel 4 M8 stainless steel bolts, 2 M6 stainless steel bolts, (fasteners not supplied) left M ,5 All dimensions in mm General tolerances to DIN 268-m 100,5 max , Rev EN 2012 Subject to alterations

2 Guard-locking mechanism HST-TS2 Ident. No Field for inscription Personnel key Functional diagram Locking bolt actuator closed, the personnel key is trapped open, the key is trapped (Key not supplied) Type label Technical Data Intended use The HST-TS2 door interlock comprises 2 locks and a lateral locking bolt. It is a guard-locking device and can be used on guards allowing full-body access and having blind spot areas. The shown personnel key can only be removed, if before a correspondingly coded primary key has been inserted and trapped in the primary lock. The operator then removes the personnel key and takes it with him into the hazardous area. By removing the personnel key, the primary key inserted before is trapped in the guardlocking device HST-TS2. It cannot be removed. Locking the door is done in reverse fashion with the locking bolt being inserted by pushing the safety door closed and inserting and turning the personnel key, and the primary key comes free. If used to protect access to a hazard, measures are required that secure that prior to access the hazardous movements are stopped, for instance by HST-S or HST-M devices. In conjunction with other components, the guard locking device HST-TS is used for locking guards in precipitators, quarry machines, or power plants etc. Environment: Ambient atmosphere: indoors/outdoors industrial Ambient temperature: C Mounting lock portion: Mounting actuator: Orientation actuator: Dimensions , ,5 M8 20 M M , ,5 9,5 stainless steel 4 M8 stainless steel bolts, 2 M6 stainless steel bolts, (fasteners not supplied) right All dimensions in mm General tolerances to DIN 268-m , ,5 6 max , Rev EN 2012 Subject to alterations

3 Guard-locking mechanism HST-TS2 Ident. No. 102 Personnel key Locking bolt actuator Field for inscription Type label Functional diagram closed, the personnel key is trapped open, the key is trapped (Key not supplied) Intended use The HST-TS2 door interlock comprises 2 locks and a lateral locking bolt. It is a guard-locking device and can be used on guards allowing full-body access and having blind spot areas. The shown personnel key can only be removed, if before a correspondingly coded primary key has been inserted and trapped in the primary lock. The operator then removes the personnel key and takes it with him into the hazardous area. By removing the personnel key, the primary key inserted before is trapped in the guardlocking device HST-TS2. It cannot be removed. Locking the door is done in reverse fashion with the locking bolt being inserted by pushing the safety door closed and inserting and turning the personnel key, and the primary key comes free. If used to protect access to a hazard, measures are required that secure that prior to access the hazardous movements are stopped, for instance by HST-S or HST-M devices. In conjunction with other components, the guard locking device HST-TS is used for locking guards in precipitators, quarry machines, or power plants etc. Technical Data Environment: Ambient atmosphere: indoors/outdoors industrial Ambient temperature: C Mounting lock portion: Mounting actuator: Orientation actuator: Dimensions 31 12,5 6, , M ,5 M ,5 stainless steel 4 M8 stainless steel bolts, from front, 1 M10 stainless steel bolt, (fasteners not supplied) left All dimensions in mm General tolerances to DIN 268-m ø Rev EN 2012 Subject to alterations

4 Guard-locking mechanism HST-TS2 Ident. No Field for inscription Personnel key Functional diagram Locking bolt actuator closed, the personnel key is trapped open, the key is trapped (Key not supplied) Type label Intended use The HST-TS2 door interlock comprises 2 locks and a lateral locking bolt. It is a guard-locking device and can be used on guards allowing full-body access and having blind spot areas. The shown personnel key can only be removed, if before a correspondingly coded primary key has been inserted and trapped in the primary lock. The operator then removes the personnel key and takes it with him into the hazardous area. By removing the personnel key, the primary key inserted before is trapped in the guardlocking device HST-TS2. It cannot be removed. Locking the door is done in reverse fashion with the locking bolt being inserted by pushing the safety door closed and inserting and turning the personnel key, and the primary key comes free. If used to protect access to a hazard, measures are required that secure that prior to access the hazardous movements are stopped, for instance by HST-S or HST-M devices. In conjunction with other components, the guard locking device HST-TS is used for locking guards in precipitators, quarry machines, or power plants etc. Technical Data Environment: Ambient atmosphere: indoors/outdoors industrial Ambient temperature: C Mounting lock portion: Mounting actuator: Orientation actuator: Dimensions ,5 8 M M , ,5 stainless steel 4 M8 stainless steel bolts, from front, 1 M10 stainless steel bolt, (fasteners not supplied) right All dimensions in mm General tolerances to DIN 268-m 6, , ø Rev EN 2012 Subject to alterations

5 Zuhaltungseinrichtung HST-TS2 Ident.-Nr Persönlicher Schlüssel Riegelbolzen- Betätiger Feld für Beschriftung Typenschild Funktionsschema Technische Daten Zuhaltungsvorrichtung geschlossen, persönlicher Zuhaltungsvorrichtung geöffnet, (Schlüssel nicht im Lieferumfang enthalten) Bestimmungsgemäße Verwendung Die Verriegelung HST-TS2 ist eine Zuhaltungseinrichtung mit seitlichem Riegelbolzen-Betätiger. Sie dient als Zuhaltungseinrichtung und kann an Schwenk- oder Schiebetüren von hintertretbaren, trennenden Schutzeinrichtungen mit nicht einsehbaren Bereichen eingesetzt werden. Der dargestellte persönliche Schlüssel kann erst entnommen werden, wenn zuvor ein entsprechend codierter Schlüssel in das davor liegende Schloss eingeführt und gedreht wurde. Der persönliche Schlüssel ist zu entnehmen und muss mit in den Gefahrenbereich genommen werden. Durch die Entnahme des persönlichen Schlüssels wird gewährleistet, dass der zuvor eingeführte Schlüssel der Zuhaltungseinrichtung HST-TS2 gefangen ist. Er kann nicht entnommen werden. Durch das Einführen des Betätigers in die Zuhaltungseinrichtung, verbunden mit dem Einführen und Drehen des persönlichen Schlüssels kann der zuvor eingeführte Schlüssel wieder entnommen werden. Soll mit der Zuhaltungseinrichtung der Zugang zu einem Gefahrenbereich gesichert werden, sind Maßnahmen erforderlich, die sicherstellen, dass Gefahr bringende Bewegungen stillgesetzt oder Energien frei geschaltet sind, zum Beispiel durch die Verwendung einer HST-S oder HST-M. Im Zusammenwirken mit anderen Komponenten wird die Zuhaltungseinrichtung HST-TS2 zum Verriegeln von Türen an trennenden, hintertretbareren Schutzeinrichtungen an Elektrofilteranlagen, Ziegeleien oder Kraftwerken usw. verwendet. Anwendungsumgebung: Umgebungsatmosphäre: innen/außen Industrieumgebung Umgebungstemperatur: C nichtrostender Stahl Befestigung Schlosskörper: von vorn, 4 M6 Edelstahlschrauben, Befestigung Betätiger: Betätigeranordnung: Abmessungen 46 1,5 39 9, ,5 von vorn, 2 M6 Edelstahlschrauben, (Befestigungsmaterial nicht im Lieferumfang enthalten) links Alle Maßangaben in mm Allgemeintoleranzen nach DIN 268-m ,5 max , Rev DE 2012 Änderungen vorbehalten

6 Zuhaltungseinrichtung HST-TS2 Ident.-Nr Feld für Beschriftung Persönlicher Schlüssel Funktionsschema Riegelbolzen- Betätiger Zuhaltungsvorrichtung geschlossen, persönlicher 5 Zuhaltungsvorrichtung geöffnet, Typenschild (Schlüssel nicht im Lieferumfang enthalten) Bestimmungsgemäße Verwendung Die Verriegelung HST-TS2 ist eine Zuhaltungseinrichtung mit seitlichem Riegelbolzen-Betätiger. Sie dient als Zuhaltungseinrichtung und kann an Schwenk- oder Schiebetüren von hintertretbaren, trennenden Schutzeinrichtungen mit nicht einsehbaren Bereichen eingesetzt werden. Der dargestellte persönliche Schlüssel kann erst entnommen werden, wenn zuvor ein entsprechend codierter Schlüssel in das davor liegende Schloss eingeführt und gedreht wurde. Der persönliche Schlüssel ist zu entnehmen und muss mit in den Gefahrenbereich genommen werden. Durch die Entnahme des persönlichen Schlüssels wird gewährleistet, dass der zuvor eingeführte Schlüssel der Zuhaltungseinrichtung HST-TS2 gefangen ist. Er kann nicht entnommen werden. Durch das Einführen des Betätigers in die Zuhaltungseinrichtung, verbunden mit dem Einführen und Drehen des persönlichen Schlüssels kann der zuvor eingeführte Schlüssel wieder entnommen werden. Soll mit der Zuhaltungseinrichtung der Zugang zu einem Gefahrenbereich gesichert werden, sind Maßnahmen erforderlich, die sicherstellen, dass Gefahr bringende Bewegungen stillgesetzt oder Energien frei geschaltet sind, zum Beispiel durch die Verwendung einer HST-S oder HST-M. Im Zusammenwirken mit anderen Komponenten wird die Zuhaltungseinrichtung HST-TS2 zum Verriegeln von Türen an trennenden, hintertretbareren Schutzeinrichtungen an Elektrofilteranlagen, Ziegeleien oder Kraftwerken usw. verwendet. Technische Daten Anwendungsumgebung: Umgebungsatmosphäre: innen/außen Industrieumgebung Umgebungstemperatur: C nichtrostender Stahl Befestigung Schlosskörper: von vorn, 4 M6 Edelstahlschrauben, Befestigung Betätiger: Betätigeranordnung: Abmessungen ,5 von vorn, 2 M6 Edelstahlschrauben, (Befestigungsmaterial nicht im Lieferumfang enthalten) rechts Alle Maßangaben in mm Allgemeintoleranzen nach DIN 268-m 9, , ,5 6 max , Rev DE 2012 Änderungen vorbehalten

7 Zuhaltungseinrichtung HST-TS2 Ident.-Nr Persönlicher Schlüssel Riegelbolzen- Betätiger Feld für Beschriftung Typenschild Funktionsschema Zuhaltungsvorrichtung geschlossen, persönlicher Zuhaltungsvorrichtung geöffnet, (Schlüssel nicht im Lieferumfang enthalten) Bestimmungsgemäße Verwendung Die Verriegelung HST-TS2 ist eine Zuhaltungseinrichtung mit seitlichem Riegelbolzen-Betätiger. Sie dient als Zuhaltungseinrichtung und kann an Schwenk- oder Schiebetüren von hintertretbaren, trennenden Schutzeinrichtungen mit nicht einsehbaren Bereichen eingesetzt werden. Der dargestellte persönliche Schlüssel kann erst entnommen werden, wenn zuvor ein entsprechend codierter Schlüssel in das davor liegende Schloss eingeführt und gedreht wurde. Der persönliche Schlüssel ist zu entnehmen und muss mit in den Gefahrenbereich genommen werden. Durch die Entnahme des persönlichen Schlüssels wird gewährleistet, dass der zuvor eingeführte Schlüssel der Zuhaltungseinrichtung HST-TS2 gefangen ist. Er kann nicht entnommen werden. Durch das Einführen des Betätigers in die Zuhaltungseinrichtung, verbunden mit dem Einführen und Drehen des persönlichen Schlüssels kann der zuvor eingeführte Schlüssel wieder entnommen werden. Soll mit der Zuhaltungseinrichtung der Zugang zu einem Gefahrenbereich gesichert werden, sind Maßnahmen erforderlich, die sicherstellen, dass Gefahr bringende Bewegungen stillgesetzt oder Energien frei geschaltet sind, zum Beispiel durch die Verwendung einer HST-S oder HST-M. Im Zusammenwirken mit anderen Komponenten wird die Zuhaltungseinrichtung HST-TS2 zum Verriegeln von Türen an trennenden, hintertretbareren Schutzeinrichtungen an Elektrofilteranlagen, Ziegeleien oder Kraftwerken usw. verwendet. Technische Daten Anwendungsumgebung: Umgebungsatmosphäre: innen/außen Industrieumgebung Umgebungstemperatur: C nichtrostender Stahl Befestigung Schlosskörper: von vorn, 4 M6 Edelstahlschrauben, Befestigung Betätiger: Betätigeranordnung: Abmessungen 46 1, von vorn, 1 M10 Edelstahlschraube, (Befestigungsmaterial nicht im Lieferumfang enthalten) links Alle Maßangaben in mm Allgemeintoleranzen nach DIN 268-m ø Rev DE 2012 Änderungen vorbehalten

8 Zuhaltungseinrichtung HST-TS2 Ident.-Nr Feld für Beschriftung Persönlicher Schlüssel Funktionsschema Riegelbolzen- Betätiger 5 Zuhaltungsvorrichtung geschlossen, persönlicher Zuhaltungsvorrichtung geöffnet, Typenschild (Schlüssel nicht im Lieferumfang enthalten) Bestimmungsgemäße Verwendung Die Verriegelung HST-TS2 ist eine Zuhaltungseinrichtung mit seitlichem Riegelbolzen-Betätiger. Sie dient als Zuhaltungseinrichtung und kann an Schwenk- oder Schiebetüren von hintertretbaren, trennenden Schutzeinrichtungen mit nicht einsehbaren Bereichen eingesetzt werden. Der dargestellte persönliche Schlüssel kann erst entnommen werden, wenn zuvor ein entsprechend codierter Schlüssel in das davor liegende Schloss eingeführt und gedreht wurde. Der persönliche Schlüssel ist zu entnehmen und muss mit in den Gefahrenbereich genommen werden. Durch die Entnahme des persönlichen Schlüssels wird gewährleistet, dass der zuvor eingeführte Schlüssel der Zuhaltungseinrichtung HST-TS2 gefangen ist. Er kann nicht entnommen werden. Durch das Einführen des Betätigers in die Zuhaltungseinrichtung, verbunden mit dem Einführen und Drehen des persönlichen Schlüssels kann der zuvor eingeführte Schlüssel wieder entnommen werden. Soll mit der Zuhaltungseinrichtung der Zugang zu einem Gefahrenbereich gesichert werden, sind Maßnahmen erforderlich, die sicherstellen, dass Gefahr bringende Bewegungen stillgesetzt oder Energien frei geschaltet sind, zum Beispiel durch die Verwendung einer HST-S oder HST-M. Im Zusammenwirken mit anderen Komponenten wird die Zuhaltungseinrichtung HST-TS2 zum Verriegeln von Türen an trennenden, hintertretbareren Schutzeinrichtungen an Elektrofilteranlagen, Ziegeleien oder Kraftwerken usw. verwendet. Technische Daten Anwendungsumgebung: Umgebungsatmosphäre: innen/außen Industrieumgebung Umgebungstemperatur: C nichtrostender Stahl Befestigung Schlosskörper: von vorn, 4 M6 Edelstahlschrauben, Befestigung Betätiger: Betätigeranordnung: Abmessungen ,5 von vorn, 1 M10 Edelstahlschraube, (Befestigungsmaterial nicht im Lieferumfang enthalten) rechts Alle Maßangaben in mm Allgemeintoleranzen nach DIN 268-m 39 1, ø Rev DE 2012 Änderungen vorbehalten

Hazards and measures against hazards by implementation of safe pneumatic circuits

Hazards and measures against hazards by implementation of safe pneumatic circuits Application of EN ISO 13849-1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free

Mehr

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT Montageanweisung Mounting Instructions Der Umschalter dient zum unterbrechungsfreien Umschalten von Installations-drähten

Mehr

Westfalia Bedienungsanleitung. Nr

Westfalia Bedienungsanleitung. Nr Westfalia Bedienungsanleitung Nr. 108610 Bedienungsanleitung Edelstahl Sicherheits-Brennbehälter Artikel Nr. 10 99 83 Sicherheitshinweise Der Sicherheits-Brennbehälter ist zur Verwendung in dem Westfalia

Mehr

Werkzeugwagen VAS Tool trolley VAS

Werkzeugwagen VAS Tool trolley VAS Flexibel einsetzbar Bedarfsgerecht zu konfigurieren Hochwertige Qualität Can be used flexibly Can be configured according to requirements High level of quality Werkzeugwagen VAS 276 001 Tool trolley VAS

Mehr

C R 2025 C LOSE PUSH OPEN

C R 2025 C LOSE PUSH OPEN 3V C R 2025 C LOSE PUSH OPEN ) ) ) 25 222 3V C R 2025 C LOSE PUSH OPEN 25 222 3V C R 2025 C LOSE PUSH OPEN 25 222 Den här symbolen på produkten eller i instruktionerna betyder att den elektriska

Mehr

Mortise lock for internal doors. Einsteckschloss für Zimmertüren. Art. Nr./Art. No. 910 Dornmaß/Backset mm 55 Kastenbreite/Width mm 85

Mortise lock for internal doors. Einsteckschloss für Zimmertüren. Art. Nr./Art. No. 910 Dornmaß/Backset mm 55 Kastenbreite/Width mm 85 Einsteckschloss für Zimmertüren Mortise lock for internal doors 910 Art. Nr./Art. No. 910 Dornmaß/Backset mm 55 Kastenbreite/Width mm 85 Einsteck-Zimmertürschloss, Buntbart-Ausführung, 8mm Nuss, ohne Wechsel,

Mehr

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H 12070 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Material: - Aluminium and steel Applications:

Mehr

114-18867 09.Jan 2014 Rev C

114-18867 09.Jan 2014 Rev C Application Specification 114-18867 09.Jan 2014 Rev C High Speed Data, Pin Headers 90 / 180 4pos., shie lded High Speed Data, Stiftleiste 90 / 180, geschirmt Description Beschreibung 1. Packaging of pin

Mehr

Rohrschieber mit Schließfeder Slide Valve spring loaded

Rohrschieber mit Schließfeder Slide Valve spring loaded Rohrschieber mit Schließfeder Slide Valve spring loaded Rohrschieber als automatisches Entlüftungsventil Slide Valve as automatic air relief valve Type: RSF DN: 50 300 (2 12 ) PN: 16 160 (Class 150 900)

Mehr

rear view server cabinet perforated steel door, divided

rear view server cabinet perforated steel door, divided 19 Server Cabinet Standard Page 1 of 5 Art.-No. 693126.60P1P2.. 693147.82P2 depth rail + traverse for high max. load front view server cabinet perforated steel door, one-part rear view server cabinet perforated

Mehr

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H Rotary Dampers with high-torque range WRD-H 67 WRD-H 85 WRD-H 128 WRD-H 161 WRD-H 21 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Applications: - Mechanical and

Mehr

Attenuator and Distribution System Zehnder ComfoWell 520

Attenuator and Distribution System Zehnder ComfoWell 520 Attenuator and Distribution System Zehnder ComfoWell 520 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy

Mehr

1. General information... 2 2. Login... 2 3. Home... 3 4. Current applications... 3

1. General information... 2 2. Login... 2 3. Home... 3 4. Current applications... 3 User Manual for Marketing Authorisation and Lifecycle Management of Medicines Inhalt: User Manual for Marketing Authorisation and Lifecycle Management of Medicines... 1 1. General information... 2 2. Login...

Mehr

Solder area 80µ Sn/50µ Ni

Solder area 80µ Sn/50µ Ni # page 30 Part No. Description Y-ConJack-11 8(8) Y-ConJack-21 8(8)+2 improved shielding, with or without 2 power contacts with PCB-locks. Y-ConJack-21-PP 8(8)+2 improved shielding, 2 power contacts and

Mehr

Installation manual / Montageanleitung WBC2 splice patch with Fibertray Spleissung/Rangierung mit Fibertray

Installation manual / Montageanleitung WBC2 splice patch with Fibertray Spleissung/Rangierung mit Fibertray Content of Assembly Instruction I. Required tools II. Required parts III. Installation Inhalt der Montageanleitung I. Benötigte Werkzeuge II. Benötigte Teile III. Installation I. Required tools: I. Benötigtes

Mehr

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient Filing system designer FileDirector Version 2.5 Novelties FileDirector offers an easy way to design the filing system in WinClient. The filing system provides an Explorer-like structure in WinClient. The

Mehr

Technical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00)

Technical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00) Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00) Inhalt S./P. 1. Beschreibung /

Mehr

E1 M1 P5 TK2 K2 20,6. hohe elektrische Nennleistung Schlüsselabzugstellung (Option) Wahl Aus/Ein. Umschalter/Wechsler. mit Federumkehr oder Umschalter

E1 M1 P5 TK2 K2 20,6. hohe elektrische Nennleistung Schlüsselabzugstellung (Option) Wahl Aus/Ein. Umschalter/Wechsler. mit Federumkehr oder Umschalter Frontplattenmontage Schlüsselschalter Baureihe E1 M1 P5 TK2 K2 Lochausschnitt (mm) 15,1 15,1 15,1 15,1 20,6 16,2/22,5 19,1 Charakteristik zweipoliger Umschalter/ Wechsler oder drei Schaltkreisschaltfunktionen

Mehr

USB -> Seriell Adapterkabel Benutzerhandbuch

USB -> Seriell Adapterkabel Benutzerhandbuch USB -> Seriell Adapterkabel Benutzerhandbuch 1. Produkt Eigenschaften 1 2. System Vorraussetzungen 1 3. Treiber Installation (Alle Windows Systeme) 1 4. Den COM Port ändern 2 5. Einstellen eines RS232

Mehr

Montageanleitung DORMA Schloss mit Drückerführung Studio Rondo Studio Classic ARCOS Studio

Montageanleitung DORMA Schloss mit Drückerführung Studio Rondo Studio Classic ARCOS Studio Montageanleitung DORMA Schloss mit Drückerführung Studio Rondo Studio Classic ARCOS Studio Installation instructions DORMA lock with follower Studio Rondo Studio Classic ARCOS Studio DORMA-Glas Stand/Issue

Mehr

Uhrenbeweger

Uhrenbeweger Uhrenbeweger 10006661 Sehr geehrter Kunde, zunächst möchten wir Ihnen zum Erwerb Ihres Gerätes gratulieren. Bitte lesen Sie die folgenden Anschluss- und Anwendungshinweise sorgfältig durch und befolgen

Mehr

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät Betriebsanleitung RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät ä 2 Operating Instructions RS232 Connection, RXU10 Setting up an RS232 connection

Mehr

X83-Konverter Instructions

X83-Konverter Instructions 1. General The X83-Konverter converts GAEB call-for-tender data *) directly into MS Excel format. Exchange phases D81, D83, P81, P83, X81 and X83 are supported. Processing of the tender takes place completely

Mehr

Statischer Sonnenschutz Fixed sunblinds

Statischer Sonnenschutz Fixed sunblinds E-Klasse / E-Class Statischer Sonnenschutz Statischer Sonnenschutz - Der statische Sonnenschutz ist gegenüber dem Rollo über Halter am Fahrzeug fest fixiert. - Bei Nichtgebrauch kann der gesamte Sonnenschutz

Mehr

Parameter-Updatesoftware PF-12 Plus

Parameter-Updatesoftware PF-12 Plus Parameter-Updatesoftware PF-12 Plus Mai / May 2015 Inhalt 1. Durchführung des Parameter-Updates... 2 2. Kontakt... 6 Content 1. Performance of the parameter-update... 4 2. Contact... 6 1. Durchführung

Mehr

Produktinformation Access-Gateway. Product information Access gateway AGW 670-0

Produktinformation Access-Gateway. Product information Access gateway AGW 670-0 Produktinformation Access-Gateway Product information Access gateway AGW 670-0 1 2 3 4 2 Deutsch Anwendung Access-Gateway zur physikalischen Trennung von 2 Netzwerken an einem Access-Server. Durch den

Mehr

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren Hochpotenzial - Hochspannungs - Trenntransformatoren pri - sec und einer Leistung von 1 VA bis 3000 VA Isoliertrafo, Isolationstransformator Einsatzmöglichkeiten Hochspannungstrenntransformatoren werden

Mehr

CABLE TESTER. Manual DN-14003

CABLE TESTER. Manual DN-14003 CABLE TESTER Manual DN-14003 Note: Please read and learn safety instructions before use or maintain the equipment This cable tester can t test any electrified product. 9V reduplicated battery is used in

Mehr

STILLLEGUNG CANCELLATION KIT

STILLLEGUNG CANCELLATION KIT STILLLEGUNG CANCELLATION KIT EINBAUHINWEISE Elektronik Satz INSTALLATION INSTRUCTIONS Cancellation kit Seite / Page 1 Vorderachse und Hinterachse/ Front axle and Rear axle: 1. Steckersicherung öffnen.

Mehr

Directions. Trouble shooting

Directions. Trouble shooting Betriebsanleitung 1. Legen Sie die Uhr mit der Vorderwand auf den Tisch und öffnen Sie die Rückwand des Uhrengehäuses (A). 2. Entfernen Sie das Papier welches zwischen die Rückwand und Tonfeder geklemmt

Mehr

Ex solenoid interlocks // Ex AZM 415

Ex solenoid interlocks // Ex AZM 415 Features/Options Ex zone 1 and 21 Special version up to +90 C ambient temperature for dust Ex zone 21 available (HU) Two Ex switch inserts in one enclosure Spring-to-lock or power-to-lock principle Problem-free

Mehr

p^db=`oj===pìééçêíáåñçêã~íáçå=

p^db=`oj===pìééçêíáåñçêã~íáçå= p^db=`oj===pìééçêíáåñçêã~íáçå= Error: "Could not connect to the SQL Server Instance" or "Failed to open a connection to the database." When you attempt to launch ACT! by Sage or ACT by Sage Premium for

Mehr

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012 Heaters for Enclosures SM 10-45 - Selbstregelnde PTC-Heizungen mit 10-45 W - Optimiertes Profil mit verbesserter Heizleistung und geringerer Oberflächentemperatur - Montage und Anschluss ohne Werkzeug

Mehr

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016 Overview The Hamburg Süd VGM-Portal is an application which enables to submit VGM information directly to Hamburg Süd via our e-portal web page. You can choose to insert VGM information directly, or download

Mehr

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H. ZU 0859 Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H www.knick.de Bauart und Funktion Der Endlagenschalter ZU 0859 wandelt die pneumatischen Endlagen signale,

Mehr

Montageanleitung DORMA PT 10 Unterer Eckbeschlag DORMA PT 20 Oberer Eckbeschlag

Montageanleitung DORMA PT 10 Unterer Eckbeschlag DORMA PT 20 Oberer Eckbeschlag Montageanleitung DORMA PT 10 Unterer Eckbeschlag DORMA PT 20 Oberer Eckbeschlag Installation instruction DORMA PT 10 Bottom patch fitting DORMA PT 20 Top patch fitting / 003620 800.2.368.6.32 Wichtige

Mehr

Cameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe

Cameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe Cameraserver mini commissioning Page 1 Cameraserver - commissioning Contents 1. Plug IN... 3 2. Turn ON... 3 3. Network configuration... 4 4. Client-Installation... 6 4.1 Desktop Client... 6 4.2 Silverlight

Mehr

GSP EXPERT GSP EXPERT Folgende Verbesserungen wurden an der GSP in der Ausführung EXPERT durchgeführt: Runder Lauf (erhöht die Präzision) Schwingungsdämpfende Laufummantelung aus Kunststoff (nur GSP.22l.r.)

Mehr

Cleanroom Fog Generators Volcano VP 12 + VP 18

Cleanroom Fog Generators Volcano VP 12 + VP 18 Cleanroom Fog Generators Volcano VP 12 + VP 18 Description & Functional Principle (Piezo Technology) Cleanrooms are dynamic systems. People and goods are constantly in motion. Further installations, production

Mehr

DIE NEUORGANISATION IM BEREICH DES SGB II AUSWIRKUNGEN AUF DIE ZUSAMMENARBEIT VON BUND LNDERN UND KOMMUNEN

DIE NEUORGANISATION IM BEREICH DES SGB II AUSWIRKUNGEN AUF DIE ZUSAMMENARBEIT VON BUND LNDERN UND KOMMUNEN DIE NEUORGANISATION IM BEREICH DES SGB II AUSWIRKUNGEN AUF DIE ZUSAMMENARBEIT VON BUND LNDERN UND KOMMUNEN WWOM537-PDFDNIBDSIAADZVBLUK 106 Page File Size 4,077 KB 16 Feb, 2002 COPYRIGHT 2002, ALL RIGHT

Mehr

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens How-To-Do Hardware Configuration of the CC03 via SIMATIC Manager from Siemens Content Hardware Configuration of the CC03 via SIMATIC Manager from Siemens... 1 1 General... 2 1.1 Information... 2 1.2 Reference...

Mehr

s b astec edelstahl design beschlaege

s b astec edelstahl design beschlaege s b c h l a g 5 0 0 R astec e edelstahl design beschlaege flexibler drehtuerbeschlag flexible pivoting door fitting im design zum typ 600 passend wurde der drehtuerbeschlag 500 entwickelt. die optik besticht

Mehr

Exercise (Part II) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1

Exercise (Part II) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1 Exercise (Part II) Notes: The exercise is based on Microsoft Dynamics CRM Online. For all screenshots: Copyright Microsoft Corporation. The sign ## is you personal number to be used in all exercises. All

Mehr

Prüfbericht Nr. / Test Report No: F (Edition 1)

Prüfbericht Nr. / Test Report No: F (Edition 1) Emission date: 22.01.2015 Page: 1 of 5 Prüfbericht Nr. / Test Report No: F4-44254-48401-01 (Edition 1) Auftraggeber Applicant Geräteart Type of equipment Typenbezeichnung Type designation Seriennummer

Mehr

Sicherheit / Sicherung - unterschiedliche Begriffsbestimmung, gemeinsame Fachaspekte

Sicherheit / Sicherung - unterschiedliche Begriffsbestimmung, gemeinsame Fachaspekte Sicherheit / Sicherung - unterschiedliche Begriffsbestimmung, gemeinsame Fachaspekte F. Seidel, BfS Salzgitter (Juli 2002) 1) Begriffsbestimmung (Vergleich unter Nutzung nationaler und internationaler

Mehr

FR777 Differenzial-Kulissenauszug Bodenmontage, 200 kg Tragkraft, mit Gegenführung

FR777 Differenzial-Kulissenauszug Bodenmontage, 200 kg Tragkraft, mit Gegenführung http://www.fulterer.com http://www.fultererusa.com Instructions F777 Differenzial-Kulissenauszug Bodenmontage, 00 kg Tragkraft, mit Gegenführung F777 Progressive-Action Pantry Pull-out, Bottom Mount 450

Mehr

Hör auf zu ziehen! Erziehungsleine Training Leash

Hör auf zu ziehen! Erziehungsleine Training Leash Hör auf zu ziehen! Erziehungsleine Training Leash 1 2 3 4 5 6 7 Erziehungsleine Hör auf zu ziehen Ihr Hund zieht an der Leine, und Sie können ihm dieses Verhalten einfach nicht abgewöhnen? Die Erziehungsleine

Mehr

a new line of steam sterilizers

a new line of steam sterilizers a new line of steam sterilizers ticheeasy to use and high consumption savings multifunction display controlled by micro-processor double and patented motor-operated closure stainless steel chamber without

Mehr

Bedienungsanleitung User Manual. System AED Plus

Bedienungsanleitung User Manual. System AED Plus Bedienungsanleitung User Manual System AED Plus INHALTSVERZEICHNIS TABLE OF CONTENTS Einleitung Sicherheitshinweise Verwendungszweck... 3 Lieferumfang Technische Daten Zubehör.... 4 Montage. 5 Bedienung

Mehr

Elektroniktresor Serie Tiger. Bedienungsanleitung für Elektronikschloss EG. Inhalt

Elektroniktresor Serie Tiger. Bedienungsanleitung für Elektronikschloss EG. Inhalt Elektroniktresor Serie Tiger Bedienungsanleitung für Elektronikschloss EG Inhalt 1. Funktionsübersicht 2. Wichtige Hinweise zur Bedienung / Haftungsausschluss 3. Inbetriebnahme 4. Umstellen der Öffnungscodes

Mehr

Produktinformation Access Upgrade Video. Product information Access licence for video upgrade AUV 870-0 T AUV 870-0 F

Produktinformation Access Upgrade Video. Product information Access licence for video upgrade AUV 870-0 T AUV 870-0 F Produktinformation Access Upgrade Video Product information Access licence for video upgrade AUV 870-0 T AUV 870-0 F 1+2 100-1216 V1.1.2 1216-11-1159 MAC-Adresse D4-E3-2C-XX-XX-XX 3+4 press click 2 5 6

Mehr

DATENBLATT / FACT SHEET

DATENBLATT / FACT SHEET DATENBLATT / FACT SHEET ART.-NR: SQUEEZE 3 PENDELLEUCHTE / SUSPENDED LUMINAIRE LED.next höheneinstellbare Pendelleuchte für den Home- und Loungebereich. Einzeln oder aber auch in Gruppen anwendbar. Lichtaustritt

Mehr

Daimler. Patent Portfolio PRE-SAFE.

Daimler. Patent Portfolio PRE-SAFE. Daimler. Patent Portfolio PRE-SAFE. Licensing Patent Portfolio PRE-SAFE Patent Portfolio PRE-SAFE Potentially hazardous driving situations such as skidding, emergency brakings or sudden obstacle avoidance

Mehr

Gas Flow Sensor. Der nächste Schritt zu mehr Prozesssicherheit The next step to a more reliable process

Gas Flow Sensor. Der nächste Schritt zu mehr Prozesssicherheit The next step to a more reliable process Gas Flow Sensor Der nächste Schritt zu mehr Prozesssicherheit The next step to a more reliable process Document no.: PIN0110ML Revision: sks0112.ml.2.a.bp Gas Flow Sensor Der industriell bewährte Drahtvorschub

Mehr

Anleitung / User Manual

Anleitung / User Manual 3,5 USB HDD Enclosure Anleitung / User Manual Die Sicherung von Daten innerhalb der Festplatte ist nicht durch den Hersteller garantiert. Wir sind nicht verantwortlich für Datenverlust, fertigen Sie regelmäßig

Mehr

Wiegen / Balance 6.01. Inhaltsübersicht Contents Seite / Page

Wiegen / Balance 6.01. Inhaltsübersicht Contents Seite / Page 6 Wiegen / Balance Inhaltsübersicht Contents Seite / Page l 6.1 Taschenwaage l 6.2 Präzisionswaagen l 6.3 Plattformwaagen l 6.4 Analysewaagen l 6.5 Tischwaagen l 6.6 Bodenwaagen l 6.7 Feuchtebestimmer

Mehr

INSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示

INSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示 BEDIENUNGSANLEITUNG To comply with the published safety standards, the following must be observed when using this power supply. Um den zur Zeit gültigen Sicherheitsbestimmungen zu genügen, müssen die nachstehenden

Mehr

User Manual Bedienungsanleitung. www.snom.com. snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter. English. Deutsch

User Manual Bedienungsanleitung. www.snom.com. snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter. English. Deutsch English snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter Deutsch User Manual Bedienungsanleitung 2007 snom technology AG All rights reserved. Version 1.00 www.snom.com English snom Wireless

Mehr

p^db=`oj===pìééçêíáåñçêã~íáçå=

p^db=`oj===pìééçêíáåñçêã~íáçå= p^db=`oj===pìééçêíáåñçêã~íáçå= How to Disable User Account Control (UAC) in Windows Vista You are attempting to install or uninstall ACT! when Windows does not allow you access to needed files or folders.

Mehr

HPS.04.696.10000/B Revision: 01. Hauptständer KTM 990 SM-T / SM-R '09 Center Stand KTM 990 SM-T / SM-R '09

HPS.04.696.10000/B Revision: 01. Hauptständer KTM 990 SM-T / SM-R '09 Center Stand KTM 990 SM-T / SM-R '09 Hauptständer KTM 0 SM-T / SM-R '0 Center Stand KTM 0 SM-T / SM-R '0 Montagehinweise Revision: 01 Mounting Instruction Achtung: Die Kurven- und Bodenfreiheit kann durch einen Hauptständer eingeschränkt

Mehr

s b astec edelstahl design beschlaege

s b astec edelstahl design beschlaege s b c h l a g 5 0 0 R astec e edelstahl design beschlaege flexibler drehtuerbeschlag flexible pivoting door fitting beschlag 500 im design zum typ 600 passend wurde der drehtuerbeschlag 500 entwickelt.

Mehr

ReadMe zur Installation der BRICKware for Windows, Version 6.1.2. ReadMe on Installing BRICKware for Windows, Version 6.1.2

ReadMe zur Installation der BRICKware for Windows, Version 6.1.2. ReadMe on Installing BRICKware for Windows, Version 6.1.2 ReadMe zur Installation der BRICKware for Windows, Version 6.1.2 Seiten 2-4 ReadMe on Installing BRICKware for Windows, Version 6.1.2 Pages 5/6 BRICKware for Windows ReadMe 1 1 BRICKware for Windows, Version

Mehr

K...<Bestell-Nr. / code>

K...<Bestell-Nr. / code> K...< / code> TECHNISCHE DATEN TECHNICAL DATA Bauartgeprüft gemäß type-approved according IEC/DIN EN 61439-2 VDE 0660-600-2 Nenn-Isolationsspannung AC nominal insulation voltage AC 1000V /50Hz Nenn-Isolationsspannung

Mehr

Montageanleitung Racing Lenkerstummelsatz

Montageanleitung Racing Lenkerstummelsatz Montageanleitung Racing Lenkerstummelsatz Bei Verwendung der Racing Lenkerstummel muss erst ein Loch (Bild 2) zur Befestigung der Armaturen gebohrt werden. Durchmesser = 3,5 mm / Abstand vom Lenkerende

Mehr

Installation Instructions

Installation Instructions EN DE Installation Instructions WLAN Installation Kit, 300 Mbps, 5 GHz, 16 dbi AK-4 Wireless Kit Scope of delivery Junction box AK-4 (1x) 1 Connection board AK-4 CB with 12VDC power supply unit (1x) 2

Mehr

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten. Produktdatenblatt Artikel Nr.: 341107 Wandaufbauleuchte, Alpha II, Weiß, 220-240V AC/50-60Hz, 100,00 W Technische Daten Charakteristik Material Farbe Weiß Optik im Lieferumfang Elektrische Daten Leistung

Mehr

AUFBEWAHRUNG - PRAKTISCHE LÖSUNGEN FÜR GERÄTERÄUME STORAGE PRACTICAL SOLUTIONS FOR EQUIPMENT COMPARTMENTS

AUFBEWAHRUNG - PRAKTISCHE LÖSUNGEN FÜR GERÄTERÄUME STORAGE PRACTICAL SOLUTIONS FOR EQUIPMENT COMPARTMENTS Ausrüstungsgegenstände sollen im Geräteraum sicher und übersichtlich aufbewahrt sein jederzeit griffbereit wenn es darauf ankommt. Wir haben praktische und bewährte Lösungen für Ihre Geräteräume auf Lager.

Mehr

GTP - Permanent Elektro Haftmagnet Datenblätter. GTP - Permanent electro magnet Datasheets

GTP - Permanent Elektro Haftmagnet Datenblätter. GTP - Permanent electro magnet Datasheets GTP - Datenblätter GTP - Datasheets GTP GTP Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] F Haft F Holding [N] GTP-20 Ø20 x 22 70 GTP-30 Ø30 x 32 130 GTP-34 Ø34 x 39.6 260

Mehr

We are pleased to inform you that the addendum this requires to the existing product approval has now been successfully completed.

We are pleased to inform you that the addendum this requires to the existing product approval has now been successfully completed. MSA AUER GmbH! Thiemannstraße 1! D-12059 Berlin To our customers Name Phone, Fax E-mail Date Malte Kaas (030) 6886-0, -1613 Malte.Kaas@MSAsafety.com 10.12.2014 Duracell MN 1500 Procell Retail availability

Mehr

Titelbild1 ANSYS. Customer Portal LogIn

Titelbild1 ANSYS. Customer Portal LogIn Titelbild1 ANSYS Customer Portal LogIn 1 Neuanmeldung Neuanmeldung: Bitte Not yet a member anklicken Adressen-Check Adressdaten eintragen Customer No. ist hier bereits erforderlich HERE - Button Hier nochmal

Mehr

vario The new versatile roller blind concept

vario The new versatile roller blind concept vario The new versatile roller blind concept VARIO CASSETTE Vario a flexible roller blind system with a cassette for wall, ceiling and niche mounting. The system offers several different mechanism options

Mehr

drawbar eye series 2010

drawbar eye series 2010 drawbar eye series 2010 directive 94/20/EG / class S DIN 74054-40A / material St52-3 (no. 1.0570) / with bush 40 mm parameters for centre-axle trailer s ṣhaft cross section order no H x B mm length A mm

Mehr

Manual Positioning Systems

Manual Positioning Systems M anue l l e Po si tio n iers y s t e me Manual Positioning Systems Linearversteller LT...4-4 linear translation stages LT Kreuztische MT...4-5 XY translation stages MT Hubtische HT...4-6 vertical translation

Mehr

HEAG 151, 152, 153, 154 Digital Converter

HEAG 151, 152, 153, 154 Digital Converter Montage- und Betriebsanleitung Installation and operating instructions MB095-11055704 Baumer_HEAG151-152-153-154_II_DE-EN (16A1) HEAG 151, 152, 153, 154 Digital Converter 1-2 Allgemeine Hinweise - Funktionsweise

Mehr

Produktinformation _185PNdeen

Produktinformation _185PNdeen Produktinformation 201407_185PNdeen Solldaten-UPGRADE Juli 2014 WA 900 / 920 / 020 / 950 / 970 CURA S 800 / 860 / 060 / 900 / 960 WAB01 / WAB 02 CCT CURA R1200 / CURA R2000/ API R2000 BOSCH FWA 51x Auf

Mehr

Die Datenmanipulationssprache SQL

Die Datenmanipulationssprache SQL Die Datenmanipulationssprache SQL Daten eingeben Daten ändern Datenbank-Inhalte aus Dateien laden Seite 1 Data Manipulation Language A DML statement is executed when you Add new rows to a table Modify

Mehr

Außenknauf Innenkanuf Profilzylinder

Außenknauf Innenkanuf Profilzylinder DATENBLATT BCM Offline-Leser BCM Elektronischer Knaufzylinder FL IP55 Set AA/BB Anwendungsbereich Konformität Identifikation max. Anzahl Betätigungen mit einem Batteriesatz 35.000 Benutzerführung Batterien

Mehr

High Density D-Sub Crimp Connectors High Density D-Sub Crimp Steckverbinder

High Density D-Sub Crimp Connectors High Density D-Sub Crimp Steckverbinder High Density D-Sub Crimp Connectors High Density D-Sub Crimp Steckverbinder Technical Data Technische Daten Mechanical Data Mechanische Daten Shell Gehäuse Insulator Isolierkörper Signal contacts Signalkontakte

Mehr

Exercise (Part I) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1

Exercise (Part I) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1 Exercise (Part I) Notes: The exercise is based on Microsoft Dynamics CRM Online. For all screenshots: Copyright Microsoft Corporation. The sign ## is you personal number to be used in all exercises. All

Mehr

UNIGATE CL Konfiguration mit WINGATE

UNIGATE CL Konfiguration mit WINGATE UNIGATE CL Konfiguration mit WINGATE - UNIGATE CL Configuration via WINGATE Art.-Nr.: V3928 Deutschmann Automation GmbH & Co. KG Carl-Zeiss-Str. 8 D-65520 Bad Camberg Phone: +49-(0)6434-9433-0 Hotline:

Mehr

miditech 4merge 4-fach MIDI Merger mit :

miditech 4merge 4-fach MIDI Merger mit : miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse

Mehr

Car operating panels and landing stations with the pushbutton system XL

Car operating panels and landing stations with the pushbutton system XL Tastensystem für barrierefreie Anwendungen (EN 81 70) pushbutton system for barrierfree applications (EN 81 70) System XL Kabinentableaus und Aussenrufe mit dem Tastensystem XL Car operating panels and

Mehr

Betriebsarten-Umschalter Common mode / Differential mode switch

Betriebsarten-Umschalter Common mode / Differential mode switch Betriebsarten-Umschalter Common mode / Differential mode switch Beschreibung: Der Betriebsarten-Umschalter CMDM 87 erweitert die Messmöglichkeiten zweier V-Netznachbildungen um die einer T- und Delta-Netznachbildung.

Mehr

Sampling Rate / Sample rate. Modulation (gem. DVB-Standard) Modulation (DVB standard) 16 QAM 256 QAM QPSK, 16 QAM, 64 QAM

Sampling Rate / Sample rate. Modulation (gem. DVB-Standard) Modulation (DVB standard) 16 QAM 256 QAM QPSK, 16 QAM, 64 QAM -Modulatoren modulators 1x in oder DVB-T Modulator zur Umsetzung eines -Signals in einen Kanal (QAM) oder in einen DVB-T Kanal (COFDM). Die Ausgangsmodulation kann über das Menü eingestellt werden. Der

Mehr

ÜBERSTRÖMVENTILE OVERFLOW VALVES. Type 618 T / Type 619 E for liquids, steam and gaseous media

ÜBERSTRÖMVENTILE OVERFLOW VALVES. Type 618 T / Type 619 E for liquids, steam and gaseous media ÜBERSTRÖMVENTILE UND REGELVENTILE OVERFLOW VALVES AND CONTROL VALVES Überström-/Regelventile aus Rotguss mit Nirofeder Overflow/control valves made of red brass with stainless steel spring Typ 618 T /

Mehr

Eclipse User Interface Guidelines

Eclipse User Interface Guidelines SS 2009 Softwarequalität 06.05.2009 C. M. Bopda, S. Vaupel {kaymic/vaupel84}@mathematik.uni-marburg.de Motivation (Problem) Motivation (Problem) Eclipse is a universal tool platform - an open, extensible

Mehr

Snom 3xx/7xx Serie. Manuelle Neukonfiguration. Dokumentenversion 1.0

Snom 3xx/7xx Serie. Manuelle Neukonfiguration. Dokumentenversion 1.0 Snom 3xx/7xx Serie Manuelle Neukonfiguration Dokumentenversion 1.0 Snom 3xx/7xx Serie Mauelle Neukonfiguration Copyright Hinweis Copyright 2016 finocom AG Alle Rechte vorbehalten. Jegliche technische Dokumentation,

Mehr

ZÜNDSTARTSCHALTER IGNITION STARTER SWITCHES

ZÜNDSTARTSCHALTER IGNITION STARTER SWITCHES ZÜNDSTARTSCHALTER IGNITION STARTER SWITCHES Zündstartschalter 32 70.. / 32 73.. / 32 74.. und Varianten Der Zündstartschalter mit Einklinkzylindern ist in drei verschiedenen Schaltvarianten lieferbar.

Mehr

lders dle ho ee ical n eed - ou n ndosurg rip yest e.. the ga fin. BEM N AD ELH A LTER / N EED LE H O LD ERS N ovem ber 2015

lders dle ho ee ical n eed - ou n ndosurg rip yest e.. the ga fin. BEM N AD ELH A LTER / N EED LE H O LD ERS N ovem ber 2015 ... BE the MA gri fine p yo st e u n ndo eed sur gic al n eed le h old ers N A D E L H A LT E R / N E E D L E H O L D E R S N ove m b e r 2 015 Integrale Nadelhalter Integrated needle holders Ø 5 mm /

Mehr

Montageanleitung DORMA PT 40. Winkeloberlichtbeschlag. Installation instruction DORMA PT 40. Patch fitting for overpanel and sidelight

Montageanleitung DORMA PT 40. Winkeloberlichtbeschlag. Installation instruction DORMA PT 40. Patch fitting for overpanel and sidelight Montageanleitung DORMA PT 40 Winkeloberlichtbeschlag Installation instruction DORMA PT 40 Patch fitting for overpanel and sidelight Stand/Issue 09.0 / 00331 00.5.37..3 Wichtige Informationen: Important

Mehr

Dear Colleague, Please give us a call and let us know how we can assist you. We look forward to talking to you soon. Thank you.

Dear Colleague, Please give us a call and let us know how we can assist you. We look forward to talking to you soon. Thank you. Dear Colleague, Thank you for visiting our website and downloading a product catalog from the R.M. Hoffman Company. We hope this information will be useful to you in solving the application you are working

Mehr

LED-Aluminium-Profil ELP A/K, ELP A/M, 15,2 x 6 mm LED Aluminium Profile ELP A/K, ELP A/M, 15,2 x 6 mm

LED-Aluminium-Profil ELP A/K, ELP A/M, 15,2 x 6 mm LED Aluminium Profile ELP A/K, ELP A/M, 15,2 x 6 mm LED-Aluminium-Profil ELP1-1000-A/K, ELP1-1000-A/M, 15,2 x 6 mm LED Aluminium Profile ELP1-1000-A/K, ELP1-1000-A/M, 15,2 x 6 mm LED-Aluminium-Profil, natur eloxiert, mit eingeschobener Kunststoffabdeckung

Mehr

TriASS Schreibtische. TriASS Schreibtischsystem Montageanleitung. TriASS Desking System Assembly Instructions. Das Assmann Prinzip. Gute Arbeit.

TriASS Schreibtische. TriASS Schreibtischsystem Montageanleitung. TriASS Desking System Assembly Instructions. Das Assmann Prinzip. Gute Arbeit. Das Assmann Prinzip. Gute Arbeit. TriASS Schreibtischsystem Montageanleitung TriASS Desking System Assembly Instructions The Assmann principle. Designed to work well. TriASS Desks Schreibtisch, Typ ST16

Mehr

NVR Mobile Viewer for iphone/ipad/ipod Touch

NVR Mobile Viewer for iphone/ipad/ipod Touch NVR Mobile Viewer for iphone/ipad/ipod Touch Quick Installation Guide DN-16111 DN-16112 DN16113 2 DN-16111, DN-16112, DN-16113 for Mobile ios Quick Guide Table of Contents Download and Install the App...

Mehr

Effizienz im Vor-Ort-Service

Effizienz im Vor-Ort-Service Installation: Anleitung SatWork Integrierte Auftragsabwicklung & -Disposition Februar 2012 Disposition & Auftragsabwicklung Effizienz im Vor-Ort-Service Disclaimer Vertraulichkeit Der Inhalt dieses Dokuments

Mehr

ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide

ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide 1 SET ALL1681 Upon you receive your wireless Router, please check that the following contents are packaged: - Powerline Wireless Router

Mehr

Printed Circuit Board Replacement for Sievers Model PPT TOC Analyzer

Printed Circuit Board Replacement for Sievers Model PPT TOC Analyzer Printed Circuit Board Replacement for Sievers Model PPT TOC Analyzer 1. Purpose 2. Scope Replace printed circuit boards (PCB s) in the Sievers Model PPT TOC analyzer. This procedure describes how to replace

Mehr

BECOscreen BERHALTER continously and efficiently screen changer

BECOscreen BERHALTER continously and efficiently screen changer T E C - S P I R A T I O N technology meets inspiration swiss made BECOscreen BERHALTER continously and efficiently screen changer your partner for melt filtration system screenchanger BERHALTER BECOscreen

Mehr

Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna

Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna Beschreibung: Die STLP 9129 ist eine gestockte Log.-Per.- Breitband Antenne für Störfestigkeitsprüfungen im Frequenzbereich von

Mehr

Pneumatic linear actuator - series MSR with cylinder Pneumatischer Linearantrieb Serie MSR mit Zylinder

Pneumatic linear actuator - series MSR with cylinder Pneumatischer Linearantrieb Serie MSR mit Zylinder Technische Eigenschaften: - Betriebsdruck: 2-8 bar - Wiederholgenauigkeit: 0.05 mm mit einstellbarem Hub - Betriebstemperatur: 5 C bis 60 C - Antrieb: durch integrierten Zylinder - Gehäus: hartbeschichtete

Mehr