technical documents for extraction and filter devices type series 1000

Größe: px
Ab Seite anzeigen:

Download "technical documents for extraction and filter devices type series 1000"

Transkript

1 technical documents for extraction and filter devices type series suction flange 6. filter combination 7. fan / motor 8. air outlet Functional principle: A special fan (3) with a high pressure stand-by creates an air flow adapted to the respective application at the clean room side of the filter cassette (2). The hazardous air is consistently extracted (1) and cleaned. The standard loaded filter indicator lights up if the filter is clogged. Because of the high purity of the filtered air it can be supplied back to the shop floor (4) helping to cut energy costs. The different filters are combined within the device and can be replaced singularly. The filter is recyclable. ULT Umwelt-Lufttechnik Internet: ult@ult.de Telefon (0) / Telefax / (0) /

2 technical documents for extraction and filter devices type series 1000 Technical specification / fan characteristics: type series V parameter unit max. flow rate m³/h max. vacuum Pa nominal capacity m³/h bei Pa / / nominal motor power kw 1,5 1,5 nominal voltage V nominal currency A 3,5 3,5 frequency Hz protection mode IP noise level at 50% db(a) noise level at 100% db(a) weight kg flow rate controller optional loaded filter indicator optional operating hours meter optional suction flange mm on request air outlet grating or outlet flange ULT Umwelt-Lufttechnik Internet: ult@ult.de Telefon (0) / Telefax / (0) /

3 power switch minimum flow rate indicator suction flange filter door 680 power connection 1215 air outlet air inlet adsorption filter fan LRA 1000-M 2003 Datum Name ULT LRA 1000-M..\sicher\Reichmann\alt_d\ULT\Geräteun..\Zeichn..\LRA\LRA 1000-M.tcw

4 2003 Datum Name ULT ULT ULT ULT adsorption filter - new ULT adsorption filter - exchange ULT LRA 1000-M spare and wear parts ULT LRA 1000-M (EZ)

5 filter door air outlet suction flange adsorption filter fan operating elements in separate control box all components have the same electric potential through earthing connections LRA 1000 EX-M 2003 Datum Name ULT LRA 1000 EX-M..\sicher\Reichmann\alt_d\ULT\Geräteun..\Zeichn..\LRA\LRA 1000 EX-M.tcw

6 filter door ULT ULT ULT ULT adsorption filter - new ULT adsorption filter - exchange ULT operating elements in separate control box all components have the same electric potential through earthing connections LRA 1000 EX-M spare and wear parts 2003 Datum Name ULT LRA 1000 EX-M (EZ)

7 flow rate controller power switch loaded filter indicator filter door 680 power connection air outlet suction flange adsorption filter fan LRA 1000-VF 2003 Datum Name ULT LRA 1000-VF..\sicher\Reichmann\alt_d\ULT\Geräteun..\Zeichn..\LRA\LRA 1000-VF.tcw

8 filter door 2003 Datum Name ULT ULT ULT ULT adsorption filter - new ULT adsorption filter - exchange ULT LRA 1000-VF spare and wear parts ULT LRA 1000-VF (EZ)..\sicher\Reichmann\alt_d\ULT\Geräteun..\Zeichn..\LRA\LRA 1000-VF(EZ).tcw

technical documents for extraction and filter devices type series 220

technical documents for extraction and filter devices type series 220 technical documents for extraction and filter devices type series 220 1. suction flange 2. filter cassette 3. motor / fan 4. power switch 5. air outlet Functional principle: A special fan (3) with a high

Mehr

ULT JUMBO Filtertrolley 2.0 MED

ULT JUMBO Filtertrolley 2.0 MED ULT JUMBO Filtertrolley 2.0 MED Technical Documentation for Extraction and Filter Unit Type Series Jumbo MED During medical applications like laser surgery, electrocautery and others hazardous surgical

Mehr

X-ROW G X-ROW 60 G X-ROW 80 G X-ROW 100 G X-ROW 120 G X-ROW 170 G X-ROW 230 G X-ROW 300 G X-ROW 370 G X-ROW 460 G. Kompressoren. 50 Hz Auswahldiagramm

X-ROW G X-ROW 60 G X-ROW 80 G X-ROW 100 G X-ROW 120 G X-ROW 170 G X-ROW 230 G X-ROW 300 G X-ROW 370 G X-ROW 460 G. Kompressoren. 50 Hz Auswahldiagramm Kompressoren X-OW G X-OW 60 G X-OW 80 G X-OW 100 G X-OW 120 G X-OW 170 G X-OW 230 G X-OW 300 G X-OW 370 G X-OW 460 G Öl umlaufgeschmierte Drehschieber-Kompressoren mit Wasserkühlung für die Verdichtung

Mehr

Zehnder ComfoWell 320

Zehnder ComfoWell 320 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with locking slides for

Mehr

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten. EZ-0225-V10 Air Bearing Spindle High accurancy air bearing spindle with direct drive. Equipped with an water-cooled synchronous motor (frequency at nominal speed 400 Hz), Power output 1880 W. Rotary encoder

Mehr

Cleanroom Fog Generators Volcano VP 12 + VP 18

Cleanroom Fog Generators Volcano VP 12 + VP 18 Cleanroom Fog Generators Volcano VP 12 + VP 18 Description & Functional Principle (Piezo Technology) Cleanrooms are dynamic systems. People and goods are constantly in motion. Further installations, production

Mehr

Zehnder ComfoWell 220

Zehnder ComfoWell 220 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for

Mehr

Luftfördermenge / Air flow: (m³/h)

Luftfördermenge / Air flow: (m³/h) Filterlüfter Filter Fan LV 25 Technische Daten / Technical data: Type: LV 25 Spannung Voltage Stromaufnahme Amperage Leistung Power input Drehzahl Speed Temperaturbereich Temperature range Lebensdauer

Mehr

Hazards and measures against hazards by implementation of safe pneumatic circuits

Hazards and measures against hazards by implementation of safe pneumatic circuits Application of EN ISO 13849-1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free

Mehr

Vacuum. Vakuum. Modul 3 Module 3 155

Vacuum. Vakuum. Modul 3 Module 3 155 Auswahldaten Schrauben-pumpen Selection data for screw vacuum pumps 154-161 Reihe VSA VSA range 156-157 Reihe VSB VSB range 158-159 Reihe VSI VSI range 160-161 Modul 3 Module 3 155 VSA VSA 150 (30) 330

Mehr

Attenuator and Distribution System Zehnder ComfoWell 220

Attenuator and Distribution System Zehnder ComfoWell 220 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for

Mehr

The future of snow. The silent hero of snow guns

The future of snow. The silent hero of snow guns The future of snow The silent hero of snow guns EN 4 Maximum snow production. Minimum noise level. High energy efficiency. Performance was never so quiet. All the appreciated features of TITAN with a

Mehr

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Serie Series L-BV2 L_200 Flüssigkeitsringpumpen Liquid ring pumps 3 AC; 50/60 Hz 3 AC; 50/60 Hz Vakuumbetrieb Vacuum operation Typen Types 2BV2

Mehr

Zehnder CLD. Housing for walls, floors and ceilings

Zehnder CLD. Housing for walls, floors and ceilings Benefits Suitable for wall, floor or ceiling installation Air volumes up to a maximum of 30 m 2 /h (ComfoTube 75) and 45 m 2 /h (ComfoTube 90) Can be installed in timber or solid constructions Extract

Mehr

Überdruck bar. X-ROL bar bar bar Volumenstrom

Überdruck bar. X-ROL bar bar bar Volumenstrom X-ROL topline X-ROL 50 X-ROL 65 X-ROL 75 X-ROL 85 X-ROL 120 X-ROL 150 Kompressoren Öl umlaufgeschmierte Drehschieber-Kompressoren für Luft. Ausführungen mit Luftkühlung. Volumenströme von 253 bis 946 m³/h,

Mehr

OIL-FREE MEDICAL compressors

OIL-FREE MEDICAL compressors OIL-FREE MEDICAL compressors AIR FOR LIFE DK50 DS BASIC STANDARD ADVANCED kleiner und kompakter Medizinkompressor small and compact medical compressor ALARM Temperatur Druck Strom ALARMS temperature pressure

Mehr

Attenuator and Distribution System Zehnder ComfoWell 520

Attenuator and Distribution System Zehnder ComfoWell 520 Attenuator and Distribution System Zehnder ComfoWell 520 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy

Mehr

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T Startfolie B/S/H/ 1 Product division Event Location Refrigeration Side by Side USA B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T 2 Side-by-Side Appliances Models: Bosch Siemens KAN 56V** KAN58A** KA58NA**with

Mehr

Quadt Kunststoffapparatebau GmbH

Quadt Kunststoffapparatebau GmbH Quadt Kunststoffapparatebau GmbH Industriestraße 4-6 D-53842 Troisdorf/Germany Tel.: +49(0)2241-95125-0 Fax.: +49(0)2241-95125-17 email: info@quadt-kunststoff.de Web: www.quadt-kunststoff.de Page 1 1.

Mehr

Attenuator and Distribution System Zehnder ComfoWell 320

Attenuator and Distribution System Zehnder ComfoWell 320 Attenuator and Distribution System Zehnder ComfoWell 32 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy

Mehr

KB2000/KB2000S PARTS MANUAL. Morgana Systems Limited United Kingdom Telephone: ( ) Facsimile: ( )

KB2000/KB2000S PARTS MANUAL. Morgana Systems Limited United Kingdom  Telephone: ( ) Facsimile: ( ) KB2000/KB2000S PARTS MANUAL Morgana Systems Limited United Kingdom www.morgana.co.uk Telephone: ( 01908 ) 608888 Facsimile: ( 01908 ) 692399 Ersatzteilkatalog Spare parts catalogue PrintBind KB-2000 77.1250

Mehr

Dach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE

Dach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE Dach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE 4-8 Optimale Luftführung im Schaltschrank Montage und Filterwechsel ohne Werkzeug Gleiche e wie Filterlüfter LV Geringe Einbautiefe

Mehr

Counterflow Heat Recovery Fan

Counterflow Heat Recovery Fan Counterflow Heat Recovery Fan Dr. Christoph Speer, MSc Unit for Energy Efficient Buildings, University Innsbruck, Austria Existing Principle Combination of Fan and Heat Exchanger Principle: rotating porous

Mehr

Pressure Vacuum. Druck-Vakuum

Pressure Vacuum. Druck-Vakuum Druck-Vakuum Auswahldaten Drehschieber-Druck-Vakuumpumpen Selection data for rotary vane pressure vacuum pumps 74-83 Reihe KLT KLT range 76-77 Reihe KTA KTA range 78-81 Reihe KTR KTR range 82-83 Modul

Mehr

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Newest Generation of the BS2 Corrosion/Warning and Measurement System Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing

Mehr

V-VC 50 75 100 150. 60 Hz. 50 Hz

V-VC 50 75 100 150. 60 Hz. 50 Hz V-VC 50 75 100 150 Ölüberflutete Drehschieber-Vakuumpumpe mit Saugvermögen 50 bis 180 m³/h, max. Endvakuum 0,1 mbar (abs.). Flanschmotor, doppelseitige Rotorlagerung, Öl/Luftkühler. Feinsiebfilter, saugseitiges

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Linn-Pumpen GmbH. Gewerbering 15 D Schalksmühle Telefon: +49 (0) Telefax: +49 (0)

Linn-Pumpen GmbH. Gewerbering 15 D Schalksmühle Telefon: +49 (0) Telefax: +49 (0) inn-n GmbH GS Unterwassermotorpumpen für 4" - Tiefbrunnen GS Submersible s for 4 Wells Anwendungsbereiche - Wasserversorgungsanlagen - Beregnungsanlagen - Druckerhöhungsanlagen - Feuerlöschanlagen Technische

Mehr

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series 3/2-way, G 1/4, Technical data for series -310-311 -312-320 -320-Q -322-322-Q Design and function Pneumatically operated spool valve. The valve switches upon pressurization of the pilot port (10 or 12).

Mehr

X-L GK X-L 20 GK X-L 30 GK X-L 40 GK X-L 50 GK X-L 75 GK X-L 100 GK. Kompressoren. Auswahldiagramm

X-L GK X-L 20 GK X-L 30 GK X-L 40 GK X-L 50 GK X-L 75 GK X-L 100 GK. Kompressoren. Auswahldiagramm Kompressoren X-L GK X-L 20 GK X-L 30 GK X-L 40 GK X-L 50 GK X-L 75 GK X-L 100 GK Luftgekühlte, frischölgeschmierte Drehschieber-Kompressoren mit Volumenströmen von 120 bis 540 m³/h und etriebsüberdrücke

Mehr

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC Oil / Air cooler ASATT 11 12V/24V DC Öl /Luftkühler ASATT 11 12V/24V DC Pressure drop at 30 cst Druckabfall bei 30 cst Specific Cooling Performance Spezifische Kühlleistung TECHNICAL DATA TECHNISCHE DATEN

Mehr

PrintBind KB Ersatzteilkatalog Spare parts catalogue

PrintBind KB Ersatzteilkatalog Spare parts catalogue Ersatzteilkatalog Spare parts catalogue PrintBind KB-2000 FKS-Hamburg Ing. Fritz Schroeder GmbH & Co. KG Neumann-Reichardt-Str. 36-38 22041 Hamburg Tel. +49 0 40 736077-0 Fax +49 0 40 736077-22 Email info@fks-hamburg.de

Mehr

Walter Buchmayr Ges.m.b.H.

Walter Buchmayr Ges.m.b.H. Seite 1/10 Chapter Description Page 1 Advantages 3 2 Performance description 4 3 Settings 5 4 Options 6 5 Technical data 7 6 Pictures 8 http://members.aon.at/buchmayrgmbh e-mail: walter.buchmayr.gmbh@aon.at

Mehr

Lüften - Filtern - Heizen

Lüften - Filtern - Heizen CompactAIR Center Lüften - Filtern - Heizen CompactAIR Center Ventilation - Filtration - Heating Typenschlüssel / Type Code CompactAIR 28 CompactAIR / CompactAIR Laufraddurchmesser / diameter of impeller

Mehr

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,

Mehr

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012 Heaters for Enclosures SM 10-45 - Selbstregelnde PTC-Heizungen mit 10-45 W - Optimiertes Profil mit verbesserter Heizleistung und geringerer Oberflächentemperatur - Montage und Anschluss ohne Werkzeug

Mehr

PLATIN-LINE KOMPRESSOREN

PLATIN-LINE KOMPRESSOREN - 2 5 ( S ), R O - 3 V /5V/10V, PLATIN-LINE KOMPRESSOREN i, P I - 1 2 0-4 / P I - 120-25 ( S ), R O - 3 V / 5 V /10V, PI P I - 9 0 / 1 2 0 / 1 8 0/200 HV - 4 0 / 9 0 / 1 2 0 / 1 80/ 200C - 4 0 / 9 0 /

Mehr

Standardausführung standard version. Merkmale. Features

Standardausführung standard version. Merkmale. Features Riegelkurve EMT 17 und EMT 18 Retiring Cam EMT 17 and EMT 18 Standardausführung standard version Merkmale alle Stahlteile verzinkt geräuscharm durch starke Dämpfung beim Ein- und Ausschalten robust und

Mehr

Pressure. Druck. Modul 3 Module 3 65

Pressure. Druck. Modul 3 Module 3 65 Druck Auswahldaten Drehschieberverdichter Selection data for rotary vane compressors 64-73 Reihe DTE DTE range 66-67 Reihe DLT DLT range 68-69 Reihe DTA DTA range 70-71 Reihe DTR DTR range 72-73 Modul

Mehr

HITACHI. New Issue of Spare Parts List for Multi-Split System Heat Pump Air Conditioners, 4-way Cassette Type Indoor Units -RCIM-FSN2 Series-

HITACHI. New Issue of Spare Parts List for Multi-Split System Heat Pump Air Conditioners, 4-way Cassette Type Indoor Units -RCIM-FSN2 Series- ERSATZTEILE RCIM-1.0_2.0FSN2 / P-N23WAM SERVICE PARTS NEWS SUBJECT HITACHI New Issue of Spare Parts List for Multi-Split System Heat Pump Air Conditioners, 4-way Cassette Type Indoor Units -RCIM-FSN2 Series-

Mehr

Saugfördergerät SFG Vacuum hopper loader SFG

Saugfördergerät SFG Vacuum hopper loader SFG Produktinformation Product information Einsatzgebiete Universelles Gerät zur automatischen Beschickung von Extrudern, Ver arbeitungsmaschinen, Behältern und Lagersilos mit Pulvern und Granulaten mit Pulveranteil.

Mehr

Lüfter Fans. Finger-shaped Attachable Extruded. with solderpins. standard length. Extruded. Die-cast Profiles Mounting.

Lüfter Fans. Finger-shaped Attachable Extruded. with solderpins. standard length. Extruded. Die-cast Profiles Mounting. Lüfter Fans Finger-shaped Attachable ASSMANN WSW components, Hersteller und Systemanbieter für Kühlkörper, Steckverbinder und Kabelkonfektion bietet ein breites Spektrum an unterschiedlichen Lüftern an.

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Certificate of conformity Generating unit, NS-protection Applicant: Product: Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

Electrical testing of Bosch common rail solenoid valve (MV) injectors

Electrical testing of Bosch common rail solenoid valve (MV) injectors Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445

Mehr

ZnO-Arresters for Overvoltage Protection in Pulsed Power Circuits

ZnO-Arresters for Overvoltage Protection in Pulsed Power Circuits European Electromagnetic Launch Society 12th Topical Meeting 10th to 12th September 2001, Ayr ZnO-Arresters for Overvoltage Protection in Pulsed Power Circuits Ulrich Braunsberger Institut für Hochspannungstechnik

Mehr

UV-MASTER. Härtung von Foliendekoroberflächen mit UV-Strahlung UV-Curing of film decorated mold parts (IMD/IML)

UV-MASTER. Härtung von Foliendekoroberflächen mit UV-Strahlung UV-Curing of film decorated mold parts (IMD/IML) UV-MASTER Härtung von Foliendekoroberflächen mit UV-Strahlung UV-Curing of film decorated mold parts (IMD/IML) OBERFLÄCHEN-REINIGUNGS-SYSTEME SURFACE-CLEANING-SYSTEMS UV-MASTER UV-HÄRTUNG von Design-Folien

Mehr

VGA VGA Hz Auswahldiagramm Selection diagram 60 Hz Auswahldiagramm Selection diagram

VGA VGA Hz Auswahldiagramm Selection diagram 60 Hz Auswahldiagramm Selection diagram VGA VGA 4 6 Ölüberflutete Drehschieber-Vakuumpumpe mit Saugvermögen 4 bis 7,2 m³/h, max. Endvakuum 20 mbar (abs.). Geringer Platzbedarf durch einseitige Rotorlagerung, integrierter Motor, Luftkühlung,

Mehr

D12 Tel. +49 (0)7081 / Fax +49 (0)7081 / Quattro LNBs. Ausgänge bei Teilnehmern. Outlets to receivers

D12 Tel. +49 (0)7081 / Fax +49 (0)7081 / Quattro LNBs. Ausgänge bei Teilnehmern. Outlets to receivers A Kopfstellen Headends Green Line Multischalter 13 Eingänge Green Line Multiswitches 13 inputs B Modulatoren Modulators Quattro LNBs PAS 28113 N C Optische Geräte Optical devices PSG 1308 C Kaskaden-Multischalter

Mehr

HVDC and FACTS. Flexible Alternative Current Transmission Systems. Modul in Studiengängen Elektrotechnik und Energiewirtschaft

HVDC and FACTS. Flexible Alternative Current Transmission Systems. Modul in Studiengängen Elektrotechnik und Energiewirtschaft Page No 1 of 16 HVDC and FACTS HVDC FACTS High Voltage Direct Current Flexible Alternative Current Transmission Systems Modul in Studiengängen Elektrotechnik und Energiewirtschaft Zeitraum: SS 2017 Umfang:

Mehr

Electrical testing of Bosch common rail piezo injectors

Electrical testing of Bosch common rail piezo injectors Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid

Mehr

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren Hochpotenzial - Hochspannungs - Trenntransformatoren pri - sec und einer Leistung von 1 VA bis 3000 VA Isoliertrafo, Isolationstransformator Einsatzmöglichkeiten Hochspannungstrenntransformatoren werden

Mehr

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Operation Guide AFB 60. Zeiss - Str. 1 D-78083 Dauchingen

Operation Guide AFB 60. Zeiss - Str. 1 D-78083 Dauchingen Operation Guide AFB 60 Zeiss - Str. 1 D-78083 Dauchingen PCB automation systems AFB 30/60/90 Die flexiblen Puffer der Baureihe AFB werden zwischen zwei Produktionslinien eingesetzt, um unterschiedliche

Mehr

ORION three-phase 2-250kVA

ORION three-phase 2-250kVA ORION three-phase 2-250kVA Orion stabilizers are available for different ranges of input voltage fluctuation. Standard models offer a double input connection so that with the same unit two different input

Mehr

TKreiselpumpen Typ T. Centrifugal pumps type T

TKreiselpumpen Typ T. Centrifugal pumps type T TKreiselpumpen Typ T Centrifugal pumps type T Eigenschaften. Properties.. Sehr hoher Wirkungsgrad durch strömungstechnisch günstig geformtes Laufrad Very high efficiency because of flow favorable formed

Mehr

UWC 8801 / 8802 / 8803

UWC 8801 / 8802 / 8803 Wandbedieneinheit Wall Panel UWC 8801 / 8802 / 8803 Bedienungsanleitung User Manual BDA V130601DE UWC 8801 Wandbedieneinheit Anschluss Vor dem Anschluss ist der UMM 8800 unbedingt auszuschalten. Die Übertragung

Mehr

2/2-way solenoid valve - Type 218

2/2-way solenoid valve - Type 218 - direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Zeroboxen Evolution und Ultimate. Zeroboxes Evolution and Ultimate. Zeroboxen / Zeroboxes. Typenschlüssel / Type Code U Z 160 E 1.

Zeroboxen Evolution und Ultimate. Zeroboxes Evolution and Ultimate. Zeroboxen / Zeroboxes. Typenschlüssel / Type Code U Z 160 E 1. eroboxen / eroboxes eroboxen Evolution und Ultimate eroboxes Evolution and Ultimate Typenschlüssel / Type Code U 16 E 1 erobox / erobox Rohranschlußdurchmesser / diameter of tube connection E = Baureihe

Mehr

Zeroboxen Evolution und Ultimate. Zeroboxes Evolution and Ultimate. Zeroboxen / Zeroboxes. Typenschlüssel / Type Code U Z 160 E 1.

Zeroboxen Evolution und Ultimate. Zeroboxes Evolution and Ultimate. Zeroboxen / Zeroboxes. Typenschlüssel / Type Code U Z 160 E 1. eroboxen / eroboxes eroboxen Evolution und Ultimate eroboxes Evolution and Ultimate Typenschlüssel / Type Code U 16 E 1 erobox / erobox Rohranschlußdurchmesser / diameter of tube connection E = Baureihe

Mehr

Renova B-Air BRENNZELLE/ KACHELOFENEINSATZ. fireplace insert. Glasform: pane design: Renova B-Air 1. Renova B-Air mit Frontblende RB3.

Renova B-Air BRENNZELLE/ KACHELOFENEINSATZ. fireplace insert. Glasform: pane design: Renova B-Air 1. Renova B-Air mit Frontblende RB3. BRENNZELLE/ KACHELOFENEINSATZ fireplace insert Renova B-Air Renova B-Air mit Frontblende RB3.0 Glasform: pane design: Renova B-Air 1 Technische Zeichnungen Renova B-Air mit Mauerhalszarge engineering drawing

Mehr

Shock pulse measurement principle

Shock pulse measurement principle Shock pulse measurement principle a [m/s²] 4.0 3.5 3.0 Roller bearing signals in 36 khz range Natural sensor frequency = 36 khz 2.5 2.0 1.5 1.0 0.5 0.0-0.5-1.0-1.5-2.0-2.5-3.0-3.5-4.0 350 360 370 380 390

Mehr

Photo: konradmuranski-fotolia.com

Photo: konradmuranski-fotolia.com SILVERLINE Kompressoren i Photo: konradmuranskifotolia.com SILVERLINE LS204, LS4, LS15, LS25, LS10025, LS100, LS1, LS200, LS300100, OFS4, OFS904, OFS9015, OFS9025 / SILVERLINE LS204, LS4, LS15, LS25, LS10025,

Mehr

Bedienungsanleitung. User Manual

Bedienungsanleitung. User Manual Bedienungsanleitung Seite: -3 User Manual LightmaXX 5ive STAR LED LIG0009669-000 Page: 4-5 Lieber Kunde, vielen Dank das Sie sich für ein Produkt von LightmaXX entschieden haben. In der folgenden Anleitung

Mehr

Serviceinformation Nr. 02/11

Serviceinformation Nr. 02/11 Serviceinformation Nr. 02/11 vom: 06.10.2011 von: BAM 1. Software Navigator und Release Notes Auf unserer Homepage unter www.idm-energie.at/de/navigator-software.html steht ab sofort eine neue Version

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff

Mehr

C612 - C912. form 1 2 2a 3 IMB3 ) * IMB6 * ) IMB7 ) * IMB8 IMV5 * )

C612 - C912. form 1 2 2a 3 IMB3 ) * IMB6 * ) IMB7 ) * IMB8 IMV5 * ) Montagehinweis Schmierarmaturen für STÖBER MGS Getriebe C de ID 446.0 Seite von 6 Kieselbronner Straße 7577 Pforzheim Postfach 900 7509 Pforzheim Phone +49 7 58-0 Fax +49 7 58-000 Allgemeine Hinweise:

Mehr

Daten Visualisierung - VS -

Daten Visualisierung - VS - Technische Spezifikationen TECHNISCHE SPEZIFIKATIONEN DATENBLÄTTER - VS - Änderungen im Sinne des technischen Fortschritts vorbehalten Technische Spezifikationen 2008 VS-00 Technische Specifikation EX

Mehr

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar] NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,

Mehr

LIFTKET electric chain hoists in use worldwide

LIFTKET electric chain hoists in use worldwide 2 LIFTKET electric chain hoists in use wldwide Production progam» Electric chain hoists 125 kg 6300 kg» Electric chain hoists 4000 kg 25000 kg» Electric chain hoists f special requirements» Electric chain

Mehr

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

Pneumatic linear actuator - series MSR with cylinder Pneumatischer Linearantrieb Serie MSR mit zylinder

Pneumatic linear actuator - series MSR with cylinder Pneumatischer Linearantrieb Serie MSR mit zylinder Technische Eigenschatften: - Range of operating pressure: 2-8 bar - Accuracy repeability: 0.05mm with adjustable stroke - Operating temperature: 5 C to 60 C - Operating system: through internal cylinder

Mehr

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H Rotary Dampers with high-torque range WRD-H 67 WRD-H 85 WRD-H 128 WRD-H 161 WRD-H 21 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Applications: - Mechanical and

Mehr

Stahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting

Stahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting Stahlgitterwiderstandselemente Steel Grid Resistor lements 500 W für inbau 500 W for fitting Stahlgitterwiderstandselemente RSW RSW 54 500 W für inbau Steel Grid Resistor lements RSW to RSW 54 500 W for

Mehr

TKreiselpumpen Typ T. Centrifugal pumps type T

TKreiselpumpen Typ T. Centrifugal pumps type T TKreiselpumpen Typ T Centrifugal pumps type T Eigenschaften. Properties.. Sehr hoher Wirkungsgrad durch strömungstechnisch günstig geformtes Laufrad Very high efficiency because of flow favorable formed

Mehr

TECHNICAL DATA SHEET Member of Uponor Group

TECHNICAL DATA SHEET Member of Uponor Group TECHNICAL DATA SHEET Member of Uponor Group Fresh water unit FWS-V HE FWS-V-6 HE-3 FWS-V-8 HE-3 Equipment example with process water circulation B E A C D Hydraulic diagram D C E A B A B C D E Drinking

Mehr

Umschaltventile Magnete

Umschaltventile Magnete Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC

Mehr

Filterline Typ. Filterline

Filterline Typ. Filterline GB Complete and space saving Plug & Play filter unit Differential pressure controlled compressed air cleaning Digital differential pressure display Pressure tank with manometer built into cabinet Possibility

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

Auszug aus dem LED-Katalog 03/2017 Extract from the LED catalogue 03/2017 AIR MAXX. Wandleuchten / Wall luminaires

Auszug aus dem LED-Katalog 03/2017 Extract from the LED catalogue 03/2017 AIR MAXX. Wandleuchten / Wall luminaires Auszug aus dem LED-Katalog 03/2017 Extract from the LED catalogue 03/2017 AIR MAXX Wandleuchten / Wall luminaires 414 415 436 AIR MAXX 250 POWER AIR MAXX 432 AIR MAXX 130 POWER 438 AIR MAXX 250 POWER 428

Mehr

Cabinets for absolute filters. Gehäuse für Schwebstoff-Filter Typ

Cabinets for absolute filters. Gehäuse für Schwebstoff-Filter Typ Cabinets for absolute filters AF Gehäuse für Schwebstoff-Filter Typ AF 1M7 AF 2 Cabinet AF 1M7 Standard filter frame for absolute filter: Combination possibilities (see next page) with: - Legs - Connection

Mehr

Wegeventile EHF/EHP Sectional Valves

Wegeventile EHF/EHP Sectional Valves Wegeventile EHF/EHP Sectional Valves Technische Daten Technical Specifications Kenngrößen Parameters Nenndurchfluss (max. Durchfluss) Nominal flow rate (max. flow rate) Max. Druck max. pressure rate Max.

Mehr

Technical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00)

Technical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00) Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00) Inhalt S./P. 1. Beschreibung /

Mehr

KR Die KLEMM KR wurde speziell für Pfahlbohrungen im Durchmesserbereich von 356 mm bis 600 mm entwickelt.

KR Die KLEMM KR wurde speziell für Pfahlbohrungen im Durchmesserbereich von 356 mm bis 600 mm entwickelt. Die KLEMM KR 709-1 wurde speziell für Pfahlbohrungen im Durchmesserbereich von 356 mm bis 600 mm entwickelt. Eine hohe Bohrleistung wird durch die neue Bohrlafette 202/13 (13 t Rückzugkraft) und den Drehantrieb

Mehr

Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit Pool water quality the German philosophy

Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit Pool water quality the German philosophy Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit Pool water quality the German philosophy Christiane Höller Bavarian Health and Food Safety Authority Legal regulations 1979 Federal Law on

Mehr

Umschaltventile Magnet

Umschaltventile Magnet Umschaltventile Magnet DFE1/3 estellnr. Typ 2-11-1 DFE1/318ES-W22-12VDC 2-11-1 DFE1/318ES-W22-24VDC 24-2-116 DFE1/318ES-Y22-12VDC 24-2-117 DFE1/318ES-Y22-24VDC Weitere Umschaltventil Varianten auf nfrage

Mehr

Deutsch: REPARATURANWEISUNG

Deutsch: REPARATURANWEISUNG DE: Diese Anweisung ist in zwei Sprachen verfügbar. ENG: This instruction is available in two languages. Deutsch: REPARATURANWEISUNG English: REPAIR INSTRUCTION Dok.-Nr. RA L4.00-00 Sprachen-2-Deckblatt

Mehr

SICHERHEITSVENTILE OHNE BAUTEILPRÜFUNG SAFETY VALVES WITHOUT TEST CERTIFICATE. Type 602 E / Type 601 T for liquids, gaseous media and steam

SICHERHEITSVENTILE OHNE BAUTEILPRÜFUNG SAFETY VALVES WITHOUT TEST CERTIFICATE. Type 602 E / Type 601 T for liquids, gaseous media and steam Ecksicherheitsventile aus Rotguss Angular safety valves made of red brass Typ 602 E / Typ 601 T für Flüssigkeiten, gasförmige Medien und Dampf Type 602 E / Type 601 T for liquids, gaseous media and steam

Mehr

Bosch Rexroth - The Drive & Control Company

Bosch Rexroth - The Drive & Control Company Bosch Rexroth - The Drive & Control Company Alle Rechte bei Bosch Rexroth AG, auch für den Fall von Schutzrechtsanmeldungen. Jede Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns. 1 Case study

Mehr

Motorenreihe IE3 / Premium Effizienz

Motorenreihe IE3 / Premium Effizienz Premium IE3 - Motorenreihe IE3 / Premium Effizienz Motor line IE3 / Premium efficiency Eckdaten Key data n s Gehäusematerial Frame material Polzahl Number of poles Output 80 bis 315 80 to 315 Aluminium

Mehr

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen Technical Report No. 028-71 30 95685-350 of 22.02.2017 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen

Mehr

Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 5,5 2 Pol Leistung/ power: W

Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 5,5 2 Pol Leistung/ power: W Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 5,5 2 Pol Leistung/ power: 10 125 W ESTAN Elektromaschinen und Steuerungsbau GmbH Burgunderstraße 6 D-79418 Schliengen (Germany) 1 Tel:

Mehr

BROEN BALLOMAX PN40, DN 15-50

BROEN BALLOMAX PN40, DN 15-50 Dealing with forces of nature BROEN BALLOMAX PN40, DN 15-50 Auf Wunsch auch mit Knebelgriff. Available with T-handle upon request. Beidseitig Flansche Vollverschweißter Stahlkugelhahn Materialbeschreibung

Mehr

Type TS FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVZ, TVA, TZ-SILENZIO, TA-SILENZIO OR TVM

Type TS FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVZ, TVA, TZ-SILENZIO, TA-SILENZIO OR TVM Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Secondary silencer > Type TS Type TS FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS

Mehr

SEITENKANALVERDICHTER, DRUCK- UND VAKUUMBETRIEB CL Serie und Typ TBT. SIDE CHANNEL BLOWERS AND EXHAUSTERS CL Series and TBT Type

SEITENKANALVERDICHTER, DRUCK- UND VAKUUMBETRIEB CL Serie und Typ TBT. SIDE CHANNEL BLOWERS AND EXHAUSTERS CL Series and TBT Type SEITENKANALVERDICHTER, DRUCK- UND VAKUUMBETRIEB CL Serie und Typ TBT SIDE CHANNEL BLOWERS AND EXHAUSTERS CL Series and TBT Type SEITENKANALVERDICHTER - CL Serie SIDE CHANNEL MACHINES - CL Series Arbeitsweise

Mehr

Rohrventilatoren aus Kunststoff oder Stahl. Tube fans made of plastic or steel. Rohrventilatoren / Tube Fans. Typenschlüssel / Type Code R S 315 L

Rohrventilatoren aus Kunststoff oder Stahl. Tube fans made of plastic or steel. Rohrventilatoren / Tube Fans. Typenschlüssel / Type Code R S 315 L Rohrventilatoren aus Kunststoff oder Stahl Tube fans made of plastic or steel Typenschlüssel / Type Code R S 315 L Rohrventilator / tube fan Kunststoffgehäuse 8-eckig / plastic casing 8-angular Rohrdurchmesser

Mehr

Filterline Typ. Filterline

Filterline Typ. Filterline Complete and space saving Plug & Play filter unit ifferential pressure controlled compressed air cleaning igital differential pressure display Pressure tank with manometer built into cabinet Possibility

Mehr

Öl-Luft-Kühlaggregate, Serie CPR Oil-Air-Cooler-Units, Series CPR

Öl-Luft-Kühlaggregate, Serie CPR Oil-Air-Cooler-Units, Series CPR Öl-Luft-Kühlaggregate, Serie CPR Oil-Air-Cooler-Units, Series CPR Kühl/Filtereinheit im Bypass-Betrieb Die geräuscharme Lösung mit Radiallüfter Geräuschpegel < 70 db(a) bei 1 m Abstand Kühlleistungsbereich

Mehr

DATENBLATT / DATASHEET

DATENBLATT / DATASHEET DATENBLATT / DATASHEET AEQUILUX DMX PLAYER 1024 / 2048 Abb. Ähnlich Illustration similar BESCHREIBUNG / DESCRIPTION Der AEQUILUX DMX Player dient zur Lichtsteuerung des AEQUILUX Systems. Das Gerät kann

Mehr

servogesteuert pilot operated

servogesteuert pilot operated 1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung

Mehr