TECNAC CO2 PRODUKTE Técnicas Ambientales del Centro S.L.

Größe: px
Ab Seite anzeigen:

Download "TECNAC CO2 PRODUKTE Técnicas Ambientales del Centro S.L."

Transkript

1 Técnicas Ambientales del Centro S.L. 1 CO2 PRODUKTE Dieser Katalog ist speziell für CO2 (komple e Katalog auf unserer Website: ) 1

2 2 CO2 APPLICATION SUBCRITICAL TRANSCRITICAL CO2 (secondary cycle of low temperature) + HFC refrigerant (tradi onal refrigerant in primary cicle to keep the condensa- ng temperature of the CO2 cycle below the cri cal point, usually between -5 and -10ºC) Refrigerant : only CO 2 Nega ve impact on the environment (emissions of HFC) High electrical consump on More load of refrigerant Higher cost of refrigerant (due to the HFC) Natural gas without environmental impact (does not damage the ozone layer) Energy saving Less load of refrigerant Lower cost of refrigerant REFRIGERATION DESIGN Working pressures un l 73 bar Working pressures un l 130 bar High pressure zone of the circuit below the cri cal point The temperature of the CO2 in the isothermal phase a er compression of the fluid is below the cri cal temperature High pressure zone of the circuit above the cri cal point The temperature of the CO2 in the gas cooler outlet is higher than 31ºC and, obviously, the evapora ng temperature is lower The refrigera on of the compressed gas corresponds to a condensa ng with constant temperature The refrigera on of the compressed gas does not corresponds to a condensa ng with constant temperature The CO2 condenses on the high-pressure side The CO2 cools on the high-pressure side, but does not condense,staying above the cri cal temperature 2

3 3 ANWENDUNG DES CO2 UNTERKRITISCHE ÜBERKRITISCHE CO 2 (Sekundärzyklus bei niedriger Temperatur) + FKW (tradi onelles Kühlmi el im Primärzyklus, um die Kondensa onstemperatur im CO 2 -Zyklus unter dem kri schen Punkt zu halten, im Allgemeinen zwischen -5 C und -10 C) Das einzige Kühlmi el ist CO 2 Nega ve Auswirkungen auf die Umwelt (FKW-Emissionen) Hoher Stromverbrauch Höhere Kühlmi elmenge Höhere Kühlmi elkosten (wegen der FKWs) Natürliches Gas ohne ungüns ge Umweltauswirkungen (keine Schädigung der Ozonschicht) Energieersparnis Niedrigere Kühlmi elmenge Niedrigere Kühlmi elkosten BAULICHE MERKM ALE DES KÜHLSCHRANKS Betriebsdruck bis 73 bar Betriebsdruck bis 130 bar Der Hochdruckteil des Kreislaufs arbeitet unter dem kri schen Punkt Die CO 2 -Temperatur in der isothermen Prozessphase nach der Kompression der Flüssigkeit liegt unter dem kri schen Wert Der Hochdruckteil des Kreislaufs arbeitet über dem kri schen Punkt Die CO 2 -Temperatur am Ausgang des Gaskühlers beträgt über 31 C. Natürlich ist die Verdampfungstemperatur niedriger. Bei der Kühlung des komprimierten Gases erfolgt Kondensa on bei konstanter Temperatur Bei der Kühlung des komprimierten Gases erfolgt keine Kondensa on bei konstanter Temperatur An der Hochdruckseite kondensiert das CO 2 An der Hochdruckseite kühlt sich das CO 2 ab, kondensiert aber nicht, denn seine Temperatur bleibt über dem kri schen Punkt 3

4 4 OUR VALUES PRODUCTS has a wide range of products designed to detail to achieve op mum performance in every applica on. Our product range is designed to provide services to countless refrigera on applica ons and air condi oning. Our products are present in boats, offices, supermarkets, refrigerated trucks, etc... However, our technical department is ac ve and can make a customized design to customer requirements. Giving response, drawings, budgets, solu ons, alterna ves, etc. in 48 hours. MARKETING The marke ng of products is performed directly to the leading manufacturers in the world (OMS), as well as through business partners in different areas around the world. Our products are supplied in 32 countries. Tecnac has more than 300 customers, however, we con nue searching for new business partners, in order to con nue increasing our presence in the world.today, we can be proud because the biggest manufacturers and large groups of the world consume products, this is our warranty. SERVICE One of the pillars of is the service that we provide. We con nuously study solu ons to give great service to every customer. Our service adjust in each case to the demands of produc on for each customer, customizing our work. For all cases, we have a solu on. QUALITY is cer fied in both manufacturing and quality by Bureau Veritas: Our pressure equipment is marked in Module B + D according to the Pressure Equipment Direc ve 97/23 / EC and the design code AD-Merkbla er and UNE EN Cer fied welders and welding processes (manual and automa c) Materials approved by codes and rules listed above. Pressure test on 100% of our produc on. Non-destruc ve tes ng: radiographic, liquid penetrants,... Destruc ve tes ng: monthly fa gue tests (cycles) and breakage, in our own laboratory on batch manufacturing, analyzing both the materials and the produc on processes. All this qualifies us to apply the CE mark on all our products. Cer ficate ISO 9001: 2008, with a quality control of each component in all processes of the supply chain 4

5 5 UNSERE WERTE PRODUKTE Alle Erzeugnisse der breiten -Produktpale e sind bis ins kleinste Detail für op male Betriebseigenscha en entwickelt und konstruiert. In den Bereichen Kühlung und Klima sierung sind die Anwendungsbereiche unserer Produkte sehr vielfäl g: Sie kommen in Supermärkten und Büros zum Einsatz, aber auch auf Schiffen, in Kühllastwagen usw. Unsere technische Fachabteilung entwickelt jede erforderliche Komponente dieser Art nach Maß, ganz nach den Bedürfnissen des Kunden. Innerhalb von 48 Stunden erhalten Sie von uns einen Kostenvoranschlag mit Plänen, Lösungsvorschlägen, Alterna ven etc. VERMARKTUNG Tecnac vertreibt seine Erzeugnisse weltweit direkt an große Herstellerfirmen (Originalteilehersteller, OMS), aber auch über Handelspartner in verschiedenen Teilen der Welt. Wir beliefern bereits über 300 Kunden in insgesamt 32 Ländern und sind dennoch stets auf der Suche nach neuen Handelspartnern, um gemeinsam unsere weltweite Präsenz zu stärken. Heute dürfen wir nicht ohne Stolz feststellen, dass zahlreiche der weltweit größten Hersteller mit Tecnac-Erzeugnissen arbeiten - das ist unsere beste Bestätigung und Garantie. SERVICE Der Service ist einer der Grundpfeiler im Gesamtangebot von Tecnac: Wir sind ständig auf der Suche nach neuen Lösungen, um jedem einzelnen Kunden einen vorzüglichen Service zu bieten. Unsere Serviceleistungen passen sich an die Produk onsanforderungen des Kunden in jedem Einzelfall an die Betreuung ist immer ganz individuell und persönlich. Wir bieten Ihnen eine Lösung für jede Situa on. QUALITÄT Zer fikate von Bureau Veritas bescheinigen die Produktqualität und die Herstellungsverfahren von. Unsere Druckgeräte gehören gemäß der europäischen Richtlinie 97/23/EG zum Modul B+D und ihre baulichen Merkmale entsprechen den AD- Merkblä ern und der UNE-EN-Norm Zugelassene Schweißgeräte und Schweißprozesse (manuell und automa sch). Gemäß den oben genannten Vorschri en und Normen zugelassene Materialien. Drucktests mit allen Geräten und Komponenten unserer Herstellung. Zerstörungsfreie Prüfungen: Röntgenaufnahmen, Eindringen von Flüssigkeiten Zerstörende Prüfungen: In unserem eigenen Labor ausgeführte Tests auf Materialermüdung (zyklisch) und Bruch. Wir testen die monatlichen Chargen aus unserer Herstellung und analysieren sowohl Materialien als auch Produk onsabläufe. Die Summe dieser Verfahren und Prüfungen qualifiziert alle unsere Produkte für die EG-Kennzeichnung. Tecnac verfügt über das Zer fikat nach ISO 9001:2008 und prü die Qualität aller Bauteile in allen Schri en der Produk onske e gründlich. 5

6 6 6

7 7 7

8 CONTENT / INDEX 8 PAG. OIL SEPARATORS / ÖLABSCHEIDER COALESCENT OIL SEPARATORS KOALESZENTE ÖLABSCHEIDER SECTIONAL OIL SEPARATORS ABBAUBARE OLABSCHEIDER HIGH PRESSURE OIL SEPARATOR VESSEL TRENNBEHALTER HOCHCRUCKOL SUCTION ACCUMULATORS / ANSAUGAKKUMULATOR SUCTION ACCUMULATOR ANSAUGAKKUMULATOR LIQUID RECEIVERS / FLÜSSIGKEITSBEHÄLTER VERTICAL LIQUID RECEIVER WITH ROTALOCK VALVE (FROM 1L TO 15L) SENKRECHTER FLÜSSIGKEITSBEHÄLTER MIT ROTALOCKVENTIL (1L BIS 15L) VERTICAL LIQUID RECEIVER WITH COPPER CONNECTIONS (FROM 1L TO 15L) SENKRECHTER FLÜSSIGKEITSBEHÄLTER MIT KUPFERANSCHLÜSSEN (1L BIS 15L) LIQUID RECEIVERS FLÜSSIGKEITSBEHÄLTER LIQUID LEVEL ELECTRICAL DETECTOR ELEKTRISCHER FÜLLSTANDSDETEKTOR OIL RECEIVERS / ÖLBEHÄLTER OIL RECEIVERS ÖLBEHÄLTER ELECTRONICAL LEVEL REGULATOR / ELEKTRONISCHER FÜLLSTANDSREGLER ELECTRONICAL OIL LEVEL REGULATOR ELEKTRONISCHER FÜLLSTANDSREGLER

9 9 MUFFLERS / ENTLADUNGSDÄMPFER MUFFLERS ENTLADUNGSDÄMPFER VALVES / VENTILE ROTALOCK VALVES ROTALOCKVENTILE BALL VALVES KUGELVENTILE SAFETY VALVES SICHERHEITSVENTIL SERVICE VALVES BETRIEBSVENTILE SIGHTGLASS AND ROTALOCK ACCESORIES ROTALOCK- SICHTFENSTER UND ZUBEHÖRTEILE SUBCRITICAL UNTERKRITISCHE TRANSCRITICAL ÜBERKRITISCHE 9

10 10 COALESCENT OIL SEPARATORS KOALESZENTE ÖLABSCHEIDER SECTIONAL OIL SEPARATORS ABBAUBARE OLABSCHEIDER HIGH PRESSURE OIL SEPARATOR VESSEL TRENNBEHALTER HOCHCRUCKOL SUCTION ACCUMULATOR ANSAUGAKKUMULATOR LIQUID RECEIVERS FLÜSSIGKEITSBEHÄLTER LIQUID RECEIVERS FLÜSSIGKEITSBEHÄLTER 10

11 11 ELECTRONICAL LEVEL REGULATOR ELEKTRONISCHER FÜLLSTANDSREGLER LIQUID LEVEL ELECTRICAL GAUGE ELEKTRISCHER FÜLLSTANDSDETEKTOR OIL RECEIVER ÖLBEHÄLTER MUFFLERS ENTLADUNGSDÄMPFER ROTALOCK VALVES ROTALOCKVENTILE BALL VALVES KUGELVENTILE SAFETY AND SERVICE VALVES SICHERHEITSVENTIL / BETRIEBSVENTILE SIGHTGLASS AND ROTALOCK ACCESORIES ROTALOCK- SICHTFENSTER UND ZUBEHÖRTEILE 11

12 12 DIAGRAM R744 DIAGRAMM R744 Diagram R744 : Pressure (Bar) -Enthalpy (kj/kg) Diagramm R744 : Druck (Bar) -Enthalpie (kj/kg) 12

13 13 OIL SEPARATORS ÖLABSCHEIDER CO2 13

14 COALESCENT OIL SEPARATORS KOALESZENTE ÖLABSCHEIDER 14 To difference of other oil separators, the efficiency of the Tecnac Coalescent Oil Separators, it does not depend on the speed. Therefore, oil separator working (separating oil) to 99 % of efficiency when the load drop All oil separator include replacement coalescent filter. Im Gegensatz zu anderen Ölabscheidern hängt der Wirkungsgrad der koaleszenten -Abscheider nicht von der Geschwindigkeit ab. Daher arbeitet der -Abscheider auch bei verminderter Last noch mit einem Wirkungsgrad (der Ölabscheidung) von 99%. Alle Ölabscheider werden mit eingebautem koaleszentem Filter geliefert. Die Filter sind bei allen Modellen austauschbar. 45 bar -10/120ºC 10 bar -20/100ºC Kg Type Va (L) Vt (L) Dimensions Maße (mm) FOR CO 2 KW (Tªcond. -3,88ºC; supercalen. -12ºC; Subenfr. -17ºC) D H H1 H2 +40ºC -40ºC CAT. I SAC /8" a CAT. I SAC /8" a CAT. I SAC /8" a ,5 CAT. II SAC /8" b ,7 CAT. II SAC / b CAT.I II SAC / b ,5 373,4 CAT. III SAC / b ,9 CAT. III SAC / b ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN OPTIONAL / OPCIONAL: SPECIAL PAINTING FOR CO 2 SPEZIALFARBE FÜR CO µm (recomended / empfohlen) 14

15 COALESCENT OIL SEPARATORS WITH OIL RECEIVER KOALESZENTE ÖLABSCHEIDER MIT ÖLBEHÄLTER 15 Type(a) Type (b) SARC: VALVE INCLUDED 1 x 3/8 SAE / VENTILE 1 x 3/8 SAE SARC-NH 3 : ADAPTER INCLUDED 1 x 3/8 ODS / ADAPTER 1 x 3/8 ODS To difference of other oil separators, the efficiency of the Tecnac Coalescent Oil Separators, it does not depend on the speed. Therefore, oil separator working (separating oil) to 99 % of efficiency when the load drop. All oil separator include replacement coalescent filter. They have oil receiver included. Im Gegensatz zu anderen Ölabscheidern hängt der Wirkungsgrad der koaleszenten -Abscheider nicht von der Geschwindigkeit ab. Daher arbeitet der -Abscheider auch bei verminderter Last noch mit einem Wirkungsgrad (der Ölabscheidung) von 99%. Alle Ölabscheider werden mit eingebautem koaleszentem Filter geliefert.die Filter sind bei allen Modellen austauschbar. Mit eingebautem Ölbehälter. 45 bar -10/120ºC Vs Vr Vt Dimensions 10 bar -20/100ºC Kg Type (L) (L) (L) Maße (mm) KW (Tªcond.37.8ºC; supercalen. -12ºC; D H h H1 H2 +40ºC -40ºC CAT. I SARC /8" a CAT. I SARC /8" b ,5 17,8 CAT. I SARC /8" b ,7 27 CAT. II SARC /8" b ,3 CAT. II SARC / b CAT.I II SARC / b ,2 106 CAT. III SARC / b ,3 CAT. III SARC / b Vs: Volume Oil Separator / Volumen des Ölabscheiders Vr: Volume Oil Receiver / Volumen des Ölbehälters ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN OPTIONAL / OPCIONAL: SPECIAL PAINTING FOR CO 2 SPEZIALFARBE FÜR CO µm (recomended / empfohlen) 15

16 CO 2 COALESCENT OIL SEPARATORS FOR CO 2 (Transcritical) KOALESZENTE ÖLABSCHEIDER FÜR CO 2 (ÜBERKRITISCHE ) bar Designed for CO 2 transcritical systems, obtaining multiple advantages: an efficiency of separation superior to 98,5 %, improvement of the efficiency of the thermal transfer (it minimizes the quantity of oil in the evaporator), reduction of times of functioning of the compressor, for what obtain better performances that the rest of technologies of filtration and separation. Unsere für überkritische Systeme entworfenen CO2-Ölabscheider vereinen eine Reihe von Vorteilen: Ein hoher Wirkungsgrad der Abscheidung von 98,5 % verbessert auch den Wärmeübergang, denn er minimiert die Ölmenge im Verdampfer. Außerdem verkürzen sich die Laufzeiten des Kompressors, und verglichen mit anderen Filtrierund Trennverfahren erhält man bessere Leistungseigenschaften. 16

17 CO 2 COALESCENT OIL SEPARATORS FOR CO 2 (Transcritical) KOALESZENTE ÖLABSCHEIDER FÜR CO 2 (ÜBERKRITISCHE ) bar -10/120ºC 130 bar -10/80ºC Kg Vt (L) Dimensions Maße (mm) KW (Tªcond. 37.8ºC; supercalen. -12ºC; Subenfr. -17ºC) 90 bar -40/80ºC D H h H1 H2 +14ºC -40ºC CAT. II SAC 0-130bar 3/ CAT. II SAC 1-130bar 7/ CAT. II SAC 2-130bar 1 1/ CAT. II SAC 3-130bar 1 3/ CAT. III SAC 4-130bar 1 5/ CAT.I III SAC 5-130bar 2 1/ SPECIAL FILTER FOR TRANSCRITICAL SYSTEMS SPEZIAL FILTER FÜR ÜBERKRITISCHE CO 2 ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN MINIMUM LIQUID LEVEL ELECTRICAL GAUGE OPTIONAL FOR ALL THE LIQUID RECEIVERS ELEKTRISCHER FÜLLSTANDSDETEKTOR 130 bar -30 /120ºC LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 (Transcritical) ELEKTRISCHER FÜLLSTANDSDETEKTOR-CO2 (ÜBERKRITISCHE ) CODE MODEL MODELL Electrical Characteristics Elektrische Eigenschaften Relais Contact Type with solid Kontakt zum Signal am Feststoff Connection ANSCHL A INT V 2.5Amp Closed / Geschlossen SPST M20 x 1.5 ORDER / BESTELLUNG OPTIONAL LEVEL DETECTOR ELEKTRISCHER FÜLLSTANDSDETEKTOR- TO INCLUDE THE SAFETY VALVE ON MODELS : YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / LD EXAMPLE: SAC 2-130bar 1 1/8 / LD 17

18 SECTIONAL OIL SEPARATORS FOR CO 2 ABBAUBARE ÖLABSCHEIDER FÜR CO 2 (UNTERKRITISCHE ) 18 3/8 SAE 45 bar -10/100ºC Kg V (L) Dimensions Maße (mm) Capacity Kw at Evap. Temp.ºC R410A Va Vt Ø H d -40ºC +4ºC CAT. I SA-5-45bar 1 5/ CAT. I SA-5-45bar 2 1/ /8 SAE 45 bar -10/100ºC Kg V (L) Dimensions Maße (mm) Va Vt Ø H d CAT. I SA8-45bar 1 5/ CAT. I SA8-45bar 2 1/ CAT.I SA13-45bar 2 5/ CAT.II SA25-45bar 3 1/ Va : Oil Separator Volume / Volumen Ölabscheider Vt : Total Volume = Va + Oil Receiver Volume / Gesamtvolumen =Va + Volumen Ölbehälter SPARE FLANGE - FLOAT ERSATZTEIL FLANSCH - SCHWIMMER A O-RING INCLUDED FLANSCHDICHTUNG ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 18

19 HIGH PRESSURE OIL SEPARATOR VESSEL FOR CO 2 (Subcritical) BEHÄLTER HOCHDRUCKÖLABSCHEIDER FÜR CO 2 (Unterkritisch) 19 Rotalock Valve Included 1 X 3/8 SAE Dimensions 45bar -10/100ºC (Unterkritisch) Kg V (L) Maße (mm) Va Vt Vv1 Vv2 Ø Hout Hr Hv1 Hv2 H CAT. II SAV-3,5/45 7/8" ,9 2, CAT. II SAV-3,5/45 1 1/8" ,9 2, CAT. II SAV-3,5/45 1 3/8" ,9 2, CAT. II SAV-9,5/45 1 3/8" ,9 5, CAT. II SAV-9,5/45 1 5/8" ,9 5, CAT. II SAV-9,5/45 2 1/8" ,9 5, CAT. III SAV-20/45 2 1/8" , CAT. III SAV-20/45 2 5/8" , CAT. III SAV-20/45 3 1/8" , All models include rotalock valve 1 x 3/8 SAE in oil outlet connections Alle Modelle enthalten Rotalockventil 1 x 3/8 SAE am Anschluss des Ölausgangs. OPTIONAL / OPCIONAL: SPECIAL PAINTING FOR CO 2 SPEZIALFARBE FÜR CO µm (recomended / empfohlen) ELECTRONICAL LEVEL REGULATOR COMPATIBLE WITH SAV-45bar ELEKTRONISCHER FÜLLSTANDSREGLER FÜR SAV -45-CO 2 ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 19

20 20 20

21 21 SUCTION ACCUMULATORS ANSAUGAKKUMULATOR CO2 21

22 SUCTION ACCUMULATOR FOR CO 2 (Subcritical) ANSAUGAKKUMULATOR FÜR CO 2 (UNTERKRITISCHE ) 22 22

23 SUCTION ACCUMULATOR FOR CO 2 (Subcritical) ANSAUGAKKUMULATOR FÜR CO 2 (UNTERKRITISCHE ) 23 DAL-CO 2 BT-CO 2 BTR-CO 2 30bar -10/80ºC Model Modell Code Vol (L) Connect, Anschl. Ø mm L (mm) H ( mm) E (mm) Screw Schraube CAT. I DAL-018A - CO /8" M10 DAL-019A - CO /8" M10 DAL-021A - CO ,1 1 3/8" M10 CAT.II DAL-022A - CO /8" M10 DAL-023B - CO /8" M10 30 bar -40/100ºC Model Modell Code Vol (L) Connect, Anschl. Ø (mm) B (mm) T (mm) H (mm) E (mm) CAT.II BT-180A CO /8" 219, CAT. III BT-360A CO /8" BT-360B CO /8" 323, bar -40/100ºC Model Modell Code Vol (L) Connect, Anschl. Ø (mm) B (mm) T (mm) H (mm) E (mm) BTR-180A CO /8" 219, CAT. III BTR-360A CO /8" 323, ORDER / BESTELLUNG OPTIONAL SAFETY VALVE SICHERHEITSVENTIL TO INCLUDE THE SAFETY VALVE ON MODELS BT YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / V.SG EXAMPLE: BT-180-A-CO 2 / V.SG OPTIONAL / OPCIONAL: SPECIAL PAINTING FOR CO 2 ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN SPEZIALFARBE FÜR CO µm (recomended / empfohlen) 23

24 SUCTION ACCUMULATOR FOR CO 2 (Transcritical) ANSAUGAKKUMULATOR FÜR CO 2 (ÜBERKRITISCHE) bar -10/80ºC 90bar -40/80ºC Model Modell Code Vol (L) Connect, Anschl. Ø (mm) L (mm) H (mm) E (mm) CAT. I DAL-011A bar TR ,5 5/ DAL-012A 130bar - TR / DAL-016A 130bar - TR / CAT.II DAL-017A - 130bar - TR / DAL-019A 130bar - TR / DAL-021B 130bar - TR / CAT. III DAL-022B 130bar - TR / ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 24

25 25 LIQUID RECEIVERS FLÜSSIGKEITSBEHÄLTER CO2 25

26 LIQUID RECEIVERS FROM 1L TO 15L FLÜSSIGKEITSBEHÄLTER -1L BIS 15L 26 ORDER / BESTELLUNG TO INCLUDE THE SAFETY VALVE AND/OR OUT VALVE YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / V.OUT / V.SG EXAMPLE: DVR-700-M-45 / V.OUT / V.SG 45 bar -10/80ºC 20bar -40/80ºC VERTICAL LIQUID RECEIVER WITH ROTALOCK VALVE SENKRECHTER FLÜSSIGKEITSBEHÄLTER MIT ROTALOCKVENTIL Model Modell Code Vol (L) Ø (mm) L (mm) IN inch OUT inch SAFETY VALVE SICHERHEITSVENTIL CAT- 0 DVR-150-M/42bar 0,7020 1,2L /4 ODS 3/4 X 1/4 ODS - DVR-200-M/45bar 0,7021 2L /8 ODS 3/4 X 3/8 ODS - CAT. I DVR-300-M/45bar 0,7022 3L ½ ODS 1 X 1/2 ODS DVR-500-M/45bar 0,7023 5L ½ ODS 1 X 1/2 ODS DVR-700-M/45bar 0,7024 7L ½ ODS 1 X 1/2 ODS 1/4 NPT CAT. II DVR-1100-M/45bar 0, L /8 ODS 1 X 1/2 ODS DVR-1500-M/45bar 0, L /8 ODS 1 1/4" X 7/8 ODS ORDER / BESTELLUNG TO INCLUDE THE SAFETY VALVE YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / V.SG EXAMPLE: DVC-700-A-45/ V.SG 45 bar -10/80ºC 20bar -40/80ºC VERTICAL LIQUID RECEIVER WITH COPPER CONNECTIONS SENKRECHTER FLÜSSIGKEITSBEHÄLTER MIT KUPFERANSCHLÜSSEN Model Modell Code Vol (L) Ø (mm) L (mm) IN inch OUT inch SAFETY VALVE SICHERHEITSVENTIL CAT- 0 DVC-150-A/42bar 0,6016 1,2L /8 ODS 3/8 ODS - DVC-200-A/45bar 0,6013 2L /8 ODS 3/8 ODS - CAT. I DVC-300-A/45bar 0,6017 3L /8 ODS 3/8 ODS DVC-500-A/45bar 0,6012 5L ½ ODS ½ ODS DVC-700-A/45bar 0,6009 7L ½ ODS ½ ODS 1/4 NPT CAT. II DVC-1100-A/45bar 0,601 11L ¾ ODS ¾ ODS DVC-1500-A/45bar 0, L ¾ ODS ¾ ODS 26

27 27 ORDER / BESTELLUNG TO INCLUDE THE SAFETY VALVE YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / V.SG EXAMPLE: DVY-11-45/ V.SG 45 bar -10/80ºC VERTICAL LIQUID RECEIVER WITH COPPER CONNECTIONS SENKRECHTER FLÜSSIGKEITSBEHÄLTER MIT KUPFERANSCHLÜSSEN Model Modell Code Vol (L) Ø (mm) L (mm) IN inch OUT inch SAFETY VALVE SICHERHEITSVENTIL CAT- 0 DVY-0.75/42bar ,75L ½ ODS ½ ODS DVY-1.5/42bar L ½ ODS ½ ODS CAT. I CAT. II DVY-2/45bar L /8 ODS 5/8 ODS DVY-3/45bar L /8 ODS 5/8 ODS DVY-5/45bar L /8 ODS 5/8 ODS DVY-7/45bar L /8 ODS 5/8 ODS DVY-11/45bar L /8 ODS 7/8 ODS DVY15/45bar L /8 ODS 7/8 ODS 1/4 NPT 27

28 CO 2 VERTICAL RECEIVERS SENKRECHTER BEHÄLTER FÜR CO 2 28 Sicherheits Detektor Höchststand Detektor Höchststand ORDER / BESTELLUNG: TO INCLUDE THE ACCESORIES, YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTE- LLUNG AN: MODEL / AX / MLD / D (Nº) / V.SG EXAMPLE: RV-60-CO 2 / AX / MLD / D (2) /V.SG SAFETY VALVE / SICHERHEITSVENTIL LEVEL DETECTOR (UNITS ) / LEKTRISCHER FÜLLSTANDSDETEKTOR 5 1 MÁX. LEVEL DETECTOR 2 3 / LEKTRISCHER FÜLLSTANDSDETEKTOR AUXILIAR CONNECTION / HIFS-ANSCHLUSS 28

29 CO 2 VERTICAL RECEIVERS SENKRECHTER BEHÄLTER FÜR CO bar -10/100ºC (Subcritical / UNTERKRITISCHE ) OPTIONAL Safety Model Modell Code V (L) Ø mm L mm IN (1) EINGANGS IN (2) EINGANGS OUT AUSGANG Sightglass Anzeigen Connection Sicherheits Min. Level Detector / Detektor Mindeststand Auxiliar Connec./ Hilfsanschluss Máx. Level Detector / Detektor Höchststand Level Column RV10-CO /2" 159 ODS RV15-CO RV30-CO RV45-CO RV60-CO RV90-CO 2 (273) /8" ODS 7/8" ODS 7/8" ODS 2 1/2" NPT 7/8" ODS RV90-CO 2 (355) RV120-CO RV120 CO 2 (355) /2" NPT 1-1/8" ODS 1/2" NPT Inox 21mm RV150-CO RV180-CO /2" NPT 1-3/8" ODS RV250-CO /8" ODS 1-1/8" ODS 1-1/8" ODS RV300-CO /8" ODS RV300 CO 2 (508) ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 COMPATIBLE MESSFÜHLER FLÜSSIGKEITSSTAND FÜR CO 2 KOMPATIBEL 29

30 CO 2 HORIZONTAL RECEIVERS FLÜSSIGKEITSBEHÄLTER FÜR CO2 30 RH-CO 2 RH-INC-CO 2 ORDER / BESTELLUNG TO INCLUDE THE ACCESORIES, YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / AX / MLD / D (Nº) / V.SG EXAMPLE: RH-150-CO 2 / AX / MLD / D (2) /V.SG SAFETY VALVE / SICHERHEITSVENTIL LEVEL DETECTOR (UNITS ) / LEKTRISCHER FÜLLSTANDSDETEKTOR MÁX. LEVEL DETECTOR 3 / LEKTRISCHER FÜLLSTANDSDETEKTOR AUXILIAR CONNECTION / HIFS-ANSCHLUSS 30

31 CO 2 HORIZONTAL RECEIVERS FLÜSSIGKEITSBEHÄLTER FÜR CO bar -10/100ºC (Subcritical / UNTERKRITISCHE ) OPTIONAL Model Modelo Code Código V (L) IN (1) EINGANGS IN (2) EINGANGS OUT AUSGANG Ø (mm) L (mm) Sightglasses Anzeigen Safety Connection Sicherheits Min level detector / Detektor Mindeststand Auxiliar connect./ Hilfsanschluss RH10-CO /2" RH15-CO ODS RH30-CO RH45-CO RH60-CO /8" 1143 ODS 273 RH90-CO 2 (273) /8" 7/8" ODS ODS RH90-CO 2 (355) RH120-CO 2 (323) RH120-CO 2 (355) RH150-CO RH180-CO /8" 1-1/8" 1-1/8" RH250-CO ODS ODS ODS RH300-CO /2" NPT 7/8" ODS 3 1/2" NPT 1/2" NPT 1-1/8" ODS 1-3/8" ODS 1-5/8" ODS Max. level detector Detektor Höchststand 1/2" NPT 45bar -10/100ºC (Subcritical / UNTERKRITISCHE ) OPTIONAL Model / Modell Code V (L) IN (1) EINGANGS IN (2) EINGANGS OUT AUSGANG Ø L Sightglasses Anzeigen Safety Connection Sicherheits Min level detector / Auxiliar connec./ Detektor Hilfs-anschluss Mindeststand Max. level detector Detektor Höchststand RH10-INC-CO /2" RH15-INC-CO ODS RH30-INC-CO RH45-INC-CO /8" RH60-INC-CO ODS 7/8" 7/8" 273 RH90-INC-CO 2 (273) ODS ODS RH90-INC-CO 2 (355) RH120-INC-CO 2 (323) RH120-INC-CO 2 (355) /2" NPT 1/2" NPT 7/8" ODS 1-1/8" ODS 1/2" NPT RH150-INC-CO RH180-INC-CO /8" 1-1/8" 1-1/8" RH250-INC-CO ODS ODS ODS 2100 RH300-INC-CO /2" NPT 1-3/8" ODS 1-5/8" ODS ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 COMPATIBLE MESSFÜHLER FLÜSSIGKEITSSTAND FÜR CO 2 KOMPATIBEL 31

32 CO 2 VERTICAL RECEIVERS SENKRECHTER BEHÄLTER FÜR CO 2 32 Sicherheits Detektor Höchststand Detektor Höchststand ORDER / BESTELLUNG TO INCLUDE THE ACCESORIES, YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / AX / MLD / D (Nº) / V.SG EXAMPLE: RV-60-60bar-CO 2 / AX / MLD / D (2) /V.SG RV bar-CO 2 / AX / MLD / D (2) /V.SG SAFETY VALVE / SICHERHEITSVENTIL LEVEL DETECTOR (UNITS ) / LEKTRISCHER FÜLLSTANDSDETEKTOR MÁX. LEVEL DETECTOR 3 / LEKTRISCHER FÜLLSTANDSDETEK- AUXILIAR CONNECTION / HIFS-ANSCHLUSS ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 32

33 CO 2 VERTICAL RECEIVERS SENKRECHTER BEHÄLTER FÜR CO 2 33 Model Modell Code 60 bar -10/80ºC (Transcritical / ÜBERKRITISCHE ) OPTIONAL V (L) Ø mm L mm IN (1) EIN- GANGS IN (2) OUT AUS- EINGANGS GANG Sightglass Anzeigen Safety Connection Sicherheits Min. Level Detector / Detektor Mindeststand Conex. Auxiliar- Hilfsanschluss Máx. Level Detector / Detektor Höchststand RV10-60bar-TR /2" RV15-60bar-TR ODS - - RV30-60bar-TR RV45-60bar-TR RV60-60bar-TR RV90-60bar-TR (273) RV90-60bar-TR (355) RV120-60bar-TR /8" ODS 7/8" ODS 7/8" ODS 1" NPT 1/2" NPT 1/2" NPT RV150-60bar-TR /8" RV180-60bar-TR /8" 1-1/8" 1-1/8" ODS 406 RV250-60bar-TR ODS ODS ODS 1-5/8" RV300-60bar-TR ODS 7/8" ODS 1-1/8" ODS 1/2" NPT 130 bar -10/80ºC (Transcritical / ÜBERKRITISCHE ) OPTIONAL Exchanger WÄRMETAUSCHER 5/8" Model Modell Code V (L) Ø mm L mm IN (1) EINGANGS IN (2) EINGANGS OUT AUS- GANG Sightglass Anzeigen Safety Connection Sicherheits Min. Level Detector / Detektor Mindeststand Auxiliar/ Connec. Hilfsanschluss Máx. Level Detector / Detektor Höchststand Exchanger WÄRMETAUSCHER RV10-130bar-TR /2" RV15-130bar-TR ODS - - RV30-130bar-TR RV45-130bar-TR RV60-130bar-TR RV90-130bar-TR (273) RV90-130bar-TR (355) RV bar-TR /8" ODS 7/8" ODS 7/8" ODS 1" NPT 1/2" NPT 1/2" NPT 7/8" ODS RV bar-TR /8" RV bar-TR ODS 1-1/8" 1-1/8" 1-1/8" 406 RV bar-TR ODS ODS ODS 1-5/8" RV bar-TR ODS 1-1/8" ODS 1/2" NPT 5/8" WORKING CONDITIONS FOR TRANSCRÍTICAL BETRIEBSBEDINGUNGEN FÜR ÜBERKRITISCHE OPTION 1 OPTION 2 OPTION 3 OPTION 4 OPTION 5 60 bar -10/80ºC 45 bar -10/120ºC 80 bar -10/80ºC 90 bar -10/120ºC 60 bar -40/80ºC 120 bar -10/80ºC 90 bar -40/80ºC 130 bar -10/80ºC 90 bar -40/80ºC LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 COMPATIBLE MESSFÜHLER FLÜSSIGKEITSSTAND FÜR CO 2 KOMPATIBEL 33

34 MINIMUM LIQUID LEVEL ELECTRICAL GAUGE OPTIONAL FOR ALL THE LIQUID RECEIVERS ELEKTRISCHE FÜLLSTANDANZEIGE OPTIONAL FÜR ALLE FLÜSSIGKEITSBEHÄLTER 34 The optical level switch has been designed for use in level monitoring applications for the control of low viscosity liquids. It comprises an optical sensor and an output switch. It is realized in two parts to let it possible to replace the electronics without the needing of emptying or depressurizing the plant. The sensor is suitable as mínimum or máximum alarm. No need for calibrations on the field. Unit conform to directives: CE and CEI EN :2006 Der optische Füllstandsschalter ist für Anwendungen entwickelt, die Flüssigkeiten niedriger Viskosität überwachen. Er umfasst einen optischen Sensor und einen Ausgangsschalter. Dieses Bauteil ist in zwei getrennten Abschnitten ausgeführt, damit Sie zum Austausch der Elektronik Ihre Anlage nicht entleeren oder druckfrei machen müssen. Der Sensor arbeitet mit Alarm bei Minimums- oder Maximumskriterium. Keinerlei Feldkalibrierung ist erforderlich. Dieses Bauteil erfüllt die Richtlinien EG und CEI EN :2006. SUPPLY VOLTAGE / Versorgungsspannung 230 ELECTRICAL CONNECTION / Stromanschluss EN A connector (EX DIN size A) / Verbinder EN A (EX DIN 43650, Größe A) OUTPUT SIGNAL / Ausgangssignal SUPPLY CURRENT / Versorgungsstrom OUTPUT MAX. CURRENT / Maximaler Ausgangsstrom Solid state output Normally Open or Normally Close in air / Halbleiter-Ausgang in Lu normalerweise offen oder norm. geschlossen 20mA max during normal opera on / Maximal 20 ma im Normalbetrieb Up to 100 ma / Bis 100 ma HOUSING MATERIAL / Gehäusematerial Nickel plated Steel / Vernickelter Stahl ENCLOSURE PROTECTION CLASS / Schutzart des Gehäuses P 65 AMBIENT TEMPERATURE / Umgebungstemperatur -40ºC / +125ºC MAXIMUM PRESSURE / Maximaldruck 46 bar TORQUE TIGHTEN / Anzugsdrehmoment 50 Nm for adapter installla on on the system / 50 Nm an Adapteranschlüssen. 45 bar -40 /125ºC LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 / ELEKTRISCHE FÜLLSTANDANZEIGE FÜR CO2 CODE MODEL Electrical Characteristics Contact Type with solid Connec on MODELL Elektrische Eigenschaften Relais Kontakt zum Signal am Feststoff A LC-XT7 230VAC@50Hz Open / Abierto ANSCHL 1/2 NPT 34

35 MINIMUM LIQUID LEVEL ELECTRICAL GAUGE OPTIONAL FOR PRIMARY OIL SEPARATOR ELEKTRISCHER FÜLLSTANDSDETEKTOR FÜR PRIMÄRÖLABSCHEIDER FUR SCHRA UBENKOMPRESSOR 35 The optical level switch has been designed for use in level monitoring applications for the control of low viscosity liquids. It comprises an optical sensor and an output switch. It is realized in two parts to let it possible to replace the electronics without the needing of emptying or depressurizing the plant. The sensor is suitable as mínimum or máximum alarm. No need for calibrations on the field. Unit conform to directives: CE and CEI EN :2006 Der optische Füllstandsschalter ist für Anwendungen entwickelt, die Flüssigkeiten niedriger Viskosität überwachen. Er umfasst einen optischen Sensor und einen Ausgangsschalter. Dieses Bauteil ist in zwei getrennten Abschnitten ausgeführt, damit Sie zum Austausch der Elektronik Ihre Anlage nicht entleeren oder druckfrei machen müssen. Der Sensor arbeitet mit Alarm bei Minimums- oder Maximumskriterium. Keinerlei Feldkalibrierung ist erforderlich. Dieses Bauteil erfüllt die Richtlinien EG und CEI EN :2006. SUPPLY VOLTAGE / Versorgungsspannung 230 ELECTRICAL CONNECTION / Stromanschluss EN A connector (EX DIN size A) OUTPUT SIGNAL / Ausgangssignal Solid state output Normally Open or Normally Close in air / Halbleiter-Ausgang in Luft SUPPLY CURRENT / Versorgungsstrom 20mA max during normal operation / Maximal 20 ma im Normalbetrieb OUTPUT MAX. CURRENT / Maximaler Ausgangsstrom Up to 100 ma / Bis 100 ma HOUSING MATERIAL / Gehäusematerial Nickel plated Steel / Vernickelter Stahl ENCLOSURE PROTECTION CLASS / Schutzart des Gehäuses IP 65 AMBIENT TEMPERATURE / Umgebungstemperatur -40 ºC / +125 ºC MAXIMUM PRESSURE / Maximaldruck 46 bar TORQUE TIGHTEN / Anzugsdrehmoment 50 Nm for adapter installlation on the system / 50 Nm an Adapteranschlüssen. 45 bar -40 /125ºC LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 / ELEKTRISCHER FÜLLSTANDSDETEKTOR FÜR CO 2 MODEL Electrical Characteristics Contact Type with solid CODE MODELL Elektrische Spannung Kontakt zum Signal am Feststoff A RLK02 230VAC@50Hz Open Connec on Rotalock 1 3/4 35

36 MINIMUM LIQUID LEVEL ELECTRICAL GAUGE OPTIONAL FOR ALL THE LIQUID RECEIVERS ELEKTRISCHE FÜLLSTANDANZEIGE OPTIONAL FÜR ALLE FLÜSSIGKEITSBEHÄLTER 36 The optical level switch has been designed for use in level monitoring applications for the control of low viscosity liquids. It comprises an optical sensor and an output switch. It is realized in two parts to let it possible to replace the electronics without the needing of emptying or depressurizing the plant. The sensor is suitable as mínimum or máximum alarm. No need for calibrations on the field. Unit conform to directives: CE and CEI EN :2006 Der optische Füllstandsschalter ist für Anwendungen entwickelt, die Flüssigkeiten niedriger Viskosität überwachen. Er umfasst einen optischen Sensor und einen Ausgangsschalter. Dieses Bauteil ist in zwei getrennten Abschnitten ausgeführt, damit Sie zum Austausch der Elektronik Ihre Anlage nicht entleeren oder druckfrei machen müssen. Der Sensor arbeitet mit Alarm bei Minimums- oder Maximumskriterium. Keinerlei Feldkalibrierung ist erforderlich. Dieses Bauteil erfüllt die Richtlinien EG und CEI EN :2006. SUPPLY VOLTAGE / Versorgungsspannung 230 ELECTRICAL CONNECTION / Stromanschluss EN A connector (EX DIN size A) / Verbinder EN A (EX DIN 43650, Größe A) OUTPUT SIGNAL / Ausgangssignal SUPPLY CURRENT / Versorgungsstrom OUTPUT MAX. CURRENT / Maximaler Ausgangsstrom HOUSING MATERIAL / Gehäusematerial ENCLOSURE PROTECTION CLASS / Schutzart des Gehäuses IP 65 AMBIENT TEMPERATURE / Umgebungstemperatur MAXIMUM PRESSURE / Maximaldruck TORQUE TIGHTEN / Anzugsdrehmoment Solid state output Normally Open or Normally Close in air / Halbleiter-Ausgang in Lu normalerweise offen oder norm. geschlossen 20mA max during normal opera on / Maximal 20 ma im Normalbetrieb Up to 100 ma / Bis 100 ma Nickel plated Steel / Vernickelter Stahl -40ºC / +125ºC 120 bar 50 Nm for adapter installla on on the system / 50 Nm an Adapteranschlüssen. 120 bar -40 /125ºC LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 (Transcritical) MESSFÜHLER FLÜSSIGKEITSSTAND FÜR CO 2 (ÜBERKRITISCHE ) MODEL Electrical Characteristics Contact Type with solid CODE MODELL Elektrische Spannung Kontakt zum Signal am Feststoff A LC-XP 230VAC@50Hz Open Connection ANSCHL 1/2 NPT 36

37 MINIMUM LIQUID LEVEL ELECTRICAL GAUGE OPTIONAL FOR ALL THE LIQUID RECEIVERS ELEKTRISCHE FÜLLSTANDANZEIGE OPTIONAL FÜR ALLE FLÜSSIGKEITSBEHÄLTER bar -30 /120ºC LIQUID LEVEL ELECTRICAL GAUGE FOR CO 2 (Transcritical) / ELEKTRISCHE FÜLLSTANDANZEIGE FÜR CO2 (ÜBERKRITISCHE ) CODE MODEL Electrical Characteristics Contact Type with solid MODELL Elektrische Eigenschaften Relais Kontakt zum Signal am Feststoff A INT V 2.5Amp Closed SPST Connection ANSCHL M20 x

38 38 38

39 39 OIL RECEIVERS ÖLBEHÄLTER CO2 39

40 OIL RECEIVERS ÖLBEHÄLTER 40 The oil receiver should be mounted above the oil level regulators for the supply of oil through gravity. Due to the high pressure, the oil could return to the container. Over a period of time, too much pressure could affect unfavourably the oil level regulator. For protection, a ventilation line installed above the oil container, diminishing the pressure to the line of the accumulator. This line allows the pressure in the oil container to be approximately the same as in the suction line and the crankcase The oil is supplied through a 3/8 " SAE. Connection Assembly pressure valve VRH for correct functioning Der Ölbehälter muss über den Ölstandsreglern für die Zuleitung durch Gravität eingebaut werden. Es kann sein, dass aufgrund des hohen Drucks, das Öl des Ölabscheiders zum Behälter zurückgelangt. Hoher Druck über einen längeren Zeitraum kann den Ölstandsregler schädigen. Zum Schutz wird eine Belüftungslinie über dem Ölbehälter installiert, durch die der Niedrigdruck zurück zur Akkumulatorlinie geleitet wird. Diese Linie ermöglicht es, dass der Druck im Ölbehälter etwa wie der in der Ansauglinie und dem Kompressorgehäuse ist. Die Ölversorgung erfolgt über einen Anschluss 3/8 " SAE. Zur einwandfreien Funktion wird der Einbau eines VRHA-Ventils empfohlen. CAT. II 45bar -10/100ºC (Subcritical / UNTERKRITISCHE ) MODEL CODE Vol VALVE IN / OUT MODELL ( L ) VENTIL EIN/AUS All the models includes two sight glasses, an adaptor of 3/8 SAE and two rotalock valves 1 x 3/8 SAE. Alle Modelle umfassen zwei Anzeigen, einen Adapter 3/8 SAE und zwei Rotalockventile 1 x 3/8 SAE. Oil receiver pressure valve no included (order code A ) Druckventil für den Ölbehälter ist nicht inbegriffen (fragen Sie nach dem Bauteilcode A ) DIMENSIONS - MAßE (mm) Ø A B C L H RHA /8 SAE RHA /8 SAE RHA /8 SAE RHA /8 SAE RHA /8 SAE bar -40/105ºC MODEL MODELL CODE OIL RECEIVER PRESSURE VALVE VENTIL-DRUCK Connection ANSCHL Pressure Diferential Differential des Drucks (bar) Kv (m 3 /h) VRHA A /8 SAE H x M VALID FOR ALL THE REFRIGERANTS HFC: R22, R134a, R404A, R507,..ETC FÜR ALLE KÜHLMITTEL GEEIGNET HFC: R22, R134a, R404A, R507,..ETC ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 40

41 OIL RECEIVERS FOR CO 2 ÖLBEHÄLTER FÜR CO 2 41 CAT. II CAT. III CAT. III 60bar -10/80ºC (Transcritical / ÜBERKRITISCHE ) DIMENSIONS - MAßE (mm) MODEL CODE Vol IN / OUT MODELL ( L ) EIN/AUS Ø A B C L H RHA-8-60bar /8 ODS RHA-12-60bar /8 ODS RHA-16-60bar /8 ODS RHA-20-60bar /8 ODS RHA-30-60bar /8 ODS bar -10/80ºC (Transcritical / ÜBERKRITISCHE ) DIMENSIONS - MAßE (mm) MODEL CODE Vol IN / OUT MODELL ( L ) EIN/AUS Ø A B C L H RHA-8-130bar /8 ODS RHA bar /8 ODS RHA bar /8 ODS RHA bar /8 ODS CAT. IV RHA bar /8 ODS All the models includes two sight glasses Alle Modelle umfassen zwei Anzeigen Oil receiver pressure valve no included (order code A ) Druckventil für den Ölbehälter ist nicht inbegriffen (fragen Sie nach dem Bauteilcode A ) 130 bar -10/80ºC MODEL MODELL OIL RECEIVER PRESSURE VALVE / VENTIL-DRUCK CODE Connection ANSCHL Pressure Diferential Differential des Drucks (bar) Kv (m 3 /h) VRHA A /8 SAE H x M ORDER / BESTELLUNG OPTIONAL SAFETY VALVE SICHERHEITSVENTIL TO INCLUDE THE SAFETY VALVE ON MODELS YOU MUST INDICATE IN YOUR ORDER: FALLS SIE IHRE MODELLE MIT SICHERHEITSVENTIL WÜNSCHEN, GEBEN SIE DAS BITTE IN DER BESTELLUNG AN: MODEL / V.SG EXAMPLE: RHA-8-130bar / V.SG ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 41

42 42 42

43 43 ELECTRONICAL LEVEL REGULATOR ELEKTRONISCHER FÜLLSTANDSREGLER CO2 43

44 ELECTRONICAL OIL LEVEL REGULATORS ELEKTRONISCHER FÜLLSTANDSREGLER 44 L1 Designed to control the oil level in the compressor crankcase in order to avoid the compressor to run without oil and so improve its life me. TK3 monitors the oil level with the embedded electro-op c sensor and comprises a solenoid valve for oil filling and a relay output contact to give an alarm. - Extremely compact dimensions - Le /Right moun ng possibility with the same TK3 - Reduc on of the number of junc ons in the circuit with less possibility of having leakages. - Usage of less components - Simplified Installa on (cost savings in terms of installa on me) MAIN FEATURES High reliability ensured by absence of mechanical moving parts. Sight glass and electronic LEDs can be checked on the same side where is more comfortable to do inspec ons. Well consolidated steel with fused glass technology with absence of seals ensures no leakage and good chemical compa bility. Direct sight glass replacement (3/4/6 holes flange connec on) Easy maintenance of the coil of the valve and of the Electro-Op c sensor that can be easily replaced without emptying or depressurizing the plant. 230 VAC /2A alarm relay output suitable for direct connec on in the security chain of the system Adapters suitable for various types of compressors Dieses Instrument misst den Ölstand im Kurbelgehäuse des Kompressormotors. So vermeiden Sie den Kompressorbetrieb ohne Öl und sorgen für eine lange Lebensdauer. Der TK3 überwacht den Ölstand mit einem elektronisch-optischen Sensor und umfasst ein Magnetventil zum Einfüllen von Öl sowie einen Ausgangskontakt, der Alarmmeldungen ausgibt. - Sehr kompakte Abmessungen. - Montage des TK3 links oder rechts möglich. - Dank einer geringeren Anzahl von Verbindungen gibt es im Kreislauf weniger für Leckagen anfällige Stellen. - Einsatz von weniger Bauteilen. - Vereinfachte Installation (kostengünstig durch verkürzte Installationszeit). Hauptmerkmale * Keine beweglichen mechanischen Teile: daher höchste Zuverlässigkeit. * Sichtanzeige und elektronische LEDs lassen sich an der gleichen Seite prüfen, womit Inspektionen bequemer möglich sind. * Verstärkter Stahl mit Flüssigkeitskristall-Technologie, ohne Dichtungen, ohne Leckagen und hervorragend mit Chemikalien kompatibel. * Direktersatz der Sichtanzeige (3/4/6, Anschluss am verstärkten Lochrand). * Einfache Wartung von Ventil und elektro-optischem Sensor; sein Austausch ist ohne Entleerung der Anlage und ohne Ablassen des Drucks leicht möglich. * Alarmausgang mit 230 VAC/2 A, geeignet für den Direktanschluss an die Sicherheitsvorrichtung Ihres Systems. * Adapter für unterschiedliche Kompressortypen SUPPLY VOLTAGE / Versorgungsspannung 230 VAC ± 10% ELECTRICAL CONNECTION / Stromanschluss 9,4mm Industry Standard Connectors / EN Connector or spare wires / Standard- OUTPUT SIGNAL / Ausgangssignal Contact free relay output NO and NC / Kontak reie Relais, NO und NC RELAY OUTPUTS / Relaisausgänge Up to / Bis 230 VAC bei 2 A HOUSING MATERIAL / Gehäusematerial Nickel plated Steel / Vernickelter Stahl ENCLOSURE PROTECTION CLASS / Schutzart des Gehäuses IP 65 MEDIA TEMPERATURE / Temperatur des Mediums -40ºC / +85ºC AMBIENT TEMPERATURE / Umgebungstemperatur -40ºC / +60ºC OIL RETURN LINE / Ölrücklaufleitung 7/16-20 UNEF male / Außengewinde CABLE TYPE / Kabel PVC cable CEI Working temp / PVC-Kabel CEI 20-22, Betriebstemperatur von -20 ºC bis +70 ºC Code Max. Working MOPD TK3 46bar-230V A TK3 46bar-24V A TK3 80bar-230V A TK3 80bar-24V A TK3 120bar-230V A TK3 120bar-24V A bar 26 bar 80 bar 60 bar 120 bar 100 bar VALID FOR SUBCRITICAL / UNTERKRITISCH VALID FOR TRANSCRITICAL / UBERKRITISCH: VALID FOR TRANSCRITICAL / UBERKRITISCH: MOPD: Maximum Opera ng Pressure Differen al / Differential des Drucks VERSIÓN 24V CONSULT / 24V KONTAKT VALID FOR ALL THE REFRIGERANTS HFC, CO 2,... FÜR ALLE KÜHÑMITTEL GEEIGNET HFC, CO 2,... 44

45 ACCESORIES / ZUBEHÖR : ADAPTERS FOR ELECTRONICAL OIL LEVEL REGULATORS ADAPTER FÜR ÖLNIVEAU-REGLER-INSTALLATION 45 Model Modell Code 0 No Adapter (Direct moun ng) 1 TK3 ADAPTER 1 1/8" 18 UNEF A TK3 ADAPTER 3/4" NPT A TK3 ADAPTER 3/4/6 HOLES FLANGE (also as a spacer 50mm) A Compressor Family /Model TK3 selection Arctic Circle G2; G4; G6 0 or 3 4G; 4H; 4J; 4NC; 4NHC-20K; 4PC; 4PHC-15K; 4THC-12K; 4VC; 4VHC-10K; 4VNC; 4Z; 6F; 6G; 6H; 6J 8FC; 8GC; S4; S6; 0 or 3 Bitzer 2CHC-4K; 2DC; 2DHC-3K; 2EC; 2EHC-3K; 2FC; 2FHC-3K; 2GC; 2GHC-2K; 2HC; 2HHC-2K; 2JC; 2JHC-07K; 2KC; 2KHC-05K; 4CC; 4CHC-9K; 4DC; 4DHC-7K; 4EC; 4EHC-6K; 4FC; 4FHC-5K; 4KTC-10K 1 ZL; ZM 2 HA 4;HA 5;HA6; HG4; HG 5; HG 6;HG 7;HG 8; HGX4/310-4; HGX4/385-4; HGX4/464-4; HGX4/ or 3 Bock HA 12; HA22; HA34;HG 12;HG22; HG34; HGX12P/40-4; HGX12P/50-4;HGX12P/60-4;HGX12P/ HGX22P/110-4; HGX22P/125-4;HGX22P/160-4; HGX22P/190-4; HGX34P/215-4; HGX34P/ Carrier EA; ER; 0 or 3 Copeland 4CC; 6CC; D2; D3; D4; D6.H; D6.S; D9; DM 0 or 3 ZF;ZS 2 K Series (except the listed for adapter 1);SCC500 B; SCC750 B; SCC1500 B; SCC1900 B; SCC2000 B; SCC2500 Dorin B; SCS340 D; SCS351 D; SCS362 D;SCS373 D; SCS385 D; SCS3K8 D; H Series (Except the listed for adapter 1) 0 or 3 H1; K 100CC; K 100CS; K 150CC; K 150 CS; K 180CC; K 180CS; K200CS; K230CS; K235CC; K240SB; K400CC; K50CS; K75CC; K75CS; SCC250 B; SCC300 B; SCC350 B; SCC380 B 1 Frascold A; A-SK; B; D; D-SK; F; F-SK; Q-SK; S; S-SK; V; W;Z 0 or 3 Prestcold P2;P3:P4;P6;P8;P9 0 or 3 L`Unité Hermétique TAG;TAH 1 Maneurope LT; MT; SM; SZ; 1 45

46 46 46

47 47 MUFFLERS ENTLADUNGSDÄMPFER CO2 TECNA 47

48 MUFFLERS ENTLADUNGSDÄMPFER 48 Upright and Horizontal Assembly. For better results, a vibration absorber must be installed before the muffler. Working pressure: 130 bar Montage in senkrechter und waagerechter Posi on. Für bessere Ergebnisse vor dem Entladungsdämpfer einen Vibtra onsdämmer einbauen. Betriebsdruck: 130 bar 130 bar -10/80ºC Model Modell Code ODS L (mm) D (mm) SDS bar /8" ,2 CAT. 0 SDS bar /2" ,2 SDS bar /8" ,2 SDS bar /8" ,2 CAT. I SDS bar /8" ,2 SDS bar /8" ,2 VALID FOR TRANSCRITICAL CO 2 FÜR GEEIGNET CO 2 UBERKRITISCH ALL THE MODELS ARE PAINTED IN BLACK ALLE MODELLE SIND SCHWARZ ANGESTRICHEN 48

49 49 VALVES VENTILE CO2 49

50 ROTALOCK VALVES / ROTALOCKVENTILE ROTALOCK STRAIGHT ADAPTER / GERADE ROTALOCKADAPTER 50 Weld type steel Valves with coating anticorrosion. Sealed plastic plug of great capacity to avoid losses of refrigerant. All the valves include two gauges of ¼ " SAE (*) with brass plugs. Compatible only with fluids of the group II. Other measurements on demand. Please consult Ventile Stahlschweißen mit Rostschutzbeschichtung Dichtung aus Plastik mit hoher Kapazität, um das Austreten von Kühlmittel zu vermeiden. Alle Ventile mit zwei Anschlüssen ¼ SAE (*) mit Blechdeckel. Kategorie I gemäß PED 97/23/CE. Nur mit Flüssigkeiten der Gruppe II kompatibel. MODEL MODELL CODE Ø A (ROTALOCK) Ø B (ODS) E mm A-1 x 3/8 A UNS 3/8 30 A-1 x 5/8 A UNS 5/8 35 A-1 x 1/2 A UNS 1/2 35 A-1 x 7/8 A UNS 7/8 35 A-11/4 x 5/8 A ¼ 12UNF 5/ A-11/4 x 3/4 A ¼ 12UNF ¾ 37.7 A-11/4 x 7/8 A ¼ 12UNF 7/ A-1 1/4 x 1 1/8 A ¼ 12UNF 1 1/ A-1 3/4x 1 1/8 A /4 12UNF 1 1/ A-1 3/4x 1 3/8 A /4 12UNF 1 3/ A-1 3/4x 1 5/8 A /4 12UNF 1 5/ A-2 1/4x 1 5/8 A /4 12UNF 1 5/ A-2 1/4x 2 1/8 A /4 12UNF 2 1/ VALID FOR ALL THE REFRIGERANTS HFC: R22, R134a, R404A, R507,..ETC FÜR ALLE KÜHLMITTEL GEEIGNET HFC: R22, R134a, R404A, R507,..ETC 50

51 ROTALOCK VALVES ROTALOCKVENTILE bar -40/140ºC CODE MODEL / MODELL Body (mm) A (mm) B (inch) D (mm) Kv (m 3 /h) A Rotalock Valve 1" x 3/8" SAE " - 3,8 A Rotalock Valve 1" x 3/8" ODS " 9,8 3,8 A Rotalock Valve 1" x 1/2" ODS " 12,95 3,8 A Rotalock Valve 1" x 5/8" ODS " 16,2 3,8 A Rotalock Valve 1" x 7/8" ODS " 22,5 3,8 A Rotalock Valve 1 1/4" x 5/8" SAE /4" - 3,8 A Rotalock Valve 1 1/4" x 5/8" ODS /4" 16,2 A Rotalock Valve 1 1/4" x 1/2" ODS /4" 12,95 A Rotalock Valve 1 1/4" x 7/8" ODS /4" 22,5 3,8 3,8 8,5 A Rotalock Valve 1 1/4" x 1 1/8" ODS /4" 28,85 8,5 A Rotalock Valve 1 3/4" x 7/8" ODS /4" 22,5 8,5 A Rotalock Valve 1 3/4" x 1 1/8" ODS /4" 28,85 8,5 A F Rotalock Valve 1 3/4" x 1 1/8" ODS /4" 28,85 17 A Rotalock Valve 1 3/4" x 1 3/8" ODS /4" 35,3 17 A Rotalock Valve 1 3/4" x 1 5/8" ODS /4" 41,2 17 A Rotalock Valve 2 1/4" x 2 1/8" ODS /4" 54,4 35 A Rotalock Valve 2 1/4" x 1 5/8" ODS /4" 41,6 35 VALID FOR ALL THE REFRIGERANTS HFC: R22, R134a, R404A, R507,..ETC FÜR ALLE KÜHLMITTEL GEEIGNET HFC: R22, R134a, R404A, R507,..ETC 51

52 BALL VALVES KUGELVENTILE 52 Commonly used for isolating purposes. Suitable for HFC and HCFC refrigerants / lubricants They can be used for both liquid and gas applications Bidirectional flow Üblicher Einsatz zur Isolation. Mit den Kühlmitteln HFC und HCFC und mit Schmierstoffen kompatibel. Geeignet für den Einsatz mit Flüssigkeiten und Gasen. Fluss in beide Richtungen. Der Hohlraum der Kugel verhindert Überdrücke. 45 bar -40/120ºC WITHOUT OBUS / OHNE VENTILEINSATZ 45 bar -40/120ºC WITH OBUS / MIT VENTILEINSATZ CODE CONNECTION Anschluss MODEL MODELL Kv (m 3 /h) P=1bar CODE CONNECTION Anschluss MODEL MODELL Kv (m 3 /h) P=1bar A /4 VB-1 1,3 A /8 VB-2 3,3 A ½ VB-3 6 A /8 VB- 4 14,7 A /4 VB A /8 VB A /8 VB A /8 VB A /8 VB A /8 VB A /8 VB A /8 VB A /4 VB-1-O 1,3 A /8 VB-2-O 3,3 A ½ VB-3-O 6 A /8 VB- 4-O 14,7 A /4 VB- 5-O 18 A /8 VB- 6-O 27 A /8 VB- 7-O 41 A /8 VB- 8-O 69 A /8 VB- 9-O 96 A /8 VB- 10-O 175 A /8 VB- 11-O 190 A /8 VB- 12-O 390 VALID FOR ALL THE REFRIGERANTS HFC: R22, R134a, R404A, R507,..ETC FÜR ALLE KÜHLMITTEL GEEIGNET HFC: R22, R134a, R404A, R507,..ETC 52

53 SAFETY AND SERVICE VALVES SICHERHEITSVENTIL / BETRIEBSVENTILE 53 SAFETY VALVES FOR CO 2 SICHERHEITSVENTIL FÜR CO 2 CODE MODEL / MODELL A /4 NPT X 3/8 SAE A /8 NPT X 1/2 SAE A /2 NPT X 5/8 SAE A /2 NPT X 3/4 GAS (P) A /2 NPT X 3/4 GAS (G) A /2 NPT X 1 1/4 GAS A /4 NPT X 3/4 GAS A NPT X 1 1/4 GAS SAFETY VALVES FOR CO 2 (TRANSCRITICAL ) - 130bar SICHERHEITSVENTIL FÜR CO 2 (ÜBERKRITISCHE ) - 130bar CODE MODEL / MODELL A NEW 1/2 NPT X 1 1/4 GAS 45bar SERVICE VALVES / BETRIEBSVENTILE CODE A A A MODEL / MODELL 1/4" X ¼" SAE 3/8" X 3/8" SAE 1/2" X 1/2" SAE To consult others models / NACHFRAGEN VALID FOR ALL THE REFRIGERANTS HFC: R22, R134a, R404A, R507,..ETC FÜR ALLE KÜHLMITTEL GEEIGNET HFC: R22, R134a, R404A, R507,..ETC 53

54 SIGHTGLASS AND ROTALOCK ACCESORIES ROTALOCK- SICHTFENSTER UND ZUBEHÖRTEILE 54 SIGHT GLASSES / ANZEIGEN CODE MODEL / MODELL PS (bar) A Sight Glass 1" NPT (130 bar) 130 A Complete Welded Sight Glass 1" (Type 2) A Sight Glass 1/2" NPT (Type 1) 45 A Sight Glass 1" NPT (Type 1) 45 A Sight Glass 1 1/4" NPT (Type 1) HFC HFC HFC HFC HFC CODE ROTALOCK SIGHTGLASS ROTALOCK-SICHTFENSTER MODELL PS (bar) A Rotalock Sightglass 1 ¾ A Rotalock Soghtglass 2 ¼ HFC HFC 54

55 55 55

56 IN THE WORLD 56 Offices-Warehouses / Büros und Lagerstandorte Head Office (Factory) / Zentrales Büro (Werk) Countries where Tecnac sells / Ländern, in die Tecnac verkau OUR CATALOGUE ALWAYS UPDATED IN OUR WEB SITE : 56

57 57 WIR AKTUALISIEREN DIESEN KATALOG AUF UNSERER WEBSEITE STÄNDIG : 57

58 58 WORKING WITH WORLDWIDE Tecnac is present in over 33 countries, therefore our main of objec ve is to make Tecnac products reachable to all Refrigera on and Air Condi oning manufacturer worldwide. Would you be interested in distribu ng our product in your country, please contact ARBEITEN SIE MIT ZUSAMMEN IN ALLER WELT Tecnac ist in über 30 Ländern vertreten. Unser Ziel ist, allen Fachleuten der Kühltechnik den Zugang zu Tecnac- Erzeugnissen zu ermöglichen. Setzen Sie sich bi e mit uns in Verbindung, wenn Ihr Unternehmen am Vertrieb unserer Produkte in Ihrem Land oder Ihrer Region interessiert ist. tecnac@tecnac.net This catalogue is constantly updated in our web: Wir aktualisieren diesen Katalog auf unserer Webseite ständig: CONTACT / KONTAKT: tecnac@tecnac.net 58

59 Técnicas Ambientales del Centro, S.L. 59 Total or partial reproduction of this catalogue is strictly forbidden. You may not reproduce, transmit, modify, connect or give public use or another purpose to this information, directly, by any means, without the prior authorization of S.L. The information included in this document has been compiled by S.L. from original technical documents, good practices and other sources which we deem reliable. In no case, will S.L. be responsible for any type of damages, losses, claims or expenses for any information acquired by this catalogue. ( S.L. reserves all rights to change his products without prior notice) WARRANTY The products are guaranteed against any construction defect for a period of TWELVE MONTHS from the delivery date. This warranty shall not applied if the products have been subject to accident, neglect or misuse as well as if they are subject to repair, alteration or modifications by anyone other than ourselves,unless writing approval. The customer shall inspect the goods immediately on delivery and shall within five days of delivery send written notice to of any defect in material or workmanship in the products or that the products delivered are not as stated in the order Under the period of warranty agrees to substitute or repair the defective material after his expert s report. For an inspection and technical report, the customer must return as his own expenses, the defective goods to factory in similar package conditions to the first shipment and with the insurance included. In the event of the inspection find the goods The costs of the installation and removal for the guarantee material as well as the labor costs, travel, transport and refrigerant involved, shall not be borne by The returned material must include the serial number, the invoice number and the defect found. After an exhaustive expert s inspection, will inform the customer about the conclusions of it and the acceptance or not of the failure under guarantee. In the even of the expert s inspection find the goods faulty, will repair/replace, and returns goods to customer address free of charge. As per prior agreement with the customer, could reimburse the customer for the invoice price and transport The rejected material will be property of. The responsibility of won t take into account for any loses, storage material or refrigerant gas due to the defect material. Dieser Katalog darf weder ganz noch teilweise wiedergegeben, in Abspielsystemen gespeichert oder über elektronische, mechanische Medien fotokopiert oder gespeichert werden, ohne dass S.L. hierzu vorher das Einverständnis gibt. Jegliche Angaben in diesem Katalog basieren auf Informa on aus originalen technischen Dokumenten und anderen Quellen innerhalb der guten Praxis und es wird keine rechtliche Ha ung für Fehler oder Auslassungen übernommen Design und Ausführung: S.L ( S.L. behält sich das Recht vor, seine Produkte ohne Vorankündigung zu verändern.) GARANTIE Tecnac gewährt auf seine Produkte ein Jahr Garantie ab Versanddatum. Nach einem entsprechenden Gutachten nimmt Tecnac zurückgewiesene Materialien entgegen. Solche zurückgenommenen Materialien sind Eigentum von Tecnac. Zu allen zurückgewiesenen Materialien sind die Seriennummern anzugeben. Die Haftung von Tecnac umfasst keine Personen- oder Sachschäden, Verluste von eingelagertem Material, Kühlmittelgas oder Betriebsbzw. Nutzungsverluste. Die Tecnac-Garantie beschränkt sich auf den Ersatz des betreffenden Produkts. Tecnac behält sich die Möglichkeit vor, anstelle des Produktersatzes eine Zahlung zu tätigen. Bei Missbrauch seitens des Kunden oder Eingriffen an den Geräten ohne vorheriges Einverständnis von Tecnac tritt die Garantie außer Kraft. Tecnac behält sich vor, nach einem umfassenden Gutachten einige der oben genannten Punkte in die Garantiebedingungen aufzunehmen. Mit der Annahme der ersten Bestellung akzeptiert der Kunde die vorliegenden allgemeinen Konditionen. 59

60 60 HEAD OFFICE C/ Bronce, Loeches Madrid (España) Tel. (34) AMERICA P.O. Box Mill Creek, WA Seattle (EEUU) Tel. (206) Mobile MEXICO Bosques de Canada No Bosques del Valle San Pedro Garza García NL MEXICO Tel POLAND Adres do korespondencji: Al. Krakowska 80a Stefanowo tel.: CHILE C/ Taurus 9320 Vitacura Santiago de Chile Rut EGYPT 20Ezz El-Din Omar, Espatis - El-Haram, Giza (Egypt) Tel / GREECE 65, Davaki Str., Kallithea / Attiki Greece Tel: greece@tecnac.net ISRAEL 9 Hamefalsim Str. Kiryat Arie Petah-Tikva Israel Tel: israel@tecnac.net - HOLLAND Augsburgstraat AA ROTTERDAM holland@tecnac.net Técnicas Ambientales del Centro, S.L. G.R C/ Bronce, Loeches Madrid (España) Telf.: (34) Fax.: (34) REV.01 60

TECNAC. growing up with you CATALOGUE CO 2. years. Técnicas Ambientales del Centro S.L.

TECNAC. growing up with you CATALOGUE CO 2. years. Técnicas Ambientales del Centro S.L. years growing up with you C CATALOGUE CO 2 Components for Refrigeration and Air Conditioning Komponenten für Kühlung und Klimaanlage 2019-2020 Técnicas Ambientales del Centro S.L. OUR VISION This catalog

Mehr

Umschaltventile Magnete

Umschaltventile Magnete Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC

Mehr

Umschaltventile Magnet

Umschaltventile Magnet Umschaltventile Magnet DFE1/3 estellnr. Typ 2-11-1 DFE1/318ES-W22-12VDC 2-11-1 DFE1/318ES-W22-24VDC 24-2-116 DFE1/318ES-Y22-12VDC 24-2-117 DFE1/318ES-Y22-24VDC Weitere Umschaltventil Varianten auf nfrage

Mehr

Overview thermostat/ temperature controller

Overview thermostat/ temperature controller Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:

Mehr

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN

Mehr

TECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS

TECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS TECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS 113 ÖLKÜHLER - AIR/OIL COOLERS ALUMINIUM ALUMINUM Typ Models Öldurchfluss Oil flow capacity Lüfter Fan Kühlleistung Performance (40 C) Arbeits-- druck Pressure

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

P A max. 100bar A P max. 16bar

P A max. 100bar A P max. 16bar 1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

2/2-way solenoid valve - Type 218

2/2-way solenoid valve - Type 218 - direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Inhaltsverzeichnis Index

Inhaltsverzeichnis Index Inhaltsverzeichnis Index Typ Type Seite Page FDL 7-1 FDR 7-2 FMR 7-3 7-0-1 Zahnradmengenteiler Rotary geared flow divider Zahnradmengenteiler Typ FDL Rotary geared flow divider type FDL Technische Daten

Mehr

Electrical tests on Bosch unit injectors

Electrical tests on Bosch unit injectors Valid for Bosch unit injectors with order numbers 0 414 700 / 0 414 701 / 0 414 702 Parts Kit Magnet*: - F00H.N37.925 - F00H.N37.933 - F00H.N37.934 * For allocation to the 10-place Bosch order number,

Mehr

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

A P max. 16bar P R max. 64bar R P max. 16bar

A P max. 16bar P R max. 64bar R P max. 16bar direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff

Mehr

servogesteuert pilot operated

servogesteuert pilot operated 1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung

Mehr

DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES

DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES Ecksicherheitsventile aus Rotguss mit Nirofeder Typ 606 GF/GFL/tGF für neutrale Flüssigkeiten,Dampf und gasförmige Medien Safety valves made of red brass

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm Ultrakompakt 87 x 54 x 26 mm + Ultra compact 87 x 54 x 26 mm + + Bis zu 57 W oder 2 x 27 W Up to 57 W or 2 x 27 W Einzigartig klein Unique small size Der Klassiker The classic Darf es ein bisschen mehr

Mehr

2/2-way solenoid valve - Type 239

2/2-way solenoid valve - Type 239 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 10 40 Druckbereich Gehäusewerkstoff Messing Dichtw erkstoff Sitzventil mit

Mehr

Snap-in switch for switches PSE, MSM and MCS 30

Snap-in switch for switches PSE, MSM and MCS 30 Product manual Snap-in switch for switches PSE, MSM and MCS 30 CONTENTS 1. PRODUCT DESCRIPTION 2. DATA AND DIMENSIONAL DRAWINGS 2.1. Technical Data 2.2. Dimensions of PSE with a Mounting Diameter 19 mm

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich

Mehr

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T Startfolie B/S/H/ 1 Product division Event Location Refrigeration Side by Side USA B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T 2 Side-by-Side Appliances Models: Bosch Siemens KAN 56V** KAN58A** KA58NA**with

Mehr

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 15 50

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff

Mehr

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar] NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung

Mehr

Vacuum. Vakuum C-VLR 0,01 0, Auswahldaten Klauen-Vakuumpumpen Reihe C-VLR

Vacuum. Vakuum C-VLR 0,01 0, Auswahldaten Klauen-Vakuumpumpen Reihe C-VLR Vakuum Vacuum C-VLR 0,01 0,1 1 10 100 1000 1 10 100 1000 10000 Vacuum in mbar (abs.) Saugvermögen in m 3 Suction capacity in m 3 /h Auswahldaten Klauen-Vakuumpumpen Reihe C-VLR Selection data for claw

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135 zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff

Mehr

Electrical testing of Bosch common rail piezo injectors

Electrical testing of Bosch common rail piezo injectors Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid

Mehr

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H Rotary Dampers with high-torque range WRD-H 67 WRD-H 85 WRD-H 128 WRD-H 161 WRD-H 21 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Applications: - Mechanical and

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direct acting with isolating diaphragm fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Schnellentlüftungsventil Nennweite DN 2,0 2,5 Schnellentlüftung DN 6,0 Druckbereich Gehäusewerkstoff

Mehr

Electrical testing of Bosch common rail Injectors

Electrical testing of Bosch common rail Injectors Electrical testing of Bosch common rail Injectors Contents: 1. Adapter cable for Hybridtester FSA 050 (article number 0 684 010 050 / 1 687 023 571) 2. Electrical testing of Bosch common rail solenoid

Mehr

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.

Mehr

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Newest Generation of the BS2 Corrosion/Warning and Measurement System Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing

Mehr

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,

Mehr

2/2-way plastic solenoid valve - Type 110

2/2-way plastic solenoid valve - Type 110 - direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 6,0 Druckbereich Sitzventil

Mehr

Hazards and measures against hazards by implementation of safe pneumatic circuits

Hazards and measures against hazards by implementation of safe pneumatic circuits Application of EN ISO 13849-1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free

Mehr

3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled

3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50

Mehr

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow 1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

Mechanisch betätigte Ventile Typ 46 NW 2 3/2-Wege Sitzventile Direktgesteuert

Mechanisch betätigte Ventile Typ 46 NW 2 3/2-Wege Sitzventile Direktgesteuert NW /-Wege Sitzventile mm Orifice /-Way Poppet Valves Dieses Sitzventil wurde speziell für den Einsatz in Schalttafeln und Betätigungseinrichtungen entwickelt. Durch seinen sechseckigen Grundkörper ist

Mehr

OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2.

OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2. Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2. Elektromotoren und Gerätebau Barleben GmbH 2 Inhaltsverzeichnis Page 1 Use 4 2 Design features 4 2.1 Test

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

technical documents for extraction and filter devices type series 1000

technical documents for extraction and filter devices type series 1000 technical documents for extraction and filter devices type series 1000 5. suction flange 6. filter combination 7. fan / motor 8. air outlet Functional principle: A special fan (3) with a high pressure

Mehr

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719 Fire and explosion hazard ATEX 137 1999/92/EG und ATEX 95 2014/34/EU Danger assessment and determination of explosion protection zone for the test space as well as the installation site ATEX-Check list

Mehr

Pilot Project Biogas-powered Micro-gas-turbine

Pilot Project Biogas-powered Micro-gas-turbine 1/18 Pilot Project Biogas-powered Micro-gas-turbine Supported by the Hessischen Ministerium für Wirtschaft, Verkehr und Landesentwicklung Speaker Details 2/18 Jan Müller Works at Institute of Solar Energy

Mehr

SCHLAUE LÖSUNGEN FÜR IHRE ANWENDUNGEN SMART SOLUTIONS FOR YOUR APPLICATIONS

SCHLAUE LÖSUNGEN FÜR IHRE ANWENDUNGEN SMART SOLUTIONS FOR YOUR APPLICATIONS SCHLAUE LÖSUNGEN FÜR IHRE ANWENDUNGEN SMART SOLUTIONS FOR YOUR APPLICATIONS block.eu Schlau: Mit der FLUID-TECHNOLOGY schaffen Sie 50% mehr Platz im Schrank. Smart: With the FLUID-TECHNOLOGY you create

Mehr

E1 M1 P5 TK2 K2 20,6. hohe elektrische Nennleistung Schlüsselabzugstellung (Option) Wahl Aus/Ein. Umschalter/Wechsler. mit Federumkehr oder Umschalter

E1 M1 P5 TK2 K2 20,6. hohe elektrische Nennleistung Schlüsselabzugstellung (Option) Wahl Aus/Ein. Umschalter/Wechsler. mit Federumkehr oder Umschalter Frontplattenmontage Schlüsselschalter Baureihe E1 M1 P5 TK2 K2 Lochausschnitt (mm) 15,1 15,1 15,1 15,1 20,6 16,2/22,5 19,1 Charakteristik zweipoliger Umschalter/ Wechsler oder drei Schaltkreisschaltfunktionen

Mehr

Bronze BR - B 584 Spring: Stainless steel / AISI 316 Valve disc: Stainless steel / AISI 316 L

Bronze BR - B 584 Spring: Stainless steel / AISI 316 Valve disc: Stainless steel / AISI 316 L Technische Daten BAUFORM -teilige Körperkonstruktion, Zwischenflanschbauweise mit breiter Dichtfl äche nach DIN. ANSCHLUß DN 5 bis DN EINBAULAGE Beliebig, vorzugsweise für waagerechten oder senkrechten

Mehr

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... DIGICONTROL- Gerätedatenblatt F-SPT-U www.gfr.de [82252] Kategorie: Sensoren und Wächter Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... Anwendung Der Druckmessumformer F-SPT-U...

Mehr

Datenblatt. P-series PDU 2.5/4/4AN

Datenblatt. P-series PDU 2.5/4/4AN Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means

Mehr

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012 fremdgesteuert externally controlled Schaltfunktion function Elektrischer Anschluss M12x1 electrical connector M12x1 Die Ventile arbeiten als Druckwaage und werden im Bypass eingesetzt. Der Mediumsdruck

Mehr

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten. EZ-0225-V10 Air Bearing Spindle High accurancy air bearing spindle with direct drive. Equipped with an water-cooled synchronous motor (frequency at nominal speed 400 Hz), Power output 1880 W. Rotary encoder

Mehr

Hülsenfreilauf / HF One-way Clutch Bearing

Hülsenfreilauf / HF One-way Clutch Bearing BEARINGS A L L FOR B E YOUR A R IFUTURE N G S Hülsenfreilauf / HF One-way Clutch Bearing Zen Ball Bearings are manufactured to the highest quality for standard and non-standard applications. Our technical

Mehr

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL AU-D21 Digital Audio Optical Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Front Panel Diagram 2 3.2 Rear Panel Diagram 2 3.3 Side

Mehr

Baureihe 280 / 281 / 282 Type 280 / 281 / 282

Baureihe 280 / 281 / 282 Type 280 / 281 / 282 1 fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10

Mehr

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC Oil / Air cooler ASATT 11 12V/24V DC Öl /Luftkühler ASATT 11 12V/24V DC Pressure drop at 30 cst Druckabfall bei 30 cst Specific Cooling Performance Spezifische Kühlleistung TECHNICAL DATA TECHNISCHE DATEN

Mehr

Ex-Barriere für Diagnoseeinheit SITRANS DA400 / Ex-barrier for diagnostics unit SITRANS DA400 7MJ2010-1AA 0032

Ex-Barriere für Diagnoseeinheit SITRANS DA400 / Ex-barrier for diagnostics unit SITRANS DA400 7MJ2010-1AA 0032 Ex-Barriere für Diagnoseeinheit SITRANS DA400 / Ex-barrier for diagnostics unit SITRANS DA400 7MJ2010-1AA 0032 Warnung Elektrischer Anschluss in explosionsgefährdeten Bereichen Anschluss und Inbetriebnahme

Mehr

ABB i-bus EIB. EIB Power Supply Units

ABB i-bus EIB. EIB Power Supply Units ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!

Mehr

Copyright by Max Weishaupt GmbH, D Schwendi

Copyright by Max Weishaupt GmbH, D Schwendi Improving Energy Efficiency through Burner Retrofit Overview Typical Boiler Plant Cost Factors Biggest Efficiency Losses in a boiler system Radiation Losses Incomplete Combustion Blowdown Stack Losses

Mehr

Spannungskonstante LED Treiber. Constant Voltage LED Drivers LAMP-CONCEPT.CH

Spannungskonstante LED Treiber. Constant Voltage LED Drivers LAMP-CONCEPT.CH Spannungskonstante LED Treiber Constant Voltage LED Drivers Optotronic Produkteigenschaften: Optimale Versorgungseinheiten für RaLED Flex Module Vielseitiger Anwendungsbereich durch Ausgangsleistungen

Mehr

Control shut-off butterfly valves DN 50 DN 400 PN

Control shut-off butterfly valves DN 50 DN 400 PN Features Applications include HEVAC and drinking water systems, sanitary and industrial plants for control or shut-off of water and steam -10...+110 C Leakage rate: tight sealing Control and shut-off butterfly

Mehr

Specification. DESIGN Swing check valves for return fl ow prevention in piping systems to be mounted directly between fl anges acc. to DIN.

Specification. DESIGN Swing check valves for return fl ow prevention in piping systems to be mounted directly between fl anges acc. to DIN. Technische Daten BAUFORM Rückschlagklappen zur Rückfl ussverhinderung in Rohrleitungssystemen für den Einbau zwischen DIN Flanschen. ANSCHLUß Flansch DN32 DN500 bemessen für Flansch nach PN16 BETRIEBSDRUCK

Mehr

Connecting bend 90 connecting bend parts that serve as a connection between the hydraulic separator and the compact manifold.

Connecting bend 90 connecting bend parts that serve as a connection between the hydraulic separator and the compact manifold. Technical data sheet MultiFlow Expert Components of the MultiFlow Expert - hydraulic separator - connecting bends - multiple compact manifolds [D] Manufacturer certification Description MultiFlow Expert

Mehr

rot red braun brown rot red RS-8 rot red braun brown R S V~

rot red braun brown rot red RS-8 rot red braun brown R S V~ Kleiner Ring 9 /Germany Phone: 0049 4122 / 977 381 Fax: 0049 4122 / 977 382 Sample connections: Feedback module with integrated detection of occupied tracks for the RS-feedback bus (Lenz Digital plus)

Mehr

Attenuator and Distribution System Zehnder ComfoWell 220

Attenuator and Distribution System Zehnder ComfoWell 220 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for

Mehr

2/2-way plastic solenoid valve - Type 104

2/2-way plastic solenoid valve - Type 104 - direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 1,0 2,5 Druckbereich Gehäusewerkstoff

Mehr

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H 6030 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Material: - Aluminium and steel Applications:

Mehr

Zöllige Radialrillenkugellager - Sondergrössen Inch Series / Commercial Inch Series.

Zöllige Radialrillenkugellager - Sondergrössen Inch Series / Commercial Inch Series. BEARINGS A L L FOR B E YOUR A R IFUTURE N G S 1 Zöllige Radialrillenkugellager - Sondergrössen Inch Series / Commercial Inch Series Zen Ball Bearings are manufactured to the highest quality for standard

Mehr

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H 12070 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Material: - Aluminium and steel Applications:

Mehr

Motorenreihe Einphasen Wechselstrom

Motorenreihe Einphasen Wechselstrom Einphasen Wechselstrommotorensingle phase motors enreihe Einphasen Wechselstrom line single-phase Eckdaten Key data n s Gehäusematerial Frame material Number of poles Leistung Output 63 bis 100 63 to 100

Mehr

Walter Buchmayr Ges.m.b.H.

Walter Buchmayr Ges.m.b.H. Seite 1/10 Chapter Description Page 1 Advantages 3 2 Performance description 4 3 Settings 5 4 Options 6 5 Technical data 7 6 Pictures 8 http://members.aon.at/buchmayrgmbh e-mail: walter.buchmayr.gmbh@aon.at

Mehr

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs 2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with

Mehr

EUROTEC Namur Solenoid Valve

EUROTEC Namur Solenoid Valve Beschreibung Description - Kolbenschieber-Magnetventil NAMUR, indirekt gesteuert, 5/2- und 3/2-wege, mit Magnetspule und Gerätestecker mit Ausgang M16 für Kabeldurchmesser 5-6mm - Leichtes Umschalten von

Mehr

Handbuch KP AS. User Manual KP AS

Handbuch KP AS. User Manual KP AS 170410 1 KP AS Handbuch KP AS Drucksensor mit hoher Meßgenauigkeit Deutsch Seite 2 User Manual KP AS Pressure Sensor with High Accuracy English page 4 170410 2 KP AS DEUTSCH 1. Allgemeines Die KPAS-Drucksensoren

Mehr

Electrical testing of Bosch common rail solenoid valve (MV) injectors

Electrical testing of Bosch common rail solenoid valve (MV) injectors Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445

Mehr

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-LAN Installationsvarianten Das DELTA 2.4 W-LAN System kann in verschiedenen Varianten installiert werden:

Mehr

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H. ZU 0859 Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H www.knick.de Bauart und Funktion Der Endlagenschalter ZU 0859 wandelt die pneumatischen Endlagen signale,

Mehr

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control Technische Daten BAUFORM Druckgesteuertes Nadelventil mit aufgebautem Stellungsregler PG01. Specification DESIGN Pressure actuated needle valve with electropneumatic positioner. Artikel: AND STEUERFUNKTIONEN

Mehr

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,

Mehr

Motorenreihe Einphasen Wechselstrom

Motorenreihe Einphasen Wechselstrom enreihe Einphasen Wechselstrom line single-phase Eckdaten Key data n s Gehäusematerial Frame material Number of poles Leistung Output 63 bis 100 63 to 100 Aluminium Aluminum 2 und 4 2 and 4 0,12 bis 3

Mehr

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator Bauart Nennweite DN 8 DN 50 Anschluss Kugelhahn mit pneumatischem Schwenkantrieb G1/4 G2 Betriebsdruck Messing: DN15 DN20 = PN30 DN25 = PN16 DN32 DN50 = PN10 Edelstahl: PN63 Gehäusewerkstoff Armatur: Edelstahl

Mehr

Flüssigkeitsgekühlte Synchron-Generatoren

Flüssigkeitsgekühlte Synchron-Generatoren Serie SDF SDB Flüssigkeitsgekühlte Synchron-Generatoren Schutzart IP 65 Liquid cooled Sync. Generators Protection class IP 65 Serie SDF IP 65 SDF IP 65 series EME sorgt für Strom, wo immer Sie ihn brauchen.

Mehr

Datenblatt data sheet

Datenblatt data sheet Seite page 1 von of 5 Datenblatt data sheet Typ: / type: 55440120 Kurzbezeichnung: LED-Schwenkstrahler chrom short term: led luminaire turnable round chrome Produktbeschreibung: product description: LED-

Mehr

Speetronics Technologies

Speetronics Technologies Speetronics Technologies spee tronics T E C H N O L O G I E S Design / Engineering Manufacturing / Assembly Quality Management / Logistics Know-How Durch das fundierte Know How ist Speetronics GmbH ein

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 DGV - Datenblätter DGV - Datasheets DGV DGV Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] Drehwinkel Rotary angle [ ] Drehmoment Torque [Ncm] DGV-35.95 35/35 x 27.5 95 DGV-50.95

Mehr

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver Operating Instructions LED Mast Double Luminaire Callisto SC DB, incl. Inclination Adjustment, Single-Chip Technology (Please, read carefully before starting operation) Version: 16.01.2017 Model 369-M

Mehr