3-Line Filters for Converters and Power Electronics B84143-G*-R110 B84143-G*-R112

Größe: px
Ab Seite anzeigen:

Download "3-Line Filters for Converters and Power Electronics B84143-G*-R110 B84143-G*-R112"

Transkript

1 B8443-G*-R0 B8443-G*-R2 Power line filters for three-phase systems Rated voltage 4/275 and 520/300 V~, 50/ Hz Rated current 8 to 220 A Construction Three-line filter Metal case Book size Features High insertion loss Low leakage current Optimized footprint saves space Litz wires on the load side reduce mounting time Low weight Degree of protection: IP 20 ) Design based on EN , CSA 22.2 No Optimized for long motor cables and operation under full load UL 283 approval for type -R0, for -R2 UL and CSA approval pending Applications Frequency converters for motor drives, e.g. elevators pumps traction systems conveyor systems HVAC systems (heating, ventilation and air conditioning) Wind farms Power supplies Terminals Line: Safe-to-touch terminal blocks Load: Litz wires on component: Manufacturer s logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging: Manufacturer s logo, ordering code ) In accordance with IEC 529:989; EN 529:99; DIN VDE /0

2 B8443-G*-R0 B8443-G*-R2 Typical circuit diagrams B8443-G8 G20-R0/-R2 LINE LOAD SSB286-Z B8443-G36 G220-R0/-R2 LINE LOAD SSB /0

3 B8443-G*-R0 B8443-G*-R2 Technical data Rated voltage V R Rated current I R Test voltage V P Overload capability Leakage current I leak Climatic category 4/275 V~, 50/ Hz (type -R0) 520/300 V~, 50/ Hz (type -R2) Referred to C ambient temperature 770 V, 2 s (line/line) 2700 V, 2 s (lines/case),5 I R for 3 min per hour or 2,5 I R for 30 s per hour at 4 V~, 50 Hz 25/00/2 ( 25 C/+ 00 C/2 days damp heat test) in accordance with EN 068- Characteristics and ordering codes I R Terminal cross section I leak R typ Approx. Ordering code A line side: terminal blocks mm 2 load side: litz wires mm 2 typ. ) ma mω weight kg 8 4,5 < 6,3 B8443-G8-R* ,5 < 6 0,3 B8443-G20-R* ,0 < 6 5,2 2,8 B8443-G36-R* < 6 2,4 3,3 B8443-G50-R* < 6,8 4,4 B8443-G66-R* < 6,2 4,9 B8443-G90-R* < 6,0 7,5 B8443-G20-R* < 6 0,7 8,0 B8443-G50-R* < 6 0,4,5 B8443-G220-R* Compilation of ordering code Replace the asterisk * by the code number for the required version: 0 = 4 / 275 V 2 = 520 / 300 V ) At rated operation 24 03/0

4 B8443-G*-R0 B8443-G*-R2 Dimensional drawings B8443-G8-R*, B8443-G20-R* 50 Anschlussklemmen blocks 4 mm Terminal ±0 3 5 M6 x ± Aderendhülse Wire end ferrule 25±0,3 46 SSB29- B8443-G36-R* 250 0±0 Anschluss- Terminal klemmen blocks 66 mm M6 x ± 30 Aderendhülse Wire end ferrule 35±0,3 56 SSB /0

5 B8443-G*-R0 B8443-G*-R2 B8443-G50-R* ±0 Anschluss- Terminal klemmen blocks 6 mm M6 x ± 35±0,3 56 Aderendhülse Wire end ferrule SSB293-H B8443-G66-R*, B8443-G90-R* ±0 Anschlussklemmen blocks 25 mm Terminal M0 x ± 55±0,3 76 Aderendhülse Wire end ferrule SSB294-Q /0

6 B8443-G*-R0 B8443-G*-R2 B8443-G20-R*, B8443-G50-R* ±0 Terminal Anschlussblocks klemmen 50 mm M0 x ± Aderendhülse Wire end ferrule 65±0,3 86 SSB295-Y B8443-G220-R* Anschlussklemmen Terminal blocks 95 mm Litz wire Litze Aderendhülse Wire end ferrule 0 500± M0 x ± 85±0,3 06 SSB348-T /0

7 B8443-G*-R0 B8443-G*-R2 Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B8443-G8-R* B8443-G20-R* 20 SSB288-G 20 SSB289-P db db α e 00 α e fhz fhz 8 B8443-G36 G220-R* 20 db α e 00 SSB290-S fhz /0

8 Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 7 09, 867 München, DEUTSCHLAND EPCOS AG Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 7 09, 867 Munich, GERMANY EPCOS AG All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices.

3-Line Filters for Converters and Power Electronics B84143-B*-R110 B84143-B*-R112

3-Line Filters for Converters and Power Electronics B84143-B*-R110 B84143-B*-R112 B83-B*-R Power line ilters or three-phase systems Rated voltage /275 and 5/ V~, / Hz Rated current 8 to A Construction Three-line ilter Metal case Book size Features Very high insertion loss Low leakage

Mehr

for Converters and Power Electronics

for Converters and Power Electronics or Converters and Power Electronics Power line ilters or single-phase systems Rated voltage 25 V~, 5/ Hz Rated current 8 A to 25 A Construction Two-line ilter Metal case Features Very high insertion loss

Mehr

SIFI-A Series. SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A

SIFI-A Series. SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A 2-ine Filters SIFI- Series 4111 SIFI- for normal insertion loss Rated voltage 2 V~, / Hz Rated current 1 to Construction Two-line filter Metal case Polyurethane potting (U 94 V-) Features Compact design

Mehr

for Installations and Systems

for Installations and Systems or Installations and Systems Power line ilters or three-phase systems Rated voltage 4/25 V~, 5/ Hz Rated voltage 6 to 125 A Construction Four-line ilter Metal case Features High insertion loss Compact,

Mehr

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V B99* C 93 C 99 Applications Overcurrent and short-circuit protection b 3, max. Features Lead-free terminals Manufacturer s logo and type designation stamped on in white Low resistance For rated currents

Mehr

P V W/set N / 20 % 2530 B66317-G-X130 N / 20 % < 0,59

P V W/set N / 20 % 2530 B66317-G-X130 N / 20 % < 0,59 Core B66317 In accordance with IEC 61246 E cores are supplied as single units Magnetic characteristics (per set) Σl/A = 1,1 mm 1 l e = 57,5 mm A e = 52,5 mm 2 A min = 51,5 mm 2 V e = 3 020 mm 3 Approx.

Mehr

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3 Core B66361 In accordance with IEC 61185 Quality assurance per UTE 83313-001/ CECC 25 301-001 (material N27) For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied

Mehr

P V W/set N / 20 % 2460 B66311-G-X130 N / 20 % < 0,27

P V W/set N / 20 % 2460 B66311-G-X130 N / 20 % < 0,27 Core B663 In accordance with IEC 6246 E cores are supplied as single units Magnetic characteristics (per set) Σl/A =,44 mm l e = 46,3 mm A e = 32, mm 2 A min = 3,9 mm 2 V e = 490 mm 3 Approx. weight 7,3

Mehr

P 4,6 4,1. Magnetic characteristics (per set) Σl/A = 2,6 mm 1 l e = 7,6 mm A e = 2,8 mm 2 V e = 21,3 mm 3. Approx. weight 0,17 g/set.

P 4,6 4,1. Magnetic characteristics (per set) Σl/A = 2,6 mm 1 l e = 7,6 mm A e = 2,8 mm 2 V e = 21,3 mm 3. Approx. weight 0,17 g/set. Core B65495 Miniature pot cores for adjustable miniature inductors One of the two cores is equipped with an internal thread for the adjusting screw The unit can be fixed to the terminal carrier by glue

Mehr

EMI Suppression Capacitors X2 / 275 and 300 Vac B3292 B32922 X2 MKP/SH 40/100/21/C

EMI Suppression Capacitors X2 / 275 and 300 Vac B3292 B32922 X2 MKP/SH 40/100/21/C EMI Suppression Capacitors X2 / 275 and 300 Vac B3292 X2 capacitors with very small dimensions Rated ac voltage 275 and 300 V, 50/60 Hz Construction Dielectric: polypropylene (MKP) Plastic case (UL 94

Mehr

Sensors Motor Protection, Triple Sensors

Sensors Motor Protection, Triple Sensors B900 M 00 Applications Thermal protection of winding in electric motors Limit temperature monitoring Features Thermistor pellets with insulating encapsulation in series connection (triple sensor) Low-resistance

Mehr

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx.

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx. Core B65843 In accordance with IEC 61596 For transformers featuring high inductance and low overall height For power applications EP cores are supplied in sets Magnetic characteristics (per set) Σl/A =

Mehr

mm 1 mm mm 2 mm 3 P V

mm 1 mm mm 2 mm 3 P V Core B6553 In accordance with IEC 6033 Pot cores are supplied in sets Magnetic characteristics (per set) Σl/A l e A e A min V e with center hole,0 5,9 5,9 252,0 Approx. weight (per set) without center

Mehr

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Construction Round varistor element, leaded Coating: epoxy resin, flame-retardant

Mehr

SIMID 1210-100. Size 1210 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 100 µh Rated current 65 to 800 ma

SIMID 1210-100. Size 1210 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 100 µh Rated current 65 to 800 ma Size 12 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 0 µh Rated current 65 to 800 ma Construction Ceramic or ferrite core Laser-welded winding Flame-retardant encapsulation Features Very wide temperature

Mehr

The following products presented in this data sheet are being withdrawn. B66307F0000X142 B66307F0000X

The following products presented in this data sheet are being withdrawn. B66307F0000X142 B66307F0000X E/ELP Cores Series/Type: E 16/8/5 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B66307F0000X142

Mehr

ETD 29/16/10 Core B66358 _ 9,8 0,6

ETD 29/16/10 Core B66358 _ 9,8 0,6 Core ETD 29/16/10 through ETD 59/31/22 In accordance with IEC 61185 For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied as single units Magnetic characteristics

Mehr

The following products presented in this data sheet are being withdrawn. B65816D

The following products presented in this data sheet are being withdrawn. B65816D RM Cores Series/Type: RM 12 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B65816D20050000

Mehr

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3 Core B66361 In accordance with IEC 61185 Quality assurance per UTE 83313-001/ CECC 25 301-001 (material N27) For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied

Mehr

mm 1 mm mm 2 mm 3 µ e Ordering code

mm 1 mm mm 2 mm 3 µ e Ordering code Core B65517 In accordance with IEC 60133 Pot cores are supplied in sets Magnetic characteristics (per set) Σl/A l e A e A min V e with center hole 1,25 12,2 9,8 120 without center hole 1,13 13,4 11,9 9,3

Mehr

SMD Varistors Monolithic; Standard Series

SMD Varistors Monolithic; Standard Series Construction Cylindrical varistor element, encapsulated Encapsulation: thermoplast, flame-retardant to UL 94-0 Termination: tinned copper alloy Features Electrical equivalents to leaded types S05/S07 up

Mehr

mm 1 mm mm 2 mm 3 P V

mm 1 mm mm 2 mm 3 P V Core B65671 In accordance with IEC 60133 Pot cores are supplied in sets Magnetic characteristics (per set) Σl/A l e A e A min V e Approx. weight (per set) Gapped with center hole 0,4 37,2 93 76,5 3 460

Mehr

Single-Ended Capacitors Very Low Impedance 105 C B41858

Single-Ended Capacitors Very Low Impedance 105 C B41858 Single-Ended Capacitors Very Low Impedance 5 C Long-life grade capacitors for professional applications Applications For use in output circuits of switch-mode power supplies of compact design For professional

Mehr

B81133 X2 MKT/SH 40/100/21/C B81133 X2 MKT/SH 40/100/21/C. EMI Suppression Capacitors X2 / 275 Vac Not for new design

B81133 X2 MKT/SH 40/100/21/C B81133 X2 MKT/SH 40/100/21/C. EMI Suppression Capacitors X2 / 275 Vac Not for new design EMI Suppression Capacitors X2 / X2 capacitors with small dimensions Rated ac voltage 275 V, 50/60 Hz 1) Construction Dielectric: polyester (MKT) Internal series connection Plastic case (UL 94 V-0) Epoxy

Mehr

EMI Suppression Capacitors X2 / 275 Vac

EMI Suppression Capacitors X2 / 275 Vac EMI Suppression Capacitors X2 / B81130 X2 capacitors with very small dimensions Rated ac voltage 275 V, 50/60 Hz Construction ielectric: polypropylene (MKP) Plastic case (UL 94 V-0) Epoxy resin sealing,

Mehr

The following products presented in this data sheet are being withdrawn. B66414B6008T002 2003-08-08 2004-02-29 2004-08-31

The following products presented in this data sheet are being withdrawn. B66414B6008T002 2003-08-08 2004-02-29 2004-08-31 EFD/EV/DE Cores Series/Type: EFD /8/ The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B66B6008T002

Mehr

Overcurrent Protection Leaded Disks, Uncoated, 380 V to 1000 V

Overcurrent Protection Leaded Disks, Uncoated, 380 V to 1000 V Leaded Dik, Uncoated, 38 V to V B97** B 7 B 774 Application Overcurrent and hort-circuit protection Feature Lead-free terminal Manufacturer logo, date code and type deignation tamped on in black UL approval

Mehr

EMI Suppression Capacitors Y2 / 250 Vac

EMI Suppression Capacitors Y2 / 250 Vac EMI Suppression Capacitors Y2 / B81122 Y2 capacitors Rated ac voltage 250 V, 50/60 Hz Construction Dielectric: for = 10 mm: polyester (MKT), for 15 mm: polypropylene (MKP) Internal series connection (for

Mehr

The following products presented in this data sheet are being withdrawn. B66305F0000X142 B66305F0000X

The following products presented in this data sheet are being withdrawn. B66305F0000X142 B66305F0000X E/ELP Cores Series/Type: E 13/7/4 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B66305F0000X142

Mehr

The following products presented in this data sheet are being withdrawn.

The following products presented in this data sheet are being withdrawn. RM Cores Series/Type: RM 10 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B65814N1011D001

Mehr

PM/P/P Cores Halves/EP/TT/PR Cores

PM/P/P Cores Halves/EP/TT/PR Cores PM/P/P Cores Halves/EP/TT/PR Cores Series/Type: P 14 x 8 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders

Mehr

PM/P/P Cores Halves/EP/TT/PR Cores

PM/P/P Cores Halves/EP/TT/PR Cores PM/P/P Cores Halves/EP/TT/PR Cores Series/Type: P 36 x 22 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders

Mehr

Switching Applications PTC Thermistors in Plastic Case, 63 V to 220 V

Switching Applications PTC Thermistors in Plastic Case, 63 V to 220 V Switching Application PTC Thermitor in Platic Cae, 63 V to 22 V J 28... J 29 Application Delayed witching of load For frequent witching 6,3 max. 6,3 max. Feature Encaed thermitor dik with clamp contact

Mehr

Ferrites and Accessories

Ferrites and Accessories Ferrites and Accessories Series/Type: RM 4 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments

Mehr

B45192, B Tantalum Chip Capacitors Low Profile, H max = 1,5 mm; Standard and Low ESR

B45192, B Tantalum Chip Capacitors Low Profile, H max = 1,5 mm; Standard and Low ESR New series Construction Polar tantalum capacitors with solid electrolyte Flame-retardant plastic case (UL 94 V-0) Optionally tinned or gold-plated terminals Maximum height 1,5 mm Features High volumetric

Mehr

B45196-H, B45198-H. Tantalum Chip Capacitors HighCap

B45196-H, B45198-H. Tantalum Chip Capacitors HighCap Construction Polar tantalum capacitors with solid electrolyte Flame-retardant plastic case (UL 94 V-0) Optionally tinned or gold-plated terminals Features Ultra-high volumetric efficiency Excellent solderability

Mehr

B45194, B Tantalum Chip Capacitors Low Profile, H max = 2 mm; Standard and Low ESR

B45194, B Tantalum Chip Capacitors Low Profile, H max = 2 mm; Standard and Low ESR New series Construction Polar tantalum capacitors with solid electrolyte Flame-retardant plastic case (UL 94 V-0) Optionally tinned or gold-plated terminals Maximum height 2,0 mm Features High volumetric

Mehr

Capacitors with Screw Terminals

Capacitors with Screw Terminals Capacitors with Screw Terminals 105 C B 41 560, B 41 580 LL grade Compact low-voltage type For professional power supplies Construction Charge-discharge proof, polar luminum case with insulating sleeve

Mehr

PM/P/P Cores Halves/EP/TT/PR Cores

PM/P/P Cores Halves/EP/TT/PR Cores PM/P/P Cores Halves/EP/TT/PR Cores Series/Type: P 18 x 11 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders

Mehr

SMD Varistors MLV; Telecom Series

SMD Varistors MLV; Telecom Series ML; Telecom Series Construction Multilayer technology Termination: nickel barrier (CT series) or silver palladium (CN series) No plastic or epoxy encapsulation assures better than UL 94-0 flaability rating

Mehr

Dickfilm-Widerstände Thick-Film Resistors

Dickfilm-Widerstände Thick-Film Resistors Dickfilm-Widerstände Thick-Film Resistors Dickfilm-Widerstände werden universell eingesetzt: in der Uhrenindustrie, Kommunikations-/Datentechnik,... bis hin zur Kfz-Elektronik. Verwendung finden die Baugrößen

Mehr

The following products presented in this data sheet are being withdrawn.

The following products presented in this data sheet are being withdrawn. RM Cores Series/Type: RM The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B80C0000R0 B80C0000R048

Mehr

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1)

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1) Kundenspezifische, unterbaufähige Netzdrosseln für Siemens-Umrichter der Serien SINAMICS GC und G mit Leistungsmodul PM240-2 (Standard-Variante). Die Drosseln sind seitlich ohne Abstand anreihbar. Line

Mehr

Datenblatt. P-series PDU 2.5/4/4AN

Datenblatt. P-series PDU 2.5/4/4AN Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means

Mehr

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 2100A, C2

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 2100A, C2 3 x 528 V + Neutral-Line, 7 to 2100A, C2 Application and performance characteristics EMI Improvement of drive system: Enables conformity of the drive system to EN 55011, to IEC 61800-3 Preferred for use

Mehr

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 630 A, C2

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 630 A, C2 Application and performance characteristics EMI Improvement of drive system: Enables conformity of the drive system to EN 55011, to IEC 61800-3 Preferred for use with long motor cables Typically C2 limits

Mehr

Allgemeine Technische Daten / General Technical Data

Allgemeine Technische Daten / General Technical Data Strom / Current [A] Strom / Current [A] Unterbaufähige Motordrosseln für hohe Kabellängen. Geeignet für Siemens-Umrichter der Serien SINAMICS G120C und G120 mit Leistungsmodul PM240-2 (Standard-Variante).

Mehr

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE 100.000 h geeignet für Zone 2 Ex + 100,000 h suitable for zone 2 hazardous areas + + Für Netz- und Batteriebetrieb For mains and battery supply Lädt und überwacht die Batterie Integrated battery management

Mehr

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W Kraftvoll bis 200 W + Powerful up to 200 W + + Kleine Bauform Small size Betriebsanzeige über LED und Meldekontakt Status LED and signal contact Zuverlässig entkeimen. Reliable desinfection. Linear V UV

Mehr

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm Ultrakompakt 87 x 54 x 26 mm + Ultra compact 87 x 54 x 26 mm + + Bis zu 57 W oder 2 x 27 W Up to 57 W or 2 x 27 W Einzigartig klein Unique small size Der Klassiker The classic Darf es ein bisschen mehr

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Applicant: Product: Certificate of conformity Generating unit, NS-protection Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs 2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with page 1 of the. Blankwiderstands-Durchflußerwärmer, geschlossen Bare Element

Mehr

Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range

Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range ü CAGE-CLAMP Anschlussklemmen CAGE-CLAMP terminals ü Bis 250 VA mit Kombifußplatte* Up to

Mehr

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH nach DIN EN ISO/IEC 17025:2005 Gültigkeitsdauer: 09.02.2017 bis 18.10.2020 Ausstellungsdatum: 09.02.2017 Urkundeninhaber: PEHLA - Gesellschaft für elektrische Hochleistungsprüfungen

Mehr

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters Application and performance characteristics Typically used to comply with EMC emission standards Reduce conducted emissions over the frequency range 150 khz to 30 MHz Suitable for Industrial, Railway,

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with page 1 of the. Warmwasserspeicher, geschlossen Storage water heater,

Mehr

3 Phase Filter 3F690-xxx x 690V, 10 to 400 A, C2

3 Phase Filter 3F690-xxx x 690V, 10 to 400 A, C2 3 x 690V, 10 to 400 A, C2 he filter design and the used materials comply with the requirements of UL 508 and IC 60939. ypische Anwendungen ie Netzfilter der aureihe 3690-xxx.230 sind für die ntstörung

Mehr

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Anlage zur Akkreditierungsurkunde D-PL-11055-09-00 nach DIN EN ISO/IEC 17025:2005 Gültigkeitsdauer: 09.02.27 bis 18.10.2020 Ausstellungsdatum: 09.02.27 Urkundeninhaber:

Mehr

Tachogeneratoren Vollwelle mit EURO-Flansch B10 Mit eigener Lagerung

Tachogeneratoren Vollwelle mit EURO-Flansch B10 Mit eigener Lagerung Tachogeneratoren Vollwelle mit EURO-Flansch B10 Mit eigener Lagerung, Merkmale Kurze Reaktionszeit Leerlaufspannung 10 150 mv pro U/min Redundanter Ausgang (TDPZ) EURO-Flansch B10 / Vollwelle ø11 mm Sehr

Mehr

Hochstrom-Druckkontakte für Dauerströme bis 400 A. High Current Probes up to 400 amps cont. Ausgabe 7/2009 DE EN. Edition 7/2009 DE EN

Hochstrom-Druckkontakte für Dauerströme bis 400 A. High Current Probes up to 400 amps cont. Ausgabe 7/2009 DE EN. Edition 7/2009 DE EN Hochstrom-Druckkontakte für Dauerströme bis 400 usgabe 7/2009 DE EN High Current Probes up to 400 amps cont. Edition 7/2009 DE EN Impressum und Bestellhinweise Company and Ordering Information Unsere

Mehr

336 Wannenstiftleisten RM 1,27mm, gerade/gewinkelt Box Headers, 1.27mm Pitch, Straight/Right-Angled

336 Wannenstiftleisten RM 1,27mm, gerade/gewinkelt Box Headers, 1.27mm Pitch, Straight/Right-Angled Technische Daten / Technical Data Isolierkörper Thermoplastischer Kunststoff, nach UL94 V-0 Insulator Thermoplastic, rated UL94 V-0 Kontaktmaterial Messing Contact Material Brass Kontaktoberfläche Vergoldet

Mehr

Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS

Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS Typennummer I0FAE3xxF100XxxxxS RFI Filter I0FAE4xxF100XxxxxS Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS Technische Daten Typ E355F E375F E411F 100D... 100D... 100D... Bemessungsstrom [A] 120.0 / 105.0

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Elektronisches Vorschaltgerät für Hochdruck-Entladungslampen Electronic

Mehr

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x T E C H N I S C H E I N F O R M AT I O N Diese Technische Information ergänzt die Betriebsanleitungen der Barcodescanner-Familie CLV6xx mit Angaben zur UL60950-Zertifizierung. Betriebsanleitung CLV62x

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Durchflußerwärmer, geschlossen Instantaneous water heater,

Mehr

Serviceinformation Nr. 02/11

Serviceinformation Nr. 02/11 Serviceinformation Nr. 02/11 vom: 06.10.2011 von: BAM 1. Software Navigator und Release Notes Auf unserer Homepage unter www.idm-energie.at/de/navigator-software.html steht ab sofort eine neue Version

Mehr

HEAG 151, 152, 153, 154 Digital Converter

HEAG 151, 152, 153, 154 Digital Converter Montage- und Betriebsanleitung Installation and operating instructions MB095-11055704 Baumer_HEAG151-152-153-154_II_DE-EN (16A1) HEAG 151, 152, 153, 154 Digital Converter 1-2 Allgemeine Hinweise - Funktionsweise

Mehr

Montageanleitung / Mounting instruction / Manuel de montage. D: Abmessung bis zur Klemme. Mat. Nr Typennummer

Montageanleitung / Mounting instruction / Manuel de montage. D: Abmessung bis zur Klemme. Mat. Nr Typennummer Typennummer RFI Filter I0FAE3xxF100XxxxxS Filter Typ 3~ RFI Filter I0FAE3xxF100XxxxxS Technische Daten Typ E330F E337F E345F 100D 100D 100D Bemessungsstrom [A] 55.00/45.70 69.00/57.00 100.00/86.00 Ableitstrom

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Certificate of conformity Generating unit, NS-protection Applicant: Product: Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle

Mehr

ICL Series Rail-Mount Hydraulic Magnetic Circuit Breaker

ICL Series Rail-Mount Hydraulic Magnetic Circuit Breaker Ihr autorisierter Distributor: Neumüller Elektronik GmbH info@hq-schutzschalter.de ICL Series Rail-Mount Hydraulic Magnetic Circuit Breaker Introduction 133 Configurations 134 Operating Characteristics

Mehr

VDE Prüf- und Zertifizierungsinstitut Gutachten mit Fertigungsüberwachung

VDE Prüf- und Zertifizierungsinstitut Gutachten mit Fertigungsüberwachung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des Gutachtens mit Fertigungsüberwachung Nr.. surveillance No.. USV-Zubehör UPS-Accessories Typ(en) / Type(s): A) PDM35xxIEC-yyy B) PDM13xxIEC-yyy

Mehr

Händler Preisliste Trade Price List 2015

Händler Preisliste Trade Price List 2015 Händler Preisliste Trade Price List 2015 gültig ab / valid from 01.03.2015 Qualität die verbindet Driven by Quality Sehr geehrter Kunde, zu unserer neuen Preisliste möchten wir Ihnen nachfolgend einige

Mehr

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC AC-RIDER 80VA WWW.AC-RIDER.COM TÜV Rheinland geprüfte Sicherheit Besondere Merkmale Features 12 VDC Eingang 12 VDC input Hoher Wirkungsgrad High efficiency Überlast / Kurzschlußfest Overload / Short-circuit

Mehr

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.

Mehr

ABB i-bus EIB. EIB Power Supply Units

ABB i-bus EIB. EIB Power Supply Units ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!

Mehr

VDE Prüf- und Zertifizierungsinstitut Gutachten mit Fertigungsüberwachung

VDE Prüf- und Zertifizierungsinstitut Gutachten mit Fertigungsüberwachung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des Gutachtens mit Fertigungsüberwachung Nr.. surveillance No.. Halogenfreies Installationskabel mit verbessertem Verhalten im Brandfall für

Mehr

FMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0)8684 18-0, info@rosenberger.de, www.rosenberger.com

FMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0)8684 18-0, info@rosenberger.de, www.rosenberger.com The extremely small FMC connector series Flexible Microstrip Connectors are designed for PCB applications in the tightest spaces. Using bullets, equalization of radial and axial misalignments in board-to-board

Mehr

Ex solenoid interlocks // Ex AZM 415

Ex solenoid interlocks // Ex AZM 415 Features/Options Ex zone 1 and 21 Special version up to +90 C ambient temperature for dust Ex zone 21 available (HU) Two Ex switch inserts in one enclosure Spring-to-lock or power-to-lock principle Problem-free

Mehr

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL Sender/Empfänger mit Outdoor-Box Merkmale LWL-SBR, Übertragungsweiten bis zu 1500 m Wandlung üblicher Rechtecksignale

Mehr

Ex emergency pull-wire switches // Ex ZS 75 S

Ex emergency pull-wire switches // Ex ZS 75 S Features/Options Ex zone 1 and 21 Metal enclosure 2 or 4 contacts Wire length up to 2 x 100 m Release by push button (VD) Available without unlocking mechanism (per EN 60947-5-1) Wire pull and breakage

Mehr

LS3/5A customer questionnaire

LS3/5A customer questionnaire LS3/5A customer questionnaire LS3/5A BBC original 15 Ω Autotrafo 3 4 5 6 2 TAP SELECTOR 7 C 2A C 2B LOW INPUT HIGH BBC Original Version KEF B110 [SP1003) 8Ω Spendor Original Layout Please check the xover

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle

Mehr

Lufft UMB Sensor Overview

Lufft UMB Sensor Overview Lufft Sensor Overview Wind Radiance (solar radiation) Titan Ventus WS310 Platinum WS301/303 Gold V200A WS300 WS400 WS304 Professional WS200 WS401 WS302 Radiance (solar radiation) Radiation 2 Channel EPANDER

Mehr

Cloud for Customer Learning Resources. Customer

Cloud for Customer Learning Resources. Customer Cloud for Customer Learning Resources Customer Business Center Logon to Business Center for Cloud Solutions from SAP & choose Cloud for Customer https://www.sme.sap.com/irj/sme/ 2013 SAP AG or an SAP affiliate

Mehr

Sine-Filter 3AFS400-xxx 3 x 500 V, 2,5 to 1000 A, 1,5 to 18 khz

Sine-Filter 3AFS400-xxx 3 x 500 V, 2,5 to 1000 A, 1,5 to 18 khz Application and performance characteristics Improvement of drive system: Increases the applicable motor cable length Reduction of motor noise Protects and increases engine life time by: limination of voltage

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. bwasserpumpe Sanitary pump Typ(en) / Type(s) a) GENIX

Mehr

Motorenreihe Einphasen Wechselstrom

Motorenreihe Einphasen Wechselstrom Einphasen Wechselstrommotorensingle phase motors enreihe Einphasen Wechselstrom line single-phase Eckdaten Key data n s Gehäusematerial Frame material Number of poles Leistung Output 63 bis 100 63 to 100

Mehr

Control shut-off butterfly valves DN 50 DN 400 PN

Control shut-off butterfly valves DN 50 DN 400 PN Features Applications include HEVAC and drinking water systems, sanitary and industrial plants for control or shut-off of water and steam -10...+110 C Leakage rate: tight sealing Control and shut-off butterfly

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Einbauteil für IT Geräte Component for IT equipment Typ(en)

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with 1 of the. Schaltschrank-Heizelement Switch cabinet heating element mit Lüfter with

Mehr

Serie/Series L-BV5. Typ / Type 2BV5 110 2BV5 111 2BV5 121 2BV5 131 2BV5 161. Alle Rechte vorbehalten. All rights reserved.

Serie/Series L-BV5. Typ / Type 2BV5 110 2BV5 111 2BV5 121 2BV5 131 2BV5 161. Alle Rechte vorbehalten. All rights reserved. Flüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors Ersatzteilliste Spare part list Serie/Series L-BV5 Typ / Type 2BV5 110 2BV5 111 2BV5 121 2BV5 131 2BV5 161 Gardner Denver

Mehr

miditech 4merge 4-fach MIDI Merger mit :

miditech 4merge 4-fach MIDI Merger mit : miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with page 1 of the. Steckdose Socket-outlet Typ(en) / Type(s): 6211..EMS Si/I

Mehr

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.

Mehr

EMV-Bauelemente EMC Components

EMV-Bauelemente EMC Components EMV-Bauelemente EMC Components SIMIDs werden für die nieder- und hochfrequente Entkopplung von Signal- und Steuerkreisen sowie zum Aufbau von Schwingkreisen eingesetzt. Typische Anwendungsgebiete sind:

Mehr