Kuhnke Technical Data. Contact Details

Größe: px
Ab Seite anzeigen:

Download "Kuhnke Technical Data. Contact Details"

Transkript

1 Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogues, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details Kuhnke sales and service in North America Ellis/Kuhnke Controls 13 Lewis Street Unit A-, Eatontown NJ 0774 USA T: (00) T: (73) F: (73) Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

2 Bistable Solenoids

3 BI BI Bestellformel BI F 4 V DC 0 % ED Order specifications Hubmagnet Bauart BI Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Lötpins (Rastermaß) F L Coil terminals Flying leads ( cm standard length) Soldering pins (grid dimensions) Nennspannung (Standardspannung) 1) 4 Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 30 V DC 1) Other voltages are available on request up to lieferbar 30 V DC Gewicht: Magnet: ca. 6 g Anker: ca. 1,6 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = C) Isolationsgruppe nach: VDE 01 C 7 Prüfspannung: 00 V (eff) Schutzart: IP 00 Bi eight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 6 g appr. 1.6 g 4 V DC cm E (max. permissible temperature = C) Insulation group according to: VDE 01 C 7 Test voltage: 00 V (eff) Protection: IP 00 1, 16 3,4, ±0,1 Maße im angezogenem Zustand Ø1, Dimensions given with armature in fully home position Hubrichtung Ø4 Ø3 Direction of stroke Zul. rel. Einschaltdauer (ED) % 0 % Perm. duty cycle (ED) Nennaufnahme P 0 Anzugszeit (ED),6 1 Nominal coil power P 0 Actuation time (ED) Abfallzeit 7 Drop-out time %ED Kraft-eg-Diagramm F = f (s) Federkraft Permanentkraft Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer icklung ohne Rückholfeder Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 1 0, 0, 0,1 0 0, 1 1,, S [mm] 0 Force vs. Stroke diagramm F = f (s) spring force permanent force Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature without return spring stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 46 Main catalogue

4 BI 13 BI 13 Bestellformel BI 13 F 4 V DC % ED Order specifications Hubmagnet Bauart BI 13 Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Lötpins 0,63 (Rastermaß,9 mm) F L Coil terminals Flying leads ( cm standard length) Soldering pins 0.63 (grid dimensions.9 mm) Nennspannung (Standardspannung) 1) 4 Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) % ED Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 30 V DC 1) Other voltages are available on request up to lieferbar 30 V DC Gewicht: Magnet: ca. 3 g Anker: ca. 6 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = C) Isolationsgruppe nach: VDE 01 C 7 Prüfspannung: 00 V (eff) Schutzart: IP Bi 13-F 4V= %ED ±0,3 Ø1, Ø3 eight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 3 g appr. 6 g 4 V DC cm E (max. permissible temperature = C) Insulation group according to: VDE 01 C 7 Test voltage: 00 V (eff) Protection: IP Ø11 Ø6 0,3 3-0, 3, Ø M 6 Maße im angezogenem Zustand Dimensions given with armature in fully home position Hubrichtung 6 1 Direction of stroke Zul. rel. Einschaltdauer (ED) % % Perm. duty cycle (ED) Nennaufnahme P 0 Anzugszeit (ED) 7 14 Nominal coil power P 0 Actuation time (ED) Abfallzeit 1 Drop-out time %ED F [N] Kraft-eg-Diagramm F = f (s) Federkraft Permanentkraft 1 0, Force vs. Stroke diagramm F = f (s) spring force permanent force Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer icklung ohne Rückholfeder Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0, 0, S [mm] Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature without return spring stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 47 Main catalogue

5 Bestellformel F 4 V DC % ED Order specifications Hubmagnet Bauart BI 17 Linear solenoid Design type Anschlußart Litze (Standardlänge cm) F Coil terminals Flying leads ( cm standard length) Nennspannung (Standardspannung) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 4 % ED Nominal voltage (standard voltage) 1) Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 60 V DC 1) Other voltages are available on request up to lieferbar 60 V DC Gewicht: Magnet: ca. 46 g Anker: ca. 1 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = C) Isolationsgruppe nach: VDE 01 C 7 Prüfspannung: 00 V (eff) Schutzart: IP 00 Bi 17-F 4 V DC % ED eight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 46 g appr. 1 g 4 V DC cm E (max. permissible temperature = C) Insulation group according to: VDE 01 C 7 Test voltage: 00 V (eff) Protection: IP 00 Zul. rel. Einschaltdauer (ED) % % Perm. duty cycle (ED) Nennaufnahme P 0 Anzugszeit (ED) 9, Nominal coil power P 0 Actuation time (ED) Abfallzeit 11 Drop-out time %ED Kraft-eg-Diagramm F = f (s) Federkraft Permanentkraft Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer icklung ohne Rückholfeder Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] S [mm] Force vs. Stroke diagramm F = f (s) spring force permanent force Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature without return spring stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 4 Main catalogue

6 , 3, Ø M, 1 17 Ø1 Ø7 M3 Ø6 0,4 4 ±0,3 Maße im angezogenem Zustand Hubrichtung Dimensions given with armature in fully home position Direction of stroke Magnet Hauptkatalog 49 Main catalogue

7 Magnet Hauptkatalog 0 Main catalogue

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Bestellformel BI 8 F 24 V DC 15 % ED Order specifications Hubmagnet

Bestellformel BI 8 F 24 V DC 15 % ED Order specifications Hubmagnet Bestellformel % ED Order specifications Litze (Standardlänge 0 cm) Lötpins (Rastermaß) L lying leads (0 cm standard length) Soldering pins (grid dimensions) Nennspannung (Standardspannung) ) 4 Nominal

Mehr

Bestellformel V 30 N 24 V DC 100 % ED Order specifications Hubmagnet

Bestellformel V 30 N 24 V DC 100 % ED Order specifications Hubmagnet Bestellformel N % ED Order specifications Hubmagnet V Linear solenoid Bauart 30 Design type Anschlussart Litze (Standardlänge cm) Gerätestecker 1) F N Coil terminals Flying leads ( cm standard length)

Mehr

Bestellformel HU 24 0 F 24 V DC 100 % ED Order specifications Hubmagnet. Design type Pull type solenoid Thrust type solenoid Anschlussart F A

Bestellformel HU 24 0 F 24 V DC 100 % ED Order specifications Hubmagnet. Design type Pull type solenoid Thrust type solenoid Anschlussart F A HU HU Bestellformel HU 0 F V DC 0 % ED Order specifications Hubmagnet HU Linear solenoid Größe Sizes Bauart Zugmagnet Stoßmagnet 0 Design type Pull type solenoid Thrust type solenoid Anschlussart Coil

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GI-50.10 GI-50.10 1 / Hub / stroke = 10mm 110.5 9 68.5 3x M O 0 M6 18 SW5 O50 O6 Magnet bestromt gezeichnet Solenoid illustrated in energised position 6 max. Hub / stroke = 10mm 110.5 39 68.5 3x M O 0

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GKu - Datenblätter GKu - Datasheets AG - CH-40 Andelfingen - Tel. +41 (0)2 30 2 2 - info@islikermagnete.ch - www.islikermagnete.ch GKu GKu Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GM - Datenblätter GM - Datasheets GM GM Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] Hub Stroke [mm] F min F min [N] GM-.05 23 x x 40 5 1.9 GM-26.08 x 26 x 50 8 3.5 GM-35.

Mehr

GM - Miniatur Magnet. GM - Miniature solenoid ISLIKER MAGNETE

GM - Miniatur Magnet. GM - Miniature solenoid ISLIKER MAGNETE GM - Miniatur Magnet GM - GM GM Übersicht overview Baureihe Dimensionen Hub Fmin GM-.05 23 x x 40 5 2 GM-26.08 x 26 x 50 8 5.5 GM-35. 40 x 35 x 60 9 Type Dimensions Stroke Fmin GM-.05 23 x x 40 5 2 GM-26.08

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 DGV - Datenblätter DGV - Datasheets DGV DGV Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] Drehwinkel Rotary angle [ ] Drehmoment Torque [Ncm] DGV-35.95 35/35 x 27.5 95 DGV-50.95

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,

Mehr

-BOO- - F - 24 V DC 100 % ED

-BOO- - F - 24 V DC 100 % ED e s Bestellformel 4 -BOO- - F - 24 V DC ED Order specifications Drehmagnet Rotary solenoid Größe (,, 9) Size (,, 9) Drehwinkel 2 4 2 4 Angular travel 2 4 6 9 Ausführung beidseitiges Wellenende Anschlussart

Mehr

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar] NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,

Mehr

Bestellformel D 5 3 -ROR- - N - 24 V DC 100 % ED Order specifications Drehmagnete. Size (2, 3, 5, 6, 7, 9) Drehwinkel ROR-

Bestellformel D 5 3 -ROR- - N - 24 V DC 100 % ED Order specifications Drehmagnete. Size (2, 3, 5, 6, 7, 9) Drehwinkel ROR- e D s D Bestellformel D 3 -ROR- - N - 24 V DC ED Order specifications Drehmagnete D Rotary solenoids Größe (2, 3,, 6, 7, 9) Size (2, 3,, 6, 7, 9) Drehwinkel 2 3 4 2 3 4 ngular travel 2 3 4 6 9 6 9 6 9

Mehr

Typenreihe GH Lifting Solenoids

Typenreihe GH Lifting Solenoids Hubmagnete Lifting Solenoids Bauart Hubmagnete der Reihe GH können mit Durchmessern zwischen 5 mm und 65 mm und mit Hublängen von 8 bis 60 mm gefertigt werden. Serien mäßig wer den sie mit Wellenenden

Mehr

Typenreihe GY Type Group GY. Klein-Hubmagnete Small lifting solenoids

Typenreihe GY Type Group GY. Klein-Hubmagnete Small lifting solenoids Klein-Hubmagnete Small lifting solenoids Typenreihe GY Type Group GY Bauart Hubmagnete der Reihe GY wer den für Gleichspannungsan schluss geliefert. Die Querschnittsabmessungen (B x H) liegen zwischen

Mehr

GTP - Permanent Elektro Haftmagnet. GTP - Permanent Electro Magnet

GTP - Permanent Elektro Haftmagnet. GTP - Permanent Electro Magnet GTP - GTP - GTP GTP Übersicht overview Baureihe Dimensionen FHalte GTP-20 Ø20 x 22 70 GTP-30 Ø30 x 32 130 GTP-34 Ø34 x 39.6 260 GTP-60 Ø60 x 53.5 620 Type Dimensions Fholding GTP-20 Ø20 x 22 70 GTP-30

Mehr

Typenreihe GH Lifting Solenoids

Typenreihe GH Lifting Solenoids Hubmagnete Lifting Solenoids Bauart Hubmagnete der Reihe GH können mit Durchmessern zwischen 5 mm und 65 mm und mit Hublängen von 8 bis 60 mm gefertigt werden. Serien mäßig wer den sie mit Wellenenden

Mehr

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87 Magnetventile Solenoid Valves Betätigungsmagnet Typ 64 für Baureihe 64/79///7 Type 64 for Series 64/79///7 Elektrische Daten 64er Magnetsystem Elektrische Ausführung: gemäß VDE 050, VDE 00 Ansprechstrom:

Mehr

GTP - Permanent Elektro Haftmagnet Datenblätter. GTP - Permanent electro magnet Datasheets

GTP - Permanent Elektro Haftmagnet Datenblätter. GTP - Permanent electro magnet Datasheets GTP - Datenblätter GTP - Datasheets GTP GTP Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] F Haft F Holding [N] GTP-20 Ø20 x 22 70 GTP-30 Ø30 x 32 130 GTP-34 Ø34 x 39.6 260

Mehr

Klein-Magnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom. Small Solenoids pull or push, double or return operation DC Solenoids

Klein-Magnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom. Small Solenoids pull or push, double or return operation DC Solenoids Klein-Magnete,, Doppel- oder für Gleichstrom Small Solenoids pull or push, DC Solenoids 3 Doppel- oder ISLIKER MAGNETE AG Tel. ++41 (0)52 305 25 25 CH-8450 Andelfingen Fax ++41 (0)52 305 25 35 Switzerland

Mehr

Solenoid Valves. Magnetventile. Type 65 for Series 65/79/81/83/87. Betätigungsmagnet Typ 65 für Baureihe 65/79/81/83/87

Solenoid Valves. Magnetventile. Type 65 for Series 65/79/81/83/87. Betätigungsmagnet Typ 65 für Baureihe 65/79/81/83/87 Magnetventile Solenoid Valves Betätigungsmagnet Typ 65 für Baureihe 65/79///7 Type 65 for Series 65/79///7 Elektrische Daten 65er Magnetsystem Elektrische Ausführung: mäß VDE 050, VDE 00 Ansprechstrom:

Mehr

Standardausführung standard version. Merkmale. Features

Standardausführung standard version. Merkmale. Features Riegelkurve EMT 17 und EMT 18 Retiring Cam EMT 17 and EMT 18 Standardausführung standard version Merkmale alle Stahlteile verzinkt geräuscharm durch starke Dämpfung beim Ein- und Ausschalten robust und

Mehr

Overview thermostat/ temperature controller

Overview thermostat/ temperature controller Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:

Mehr

Umschaltventile Magnete

Umschaltventile Magnete Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC

Mehr

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen Technical Report No. 028-71 30 95685-350 of 22.02.2017 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen

Mehr

Umschaltventile Magnet

Umschaltventile Magnet Umschaltventile Magnet DFE1/3 estellnr. Typ 2-11-1 DFE1/318ES-W22-12VDC 2-11-1 DFE1/318ES-W22-24VDC 24-2-116 DFE1/318ES-Y22-12VDC 24-2-117 DFE1/318ES-Y22-24VDC Weitere Umschaltventil Varianten auf nfrage

Mehr

Electrical tests on Bosch unit injectors

Electrical tests on Bosch unit injectors Valid for Bosch unit injectors with order numbers 0 414 700 / 0 414 701 / 0 414 702 Parts Kit Magnet*: - F00H.N37.925 - F00H.N37.933 - F00H.N37.934 * For allocation to the 10-place Bosch order number,

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details تاریخ 1/25/2 مجتمع فولاد ویان Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDOs and any page number shown is relevant to the original document.

Mehr

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V B99* C 93 C 99 Applications Overcurrent and short-circuit protection b 3, max. Features Lead-free terminals Manufacturer s logo and type designation stamped on in white Low resistance For rated currents

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical ata The following page(s) are extracted from multi-page Kuhnke product catalogues or OMs and any page number shown is relevant to the original document. The P sheets here may have been

Mehr

Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 5,5 2 Pol Leistung/ power: W

Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 5,5 2 Pol Leistung/ power: W Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 5,5 2 Pol Leistung/ power: 10 125 W ESTAN Elektromaschinen und Steuerungsbau GmbH Burgunderstraße 6 D-79418 Schliengen (Germany) 1 Tel:

Mehr

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3

Mehr

Leistung output. Seite page EI48/20,5 12VA 2-3 EI48/20,5 12VA 4-5. safety isolating transformer for safe isolation between in- und output according

Leistung output. Seite page EI48/20,5 12VA 2-3 EI48/20,5 12VA 4-5. safety isolating transformer for safe isolation between in- und output according TYPENREIHE TYPE 484 Sicherheitstransformator safety isolating transformer Typenreihe type 484 Nicht kurzschlussfest / 484T bedingt kurzschlussfest (mit Temperatursicherung) / (with integrated thermal )

Mehr

2/2-way solenoid valve - Type 218

2/2-way solenoid valve - Type 218 - direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Leistung output EI66/23 30VA 2 EI66/23 30VA 3 EI66/34,5 45VA 4 EI66/34,5 45VA 5

Leistung output EI66/23 30VA 2 EI66/23 30VA 3 EI66/34,5 45VA 4 EI66/34,5 45VA 5 BAUREIHE SERIES 660 Sicherheitstransformator safety isolating transformer Typenreihe type 660 Nicht kurzschlussfest / 660T mit Temperatursicherung) / with integrated thermal ) 664 Nicht kurzschlussfest

Mehr

Leistung output. Seite page EI48/16,8 10VA 2-3 EI48/16,8 10VA 4-5. safety isolating transformer for safe isolation between in- und output according

Leistung output. Seite page EI48/16,8 10VA 2-3 EI48/16,8 10VA 4-5. safety isolating transformer for safe isolation between in- und output according TYPENREIHE TYPE 480 Sicherheitstransformator safety isolating transformer Typenreihe type 480 Nicht kurzschlussfest / 480T bedingt kurzschlussfest (mit Temperatursicherung) / (with integrated thermal )

Mehr

EN (DIN

EN (DIN Amphenol Amphenol-Tuchel Electronics GmbH Rundsteckverbinder Circular Connectors Rundsteckverbinder entspricht EN 17 5000 (DIN 4 56) Die Rundsteckverbinder der Serie entsprechen den Anforderungen der EN

Mehr

Leistung output EI42/14,8 4,8VA 2 EI42/14,8 4,8VA 3 EI42/14,8 5,6VA 4 EI42/14,8 5,6VA 5 EI42/20 8VA 6 EI42/20 8VA 7

Leistung output EI42/14,8 4,8VA 2 EI42/14,8 4,8VA 3 EI42/14,8 5,6VA 4 EI42/14,8 5,6VA 5 EI42/20 8VA 6 EI42/20 8VA 7 BAUREIHE SERIES 420 Sicherheitstransformator safety isolating transformer Typenreihe type 421 Nicht kurzschlussfest / 421T mit Temperatursicherung) / 422 Nicht kurzschlussfest / 422T mit Temperatursicherung)

Mehr

Werkszeugnis Motor Typprüfung (2.2) (Prüfbescheinigung nach EN 10204)

Werkszeugnis Motor Typprüfung (2.2) (Prüfbescheinigung nach EN 10204) Werkszeugnis Motor Typprüfung (2.2) (Prüfbescheinigung nach EN 10204) Hubmotor *Motortyp Bemessung- / Betriebsverhalten IEC / EN 034-1 *Betriebsart S 3 - % Umrichterbetrieb Polzahl 4 *Wärmeklasse Th. Cl.

Mehr

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment Technical Report No. 028-7130 95685-050 of 22.02.2017 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen

Mehr

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC Oil / Air cooler ASATT 11 12V/24V DC Öl /Luftkühler ASATT 11 12V/24V DC Pressure drop at 30 cst Druckabfall bei 30 cst Specific Cooling Performance Spezifische Kühlleistung TECHNICAL DATA TECHNISCHE DATEN

Mehr

Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 14 4 Pol Leistung/power: W

Gleichstrom-Permanentmagnetmotor DC-Permanent Magnet Motor Type GfmO 14 4 Pol Leistung/power: W Gleichstrom-Permanentmagnetmotor C-Permanent Magnet Motor Type GfmO 14 4 Pol Leistung/power: 300 1800 W ESTAN Elektromaschinen und Steuerungsbau GmbH Burgunderstraße 6-79418 Schliengen (Germany) Tel: +49

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung

Mehr

Evidence of Performance

Evidence of Performance Air permeability, Watertightness, Resistance to wind load, Operating forces, Mechanical properties, Mechanical durability, Impact resistance Expert Statement No. 15-002226-PR01 (02) Product Designation

Mehr

Micro-RF. 294 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) ,

Micro-RF. 294 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) , Micro-RF components can be used up to 6 GHz in various wireless applications, e. g. cellular and cordless phones, Bluetooth and wireless LAN applications, PDAs (Personal Digital Assistants) or wireless

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Schnellentlüftungsventil Nennweite DN 2,0 2,5 Schnellentlüftung DN 6,0 Druckbereich Gehäusewerkstoff

Mehr

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

P V W/set N / 20 % 2460 B66311-G-X130 N / 20 % < 0,27

P V W/set N / 20 % 2460 B66311-G-X130 N / 20 % < 0,27 Core B663 In accordance with IEC 6246 E cores are supplied as single units Magnetic characteristics (per set) Σl/A =,44 mm l e = 46,3 mm A e = 32, mm 2 A min = 3,9 mm 2 V e = 490 mm 3 Approx. weight 7,3

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Applicant: Product: Certificate of conformity Generating unit, NS-protection Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side)

Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) GIu-50.10 GIu-50.10 Indutrie-Magnet (Umkehrhub) Indutrial Solenoid (return troke) 1 / 4 Hub/troke = 10mm 39 138 96 3x M4 O 40 18 O6 O30 M6 O50 O30 SW5 4 max. 4 max. 4 Magnet betromt geeichnet (Stoeite)

Mehr

P A max. 100bar A P max. 16bar

P A max. 100bar A P max. 16bar 1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN

Mehr

A P max. 16bar P R max. 64bar R P max. 16bar

A P max. 16bar P R max. 64bar R P max. 16bar direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

P V W/set N / 20 % 2530 B66317-G-X130 N / 20 % < 0,59

P V W/set N / 20 % 2530 B66317-G-X130 N / 20 % < 0,59 Core B66317 In accordance with IEC 61246 E cores are supplied as single units Magnetic characteristics (per set) Σl/A = 1,1 mm 1 l e = 57,5 mm A e = 52,5 mm 2 A min = 51,5 mm 2 V e = 3 020 mm 3 Approx.

Mehr

Universalmagnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom. Industrial Solenoids pull or push, double or return operation DC Solenoids

Universalmagnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom. Industrial Solenoids pull or push, double or return operation DC Solenoids Universalmagnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom Industrial Solenoids pull or push, double or return operation DC Solenoids 5 ziehend oder stossend pull or push operation Doppel-

Mehr

Universalmagnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom. Industrial Solenoids pull or push, double or return operation DC Solenoids

Universalmagnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom. Industrial Solenoids pull or push, double or return operation DC Solenoids Universalmagnete ziehend, stossend, Doppel- oder Umkehrhub für Gleichstrom Industrial Solenoids pull or push, double or return operation DC Solenoids 5 ziehend oder stossend pull or push operation Doppel-

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Certificate of conformity Generating unit, NS-protection Applicant: Product: Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff

Mehr

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx.

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx. Core B65843 In accordance with IEC 61596 For transformers featuring high inductance and low overall height For power applications EP cores are supplied in sets Magnetic characteristics (per set) Σl/A =

Mehr

Sensors Motor Protection, Triple Sensors

Sensors Motor Protection, Triple Sensors B900 M 00 Applications Thermal protection of winding in electric motors Limit temperature monitoring Features Thermistor pellets with insulating encapsulation in series connection (triple sensor) Low-resistance

Mehr

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012 fremdgesteuert externally controlled Schaltfunktion function Elektrischer Anschluss M12x1 electrical connector M12x1 Die Ventile arbeiten als Druckwaage und werden im Bypass eingesetzt. Der Mediumsdruck

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135 zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff

Mehr

HF13-Programm HF13 Programme

HF13-Programm HF13 Programme S. 221 HF13 plugs S. 222 HF13-Adapter HF13 adapters S. 223 HF13-Buchsen s 2 HF13 - Programm Die HF-Steckverbindungen der Serie 13/4 werden in Anlagen der Nachrichtentechnik (DIN 47 283 und DIN 47 284),

Mehr

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.

Mehr

SWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS

SWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS SWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS SWC bietet sowohl offene als auch abgedichtete Pendelrollenlager in verschiedenen Ausführungen an: Offene Ausführungen: o Zylindrische Bohrung mit Radialluft

Mehr

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3 Core B66361 In accordance with IEC 61185 Quality assurance per UTE 83313-001/ CECC 25 301-001 (material N27) For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied

Mehr

STRATEGISCHES BETEILIGUNGSCONTROLLING BEI KOMMUNALEN UNTERNEHMEN DER FFENTLICHE ZWECK ALS RICHTSCHNUR FR EIN ZIELGERICHTETE

STRATEGISCHES BETEILIGUNGSCONTROLLING BEI KOMMUNALEN UNTERNEHMEN DER FFENTLICHE ZWECK ALS RICHTSCHNUR FR EIN ZIELGERICHTETE BETEILIGUNGSCONTROLLING BEI KOMMUNALEN UNTERNEHMEN DER FFENTLICHE ZWECK ALS RICHTSCHNUR FR EIN ZIELGERICHTETE PDF-SBBKUDFZARFEZ41-APOM3 123 Page File Size 5,348 KB 3 Feb, 2002 TABLE OF CONTENT Introduction

Mehr

Electromagnetic Flowmeter FXE4000-DE43F

Electromagnetic Flowmeter FXE4000-DE43F Pos: 2 /Grid-Layout/Titelblätter/Ersatzteilblätter/Durchfluss/FXE4000-DE43F @ 65\mod_1350460748604_3101.docx @ 523546 @ @ 1 === Ende der Liste für Textmarke Cover === Spare Parts List SPL/FXE4000-DE43F-EN

Mehr

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow 1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3 3/2 Wegeventil mit PIEZO-Pilotventil Baureihe P20 3/2 way valve with Piezo-pilot valve Series P20 P20 381RF-* NW 2 Eigenerwärmungsfrei Ein Produkt für alle Ex-Bereiche Kompatibel zu Microcontrollern Kompatibel

Mehr

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung 4...7 V 5 V *) Rated Current Nennstrom < 50 ma Sound Output [SPL]at 10 cm Lautstärke[Schalldruckpegel]

Mehr

FMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0)8684 18-0, info@rosenberger.de, www.rosenberger.com

FMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0)8684 18-0, info@rosenberger.de, www.rosenberger.com The extremely small FMC connector series Flexible Microstrip Connectors are designed for PCB applications in the tightest spaces. Using bullets, equalization of radial and axial misalignments in board-to-board

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr