50-Ohm Load MHz W
|
|
- Regina Kohler
- vor 7 Jahren
- Abrufe
Transkript
1 50-Ohm Load MHz W Standard 50-Ohm terminations for small and medium power Suitable for terminating open ports on RF equipment for indoor and /or outdoor applications 0.5 Watt * Type No. K Connector N male MHz VSWR MHz < 1.08 VSWR MHz < 1.15 VSWR MHz < 1.20 Indoor 40 g 90 x 60 x 25 mm Dimensions 33 / 21 mm diameter K Watt * Type No Connector 7-16 male 7-16 female MHz VSWR MHz < 1.10 VSWR MHz < 1.30 Indoor or outdoor (IP65) 120 g Approx. 50 x 90 x 100 mm Dimensions 40 / 32 mm diameter 42 / 29 mm diameter Watt * Type No. K Connector N male MHz VSWR MHz < 1.08 VSWR MHz < 1.15 VSWR MHz < 1.20 Indoor 40 g 90 x 60 x 25 mm Dimensions 30 / 21 mm diameter K / i Subject to alteration. 10 Watt * Type No. K K Connector N female N male MHz VSWR MHz < 1.08 V MHz < 1.15 VSW R MHz < 1.20 Indoor Approx. 250 g 50 x 90 x 100 mm Dimensions (w x h x d) 40 x 82 x 77 mm 40 x 82 x 85 mm (including connector) (including connector) K K , , , K , K , K Page 1 of 2 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. P.O. Box Rosenheim. Germany. Phone Fax
2 50-Ohm Load MHz W 25 Watt * Type No. K K K K Connector N female N male 7-16 female 7-16 male MHz VSWR MHz < 1.08 VSWR MHz < 1.15 VSWR MHz < 1.20 Indoor Approx. 0.5 kg 50 x 100 x 135 mm Dimensions (w x h x d) 35 x 94 x 113 mm 35 x 94 x 121 mm 35 x 94 x 125 mm 35 x 94 x 124 mm (incl. connector) (incl. connector) (incl. connector) (incl. connector) K Watt * Type No. K K K K Connector N female N male 7-16 female 7-16 male MHz VSWR MHz < 1.08 VSWR MHz < 1.15 VSWR MHz < 1.20 Indoor Approx. 0.8 kg 80 x 95 x 145 mm Dimensions (w x h x d) 67 x 90 x 130 mm 67 x 90 x 138 mm 67 x 90 x 134 mm 67 x 90 x 133 mm (incl. connector) (incl. connector) (incl. connector) (incl. connector) K Watt * Type No. K K K Connector N female N male 7-16 female MHz VSWR MHz < 1.08 Indoor Approx. 2.4 kg 130 x 195 x 180 mm Dimensions (w x h x d) 114 x 153 x 156 mm 114 x 161 x 156 mm 114 x 170 x 156 mm (including connector) (including connector) (including connector) * Rated power at 40 C ambient temperature. The max. power rating increases or decreases with falling or rising ambient temperature. K / i Subject to alteration. Note: The 50-Ohm load, type , should be used if intermodulation requirements are of high priority. K , K , K , K , K , Page 2 of 2 K , K , K , K , K , K KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. P.O. Box Rosenheim. Germany. Phone Fax
3 Ringleitung (180 Hybrid) 68 87,5 MHz / MHz / MHz Die Ringleitung kann man verwenden: als entkoppelten Verteiler zur Leistungsaufteilung im Verhältnis 1:1, zum entkoppelten Zusammenschalten von zwei Sendern mit beliebig kleinem Frequenzabstand (Verlust: 3 db), zum entkoppelten Zusammenschalten von zwei Empfängern mit beliebig kleinem Frequenzabstand, zum entkoppelten Zusammenschalten von zwei Sende-/Empfangsgeräten, deren integrierte Duplexweichen im gleichen Frequenzbereich liegen, als Komponente zum Aufbau von Weichen. 1 2 K K K Funktion: Die Ringleitung besitzt vier Anschlüsse, von denen je zwei voneinander entkoppelt sind. Eine z. B. in Anschluss 1 eintretende Wirkleistung teilt sich auf die Anschlüsse 2 und 4 auf. Anschluss 3 ist entkoppelt und bleibt leistungsfrei, wenn die Anschlüsse 2 und 4 ideal angepasst abgeschlossen sind. In der Praxis ist am Anschluss 3 ein Absorber geeigneter Leistung vorzusehen, entsprechend den Fehlanpassungen an den Anschlüssen 2 und 4. Die entkoppelte Zusammenschaltung kann wahlweise über die Anschlüsse 1 und 3 bzw. 2 und 4 erfolgen. 1 λ/4 2 λ/4 3 3/4λ λ/4 4 Technische Daten Typ-Nr. K K K /b Änderungen vorbehalten. Frequenzbereich 68 87,5 MHz MHz MHz Dämpfung 1 2 bzw ,2 ±0,4 db 3 ±0,4 db 3 ±0,4 db Dämpfung 1 3 bzw. 2 4 Siehe Diagramme auf der Seite 2 VSWR* < 1,3 < 1,2 < 1,2 Impedanz 50 Ω Eingangsleistung < 100 W pro Eingang Anschluss N-Buchse Material Gehäuse: Aluminium Montage Über 2 Schrauben (M 4) Gewicht 650 g 550 g 500 g Verpackungsmaße 230 mm x 35 mm x 130 mm Abmessungen (B x H x T) 225 mm x 32 mm x 117 mm inkl. Anschlüsse * VSWR, gemessen an einem beliebigen Anschluss (die übrigen Anschlüsse sind dabei mit 50 Ω abgeschlossen) K , K , K Seite 1 von 4 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. Postfach D Rosenheim. Deutschland. Telefon ( ) Fax ( )
4 Ringleitung (180 Hybrid) Typische Dämpfungskurven K K Dämpfung 1 2 / db Dämpfung 1 4 / db 2,5 3,0 3,5 Typischer Dämpfungsverlauf 1 2 und 1 4 als Funktion der Frequenz Dämpfung 1 2 / db Dämpfung 1 4 / db 2,5 3,0 3,5 Typischer Dämpfungsverlauf 1 2 und 1 4 als Funktion der Frequenz ,5 Frequenz/MHz K Dämpfung 1 3 oder 2 4 als Funktion der Frequenz Frequenz/MHz K Dämpfung 1 3 oder 2 4 als Funktion der Frequenz Dämpfung 1 3 / db Dämpfung 2 4 / db Dämpfung 1 3 / db Dämpfung 2 4 / db typischer Dämpfungsverlauf garantierte Werte Frequenz/MHz Frequenz/MHz typischer Dämpfungsverlauf garantierte Werte 180 K Dämpfung 1 2 / db Dämpfung 1 4 / db 2,5 3,0 3,5 Typischer Dämpfungsverlauf 1 2 und 1 4 als Funktion der Frequenz Frequenz/MHz K Dämpfung 1 3 oder 2 4 als Funktion der Frequenz Dämpfung 1 3 / db Dämpfung 2 4 / db typischer Dämpfungsverlauf garantierte Werte Frequenz/MHz Die übrigen Anschlüsse sind dabei mit 50 Ω abgeschlossen. K , K , K Seite 2 von 4 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. Postfach D Rosenheim. Deutschland. Telefon ( ) Fax ( )
5 Hybrid Ring Junction (180 Hybrid) MHz / MHz / MHz The hybrid ring junction can be used: as a power splitter with a ratio of 1:1, for the decoupled combining of two transmitters with arbitrarily low frequency spacing (at 3 db loss), for the decoupled combining of two receivers with arbitrarily low frequency spacing, for the decoupled combining of two transmitter/ receiver units, whose integrated duplexers are within the same frequency range, as component to form combiners. 1 2 K K K Description: The hybrid ring junction has four ports, two of which are decoupled from each other. For example effective power entering into port 1 is distributed into ports 2 and 4, port 3 is decoupled and without power if ports 2 and 4 are ideally matched. In practice an absorber of suitable power at port 3 is to be planned for according to the mismatch of ports 2 and 4. Decoupled combining can be made via port 1 and 3 or 2 and 4. λ/4 2 λ/ /4λ λ/4 4 Technical Data Type No. K K K ,5 MHz MHz MHz Attentuation 1 2 bzw ±0.4 db 3 ±0.4 db 3 ±0.4 db Attentuation 1 3 bzw. 2 4 See diagrams, page 4 VSWR* < 1.3 < 1.2 < 1.2 Impedance 50 Ω Input power < 100 W per Input Connector N female Material Housing: Aluminum Installation With 2 screws (M 4) 650 g 550 g 500 g 230 mm x 35 mm x 130 mm Dimensions (w x h x d) 225 mm x 32 mm x 117 mm with connectors * VSWR: measured at any input (the remaining ports are terminated with 50-Ω loads) K , K , K Page 3 of 4 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. PO Box D Rosenheim. Germany. Telephone Fax
6 Hybrid Ring Junction (180 Hybrid) Typical Attentuation Curves K K Attentuation 1 2 / db Attentuation 1 4 / db Typical attentuation 1 2 and 1 4 vs frequency Attentuation 1 2 / db Attentuation 1 4 / db Typical attentuation 1 2 and 1 4 vs frequency K Frequency/MHz Attentuation 1 3 or 2 4 vs frequency K Frequency/MHz Attentuation 1 3 or 2 4 vs frequency Attentuation 1 3 / db Attentuation 2 4 / db Attenuation 1 3 / db Attenuation 2 4 / db typical attentuation guaranteed values Frequency/MHz Frequency/MHz typical attentuation guaranteed values 180 K Typical attentuation 1 2 and 1 4 vs frequency Attentuation 1 2 / db Attentuation 1 4 / db Frequency/MHz K Attentuation 1 3 or 2 4 vs frequency Attentuation 1 3 / db Attentuation 2 4 / db typical attentuation guaranteed values Frequency/MHz /b Subject to alteration. The remaining ports are terminated with 50 Ω loads. K , K , K Page 4 of 4 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. PO Box D Rosenheim. Germany. Telephone Fax
7 Zirkulator MHz Den Zirkulator kann man verwenden: zur Erhöhung der Koppeldämpfung zwischen Sendern, um Intermodulationsprodukte zu vermeiden, zur Vermeidung von Rückwirkungen bei Verstärkern. 3 Funktion: Zirkulatoren sind nichtreziproke Bauelemente mit geringer Durchlassdämpfung in Senderichtung (1 2) und hoher Sperrdämpfung entgegen der Senderichtung (2 1). Die Impedanz am Eingang (1) des Zirkulators ist konstant und unabhängig von der Impedanz nachfolgender Komponenten, da die am Ausgang (2) reflektierte Leistung zum Absorber (3) geleitet wird, der mit einem Absorber abgeschlossen werden muss Dimensionierung des Absorbers: Der Absorber am Anschluss (3) muss so dimensioniert sein, dass er die am Ausgang (2) maximal reflektierte Leistung aufnehmen kann. Vorsicht Bei der Montage des Zirkulators ist ein Mindestbstand von 10 mm von umgebenden Stahlteilen oder sonstigen ferromagnetischen Teilen einzuhalten! Technische Daten Typ-Nr /a Änderungen vorbehalten. Frequenzbereich MHz Durchlassdämpfung 1 2 < 0,5 db (typ. 0,3 db) Sperrdämpfung 2 1 > 50 db VSWR 1, 2, 3 < 1,22 Impedanz 50 Ω Eingangsleistung < 100 W Temperaturbereich C Anschlüsse N-Buchse Gewicht 635 g Verpackungsmaße 160 mm x 90 mm x 40 mm Abmessungen (B x H x T) 133 mm x 69 mm x 26 mm (inkl. Anschlüsse) KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. Postfach D Rosenheim. Deutschland. Telefon ( ) Fax ( )
8 Circulator MHz 3 The circulator can be used: to increase the coupling attenuation between transmitters, to reduce intermodulation products, to prevent adverse effects of unmatched load impedance on amplifier performance. Function: Circulators are nonreciprocal components with low insertion loss in the forward direction (1 2) and high attenuation in the reverse direction (2 1). The impedance at the input (1) of the circulator is constant and independent of the impedance of the components following, since the reflected power is passed to the absorber port (3) Caution When installing the circulator, a minimum distance of 10 mm from surrounding steel or other ferro-magnetic parts must be kept to. Technical Data Type No MHz Insertion loss 1 2 < 0.5 db (typ. 0.3 db) Isolation 2 1 > 50 db VSWR 1, 2, 3 < 1.22 Impedance 50 Ω Input power < 100 W Temperature range C Connectors N female Mounting With 2 screws (M3) 635 g 160 mm x 90 mm x 40 mm Dimensions (w x h x d) 96 mm x 50 mm x 26 mm (without connectors) /a Subject to alteration. KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. PO Box D Rosenheim. Germany. Telephone Fax
9 Hybrid-Sendekoppler MHz Der Hybrid-Sendekoppler ermöglicht das Zusammenschalten von zwei oder mehreren Sendern auf einen gemeinsamen Ausgang. Vorteile des Hybrid-Sendekopplers sind: beliebig kleiner Abstand der Sendefrequenzen, variable Sendefrequenzen (z. B. bei mehrkanaligen Sendeeinheiten), Frequenzänderungen ohne Aufwand, geringer Platzbedarf. Aufbau und Funktion: Der Hybrid-Sendekoppler besitzt zwei, drei, vier oder fünf Eingänge und einen Ausgang. Für die Zusammenschaltung der Sender wird entsprechend der Zahl der Eingänge entweder eine Ringleitung, ein Entkoppelter Verteiler als Hybrid oder Koppler verwendet. In jedem Sendezweig ist ein breitbandiger Doppelzirkulator eingefügt, wodurch eine sehr hohe Entkopplung erreicht wird. Dadurch werden Intermodulationsprodukte wirkungsvoll unterdrückt. Die Absorber sind für eine am Ausgang eventuell auftretende Totalreflexion dimensioniert Sonderausführung: Sonderausführungen sind auf Anfrage erhältlich: mit Einfachzirkulator statt Doppelzirkulator, falls eine geringere Entkopplung ausreichend ist, mit einem Bandpass-Filter am Ausgang Technische Daten Typ-Nr. Eingänge Durchlassdämpfung Abmessungen Eingangsleistung Verpackungsmaße 19 -Einschub pro Eingang Höhe Tiefe /a Änderungen vorbehalten < 3,9 db 1 HE* = 44 mm 300 mm 25 W 535 mm x 120 mm x 435 mm < 3,9 db 4 HE* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm < 6,3 db 4 HE* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm < 7,3 db 4 HE* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm < 8,3 db 4 HE* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm Frequenzbereich MHz Min. Frequenzabstand 0 MHz Koppeldämpfung > 70 db Impedanz 50 Ω VSWR < 1,2 Anschlüsse N-Buchse Farbe Frontplatte: Grau (RAL 7032) HE* = Höheneinheit , , , , Seite 1 von 4 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. Postfach D Rosenheim. Deutschland. Telefon ( ) Fax ( )
10 Hybrid-Sendekoppler MHz Ausgang Ausgang Hybrid Ringleitung ring junction Entkoppelter Decoupled power Verteiler splitter 1 : 3 Eingang 1 Eingang Eingang 1 Eingang 2 Eingang Ausgang Entkoppelter Decoupled power Verteiler splitter 1 : 4 Eingang 1 Eingang 2 Eingang 3 Eingang Seite 2 von , , , , KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. Postfach D Rosenheim. Deutschland. Telefon ( ) Fax ( )
11 Hybrid Transmitter Combiner MHz The hybrid transmitter combiner allows two or more transmitters to be combined to a common output. Special features: very small spacing of the transmitting frequencies, down to adjacent channel spacing, variable transmitter frequencies, small dimensions. Design: The hybrid transmitter combiner has two, three, four or five inputs and one output. For combining trans-mitters a hybrid ring junction a decoupled power splitter is used as hybrid or couplers depending on the number of inputs. In every transmitting path a wide band dual circulator is inserted, which causes very high isolation. This effectively suppresses intermodulation products. The absorbers are dimensioned for a possibly occurring total reflection at the output Custom versions: Custom versions are available on request: with single circulator instead of dual circulator, if lower isolation is sufficient, with a band-pass filter at the output Technical Data Type No. Inputs Insertion loss Dimensions Input power 19 drawer per input height plug-in depth < 3.9 db 1 hu* = 44 mm 300 mm 25 W 535 mm x 120 mm x 435 mm < 3.9 db 4 hu* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm < 6.3 db 4 hu* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm < 7.3 db 4 hu* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm < 8.3 db 4 hu* = 177 mm 350 mm 100 W 535 mm x 260 mm x 490 mm MHz Min. frequency spacing 0 MHz Isolation > 70 db Impedance 50 Ω VSWR < 1.2 Connectors N female Colour Front panel: Grey (RAL 7032) * hu = height unit , , , , Page 3 of 4 KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. PO Box D Rosenheim. Germany. Telephone Fax
12 Hybrid Transmitter Combiner MHz Output Output Hybrid ring junction Decoupled power splitter 1 : 3 Input 1 Input 2 Input 1 Input 2 Input Output Decoupled power splitter 1 : 4 Input 1 Input 2 Input 3 Input /a Subject to alteration. Page 4 of , , , , KATHREIN-Werke KG. Anton-Kathrein-Straße 1 3. PO Box D Rosenheim. Germany. Telephone Fax
50-Ohm Load MHz W
50-Ohm Load 0... 4000 MHz 0.5... 100 W Standard 50-Ohm terminations for small and medium power Suitable for terminating open ports on RF equipment for indoor and /or outdoor applications 0.5 Watt * Type
Mehr50-Ohm Load MHz W
50-Ohm Load 0... 4000 MHz 0.5... 100 W Standard 50-Ohm terminations for small and medium power Suitable for terminating open ports on RF equipment for indoor and /or outdoor applications 0.5 Watt * Type
Mehr50-Ohm Load MHz W
50-Ohm Load 0... 4000 MHz 0.5... 100 W Standard 50-Ohm terminations for small and medium power Suitable for terminating open ports on RF equipment for indoor and /or outdoor applications 0.5 Watt * Type
MehrSPINNER MOBILE COMMUNICATION
KOAXIALE VERTEILER & RICHTKOPPLER COAXIAL SPLITTERS & COUPLERS SPINNER bietet seinen Kunden extrem breitbandige Komponenten, die eine gemeinsame Nutzung eines Verteilersystems für alle Mobilfunkanwendungen
MehrBetriebsarten-Umschalter Common mode / Differential mode switch
Betriebsarten-Umschalter Common mode / Differential mode switch Beschreibung: Der Betriebsarten-Umschalter CMDM 87 erweitert die Messmöglichkeiten zweier V-Netznachbildungen um die einer T- und Delta-Netznachbildung.
MehrTransmit Combiners. ANTENNENTECHNIK Bad Blankenburg AG
09/2004 H SENDEWEICHEN TRANSMIT COMBINERS Typenübersicht Product List Sendeweichen Transmit Combiners D 0.1 Typ: Beschreibung: TV-Signalleistung: Entkopplung: : Bestell-Nr.: Ausg.: Seite: Type: Description:
MehrSPINNER MOBILE COMMUNICATION
KOAXIALE ABSCHLUSSWIDERSTÄNDE & DÄMPFUNGSGLIEDER COAXIAL LOADS & ATTENUATORS Abschlusswiderstände übernehmen häufig die Funktion einer Antenne während der Test- oder Einmessphase einer Mobilfunk-Basisstation.
MehrSpezifikation für Freigabe / specification for release
74272722 STAR-FIX LFS mit Sicherheitsverschluß STAR-FIX LFS with Safety Lock DATUM / DATE : 2010-10-07 a 31,0 typ. mm b 35,1 typ. mm c 28,0 typ. mm für Kabeldurchmesser / for cable diameter Ø 8,5-12,5
MehrISN Impedanz Stabilisierungs Netzwerk für PLC Impedance Stabilization Network for PLC
ISN 561-1 Impedanz Stabilisierungs Netzwerk für PLC Impedance Stabilization Network for PLC Beschreibung: ISN 561-1 ist ein Impedanzstabilisierungsnetzwerk (ISN) zur Messung der asymmetrischen Störspannung
MehrDelta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS
Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-LAN Installationsvarianten Das DELTA 2.4 W-LAN System kann in verschiedenen Varianten installiert werden:
MehrOverview thermostat/ temperature controller
Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:
MehrDual polarisierte Breitband-Hornantenne Dual polarized broadband horn antenna
Dual polarisierte Breitband-Hornantenne Dual polarized broadband horn antenna Beschreibung: Dual polarisierte Doppelsteg Breitbandantenne in Aluminiumausführung für Empfangs- und Sendeanwendungen. Die
MehrDelta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS
Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-Lan Installationsvarianten Das DELTA 2.4 W-Lan System kann in verschiedenen Varianten installiert werden:
MehrSWC SPANNLAGER UND GEHÄUSE SWC RADIAL INSERT BALL BEARINGS AND HOUSING
SWC SPANNLAGER UND GEHÄUSE SWC RADIAL INSERT BALL BEARINGS AND HOUSING SWC bietet Gehäuseeinheiten bestehend aus einem Spannlager und wahlweise Stehgehäuse (UCP), Zweiloch-Flansch-Gehäuse (UCFL) oder Vierloch-Flansch-Gehäuse
MehrBreitband Hochgewinn Horn Antenne BBHA 9120 J Broadband High Gain Horn Antenna BBHA 9120 J
Breitband Hochgewinn Horn Antenne BBHA 9120 J Broadband High Gain Horn BBHA 9120 J Beschreibung: Die Breitband Hornantenne BBHA 9120 J ist eine linear polarisierte Hochgewinnantenne für den Frequenzbereich
MehrLow Profile Antenne Low Profile Antenna. MCA 1890 S Erz-Nr. / Ord. code Datenblatt / Datasheet CELLULAR
Low Profile Antenne Low Profile Antenna CELLULAR Passive Sende-/Empfangsantenne für die Frequenzbereiche GSM 850, GSM 900, GSM 1800, GSM 1900 und UMTS geringe Bauhöhe ca. 30 mm Abdeckung europäischer und
MehrS-P-Filter MHz
S-P-Filter as S-P-Filter (Stop-Pass-Filter) wird verwendet zur ämpfung einer Störfrequenz, die extrem nahe an einer Nutz frequenz liegt. Man kann es einsetzen: im Sendepfad zur Unterdrückung von Rauschseitenbändern
MehrSignal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen
LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL Sender/Empfänger mit Outdoor-Box Merkmale LWL-SBR, Übertragungsweiten bis zu 1500 m Wandlung üblicher Rechtecksignale
MehrSPINNER MOBILE COMMUNICATION
Der ständig wachsende Bedarf an Frequenzbändern in der Telekommunikation führt zu immer enger nebeneinander liegenden Sende- und Empfangsfrequenzen und damit vermehrt zu unerwünschten gegenseitigen Beeinflussungen
MehrTemperaturbereich / Temperature range C / F Schutzklasse / Protection class IP66 (acc. IEC 60529) GPS
Low Profile Antenne Low Profile Antenna GPS / CELLULAR GPS 18 LP/S/ 92 62- Empfangsantenne für GPS-Satellitensignale zur Verarbeitung in Navigationssystemen, Flottenmanagementsysteme, Verkehrsführungssysteme
MehrGestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna
Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna Beschreibung: Die STLP 9129 ist eine gestockte Log.-Per.- Breitband Antenne für Störfestigkeitsprüfungen im Frequenzbereich von
MehrZehnder ComfoWell 220
Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for
MehrDatenblatt Datasheet. Low Profile Antenne Low Profile Antenna GPS LP/P/ GPS / CELLULAR. Änderungen vorbehalten / Subject to alterations
Low Profile Antenne Low Profile Antenna GPS / CELLULAR Empfangsantenne für GPS-Satellitensignale zur Verarbeitung in Navigationssystemen, Flottenmanagementsysteme, Verkehrsführungssysteme und Fahrzeugortung.
MehrStahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting
Stahlgitterwiderstandselemente Steel Grid Resistor lements 500 W für inbau 500 W for fitting Stahlgitterwiderstandselemente RSW RSW 54 500 W für inbau Steel Grid Resistor lements RSW to RSW 54 500 W for
MehrKopplungs- und Entkopplungs-Netzwerk Coupling Decoupling Network. Specifications: Frequenzbereich: MHz Frequency range: Gleichtaktimpedanz:
Kopplungs- und Entkopplungs-Netzwerk Coupling Decoupling Network Beschreibung: Das CDN AF2 ist ein Teil der CDN Serie von Kopplungs- Entkopplungs- Netzwerken zur leitungsgeführten Immunitätsmessung an
MehrÄnderungen vorbehalten / Subject to alterations. Technische Daten / Technical data
Low Profile Antenne Low Profile Antenna GPS / CELLULAR Empfangsantenne für GPS-Satellitensignale zur Verarbeitung in Navigationssystemen, Flottenmanagementsysteme, Verkehrsführungssysteme und Fahrzeugortung.
MehrBandpass-Filter MHz
andpass-filter Das andpass-filter eignet sich als Empfangs- oder als Sendefilter für einen oder mehrere Empfänger oder Sender. Man kann es einsetzen: zur Verbesserung der Eingangsselektion von Empfängern
MehrAktivelektronik VP 150
Leistungsmerkmale der VP 150 Die VP 150 ist eine Einplatinenlösung, die aufgrund des Platinendesigns für den Einsatz als Subwoofer Aktiv-Modul gedacht ist. Verstärkerelektronik inkl. Aktivweiche zum Betrieb
MehrMehrbereichsweiche 68 87,5 MHz / MHz / MHz
68 87,5 MHz / / Die ermöglicht die Zusammenschaltung von mehreren Sendern bzw. Empfängern unterschiedlicher Frequenzbereiche auf einen gemeinsamen Ausgang. Man kann sie einsetzen: zur Zusammenschaltung
MehrZehnder ComfoWell 320
Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with locking slides for
MehrSnap-in switch for switches PSE, MSM and MCS 30
Product manual Snap-in switch for switches PSE, MSM and MCS 30 CONTENTS 1. PRODUCT DESCRIPTION 2. DATA AND DIMENSIONAL DRAWINGS 2.1. Technical Data 2.2. Dimensions of PSE with a Mounting Diameter 19 mm
MehrWandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply
Wandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply Beschreibung und technische Daten: Wandarm (IP-66) mit Montagebox und eingebautem Netzteil Passend für SANTEC
MehrBandpass-Filter MHz
andpass-filter 3 7 MHz Das andpass-filter eignet sich als Empfangsoder als Sendefilter für einen oder mehrere Empfangs- oder Sendekanäle. Man kann es einsetzen: zur Verbesserung der Eingangsselektion von
MehrRQ LR24. SK - VA - L
System RQ30 Rundtaster mit Schnellverschraubung round pushbutton with quick screw connection Merkmale Features geringer Hub 1,0 mm geringe Bauhöhe ca. 36 mm inkl. homogene Randausleuchtung durch LEDs Metallkragen
MehrLow Profile Antenna. GLONASS 1890 LP/S/FAKRA 3.0 Erz-Nr. / Ord. code 602 434-001. Datenblatt / Datasheet GLONASS / GPS / CELLULAR
Low Profile Antenna GLONASS / GPS / CELLULAR GLONASS 18 LP/S/FAKRA 3. 62 434-1 Kombinationsantenne für Satellitenempfang (GLONASS und GPS) für Telematiklösungen (z.b. Flottenmanagement, Fahrzeugortung
Mehr2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters
Application and performance characteristics Typically used to comply with EMC emission standards Reduce conducted emissions over the frequency range 150 khz to 30 MHz Suitable for Industrial, Railway,
Mehra) Name and draw three typical input signals used in control technique.
12 minutes Page 1 LAST NAME FIRST NAME MATRIKEL-NO. Problem 1 (2 points each) a) Name and draw three typical input signals used in control technique. b) What is a weight function? c) Define the eigen value
MehrProportional Magnetventil BFW PROPORTIONAL MAGNETVENTILE BFW. Proportional Solenoid Valve BFW. Technische Daten l Technical Data
Proportional Magnetventil BFW Erhältlich in CETOP und CETOP Durchflussmenge CETOP :, oder 7 l/min Durchflussmenge CETOP :, 7 oder l/min Inkl. Befestigungsschrauben und Ventilstecker Grundplatten zu den
MehrAttenuator and Distribution System Zehnder ComfoWell 220
Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for
MehrRUNDFUNK KOMPONENTEN UND SYSTEME BROADCAST COMPONENTS AND SYSTEMS
RUNDFUNK KOMPONENTEN UND SYSTEME BROADCAST COMPONENTS AND SYSTEMS INHALTSVERZEICHNIS CONTENTS Company Profile..............................................................................................
MehrKopplungs- und Entkopplungs-Netzwerk Coupling Decoupling Network
Kopplungs- und Entkopplungs-Netzwerk Coupling Decoupling Network Beschreibung: Das CDN M3PE 32A ist ein Teil der CDN Serie von Kopplungs- und Entkopplungs-Netzwerken zur leitungsgeführten Immunitätsmessung
MehrDatenblatt. P-series PDU 2.5/4/4AN
Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means
MehrSWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS
SWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS SWC bietet sowohl offene als auch abgedichtete Pendelrollenlager in verschiedenen Ausführungen an: Offene Ausführungen: o Zylindrische Bohrung mit Radialluft
MehrBandpass-Filter 68 87,5 MHz
andpass-filter 7,5 MHz Das andpass-filter eignet sich als Empfangs- oder als Sendefilter für einen Empfänger oder Sender. Man kann es einsetzen: zur Verbesserung der Eingangsselektion von Empfängern oder
MehrOptische Verteiltechnik Optical Distribution Technology. premium-line. Optischer LNB Optical LNB
Optische Verteiltechnik Optical Distribution Technology Optischer LNB Optical LNB das Signal eines Satelliten wird in ein optisches Signal gewandelt optischer Ausgang in 30 nm-technologie 2V-Netzteil im
MehrZehnder CLD. Housing for walls, floors and ceilings
Benefits Suitable for wall, floor or ceiling installation Air volumes up to a maximum of 30 m 2 /h (ComfoTube 75) and 45 m 2 /h (ComfoTube 90) Can be installed in timber or solid constructions Extract
MehrHG BK-Hausanschlussverstärker CATV-Home Distribution Amplifier. Bedienungsanleitung/ Operating manual V5 KDG C(4.3)
BK-Hausanschlussverstärker CATV-Home Distribution Amplifier HG 40125 Polytron-Vertrieb GmbH Langwiesenweg 64-71 75323 Bad Wildbad, Germany KDG C(4.3) Bedienungsanleitung/ Operating manual 0901759 V5 Montage-
MehrTechnische Daten / Technisches Merkblatt (nach pren ) ECHOGRAPH 1016B (Best.-Nr )
DISPLAY type of display CRT D10 size of display 72 x 60 grid 68 x 55 scale division coarse:10 fold ( and ) fine: 5 fold ( and ) acceleration voltage 10 kv MEASURING RANGES measuring length 0-100 mm; 0-500
MehrProduktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten.
Produktdatenblatt Artikel Nr.: 110010 Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W Technische Daten Charakteristik Material Farbe Aluminium Druckguss Weiß-matt Optik im Lieferumfang
MehrSignal Processing Präzisions-Interpolator / Splitter Wandlung von SinCos-Gebersignale in TTL- und HTL-Ausgangssignale
Präzisions-Interpolator / Splitter Wandlung von SinCos-Gebersignale in TTL- und HTL-Ausgangssignale Merkmale Wandlung von SinCos-Signalen in TTL- und HTL-Signale Zusätzliche Interpolation der Signale (Vervielfachung
MehrNNBM 8126-A 890. Bordnetznachbildung für Flugzeuge NNBM 8126-A 890 Single path airborne equipment LISN NNBM 8126-A 890
Bordnetznachbildung für Flugzeuge NNBM 8126-A 890 Single path airborne equipment LISN NNBM 8126-A 890 Beschreibung: Die unsymmetrische, einpolige Bordnetznachbildung NNBM 8126-A 890 wird hauptsächlich
MehrProduktdatenblatt. Artikel Nr.: Deckeneinbauring, Weiß, 12V AC/DC, 1x max. 50,00 W. Technische Daten. Charakteristik.
Produktdatenblatt Artikel Nr.: 126070 Deckeneinbauring, Weiß, 12V AC/DC, 1x max. 50,00 W Technische Daten Charakteristik Material Farbe Aluminium Druckguss Weiß Optik im Lieferumfang Elektrische Daten
MehrS-P-ilter Typische ämpfungskurven bstimmbeispiele: ämpfung/d , f o +, +1 +1, requenz/mhz ämpfung/d , -1 -, f o +, re
S-P-ilter as S-P-ilter (Stop-Pass-ilter) wird zur ämpfung einer Störfrequenz, die extrem nahe an einer Nutzfrequenz liegt, verwendet. Man kann es einsetzen: im Sendepfad zur Unterdrückung von Rauschseitenbändern
MehrTECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS
TECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS 113 ÖLKÜHLER - AIR/OIL COOLERS ALUMINIUM ALUMINUM Typ Models Öldurchfluss Oil flow capacity Lüfter Fan Kühlleistung Performance (40 C) Arbeits-- druck Pressure
MehrMultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!
MultiPortSwitch VGA Umschalter Version 1.0 As of April 19 th 2004 Subject to change! Document version: Version Date Name Comment 1.00 29.03.2004 J. Klein Compiled Distributed by: idata industrielle Datensysteme
MehrPROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module
LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.
MehrNewest Generation of the BS2 Corrosion/Warning and Measurement System
Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing
MehrD12 Tel. +49 (0)7081 / Fax +49 (0)7081 / Quattro LNBs. Ausgänge bei Teilnehmern. Outlets to receivers
A Kopfstellen Headends Green Line Multischalter 13 Eingänge Green Line Multiswitches 13 inputs B Modulatoren Modulators Quattro LNBs PAS 28113 N C Optische Geräte Optical devices PSG 1308 C Kaskaden-Multischalter
MehrVHBA :1 100 W-Balun mit Bikonus-Elementen BBA 9106 VHBA :1 100 W-Balun with Biconical Elements BBA 9106
VHBA 9123 4:1 100 W-Balun mit Bikonus-Elementen BBA 9106 VHBA 9123 4:1 100 W-Balun with Biconical Elements BBA 9106 Beschreibung: Der Antennenhalter / Balun VHBA 9123 mit verlustarmem Leitungsübertrager
MehrSampling Rate / Sample rate. Modulation (gem. DVB-Standard) Modulation (DVB standard) 16 QAM 256 QAM QPSK, 16 QAM, 64 QAM
-Modulatoren modulators 1x in oder DVB-T Modulator zur Umsetzung eines -Signals in einen Kanal (QAM) oder in einen DVB-T Kanal (COFDM). Die Ausgangsmodulation kann über das Menü eingestellt werden. Der
MehrHDTV cinematic feeling with all HDMI 2.0 features, improved haptics and design packaging
HDTV cinematic feeling with all HDMI 2.0 features, improved haptics and design packaging The Cinema Series from PureLink sets an example with sophisticated and future-proof technology when it comes to
MehrDeceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H
Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H 12070 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Material: - Aluminium and steel Applications:
MehrEL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL
EL-21SY 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 2 4.1 Front Panel Diagram 2 4.2 Rear
MehrSCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003
177 136 3/8" Anwendung Application Die magnetische Feldspule FESP 5133- The magnetic field monitoring loop 7/41 dient zur Bestimmung der was designed to Magnetfeldstärke bis max. ca. 200 khz. Sie ist mit
MehrKühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00
Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00 Inhalt S./P. 1. Beschreibung / Description...
MehrEinsatzbereiche. Applications
SOLAMAGI 2800/4000 Licht-Wärme SOLAMAGI 2800/4000 light-heat Die individuell gestaltbare Licht-Wärme-Kombination ist vielseitig einsetzbar und lässt in den Bereichen Wärme, Licht und Komfort keine Wünsche
MehrM12 Verteilerinsel / M12 Splitter box
Serie / Series VER 4-1 Technische Daten Technical data Norm Kabel ohne mit Standard Cable without with Polzahl Kontaktanforderung IEC 947-5-2 4/5 No. of contacts Contact configuration IEC 947-5-2 4/5 Verschmutzungsgrad
MehrFerritbauteile Soft Ferrite Components. Toroidal cores. Ringkerne
Ferritbauteile Soft Ferrite Components aus Ferrit werden in manchen Schaltungen der Hochfrequenz- und Nachrichtentechnik als Impulsübertrager, Breitband- und Anpassungsübertrager, Drosseln und HF-Spulen
MehrMicro-RF. 294 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) ,
Micro-RF components can be used up to 6 GHz in various wireless applications, e. g. cellular and cordless phones, Bluetooth and wireless LAN applications, PDAs (Personal Digital Assistants) or wireless
MehrConnecting bend 90 connecting bend parts that serve as a connection between the hydraulic separator and the compact manifold.
Technical data sheet MultiFlow Expert Components of the MultiFlow Expert - hydraulic separator - connecting bends - multiple compact manifolds [D] Manufacturer certification Description MultiFlow Expert
MehrSchalten einer kapazitiven Last mit einem Transistor
. Schalten einer kapazitiven Last mit einem Transistor In allgemeinen technischen Anwendungen ist das Schalten einer kapazitiven Last eher von untergeordneter Bedeutung. In Rechnersystemen (Computernetzwerken)
MehrDatenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs
2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with
MehrDeceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H
Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H 6030 Deceleration Technology ONLINE CALCULATION AND 2D / 3D CAD DOWNLOAD M m L F Benefits Material: - Aluminium and steel Applications:
MehrC 146 EMV Gehäuse/EMC Housings
146 EMV Gehäuse/EM Housings Für Serien 146 E 6-24 pol 146 D 4-64 pol 146 M 2-7 Module 146 HSE 6 pol For series 146 E 6-24 contacts 146 D 4-64 contacts 146 M 2-7 Module 146 HSE 6 contacts mphenol 151 146
Mehrasled3000 Dimmbarer High Power LED-Treiber
asled3000 Dimmbarer High Power LED-Treiber A1.20 01/07 Leistungsmerkmale asled3000 ist ein dimmbares Treibermodul zur Versorgung von Hochleistungs-LEDs beliebiger Lichtfarbe. Es kann bis zu 6 LEDs mit
Mehrmodular case series MGS-superior Gehäuse Serie MGS-superior GEHÄUSE KATALOG
Gehäuse Serie Die flexible Gehäuseserie als 9-Zoll- Volleinschub oder Desktop-Ausführung. modular case series The flexible case series as a 9-inch plug-in box or desktop version. Diese neu entwickelte
MehrMini OEM Sender / Mini OEM Transmitter
Mini OEM Sender / Mini OEM Transmitter Kanalwahlschalter Schaltkanal 6V Ausführung auf Anfrage Channel selector Switching channel 6V version on request 5.8GHz Bereich / range 7558 004510 SupraLink Mini
MehrCertificate of conformity Generating unit, NS-protection
Applicant: Product: Certificate of conformity Generating unit, NS-protection Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with
MehrKopplungs- und Entkopplungs-Netzwerk Coupling Decoupling Network
Kopplungs- und Entkopplungs-Netzwerk Coupling Decoupling Network Beschreibung: Das CDN M4 32A ist ein Teil der CDN Serie von Kopplungs- und Entkopplungs-Netzwerken zur leitungsgeführten Immunitätsmessung
MehrTube Analyzer LogViewer 2.3
Tube Analyzer LogViewer 2.3 User Manual Stand: 25.9.2015 Seite 1 von 11 Name Company Date Designed by WKS 28.02.2013 1 st Checker 2 nd Checker Version history Version Author Changes Date 1.0 Created 19.06.2015
MehrTechnical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung
Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung 4...7 V 5 V *) Rated Current Nennstrom < 50 ma Sound Output [SPL]at 10 cm Lautstärke[Schalldruckpegel]
MehrPSG 512 A. Stromversorgung / Power supply. Betriebstemperatur / Operation temperature C
Multischalter Green Line A Verstärker / Amplifier B Kopfstellen / Headends C Optische Komponenten Multischalter Green Line 5 IN Endmultischalter zur Verteilung von 4 SAT-ZF- (z.b. ASTRA) und terrestrischen
Mehr19 Network Cabinet Modular, Unequipped Frame for modular upgrading or use as open rack
19 Network Cabinet Modular, Unequipped Frame for modular upgrading or use as open rack page 1 of 6 Art.-No. 692515U.. 692447U unequipped basic frame for modular upgrading depth-adjustable 19 profiles with
MehrFerritmaterial F2a. µ i +/- 25% 350. tan δ / µ i α F +20 C +70 C 10-6 K -1-0,5 ρ Ωm 10 5 T C C 340. B S mt 500. H A/m
3. November 207 Seite /6 Datenblatt Ferritmaterial Ferrittyp/Ferrite type Ferritmaterial Werkstoffnummer zur Identifikation Code number for ferrite grad Anfangspermeabilität initial permeability Bezogener
MehrAttenuator and Distribution System Zehnder ComfoWell 320
Attenuator and Distribution System Zehnder ComfoWell 32 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy
MehrGEHÄUSE KATALOG. COF Combiflex Die Combiflex-Gehäuse bestehen aus 2 Strangpressprofilen,
4 - Combiflex COF Combiflex Die Combiflex-Gehäuse bestehen aus 2 Strangpressprofilen, die sich beliebig miteinander kombinieren lassen, und zwei Abschlussdeckeln, die mit vier M3 Schrauben mit den Profilen
MehrSCHWARZBECK MESS - ELEKTRONIK
Double Ridged Broadband Horn BBHA 9120 F Technische Daten: BBHA 9120 F Specifications: Linear polarisierte Doppelsteg Breitband Hornantenne in Aluminiumausführung für Empfangs- und Sendeanwendungen. Für
MehrLukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen
Technical Report No. 028-71 30 95685-350 of 22.02.2017 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen
MehrHochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung
Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung High Voltage measurement device HV3000 AC / DC / Impulse H+H High Voltage Technology www.hundh-mk.com Hochspannungsmessgerät typ HV3000
Mehrmax. Flügelgewicht: 140 kg max. Flügelgewicht: 200 kg max. Flügelbreite: mm max. Flügelbreite: mm
JUMBO Allgemeine und technische Hinweise: JUMBO - Universalbeschläge haben ihren besonderen Einsatzbereich bei stärkeren Glasdicken und großen Flügelabmessungen gefunden. Dieser Beschlag ist geeignet für
MehrSPINNER MOBILE COMMUNICATION
DC-Einspeisungen werden verwendet, um in Mobilfunksendeanlagen Gleichstrom oder niederfrequente Steuersignale in den Innenleiter eines koaxialen Kabels einzuspeisen. Gleichzeitig werden diese Einspeisungen
Mehr