1 Part No. Y-ConCable Y-ConCable for use with Y-Con series plugs, with 4 data and 2 power lines, with Y-Con series plugs, with 4 data lines, mit 4 Daten- und 2 Stromversorgungsleitungen, NICHT mit 4 Datenleitungen, NICHT PVC PVC max. 100,000 Bending Radius: 125mm multiple turns 35mm single turn - Bending Radius: min. 50mm single turn Grey 18 SPECIFICATIONS ARE FOR REFERENCE ONLY AND SUBJECT TO ALTERATION WITHOUT PRIOR NOTICE DIMENSIONS IN MILLIMETER
2 industrial cables Y-ConCable Y-ConCable with Y-Con series plugs, with 4 data and 2 power lines, suitable for CABLE CHAIN with Y-Con series plugs, with 8 data lines suitable for CABLE CHAIN mit 4 Daten- und 2 Stromversorgungsleitungen, mit 8 Datenleitungen, Bending Radius: 105mm multiple turns 35mm single turn Bending Radius: 68mm Info: not tested or approved for DriveCliq Info: nicht für DriveCliq qualifiziert und freigegeben Info: not tested or approved for DriveCliq Info: nicht für DriveCliq qualifiziert und freigegeben 19
3 industrial cables Part No. Y-ConCable AVAILABLE ON REQUEST for use with Y-Con series plugs, with 6 data and 2 power lines, suitable for CABLE CHAIN Y-ConCable for use with Y-Con series plugs, with 8 data and 2 power lines, suitable for CABLE CHAIN für den Einsatz mit Steckverbindern der Y-Con Serie, mit 6 Daten- und 2 Stromversorgungsleitungen, für den Einsatz mit Steckverbindern der Y-Con Serie, mit 8 Daten- und 2 Stromversorgungsleitungen, Bending Radius: 70mm multiple turns 20 SPECIFICATIONS ARE FOR REFERENCE ONLY AND SUBJECT TO ALTERATION WITHOUT PRIOR NOTICE DIMENSIONS IN MILLIMETER
4 cable specifications Cable Cable-1 (4+2) Cable-2 (4+0) Cable-3 (4+2) Cable-4 (8+0) Operating Voltage 30V AC 30V AC 30V AC 30V AC Betriebsspannung Conductor Resistance (Data) <90 Ohm / km (Data) <90 Ohm / km (Data) <135 Ohm / km (Data) <120 Ohm / km Leiterwiderstand wire 0.22mm 2 AWG 24/7 wire 0.22mm 2 AWG 24/7 wire 0.14mm 2 AWG 26/7 wire 0.14mm 2 AWG 26/7 (Power) < 55 Ohm / km (Power) < 62 Ohm / km wire 0.38mm 2 AWG 22/19 wire 0.34mm 2 AWG 22/7 Insulation Resistance >1 GOhm / km >1 GOhm / km >1 GOhm / km >150 MOhm / km Isolationswiderstand Dielectric Strength 500V / 50Hz for 1 min 500V / 50Hz for 1 min 500V / 50Hz for 1 min 700V / 50Hz for 1 min Prüfspannung Capacitance 50nF / km at 800Hz 50nF / km at 800Hz 50nF / km at 800Hz 48nF / km at 800Hz Betriebskapazität Characteristic Impedance 100 +/- 15 Ohm 100 +/- 15 Ohm 100 +/- 15 Ohm 100 +/- 15 Ohm Wellenwiderstand at 1Mhz to 100Mhz at 1Mhz to 100Mhz at 1Mhz to 100Mhz at 1Mhz to 100Mhz Near-end Crosstalk 100Mhz > 32dB / 100m 100Mhz > 32dB / 100m 100Mhz > 32dB / 100m 100Mhz > 32dB / 100m Nahnebensprechen Flame Resistance IEC IEC IEC UL-Style Flammbeständigkeit Cable Diameter 6.9mm (+0.1) 6.75mm (+0.15) 6.8mm (+0.2) 6.8mm (+0.2) Kabeldurchmesser Silicon Free Yes Yes Yes Yes Silikonfrei Halogen Free No No Yes Yes Halogenfrei CFC Free Yes Yes Yes Yes FCKW-frei Cable Cable-5 (USB) Cable-6 (IEEE) Cable-7 (ProfiNet) Cable-10 (8+2) Operating Voltage 30V AC 30V AC 30V AC 30V AC Betriebsspannung Conductor Resistance (Data) 210 Ohm / km (Data) 340 Ohm / km (Data) 60 Ohm / km (Data) 280 Ohm / km Leiterwiderstand wire 0.09mm 2 AWG 28/7 wire 0.06mm 2 AWG 30/7 wire 0.34mm 2 AWG 22/7 wire 0.14mm 2 AWG 26 (Power) 145 Ohm / km (Power) 150 Ohm / km wire 0.14mm 2 AWG 26/7 wire 0.25mm 2 AWG 23 Insulation Resistance >20 MOhm / km >20 MOhm / km >500 MOhm / km >150 MOhm / km Isolationswiderstand Dielectric Strength 1,000V / 50Hz for 1 min 500V / 50Hz for 1 min 2,000V / 50Hz for 1 min 1,000V / 50Hz for 1 min Prüfspannung Capacitance 63nF / km at 800Hz 38nF / km at 800Hz 53nF / km at 800Hz 48nF / km at 1KHz Betriebskapazität Characteristic Impedance 90 +/- 15 Ohm 110 Ohm 100 +/- 15 Ohm 100 +/- 15 Ohm Wellenwiderstand at 1Mhz to 100Mhz at 1Mhz to 100Mhz at 1Mhz to 100Mhz at 1Mhz to 100Mhz Near-end Crosstalk - 100Mhz > 52dB / 100m 100Mhz > 50dB / 100m 100Mhz > 35dB / 100m Nahnebensprechen Flame Resistance UL Style UL Style UL Style UL Style Flammbeständigkeit Cable Diameter 4.2mm (+0.2) 5.2mm (+0.2) 6.8mm (+0.2) 6.9mm (+0.1) Kabeldurchmesser Silicon Free Yes Yes Yes Yes Silikonfrei Halogen Free No No Yes Yes Halogenfrei CFC Free Yes Yes Yes Yes FCKW-frei 21
5 ProfiNet Building on the success of ProfiBus, the ProfiNet transmission standard is set to become one of the most important for industrial automation applications. The Y-Con ProfiNet connector employs piercing contacts, and the plug mating face conforms to the RJ45 standard. It can thereby be used with standard RJ45 jacks and is backwards compatible. Aufbauend auf dem Erfolg von ProfiBus ist der ProfiNet Übertragungsstandard dabei, einer der wichtigsten Verkabelungsstandards für Anwendungen der industriellen Automation zu werden. Der Y-Con ProfiNet Stecker verwendet Piercing-Kontakte. Das Steckgesicht ist identisch mit dem RJ45-Steckertyp. Somit ist er auch mit Standard RJ45-Buchsen anwendbar und abwärts kompatibel. Part No. Y-ConPlug-15 8(4) Y-ConCable-7 RJ45 Cat 5 plug for use in ProfiNet applications, with cable guide, shielding and cable crimp. 4 data contacts. Suitable for AWG22 cable with a lead 1.40mm RJ45 Cat 5 Kabelstecker für ProfiNet-Anwendungen mit Kabelführung, Schirmung und Kabelverschraubung. 4 Datenkontakte. Passend zu AWG22-Kabel mit Einzelader 1,40mm 100 Mbit, Cat 5e ES, digital signal cable for use with Y-ConPlug-15 in ProfiNet applications, with 4 data lines, 100 Mbps, Cat 5e ES, Kabel für digitale Signale, für den Einsatz mit Y-Con-Plug15 bei ProfiNet-Anwendung mit 4 Datenleitungen, NICHT Material: Plug Steckergehäuse PBT, UL94V-0 Material: Cable Guide PBT, UL94V-0 Kabelführung Bending Radius: 49mm multiple turns 21mm single turn Shield: Schirm Nickel plated brass Contact: Kontakt 30µ" Au over Ni Operating Temp.: -20 C ~ +120 C 27
HF13-Programm HF13 Programme
S. 221 HF13 plugs S. 222 HF13-Adapter HF13 adapters S. 223 HF13-Buchsen s 2 HF13 - Programm Die HF-Steckverbindungen der Serie 13/4 werden in Anlagen der Nachrichtentechnik (DIN 47 283 und DIN 47 284),
Mehr6 FME FME. 140 Telegärtner Web: Tel: +49-(0) / Fax: +49-(0) /
6 Contents 6.1 Straight Plug Crimp................ 143 6.2 Press-In Bulkhead Receptacle, male... 143 6.3 Straight Jack Crimp................ 143 6.4 Bulkhead Plug.................... 144 6.5 Adaptor........................
MehrSolder area 80µ Sn/50µ Ni
# page 30 Part No. Description Y-ConJack-11 8(8) Y-ConJack-21 8(8)+2 improved shielding, with or without 2 power contacts with PCB-locks. Y-ConJack-21-PP 8(8)+2 improved shielding, 2 power contacts and
MehrBNC - Programm BNC Programme
- Programm S. 215 Adapter Adapters S. 217 -Adapterleitungen adapter leads S. 218 Sicherheits-Adapter Safety adapters www.schuetzinger.de 213 - Programm Die HF-Steckverbindung der Serie ist die häufigste
Mehr4 UHF UHF. 122 Telegärtner Web: Tel: +49-(0) / Fax: +49-(0) /
4 Contents 4.1 Straight Plug..................... 125 4.2 Straight Plug Crimp................ 125 4.3 Angle Plug...................... 125 4.4 Angle Plug Crimp................. 126 4.5 Bulkhead Jack Crimp...............
Mehr1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid. Generic specification: IEC , IEC
ELCRIGID SN 39 225 E with tin soaked braid Seite 1 v 6 1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid 2 Specifications Generic specification: IEC 61196-1, IEC 60096-0-1
MehrD-Sub Dualport Steckverbinder D-Sub dualport connectors
D-Sub Dualport Steckverbinder D-Sub dualport connectors Bestellschlüssel Ordering code ALL DIMENSIONS IN MILLIMETERS - VALUES FOR INCHES IN BRACKETS - TECHNICAL DATA SUBJECT TO CHANGE 73 Technische Daten
MehrProfibus-Leitungen für feste Verlegung Profibus cable for static application
Profibus-Leitungen für feste Verlegung Profibus cable for static application Verwendung Diese Busleitung eignet sich zur Daten übertragung in PROFIBUS- Netzwerken. Die hier aufgeführten Typen finden An
MehrMeterangabe auf Knickschutztülle meter mark on strain relief. Packing. Oberfläche/ Modular Patch Cable F/UTP Cat.
Kabelaufbau LI2Y(ST)H 4x2xAWG26/7 Verpackung Rasthebelschutz latch protection 1:1 untol. Maße/ Unterl./doc. type 10 L 50 Meterangabe auf Knickschutztülle 1 Stück im PE-Beutel mit Etikett. Umverpackung:
MehrVOKA-LAN XLAN 350 VOKA-LAN XLAN 350 FTP-C 4PR AWG 24/1 FTP-C 4PR AWG 24/1. Datenkabel. Anwendung. Application. Aufbau.
Kategorie 6 FTP-C 4PR AWG 24/1 Data cable Category 6 FTP-C 4PR AWG 24/1 Anwendung Datenübertragungskabel mit Gesamtschirm im Frequenzbereich bis 350 MHz, guten Systemreserven und ausgezeichneter Schirmwirkung.
MehrOptik Konverter für Profibus Optical converter for Profibus
Lichtwellenleiter Koverter Optical fibres converters Optik Konverter für Profibus Optical converter for Profibus Technische Daten Technical data Versorgungsspannung: 5V DC Supply voltage: 5V DC Stromaufnahme:
MehrHigh Density D-Sub Crimp Connectors High Density D-Sub Crimp Steckverbinder
High Density D-Sub Crimp Connectors High Density D-Sub Crimp Steckverbinder Technical Data Technische Daten Mechanical Data Mechanische Daten Shell Gehäuse Insulator Isolierkörper Signal contacts Signalkontakte
MehrHigh shielded antenna cable / 3-fach geschirmtes Antennenkabel, Date: June 25, 2010 (3)
Product information SKB 395-xx High shielded antenna cable / 3-fach geschirmtes Antennenkabel, Date: June 25, 2010 (3) High shielded antenna cable / 3-fach geschirmtes Antennenkabel Impedance/Wellenwiderstand:
MehrMICRO MINIATURE & MINI CONNECTORS
MICRO MINIATURE & MINI CONNECTORS G e r m a n y - H o n g K o n g - Ta i w a n - T h e N e t h e r l a n d s - S o u t h A f r i c a - U S A QUALITÄT-DIENSTLEISTUNG-INNOVATION QUALITY - SERVICE - INNOVATION
MehrData sheet C6 A modul 2 port 180 M UP0
Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification termination unit with C6 A modul 180 certified to GHMT Cat.6 A re-embedded PVP component testing
Mehr336 Wannenstiftleisten RM 1,27mm, gerade/gewinkelt Box Headers, 1.27mm Pitch, Straight/Right-Angled
Technische Daten / Technical Data Isolierkörper Thermoplastischer Kunststoff, nach UL94 V-0 Insulator Thermoplastic, rated UL94 V-0 Kontaktmaterial Messing Contact Material Brass Kontaktoberfläche Vergoldet
MehrMeterangabe auf Knickschutztülle meter mark on strain relief. Packing. Gewicht/ weight [g] Oberfläche/ surface [mm²]
Kabelaufbau Li2YY 4x2xAWG24/7 Verpackung max. 5,6 7,8 1 Stück im PE-Beutel mit Etikett. Umverpackung: Karton (Außenmaße: 275 mm x 295 mm x 380 mm). Umverpackungsmenge differiert je nach Kabellänge. L 50
MehrFMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0)8684 18-0, info@rosenberger.de, www.rosenberger.com
The extremely small FMC connector series Flexible Microstrip Connectors are designed for PCB applications in the tightest spaces. Using bullets, equalization of radial and axial misalignments in board-to-board
MehrData sheet. E-DAT C6 2 port UPk pure white. Illustrations P/N I EAN Product specification. Page 1/
Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification raceway termination unit with one or two 8-pole RJ45 jack certified to GHMT Cat.6 12C-de-embedded
Mehr9 SSMB SSMB. 192 Telegärtner Web: Tel: +49-(0) / Fax: +49-(0) /
Contents.1 Straight Plug Crimp............... 15.2 Bulkhead Receptacle, male......... 15.3 Bulkhead Plug Crimp.............. 15.4 PCB Receptacle, male............. 16.5 Angle PCB Receptacle, male........
MehrCode for Special Contacts Nummernschlüssel für Sonderkontakte
Code for Special Nummernschlüssel für Sonderkontakte Ordering Code Bestellschlüssel Series Features Baureihen-Features FDX-Series FDX-Serie Coaxial contact for cable termination Inner conductor for solder
MehrODU AMC. Montageanleitung ODU AMC Abreiss-Kabelstecker. Montageanleitung. www.odu.de. Stecker
ODU AMC Abreiss-Kabelstecker Stecker Schirmhülse Crimphülse 1. Crimphülse und Schirmhülse über das Kabel schieben. Bei Verwen dung eines Metallbandes zur Schirmbefestigung auf der Schirmhülse wird die
MehrLeiter/conductor Isolierung/insulation
Quick Strip Seite 1 v 6 Verwendung: Geräteverbindungsleitung zur Übertragung von digitalen Signalen nach Profibus- Spezifikation use cable for transmission of digital signals. 1. Bauartkurzzeichen/code
MehrDatenblatt. P-series PDU 2.5/4/4AN
Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means
MehrPROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module
LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.
MehrLIYCY (französisch) LIYCY
(französisch) Beschreibung Nach DIN 47100/OZ Description According to DIN 47100/OZ Verwendung Als Anschluss- und Verbindungsleitung in der Steuer-, Regel-, Mess- und Signaltechnik sowie in der Datenverarbeitung
MehrIndustrial Connection System
Industrial Connection System ONIEEE SERIES PROFI ON SERIES W W W. Y A M A I C H I. E U 2011 Table of Contents Y-ConRJ45 system overview... inside cover IP67/68/69K protected components for Y-Con RJ45 Cover,
MehrSMC, 50 Ω. Features. Product Range
I I 11SMC, 50 Ω Interface Dimensions SMC, 50 Ω Code 39 REFERENCE PLANE Referenzebene REFERENCE PLANE Referenzebene L F G D F D B A E C H K H C E A B MALE Stecker FEMALE Kuppler G SMC, 50 Ω Male Stecker
MehrSubminiatur Rundsteckverbinder Serie 711 Subminiature circular connectors series 711. Kurzinformation Brief information Ü TI
Serie 11 11 Subminiatur undsteckverbinder Serie 11 Subminiature circular connectors series 11 Kurzinformation rief information 60 0 09 10 11 1 19 0 1 6 60 6 0 6 69 69 69 0 1 1 6 6 6 1 1 66 1 0 6 Kabelsteckverbinder
MehrTelegärtner Web: Tel: +49 (0) / Fax: +49 (0) /
223 13 13.1 Bulkhead Plug...228 13.2 Straight Receptacle, Male, for PCB...228 13.3 Angle Receptacle, Male, for PCB...228 13.4 Straight PCB Receptacle in SMT and Edge-Mount...229 13.5 Straight PCB Plug...229
MehrLichtwellenleiter POF* mit PE Mantel Optical fibre POF* mit PE Mantel
Lichtwellenleiter POF* mit PE Mantel Optical fibre POF* mit PE Mantel Technische Daten simplex Technical data simplex POF simplex 1 mm; 2,2 mm POF simplex 1 mm, 2,2 mm Faser fibre: PMMA 980/1000 Temperaturbereich:
MehrDatenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs
2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with
MehrIDC Ribbon Connectors Flachbandkabelsteckverbinder. Product Description Produktbeschreibung
IDC Ribbon Connectors Product Description Produktbeschreibung Advantages and Special Features Connector with IDC-contacts for termination of IDC Ribbon cables Available in sizes -way to 7-way With strain-relief
MehrM16 Steckverbinder IP 40 M16 connectors IP 40
R BF-C BF-B BF-A /8 M8 M-US M-D M-B Verteiler VL M-A M8 M RD0 RD M Bajonett M M IP M IP0 PP IP Bajonett SI IP M9 IP M9 IP0 PP IP MPP IP Bajonett SI IP SI IP0 TI Ü binder M Steckverbinder IP 0 M connectors
MehrM12 Automatisierungstechnik - Sonder - US-Kodierung M12 Automation Technology - Special - US-Coding
665 Sonder Sensor 815 866 M12 Automatisierungstechnik - Sonder - US-Kodierung M12 Automation Technology - Special - US-Coding Kabelsteckverbinder Schraubverriegelung nach DIN EN 61076-2-101 Schutzart IP67/IP68
Mehrengineered to connect y-con And STAndARD RJ45
engineered to connect y-con And STAndARD RJ45 industrial connector system connector solutions Y-Co Y-CONRJ45 IndustRIal system overview The Y-ConRJ45 connector system with or without EMI protection in
Mehrmiditech 4merge 4-fach MIDI Merger mit :
miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse
MehrM12 Verteilerinsel / M12 Splitter box
Serie / Series VER 4-1 Technische Daten Technical data Norm Kabel ohne mit Standard Cable without with Polzahl Kontaktanforderung IEC 947-5-2 4/5 No. of contacts Contact configuration IEC 947-5-2 4/5 Verschmutzungsgrad
Mehrengineered to connect y-con And STANDARD RJ45
engineered to connect y-con And STANDARD RJ45 industrial connector system connector solutions Y-CONRJ45 Industrial system overview The Y-ConRJ45 connector system with or without EMI protection in full
MehrISLIKER MAGNETE AG - CH-8450
GI-50.10 GI-50.10 1 / Hub / stroke = 10mm 110.5 9 68.5 3x M O 0 M6 18 SW5 O50 O6 Magnet bestromt gezeichnet Solenoid illustrated in energised position 6 max. Hub / stroke = 10mm 110.5 39 68.5 3x M O 0
MehrMCX (50 Ω) - Mikrominiatur- Koaxialsteckverbinder für Anwendungen bis 6 GHz. (50 Ω) - Microminiature Coaxial Connectors for Frequencies up to 6 GHz
MCX 3 MCX (50 Ω) MCX (50 Ω) 1MCX (50 Ω) (50 Ω) - Microminiature Coaxial Connectors for Frequencies up to 6 GHz MCX - optimal connector series, provided with a snap- on connecting system like SMB connectors,
MehrY-ConRJ45 system overview...
table of contents Y-ConRJ45 system overview... inside cover IP67/68/69K protected components cover for Y-ConRJ45 plugs... 2 metal housing for Y-Con cover... 2 full metal housing for Y-ConRJ45 plugs...
MehrFeldbusleitung mit PVC-Mantel, Typ Profibus, NICHT energieführungskettentauglich BC4500001 BC4500002
0001 0002 150 Ohm Feldbusleitung mit PVC-Mantel, Typ Profibus, NICHT energieführungskettentauglich Art.-Nr. Aderanzahl x Ø Typ Cu-Zahl Gewicht Querschnitt (außen) n x mm 2 mm kg/km kg/km 4500001 1x2x0,64/2,55
MehrHYSLY Flex - JZ, OZ, OB, JB
HYSLY Flex - JZ, OZ, OB, JB mit GOST Zulassung with GOST approval Als Anschluss- und Verbindungsleitung für Steuergeräte von Werkzeugmaschinen, Fließ- und Montagebändern, Förderanlagen, Fertigungsstraßen
MehrPROFIBUS-Kabel. PROFIBUS DP-Kabel Nicht-Ex Anwendungen Ex Anwendungen. PROFIBUS PA-Kabel Nicht-Ex Anwendungen Ex Anwendungen
Datenblatt 10/63-6.47-DE Rev. D PROFIBUS-Kabel PROFIBUS DP-Kabel Nicht-Ex Anwendungen Ex Anwendungen PROFIBUS PA-Kabel Nicht-Ex Anwendungen Ex Anwendungen PROFIBUS-Kabel PROFIBUS DP-Kabel (eindrähtig)
MehrAPPLICATION. bewegt -15 C bis 80 C flexing -15 C to 80 C unbewegt -40 C bis 80 C fixed installation -40 C to 80 C
FLEX-Steuerleitungen sind weitgehend beständig FLEX control cables are largely resitant to acids, bases GLOBALFLEX-JZ PVC-Steuerleitung Production range 2-100 cores, 0,5-120 mm?, registrated by VDE VDE
Mehrengineered to connect y-con industrial connector system connector solutions
engineered to connect y-con industrial connector system connector solutions system overview The Y-ConRJ45 connector system with or without EMI protection in full metal or plastic. Our design offers a solution
MehrLötstift gewinkelt 90, 9.4 mm Gedrehte Kontakte. 90 Solder pin, 9.4 mm Machined contacts. Stiftleiste Plug connector. Buchsenleiste Socket connector
Lötstift gewinkelt 90, 9.4 mm Gedrehte Kontakte 90 Solder pin, 9.4 mm Machined contacts Stiftleiste Plug connector Buchsenleiste Socket connector A A D D 1 2 3 4 5 5 4 3 2 1 7 8 9 Ø 0. 10 9.4 1.3 max.
MehrInduktive Näherungsschalter inductive proximity switches
Zylindrisch DC cylindric DC Zylindrisch DC Vollmetall cylindric DC full metal Hochtemperatur high temperature Schweißfest weld resistant Druckfest pressure resistant Analog analog Namur namur AC AC Kunststoff
MehrZubehör für mehrpolige Steckverbinder
für mehrpolige Steckverbinder Einfache Codierstifte für Codierungen Codierung mit einfachem Codierstift einfache Codierstifte aus Edelstahl aus Stahl, verzinkt (nicht für MIXO Einsätze) CR 20 CR 20 D einfache
MehrAutomatisierungstechnik - Aktorik - Bauform B Automation Technology - Actuatorics - Size B
5 0 Automatisierungstechnik - Aktorik - Automation Technology - Actuatorics - Size B Gerätesteckdosen Magnetventilsteckdosen Verbindungsleitungen DIN EN 7530-803 Industrie + Niedriges Gehäuse Schutzart
MehrHochstromkontakte High Power Contacts
Hochstromkontakte High Power Contacts Technische Daten Technical Data Mechanische Daten Mechanical Data Steckkraft (Kontaktpaar) Mating force (pair of contacts) Ziehkraft Unmating force Temperaturbereich
MehrMagnetventilsteckverbinder. Solenoid Valve Connectors
87 Magnetventilsteckverbinder Solenoid Valve Connectors 0 Automatisierungstechnik - Automation Technology - Size B Gerätesteckdosen Magnetventilsteckdosen Verbindungsleitungen DIN EN 7530-803 Industrie
Mehrengineered to connect y-con industrial connector system connector solutions
engineered to connect y-con industrial connector system connector solutions system overview The Y-ConRJ45 connector system with or without EMI protection in full metal or plastic. Our design offers a solution
MehrISLIKER MAGNETE AG - CH-8450
GKu - Datenblätter GKu - Datasheets AG - CH-40 Andelfingen - Tel. +41 (0)2 30 2 2 - info@islikermagnete.ch - www.islikermagnete.ch GKu GKu Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions
MehrReverse Polarised Connectors R-TNC, R-SMA, R-BNC Reverse polarisierte Steckverbinder R-TNC, R-SMA, R-BNC
15 Reverse Polarised Connectors R-TNC, R-SMA, R-BNC Contents 15.1 R-SMA Straight Plug Crimp............. 272 15.2 R-SMA Angle Plug Crimp............... 272 15.3 R-SMA Straight Jack Crimp..............
MehrFC/PC- und FC/APC-Singlemode-, PM-Patchkabel und Steckerkonfektionen
FC/PC und FC/APCSinglemode, PMPatchkabel An vielen Geräten zur Datenübertragung, Sensorik, Medizintechnik, Steuerung und Industrieanwendung ist der FCSteckertyp, sei es als PC (physical contact) oder als
MehrInterconnection Technology
Interconnection Technology Register: 23 Date: 25.05.99 Measuring leads from Hirschmann Following measuring leads are replaced by the next generation. Additionally connectors and sockets in the same design
MehrLow Profile D-Sub Connectors D-Sub Steckverbinder mit geringer Einbauhöhe
Contact Cambridge Connectors. Phone +44 1223 8641 Email: sales@cambridgeconnectors.com Low Profile D-Sub Connectors D-Sub Steckverbinder mit geringer Einbauhöhe Ordering Code Bestellschlüssel ALL DIMENSIONS
MehrElectrical testing of Bosch common rail solenoid valve (MV) injectors
Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445
MehrElectrical tests on Bosch unit injectors
Valid for Bosch unit injectors with order numbers 0 414 700 / 0 414 701 / 0 414 702 Parts Kit Magnet*: - F00H.N37.925 - F00H.N37.933 - F00H.N37.934 * For allocation to the 10-place Bosch order number,
MehrWir setzen Standards. Connector 4 Small Drives TWINTUS
Wir setzen Standards Connector Small Drives Connector small drives Das kosteneffiziente Stecksystem für energieeffiziente Servomotoren Cost effective connectors for energy efficient servo drives Minimale
MehrIP20 Protected Components
IP0 Protected Components Y-ConIP0Lock-0 Y-ConIP0Lock-0 Y-ConIP0Lock - ** 0 = Standard Type 0 = With Locking Slider Y-ConIP0Lock-0 Y-ConIP0Lock-0 Type Standard With additional locking slider IP0 lock strain
MehrM9 IP40 Subminiature. Cable Connectors Screw termination M9 2 8 contacts Degree of protection IP40 1) Solder termination Diameter 11.
Subminiatur M9 IP0 Subminiatur M9 IP0 Subminiature Kabelsteckverbinder Schraubverriegelung M9 8-polig Schutzart IP0 ) Lötanschluss Durchmesser, mm Flanschsteckverbinder Schraubverriegelung M9 8-polig Schutzart
MehrMicro-RF. 294 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) ,
Micro-RF components can be used up to 6 GHz in various wireless applications, e. g. cellular and cordless phones, Bluetooth and wireless LAN applications, PDAs (Personal Digital Assistants) or wireless
MehrEN 175301-803. Typenschlüssel Order code D I A B C. 3 3-polig / 3 poles 4 4-polig / 4 poles 0 Y G R D T L V E H1 (...9) C S 1 PG 11 9 PG 9
Typenschlüssel Order code G Gerätesteckdose / Connector D I DIN Industrienorm / Industrial A B C Bauform A / form A Bauform B / form B Bauform C / form C 3 3-polig / 3 poles 4 4-polig / 4 poles 0 Y G R
MehrClimatic category acc. to IEC /155/21... Prüfklasse nach DIN IEC 68 Teil 1
12 Contents 12.1 Straight Plug................... 223 12.2 Straight Plug Crimp.............. 223 12.3 Angle Plug.................... 224 12.4 Angle Plug Crimp............... 225 12.5 U Link, male...................
MehrEC7 LINE STP. w INHALT. DATENANSCHLUSSDOSE EC7... Seite 78. PATCHPANEL EC7... Seite 78. MONTAGEWERKZEUG... Seite 78. PATCHKABEL EC7...
IT_KAPITEL_07_AK3:KAPITEL_02_AK1_korr 08.05.2007 7:42 Uhr 75 75 w INHALT DATENANSCHLUSSDOSE EC7... 78 PATCHPANEL EC7... 78 MONTAGEWERKZEUG... 78 PATCHKABEL EC7... 79 KUPFERINSTALLATIONSKABEL S/FTP CAT
MehrSensorik & Aktorik. Sensors & Actuators
1 Sensorik & Aktorik Sensors & Actuators 707 Automatisierungstechnik Automation Technology Kabelsteckverbinder Schraubverriegelung nach DIN EN 61076--105 - und -polig Schutzart IP67 1) Am Kabel angespritzte
MehrM5 Automatisierungstechnik M5 Automation Technology
707 Automatisierungstechnik Automation Technology Kabelsteckverbinder Schraubverriegelung - und -polig Schutzart IP67 ) Am Kabel angespritzte Ausführungen Gewindering mit Rüttelsicherung Flanschsteckverbinder
MehrM16 Steckverbinder IP 40 M16 connectors IP 40
R BF-C BF-B BF-A /8 M8 M-US M-D M-B Verteiler VL M-A M8 M RD0 RD M Bajonett M M IP M IP0 PP IP Bajonett SI IP M9 IP M9 IP0 PP IP MPP IP Bajonett SI IP SI IP0 TI Ü binder M Steckverbinder IP 0 M connectors
MehrM9 Steckverbinder IP40 M9 connectors IP40
R BF-C BF-B BF-A / M M-US M-D M-B Verteiler VL M-A M M RD0 RD M Bajonett M M IP M IP0 PP IP Bajonett SI IP M9 IP M9 IP0 PP IP MPP IP Bajonett SI IP SI IP0 TI Ü binder M9 Steckverbinder IP0 M9 connectors
Mehr10 MCX MCX. 200 Telegärtner Web: Tel: +49-(0) / Fax: +49-(0) /
10 Contents 10.1 Straight Plug.................... 203 10.2 Straight Plug Crimp............... 203 10.3 Angle Plug...................... 203 10.4 Angle Plug Crimp................. 204 10.5 Receptacle,
MehrKurzinformation Brief information. Subminiatur Rundsteckverbinder Serie 711 Subminiature circular connectors series 711 Ü TI
Serie 11 11 0 09 10 11 1 19 0 1 6 60 6 0 6 69 69 69 0 1 1 6 6 6 1 1 66 1 0 Subminiatur undsteckverbinder Serie 11 Subminiature circular connectors series 11 Kabelsteckverbinder Steckverbinder mit Schraubverriegelung
MehrProduktbeschreibung. Product description
Produktbeschreibung Seite Low Cost IC-Fassungen,Raster 2.54 mm 188 Low Cost IC-Fassungen,Raster 778 mm 189 Präzisions IC-Fassungen, Raster 2,54 190 Präzisions IC-Fassungen,Wire-Wrap, 17.80 mm 191 Präzisions
MehrD-Sub, C-Filter, Feed-through Capacitor D-Sub, C-Filter, Durchführungskondensator
D-Sub, C-Filter, Feed-through Capacitor D-Sub, C-Filter, Durchführungskondensator Ordering Code Bestellschlüssel Features, Advantages Merkmale, Vorteile C-Filter Feed-through ceramic capacitor Fully compatible
MehrKupfergeflechte / Massebänder Copper braidings / Earthing straps Blanke Kupfergeflechte Bare copper wire braidings
Kupfergeflechte / Massebänder Copper braidings / Earthing straps Blanke Kupfergeflechte Bare copper wire braidings 1 1 Blanke Kupferdrähte oder blanke Kupferlitze geflochten (rund oder abgeflacht) 1 Bare
MehrMagnetventilsteckverbinder. Solenoid Valve Connectors
7 Magnetventilsteckverbinder Solenoid Valve Connectors 0 Automatisierungstechnik - Automation Technology - Size C Gerätesteckdosen Magnetventilsteckdosen DIN EN 750-0 Industrie +PE, +PE Schutzart IP65/IP67
MehrAutomatisierungstechnik - Aktorik - Bauform C Automation Technology - Actuatorics - Size C
79 Aktorik 5 0 Automatisierungstechnik - Aktorik - Automation Technology - Actuatorics - Size C Gerätesteckdosen Magnetventilsteckdosen DIN EN 750-0 Industrie +PE, +PE Schutzart IP65/IP67 ) Female Power
MehrSolenoid Valves. Magnetventile. Type 65 for Series 65/79/81/83/87. Betätigungsmagnet Typ 65 für Baureihe 65/79/81/83/87
Magnetventile Solenoid Valves Betätigungsmagnet Typ 65 für Baureihe 65/79///7 Type 65 for Series 65/79///7 Elektrische Daten 65er Magnetsystem Elektrische Ausführung: mäß VDE 050, VDE 00 Ansprechstrom:
MehrAutomatisierungstechnik - Aktorik - Bauform C
79 Aktorik 5 0 Automatisierungstechnik - Aktorik - Gerätesteckdosen Magnetventilsteckdosen Female Power Connectors Female Solenoid Valve Connectors 5 0 ) Erläuterung der Schutzarten siehe technische Informationen./
MehrISLIKER MAGNETE AG - CH-8450
DGV - Datenblätter DGV - Datasheets DGV DGV Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] Drehwinkel Rotary angle [ ] Drehmoment Torque [Ncm] DGV-35.95 35/35 x 27.5 95 DGV-50.95
MehrThermische und klimatische Eigenschaften...Climatic Characteristics Prüfklasse nach DIN IEC 68 Teil /155/56...Climatic category acc.
8 Die Serie umfasst sehr häufig verwendete koaxiale Steckverbindungen mit Schraubverschluss. Sie können je nach usführung bis zu einer Frequenz von 18 GHz eingesetzt werden. Der Wellenwiderstand beträgt
MehrMagnetventilsteckverbinder Bauform C Solenoid valve connectors size C
BF-C BF-B BF-A 7/ M M-US M-T M-S M-D M-B Verteiler VL M-A M M5 RD0 RD M5 Bajonett M M6 IP67 M6 IP0 PP IP67 NCC Bajonett SI IP67 M9 IP67 M9 IP0 PP IP67 MPP IP67 Bajonett SI IP67 SI IP0 Magnetventilsteckverbinder
MehrM23 Steckverbinder IP67 M23 connectors IP67
R BF-C BF-B BF-A / M M-US M-D M-B Verteiler M PP VL M-A M M RD0 RD M Bajonett M M IP M IP0 PP IP Bajonett SI IP M IP M IP0 PP IP Bajonett SI IP SI IP0 TI Ü binder M Steckverbinder IP M connectors IP M
MehrOrder Number Bestellnummer. Hand crimp tool Handcrimpzange Positioner Einsatz Positioner Einsatz. Order Number. Bestellnummer
Crimpingtools for Miniature Connectors Crimpwerkzeuge für Miniatursteckverbinder Hand Crimp Tool M22520/2-01 for Machined Contacts Handcrimpzange M22520/2-01 für gedrehte Kontakte Die / Einsatz Hand crimp
MehrUL Recognized File No. E Maintenance or programming interface D-Sub plug, 9 way Service- oder Programmierschnittstelle D-Sub-Stecker 9-polig
Fig. 1: Abb. 1: CANBus Interface Connector FBUSCA FBUSCA Fig. 2: Abb. 2: CANBus Interface Connector FBUSCB-K1452 with second D-Sub connector for connecting programming or diagnosis modules, shielded metallised
MehrUSB Kabelkonfektion USB cabels assembly
USB Kabelkonfektion USB cabels assembly Customized cables Power cords Flat cables D-SUB cables Modular cables USB cables Video- and Audio cables 612 USB - Kabel von ASSMANN WSW components werden in den
MehrRPC- TNC. Rosenberger RPC- TNC connectors are conform to the following specification: Radio- frequency connectors, specified in IEC , grade 0
2 Series RPC- TNC 1Series RPC-TNC TNC Rosenberger RPC- TNC connectors are 50 Ω precision TNC connectors, designed for a frequency range up to 18 GHz, with threaded coupling. The result of the threaded
MehrPCMCIA IC MEMORY CARD PLUGS & SOCKETS
PCMCIA IC MEMORY CARD PLUGS & SOCKETS G e r m a n y - H o n g K o n g - Ta i w a n - T h e N e t h e r l a n d s - S o u t h A f r i c a - U S A QUALITÄT-DIENSTLEISTUNG-INNOVATION QUALITY - SERVICE - INNOVATION
MehrALLNET ALL-HPNA3. Home Phoneline Networking Ethernet Bridge. Benutzerhandbuch
ALLNET ALL-HPNA3 Home Phoneline Networking Ethernet Bridge Benutzerhandbuch EINFÜHRUNG Home Phoneline Networking Alliance, kurz HPNA ist dafür konzipiert, gängige Ethernet-Geräte miteinander zu verbinden.
MehrElectrical testing of Bosch common rail piezo injectors
Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid
MehrMetal Hoods FMK/FMK...G Metallhauben FMK/FMK...G
Metal Hoods FMK/FMK...G Metallhauben FMK/FMK...G Hood Series FMK, Angled Cable Outlet Baureihe FMK, abgewinkelter Kabelausgang Hood Series FMK...G, Straight Cable Outlet Baureihe FMK...G, gerader Kabelausgang
MehrBETAflam ENgine flex EN MM
95 BETAflam ENgine flex EN 50264-3-2 MM Versorgungsleitung, 600 V Installation cable, 600 V Vorteile / Advantages Halogenfrei Hohe Temperaturbeständigkeit, Einsatz bis +125 C Kältebeständigkeit bis 50
MehrAlpha 2T EINBAUANLEITUNG MOUNTINGINSTRUCTIONS
Alpha 2T EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation der Antennenanlage Alpha 2T Die Antennenanlage Alpha 2T besteht aus der Antenne Alpha 2T und dem Antennenverteiler DB1C. Standort der Antenne
MehrKabelstecker, schrauben Male cable connector, screw. Kabel Ø 3,5 5. Cable Ø 3,5 5 ~ 50. M8 x 1. Polzahl. Polzahl Contacts. Bestell-Nr. Ordering-No.
R BF-C BF-B BF-A 7/8 M8 M2-US M2-D M2-B Verteiler M2 PP VL M2-A M5 RD0 RD2 M25 Bajonett M2 M6 IP67 M6 IP0 PP IP67 Bajonett SI IP67 M9 IP67 M9 IP0 PP IP67 Bajonett SI IP67 SI IP0 TI Ü Bezeichnung Description
MehrBETAtrans GKWR. Steuer- und Kontrollleitung, 600/ 1000 V AC SignalandControlCable,600/1000VAC
24 Schienenverkehrstechnik Rolling Stock Application BETAtrans GKWR Steuer- und Kontrollleitung, 600/ 1000 V AC SignalandControlCable,600/1000VAC Vorteile Hohe Flexibilität Gut abisolierbar Dünn, gewichts-
MehrSteckvorrichtungen mit Flachkontakten. Flat blade contact connectors
Steckvorrichtungen mit Flachkontakten Die Flachkontakt-Steckvorrichtungen von REMA erfüllen die Anforderungen der Europäischen Norm EN 1175-1 und dadurch über die ermutungswirkung auch die der Maschinenrichtlinie
Mehr