NIBE F1145PC. Energimärkning. Energy labelling. Wärmemengenzählung TIF 1536-1 331334

Ähnliche Dokumente
NIBE F1226. Energimärkning. Energy labelling. Wärmemengenzählung TIF LEK

NIBE F1345. Energimärkning. Energy labelling. Wärmemengenzählung TIF

NIBE F1245PC. Energimärkning och återvinning. Energy labelling and recovery. Wärmemengenzählung und recycling TIF

NIBE F1226. Energimärkning och återvinning. Energy labelling and recovery. Wärmemengenzählung und recycling TIF LEK

EcoTouch Ai - brine to water. Abbildung 3

Basic Line Ai1 Air air to water. Abbildung 5

EcoTouch Ai - brine to water. Abbildung 3

Roth TerraCompact Ex 8kW

EcoTouch Ai1 Geo brine to water. Abbildung 5

Angaben nach 626/2011

Datenblatt für Verbundanlage aus Kombiheizgerät mit Wärmepumpe, Temperaturregler und Solareinrichtungen, Warmwasserbereitungs-Energieeffizienz

Angaben nach 626/2011

OH 1-11es V - W/W Art.Nr.: B C 35 C A ++ A ++ A ++ A + A B C D E F G /2013

Angaben nach 626/2011

CTA WR Aeroheat AH CI 8i-WR

CTA HTD Aeroheat CN 5a-WSM 200/60

Produktdatenblatt zum Energieverbrauch Supraeco A SAS 11-2 ASM

Produktdatenblatt zum Energieverbrauch Supraeco A SAS 6-2 ASM

Produktdatenblatt zum Energieverbrauch Logatherm WLW196i

Produktdatenblatt zum Energieverbrauch Supraeco A SAO 80-2 ACM solar

Logatherm WPL 11 AR B C 35 C A ++ A + A B C D E F G. db kw kw /2013

((c Q. 35 c. 55 db * * kw A ++ A + A. - db F G. ehepu1 EvEpyE1a G 0 811/ CTA Aeroheat CM 18a

Compress 7000 AW CS7000iAW 13 ORE-T C 35 C A ++ A + A B C D E F G. db kw kw /2013

Produktdatenblatt zum Energieverbrauch STM

Produktdatenblatt zum Energieverbrauch Supraeco T STM SW

VHKS OÖ: Zuerst der Kühlschrank - nun die Heizung Technische und rechtliche Folgen einer EU-Verordnung (Energy related Products - ErP)

Installatörshandbok ELK 15. Installatörshandbok Elkassett. VVM 320, VVM 325, VVM 500, SMO 20, SMO 40 Installer manual Immersion heater

ERP. WPL 18 S basic. WPL 20 basic

NOVELAN HSV1241 LIV 12-HSV 12

Roth AuraCompact PFR 8 kw

Roth AuraCompact PFR 12 kw

Trinkwasser-Wärmepumpe NUOS. Nuos Sol

CEN TC 113 WG 7 pren 14825

SmartFan. Inhalt / Content

Roth Thermo Aura 7kW

CTA Aeroheat CS6is-BWW-D

F1220, F1230, F1120, F1130

INSTALLATION INSTRUCTIONS ENERGY METER FOR SPLIT indoor unit without integrated tank

CTA Aeroheat CS 1-10i

NOVELAN WSV 9.2K3M XL 9 kw 8 kw 47 9 kw db - db

alpha innotec WZS 42H3M XL 5 kw 5 kw 43 5 kw db - db

alpha innotec WZS 62H3M XL 6 kw 6 kw 43 6 kw db - db

F1220, F1230, F1120, F1130

alpha innotec PWZSV 92H1S XL 9 kw 8 kw 47 9 kw db - db

103609CSD22. 7 kw. 10 kw. 11 kw

103601CSD22. 5 kw. 5 kw. 7 kw

103777HSV kw. 9 kw. 7 kw

100609HTD02. 7 kw. 10 kw. 11 kw

100602HTD02. 5 kw. 8 kw. 9 kw

100699HSDV kw. 9 kw. 10 kw

100776HSV kw. 6 kw. 6 kw

100777HSV kw. 9 kw. 7 kw

100772HSV kw. 6 kw. 6 kw

100772HSV kw. 6 kw. 6 kw

alpha innotec LWCV 82R1/ kw kw db 40 db

alpha innotec SWP kw kw db - db

alpha innotec LWCV 82R1/ kw kw db 44 db

NOVELAN SI 26.2H kw kw db - db

100561VS46. 5 kw. 6 kw. 7 kw

100560VS46. 5 kw. 6 kw. 7 kw

103699HDV1201 NOVELAN LADV 9-HDV kw kw db 54 db

103626CSS01. 8 kw. 7 kw - 8 kw

alpha innotec SWCV 92K kw kw db - db

103563VS46. 6 kw. 8 kw. 9 kw

103627CSS kw. 10 kw - 12 kw

103540CS kw. 8 kw. 9 kw

alpha innotec PWZSV 62H3S XL 6 kw 6 kw 43 6 kw db - db

103627CSS kw. 10 kw - 12 kw

Transkript:

NIBE F1145PC SE GB DE Energimärkning Energy labelling Wärmemengenzählung LEK TIF 15361 331334

Svenska, Installatörshandbok NIBE F1145PC SE Informationsblad Tillverkare varmvattenberedare Temperaturtillämpning Deklarerad tapprofil varmvattenberedning Effektivitetsklass rumsuppvärmning, medelklimat Effektivitetsklass varmvattenberedning, medelklimat Nominell värmeeffekt (Pdesignh), medelklimat Årlig energiförbrukning rumsuppvärmning, medelklimat Årlig energiförbrukning varmvattenberedning, medelklimat Säsongsmedelverkningsgrad rumsuppvärmning, medelklimat Energieffektivitet varmvattenberedning, medelklimat Ljudeffektnivå L WA inomhus Nominell värmeeffekt (Pdesignh), kallt klimat Nominell värmeeffekt (Pdesignh), varmt klimat Årlig energiförbrukning rumsuppvärmning, kallt klimat Årlig energiförbrukning varmvattenberedning, kallt klimat Årlig energiförbrukning rumsuppvärmning, varmt klimat Årlig energiförbrukning varmvattenberedning, varmt klimat Säsongsmedelverkningsgrad rumsuppvärmning, kallt klimat Energieffektivitet varmvattenberedning, kallt klimat Säsongsmedelverkningsgrad rumsuppvärmning, varmt klimat Energieffektivitet varmvattenberedning, varmt klimat Ljudeffektnivå L WA utomhus h h h h h h NIBE AB F1145PC5 1x230V A++ / A++ A 2 669 / 3 027 172 / 128 43 3 097 / 3 495 1 731 / 1 985 177 / 133 171 / 127 3

SE Tillverkare NIBE AB F1145PC5 3x400V F1145PC6 3x400V F1145PC8 3x400V F1145PC10 3x400V varmvattenberedare Temperaturtillämpning Deklarerad tapprofil varmvattenberedning Effektivitetsklass rumsuppvärmning, medelklimat Effektivitetsklass varmvattenberedning, medelklimat Nominell värmeeffekt (Pdesignh), medelklimat Årlig energiförbrukning rumsuppvärmning, medelklimat Årlig energiförbrukning varmvattenberedning, medelklimat Säsongsmedelverkningsgrad rumsuppvärmning, medelklimat Energieffektivitet varmvattenberedning, medelklimat Ljudeffektnivå L WA inomhus Nominell värmeeffekt (Pdesignh), kallt klimat Nominell värmeeffekt (Pdesignh), varmt klimat Årlig energiförbrukning rumsuppvärmning, kallt klimat Årlig energiförbrukning varmvattenberedning, kallt klimat Årlig energiförbrukning rumsuppvärmning, varmt klimat Årlig energiförbrukning varmvattenberedning, varmt klimat Säsongsmedelverkningsgrad rumsuppvärmning, kallt klimat Energieffektivitet varmvattenberedning, kallt klimat Säsongsmedelverkningsgrad rumsuppvärmning, varmt klimat Energieffektivitet varmvattenberedning, varmt klimat Ljudeffektnivå L WA utomhus h h h h h h A++ / A++ A 2 669 / 3 027 172 / 128 43 3 097 / 3 495 1 731 / 1 985 177 / 133 171 / 127 A++ / A++ A 7 / 6 3 010 / 3 425 2 025 184 / 137 106 43 7 / 6 7 / 6 3 487 / 3 969 2 025 1 966 / 2 237 2 025 190 / 141 106 182 / 135 106 A++ / A++ A 9 / 8 3 797 / 4 433 1 995 188 / 141 108 45 9 / 8 9 / 8 4 393 / 5 142 1 995 2 463 / 2 864 1 995 194 / 145 108 187 / 141 108 A++ / A++ A 12 / 10 4 90 345 1 945 194 / 147 111 45 12 / 10 12 / 10 5 695 / 6 214 1 945 3 173 / 3 462 1 945 200 / 151 111 194 / 146 111 4

SE Data för systemets energieffektivitet varmvattenberedare Temperaturtillämpning Temperaturregulator, klass Temperaturregulator, bidrag till effektivitet Systemets säsongsmedelverkningsgrad rumsuppvärmning, medelklimat Systemets effektivitetsklass rumsuppvärmning, medelklimat Systemets säsongsmedelverkningsgrad rumsuppvärmning, kallt klimat Systemets säsongsmedelverkningsgrad rumsuppvärmning, varmt klimat F1145PC5 1x230V VII 3,5 175 / 132 A+++ / A++ 180 / 137 175 / 130 F1145PC5 3x400V F1145PC6 3x400V F1145PC8 3x400V F1145PC10 3x400V varmvattenberedare Temperaturtillämpning Temperaturregulator, klass VII Temperaturregulator, bidrag till effektivitet Systemets säsongsmedelverkningsgrad rumsuppvärmning, medelklimat Systemets effektivitetsklass rumsuppvärmning, medelklimat Systemets säsongsmedelverkningsgrad rumsuppvärmning, kallt klimat Systemets säsongsmedelverkningsgrad rumsuppvärmning, varmt klimat 175 / 132 A+++ / A++ 180 / 137 175 / 130 188 / 140 A+++ / A++ 193 / 145 186 / 139 3,5 191 / 145 A+++ / A++ 198 / 149 191 / 145 198 / 150 A+++ 203 / 154 198 / 150 Redovisad effektivitet för systemet tar även hänsyn till dess temperaturregulator. Om systemet kompletteras med extern tillsatspanna eller solvärme ska den totala effektiviteten för systemet räknas om. 5

SE Teknisk dokumentation F1145PC5 1x230V varmvattenberedare Typ av värmepump Lågtemperaturvärmepump Inbyggd elpatron för tillsats Värmepump för värme och varmvatten Klimat Temperaturtillämpning Tillämpade standarder Nominell avgiven värmeeffekt Prated Luftvatten Frånluftvatten Vätskavatten Vattenvatten Nej Nej Nej Medel Kallt Varmt Medel (55 ) EN14825 & EN16147 Deklarerad kapacitet för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 5,0 3,5 4,1 4,3 4,6 3,8 3,2 Låg (35 ) Säsongsmedelverkningsgrad för rumsuppvärmning ƞ s 128 Deklarerad COP för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 2,99 3,57 3,84 4,04 3,26 2,74 Bivalenttemperatur Kapacitet vid cykling Degraderingskoefficient T biv Pcych Cdh 3,9 0,99 Min uteluftstemperatur COP vid cykling Max framledningstemperatur TOL COPcyc WTOL 10 65 Effektförbrukning i andra lägen än aktivt läge Frånläge Termostatfrånläge Standbyläge Vevhusvärmarläge P OFF P TO P SB P CK 0,002 0,008 0,007 0,012 Tillsatsvärme Nominell värmeeffekt Typ av tillförd energi Psup 1,8 Elektrisk Övriga poster Kapacitetsreglering Ljudeffektnivå, inomhus/utomhus Årlig energiförbrukning L WA Q HE Fast 43 / 3 027 h Nominellt luftflöde (luftvatten) Nominellt värmebärarflöde Köldbärarflöde vätskavatten eller vattenvattenvärmepumpar 0,35 0,62 För värmepump med både rumsuppvärmning och varmvattenberedning Deklarerad tapprofil varmvattenberedning Daglig energiförbrukning Q elec 9,73 h Årlig energiförbrukning AEC h Energieffektivitet varmvattenberedning Daglig bränsleförbrukning Årlig bränsleförbrukning ƞ wh Q fuel AFC h GJ 6

SE F1145PC5 3x400V varmvattenberedare Typ av värmepump Lågtemperaturvärmepump Inbyggd elpatron för tillsats Värmepump för värme och varmvatten Klimat Temperaturtillämpning Tillämpade standarder Nominell avgiven värmeeffekt Prated Luftvatten Frånluftvatten Vätskavatten Vattenvatten Nej Nej Nej Medel Kallt Varmt Medel (55 ) EN14825 & EN16147 Deklarerad kapacitet för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 5,0 3,5 4,1 4,3 4,6 3,8 3,2 Låg (35 ) Säsongsmedelverkningsgrad för rumsuppvärmning ƞ s 128 Deklarerad COP för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 2,99 3,57 3,84 4,04 3,26 2,74 Bivalenttemperatur Kapacitet vid cykling Degraderingskoefficient T biv Pcych Cdh 3,9 0,99 Min uteluftstemperatur COP vid cykling Max framledningstemperatur TOL COPcyc WTOL 10 65 Effektförbrukning i andra lägen än aktivt läge Frånläge Termostatfrånläge Standbyläge Vevhusvärmarläge P OFF P TO P SB P CK 0,002 0,008 0,007 0,012 Tillsatsvärme Nominell värmeeffekt Typ av tillförd energi Psup 1,8 Elektrisk Övriga poster Kapacitetsreglering Ljudeffektnivå, inomhus/utomhus Årlig energiförbrukning L WA Q HE Fast 43 / 3 027 h Nominellt luftflöde (luftvatten) Nominellt värmebärarflöde Köldbärarflöde vätskavatten eller vattenvattenvärmepumpar 0,35 0,62 För värmepump med både rumsuppvärmning och varmvattenberedning Deklarerad tapprofil varmvattenberedning Daglig energiförbrukning Q elec 9,73 h Årlig energiförbrukning AEC h Energieffektivitet varmvattenberedning Daglig bränsleförbrukning Årlig bränsleförbrukning ƞ wh Q fuel AFC h GJ 7

SE F1145PC6 3x400V varmvattenberedare Typ av värmepump Lågtemperaturvärmepump Inbyggd elpatron för tillsats Värmepump för värme och varmvatten Klimat Temperaturtillämpning Tillämpade standarder Nominell avgiven värmeeffekt Prated Luftvatten Frånluftvatten Vätskavatten Vattenvatten Nej Nej Nej Medel Kallt Varmt Medel (55 ) EN14825 & EN16147 Deklarerad kapacitet för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 6,0 4,8 5,3 5,6 6,0 4,9 4,5 Låg (35 ) Säsongsmedelverkningsgrad för rumsuppvärmning ƞ s 137 Deklarerad COP för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 3,18 3,69 4,02 4,29 3,30 2,96 Bivalenttemperatur Kapacitet vid cykling Degraderingskoefficient T biv Pcych Cdh 5,3 0,99 Min uteluftstemperatur COP vid cykling Max framledningstemperatur TOL COPcyc WTOL 10 65 Effektförbrukning i andra lägen än aktivt läge Frånläge Termostatfrånläge Standbyläge Vevhusvärmarläge P OFF P TO P SB P CK 0,002 0,010 0,007 0,014 Tillsatsvärme Nominell värmeeffekt Typ av tillförd energi Psup 1,5 Elektrisk Övriga poster Kapacitetsreglering Ljudeffektnivå, inomhus/utomhus Årlig energiförbrukning L WA Q HE Fast 43 / 3 425 h Nominellt luftflöde (luftvatten) Nominellt värmebärarflöde Köldbärarflöde vätskavatten eller vattenvattenvärmepumpar 0,49 0,90 För värmepump med både rumsuppvärmning och varmvattenberedning Deklarerad tapprofil varmvattenberedning Daglig energiförbrukning Q elec 9,22 h Årlig energiförbrukning AEC 2 025 h Energieffektivitet varmvattenberedning Daglig bränsleförbrukning Årlig bränsleförbrukning ƞ wh Q fuel AFC 106 h GJ 8

SE F1145PC8 3x400V varmvattenberedare Typ av värmepump Lågtemperaturvärmepump Inbyggd elpatron för tillsats Värmepump för värme och varmvatten Klimat Temperaturtillämpning Tillämpade standarder Nominell avgiven värmeeffekt Prated Luftvatten Frånluftvatten Vätskavatten Vattenvatten Nej Nej Nej Medel Kallt Varmt Medel (55 ) EN14825 & EN16147 Deklarerad kapacitet för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 8,0 6,2 6,9 7,2 7,6 6,4 5,9 Låg (35 ) Säsongsmedelverkningsgrad för rumsuppvärmning ƞ s 141 Deklarerad COP för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 3,28 3,81 4,13 4,41 3,44 3,07 Bivalenttemperatur Kapacitet vid cykling Degraderingskoefficient T biv Pcych Cdh 4,9 0,99 Min uteluftstemperatur COP vid cykling Max framledningstemperatur TOL COPcyc WTOL 10 65 Effektförbrukning i andra lägen än aktivt läge Frånläge Termostatfrånläge Standbyläge Vevhusvärmarläge P OFF P TO P SB P CK 0,002 0,012 0,007 0,014 Tillsatsvärme Nominell värmeeffekt Typ av tillförd energi Psup 2,1 Elektrisk Övriga poster Kapacitetsreglering Ljudeffektnivå, inomhus/utomhus Årlig energiförbrukning L WA Q HE Fast 45 / 4 433 h Nominellt luftflöde (luftvatten) Nominellt värmebärarflöde Köldbärarflöde vätskavatten eller vattenvattenvärmepumpar 0,64 1,20 För värmepump med både rumsuppvärmning och varmvattenberedning Deklarerad tapprofil varmvattenberedning Daglig energiförbrukning Q elec 9,09 h Årlig energiförbrukning AEC 1 995 h Energieffektivitet varmvattenberedning Daglig bränsleförbrukning Årlig bränsleförbrukning ƞ wh Q fuel AFC 108 h GJ 9

SE F1145PC10 3x400V varmvattenberedare Typ av värmepump Lågtemperaturvärmepump Inbyggd elpatron för tillsats Värmepump för värme och varmvatten Klimat Temperaturtillämpning Tillämpade standarder Nominell avgiven värmeeffekt Prated Luftvatten Frånluftvatten Vätskavatten Vattenvatten Nej Nej Nej Medel Kallt Varmt Medel (55 ) EN14825 & EN16147 10,0 Deklarerad kapacitet för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 7,9 8,7 9,2 9,6 8,2 7,6 Låg (35 ) Säsongsmedelverkningsgrad för rumsuppvärmning ƞ s 147 Deklarerad COP för rumsuppvärmning vid dellast och vid utomhustemperatur = 7 = +2 = +7 = +12 = 15 (om TOL < 20 ) 3,40 3,91 4,25 4,58 3,52 3,19 Bivalenttemperatur Kapacitet vid cykling Degraderingskoefficient T biv Pcych Cdh 5,2 1,00 Min uteluftstemperatur COP vid cykling Max framledningstemperatur TOL COPcyc WTOL 10 65 Effektförbrukning i andra lägen än aktivt läge Frånläge Termostatfrånläge Standbyläge Vevhusvärmarläge P OFF P TO P SB P CK 0,002 0,010 0,007 0,014 Tillsatsvärme Nominell värmeeffekt Typ av tillförd energi Psup 2,4 Elektrisk Övriga poster Kapacitetsreglering Ljudeffektnivå, inomhus/utomhus Årlig energiförbrukning L WA Q HE Fast 45 / 5 345 h Nominellt luftflöde (luftvatten) Nominellt värmebärarflöde Köldbärarflöde vätskavatten eller vattenvattenvärmepumpar 0,82 1,56 För värmepump med både rumsuppvärmning och varmvattenberedning Deklarerad tapprofil varmvattenberedning Daglig energiförbrukning Q elec 8,86 h Årlig energiförbrukning AEC 1 945 h Energieffektivitet varmvattenberedning Daglig bränsleförbrukning Årlig bränsleförbrukning ƞ wh Q fuel AFC 111 h GJ 10

English, Installer manual NIBE F1145PC GB Information sheet Supplier Model Model hot water heater Temperature application Declared load profile for water heating Seasonal space heating energy efficiency class, average climate Water heating energy efficiency class, average climate Rated heat output (Pdesignh), average climate Annual energy consumption space heating, average climate Annual energy consumption water heating, average climate Seasonal space heating energy efficiency, average climate Water heating energy efficiency, average climate Sound power level L WA indoors Rated heat output (Pdesignh), cold climate Rated heat output (Pdesignh), warm climate Annual energy consumption space heating, cold climate Annual energy consumption water heating, cold climate Annual energy consumption space heating, warm climate Annual energy consumption water heating, warm climate Seasonal space heating energy efficiency, cold climate Water heating energy efficiency, cold climate Seasonal space heating energy efficiency, warm climate Water heating energy efficiency, warm climate Sound power level L WA outdoors h h h h h h NIBE AB F1145PC5 1x230V A++ / A++ A 2 669 / 3 027 172 / 128 43 3 097 / 3 495 1 731 / 1 985 177 / 133 171 / 127 11

GB Supplier NIBE AB Model F1145PC5 3x400V F1145PC6 3x400V F1145PC8 3x400V F1145PC10 3x400V Model hot water heater Temperature application Declared load profile for water heating Seasonal space heating energy efficiency class, average climate Water heating energy efficiency class, average climate Rated heat output (Pdesignh), average climate Annual energy consumption space heating, average climate Annual energy consumption water heating, average climate Seasonal space heating energy efficiency, average climate Water heating energy efficiency, average climate Sound power level L WA indoors Rated heat output (Pdesignh), cold climate Rated heat output (Pdesignh), warm climate Annual energy consumption space heating, cold climate Annual energy consumption water heating, cold climate Annual energy consumption space heating, warm climate Annual energy consumption water heating, warm climate Seasonal space heating energy efficiency, cold climate Water heating energy efficiency, cold climate Seasonal space heating energy efficiency, warm climate Water heating energy efficiency, warm climate Sound power level L WA outdoors h h h h h h A++ / A++ A 2 669 / 3 027 172 / 128 43 3 097 / 3 495 1 731 / 1 985 177 / 133 171 / 127 A++ / A++ A 7 / 6 3 010 / 3 425 2 025 184 / 137 106 43 7 / 6 7 / 6 3 487 / 3 969 2 025 1 966 / 2 237 2 025 190 / 141 106 182 / 135 106 A++ / A++ A 9 / 8 3 797 / 4 433 1 995 188 / 141 108 45 9 / 8 9 / 8 4 393 / 5 142 1 995 2 463 / 2 864 1 995 194 / 145 108 187 / 141 108 A++ / A++ A 12 / 10 4 90 345 1 945 194 / 147 111 45 12 / 10 12 / 10 5 695 / 6 214 1 945 3 173 / 3 462 1 945 200 / 151 111 194 / 146 111 12

GB Data for energy efficiency of the package Model Model hot water heater Temperature application Controller, class Controller, contribution to efficiency Seasonal space heating energy efficiency of the package, average climate Seasonal space heating energy efficiency class of the package, average climate Seasonal space heating energy efficiency of the package, cold climate Seasonal space heating energy efficiency of the package, warm climate F1145PC5 1x230V VII 3,5 175 / 132 A+++ / A++ 180 / 137 175 / 130 Model F1145PC5 3x400V F1145PC6 3x400V F1145PC8 3x400V F1145PC10 3x400V Model hot water heater Temperature application Controller, class VII Controller, contribution to efficiency Seasonal space heating energy efficiency of the package, average climate Seasonal space heating energy efficiency class of the package, average climate Seasonal space heating energy efficiency of the package, cold climate Seasonal space heating energy efficiency of the package, warm climate 175 / 132 A+++ / A++ 180 / 137 175 / 130 188 / 140 A+++ / A++ 193 / 145 186 / 139 3,5 191 / 145 A+++ / A++ 198 / 149 191 / 145 198 / 150 A+++ 203 / 154 198 / 150 The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to the package, the overall efficiency of the package should be recalculated. 13

GB Technical documentation Model F1145PC5 1x230V Model hot water heater Type of heat pump Lowtemperature heat pump Integrated immersion heater for additional heat Heat pump combination heater Climate Temperature application Applied standards Rated heat output Prated Airwater Exhaustwater Brinewater Waterwater Yes Yes Yes No No No Average Cold Warm Average (55 ) EN14825 & EN16147 Declared capacity for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 5,0 3,5 4,1 4,3 4,6 3,8 3,2 Low (35 ) Seasonal space heating energy efficiency ƞ s 128 Declared coefficient of performance for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 2,99 3,57 3,84 4,04 3,26 2,74 Bivalent temperature Cycling interval capacity Degradation coefficient T biv Pcych Cdh 3,9 0,99 Min. outdoor air temperature Cycling interval efficiency Max supply temperature TOL COPcyc WTOL 10 65 Power consumption in modes other than active mode Off mode P OFF Thermostatoff mode P TO Standby mode P SB Crankcase heater mode P CK 0,002 0,008 0,007 0,012 Additional heat Rated heat output Type of energy input Psup 1,8 Electric Other items Capacity control Sound power level, indoors/outdoors Annual energy consumption L WA Q HE Fixed 43 / 3 027 h Rated airflow (airwater) Nominal heating medium flow Brine flow brinewater or waterwater heat pumps 0,35 0,62 For heat pump combination heater Declared load profile for water heating Daily energy consumption Annual energy consumption Q elec AEC 9,73 h h Water heating energy efficiency Daily fuel consumption Annual fuel consumption ƞ wh Q fuel AFC h GJ 14

GB Model F1145PC5 3x400V Model hot water heater Type of heat pump Lowtemperature heat pump Integrated immersion heater for additional heat Heat pump combination heater Climate Temperature application Applied standards Rated heat output Prated Airwater Exhaustwater Brinewater Waterwater Yes Yes Yes No No No Average Cold Warm Average (55 ) EN14825 & EN16147 Declared capacity for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 5,0 3,5 4,1 4,3 4,6 3,8 3,2 Low (35 ) Seasonal space heating energy efficiency ƞ s 128 Declared coefficient of performance for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 2,99 3,57 3,84 4,04 3,26 2,74 Bivalent temperature Cycling interval capacity Degradation coefficient T biv Pcych Cdh 3,9 0,99 Min. outdoor air temperature Cycling interval efficiency Max supply temperature TOL COPcyc WTOL 10 65 Power consumption in modes other than active mode Off mode P OFF Thermostatoff mode P TO Standby mode P SB Crankcase heater mode P CK 0,002 0,008 0,007 0,012 Additional heat Rated heat output Type of energy input Psup 1,8 Electric Other items Capacity control Sound power level, indoors/outdoors Annual energy consumption L WA Q HE Fixed 43 / 3 027 h Rated airflow (airwater) Nominal heating medium flow Brine flow brinewater or waterwater heat pumps 0,35 0,62 For heat pump combination heater Declared load profile for water heating Daily energy consumption Annual energy consumption Q elec AEC 9,73 h h Water heating energy efficiency Daily fuel consumption Annual fuel consumption ƞ wh Q fuel AFC h GJ 15

GB Model F1145PC6 3x400V Model hot water heater Type of heat pump Lowtemperature heat pump Integrated immersion heater for additional heat Heat pump combination heater Climate Temperature application Applied standards Rated heat output Prated Airwater Exhaustwater Brinewater Waterwater Yes Yes Yes No No No Average Cold Warm Average (55 ) EN14825 & EN16147 Declared capacity for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 6,0 4,8 5,3 5,6 6,0 4,9 4,5 Low (35 ) Seasonal space heating energy efficiency ƞ s 137 Declared coefficient of performance for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 3,18 3,69 4,02 4,29 3,30 2,96 Bivalent temperature Cycling interval capacity Degradation coefficient T biv Pcych Cdh 5,3 0,99 Min. outdoor air temperature Cycling interval efficiency Max supply temperature TOL COPcyc WTOL 10 65 Power consumption in modes other than active mode Off mode P OFF Thermostatoff mode P TO Standby mode P SB Crankcase heater mode P CK 0,002 0,010 0,007 0,014 Additional heat Rated heat output Type of energy input Psup 1,5 Electric Other items Capacity control Sound power level, indoors/outdoors Annual energy consumption L WA Q HE Fixed 43 / 3 425 h Rated airflow (airwater) Nominal heating medium flow Brine flow brinewater or waterwater heat pumps 0,49 0,90 For heat pump combination heater Declared load profile for water heating Daily energy consumption Annual energy consumption Q elec AEC 9,22 2 025 h h Water heating energy efficiency Daily fuel consumption Annual fuel consumption ƞ wh Q fuel AFC 106 h GJ 16

GB Model F1145PC8 3x400V Model hot water heater Type of heat pump Lowtemperature heat pump Integrated immersion heater for additional heat Heat pump combination heater Climate Temperature application Applied standards Rated heat output Prated Airwater Exhaustwater Brinewater Waterwater Yes Yes Yes No No No Average Cold Warm Average (55 ) EN14825 & EN16147 Declared capacity for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 8,0 6,2 6,9 7,2 7,6 6,4 5,9 Low (35 ) Seasonal space heating energy efficiency ƞ s 141 Declared coefficient of performance for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 3,28 3,81 4,13 4,41 3,44 3,07 Bivalent temperature Cycling interval capacity Degradation coefficient T biv Pcych Cdh 4,9 0,99 Min. outdoor air temperature Cycling interval efficiency Max supply temperature TOL COPcyc WTOL 10 65 Power consumption in modes other than active mode Off mode P OFF Thermostatoff mode P TO Standby mode P SB Crankcase heater mode P CK 0,002 0,012 0,007 0,014 Additional heat Rated heat output Type of energy input Psup 2,1 Electric Other items Capacity control Sound power level, indoors/outdoors Annual energy consumption L WA Q HE Fixed 45 / 4 433 h Rated airflow (airwater) Nominal heating medium flow Brine flow brinewater or waterwater heat pumps 0,64 1,20 For heat pump combination heater Declared load profile for water heating Daily energy consumption Annual energy consumption Q elec AEC 9,09 1 995 h h Water heating energy efficiency Daily fuel consumption Annual fuel consumption ƞ wh Q fuel AFC 108 h GJ 17

GB Model F1145PC10 3x400V Model hot water heater Type of heat pump Lowtemperature heat pump Integrated immersion heater for additional heat Heat pump combination heater Climate Temperature application Applied standards Rated heat output Prated Airwater Exhaustwater Brinewater Waterwater Yes Yes Yes No No No Average Cold Warm Average (55 ) EN14825 & EN16147 10,0 Declared capacity for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 7,9 8,7 9,2 9,6 8,2 7,6 Low (35 ) Seasonal space heating energy efficiency ƞ s 147 Declared coefficient of performance for space heating at part load and at outdoor temperature = 7 = +2 = +7 = +12 = 15 (if TOL < 20 ) 3,40 3,91 4,25 4,58 3,52 3,19 Bivalent temperature Cycling interval capacity Degradation coefficient T biv Pcych Cdh 5,2 1,00 Min. outdoor air temperature Cycling interval efficiency Max supply temperature TOL COPcyc WTOL 10 65 Power consumption in modes other than active mode Off mode P OFF Thermostatoff mode P TO Standby mode P SB Crankcase heater mode P CK 0,002 0,010 0,007 0,014 Additional heat Rated heat output Type of energy input Psup 2,4 Electric Other items Capacity control Sound power level, indoors/outdoors Annual energy consumption L WA Q HE Fixed 45 / 5 345 h Rated airflow (airwater) Nominal heating medium flow Brine flow brinewater or waterwater heat pumps 0,82 1,56 For heat pump combination heater Declared load profile for water heating Daily energy consumption Annual energy consumption Q elec AEC 8,86 1 945 h h Water heating energy efficiency Daily fuel consumption Annual fuel consumption ƞ wh Q fuel AFC 111 h GJ 18

Deutsch, Installateurhandbuch NIBE F1145PC DE Informationsblatt Hersteller Brauchwasserspeicher Temperatureignung Deklariertes Verbrauchsprofil Brauchwasserbereitung Effizienzklasse Raumerwärmung, europäisches Durchschnittsklima Effizienzklasse Brauchwasserbereitung, europäisches Durchschnittsklima Nominelle Heizleistung (Pdesignh), europäisches Durchschnittsklima hresenergieverbrauch Raumerwärmung, europäisches Durchschnittsklima hresenergieverbrauch Brauchwasserbereitung, europäisches Durchschnittsklima Mittlerer Saisonwirkungsgrad Raumerwärmung, europäisches Durchschnittsklima Energieeffizienz Brauchwasserbereitung, europäisches Durchschnittsklima Schallleistungspegel L WA im Innenbereich Nominelle Heizleistung (Pdesignh), kaltes Klima Nominelle Heizleistung (Pdesignh), warmes Klima hresenergieverbrauch Raumerwärmung, kaltes Klima hresenergieverbrauch Brauchwasserbereitung, kaltes Klima hresenergieverbrauch Raumerwärmung, warmes Klima hresenergieverbrauch Brauchwasserbereitung, warmes Klima Mittlerer Saisonwirkungsgrad Raumerwärmung, kaltes Klima Energieeffizienz Brauchwasserbereitung, kaltes Klima Mittlerer Saisonwirkungsgrad Raumerwärmung, warmes Klima Energieeffizienz Brauchwasserbereitung, warmes Klima Schallleistungspegel L wa im Außenbereich h h h h h h NIBE AB F1145PC5 1x230V A++ / A++ A 2 669 / 3 027 172 / 128 43 3 097 / 3 495 1 731 / 1 985 177 / 133 171 / 127 19

DE Hersteller NIBE AB F1145PC5 3x400V F1145PC6 3x400V F1145PC8 3x400V F1145PC10 3x400V Brauchwasserspeicher Temperatureignung Deklariertes Verbrauchsprofil Brauchwasserbereitung Effizienzklasse Raumerwärmung, europäisches Durchschnittsklima Effizienzklasse Brauchwasserbereitung, europäisches Durchschnittsklima Nominelle Heizleistung (Pdesignh), europäisches Durchschnittsklima hresenergieverbrauch Raumerwärmung, europäisches Durchschnittsklima hresenergieverbrauch Brauchwasserbereitung, europäisches Durchschnittsklima Mittlerer Saisonwirkungsgrad Raumerwärmung, europäisches Durchschnittsklima Energieeffizienz Brauchwasserbereitung, europäisches Durchschnittsklima Schallleistungspegel L WA im Innenbereich Nominelle Heizleistung (Pdesignh), kaltes Klima Nominelle Heizleistung (Pdesignh), warmes Klima hresenergieverbrauch Raumerwärmung, kaltes Klima hresenergieverbrauch Brauchwasserbereitung, kaltes Klima hresenergieverbrauch Raumerwärmung, warmes Klima hresenergieverbrauch Brauchwasserbereitung, warmes Klima Mittlerer Saisonwirkungsgrad Raumerwärmung, kaltes Klima Energieeffizienz Brauchwasserbereitung, kaltes Klima Mittlerer Saisonwirkungsgrad Raumerwärmung, warmes Klima Energieeffizienz Brauchwasserbereitung, warmes Klima Schallleistungspegel L wa im Außenbereich h h h h h h A++ / A++ A 2 669 / 3 027 172 / 128 43 3 097 / 3 495 1 731 / 1 985 177 / 133 171 / 127 A++ / A++ A 7 / 6 3 010 / 3 425 2 025 184 / 137 106 43 7 / 6 7 / 6 3 487 / 3 969 2 025 1 966 / 2 237 2 025 190 / 141 106 182 / 135 106 A++ / A++ A 9 / 8 3 797 / 4 433 1 995 188 / 141 108 45 9 / 8 9 / 8 4 393 / 5 142 1 995 2 463 / 2 864 1 995 194 / 145 108 187 / 141 108 A++ / A++ A 12 / 10 4 90 345 1 945 194 / 147 111 45 12 / 10 12 / 10 5 695 / 6 214 1 945 3 173 / 3 462 1 945 200 / 151 111 194 / 146 111 20

DE Energieeffizienzdaten für die Einheit Brauchwasserspeicher Temperatureignung Temperaturregler, Klasse Temperaturregler, Beitrag zur Effizienz Mittlerer Saisonwirkungsgrad der Einheit für die Raumerwärmung, europäisches Durchschnittsklima Effizienzklasse der Einheit für die Raumerwärmung, europäisches Durchschnittsklima Mittlerer Saisonwirkungsgrad der Einheit für die Raumerwärmung, kaltes Klima Mittlerer Saisonwirkungsgrad der Einheit für die Raumerwärmung, warmes Klima F1145PC5 1x230V VII 3,5 175 / 132 A+++ / A++ 180 / 137 175 / 130 F1145PC5 3x400V F1145PC6 3x400V F1145PC8 3x400V F1145PC10 3x400V Brauchwasserspeicher Temperatureignung Temperaturregler, Klasse VII Temperaturregler, Beitrag zur Effizienz Mittlerer Saisonwirkungsgrad der Einheit für die Raumerwärmung, europäisches Durchschnittsklima Effizienzklasse der Einheit für die Raumerwärmung, europäisches Durchschnittsklima Mittlerer Saisonwirkungsgrad der Einheit für die Raumerwärmung, kaltes Klima Mittlerer Saisonwirkungsgrad der Einheit für die Raumerwärmung, warmes Klima 175 / 132 A+++ / A++ 180 / 137 175 / 130 188 / 140 A+++ / A++ 193 / 145 186 / 139 3,5 191 / 145 A+++ / A++ 198 / 149 191 / 145 198 / 150 A+++ 203 / 154 198 / 150 Die angegebene Effizienz für die Einheit berücksichtigt auch den Temperaturregler. Wenn die Einheit um einen externen Zusatzheizungskessel oder Solarwärme ergänzt wird, muss die Gesamteffizienz für die Einheit neu berechnet werden. 21

DE Technische Dokumentation F1145PC5 1x230V Brauchwasserspeicher Wärmepumpentyp NiedrigtemperaturWärmepumpe Integrierte Elektroheizpatrone für Zusatzheizung Wärmepumpe für Heizung und Brauchwasser Klima Temperatureignung Geltende Normen Abgegebene Nennheizleistung Prated Luft/Wasser Abluft/Wasser Flüssigkeit/Wasser Wasser/Wasser Nein Nein Nein Mittel Kalt Warm Mittel (55) EN14825 & EN16147 Deklarierte Kapazität für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 5,0 3,5 4,1 4,3 4,6 3,8 3,2 Niedrig (35) Mittlerer Saisonwirkungsgrad für Raumerwärmung ƞ s 128 Deklarierter COP für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 2,99 3,57 3,84 4,04 3,26 2,74 Bivalenztemperatur Kapazität bei zyklischem Betrieb Abbaukoeffizient T biv Pcych Cdh 3,9 0,99 Min. Außenlufttemperatur COP bei zyklischem Betrieb Max. Vorlauftemperatur TOL COPcyc WTOL 10 65 Leistungsaufnahme in anderen Stellungen als der aktiven Stellung Ausgeschaltete Stellung P OFF 0,002 Thermostat ausgeschaltete Stellung P TO 0,008 StandbyModus P SB 0,007 Kurbelgehäuseheizermodus P CK 0,012 Zusatzheizung Nennheizleistung Typ der zugeführten Energie Psup 1,8 Elektrisch Sonstige Posten Kapazitätsregelung Schallleistungspegel, Innen/Außenbereich hresenergieverbrauch L WA Q HE Fest 43 / 3 027 h Nomineller Luftvolumenstrom (LuftWasser) Nennfluss Wärmeträger Volumenstrom Wärmequellenmedium Flüssigkeit/Wasser oder Wasser/WasserWärmepumpen 0,35 0,62 Für Wärmepumpe mit Raumerwärmung und Brauchwasserbereitung Deklariertes Verbrauchsprofil Brauchwasserbereitung Täglicher Energieverbrauch hresenergieverbrauch Q elec AEC 9,73 h h Energieeffizienz Brauchwasserbereitung Tagesbrennstoffverbrauch hresbrennstoffverbrauch ƞ wh Q fuel AFC h GJ 22

DE F1145PC5 3x400V Brauchwasserspeicher Wärmepumpentyp NiedrigtemperaturWärmepumpe Integrierte Elektroheizpatrone für Zusatzheizung Wärmepumpe für Heizung und Brauchwasser Klima Temperatureignung Geltende Normen Abgegebene Nennheizleistung Prated Luft/Wasser Abluft/Wasser Flüssigkeit/Wasser Wasser/Wasser Nein Nein Nein Mittel Kalt Warm Mittel (55) EN14825 & EN16147 Deklarierte Kapazität für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 5,0 3,5 4,1 4,3 4,6 3,8 3,2 Niedrig (35) Mittlerer Saisonwirkungsgrad für Raumerwärmung ƞ s 128 Deklarierter COP für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 2,99 3,57 3,84 4,04 3,26 2,74 Bivalenztemperatur Kapazität bei zyklischem Betrieb Abbaukoeffizient T biv Pcych Cdh 3,9 0,99 Min. Außenlufttemperatur COP bei zyklischem Betrieb Max. Vorlauftemperatur TOL COPcyc WTOL 10 65 Leistungsaufnahme in anderen Stellungen als der aktiven Stellung Ausgeschaltete Stellung P OFF 0,002 Thermostat ausgeschaltete Stellung P TO 0,008 StandbyModus P SB 0,007 Kurbelgehäuseheizermodus P CK 0,012 Zusatzheizung Nennheizleistung Typ der zugeführten Energie Psup 1,8 Elektrisch Sonstige Posten Kapazitätsregelung Schallleistungspegel, Innen/Außenbereich hresenergieverbrauch L WA Q HE Fest 43 / 3 027 h Nomineller Luftvolumenstrom (LuftWasser) Nennfluss Wärmeträger Volumenstrom Wärmequellenmedium Flüssigkeit/Wasser oder Wasser/WasserWärmepumpen 0,35 0,62 Für Wärmepumpe mit Raumerwärmung und Brauchwasserbereitung Deklariertes Verbrauchsprofil Brauchwasserbereitung Täglicher Energieverbrauch hresenergieverbrauch Q elec AEC 9,73 h h Energieeffizienz Brauchwasserbereitung Tagesbrennstoffverbrauch hresbrennstoffverbrauch ƞ wh Q fuel AFC h GJ 23

DE F1145PC6 3x400V Brauchwasserspeicher Wärmepumpentyp NiedrigtemperaturWärmepumpe Integrierte Elektroheizpatrone für Zusatzheizung Wärmepumpe für Heizung und Brauchwasser Klima Temperatureignung Geltende Normen Abgegebene Nennheizleistung Prated Luft/Wasser Abluft/Wasser Flüssigkeit/Wasser Wasser/Wasser Nein Nein Nein Mittel Kalt Warm Mittel (55) EN14825 & EN16147 Deklarierte Kapazität für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 6,0 4,8 5,3 5,6 6,0 4,9 4,5 Niedrig (35) Mittlerer Saisonwirkungsgrad für Raumerwärmung ƞ s 137 Deklarierter COP für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 3,18 3,69 4,02 4,29 3,30 2,96 Bivalenztemperatur Kapazität bei zyklischem Betrieb Abbaukoeffizient T biv Pcych Cdh 5,3 0,99 Min. Außenlufttemperatur COP bei zyklischem Betrieb Max. Vorlauftemperatur TOL COPcyc WTOL 10 65 Leistungsaufnahme in anderen Stellungen als der aktiven Stellung Ausgeschaltete Stellung P OFF 0,002 Thermostat ausgeschaltete Stellung P TO 0,010 StandbyModus P SB 0,007 Kurbelgehäuseheizermodus P CK 0,014 Zusatzheizung Nennheizleistung Typ der zugeführten Energie Psup 1,5 Elektrisch Sonstige Posten Kapazitätsregelung Schallleistungspegel, Innen/Außenbereich hresenergieverbrauch L WA Q HE Fest 43 / 3 425 h Nomineller Luftvolumenstrom (LuftWasser) Nennfluss Wärmeträger Volumenstrom Wärmequellenmedium Flüssigkeit/Wasser oder Wasser/WasserWärmepumpen 0,49 0,90 Für Wärmepumpe mit Raumerwärmung und Brauchwasserbereitung Deklariertes Verbrauchsprofil Brauchwasserbereitung Täglicher Energieverbrauch hresenergieverbrauch Q elec AEC 9,22 2 025 h h Energieeffizienz Brauchwasserbereitung Tagesbrennstoffverbrauch hresbrennstoffverbrauch ƞ wh Q fuel AFC 106 h GJ 24

DE F1145PC8 3x400V Brauchwasserspeicher Wärmepumpentyp NiedrigtemperaturWärmepumpe Integrierte Elektroheizpatrone für Zusatzheizung Wärmepumpe für Heizung und Brauchwasser Klima Temperatureignung Geltende Normen Abgegebene Nennheizleistung Prated Luft/Wasser Abluft/Wasser Flüssigkeit/Wasser Wasser/Wasser Nein Nein Nein Mittel Kalt Warm Mittel (55) EN14825 & EN16147 Deklarierte Kapazität für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 8,0 6,2 6,9 7,2 7,6 6,4 5,9 Niedrig (35) Mittlerer Saisonwirkungsgrad für Raumerwärmung ƞ s 141 Deklarierter COP für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 3,28 3,81 4,13 4,41 3,44 3,07 Bivalenztemperatur Kapazität bei zyklischem Betrieb Abbaukoeffizient T biv Pcych Cdh 4,9 0,99 Min. Außenlufttemperatur COP bei zyklischem Betrieb Max. Vorlauftemperatur TOL COPcyc WTOL 10 65 Leistungsaufnahme in anderen Stellungen als der aktiven Stellung Ausgeschaltete Stellung P OFF 0,002 Thermostat ausgeschaltete Stellung P TO 0,012 StandbyModus P SB 0,007 Kurbelgehäuseheizermodus P CK 0,014 Zusatzheizung Nennheizleistung Typ der zugeführten Energie Psup 2,1 Elektrisch Sonstige Posten Kapazitätsregelung Schallleistungspegel, Innen/Außenbereich hresenergieverbrauch L WA Q HE Fest 45 / 4 433 h Nomineller Luftvolumenstrom (LuftWasser) Nennfluss Wärmeträger Volumenstrom Wärmequellenmedium Flüssigkeit/Wasser oder Wasser/WasserWärmepumpen 0,64 1,20 Für Wärmepumpe mit Raumerwärmung und Brauchwasserbereitung Deklariertes Verbrauchsprofil Brauchwasserbereitung Täglicher Energieverbrauch hresenergieverbrauch Q elec AEC 9,09 1 995 h h Energieeffizienz Brauchwasserbereitung Tagesbrennstoffverbrauch hresbrennstoffverbrauch ƞ wh Q fuel AFC 108 h GJ 25

DE F1145PC10 3x400V Brauchwasserspeicher Wärmepumpentyp NiedrigtemperaturWärmepumpe Integrierte Elektroheizpatrone für Zusatzheizung Wärmepumpe für Heizung und Brauchwasser Klima Temperatureignung Geltende Normen Abgegebene Nennheizleistung Prated Luft/Wasser Abluft/Wasser Flüssigkeit/Wasser Wasser/Wasser Nein Nein Nein Mittel Kalt Warm Mittel (55) EN14825 & EN16147 10,0 Deklarierte Kapazität für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 7,9 8,7 9,2 9,6 8,2 7,6 Niedrig (35) Mittlerer Saisonwirkungsgrad für Raumerwärmung ƞ s 147 Deklarierter COP für Raumerwärmung bei Teillast und Außenlufttemperatur = 7 = +2 = +7 = +12 = 15 (wenn TOL < 20) 3,40 3,91 4,25 4,58 3,52 3,19 Bivalenztemperatur Kapazität bei zyklischem Betrieb Abbaukoeffizient T biv Pcych Cdh 5,2 1,00 Min. Außenlufttemperatur COP bei zyklischem Betrieb Max. Vorlauftemperatur TOL COPcyc WTOL 10 65 Leistungsaufnahme in anderen Stellungen als der aktiven Stellung Ausgeschaltete Stellung P OFF 0,002 Thermostat ausgeschaltete Stellung P TO 0,010 StandbyModus P SB 0,007 Kurbelgehäuseheizermodus P CK 0,014 Zusatzheizung Nennheizleistung Typ der zugeführten Energie Psup 2,4 Elektrisch Sonstige Posten Kapazitätsregelung Schallleistungspegel, Innen/Außenbereich hresenergieverbrauch L WA Q HE Fest 45 / 5 345 h Nomineller Luftvolumenstrom (LuftWasser) Nennfluss Wärmeträger Volumenstrom Wärmequellenmedium Flüssigkeit/Wasser oder Wasser/WasserWärmepumpen 0,82 1,56 Für Wärmepumpe mit Raumerwärmung und Brauchwasserbereitung Deklariertes Verbrauchsprofil Brauchwasserbereitung Täglicher Energieverbrauch hresenergieverbrauch Q elec AEC 8,86 1 945 h h Energieeffizienz Brauchwasserbereitung Tagesbrennstoffverbrauch hresbrennstoffverbrauch ƞ wh Q fuel AFC 111 h GJ 26

Sakregister DE Sakregister E Energimärkning Informationsblad, 3 4 Teknisk dokumentation, 6 7 Energy labelling Information sheet, 11 12 Technical documentation, 14 15 V Wärmemengenzählung Informationsblatt, 19 20 Technische Dokumentation, 22 23 27

WS name: Gemensamt WS version: a75 (working edition) Publish date: 20150902 16:05 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE285 21 Markaryd info@nibe.se www.nibe.eu 331334