1 User Manual / Bedienungsanleitung dscr Multiswitch / Multischalter TdSCR 504/508/512 Article dscr Multiswitch Multischalter Article no. TdSCR TdSCR TdSCR Version A Date 10/2018 EN / DE

2 dscr Multiswitch TdSCR504/508/512 Product description The product is designed to support a wide range of new and existing multiswitch installations. Each unit has: 4 cascadeable LNB inputs from 1 universal Quattro LNB (VL HL VH HH) or 2 Wideband LNB (V H) 1 cascadeable terrestrial trunk input. 1 level adjuster for terrestrial signals 4, 8 or 12 SCR/Legacy outputs 1 DC input (for switch, line and LNB powering). Each output can support a wide variety of satellite receivers : In legacy mode, the outputs can be used as a standard multiswitch. In SCR mode, each output supports up to 16UBs with all versions of the single cable technology. This includes OLT, SCR, CSS, SKY UK, EN50494 and EN As all outputs are independent, the installation can be a mix of legacy and dscr connections. The terrestrial input supports any services that operate between MHz, which includes terrestrial TV, DAB and FM reception. The trunk outputs allow the cascade of multiple switches, to support large installations. The trunk outputs have a 75ohm self-termination toggle switch. If the Switch is the last in the cascade, or a standalone Switch, the toggle switch can terminate the trunk outputs without the need for 75ohm terminators. The DC power can be inserted into the switch, on the F connector, or at any point in the system. In cascaded systems, multiple power supplies might be required. 1 EN

3 dscr Multiswitch TdSCR504/508/512 Switch Installation The equipment should be mounted in a well-ventilated area. Connect the power supply to the switch, and switch on. When connected, a green LED on the front of the switch should be lit. No powering from the Set Top Box is required. The power supply can feed up to 4 Multiswitches (4 x 4 outputs). All four Satellite trunks have DC available on inputs and outputs, except if the switch is used as a terminated unit. There is no power on the Terrestrial trunk line. All unused dscr/legacy (Tap) outputs should be terminated with a 75-Ohm terminator to maintain good terrestrial signals. All trunk outputs can be cascaded. If the switch serves as a terminated unit, turn on the switch marked terminate line outputs. Configuration of the Switch Terrestrial amplifier The Terrestrial trunk has an integrated amplifier, with unity gain on the dscr output, that can be attenuated by up to 20dB. Satellite input The Satellite input level to the switch, should be between 70dBuV and 100dBuV. There is no adjustment required, as the switch has Automatic Gain Control (AGC) within this dynamic range. Input Modes: Quattro and Wideband The input connections on the product can be configured in either Quattro mode or Wideband mode. When using Quattro LNBs, the toggle switch on the top right hand side of each Switch should be set in the upper position (Quattro LNB). The Switch will then expect to receive, on each of the 4 inputs, a satellite signal from 950 to 2150MHz (Horizontal/Vertical High and Low band). When using wideband LNBs, the toggle switch, on the top right hand side of each Switch should be set in the lower position (Wideband LNB). In this case, wideband satellite signals from 290 to 2340MHz should be used (Vertical and Horizontal). In this mode, 2 wideband LNBs can be connected, for signal reception from 2 orbital positions. The left wideband inputs V-H are the DiSEqC position LNB A, and the right V-H inputs are the DiSEqC position LNB B. EN 2

4 dscr Multiswitch TdSCR504/508/512 V Sat B V Sat A H Sat B H Sat A Terr Note: when using the product in wideband mode, the product will automatically make the translation between the input frequency and the output frequency. For example a STB tunes to Horizontal High band, the product will convert the incoming horizontal band MHz into the output range between MHz. The same is true when using the product as a Wideband dscr multiswitch. If the STB tunes to a Vertical Low band channel, 1000MHz for example, the multiswitch will take the incoming vertical transponder at 340MHz and convert to Sat IF 1000MHz and output to one of the dscr output user bands. The diagram above shows the basic frequency relation between wideband satellite frequencies and the standard legacy satellite frequencies. Output: Legacy and dscr Independent of the selected input mode, the outputs can support legacy and SCR/dSCR Set Top Boxes. At start up, the Switch output works in Legacy mode and can be used as a universal, or a 2 x wideband multiswitch, depending on the position of the toggle switch. When receiving the first dscr command, the unit will automatically switch into dscr mode and supports the following standards: 3 EN

5 dscr Multiswitch TdSCR504/508/512 Sky UK standard for SkyQ STB s SkyQ STB s support 16 userbands EN50494/SCR standard (DiSEqC 1.0) STB s that only support EN50494 will only be able to use the first 4 user bands. EN50607/dCSS/dSCR standard (DiSEqC 2.0) STBs that support the newer EN50607 will be able to use all user bands (UB1 through UB16). This is typical for new multituner STBs. To return back to legacy mode, the output has to be reset. This can be done by removing the DC from the output connector, disconnecting the power from the STB. Supported output User Bands and Frequencies EN 4

6 dscr Multiswitch TdSCR504/508/512 Technical Specifications TdSCR504 Triax Unit Specification Part No Inputs - 4 SAT (1x quattro or 2 x wideband) + 1 TERR User outputs - 4 Outputs with 16 User bands Impedance inputs- / outputs Ohm 75 Frequency range SAT: dcss, Legacy MHz MHz Wideband Frequency range terr. MHz , active Input power / dcss / Legacy dbm -38 to -8 Output power dcss / Legacy dbuv 85 (AGC) (-25 dbm) Insertion loss terr. db Typ. 0 Attenuation terr. db 0 to 20 Max. Output power terr. dbuv 90 Through loss SAT db Typ Through loss terr. db Typ. -4 Isolation H/V db 25 Return loss Inputs / Outputs db 10 User band frequencies MHz SKY UK, EN50607, EN50494 (automatic selection) LNB supply voltage V 15 20v Max. LNB supply current ma 1000 Current consumption ma < External PSU V Yes (15-20) Dimension (LxBxH) mm 166 x 136 x 52 Weight g 520 Operating temperature range C -20 to +50 DC connector type - F-Connector 5 EN

7 dscr Multiswitch TdSCR504/508/512 TdSCR508 Triax Part No Unit Specification Inputs - 4 SAT (1x quattro or 2 x wideband) + 1 TERR User outputs - 8 Outputs with 16 User bands Impedance inputs- / outputs Ohm 75 Frequency range SAT: dcss, Legacy Wideband MHz MHz Frequency range terr. MHz , active Input power / dcss / Legacy dbm -38 to -8 Output power dcss / Legacy dbuv 85 (AGC) (-25 dbm) Insertion loss terr. db Typ. 0 Attenuation terr. db 0 to 20 Max. Output power terr. dbuv 90 Through loss SAT db Typ. -3 Through loss terr. db Typ. -5 Isolation H/V db 25 Return loss Inputs / Outputs db 10 User band frequencies MHz SKY UK, EN50607, EN50494 (automatic selection) LNB supply voltage V 15 20v Max. LNB supply current ma 1000 Current consumption ma < External PSU V Yes (15-20) Dimension (LxBxH) mm 166 x 237 x 52 Weight g 980 Operating temperature range C -20 to +50 DC connector type - F-Connector EN 6

8 dscr Multiswitch TdSCR504/508/512 TdSCR512 Triax Part No Unit Specification Inputs - 4 SAT (1x quattro or 2 x wideband) + 1 TERR User outputs - 12 Outputs with 16 User bands Impedance inputs- / outputs Ohm 75 Frequency range SAT: dcss, Legacy Wideband MHz MHz Frequency range terr. MHz , active Input power / dcss / Legacy dbm -38 to -8 Output power dcss / Legacy dbuv 85 (AGC) (-25 dbm) Insertion loss terr. db Typ. 0 Attenuation terr. db 0 to 20 Max. Output power terr. dbuv 90 Through loss SAT db Typ -4 Through loss terr. db Typ. -6 Isolation H/V db 25 Return loss Inputs / Outputs db 10 User band frequencies MHz SKY UK, EN50607, EN50494 (automatic selection) LNB supply voltage V 15 20v Max. LNB supply current ma 1000 Current consumption ma < External PSU V Yes (15-20) Dimension (LxBxH) mm 166 x 335 x 52 Weight g 1440 Operating temperature range C -20 to +50 DC connector type - F-Connector 7 EN

9 Bedienungsanleitung TdSCR 504/508/512 Artikel Art.-Nr TdSCR 504/508/ Version B Datum 10/2018 DE

10 Vorwort Vor der Installation und Inbetriebnahme des Produktes, lesen Sie bitte die folgenden Anweisungen. Wir empfehlen Ihnen, diese Anleitung zu behalten für die zukünftige Verwendung. Garantie Die gesetzliche Gewährleistung nach Paragraph 437 BGB beträgt 24 Monate. Bei unsachgemäßer Installation und Handhabung erlischt jeglicher Garantieanspruch. Die Montage und Inbetriebnahme darf nur von eingewiesenen Personen, Technikern oder Installateuren unter Beachtung der Sicherheitsbestimmungen durchgeführt werden. Schäden durch falsche Montage und Inbetriebnahme sowie durch unsachgemäße Handhabung führen zum Erlöschen des Garantieanspruchs. Installationsort Das Produkt wird auf eine Wand oder eine andere schwer brennbare Oberfläche montiert. Montieren Sie das Produkt an einem trockenen Ort, an dem es weder Regen noch Wasser ausgesetzt ist. Stellen Sie das Gerät nicht in die Nähe von Wärmequellen oder an Orten mit direkter Sonneneinstrahlung. Der Installationsort sollte gut belüftet sein. Hinweise Verwenden Sie fernspeisetauglicher Antennendosen. Geeignete Triax-Typen sind z.b. GDS 08 F / GDS 11 F / GDA 313 F / GAD 410 S / GAD 414 S (Durchgangsdosen) oder EDA 302 F / GAD 404 S / GAD 407 S (Einzeldose).Verwenden Sie für den Abschluss eines Stamms an der letzten Durchgangsdose Abschlusswiderstände mit kapazitiver Trennung, z.b. R 77 DCB Sicherheit Öffnen Sie niemals ein angeschlossenes Produkt: elektrische Schockgefahr. Arbeiten Sie niemals an Multischalter, Fernseher oder anderen angeschlossenen Geräten während oder kurz vor einem Gewitter: Ein Blitzeinschlag in die Antenne kann dazu führen, dass gefährliche Spannungen geführt werden. Stellen Sie sicher, dass das lokale Stromnetz der Betriebsspannung des AC/DC-Adapters entspricht. Wenn der Multischalter in Kontakt mit Flüssigkeit gekommen ist, muss er vom Netz getrennt werden. CE-Kennzeichnung Das Gerät ist mit dem CE-Zeichen gekennzeichnet und entspricht den wesentlichen Anforderungen der Europäischen Richtlinien. 2

11 Produkteigenschaften: Die TdSCR Multischalter-Serie wurde entwickelt, um eine breite Palette von neuen und bestehenden Multiswitch- Installationen zu unterstützen. 4 kaskadierbare LNB-Eingänge für 1 universal Quattro LNB (VL HL VH HH) oder 2 Breitband-LNBs, für die Umsetzung von 2 Satelliten. (V H) 4, 8 oder 12 SCR/Legacy-Ausgänge Kaskadierbarer, aktiver terrestrischer Eingang mit 20 db Pegelsteller einheitlicher Ausgangspegel durch AGC (nur SCR/dCSS) Pegelsteller für terrestrische Signale (0-20 db) Automatische Erkennung Legacy/dSCR DC-Eingang (für Schalter- und LNB-Versorgung) 75 Ohm Selbstabschluss über Stellschalter Jeder Ausgang kann eine Vielzahl von Teilnehmer versorgen: Im Legacy-Modus können die Ausgänge als Standard-Multischalter verwendet werden. Im SCR-Modus unterstützt jeder Ausgang bis zu 16 Userbänder kompatibel zu sämtlichen Unicable Protokollen. Dazu gehören OLT, SCR, CSS, Sky UK, EN50494 und EN Da alle Ausgänge unabhängig sind, kann die Installation eine Mischung aus Legacy- und dscr-verbindungen sein. Der terrestrische Eingang lässt Frequenzen von 47 und 790 MHz durch. Es lassen sich DVB-T/T2, DAB/DAB+ und UKW-Signale in die Verteilung einspeisen. Die Durchschleif-Ausgänge ermöglichen die Kaskadierung mehrerer Switches, um große Installationen umzusetzen. Die Multischalter verfügen über einen 75 Ohm Selbstabschluss. Ist der Switch der letzte in der Kaskade oder ein eigenständiger Switch, kann ein Kippschalter die Durchschleif-Ausgänge ohne den Einsatz von 75 Ohm Abschlusswiderständen abschließen. Die Spannungszuführung erfolgt über eine F-Buchse am Multischalter. In kaskadierten Systemen müssen evtl. mehrere Netzteile eingesetzt werden. 3

12 Installation Verbinden Sie die Kabel vom Quattro LNB mit den Eingangsanschlüssen LNB V/L, H/L, V/H und H/H-Eingänge (achten Sie auf die Identifizierung der Quattro-LNB-Anschlüsse). Der Multischalter ist außerdem mit einem terrestrischen Eingang ausgestattet. Schließen Sie ggf. eine terrestrische Antenne an diesen Eingang an. Das terrestrische Signal wird von den Multischaltern verstärkt und kann über einen Pegelsteller um 20 db gedämpft werden an den Teilnehmerausgängen. Bei Verwendung von Wideband LNBs muss der Stellschalter oben rechts am Gerät auf Position W gestellt werden. In diesem Modus können 2 Breitband-LNBs für den Signalempfang von 2 Orbitalpositionen angeschlossen werden. Die linken Breitbandeingänge V-H sind die DiSEqC-Position "LNB A" und die rechten V-H-Eingänge die DiSEqC-Position "LNB B". Hinweis: Wenn die/der Multischalter im Wideband-Modus betrieben werden, wird der Frequenzbereich am Ausgang automatisch auf den herkömmlichen Sat-Bereich gerechnet. Es sind keine speziellen Endgeräte erforderlich. Wenn das Gerät den Abschluss der Kaskade bildet oder als Standalone betrieben wird, stellen Sie den 75 Ohm Abschluss-Schalter auf die Position On Wenn alle Installations- und Anschlussarbeiten durchgeführt sind, kann die Spannungsversorgung am DC F-Eingang angeschlossen werden. Sobald der Multischalter mit Spannung versorgt wird, leuchtet eine grüne Status LED auf, welche den Betrieb des Gerätes signalisiert. Für den Betrieb der Multischalter wird ein externes Netzteil benötigt (TMDS ( 2030 PSU EU,, Art.-Nr ). Ein Netzteil versorgt Systeme bis zu einem Maximum von 20 Teilnehmerausgängen (kombiniert). Es werden, je nach Kaskadengröße, evtl. mehrere Netzteile benötigt. Beispiele System mit 2 x TdSCR 508 entspricht 16 Ausgängen, ein Netzteil ausreichend System mit 3 x TdSCR 508 entspricht 24 Ausgängen, zwei Netzteile erforderlich Hinweise: Der optimale Eingangspegel im Sat-Bereich liegt zwischen 70 und 95 dbuv. Da die Multischalter mit einer AGC ausgestattet sind liegt der Ausgangspegel, unabhängig vom Eingangspegel, bei ca. 85 dbuv Sollten nicht alle dscr/legacy Teilnehmer Ausgänge verwendet werden müssen Diese mit einem 75-Ohm- Abschlusswiderstand abgeschlossen werden 4

13 Unicable Einstellungen Bei Unicable Systemen ist jedem TV-Empfänger ein entsprechendes Userband mit der dazugehörigen Frequenz zuzuordnen. Dies geschieht über die Antenneneinstellungen des Endgerätes. Die vorgehensweiße kann von Gerät zu Gerät unterschiedlich sein, weshalb darauf nicht weiters eingegangen werden kann. Die Frequenzen dürfen keines Falls doppelt vergeben werden. Die TdSCR Multischalter arbeiten nach folgenden Normen: Sky UK Unterstützung von 16 Userbändern. EN50494 (SCR) Unterstützung von 4 Userbändern. EN50607 (dcss, dscr) Unterstützung von 16 Userbändern Hinweis: Das jeweilige Endgerät muss mindestens den Anforderungen der Unicable Norm EN50494 entsprechen um mit den TdSCR Multischaltern zusammen zu arbeiten. Unicable Frequenztabellen EN50494 EN50607 SKY UK IF-Kanal / Userband FREQ IF-Kanal / Userband FREQ IF-Kanal / Userband FREQ

14 Technische Spezifikationen Type: TdSCR 504 TdSCR 508 TdSCR 512 Art.-Nr Anzahl Eingänge - 4 x SAT (1x4 Quattro oder 2x2 Wideband) + 1 Terr. Teilnehmerausgänge Ausgänge je 16 Userbänder 8 Ausgänge je 16 Userbänder 12 Ausgänge je 16 Userbänder Impendanz Ohm Frequenzbereich SAT (Quattro) (Quattro) (Quattro) MHz (Wideband)* (Wideband)* (Wideband)* Frequenzbereich Terr. MHz , aktiv , aktiv , aktiv min/max Eingangspegel dbuv Ausgangspegel dscr dbuv 85 (AGC) 85 (AGC) 85 (AGC) Technische Daten Verteildämpfung Terr. db 0-20 db (regelbar) 0-20 db (regelbar) 0-20 db (regelbar) Max. Ausgangspegel Terr. dbuv Verteildämpfung SAT (Legacy) dbuv Typ. 2.5 Typ. 3 Typ. 4 Durchgangsdämpfung SAT db Typ. 2.5 Typ. 2.5 Typ. 2.5 Durchgangsdämpfung Terr. db Typ. 4 Typ. 4 Typ. 4 Entkopplung H/V db Rückflussdämpfung Eingang/Ausgang Benutzerfrequenzen db nach EN nach EN nach EN nach EN nach EN nach EN nach Sky UK 16 nach Sky UK 16 nach Sky UK LNB Spannung V V V V Stromverbrauch ma < 20V < 20V < 20V externes Netzteil (erforderlich)** V Ja (15-20V) Ja (15-20) Ja (15-20V) Mechanische Daten Abmessungen (LxBxT) mm 136x166x52 237x166x52 355x166x52 Gewicht g Betriebstemperaturbereich C -20 bis bis bis +50 Anschlusstype - F-Buchse F-Buchse F-Buchse * Frequenzbereich gilt nur Eingangsseitig. Am Ausgang wird der normale Sat-Bereich ( ) genutzt. Keine speziellen Anforderungen an die Endgeräte durch Wideband-Betrieb. ** Externes Netzteil muss separat bestellt werden (Art.-Nr ). Ein Netzteil versorgt Systeme bis zu einem Maximum von 20 Teilnehmerausgängen (kombiniert). Es werden, je nach Kaskadengröße, evtl. mehrere Netzteile benötigt. 6

15 Notes-Notizen-Notes-Notas-Notater

16 Information and manuals: Information og brugervejledninger: Information och manualer: Information und Bedienungsanleitungen: Informations et modes d emploi: Información y manuales: Lisätietoja ja oppaita: információk és útmutatók: triax.com triax.dk - triax.se - triax-gmbh.de - triax.fr - triaxmultimedia.es - triax.uk triax.at triax.hu Subject to change without notice Änderungen vorbehalten Peut être sujet à modification sans préavis Copyright 2018 TRIAX. All rights reserved. The TRIAX Logo and TRIAX Multimedia are registered trademark(s) of the TRIAX Company or its affiliates. TRIAX A/S Bjørnkærvej Hornsyld Denmark

PSG 512 A. Stromversorgung / Power supply. Betriebstemperatur / Operation temperature C

PSG 512 A. Stromversorgung / Power supply. Betriebstemperatur / Operation temperature C Multischalter Green Line A Verstärker / Amplifier B Kopfstellen / Headends C Optische Komponenten Multischalter Green Line 5 IN Endmultischalter zur Verteilung von 4 SAT-ZF- (z.b. ASTRA) und terrestrischen

Mehr

D12 Tel. +49 (0)7081 / Fax +49 (0)7081 / Quattro LNBs. Ausgänge bei Teilnehmern. Outlets to receivers

D12 Tel. +49 (0)7081 / Fax +49 (0)7081 / Quattro LNBs. Ausgänge bei Teilnehmern. Outlets to receivers A Kopfstellen Headends Green Line Multischalter 13 Eingänge Green Line Multiswitches 13 inputs B Modulatoren Modulators Quattro LNBs PAS 28113 N C Optische Geräte Optical devices PSG 1308 C Kaskaden-Multischalter

Mehr

Kaskadierbarer Unicable II Multischalter mit terrestrischen Eingang und 4 Ausgänge für Sky dscr / SatCR oder Legacy + terrestrischen Signal

Kaskadierbarer Unicable II Multischalter mit terrestrischen Eingang und 4 Ausgänge für Sky dscr / SatCR oder Legacy + terrestrischen Signal Kaskadierbarer Unicable II Multischalter mit terrestrischen Eingang und 4 Ausgänge für Sky dscr / SatCR oder Legacy + terrestrischen Signal Model: ISKY-UST110-CUO4O-16P Item: 5412 Dieser Multischalter

Mehr

Betriebsanleitung Operating instructions. WISI MULTISYSTEM QUICK DY / 2410 Stand alone + Kaskade DY / 2400 Stand alone + Cascade

Betriebsanleitung Operating instructions. WISI MULTISYSTEM QUICK DY / 2410 Stand alone + Kaskade DY / 2400 Stand alone + Cascade WISI MULTISYSTEM QUICK DY 64 1810 / 2410 Stand alone + Kaskade DY 64 1800 / 2400 Stand alone + Cascade DY 64 1800 / 1810 4 SAT-Eingänge + 1 TERR / 4 SAT inputs+1 TERR 1 UNICABLE-Ausgang / 1 UNICABLE output

Mehr

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch with 32 User Bands with Terrestrial input & 1 Legacy port

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch with 32 User Bands with Terrestrial input & 1 Legacy port with 32 User Bands with & 1 Legacy port : 47-862MHz For default UB frequencies: Unicable II Multiswitch 32 User Bands with & 1 Legacy port Installationsanleitung 1 2 Vielen Dank für den Kauf des Inverto

Mehr

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port with 32 User Bands with & 1 Legacy port : 47-862MHz For default UB frequencies: Unicable II Multiswitch 32 User Bands with & 1 Legacy port Installationsanleitung 1 2 Vielen Dank für den Kauf des Inverto

Mehr

Betriebsanleitung Operating instructions WISI MULTISYSTEM QUICK DY / 2410 Stand alone* + Cascade DY / 2400 Cascade

Betriebsanleitung Operating instructions WISI MULTISYSTEM QUICK DY / 2410 Stand alone* + Cascade DY / 2400 Cascade Betriebsanleitung Operating instructions WISI MULTISYSTEM QUICK DY 64 1810 / 2410 Stand alone* + Cascade DY 64 1800 / 2400 Cascade DY 64 1800-1810 4 SAT-Eingänge + 1 TERR / 4 SAT inputs+1 TERR 1 UNICABLE-Ausgang

Mehr

Kaskadierbarer Unicable II Multischalter mit terrestrischen Eingang und 4 Ausgänge für Unicable oder Legacy + terrestrischen Signal

Kaskadierbarer Unicable II Multischalter mit terrestrischen Eingang und 4 Ausgänge für Unicable oder Legacy + terrestrischen Signal Kaskadierbarer Unicable II Multischalter mit terrestrischen Eingang und 4 Ausgänge für Unicable oder Legacy + terrestrischen Signal Model: IDLU-UST110-CUO4O-32P Item: 5413 Der IDLU-UST110-CUO4O-32P ist

Mehr

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS K la vi er l ac ko p tik AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS ZA 8970 DRUCKS0682.indd 1 05.09.12 15:15 VerpAckunGsinhAlT UKW / UHF / VHF Flachantenne

Mehr

MCR 224 Mini-Unicable-Multischalter

MCR 224 Mini-Unicable-Multischalter MCR 224 Mini-Unicable-Multischalter Gebrauchsanleitung 1. Beschreibung Der Mini-Unicable-Multischalter MCR 224 versorgt zwei Satellitenreceiver oder einen Twin-Receiver mit Fernsehprogrammen von einem

Mehr

Multischalter. Multiswitches. Einkabellösungen. Single Cable Solutions

Multischalter. Multiswitches. Einkabellösungen. Single Cable Solutions Multischalter Einkabellösungen Multiswitches Single Cable Solutions PSQ-Serie Multischalter Made in Germany Neben der richtigen Planung sind zuverlässige Komponenten beim Aufbau von Multischalter-Anlagen

Mehr

Optische Verteiltechnik Optical Distribution Technology. premium-line. Optischer LNB Optical LNB

Optische Verteiltechnik Optical Distribution Technology. premium-line. Optischer LNB Optical LNB Optische Verteiltechnik Optical Distribution Technology Optischer LNB Optical LNB das Signal eines Satelliten wird in ein optisches Signal gewandelt optischer Ausgang in 30 nm-technologie 2V-Netzteil im

Mehr

Montageanleitung SUCP 516

Montageanleitung SUCP 516 Montageanleitung SUCP 516 1 Wichtige Hinweise zu Sicherheit und Montage Montage und Service sind von Elektrofachkräften durchzuführen. Anlage vor Inbetriebnahme auf Kurzschlüsse der Koaxial-Kabel prüfen.

Mehr

MCR 532 Unicable 2-Multischalter. Installationsanleitung

MCR 532 Unicable 2-Multischalter. Installationsanleitung MCR 532 Unicable 2-Multischalter Installationsanleitung 1. Inhalt 1. Inhalt 3 2. Beschreibung 4 3. Sicherheitsvorschriften 4 4. Entsorgung 4 5. Installationsort 5 6. Installation 5 6.1 Anschluss an ein

Mehr

Westfalia Bedienungsanleitung. Nr

Westfalia Bedienungsanleitung. Nr Bedienungsanleitung Nr. 107375 Bedienungsanleitung Satelliten Finder RL-TC-0101 Artikel Nr. 54 25 97 Instruction Manual Satellite Finder RL-TC-0101 Article No. 54 25 97 Benutzung Funktionsumfang Regelbare

Mehr

Montageanleitung CGSD 162 A Version B Date 04/2016 DE

Montageanleitung CGSD 162 A Version B Date 04/2016 DE Montageanleitung CGSD 162 A Model Item no. CGSD 162 A 325049 Version B Date 04/2016 DE Inhaltsver zeichnis 1 Sicherheitsvorschriften...3 2 Allgemeines...4 2.1 Lieferumfang... 4 2.2 Bedeutung der verwendeten

Mehr

DELTA Multischalter / Multiswitches

DELTA Multischalter / Multiswitches Mulitschalter Profi Line / Multiswitchers Profi Line Mit der Profi Line wurde eine Schalterlinie entwickelt, die durch ihre exzellente Mechanik und Elektronik besticht. Die Umsetzung im Druckgussgehäuse

Mehr

Modell: IDLU-UWT110-CUO1O-32PP Item: 5249

Modell: IDLU-UWT110-CUO1O-32PP Item: 5249 Programmierbarer und kaskadierbarer Unicable II Multischalter für 32 Teilnehmer mit 4 Universal/Breitband Satelliteneingängen und einem terrestrischen Eingang (AC/DC- Netzteil und Power Inserter inbegriffen)

Mehr

AMS 508 ECOswitch SAT range Frequency range [MHz] Gain [db] 2 ± 2,5

AMS 508 ECOswitch SAT range Frequency range [MHz] Gain [db] 2 ± 2,5 ASTRO Multischalter Hochwertige Kompakt-Multischalter; 4 SAT-Ebenen + Terrestrik Features Terrestrischer Eingang, UKW passiv oder aktiv zuschaltbar; zum direkten Anschluss einer Antenne Separater Pegelsteller

Mehr

Aktives Unikabelsystem Unicable Switchbox DPA 21

Aktives Unikabelsystem Unicable Switchbox DPA 21 Aktives Unikabelsystem Unicable Switchbox DPA 21 Bedienungsanleitung User Manual Version: 28.07.2011 Inhaltsverzeichnis Inhaltsverzeichnis 1 Einleitung... 3 2 Installation... 3 2.1 Anwendungsbeispiele...

Mehr

Unicable II Kaskade DPC-32 K. Anleitung

Unicable II Kaskade DPC-32 K. Anleitung Unicable II Kaskade DPC-32 K Anleitung Seite 1/7 08.03.2016 Inhaltsverzeichnis: 1 Überblick... 3 2 Beschreibung... 4 3 Anwendungsbeispiele... 4 3.1 32 TEILNEHMER AM UNICABLE AUSGANG... 4 3.2 16 TEILNEHMER

Mehr

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.

Mehr

Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-Lan Installationsvarianten Das DELTA 2.4 W-Lan System kann in verschiedenen Varianten installiert werden:

Mehr

Optischer Rückumsetzer Optical Converter OPM-CQT OPM-C4S. Bedienungsanleitung/ Operating manual V2

Optischer Rückumsetzer Optical Converter OPM-CQT OPM-C4S. Bedienungsanleitung/ Operating manual V2 Optischer Rückumsetzer Optical Converter OPM-CQT OPM-C4S Bedienungsanleitung/ Operating manual 0901858 V2 Montage- und Sicherheitsanweisungen Beschreibung Die optischen Rückumsetzer OPM-CQT und OPM-C4S

Mehr

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-LAN Installationsvarianten Das DELTA 2.4 W-LAN System kann in verschiedenen Varianten installiert werden:

Mehr

Unicable II Kaskade DPC-32 K. Anleitung

Unicable II Kaskade DPC-32 K. Anleitung Unicable II Kaskade DPC-32 K Anleitung Seite 1/7 13.01.2016 Inhaltsverzeichnis: 1 Überblick... 3 2 Beschreibung... 4 3 Anwendungsbeispiele... 4 3.1 32 TEILNEHMER AM UNICABLE AUSGANG... 4 3.2 16 TEILNEHMER

Mehr

V/L V/H H/L H/H. Satellite B D. Satellite - Input

V/L V/H H/L H/H. Satellite B D. Satellite - Input V/L V/H H/L H/H Terrestrial input Satellite A C Satellite B D Vertical Horizontal Vertical Horizontal Satellite - Input Unicable II Programmable/cascadable multiswitch with 32UB, 4 Universal/ Wideband

Mehr

Optische Rückumsetzer Optical Converter OPM-QTS OPM-QMS. Bedienungsanleitung/ Operating manual V2

Optische Rückumsetzer Optical Converter OPM-QTS OPM-QMS. Bedienungsanleitung/ Operating manual V2 Optische Rückumsetzer Optical Converter OPM-QTS OPM-QMS Bedienungsanleitung/ Operating manual 0901734 V2 Beschreibung Die optischen Rückumsetzer OPM-QTS und OPM-QMS von Polytron, wandeln ein optisches

Mehr

Optischer Rückumsetzer Zirkular Optical Converter Circular OPM-CDL. Bedienungsanleitung/ Operating manual

Optischer Rückumsetzer Zirkular Optical Converter Circular OPM-CDL. Bedienungsanleitung/ Operating manual Optischer Rückumsetzer Zirkular Optical Converter Circular OPM-CDL Bedienungsanleitung/ Operating manual 0901866 1 Montage- und Sicherheitshinweise 2 Beschreibung Der optische Rückumsetzer OPM-CDL von

Mehr

OPU Optischer Konverter. Betriebsanleitung

OPU Optischer Konverter. Betriebsanleitung OPU 14-03 Optischer Konverter Betriebsanleitung Betriebsanleitung OPU 14-03 Optischer Konverter Inhaltsverzeichnis 1. Produktbeschreibung... 4 1.1 Lieferumfang... 4 1.2 Anwendungsgebiete... 4 1.2.1 Grundprinzip...

Mehr

Modell: IDLU-UWT110-CUO1O-32PP Item: 5294

Modell: IDLU-UWT110-CUO1O-32PP Item: 5294 Programmierbarer und kaskadierbarer Unicable II Multischalter für 32 Teilnehmer mit 4 Universal/Breitband Satelliteneingängen und einem terrestrischen Eingang (AC/DC- Netzteil und Power Inserter inbegriffen)

Mehr

SY-720SC. SCART to HDMI Scaler OPERATION MANUAL

SY-720SC. SCART to HDMI Scaler OPERATION MANUAL SY-720SC SCART to HDMI Scaler OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 1 4.1 Scart Pinout Configuration 2 5. Connection

Mehr

HG BK-Hausanschlussverstärker CATV-Home Distribution Amplifier. Bedienungsanleitung/ Operating manual V5 KDG C(4.3)

HG BK-Hausanschlussverstärker CATV-Home Distribution Amplifier. Bedienungsanleitung/ Operating manual V5 KDG C(4.3) BK-Hausanschlussverstärker CATV-Home Distribution Amplifier HG 40125 Polytron-Vertrieb GmbH Langwiesenweg 64-71 75323 Bad Wildbad, Germany KDG C(4.3) Bedienungsanleitung/ Operating manual 0901759 V5 Montage-

Mehr

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL AU-D2 Coaxial/Optical Audio Converter OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Input Panel Diagram 2 3.2 Output Panel Diagram 2 3.3 Switcher

Mehr

SATELLITE MULTISWITCH

SATELLITE MULTISWITCH SATELLITE MULTISWITCH Bedienungsanleitung F MULTI 15 FMULTI5_Manual-de_99.indd 1 08.11.2013 12:11:29 ! Achtung! Lesen Sie die Bedienungsanleitung vollständig und sorgfältig durch. Es ist Bestandteil des

Mehr

Multischalter. Multiswitches. PSC Serie GREEN LINE. PSC series D02

Multischalter. Multiswitches. PSC Serie GREEN LINE. PSC series D02 Multischalter Die Multischalter-Serie von POLYTRON umfasst hochwertige Standalone - und Kaskaden-Multischalter sowie dazu passende Verstärker. Mit den POLYTRON Multischaltern lassen sich leistungsfähige

Mehr

OPU OPU Optische Konverter. Betriebsanleitung

OPU OPU Optische Konverter. Betriebsanleitung OPU 14-03 OPU 15-00 Optische Konverter Betriebsanleitung Betriebsanleitung OPU 14-03 OPU 15-00 Optische Konverter Inhaltsverzeichnis 1. Produktbeschreibung... 4 1.1 Lieferumfang... 4 1.2 Anwendungsgebiete...

Mehr

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.

Mehr

EL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL

EL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL EL-21SY 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 2 4.1 Front Panel Diagram 2 4.2 Rear

Mehr

Anwendungsbeispiele Verstärker Application Examples Amplifiers

Anwendungsbeispiele Verstärker Application Examples Amplifiers Anwendungsbeispiele Verstärker Application Examples Amplifiers Anwendungsbeispiele Application examples Multimedia-Verteilung in Sternstruktur über Abzweiger Multimedia distribution in star structure

Mehr

FMU 584 FMU 544 Einkabel-Multischalter. Bedienungsanleitung

FMU 584 FMU 544 Einkabel-Multischalter. Bedienungsanleitung FMU 584 FMU 544 Einkabel-Multischalter Bedienungsanleitung HINWEIS Lesen Sie die Sicherheits- und Montagehinweise sorgfältig durch, bevor Sie das Gerät anschließen oder einstellen. Eine gegebenenfalls

Mehr

Multischalter 5 Eingänge

Multischalter 5 Eingänge 2011 Verteiltechnik benötigen Sie immer dann, wenn von Ihrem Satellitenspiegel mehr als 4 Empfangsgeräte (TV, Video) unabhängig voneinander versorgt werden sollen. Durch einen Kaskadenaufbau können so

Mehr

Sampling Rate / Sample rate. Modulation (gem. DVB-Standard) Modulation (DVB standard) 16 QAM 256 QAM QPSK, 16 QAM, 64 QAM

Sampling Rate / Sample rate. Modulation (gem. DVB-Standard) Modulation (DVB standard) 16 QAM 256 QAM QPSK, 16 QAM, 64 QAM -Modulatoren modulators 1x in oder DVB-T Modulator zur Umsetzung eines -Signals in einen Kanal (QAM) oder in einen DVB-T Kanal (COFDM). Die Ausgangsmodulation kann über das Menü eingestellt werden. Der

Mehr

Installationsbeispiele Application examples

Installationsbeispiele Application examples Installationsbeispiele Application examples SPU 48-01 Z. B. zum Empfang von ASTRA für 8 Teilnehmer. E. g. for reception of ASTRA for 8 subscribers. Seite 94 Page 94 SPU 54-05 Z. B. zum Empfang von ASTRA

Mehr

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL AU-D21 Digital Audio Optical Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Front Panel Diagram 2 3.2 Rear Panel Diagram 2 3.3 Side

Mehr

Alpha 2T EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Alpha 2T EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Alpha 2T EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation der Antennenanlage Alpha 2T Die Antennenanlage Alpha 2T besteht aus der Antenne Alpha 2T und dem Antennenverteiler DB1C. Standort der Antenne

Mehr

OCO 2-00 Optisches LNB-Set. Betriebsanleitung

OCO 2-00 Optisches LNB-Set. Betriebsanleitung OCO 2-00 Optisches LNB-Set Betriebsanleitung Betriebsanleitung OCO 2-00 Optisches LNB-Set Inhaltsverzeichnis 1. Produktbeschreibung... 4 1.1. Lieferumfang... 4 1.2. Anwendungsgebiete... 5 1.2.1. Grundprinzip...

Mehr

In-Line Verstärker Green Line

In-Line Verstärker Green Line In-Line Verstärker Green Line In-line Verstärker 5, 9 Eingänge Die Verstärker PSG 505 AMP, PSG 909 AMP wurden speziell für die Multischalter der Green Line entwickelt. Jeder Eingang (TERR+SAT) ist mit

Mehr

Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna

Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna Beschreibung: Die STLP 9129 ist eine gestockte Log.-Per.- Breitband Antenne für Störfestigkeitsprüfungen im Frequenzbereich von

Mehr

SCA SCA Bedienungsanleitung Operating manual

SCA SCA Bedienungsanleitung Operating manual SAT-Einkabel-Multischalter SAT-SCR-Multiswitch 5 / 9 in 8x4 Userbänder und Terrestrik 5 / 9 in 8x4 user bands and terrestrial SCA 508-4 SCA 908-4 Bedienungsanleitung Operating manual 0901965 V1 1 HINWEIS

Mehr

Polytron universal kopfstelle

Polytron universal kopfstelle Triple-Tuner: Eingangssignale x Steckplätze Triple-Tuner: MPEG und MPEG kompatibel Eingangssignale x Ausgangssignal Steckplätze umschaltbar MPEG und MPEG kompatibel Ausgangskanäle frei zwischen -8 MHz

Mehr

E - Mail: Telefon: + 49 (0) Fax: + 49 (0) Byk - Gulden - Str. 22 D Singen

E - Mail:  Telefon: + 49 (0) Fax: + 49 (0) Byk - Gulden - Str. 22 D Singen Specifications and design are subject to change due to our policy of continual technical improvement. 104134/ 06.14 Electrical and electronic equipment are not household waste. In accordance with the European

Mehr

ANGA COM News TSH 1-G COFDM - QAM. AV - PAL Quattro

ANGA COM News TSH 1-G COFDM - QAM. AV - PAL Quattro TSH 1-G COFDM - QAM ANGA COM News AV - PAL Quattro Neue Multischalter Serie Techno Line New Multiswitch Series Techno Line 4 SAT-ZF Ebenen 1 Terr. bis 8 Teilnehmer 4 SAT-IF Polarisations 1 Terr. up to

Mehr

INDEX. 3. Package Contents Connection and Operation...4

INDEX. 3. Package Contents Connection and Operation...4 3 - P O R T H D M I S w i t c h V i s i o n 3 3 2 7 0 3 INDEX 1. I n t r o d u c t i o n... 2 2. S p e c i f i c a t i o n s... 3 3. Package Contents...3 4. P a n e l D e s c r i p t i o n s.. 4 5. Connection

Mehr

Intelligente Verteiltechnik und Erweiterung bestehender Anlagen

Intelligente Verteiltechnik und Erweiterung bestehender Anlagen Intelligente Verteiltechnik und Erweiterung bestehender Anlagen Verteiler und LNB EN0 und EN00 info@.org www..org SCR-T und SCR-T Abb.: SCR-T Bei den SCR-T und SCR-T handelt es sich Allrounder in Sachen

Mehr

MBNLED Wheel Control RGB DMX. User Manual Bedienungsanleitung

MBNLED Wheel Control RGB DMX. User Manual Bedienungsanleitung MBNLED Wheel Control RGB DMX User Manual Bedienungsanleitung Product features and benefits Esthetical designed easy to use RGB controller Use the Wheel for static colour selection, dimming, bouncing between

Mehr

Unikabel Multischalter DPA98 / DPA989. Bedienungsanleitung. Stand smart DPA 98 / DPA 989 DE 1

Unikabel Multischalter DPA98 / DPA989. Bedienungsanleitung. Stand smart DPA 98 / DPA 989 DE 1 Unikabel Multischalter DPA98 / DPA989 Bedienungsanleitung Stand 11.02.2010 smart DPA 98 / DPA 989 DE 1 Sicherheitshinweise Sicherheitshinweise ACHTUNG! Lesen Sie die Bedienungsanleitung aufmerksam durch,

Mehr

AU-D7. Audio Processor - Virtual 5.1 Encoder OPERATION MANUAL

AU-D7. Audio Processor - Virtual 5.1 Encoder OPERATION MANUAL AU-D7 Audio Processor - Virtual 5.1 Encoder OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Front Panel Diagram 2 3.2 Rear Panel Diagram 2 3.3

Mehr

Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung

Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung High Voltage measurement device HV3000 AC / DC / Impulse H+H High Voltage Technology www.hundh-mk.com Hochspannungsmessgerät typ HV3000

Mehr

SES SES Programmierbare Unicable II Multischalter. Betriebsanleitung

SES SES Programmierbare Unicable II Multischalter. Betriebsanleitung SES 5532-09 SES 5532-19 Programmierbare Unicable II Multischalter Betriebsanleitung Betriebsanleitung SES 5532-09 SES 5532-19 Programmierbare Unicable II Multischalter Inhaltsverzeichnis 1. Produktbeschreibung...

Mehr

AU-D4. Analogue to Digital Audio Converter OPERATION MANUAL

AU-D4. Analogue to Digital Audio Converter OPERATION MANUAL AU-D4 Analogue to Digital Audio Converter OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 2 4.1 Front Panel Diagram 2 4.2 Rear

Mehr

Betriebsarten-Umschalter Common mode / Differential mode switch

Betriebsarten-Umschalter Common mode / Differential mode switch Betriebsarten-Umschalter Common mode / Differential mode switch Beschreibung: Der Betriebsarten-Umschalter CMDM 87 erweitert die Messmöglichkeiten zweier V-Netznachbildungen um die einer T- und Delta-Netznachbildung.

Mehr

UKW-Verstärker CGA

UKW-Verstärker CGA UKW-Verstärker Model Item no. CGA 225 325030 Version 05-2009 DE triax.com Inhaltsverzeichnis 1 Sicherheitsvorschriften...3 2 Allgemeines...3 2.1 Lieferumfang...3 2.2 Bedeutung der verwendeten Symbolik...3

Mehr

Montageanleitung. DUO / RGB DUO / RGB RECEIVER SLIM CLIP

Montageanleitung.  DUO / RGB DUO / RGB RECEIVER SLIM CLIP Montageanleitung www.eurofer.de DUO / RGB DUO / RGB RECEIVER SLIM CLIP BEDIENUNGSANLEITUNG // INSTRUCTION MANUAL KOPPLUNG // PAIRING CONTROLLER & RECEIVER MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION MONTAGEANLEITUNG

Mehr

E - Mail: Telefon: + 49 (0) Fax: + 49 (0) Byk - Gulden - Str. 22 D Singen

E - Mail:  Telefon: + 49 (0) Fax: + 49 (0) Byk - Gulden - Str. 22 D Singen Specifications and design are subject to change due to our policy of continual technical improvement. 104134/ 09.16 Electrionic devices are not household waste but rather must be disposed of properly in

Mehr

SAT-ZF-Verteiltechnik

SAT-ZF-Verteiltechnik SAT-ZF-Verteiltechnik Multischalter- und Einkabel-Multischalter für 1, 2, 3 oder 4 SAT-Positionen Kaskadierbar Große Produktpalette Multimediatauglich Einkabel gemäß EN 50607, kompatibel mit EN 50494 Immer

Mehr

SES Programmierbarer Unicable II Multischalter. Betriebsanleitung

SES Programmierbarer Unicable II Multischalter. Betriebsanleitung SES 5532-19 Programmierbarer Unicable II Multischalter Betriebsanleitung Betriebsanleitung SES 5532-19 Programmierbarer Unicable II Multischalter Inhaltsverzeichnis 1. Produktbeschreibung... 4 1.1. Allgemeines...

Mehr

IR RECEIVER Bedienungsanleitung User s Manual

IR RECEIVER Bedienungsanleitung User s Manual Bedienungsanleitung User s Manual Die zweite Generation des MBNLED RGB DMX POWER SUPPLY und des MBNLED PRO Controller RGB DMX bieten die Möglichkeit, LED Module über eine Infrarot Fernbedienung zu steuern.

Mehr

miditech 4merge 4-fach MIDI Merger mit :

miditech 4merge 4-fach MIDI Merger mit : miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse

Mehr

JX3-PS1. Installationsanleitung. Version Lieferumfang

JX3-PS1. Installationsanleitung. Version Lieferumfang JX3-PS1 Spannungsversorgungsmodul Jetter AG Kontakte: Gräterstraße 2 E-Mail - Vertrieb: sales@jetter.de D-71642 Ludwigsburg E-Mail - Hotline: hotline@jetter.de Germany Telefon - Hotline: +49(0)7141/2550-444

Mehr

TracVision - Update der Tracking Frequenzen

TracVision - Update der Tracking Frequenzen TracVision - Update der Tracking Frequenzen - 18.04.2011 Betrifft alle TracVision-Antennen mit der Einstellung HOTBIRD Am 18.04.2011 wurde die Tracking-Frequenz 11862 MHz auf Hotbird geändert. Dies betrifft

Mehr

OPU 14-00/-01 OPU 15-00

OPU 14-00/-01 OPU 15-00 OPU 14-00/-01 OPU 15-00 BETRIEBSANLEITUNG Optische Konverter DE Lesen und aufbewahren FR/NL www.axing.com Download Betriebsanleitung OPU 14-0x/15-00 Allgemeines Sicherheitshinweise Beachten Sie die folgenden

Mehr

UWC 8801 / 8802 / 8803

UWC 8801 / 8802 / 8803 Wandbedieneinheit Wall Panel UWC 8801 / 8802 / 8803 Bedienungsanleitung User Manual BDA V130601DE UWC 8801 Wandbedieneinheit Anschluss Vor dem Anschluss ist der UMM 8800 unbedingt auszuschalten. Die Übertragung

Mehr

AU-D4T. Analogue to Digital Audio Converter with Audio delay OPERATION MANUAL

AU-D4T. Analogue to Digital Audio Converter with Audio delay OPERATION MANUAL AU-D4T Analogue to Digital Audio Converter with Audio delay OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 2 4.1 Front Panel

Mehr

Zehnder ComfoWell 220

Zehnder ComfoWell 220 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for

Mehr

ISN Impedanz Stabilisierungs Netzwerk für PLC Impedance Stabilization Network for PLC

ISN Impedanz Stabilisierungs Netzwerk für PLC Impedance Stabilization Network for PLC ISN 561-1 Impedanz Stabilisierungs Netzwerk für PLC Impedance Stabilization Network for PLC Beschreibung: ISN 561-1 ist ein Impedanzstabilisierungsnetzwerk (ISN) zur Messung der asymmetrischen Störspannung

Mehr

Digitale Kanalaufbereitungs System TSH 2010 Digital Channel Processing System TSH 2010 Das digitale Aufbereitungssystem TSH dient zum Aufbau von kompa

Digitale Kanalaufbereitungs System TSH 2010 Digital Channel Processing System TSH 2010 Das digitale Aufbereitungssystem TSH dient zum Aufbau von kompa Digitale Kanalaufbereitungs System TSH 2010 Digital Channel Processing System TSH 2010 Das digitale Aufbereitungssystem TSH dient zum Aufbau von kompakten Kopfstellen, die Gemeinschaftsantennenanlagen

Mehr

A04 Tel. +49 (0)7081 / Fax +49 (0)7081 /

A04 Tel. +49 (0)7081 / Fax +49 (0)7081 / Hausanschlussverstärker Die HG-Verstärker-Serie bietet Hausanschluss- und Hausverteil-Verstärker in bester POLYTRON-Qualität mit einem bis 1 GHz. Zuverlässige Komponenten und hochwertige Gehäuse untermauern

Mehr

Einkabelsystem UCP 20 / UCP 30. Anleitung

Einkabelsystem UCP 20 / UCP 30. Anleitung Einkabelsystem UCP 20 / UCP 30 Anleitung Seite 1/8 Inhaltsverzeichnis: 1 Überblick. 3 2 Beschreibung 4 3 Inbetriebnahme.. 4 3.1 VORAUSSETZUNGEN ZUR INSTALLATION.. 4 3.2 SICHERHEITSHINWEISE 5 3.3 INSTALLATION

Mehr

rot red braun brown rot red RS-8 rot red braun brown R S V~

rot red braun brown rot red RS-8 rot red braun brown R S V~ Kleiner Ring 9 /Germany Phone: 0049 4122 / 977 381 Fax: 0049 4122 / 977 382 Sample connections: Feedback module with integrated detection of occupied tracks for the RS-feedback bus (Lenz Digital plus)

Mehr

CONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP

CONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP ANLEITUNGEN // INSTRUCTIONS CONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP BEDIENUNGSANLEITUNG // INSTRUCTION MANUAL MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION KOPPLUNG

Mehr

Mit dem UniSystem präsentiert SPAUN electronic ein absolutes Novum für die. Denn... mit den System-Komponenten können - vollkommen unabhängig von einem Netzanschluss - 4, 8, 12 oder 16 SAT-ZF-Ebenen mit

Mehr

Bedienungsanleitung. User Manual

Bedienungsanleitung. User Manual Bedienungsanleitung Seite: -3 User Manual LightmaXX 5ive STAR LED LIG0009669-000 Page: 4-5 Lieber Kunde, vielen Dank das Sie sich für ein Produkt von LightmaXX entschieden haben. In der folgenden Anleitung

Mehr

Multischalter WISI MULTISYSTEM QUICK Gesamtprogramm. Schaltbeispiele

Multischalter WISI MULTISYSTEM QUICK Gesamtprogramm. Schaltbeispiele Schaltbeispiele Für UNICABLE-Lösungen ist die Verwendung der WISI Sat-Dose und des Abschlusswider stands DV 27 notwendig. Beispiel DY 64 2410, 2 x 4 Teilnehmer mit WISI Satellitenreceiver WISI MULTISYSTEM

Mehr

Datenblatt. P-series PDU 2.5/4/4AN

Datenblatt. P-series PDU 2.5/4/4AN Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means

Mehr

Satellite B or D. Satellite Inputs (LNB Trunk)

Satellite B or D. Satellite Inputs (LNB Trunk) Power Diagnosis V/L Satellite A C V/H H/L Satellite Inputs (LNB Trunk) Satellite B D 2 x Wideband LNBs (SAT A/B or C/D) Universal Quattro LNB (SAT A/B/C/D) H/H Terrestrial input On DC in 19V 3.5A max.

Mehr

Benutzerhandbuch. dcss-/dscr-multischalter 9732

Benutzerhandbuch. dcss-/dscr-multischalter 9732 Benutzerhandbuch dcss-/dscr-multischalter 9732 INHALT 1. INSTALLATION DER HARDWARE... 3 2. KONFIGURATION DES MODULS... 4 Installationsmodus... 4 CSS-Modus... 4 NUR EN50494/SCR-Standard... 4 NUR EN50607/dCSS-Standard...

Mehr

TracVision - Update der Tracking Frequenzen

TracVision - Update der Tracking Frequenzen TracVision - Update der Tracking Frequenzen - 07.01.2011 Betrifft alle TracVision-Antennen mit der Einstellung ASTRA1 Am 07.01.2011 wurde die Tracking-Frequenz 10921 MHz auf Astra 1 geändert. Dies betrifft

Mehr

Multischalter WISI MULTISYSTEM QUICK Gesamtprogramm. Schaltbeispiele

Multischalter WISI MULTISYSTEM QUICK Gesamtprogramm. Schaltbeispiele Schaltbeispiele WISI MULTISYSTEM QUICK Gesamtprogramm Für UNICABLE-Lösungen ist die Verwendung der WISI Sat-Dose und des Abschlusswider stands DV 27 notwendig. Beispiel DY 64 2410, 2 x 4 Teilnehmer mit

Mehr

Electrical tests on Bosch unit injectors

Electrical tests on Bosch unit injectors Valid for Bosch unit injectors with order numbers 0 414 700 / 0 414 701 / 0 414 702 Parts Kit Magnet*: - F00H.N37.925 - F00H.N37.933 - F00H.N37.934 * For allocation to the 10-place Bosch order number,

Mehr

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.

Mehr

TRIAX-Multischaltersysteme. Für kleine, mittlere und große Gemeinschaftsanlagen. triax-gmbh.de / triax.at

TRIAX-Multischaltersysteme. Für kleine, mittlere und große Gemeinschaftsanlagen. triax-gmbh.de / triax.at TRIAX-Multischaltersysteme Für kleine, mittlere und große Gemeinschaftsanlagen triax-gmbh.de / triax.at triax-gmbh.de / triax.at TRIAX -Multischalterlösungen Für jeden Bedarf und jede Anwendung. Empfang

Mehr

Kaskadierbare Einkabellösung. Typ: SCA 32. Einkabelanwendung (SCR / dcss)

Kaskadierbare Einkabellösung. Typ: SCA 32. Einkabelanwendung (SCR / dcss) Kaskadierbare Einkabellösung Typ: SCA 32 Einkabelanwendung (SCR / dcss) Inhaltsverzeichnis: 1 Überblick 1 2 Beschreibung 2 3 Anwendungsbeispiele 3 3.1 32 SCR-/dCSS-Teilnehmer/-Receiver am [Output 1] ->

Mehr

BK-Hausanschlussverstärker CATV-Home Distribution Amplifier HC 30/ Bedienungsanleitung/ Operating manual V3

BK-Hausanschlussverstärker CATV-Home Distribution Amplifier HC 30/ Bedienungsanleitung/ Operating manual V3 BK-Hausanschlussverstärker CATV-Home Distribution Amplifier HC 30/40125 Bedienungsanleitung/ Operating manual 0901375 V3 Montage- und Sicherheitshinweise Bedingungen zur Sicherstellung der elektromagnetischen

Mehr

TELESTAR SKYWIRE 2 HC LNB

TELESTAR SKYWIRE 2 HC LNB Gebrauchsanweisung TELESTAR SKYWIRE 2 HC LNB Sehr geehrter Kunde, vielen Dank, dass Sie Sich für dieses hochwertige Produkt entschieden haben. Sollte Ihre Antenne nicht richtig funktionieren, muss nicht

Mehr