DRUCK & TEMPERATUR LEITENBERGER GMBH DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial Pressure Transmitter DMP P Nominal pressure: from 0... 00 mbar up to 0... 40 bar Output signals: wire: 4... 0 ma / wire: 0... 0 V Special characteristics: hygienic process connections, EHEDGconformity reduced oil volume, minimises temperature influence at zero point CIP / SIP cleaning up to 50 C vacuum resistant excellent long term stability Optional versions: IS version Ex ia = intrinsically safe for gases and dusts SIL according to IEC 6508 / IEC 65 special materials as Hastelloy and Tantal cooling element for media temperatures up to 00 C customer specific versions SIL The pressure transmitter DMP P was designed for use in the food and pharmaceutical industry. The compact design with hygienic process connections makes it possible to achieve an outstanding performance in terms of accuracy, temperature behavior and long term stability. The modular construction concept allows a combination of various process connections with different filling fluids and a cooling element. Several electrical connections complete the profile of DMP P. This transmitter fulfills nearly all requirements in hygienic industrial processes. Preferred areas of use are: Food Industry Pharmacy Material and test certificates: material mill test report according to DIN EN 004.. (optional) specific test report according to DIN EN 004.. (optional) DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de
DMP P Input pressure range Nominal pressure gauge / abs. [bar] 0 0.0 0.6 0.5 0.40 0.60.6 Overpressure [bar] 5 0.5 5 5 0 Burst pressure [bar] 7.5.5.5.5 7.5 7.5 5 Nominal pressure gauge / abs. [bar].5 4 6 0 6 5 40 Overpressure [bar] 0 0 40 40 80 80 05 Burst pressure [bar] 5 5 50 50 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request consider the pressure resistance of fitting and clamps Output signal / Supply wire: 4... 0 ma / V S = 8... V DC Option IS protection wire: 4... 0 ma / V S = 0... 8 V DC Options wire wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy standard: nominal pressure < 0.4 bar : ± 0.5 % FSO nominal pressure 0.4 bar: ± 0.5 % FSO option: nominal pressure 0.4 bar: ± 0.5 % FSO Permissible load current wire: R max = [(V S V S min ) / 0.0] Ω current wire: R max = 500 Ω voltage wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time wire: < 0 msec wire: msec accuracy according to IEC 60770 limit point adjustment (non linearity, hysteresis, repeatability) Thermal effects (Offset and Span) / Permissible temperatures Nominal pressure P N [bar] 0 < 0.40 0.40 Tolerance band [% FSO] ± 0.75 ±,5 ± 0.75 in compensated range [ C] 0... 85 0... 50 0... 85 Permissible temperatures 4 medium: 40... 5 C for filling fluid silicon oil 0... 5 C for filling fluid food compatible oil electronics / environment: 40... 85 C storage: 40... 00 C Permissible temperature medium for filling fluid silicon oil overpressure: 40 00 C vacuum: 40... 50 C 5 cooling element 00 C filling fluid food compatible oil overpressure: 0... 50 C vacuum: 0... 50 C 5 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions. 4 max. temperature of the medium for nominal pressure gauge > 0 bar: 50 C for 60 minutes with a max. environmental temperature of 50 C 5 also for P abs bar Electrical protection Short circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration according to DIN EN 60068 6 Shock according to DIN EN 60068 7 Filling fluids Options Materials G /": 0 g RMS (5... 000 Hz)others except G /": 0 g RMS (5 000 Hz) G /": 500 g / msec others except G / : 00 g / msec silicon oil food compatible oil with FDA approval (Mobil DTE FM ; Category Code: H; NSF Registration No.: 066) Pressure port stainless steel.4404 (6 L) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated Seals (media wetted) standard: FKM (recommended for medium temperatures 00 C) option: FFKM (recommended for medium temperatures > 00 C) clamp and dairy pipe: without Diaphragm Media wetted parts stainless steel.445 (6 L) / Tantalum and Hastelloy C 76 (.489) on request pressure port, seals, diaphragm DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de
DMP P Explosion protection (only for 4 0 ma / wire) Approval DX 9 DMP P IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga (zone 0: II D Ex ta IIIC T 85 C, IP6x, in preparation) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh Max. temperatures for in zone 0: 0... 60 C with p atm 0.8 bar up to. bar environment in zone or higher: 0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 5 ma Weight min. 00 g (depending on process connection) Installation position any (standard calibration in a vertical position with the pressure port connection down; differing installation position for P N bar have to be specified in the order) Operational life > 00 x 0 6 pressure cycles CE conformity EMC Directive: 004/08/EC Wiring diagrams wire system (current) p supply + wire system (current / voltage) supply + p V S I supply V S I/U supply signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (only wire) Electrical connections (dimensions in mm) Binder 7 (5 pin) 4 Mx / metal (4 pin) Shield ground pin 5 4 field housing IN + IN OUT+ cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 Mx 4 pin cable outlet with PVC cable (IP 65) IP 67) (IP 67) (IP 67) 6 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 7 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 6 standard: m PVC cable without ventilation tube (permissible temperature: 5 70 C) 7 different cable types and lengths available, permissible temperature depends on kind of cable DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de
DMP P Mechanical connection (dimension in mm) Option G/" flush with ISO 4400 8 G/4" flush G" flush G/" flush G" flush with ISO 4400 with ISO 4400 with radial o ring with radial o ring G" cone dairy pipe (DIN 85) clamp (ISO 85) cooling element 00 C with ISO 4400 with ISO 4400 with ISO 4400 SIL and SIL Ex version: total length increases by 6.5 mm! metric threads and other versions on request 8 possible only for P N bar dimension in mm size DN 5 DN 40 DN 50 A 45 B 44 56 68.5 dimension in mm size DN 5 DN 8 DN 5 A 45 B 50.5 50.5 64 This This data datasheet contains product specification, properties are are not not guaranteed. Subject to to change without notice. DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de
DMP P DRUCK & TEMPERATUR LEITENBERGER GMBH Spezifikationsblatt / specification sheet DMP P - - - - - - - - - Messgröße Eingang Ausgang relativ absolut 5 0 0 5 0 [bar] 0,0 0 0 0 0,6 6 0 0 0,5 5 0 0 0,40 4 0 0 0 0,60 6 0 0 0,0 0 0,6 6 0,5 5 0 4,0 4 0 0 6,0 6 0 0 0 0 0 6 6 0 5 5 0 40 4 0 0-0 X 0 Sondermessbereiche 9 9 9 4 0 ma / -Leiter 0 0 ma / -Leiter E S 0 0 V / -Leiter Ex-Schutz 4 0 ma / -Leiter SIL 4 0 ma / -Leiter SIL mit Ex-Schutz 4 0 ma / -Leiter ES Genauigkeit für P N 0,4 bar 0,5 % für P N < 0,4 bar 0,5 % 5 Option für P N 0,4 bar 0,5 % Elektrischer Anschluss Stecker und Kabeldose ISO 4400 Stecker Binder Serie 7 (5-polig) Kabelausgang mit PVC-Kabel 0 0 0 0 T A 0 Kabelausgang T R 0 Stecker Mx (4-polig) / Metall M 0 Kompakt-Feldgehäuse Edelstahl.405 8 5 0 9 9 Mechanischer Anschluss G/" mit frontbündig geschweißter Membrane (DIN 85) 4 Z 0 0 G/4" mit frontbündig geschweißter Membrane (DIN 85) Z 0 G" mit frontbündig geschweißter Membrane (DIN 85) Z G" DIN 85 mit rad. O-Ring und frontbündiger Membrane Z 5 7 G/" DIN 85 mit rad. O-Ring und frontbündiger Membrane Z 6 G " Konus K Clamp DN 5 (ISO 85) C 6 Clamp DN 8 (ISO 85) C 6 Clamp DN 5 (ISO 85) C 6 Milchrohr DN 5 (DIN 85) M 7 Milchrohr DN 40 (DIN 85) M 7 5 Milchrohr DN 50 (DIN 85) M 7 6 9 9 Trennmembrane Edelstahl.445 (6L) Tantal T auf Anfrage Hastelloy C-76 (.489) H Dichtung für Clamp oder Milchrohr: keine 0 für Zollgewinde - : FKM für Zollgewinde - Option: FFKM 7 Füllflüssigkeit Silikonöl Lebensmitteltaugliches Öl Sonderausführungen mit Temperaturentkoppler bis 00 C : m PVC-Kabel ohne Belüftungsschlauch (Temperatureinsatzbereich: -5 70 C), auf Anfrage Kabel mit Luftschlauch (Code TR0 = PVC-Kabel), Kabel in verschiedenen Ausführungen und Längen lieferbar, Temperatureinsatzbereich abhängig vom Kabel; Kabel nicht im Preis enthalten 0 0 0 0 0 9 9 Die Nutüberwurfmutter muss bei elektrischen Anschluss Feldgehäuse in Kombination mit mechanischen Anschluss Milchrohr bei der Herstellung auf dem Druckmessumformer montiert werden. Die Nutüberwurfmutter muss als separate Position bestellt werden. 4 möglich nur für P N bar DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de t entnommen werden. Technische Änderungen vorbehalten. eser Preisliste enthalten die Spezifikation der Produkte, nicht die Zusicherung von Eigenschaften. Ausführliche Informationen zu den Bestelloptionen können dem Datenblatt e Die Angaben dies