DMP 331P DRUCK & TEMPERATUR LEITENBERGER GMBH. Industrial Pressure Transmitter

Ähnliche Dokumente
DMK 331P DRUCK & TEMPERATUR LEITENBERGER GMBH. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331 DRUCK & TEMPERATUR LEITENBERGER GMBH. Industrial. Stainless Steel Sensor. Industrial. Pressure Transmitter. accuracy according to IEC 60770:

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DS 201P DS 201P DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic. Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrie- Druckmessumformer. verschweißter Edelstahlmembrane. Genauigkeit nach IEC 60770: Standard: 0,35 % FSO Option: 0,25 % FSO

DMK 331P. Industrie- Druckmessumformer. Druckanschlüsse mit frontbündig verschweißter Edelstahlmembrane. Genauigkeit nach IEC 60770: 0,5 % FSO

DMP 331P. Industrie- Druckmessumformer. Prozessanschlüsse mit frontbündig verschweißter Edelstahlmembrane

DMK 331. Industrie- Keramiksensor. Druckmessumformer. Genauigkeit nach IEC 60770: 0,5 % FSO

Anlagen- und Maschinenbau kundenspezifische Ausführungen Heizung, Lüftung, Klimatechnik

DMK 331. Industrie- Druckmessumformer. Keramiksensor. Genauigkeit nach IEC 60770: 0,5 % FSO

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

DMK 331. IndustrieDruckmessumformer. Keramiksensor. Genauigkeit nach IEC 60770: 0,5 % FSO. TEMATEC GmbH. http: //

DMP 331. Industrie- Druckmessumformer für Niederdruck. Edelstahlsensor. Genauigkeit nach IEC 60770: Standard: 0,35 % FSO Option: 0,25% / 0,1%FSO

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

DMP 333. Industrie- Druckmessumformer für Hochdruck. Edelstahlsensor. Genauigkeit nach IEC 60770: Standard: 0,35 % FSO Option: 0,25 / 0,1 % FSO

direktgesteuert direct acting

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

direktgesteuert direct acting

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...

DMP 335. Industrie Druckmessumformer. verschweißter, ölfreier Edelstahlsensor. Genauigkeit nach IEC 60770: 0,5 % FSO

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

direktgesteuert direct acting

IMK 331P. Industrie- Druckmessumformer. Druckanschlüsse mit frontbündig verschweißter Edelstahlmembrane. Genauigkeit nach IEC 60770: 0,5 % FSO

LMK 387. Edelstahl-Tauchsonde DRUCK & TEMPERATUR LEITENBERGER GMBH. Keramiksensor. Genauigkeit nach IEC 60770: Standard: 0,35 % FSO Option 0,25 % FSO

2/2-way plastic solenoid valve - Type 104

2/2-way solenoid valve - Type 239

2/2-way plastic solenoid valve - Type 110

Inhaltsverzeichnis Index

2/2-way solenoid valve - Type 218

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

LMP 307 LMP 307. Edelstahl Tauchsonde mit Edelstahlsensor. Durchmesser: 27 mm Füllstandsmessung in Wasser Heiz und Dieselöl

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

IDCT 531. Industrie- Druckmessumformer mit RS485 Modbus RTU. Edelstahlsensor. Genauigkeit nach IEC 60770: Standart: ± 0,35 % FSO Option: ± 0,25 % FSO

Technisches Datenblatt Technical Data Sheet. Drehzahlsensoren / Speed Sensors 1 Kanal Hall M14 LD Familie 1 Channel Hall M14 LD Type

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

PU-06. Features. Druckmessumformer für allgemeine industrielle Anwendungen. Beschreibung: Anwendung:

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type

DMP 331Pi. Präzisions- Druckmessumformer. Druck- und Prozessanschlüsse mit frontbündig verschweißter Edelstahlmembrane

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

DMK 457 DMK 457. Druckmessumformer für Schifffahrt und Offshore

servogesteuert pilot operated

A P max. 16bar P R max. 64bar R P max. 16bar

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

P A max. 100bar A P max. 16bar

IDG. Drehzahlsensor / Speed Sensor

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W

Technisches Datenblatt Technical Data Sheet. Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Familie 1 Channel Hall M18 Type

DCT 531. Industrie- Druckmessumformer mit RS485 Modbus RTU. Edelstahlsensor. Genauigkeit nach IEC 60770: Standart: ± 0,35 % FSO Option: ± 0,25 % FSO

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC

PU-07. Features. Druckmessumformer mit Keramiksensor Klasse 0,5. Beschreibung: Anwendung:

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

Ex emergency pull-wire switches // Ex ZS 75 S

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung

Non-incendive pressure transmitter For applications in hazardous areas Models N-10 and N-11

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung

LMK 382 LMK 382 H LMK 382 / 382 H. Edelstahl Tauchsonde mit Keramiksensor

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

Datenblatt. P-series PDU 2.5/4/4AN

~XECRO. sensing ahead NPN PNP 1/+ 1/+ NPN 4/S 4/S PNP. Data sheets are available on

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

ISLIKER MAGNETE AG - CH-8450

Tachogeneratoren. Gehäuse ø95 mm, lagerlose Ausführung GTB 9. Merkmale. Kurze Reaktionszeit Leerlaufspannung mv pro U/min

Magnetic inductive flow sensors

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V

Technisches Datenblatt Technical Data Sheet. HySense PR 509

IDS 201P. Elektronischer Druckschalter. Druckanschlüsse mit frontbündig verschweißter Edelstahlmembrane. Genauigkeit nach IEC 60770: 0,5 % FSO

IMP 331i IMP 333i ILMP 331i

Induktive Näherungsschalter inductive proximity switches

ISLIKER MAGNETE AG - CH-8450

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

DIGICONTROL- Gerätedatenblatt F-KCO2T1 2-Strahlverfahren, (nicht-dispersive Infrarot Technologie) NDIR

DS 200P DS 200P. Elektronischer Druckschalter für die Prozessindustrie. Druck- und Prozess-anschlüsse mit frontbündig verschweißter Edelstahlmembrane

Breaking load Nennlast Ln. Accuracy class Minimum division Safe load limit. Kleinster Teilungswert vmin. Genauigkeitsklasse n.

DMP 331i / DMP 333i LMP 331 i

Stahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting

Breaking load Nennlast Ln. Accuracy class Minimum division Safe load limit. Kleinster Teilungswert vmin. Genauigkeitsklasse n.

Attenuator and Distribution System Zehnder ComfoWell 220

Technisches Datenblatt Technical Data Sheet. HySense PR 130

DS 200 P. Elektronischer Druckschalter mit frontbündigem. piezoresistiver Drucksensor bis zu 4 unabhängige Schaltausgänge,

DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES

Transkript:

DRUCK & TEMPERATUR LEITENBERGER GMBH DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial Pressure Transmitter DMP P Nominal pressure: from 0... 00 mbar up to 0... 40 bar Output signals: wire: 4... 0 ma / wire: 0... 0 V Special characteristics: hygienic process connections, EHEDGconformity reduced oil volume, minimises temperature influence at zero point CIP / SIP cleaning up to 50 C vacuum resistant excellent long term stability Optional versions: IS version Ex ia = intrinsically safe for gases and dusts SIL according to IEC 6508 / IEC 65 special materials as Hastelloy and Tantal cooling element for media temperatures up to 00 C customer specific versions SIL The pressure transmitter DMP P was designed for use in the food and pharmaceutical industry. The compact design with hygienic process connections makes it possible to achieve an outstanding performance in terms of accuracy, temperature behavior and long term stability. The modular construction concept allows a combination of various process connections with different filling fluids and a cooling element. Several electrical connections complete the profile of DMP P. This transmitter fulfills nearly all requirements in hygienic industrial processes. Preferred areas of use are: Food Industry Pharmacy Material and test certificates: material mill test report according to DIN EN 004.. (optional) specific test report according to DIN EN 004.. (optional) DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de

DMP P Input pressure range Nominal pressure gauge / abs. [bar] 0 0.0 0.6 0.5 0.40 0.60.6 Overpressure [bar] 5 0.5 5 5 0 Burst pressure [bar] 7.5.5.5.5 7.5 7.5 5 Nominal pressure gauge / abs. [bar].5 4 6 0 6 5 40 Overpressure [bar] 0 0 40 40 80 80 05 Burst pressure [bar] 5 5 50 50 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request consider the pressure resistance of fitting and clamps Output signal / Supply wire: 4... 0 ma / V S = 8... V DC Option IS protection wire: 4... 0 ma / V S = 0... 8 V DC Options wire wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy standard: nominal pressure < 0.4 bar : ± 0.5 % FSO nominal pressure 0.4 bar: ± 0.5 % FSO option: nominal pressure 0.4 bar: ± 0.5 % FSO Permissible load current wire: R max = [(V S V S min ) / 0.0] Ω current wire: R max = 500 Ω voltage wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time wire: < 0 msec wire: msec accuracy according to IEC 60770 limit point adjustment (non linearity, hysteresis, repeatability) Thermal effects (Offset and Span) / Permissible temperatures Nominal pressure P N [bar] 0 < 0.40 0.40 Tolerance band [% FSO] ± 0.75 ±,5 ± 0.75 in compensated range [ C] 0... 85 0... 50 0... 85 Permissible temperatures 4 medium: 40... 5 C for filling fluid silicon oil 0... 5 C for filling fluid food compatible oil electronics / environment: 40... 85 C storage: 40... 00 C Permissible temperature medium for filling fluid silicon oil overpressure: 40 00 C vacuum: 40... 50 C 5 cooling element 00 C filling fluid food compatible oil overpressure: 0... 50 C vacuum: 0... 50 C 5 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions. 4 max. temperature of the medium for nominal pressure gauge > 0 bar: 50 C for 60 minutes with a max. environmental temperature of 50 C 5 also for P abs bar Electrical protection Short circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration according to DIN EN 60068 6 Shock according to DIN EN 60068 7 Filling fluids Options Materials G /": 0 g RMS (5... 000 Hz)others except G /": 0 g RMS (5 000 Hz) G /": 500 g / msec others except G / : 00 g / msec silicon oil food compatible oil with FDA approval (Mobil DTE FM ; Category Code: H; NSF Registration No.: 066) Pressure port stainless steel.4404 (6 L) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated Seals (media wetted) standard: FKM (recommended for medium temperatures 00 C) option: FFKM (recommended for medium temperatures > 00 C) clamp and dairy pipe: without Diaphragm Media wetted parts stainless steel.445 (6 L) / Tantalum and Hastelloy C 76 (.489) on request pressure port, seals, diaphragm DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de

DMP P Explosion protection (only for 4 0 ma / wire) Approval DX 9 DMP P IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga (zone 0: II D Ex ta IIIC T 85 C, IP6x, in preparation) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh Max. temperatures for in zone 0: 0... 60 C with p atm 0.8 bar up to. bar environment in zone or higher: 0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 5 ma Weight min. 00 g (depending on process connection) Installation position any (standard calibration in a vertical position with the pressure port connection down; differing installation position for P N bar have to be specified in the order) Operational life > 00 x 0 6 pressure cycles CE conformity EMC Directive: 004/08/EC Wiring diagrams wire system (current) p supply + wire system (current / voltage) supply + p V S I supply V S I/U supply signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (only wire) Electrical connections (dimensions in mm) Binder 7 (5 pin) 4 Mx / metal (4 pin) Shield ground pin 5 4 field housing IN + IN OUT+ cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 Mx 4 pin cable outlet with PVC cable (IP 65) IP 67) (IP 67) (IP 67) 6 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 7 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 6 standard: m PVC cable without ventilation tube (permissible temperature: 5 70 C) 7 different cable types and lengths available, permissible temperature depends on kind of cable DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de

DMP P Mechanical connection (dimension in mm) Option G/" flush with ISO 4400 8 G/4" flush G" flush G/" flush G" flush with ISO 4400 with ISO 4400 with radial o ring with radial o ring G" cone dairy pipe (DIN 85) clamp (ISO 85) cooling element 00 C with ISO 4400 with ISO 4400 with ISO 4400 SIL and SIL Ex version: total length increases by 6.5 mm! metric threads and other versions on request 8 possible only for P N bar dimension in mm size DN 5 DN 40 DN 50 A 45 B 44 56 68.5 dimension in mm size DN 5 DN 8 DN 5 A 45 B 50.5 50.5 64 This This data datasheet contains product specification, properties are are not not guaranteed. Subject to to change without notice. DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de

DMP P DRUCK & TEMPERATUR LEITENBERGER GMBH Spezifikationsblatt / specification sheet DMP P - - - - - - - - - Messgröße Eingang Ausgang relativ absolut 5 0 0 5 0 [bar] 0,0 0 0 0 0,6 6 0 0 0,5 5 0 0 0,40 4 0 0 0 0,60 6 0 0 0,0 0 0,6 6 0,5 5 0 4,0 4 0 0 6,0 6 0 0 0 0 0 6 6 0 5 5 0 40 4 0 0-0 X 0 Sondermessbereiche 9 9 9 4 0 ma / -Leiter 0 0 ma / -Leiter E S 0 0 V / -Leiter Ex-Schutz 4 0 ma / -Leiter SIL 4 0 ma / -Leiter SIL mit Ex-Schutz 4 0 ma / -Leiter ES Genauigkeit für P N 0,4 bar 0,5 % für P N < 0,4 bar 0,5 % 5 Option für P N 0,4 bar 0,5 % Elektrischer Anschluss Stecker und Kabeldose ISO 4400 Stecker Binder Serie 7 (5-polig) Kabelausgang mit PVC-Kabel 0 0 0 0 T A 0 Kabelausgang T R 0 Stecker Mx (4-polig) / Metall M 0 Kompakt-Feldgehäuse Edelstahl.405 8 5 0 9 9 Mechanischer Anschluss G/" mit frontbündig geschweißter Membrane (DIN 85) 4 Z 0 0 G/4" mit frontbündig geschweißter Membrane (DIN 85) Z 0 G" mit frontbündig geschweißter Membrane (DIN 85) Z G" DIN 85 mit rad. O-Ring und frontbündiger Membrane Z 5 7 G/" DIN 85 mit rad. O-Ring und frontbündiger Membrane Z 6 G " Konus K Clamp DN 5 (ISO 85) C 6 Clamp DN 8 (ISO 85) C 6 Clamp DN 5 (ISO 85) C 6 Milchrohr DN 5 (DIN 85) M 7 Milchrohr DN 40 (DIN 85) M 7 5 Milchrohr DN 50 (DIN 85) M 7 6 9 9 Trennmembrane Edelstahl.445 (6L) Tantal T auf Anfrage Hastelloy C-76 (.489) H Dichtung für Clamp oder Milchrohr: keine 0 für Zollgewinde - : FKM für Zollgewinde - Option: FFKM 7 Füllflüssigkeit Silikonöl Lebensmitteltaugliches Öl Sonderausführungen mit Temperaturentkoppler bis 00 C : m PVC-Kabel ohne Belüftungsschlauch (Temperatureinsatzbereich: -5 70 C), auf Anfrage Kabel mit Luftschlauch (Code TR0 = PVC-Kabel), Kabel in verschiedenen Ausführungen und Längen lieferbar, Temperatureinsatzbereich abhängig vom Kabel; Kabel nicht im Preis enthalten 0 0 0 0 0 9 9 Die Nutüberwurfmutter muss bei elektrischen Anschluss Feldgehäuse in Kombination mit mechanischen Anschluss Milchrohr bei der Herstellung auf dem Druckmessumformer montiert werden. Die Nutüberwurfmutter muss als separate Position bestellt werden. 4 möglich nur für P N bar DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D 78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7 9090 0 Fax +49 (0) 7 9090 99 E Mail: DT Info@Leitenberger.de www.druck temperatur.de t entnommen werden. Technische Änderungen vorbehalten. eser Preisliste enthalten die Spezifikation der Produkte, nicht die Zusicherung von Eigenschaften. Ausführliche Informationen zu den Bestelloptionen können dem Datenblatt e Die Angaben dies