Magnetic inductive flow sensors
|
|
- Lisa Beutel
- vor 6 Jahren
- Abrufe
Transkript
1 Magnetic inductive flow sensors Series induq VMM Advantages Rapid signal processing with a 6-bit microcontroller Password protection Self-test anguage selection: German, English ow-flow suppression Empty pipe detection Easy menu-driven operation and programming (e.g. measuring range, pulse rate) by the user by means of a two-line alphanumeric display Delivery inlcuding works calibration certificate Outputs Analog output (0)4...0 ma Frequency or Impulse output alarm / status outputs Displays Flow rate, several total flows Flow velocity Relative flow rate [%] Mass and mass flow (enter density) Units Divers, e.g. USG/min, m³/h, l/s,, kg/h (density programmed) Compact type Separate type
2 Type VMM5 VMM5 VMM3 VMM40 VMM50 VMM65 VMM80 VMM00 VMM5 VMM50 VMM00 Characteristics Nominal pipe size ½ ¼ ½ ½ Process connection Flange connection in accordance with ANSI 6.5, EN 09- or JIS 0 0K Flow range Flow velocity [ft/s] Flow velocity [m/s] Volumetric flow [GPM] Accuracy* v = ft/s v < 3.8 ft/s additionally Frequency output Analog output Repeatability Response time Signal output starting from Medium / min. conductivity of medium Medium temperature Hard rubber PTFE Ambient temperature Hard rubber PTFE Display Storage and transport temperature Pressure rating ANSI RF ±0.5 % of reading ±0.4 % of reading ± ft/s ±0.05 % per 0 K ±0. % per 0 K ±0.5 % of reading < 00 ms** > 0 ft/s Water and other conductive liquids / 50 µs/cm F F at 580 psi F at 36 psi F at 3 psi Min. 4 F (steel) Min. -4 F (stainless steel) F F Min. 4 F (steel) Min. -4 F (stainless steel) F*** F 85 psi (Process connection, steel) 30 psi (Process connection, stainless steel) EN09- **** PN 0 PN 5 JIS 0 0K Display Operation Degree of protection EN psi CD two-line, backlight 6 keys, menu-driven IP67 * Reference conditions: Media temperature F; Ambient temperature F; warm-up period 30 min.; straight pipe lengths; inlet 5 x inner diameter, outlet x inner diameter, regularly centered and earthed ** Depending on the electronics settings *** The readability of the CD display is restricted below 3 F **** 8 bolt flanges
3 Output signals Type VMM5 VMM5 VMM3 VMM40 VMM50 VMM65 VMM80 VMM00 VMM5 VMM50 VMM00 Puls / frequency output Configuration Pulse signal or frequency signal selectable Pulse output Pulse rate (factory-set) [pulses / gallon] Pulses/Time 000 pulses/s Pulse width 0. ms (max. s), adjustable Signal shape Squarewave signal Frequency output Factory-scaled measuring range corresponds to 0... khz [GPM] Frequency 0... khz Signal shape Squarewave signal Analog output Factory-scaled measuring range corresponds to ma [GPM] Operating range ma / ma, selectable Current limitation.6 ma Max. burden 600 Ω Short-circuit proof Permanent Alarm output Quantity Version Optocoupler Function Status output: Preflow, backflow, MIN flow rate, MAX flow rate, alarm (adjustable) Switching values U max : 30 V; I max : 60 ma; P max :,8 W Electrical data Electrical connection Cable gland M0 x.5 Power supply 5 VAC (-5 % / +0 %), 50/60 Hz 30 VAC (-5 % / +0 %), 50/60 Hz VDC Current consumption 5 VA 3
4 Separate type (Display) induq induq ±80 rotatable Wall bracket Wall bracket 5.87 Wall bracket (Verwendungsbereich) (Zul. Abw.) Datum Name earb Thomas Gepr Thomas Norm Dr. Siebert & Kühn GmbH & Co KG Struthweg Kaufungen Zust Änderung Datum Name (Urspr.:) (Oberfläche) Katalog USA ISO 768-m DIN ISO 30 Maßstab: : (Werkstoff, Halbzeug) (SIKA-Artikelnummer) (Ers. f.:) VMM... (Gewicht) Magnetisch-Induktiver Durchflusssensor Type VMM3-80 latt MID-04 4 l. (Ers. d.:) Separate type (Sensor) ( : ) 4.9 ( : ) 4.9 H.7.0 H.7.0 nd (Verwendungsbereich) (Zul. Abw.) Datum Name earb Thomas Gepr Thomas Norm Dr. Siebert & Kühn GmbH & Co KG Struthweg Kaufungen Zust Änderung Datum Name (Urspr.:) (Oberfläche) Katalog USA ISO 768-m DIN ISO 30 nd Maßstab: : (Werkstoff, Halbzeug) (Gewicht) (Verwendungsbereich) (Zul. Abw.) (Oberfläche) (SIKA-Artikelnummer) VMM... Katalog USA ISO 768-m DIN ISO 30 Magnetisch-Induktiver Durchflusssensor Type Datum Name VMM3-80 earb Thomas Gepr. latt Thomas MID-04 Norm 4 l. (Ers. f.:) (Ers. d.:) Dr. Siebert & Kühn GmbH & Co KG Struthweg Kaufungen Zust Änderung Datum Name (Urspr.:) Maßstab: : (Werkstoff, Halbzeug) (SIKA-Artikelnummer) (Ers. f.:) VMM... (Gewicht) Magnetisch-Induktiver Durchflusssensor Type VMM3-80 latt MID-04 4 l. (Ers. d.:) 4
5 Compact type ( : ) induq induq ±80 rotatable H H Dimensions [in] Process connection Installation length Weight ANSI RF [lb] ANSI 6.5 EN 09- JIS 0 0K Hard rubber PTFE Tolerance D H Sensor Compact Without protection rings With protection rings type ½ DN / DN / ¼ DN / ½ DN / DN / ½ DN / DN / DN / DN / DN / DN / Materials Not in contact with fluid Display housing Casted aluminum Sensor housing Steel Measuring pipe Stainless steel Process connection Steel.0460 or stainless steel.4404 In contact with fluid Electrodes Stainless steel.457 or Hastelloy C76 Measuring pipe lining PTFE or Hard rubber 5
6 Order code Example VMM3 A 0 0 KAMA 0 Nominal pipe size ½ ¼ ½ ½ Process connection ANSI RF EN 09- PN 0 starting from 4 / DN 00 EN 09- starting from ½ / DN 65 EN 09- PN 5 starting from 4 / DN 00 EN 09- starting from ½ / DN 5 JIS 0 0K Material process connection Steel.0460 Stainless steel.457 ining PTFE Hard rubber Material electrodes Stainless steel.457 Hastelloy C76 Earth electrode Without One Two Type Compact type with display Separate type with display Power supply 5 VAC, 50/60 Hz 30 VAC, 50/60 Hz VDC VMM5 VMM5 VMM3 VMM40 VMM50 VMM65 VMM80 VMMC VMMV3 VMM3 VMMC I A C D J 0 0 KAMA GAMA 4 3 6
7 Earthing ring VMM Protection rings VMM Earthing ring An earthing ring is used for the electrical reference and earthing of the medium being measured. It is necessary if the pipes are not electrically conductive or lined (plastic or concrete pipes, etc.). The earthing ring must be connected to the provided earthing screw of the sensor. Retrofitting is possible. The earthing rings are made of stainless steel.457. Pair of protection rings Protection rings protect the inlet and outlet edges of the sensor against mechanical damage, in particular when abrasive media such as gravel, sand, etc. are concerned. At the same time, they also serve as earthing rings. The protection rings are firmly screwed to the sensor and are made of stainless steel.457. Sensor cable set Sensor cable between sensor and display unit (separate design) consisting of magnetic power cable and electrode cable for configuration of M6 x.5 screw connection. 7
Vortex flow sensors. Series VVX. Type VVX20. Type VVX15
Vortex flow sensors Series VVX Type VVX5 Type VVX0 Technical data VVX5 VVX0 VVX5 Nominal pipe size ½ ¾ Process connection ½ NPT ¾ NPT or QuickFasten NPT Inner diameter 0.5 inch 0.75 inch inch Flow range
MehrDatenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs
2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with
MehrWestenberg Wind Tunnels
MiniAir20 Hand measurement device for flow, humidity and temperature The hand measurement device MiniAir20 is used for the acquisition of temperature, relative humidity, revolution and flow velocity such
MehrNewest Generation of the BS2 Corrosion/Warning and Measurement System
Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing
MehrThread connections QuickFasten. vortex Flow sensors
JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors_USA 07/07 53 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated
MehrABB i-bus EIB. EIB Power Supply Units
ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
Mehrdiameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
MehrCompressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3
3/2 Wegeventil mit PIEZO-Pilotventil Baureihe P20 3/2 way valve with Piezo-pilot valve Series P20 P20 381RF-* NW 2 Eigenerwärmungsfrei Ein Produkt für alle Ex-Bereiche Kompatibel zu Microcontrollern Kompatibel
MehrDatenblatt Flüssigkeitsringpumpe Data sheet liquidring pump
Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Serie Series L-BV2 L_200 Flüssigkeitsringpumpen Liquid ring pumps 3 AC; 50/60 Hz 3 AC; 50/60 Hz Vakuumbetrieb Vacuum operation Typen Types 2BV2
MehrThe future of snow. The silent hero of snow guns
The future of snow The silent hero of snow guns EN 4 Maximum snow production. Minimum noise level. High energy efficiency. Performance was never so quiet. All the appreciated features of TITAN with a
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff
Mehrdiameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrOverview thermostat/ temperature controller
Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:
MehrOvercurrent Protection Leaded Disks, Coated, 12 V, 24 V
B99* C 93 C 99 Applications Overcurrent and short-circuit protection b 3, max. Features Lead-free terminals Manufacturer s logo and type designation stamped on in white Low resistance For rated currents
MehrStahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting
Stahlgitterwiderstandselemente Steel Grid Resistor lements 500 W für inbau 500 W for fitting Stahlgitterwiderstandselemente RSW RSW 54 500 W für inbau Steel Grid Resistor lements RSW to RSW 54 500 W for
Mehr3. Technical data 3. Technische Daten
661 078 3. Technical data 3. Technische Daten Design / Bauart Pressure switch, vacuum switch and differential pressure switch / Druckwellenschalter, Vakuumschalter und Differenzdruckschalter Function
MehrDGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES
DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES Ecksicherheitsventile aus Rotguss mit Nirofeder Typ 606 GF/GFL/tGF für neutrale Flüssigkeiten,Dampf und gasförmige Medien Safety valves made of red brass
MehrProgrammierbares Multisystem Serie PMS XPULSE
Serie PMS XPULSE Series PMS XPULSE Mechanische Daten / Mechanics Data Haube / Cover: Aluminium / Aluminium Flansch / Body: Aluminium / Aluminium Welle / Shaft: Edelstahl / Stainless steel Kugellager /
MehrRohrschieber mit Schließfeder Slide Valve spring loaded
Rohrschieber mit Schließfeder Slide Valve spring loaded Rohrschieber als automatisches Entlüftungsventil Slide Valve as automatic air relief valve Type: RSF DN: 50 300 (2 12 ) PN: 16 160 (Class 150 900)
Mehr2/2-way solenoid valve - Type 218
- direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN
MehrTECHNICAL DATA SHEET Member of Uponor Group
TECHNICAL DATA SHEET Member of Uponor Group Fresh water unit FWS-V HE FWS-V-6 HE-3 FWS-V-8 HE-3 Equipment example with process water circulation B E A C D Hydraulic diagram D C E A B A B C D E Drinking
MehrLufft UMB Sensor Overview
Lufft Sensor Overview Wind Radiance (solar radiation) Titan Ventus WS310 Platinum WS301/303 Gold V200A WS300 WS400 WS304 Professional WS200 WS401 WS302 Radiance (solar radiation) Radiation 2 Channel EPANDER
MehrDistance sensor. Sn = 0,2 6 m
Sn = 0,2 6 m + Analogausgang + analogue output, Sn = 0,2 6 m für Reflektor mit Analogausgang for use with reflector with analogue output Sn = 0,2 30 m Schaltabstand Operating distance Funktion Operating
MehrCertificate of conformity Generating unit, NS-protection
Certificate of conformity Generating unit, NS-protection Applicant: Product: Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with
MehrERHARD is a company of. Datasheet ERHARD ECR check valve
ERHARD is a company of Datasheet The compact check valve for clamping The is clamped between two flanges as a reflux preventer. It has two vanes which, for example, open on starting a pump and will iediately
Mehr2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich
Mehr0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50
MehrAttenuator and Distribution System Zehnder ComfoWell 220
Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for
Mehr/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.
EZ-0225-V10 Air Bearing Spindle High accurancy air bearing spindle with direct drive. Equipped with an water-cooled synchronous motor (frequency at nominal speed 400 Hz), Power output 1880 W. Rotary encoder
MehrInkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung
Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe
Mehrservogesteuert pilot operated
1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung
MehrTelefon: +49 (0) 5251 / Telefax: +49 (0) 5251 /
1 / 9 Assembly: Assembly plate: The left and right assembly plates are screwed onto the side of the vehicle frame via the designated bore holes. The following items shall be used per side for this purpose:
MehrBaureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator
Bauart Nennweite DN 8 DN 50 Anschluss Kugelhahn mit pneumatischem Schwenkantrieb G1/4 G2 Betriebsdruck Messing: DN15 DN20 = PN30 DN25 = PN16 DN32 DN50 = PN10 Edelstahl: PN63 Gehäusewerkstoff Armatur: Edelstahl
MehrSignal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen
LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL Sender/Empfänger mit Outdoor-Box Merkmale LWL-SBR, Übertragungsweiten bis zu 1500 m Wandlung üblicher Rechtecksignale
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung
MehrLORENZ MESSTECHNIK GmbH
DR-2112, DR-2112-R DR-2412, DR-2412-R Drehmomentsensor, rotierend Torque Sensor, rotating Drehmomentsensor, rotierend Torque Sensor, rotating Nenndrehmoment von 0,1 N m... 20000 N m - Nominal torque from
MehrInductive proximity switch
3RG4070-0CD00-PF NO and NC / Schließer und Öffner 3RG4070-3CD00-PF NO and NC / Schließer und Offner 3RG4070-7CD0-PF NO and NC Schließer und Öffner 3RG4070-7CD0-PF NO and NC Schließer und Öffner Cable /
MehrZehnder ComfoWell 220
Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft
direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direct acting with isolating diaphragm fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite
MehrTypenreihe GH Lifting Solenoids
Hubmagnete Lifting Solenoids Bauart Hubmagnete der Reihe GH können mit Durchmessern zwischen 5 mm und 65 mm und mit Hublängen von 8 bis 60 mm gefertigt werden. Serien mäßig wer den sie mit Wellenenden
MehrIDG. Drehzahlsensor / Speed Sensor
Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor
MehrZehnder ComfoWell 320
Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with locking slides for
Mehr~XECRO. sensing ahead NPN PNP 1/+ 1/+ NPN 4/S 4/S PNP. Data sheets are available on
~XECRO sensing ahead Benefits: Pressure proof up to 1000 bar (14503 psi) Stainless steel housing (SS304) Sensing face made of stainless steel or ceramic Optional LED switching indicator simplifies the
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135
zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff
MehrTechnische Daten /Techn. Terms Bedingungen/Conditions Wert/Value
High output siren Technische Daten /Techn. Terms Bedingungen/Conditions Wert/Value Betriebsspannungsbereich Operating Voltage V (DC) 10-30 Stromaufnahme Current Consumption max. ma 260 Schalldruckpegel
MehrInduktive Näherungsschalter inductive proximity switches
Zylindrisch DC cylindric DC Zylindrisch DC Vollmetall cylindric DC full metal Hochtemperatur high temperature Schweißfest weld resistant Druckfest pressure resistant Analog analog Namur namur AC AC Kunststoff
MehrCABLE TESTER. Manual DN-14003
CABLE TESTER Manual DN-14003 Note: Please read and learn safety instructions before use or maintain the equipment This cable tester can t test any electrified product. 9V reduplicated battery is used in
Mehrdirektgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow
1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
MehrTechnisches Datenblatt Technical Data Sheet. Anzeige-, Überwachungs- und Regelgerät. Schalttafel-Einbaugerät für 24 VDC
SEG 1060 Anzeige-, Überwachungs- und Regelgerät Schalttafel-Einbaugerät für 24 VDC Signal 0/4... 20 ma, 0 10 V, Frequenz Sensorstromversorgung galvanisch getrennt Instrument for indicating, monitoring
MehrElectrical testing of Bosch common rail solenoid valve (MV) injectors
Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445
MehrLORENZ MESSTECHNIK GmbH
DMS- Messverstärker - SG Measuring Amplifier / 2S Zum Anschluss von bis zu 4 350 Ω- Wägezellen 4- oder 6- Leitertechnik ±10 Vdc oder 0-10 Vdc und 4-20 ma Analogausgang Kontrollsignal für die Kalibrierung
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
MehrWAM 235 Analysemessgerät mit Loggerfunktion WAM 235 Analysis instrument with logger function
WAM 235 Analysemessgerät mit Loggerfunktion WAM 235 Analysis instrument with logger function WAM 235 Einsatzprofil Das ideale Handmessgerät zur Messung von ph, Salzgehalt, ORP, CD, TDS, DO und Temperatur
MehrInduktive Ringsensoren inductive ring sensors
arbeiten als Durchlasssensor. Der aktive Bereich befi ndet sich innerhalb des Ringes. Dabei werden alle Teile aus Metall, auch unmagnetische Leicht- und Buntmetalle sowie ferromagnetische Teile erfasst.
MehrAC/DC-Schaltnetzteile 100 W AC/DC Switching Power Supplies 100 W. Merkmale / Features. Eingangsbereich 90...264 V AC
E176177 Merkmale / Features Eingangsbereich 90...264 V AC / Universal Input 90...264 V AC Wirkungsgrad bis zu 90 % / Efficiency up to 90 % Full-Brick Gehäuse / Full Brick Package Aktiv PFC Funktion / Active
MehrTECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor
TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,
MehrGK-Serie MONOVOLT. DC/DC-Wandler
GK-Serie: MONOVOLT DC/DC-Wandler 30 bis 120 Watt primärgetaktete DC/DC-Einschubwandler mit einer in 3HE-Eurokassetten für den Einsatz in 19"-Baugruppenträgern nach DIN41494 Kompakter Aufbau in stabiler
MehrEx solenoid interlocks // Ex AZM 415
Features/Options Ex zone 1 and 21 Special version up to +90 C ambient temperature for dust Ex zone 21 available (HU) Two Ex switch inserts in one enclosure Spring-to-lock or power-to-lock principle Problem-free
MehrZehnder CLD. Housing for walls, floors and ceilings
Benefits Suitable for wall, floor or ceiling installation Air volumes up to a maximum of 30 m 2 /h (ComfoTube 75) and 45 m 2 /h (ComfoTube 90) Can be installed in timber or solid constructions Extract
MehrTechnical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00)
Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00) Inhalt S./P. 1. Beschreibung /
MehrUltraschallsensoren ultrasonic sensors
Zylindrisch cylindric Rechteckig cuboid erfassen mithilfe von Schallwellen berührungslos und verschleißfrei eine nahezu alle Objekte. Dabei spielt es keine Rolle, ob das Objekt durchsichtig, metallisch,
MehrMade in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]
NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,
MehrAttenuator and Distribution System Zehnder ComfoWell 320
Attenuator and Distribution System Zehnder ComfoWell 32 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy
MehrP-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series
3/2-way, G 1/4, Technical data for series -310-311 -312-320 -320-Q -322-322-Q Design and function Pneumatically operated spool valve. The valve switches upon pressurization of the pilot port (10 or 12).
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich
Mehr+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W
Kraftvoll bis 200 W + Powerful up to 200 W + + Kleine Bauform Small size Betriebsanzeige über LED und Meldekontakt Status LED and signal contact Zuverlässig entkeimen. Reliable desinfection. Linear V UV
MehrBaureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich
MehrA P max. 16bar P R max. 64bar R P max. 16bar
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich
MehrZellstoffpuffer Anschlagpuffer. Cellular Plastic Buffers Impact Buffers. Technische Daten / Zeichnung technical data / drawing
Quality. Safety. Efficiency. Only Quality is economical in the long run German specialist in brake + safety technology. Zellstoffpuffer Anschlagpuffer Cellular Plastic Buffers Impact Buffers Technische
MehrD4E - Analog Meters for alternating current 4 module
ANALOGANZEIGER ANALOG METERS Analoganzeiger - D4E für Wechselstrom 4 Modul D4E - Analog Meters for alternating current 4 module D4E Direkte Anzeige des Eingangstroms oder des Nennstroms von externen Stromwandlern
MehrWalter Buchmayr Ges.m.b.H.
Seite 1/10 Chapter Description Page 1 Advantages 3 2 Performance description 4 3 Settings 5 4 Options 6 5 Technical data 7 6 Pictures 8 http://members.aon.at/buchmayrgmbh e-mail: walter.buchmayr.gmbh@aon.at
Mehr2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich
MehrMaterialdruckregler Material pressure regulator
Rev. 3.11 Zubehör / Accessories Seite / page 29 97974x / 97956x / 97958x Der Materialdruckminderer dient zum Herabsetzen und Ausgleichen von Materialdrücken. Er dämpft Druckschwankungen bei Förderpumpen
MehrSnap-in Outline Drawings / Snap-in Bauformen
Snap-in Outline Drawings / Snap-in Bauformen C (D = 20 ~ 35mm, short pin T = 4.0 ± 0.5mm) R (D = 20 ~ 35mm, long pin T = 6.3 ± 1.0mm) S (D = 35 ~ 40mm, standard T = 6.3 ± 1.0mm) X (D = 35 ~ 40mm, short
MehrManometerabsperrventile MAV16270; MAV16271; MAV16272 Manometer gauge valves MAV16270; MAV16271; MAV Spindel Edelstahl stem stainless steel
Manometer gage valves MAV16270; MAV16271; MAV16272 MAV16270 Form A Abbildng ggf. abweichend pictre may be different Material material Gehäse Messing body brass Spindel Edelstahl stem stainless steel Überwrfmtter
MehrDatenblatt / Data sheet
Seite/Page 1/5 Abbildungen / Illustration Maßzeichnung / Dimensions Produktbeschreibung Product specification Kompaktes, steckbares Relais für den industriellen Einsatz. Compact, pluggable relay for industrial
MehrSICHERHEITSVENTILE OHNE BAUTEILPRÜFUNG SAFETY VALVES WITHOUT TEST CERTIFICATE. Type 602 E / Type 601 T for liquids, gaseous media and steam
Ecksicherheitsventile aus Rotguss Angular safety valves made of red brass Typ 602 E / Typ 601 T für Flüssigkeiten, gasförmige Medien und Dampf Type 602 E / Type 601 T for liquids, gaseous media and steam
MehrPosition switch // ES 411 / EM 411
Features/Options Metal enclosure ES 411: Slow action A, change-over contact, change-over contact with overlapping or 2 NC contacts with double break EM 411: Snap action, change-over contact with double
MehrProduktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.
Produktdatenblatt Artikel Nr.: 341107 Wandaufbauleuchte, Alpha II, Weiß, 220-240V AC/50-60Hz, 100,00 W Technische Daten Charakteristik Material Farbe Weiß Optik im Lieferumfang Elektrische Daten Leistung
MehrAnalog GSM-Gateway TRF
Analog GSM-Gateway TRF GSM gateway for voice- or fax transmission 1 2009 com.sat GmbH Kommunikationssysteme Schwetzinger Str. 19 D-68519 Viernheim www.comsat.de Tel: +49-(0)180-3-768837 The connecting
MehrPSA SEGURO Flexikeil-Absperrschieber PSA SEGURO Flexible Wedge Gate Valve
PSA SEGURO Flexikeil-Absperrschieber PSA SEGURO Flexible Wedge Gate Valve Typ (Type) GSAL DN 40 500 PN 10 250 mit Flanschen oder Anschweißenden DN 40 500 PN 10 250 with flanges or welding ends - Ausführung
MehrInductive proximity switch
RG44-6AD00-PF RG44-6AD04-PF RG44-AD00-PF Size / Bauform Mounting / Einbau screw terminals (terminal compartment) Schraubklemmen (Anschlußraum) screw terminals (terminal compartment) Schraubklemmen (Anschlußraum)
Mehr2/2-way plastic solenoid valve - Type 104
- direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 1,0 2,5 Druckbereich Gehäusewerkstoff
MehrHEAG 151, 152, 153, 154 Digital Converter
Montage- und Betriebsanleitung Installation and operating instructions MB095-11055704 Baumer_HEAG151-152-153-154_II_DE-EN (16A1) HEAG 151, 152, 153, 154 Digital Converter 1-2 Allgemeine Hinweise - Funktionsweise
Mehr~XECRO. sensing ahead NPN PNP 1/+ 1/+ NPN 4/S 4/S PNP. Data sheets are available on
~XECRO sensing ahead Benefits: Fully embedded amplifier Very short housings also in the Advanced Sensing Range Class Stainless steel housings, potted with epoxy and fiber-glass reinforced substrates or
MehrELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary
Mehr3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled
fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50
MehrDC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC
AC-RIDER 80VA WWW.AC-RIDER.COM TÜV Rheinland geprüfte Sicherheit Besondere Merkmale Features 12 VDC Eingang 12 VDC input Hoher Wirkungsgrad High efficiency Überlast / Kurzschlußfest Overload / Short-circuit
MehrAttenuator and Distribution System Zehnder ComfoWell 520
Attenuator and Distribution System Zehnder ComfoWell 520 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy
MehrElectrical testing of Bosch common rail piezo injectors
Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid
MehrP A max. 100bar A P max. 16bar
1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design
MehrWith pipe tees (inline) Direct installation (insertion) With interchangeable paddles For air flow. flow switches
JJ With pipe tees (inline) JJ Direct installation (insertion) JJ For HVAC applications JJ With interchangeable paddles JJ For air flow flow switches DS_Flow_switches 06/2017 7 Flow switches SIKA has over
MehrUmschaltventile Magnete
Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC
Mehr