HBC Ex-Systeme (ATEX) Gerätekategorie (Zone) M2 2G (Zone 1) 3G (Zone 2) 2D (Zone 21) 3D (Zone 22) Gruppe IIB IIC IIB IIC I M2 Ex ia I Mb II 2G Ex ia IIB T4 Gb II 2G Ex ia IIB T4 Gb II 2D Ex ia IIIC T100 C Db II 2D Ex ia IIIC T100 C Db Z-G00117 Z-G00117 Z-G00117 Z-G00117 Z-G00117 micron 4 II 3G Ex ic IIC T5 Gc Z-G00134 I M2 Ex ib I Mb II 2G Ex ib IIB T4 Gb II 2G Ex ib IIB T4 Gb II 2D Ex ib IIIC T100 C Db II 2D Ex ib IIIC T100 C Db Z-G00135 Z-G00135 Z-G00135 Z-G00135 Z-G00135 I M2 Ex ib I Mb II 2G Ex ib IIB T4 Gb II 2G Ex ib IIB T4 Gb II 2D Ex ib IIIC T100 C Db II 2D Ex ib IIIC T100 C Db Z-G00131 Z-G00131 Z-G00131 Z-G00131 Z-G00131 spectrum 1 / 3 mit LCD II 3G Ex nl IIB T4 Z-G00129 spectrum EEX optional mit LCD / 3 I M2 Ex ib I II 2G Ex ib IIB T4 II 2G Ex ib IIB T4 II 2D Ex tda21 IP65 T80 C II 2D Ex tda21 IP65 T80 C Z-G00032 Z-G00106 Z-G00106 Z-G00107 Z-G00107
HBC Ex-Systeme (ATEX) Gerätekategorie (Zone) M2 2G (Zone 1) 3G (Zone 2) 2D (Zone 21) 3D (Zone 22) Gruppe IIB IIC IIB IIC HBC-Empfänger FSE 516 II 3D Ex tc IIIC T80 C X Dc Z-G00133 Z-G00133 FSE 524 II 3G Ex na nc IIC T4 X Z-G00136 Z-G00136 Z-G00138 Z-G00138 Z-G00139 Z-G00139
HBC Ex-Systeme (IECEx) Geräteschutzniveau (Zone) Mb Gb (Zone 1) Gc (Zone 2) Db (Zone 21) Dc (Zone 22) Gruppe IIB IIC IIB Ex ib I Mb Ex ib IIB T4 Gb Ex ib IIB T4 Gb Ex ibd21 T100 C Db IP6X Ex ibd21 T100 C Db IP6X Z-G00135 Z-G00135 Z-G00135 Z-G00135 Z-G00135 Ex ib I Mb Ex ib IIB T4 Gb Ex ib IIB T4 Gb Ex ib IIIC T100 C Db Ex ib IIIC T100 C Db Z-G00131 Z-G00131 Z-G00131 Z-G00131 Z-G00131 spectrum EEX oder Ex ib I Mb Ex ib IIB T4 Gb Ex ib IIB T4 Gb Ex ibd21 T100 C Db IP6X Ex ibd21 T100 C Db IP6X Z-G00126 Z-G00114 Z-G00114 Z-G00114 Z-G00114 HBC-Empfänger
HBC Ex-Systeme (NEC) NEC 500 Class Class I Division Division 1 Division 2 Z-G00130 Z-G00130 Z-G00132 Z-G00132 NEC 505 Class Class I Division Zone 0 Zone 1 Zone 2 Class I, Zone 0, AEx ia IIB T4 Class I, Zone 0, AEx ia IIB T4 Class I, Zone 0, AEx ia IIB T4 Z-G00130 Z-G00130 Z-G00130 Class I, Zone 0, AEx ia IIB T4 Class I, Zone 0, AEx ia IIB T4 Class I, Zone 0, AEx ia IIB T4 Z-G00132 Z-G00132 Z-G00132
Zubehör für HBC Ex-Systeme Akkus und Ladegeräte Druckfeste Kapselung Sender Akku Ladegerät Kennzeichnung Empfänger micron 4 BE223001 BF223000 QA108600 QD108300 BE223000 BE223000 BE223001 spectrum 1 BA2250 QA109600 QD109300 II 2G Ex d IIB T6 II 2D Ex td A21 IP6x T80 C BA2250 QA109600 QD109300 (auch mit LCD) (auch mit LCD) BA214061 BA213020 BA214061 BA213020 QA115600 QD115300 QA115600 QD115300 Antennen (ATEX) Typ Modulcode Frequenz Kategorie (Zone) A-A00057 A-A00058 AA050016 AA050017 2G (Zone 1) 2D (Zone 21) spectrum EEX (ATEX) oder BE225000 FuB06EEX (BE206000) QE109600 QE109300 QE115600 QE115300 AA050014 A-A00055 AA050015 A-A00056 3G (Zone 2) 3D (Zone 22) spectrum EEX (IECEx) oder BE208001 QE115600 QE115300 Antennen (IECEx) Typ Modulcode Frequenz EPL (Equipment Protection Level) AA050018 A-A00059 AA050019 A-A00060 Gb Db