ISA-PLAN - Precision Resistor Type PBV



Ähnliche Dokumente
FMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) , info@rosenberger.de,

Taster gerade - Einlöt / SMT / Kappen Straight Tact Switches - Solder-in / SMT / Caps

336 Wannenstiftleisten RM 1,27mm, gerade/gewinkelt Box Headers, 1.27mm Pitch, Straight/Right-Angled

Schalten einer kapazitiven Last mit einem Transistor

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung

fastpim 1 H fast switching H bridge module Features: - 1 Phase Input Rectifier Bridge - 1 Phase fast switching IGBT + FRED full H bridge - NTC

SFH 900. Miniatur-Reflexlichtschranken Miniature Light Reflection Switches SFH 900

Micro-RF. 294 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) ,

Kuhnke Technical Data. Contact Details

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V

SPINNER MOBILE COMMUNICATION

Certificate of conformity Generating unit, NS-protection

г.минск тел.8(017) DD 400 S 17 K6 B2 RMS, f = 50 Hz, t = 1 min. V ISOL 4 kv

SIMID Size 1210 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 100 µh Rated current 65 to 800 ma

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Overview thermostat/ temperature controller

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen

Datasheet. Page 1 of 7

Standard Power Integrated Module

AGM-Batterie Model: WT-SA12-12 (12V 12AH)

Datenblatt. P-series PDU 2.5/4/4AN

Sixpack with NTC. Features / Eigenschaften. power range up to 1,2 kv / 25 A (trench) 3 Phase IGBT FRED Inverter Bridge 6-Pack flow concept NTC

Certificate of conformity Generating unit, NS-protection

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

Asynchronous Generators

Ein- und Ausgangsspannung V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

Datenblatt / Data sheet

Gesamtübersicht Ringkerndrosseln. summary toroidal-chokes. Tauscher Transformatoren

Stahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting

Datenblatt / Data sheet

Umschaltventile Magnete

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx.

Technische Daten / Technisches Merkblatt (nach pren ) ECHOGRAPH 1016B (Best.-Nr )

Snap-in switch for switches PSE, MSM and MCS 30

Umschaltventile Magnet

SMD Varistors Monolithic; Standard Series

Pneu. Linearantriebe mit externer Gleitführung Baureihe PLS

- Characteristic sensitive Small temperature differences. - Low Sensitivity 42,8 µv/k for Cu-Constantan

SMT Chipinduktivitäten SMT Chip Inductors. Baugröße / Size 0603 (1608) Serie / Series compliant

Jan 2014 Rev C

Taster LDT, Schalter LDS Switches in momentary action LDT, and latching action LDS

Tachogeneratoren Vollwelle mit EURO-Flansch B10 Mit eigener Lagerung

ISLIKER MAGNETE AG - CH-8450

Induktive Näherungsschalter inductive proximity switches

D-Sub Dualport Steckverbinder D-Sub dualport connectors

MINI 1-Conductor/1-Pin Receptacle Terminal Blocks; 2-Conductor/2-Pin Receptacle Terminal Blocks, Series 2020

Low Profile Antenna. GLONASS 1890 LP/S/FAKRA 3.0 Erz-Nr. / Ord. code Datenblatt / Datasheet GLONASS / GPS / CELLULAR

KBU 4AYM. Kunststoffgehäuse

P 4,6 4,1. Magnetic characteristics (per set) Σl/A = 2,6 mm 1 l e = 7,6 mm A e = 2,8 mm 2 V e = 21,3 mm 3. Approx. weight 0,17 g/set.

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment

AC/DC-Schaltnetzteile 100 W AC/DC Switching Power Supplies 100 W. Merkmale / Features. Eingangsbereich V AC

Überspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden. Circuits using TVS Diodes

asled3000 Dimmbarer High Power LED-Treiber

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x

1000 Watt Power Supply Single Output Series AK-1000

GK-Serie MONOVOLT. DC/DC-Wandler

SPIRA Power Sections. Specifications Handbook

I-Energieversorgung I-Power Supply

Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

FMC. Features. Product Range

Ceramic tubular trimmer capacitors with metal spindle for PCB mounting

1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid. Generic specification: IEC , IEC

SFH 900 SFH 900. Miniatur-Reflexlichtschranken Miniature Light Reflection Switches

CABLE TESTER. Manual DN-14003

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3

CONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP

Shock pulse measurement principle

Pilot Project Biogas-powered Micro-gas-turbine

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

IDG. Drehzahlsensor / Speed Sensor

technical documents for extraction and filter devices type series 1000

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

LWL Transceiver 9 x 1 SIP 650nm

Transkript:

ISA-PLAN - Precision Resistor Type PBV Spec Sheet R361-1/2 July 97 Technical Data Resistance range 0.5 mohm - 1 Ohm Tolerances 0.5 %, 1 %, 5 % Temperature coefficient ( R > 10 mohm ) < 30 ppm/k ( 20 C to 60 C ) Applicable temperature range -55 C to +125 C Load capacity 3 W / 10 W with heatsink provided Thermal resistance to aluminum base plate Rth < 3 K/W Thermal resistance to ambient Rth < 15 K/W Dielectric withstanding voltage 500 V AC Inductance ( R = 50 mohm ) < 5 nh Stability ( nominal load at 70 C ) deviation < 0.5 % after 2,000 h Remarks: - Standard resistance values according to E12 with the additionel values of 2 and 5 - Minimum quantity of other values on request - Tolerance 0.5% for values from 4,7 mohm The four-terminal resistor type PBV derived from type PBH is especially designed for the low impedance range, in order to obtain lowest temperature coefficient values, and in order to guarantee the independence of the resistance value from the soldering quality. The use of the precision resistance material MANGANIN combined with a highly temperature resistant and humidity insusceptible Duroplast cover as well as optimization of layout and lines result in a high longterm stability, low temperature coefficient and low inductance. The shape is compatible with the latest power transistors. The resistor is mounted through a center bore or spring clamp to a heatsink, whereby the large area of the base plate will provide excellent heat transfer. The low thermal resistance between resistor foil and aluminum base plate warrants for a low temperature rise at nominal load in this configuration and permits transient overloading up to one magnitude. The resistor is ideally suited for applications in power electronic and control technique, as most applications at inductive loading will require operation with switched power regulating units. Short connection distances and small dimensions at high load capacity and low inductance are a prerequisite to obtain high switching frequencies. 1 P / P Nenn 0.75 0.5 0.25 0 20 40 60 80 100 120 power derating curve T G / [ o C] 0.2-40 -20 20 40 60 80 100 120-0.2 R/R 20 [%] T [ o C] -0.4 Temperature dependence of the electrical resistance of ISA-PLAN Resistors dimensions (mm)

Spec Sheet R361-2/2 July 97 ordering example: PBV - R001 - F1-1 type resistance value terminal tolerance PBV 1 mohm F1 1 % ( Technical modifications reserved ) ISABELLENHÜTTE Heusler GmbH KG 35664 Dillenburg P.O.Box 1453 Phone ++49 27 71/9 34-0 Telefax ++49 27 71/2 30 30

ISA-PLAN - Präzisionswiderstände / Precision resistors Technische Daten / technical data Widerstandswerte Resistance values 0,5 mohm - 1 Ohm Toleranz Tolerance 0.5 %, 1 %, 5 % Temperaturkoeffizient(MANGANIN ) Temperature coefficient (tcr) < 30 ppm/k ( 20 C to 60 C ); > R010 Temperaturbereich Applicable temperature range -55 C to +125 C Belastbarkeit Load capacity 3 W 10 W Kühlkörpermontage / with heatsink provided Wärmewiderstand zur Umgebung(R th ) Innerer Wärmewiderstand zum Aluminium Substrat (R thi ) Thermal resistance to ambient(r th ) Thermal resistance to aluminium substrat (R thi ) < 15 K/W Isolationsspannung Dielectric withstanding voltage 500 V AC Induktivität (100 mohm) Inductance (100 mohm) < 10 nh Stabilität (Nennlast) Abweichung T K = Kontaktstellentemperatur Stability (nominal load) deviation T K = Terminal temperature < 3 K/W < 6 K/W for R < 2 mohm < 0.5 % nach/after 2000 h (T K = 70 C) Merkmale / features 3 W Dauerleistung / 10 W bei Kühlkörpermontage 3 W permanent power / 10 W with heatsink provided Vierleiteranschluss des Widerstands Four terminal connection of the resistor Sehr hohe Pulsbelastbarkeit 2 Joule für 10 ms High pulse power rating 2 Joule for 10 ms Sehr gute Langzeitstabilität Excellent long term stability Applikationen / application Leistungsmodule Power modules Frequenzumrichter frequency converters Schaltnetzteile Switch mode power supplies Abmessungen (mm) / dimensions (mm) / 4

TK, Lastminderung und Langzeitstabilität / TCR, power derating and long term stability Temperaturabhängigkeit des elektrischen Widerstandes von MANGANIN -Widerständen Temperature dependence of the electrical resistance of MANGANIN -resistors Lastminderungskurve für PBV montiert auf Kühlkörper Power derating curve for heatsink mounted PBV montiert auf Kühlkörper /heatsink mounted R > 2mOhm; P= 10W ohne Kühlkörper / without heatsink (P = 3 Watt) montiert auf Kühlkörper/heatsink mounted R < 2mOhm; P= 10W Langzeitstabilität von Manganin Widerständen bei 140 C Long term stability of Manganin - resistors at 140 C 2 / 4

Montagehinweis Maximal zulässiges Anzugsmoment für Schrauben M3: 1 Nm Assembly instruction Maximum torque for M3 screws: 1 Nm Beschriftung / Marking Lötprofil Vorschlag / Recommended solder profile Wellenlöten Wave soldering Temperatur 260 C 255 C 217 C Zeit (s) peak 40 90 RoHS 2002/95/EG konform seit 01.01.2005 Ausführliche Informationen erhalten Sie auf unserer Homepage: www.isabellenhuette.de RoHS 2002/95/EC compliance since 01.01.2005 For more information please visit our website: www.isabellenhuette.de Verpackungsinformationen Packaging INFORMATION Stangenmagazin/Tube Anzahl Bauteile/Parts per tube 25 Stück/pieces Bestellbezeichnung / ordering code PBV-R0005-F1-0.5 Typ Widerstandswert Anschlüsse Toleranz Type Resistance value terminal Tolerance PBV 500 µohm F1 0.5 % Gewährleistung Alle Angaben über Eignung, Verarbeitung und Anwendung unserer Produkte, technische Beratung und sonstige Angaben erfolgen nach bestem Wissen, befreien den Käufer jedoch nicht von eigenen Prüfungen und Versuchen. Warranty All information regarding the suitable, workability and applicability of our products, all technical advice and other information are provided to the best of our knowledge and belief, but shall not discharge the buyer from his own examinations and tests. 3 / 4

Grenzkurve für maximale Pulsenergie bzw. Pulsleistung für Dauerbetrieb Diagram of pulse energie. Maximum puls energy resp. pulse power for continous operation 10000 1000 Die dargestellte Kurve gilt für den Widerstandswert R0005. Für andere Werte kann die Kurve im unteren Bereich ggf. anders verlaufen, so dass in Grenzbereichen eine separate Qualifikation erfolgen sollte. This curve is only valid for the resistance value R0005. The progression of the curve in the lower range could be different for other resistance values. Therefore a separate qualification should be made in thresholds. Spezification/Spezifikation Parameters Test Conditions Specification Typical data Maximum Temperature for full power operation ( R > 2 mohm ) 70/90 C 65/95 C 95 C Working Temperature -55 to 125 C -55 to 125 C -55 to 125 C Thermal Shock MIL-STD-202 method 107-B1 0.1 % 0.1 % Overload MIL-R-26E (5 times rated power, 5 sec) 0.2 % 0.1 % Solderability MIL-STD-202 method 208 > 95 % coverage > 95 % coverage Resistance to Solvents MIL-STD-202 method 215, 2.1a, 2.1d no damage no damage Low Temperature Storage and Operation MIL-STD-26E 0.1 % 0.03 % Terminal Strength MIL-STD-202 method 211 50N, 0.02 % 0.02 % Resistance to Soldering Heat MIL-STD-202 method 210 0.1 % 0.02 % Moisture Resistance MIL-STD-202 method 106 0.1 % 0.01 % Shock MIL-STD-202 method 213-A 0.2 % 0.1 % Vibration, High Frequency MIL-STD-202 method 204-B 0.2 % 0.05 % Life MIL-STD-26E 0.2 % 0.1 % Storage Life at Elevated Temperature MIL-STD-202 method 108-F 0.3 % 0.2 % High Temperature Exposure 140 C, 2000 h 0.2% 0.2 % Current Noise MIL-STD-202 method 308 0.01 % 0.001 % Voltage Coefficient (%/V) MIL-STD-202 method 309 linearity error less than 120dB Resistance Temperature Characteristic MIL-STD-202 method 304 (20-60 C) < 30 ppm/k < 30 ppm/k Thermal EMF 0-100 C 2 µv/k max. 2 µv/k Frequency Characteristic inductivity < 10 nh < 10 nh 4 / 4 Isabellenhütte Heusler GmbH & Co. KG Eibacher Weg 3-5 - D-35683 Dillenburg - Telefon / Phone +49 (0) 27 71 9 34-0 - Fax: +49 (0) 27 71 2 30 30