VS tW. USER MANUAL BEDIENUNGSANLEITUNG

Ähnliche Dokumente
Power Supply ND Series. USER MANUAL BEDIENUNGSANLEITUNG

linea m mounting SET USER MANUAL BEDIENUNGSANLEITUNG

PS XLR CON. USER MANUAL BEDIENUNGSANLEITUNG

PS XLR CON. USER MANUAL BEDIENUNGSANLEITUNG

linea s RGB RGBW USER MANUAL BEDIENUNGSANLEITUNG

tectum m RGB RGB USER MANUAL BEDIENUNGSANLEITUNG

Series. USER MANUAL BEDIENUNGSANLEITUNG

linea s purewhite purecolor USER MANUAL BEDIENUNGSANLEITUNG

funis m surface purewhite

tectum m purewhite purecolor USER MANUAL BEDIENUNGSANLEITUNG

funis m square 2000 purewhite

X-LED Line 7.5 RGB. USER MANUAL BEDIENUNGSANLEITUNG

X-LED Mesh 7.5 RGB. USER MANUAL BEDIENUNGSANLEITUNG

funis m square purewhite

linea m hpc outdoor RGB RGBW

linea m hp outdoor purewhite purecolor

funis m round 2000 purewhite

coma l tunablewhite USER MANUAL BEDIENUNGSANLEITUNG

scriptus m USER MANUAL BEDIENUNGSANLEITUNG

tantulus xhp indoor tunablewhite

tantulus eco indoor purewhite purecolor

tantulus 3 eco indoor purewhite purecolor

The luminaire must be installed and main - tained by a suitably qualified person in compliance with latest installation and safety regulations.

Aufbaudose mit Schalter Spacing box with switch. Montageanleitung mounting instructions

DATENBLATT / DATASHEET

Wandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply

tantulus hp outdoor purewhite

Electrical tests on Bosch unit injectors

Qualitätsmanagement-Handbuch Serviceinformation: _Serviceinformation H0201_1_Batterietrennschalter.doc Formblatt. ÜS;Linearlifte AL1

LED Treiber: Anschlussschemata LED driver: connection diagrams

HEAG 151, 152, 153, 154 Digital Converter

Outdoor-Tasche. Operating Instructions Bedienungsanleitung GB D

WE-EF LEUCHTEN. Montage- und Wartungshinweise für Linear-Wandleuchten Serie VLR100 LED

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Rosado, Weiß, V AC/50-60Hz, 1x max. 40,00 W + 60,00 W.

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Arianna, Weiß, V AC/50-60Hz, 1x max. 80,00 W. Technische Daten.

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Aviar, Weiß-satiniert, V AC/50-60Hz, 40,00 W. Technische Daten.

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

Electrical testing of Bosch common rail piezo injectors

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Giorgia, Weiß, V AC/50-60Hz, 25,00 W. Technische Daten.

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Cube, Dunkelgrau, V AC/50-60Hz, 1x max. 25,00 W. Technische Daten.

Electrical testing of Bosch common rail Injectors

WE-EF LEUCHTEN. Montage- und Wartungshinweise für Deckenaufbauleuchten DAC200 LED

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

Datenblatt data sheet

Bedienungsanleitung. User Manual

Installationsanleitung / installation manual - DIMMbox

(825M) 2-Draht-Sender

1 Allgemeine Information

DATENBLATT / FACT SHEET

Serie B.121. B.121.V Bremse mit Lüfter brake with fan. B.121.R Bremse mit Radiator brake with radiator. B.121 Bremse brake. C.121 Kupplung clutch

DATENBLATT / FACT SHEET

Hinweisblatt indication sheet

Universe Square Suspension

Produktdatenblatt. Artikel Nr.: Pendelleuchte, Filo Ball, Silber, V AC/50-60Hz, 1x max. 40,00 W. Technische Daten.

IR RECEIVER Bedienungsanleitung User s Manual

Bedienungsanleitung User Manual. System AED Plus

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS

IDG. Drehzahlsensor / Speed Sensor

DATENBLATT / FACT SHEET

Outdoor Netzteil 24 VAC Installationsanleitung

PoE Kit Mounting Instructions SG/XG 210/230/310/330/430/450

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten.

VIDEO CALL CAMERA G-VCAM-01

Montage-Anschluss-Anleitung

Westfalia Bedienungsanleitung. Nr

DATENBLATT / FACT SHEET

Bedienungsanleitung Regelbare Netzgeräte MRNG-Serie

DATENBLATT / FACT SHEET

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Weiß, 12V AC/DC, 1x max. 50,00 W. Technische Daten. Charakteristik.

Lithium Fotoakku Ladeset Lithium Photo rechargeable battery Set

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type

LED Treiber: Anschlussschemata LED driver: connection diagrams

EX-1163HM. 4 Port USB 2.0 Metall HUB für Trägerschiene. 4 Port USB 2.0 Metal HUB for Din-Rail. Anleitung. Manual

Zehnder CLD. Housing for walls, floors and ceilings

Datenblatt data sheet

DE Gebrauchsanleitung / Montageanleitung 2 EN Instructions for use / assembly instructions 3 E / S / Metris S /

Electrical testing of Bosch common rail solenoid valve (MV) injectors

SW-MOTECH GmbH & Co. KG Ernteweg 8/ Rauschenberg Germany. Tel. +49 (0) 64 25/ Fax +49 (0) 64 25/

Zehnder ComfoWell 220

CS 80 MAGNEO Zusatzset Sensorik add. set for safety sensor DORMA IRIS ON ACTIV8 ONE ON. Jupiter. Art Motion

Einbauanleitung / Installation Instructions Kit CM44xR

Netzgerät compact Power Supply Unit compact

Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range

Drehmomentvervielfältiger torque multiplier

BRUUDT Kennzeichenhalter für die Honda NC750X ab 2016 BRUUDT Tail Tidy for the Honda NC750X 2016 and onwards.

Datenblatt data sheet

ELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/

OPERATING INSTRUCTIONS

Transkript:

VS 600-36-tW USER MANUAL BEDIENUNGSANLEITUNG www.biontechnologies.com

USER MANUAL VS 600-36-tW Safety Instructions Devices must be installed by qualified personnel in compliance with all pertaining regulations. Always refer to the technical parameters in the data sheet. All items are subject to technical modification. Refer to the attached User Manual as a basis for correct use. Protect device against moisture. Ensure the correct internal wiring according to installation manual! Note! Before attempting any work, make sure device is separated from main power. Make sure protection against line voltage shock is provided during installation. Note that adjacent parts or devices must be temperature proof up to 90 C. Do not operate electronic devices with inductive consumers (fluorescent lamps, gas discharge lamps, ventilators etc.) in the same electric circuit. Activation of inductive consumers can cause damage to the operating device. Do not place heat insulation material on the device. Mind the operating temperatures of the device according to the technical data sheet. Before drilling the mounting holes or cutting the lamp cutout, take precautions not to harm or damage any power lines underneath. Note and mind voltage label on the device. Do not cross primary and secondary lines. Do not interconnect secondary lines of power supply blocks. The device must only be powered up with lamp connected! Connecting the lamp to the powered-up device can cause damage to the lamp! (voids product warranty!) 2 www.biontechnologies.com

Scope of delivery Check completeness of supplied device immediately after receipt. In delivery included: User Manual VS 600 If you detect any transportation damage or differencies between specified packing contents and your unpacked delivery, please contact your dealer immediately. www.biontechnologies.com 3

Technical Data Dimensions 350 mm x 320 mm x 90 mm [B x T x H] 13.78 in x 12.60 in x 3.55 in [B x T x H] Control 0-10 V, DALI, DMX, POT Input Voltage Power supply: internal 100-240, 277 VAC (50-60 Hz) 127-431 VDC Power Consumption Max. 660 W Power Factor Correction > 0,94 Protection Class I Output Voltage 36 VDC Inrush COLD START 70A(t=1000 s measured at 50% I) at 230VAC; width peak Per NEMA 410 Operating Temperature Range -20 C / +40 C -4 F / +104 F Housing Steel-sheet, powdercoated Housing Color(s) White (RAL 9010) Weight 8,1 kg (17.86 lbs) Ingress Protection IP20 Environment indoor Warranty Certification 4 www.biontechnologies.com 24 Months

Engineering Drawing www.biontechnologies.com 5

Wiring Input rail mounted terminal block, 0.25 mm² - 4 mm² (22 AWG - 12 AWG) Output rail mounted terminal block, 0.25-4 mm² (22 AWG - 12 AWG) 6 www.biontechnologies.com

Mounting 1. Remove the device from the shipping box and check for completeness and possible damage. 2. Loosen the screws on the housing and remove the cover 3. Break the selected parts of the perforation. In accordance with the required cables to break the selected parts of the perforation to use your cable connection. Case perforation d = 22 mm [0.86 in]. Attention: Device must only be mounted in the positions (see picture) as indicated. www.biontechnologies.com 7

4. Mounting: Drill four mounting holes into mounting surface as indicated. Mind the drill markings in the drawing and check mounting surface for firmness and back venting of device. All measures given in millimeters. 5. Finish your work: Connect fixture line, data line and power line according to installation instructions (point 6). Check your connections and close the cover using the 14 screws provided (max. torque 8 Nm). Device must be used with closed cover only. 8 www.biontechnologies.com

Commissioning 1. Wiring tantulus hp2 tunablewhite www.biontechnologies.com 9

2. Setup 1. Mode of operation DMX DALI 2. Set Led groups 1-4L CCWW für tantulus tunablewhite 10 www.biontechnologies.com

Operation 1. DALI 1. Mode of operation DALI 2. Set Led groups e.g. for tantulus tunable White 1-4L CCWW www.biontechnologies.com 11

2. DMX-addressing For addressing the power supply the addressing device scriptus m can be used. Default value is DMX-Address 1. 12 www.biontechnologies.com

3. 0-10v Diming Calibration to Source: 1. Press calibration button to start 2. Set minimum Level to the signal input of the power supply 3. Press calibration button to teach in the Level. 4. Set maximum Level to the signal input of the power supply. 5. Press calibration button to teach in the Level and finish the calibration. The power supply is calibrated to the signal level of your source now. Attention! Minimumlevel on the analog input -> 100% intensity Maximumlevel on the anlaog input -> 0% intensity www.biontechnologies.com 13

4. System Overview 1. 2. 3. 4. Power Supply Leader Cable tantulus 3 optional: Connection Cable or further tantulus 3 with end to end connection 5. Fuses Used fuses: North America: 2,8 A, slow, ¼ x 1¼ Europe: 5A, slow, ¼ x 1¼ 14 www.biontechnologies.com

Maintenance Clean device from dirt and residue regularly. Use solvent-free cleaning agents only and do not employ aggressive chemicals or high pressure cleaner. Operate device only after complete drying. Use in low-dust areas Keep ventilation slots clean, check frequently Conformity Manufacturer Bion Technologies GmbH Lindberghstrasse 15 86343 Koenigsbrunn Tel: +49 (0)8231/95787-0 Fax: +49 (0)8231/95787-29 www.biontechnologies.com info@biontechnologies.com YouTube: http://www.youtube.com/biontechnologies All rights reserved / Subject to change / Specifications may change without notice www.biontechnologies.com 15

BEDIENUNGSANLEITUNG VS 600-36-tW Sicherheitshinweise Anschluss und Bedienung dieses Geräts sollte ausschließlich von qualifiziertem Fachpersonal in Übereinstimmung mit allen geltenden Vorschriften erfolgen. Beachten Sie immer die technischen Daten auf dem Datenblatt. Technische Änderungen vorbehalten. Die beigefügte Gebrauchsanleitung ist Voraussetzung für den ordnungsgemäßen Gebrauch. Gerät vor Nässe schützen. Die Aderbelegung im inneren des Gerätes ist gemäß Installationsanweisung zu beachten! Achtung! Vor Beginn der Arbeiten Gerät vom Netz trennen. Der Schutz gegen elektrischen Schlag ist beim Einbau sicherzustellen. Beim Einbau ist darauf zu achten dass benachbarte Bauteile einer Temperatur von 90 C standhalten. Elektronische Betriebsgeräte nicht gemeinsam mit induktiven Lasten (Leuchtstofflampen, Entladungslampen, Ventilatoren usw.) im gleichen Stromkreis betreiben. Beim Schalten induktiver Lasten können Defekte am Betriebsgerät entstehen. Wärmedämmung darf nicht auf dem Betriebsgerät liegen. Beim Einbau ist auf die, in den technischen Daten angegebenen, Betriebstemperaturen zu achten. Vor dem Bohren oder Ausschneiden der Befestigungslöcher bzw. des Geräteausschnittes ist darauf zu achten, das eventuell darunter liegenden Netzleitungen nicht beschädigt werden. Spannungskennzeichnung auf dem Betriebsgerät beachten. Ein einwandfreier elektrischer Übergang ist beim Anschließen der Leuchte an das Betriebsgerät zu gewährleisten. Primär- und Sekundärleitungen müssen kreuzungsfrei verlegt werden. Sekundärleitungen mehrerer Betriebsgeräte dürfen nicht miteinander verbunden werden. Das Betriebsgerät darf nur mit angeschlossener Leuchte unter Spannung gesetzt werden! Wenn die Leuchte unter Spannung mit dem Netzteil verbunden wird kann die Leuchte beschädigt werden! (Kein Gewährleistungsfall) 16 www.biontechnologies.com

Lieferumfang Packen Sie alle Teile aus. Prüfen Sie den Verpackungsinhalt auf sichtbare Transportschäden. Prüfen Sie, ob der Verpackungsinhalt vollständig ist. Im Lieferumfang enthalten: Bedienungsanleitung VS 600 Wenn Sie Transportschäden oder Unstimmigkeiten zwischen dem hier angegebenen Lieferumfang und Verpackungsinhalt feststellen, informieren Sie unverzüglich Ihre Verkaufstelle. www.biontechnologies.com 17

Technische Daten Abmessungen 350 mm x 320 mm x 90 mm [B x T x H] 13.78 in x 12.60 in x 3.55 in [B x T x H] Steuerung 0-10 V, DALI, DMX, POT Eingangsspannung Netzteil: intern 100-240, 277 VAC (50-60 Hz) 127-431 VDC Wirkleistungsaufnahme Max. 660 W Blindleistungskompensation > 0,94 Schutzklasse I Ausgangsspannung 36 VDC Einschaltstrom Kaltstart 70A(t=1000 s gemessen an 50% I) @ 230VAC; mit Peak nach NEMA 410 Betriebstemperaturbreich -20 C / +40 C -4 F / +104 F Gehäuse Stahlblech, pulverbeschichtet Gehäusefarbe(n) Weiß (RAL 9010) Gewicht 8,1 kg (17.86 lbs) Schutzart IP20 Umgebung indoor Gewährleistung Zulassungen 18 www.biontechnologies.com 24 Monate

Technische Zeichnung www.biontechnologies.com 19

Verkabelung Anschluss Klemmblock, 0,25 mm² - 4 mm² (22 AWG - 12 AWG) Ausgang Reihenklemmen, 0,25-4 mm² (22 AWG - 12 AWG) 20 www.biontechnologies.com

Montage 1. Entnehmen Sie das Gerät der Verpackung und prüfen Sie Ihre Lieferung auf Vollständigkeit und Beschädigungen. 2. Lösen Sie die Schrauben auf dem Deckel des Gerätes und entfernen Sie die Abdeckung. Deckelverschraubung: 14 Schrauben (2,9 x 6,5 T10) 3. Herausbrechen der Kabelöffnung: Brechen Sie entsprechend den benötigten Leitungen die markierten Teile aus der Perforation heraus um Ihre Kabelverschraubung einzusetzen. Gehäusedurchbruch d = 22 mm [0,86 in]. ACHTUNG: Gerät darf ausschließlich in diesen Positionen (siehe Skizze) montiert werden www.biontechnologies.com 21

4. Befestigung: Bohren Sie, wie vorgegeben, am vorgesehenen Montageplatz vier Befestigungslöcher. Beachten Sie hierzu die Bohrmarkierungen in der Skizze und achten Sie auf entsprechende Untergrundfestigkeit sowie Hintergrundbelüftung des Gerätes. Alle Maße sind in Millimeter angegeben. 5. Abschlussarbeiten: Schließen Sie die Leuchtenleitung, Datenleitung und die Netzleitung gemäß Inbetriebnahmeanweisung (Punkt 5 - Bedienung) an. Prüfen Sie Ihre Anschlüsse und verschließen Sie den Deckel mit den mitgelieferten 14 Schrauben (max. Drehmoment 8 Nm). Gerät darf ausschließlich mit verschlossenem Deckel betrieben werden. 22 www.biontechnologies.com

Inbetriebnahme 1. Anschluss tantulus hp2 tunablewhite www.biontechnologies.com 23

2. Setup 1. Betriebsart auswählen DMX DALI 2. Leuchtengruppierung 1-4L CCWW für tantulus tunablewhite 24 www.biontechnologies.com

Installation and commissioning 1. DALI 1. Betriebsart auswählen DALI 2. Leuchtengruppierung z.b.: für tunable White 1-4L CCWW www.biontechnologies.com 25

2. DMX-Addressierung Die Adressierung des Netzteils kann durch das Adressiergerät scriptus m vorgenommen werden. Standardeinstellung ist DMX-Adresse 1. 26 www.biontechnologies.com

3. 0-10v Dimmung Kalibrierung der Signalpegel: 1. Drücken Sie den Kalibrierungsknopf 1x um den Abgleich zu starten. 2. Legen Sie die Minimalspannung am Signaleingang des Netzteils an. 3. Bestätigen Sie den Signalpegel durch 1x drücken des Kalibrierknopfs. 4. Legen Sie die Maximalspannung am Signaleingang des Netzteils an. 5. Bestätigen Sie den Signalpegel wieder durch 1x drücken des Kalibrierknopfs. Das Netzteil ist nun auf Ihre Anlagenpegel konfiguriert und ist analog steuerbar. Achtung! Minimalspannung Eingang -> 100% Intensität Maximalspannung Eingang -> 0% Intensität www.biontechnologies.com 27

4. Systemaufbau 1. 2. 3. 4. Netzteil Anschlusskabel tantulus 3 optional: Verbindungskabel oder weitere tantulus 3 end to end 5. Sicherungen Verwendete Feinsicherungen: Nord Amerika: 2,8 A, träge, ¼ x 1¼ Europa: 5A, träge, ¼ x 1¼ 28 www.biontechnologies.com

Wartung + Pflege Gerät regelmäßig mit einem feuchten Tuch reinigen. Verwenden Sie ausschließlich lösungsmittelfreie Reinigungsmittel und verwenden Sie keine Chemikalien. Achten Sie auf eine staubarme Umgebung Lüftungsöffnungen regelmäßig kontrollieren und säubern Konformität Hersteller Bion Technologies GmbH Lindberghstrasse 15 86343 Koenigsbrunn Tel: +49 (0)8231/95787-0 Fax: +49 (0)8231/95787-29 www.biontechnologies.com info@biontechnologies.com YouTube: http://www.youtube.com/biontechnologies All rights reserved / Subject to change / Specifications may change without notice www.biontechnologies.com 29

Powered by TCPDF (www.tcpdf.org) Lindberghstrasse 15 86343 Koenigsbrunn Tel: +49 (0)8231/95787-0 Fax: +49 (0)8231/95787-29 www.biontechnologies.com info@biontechnologies.com YouTube: http://www.youtube.com/user/biontechnologies 2016, BION TECHNOLOGIS GMBH All rights reserved / Subject to change / Specifications may change without notice