TRICOR Series TCM Coriolis Mass Flow Meters

Ähnliche Dokumente
TRICOR Serie TCM Coriolis Massendurchflussmesser

Ex emergency pull-wire switches // Ex ZS 75 S

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Quality control and process tracking. From concept to acceptance.

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

direktgesteuert direct acting

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

A P max. 16bar P R max. 64bar R P max. 16bar

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

2/2-way solenoid valve - Type 218

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

direktgesteuert direct acting

P A max. 100bar A P max. 16bar

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.

direktgesteuert direct acting

Magnetic inductive flow sensors

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Ex solenoid interlocks // Ex AZM 415

Signal Processing Präzisions-Interpolator / Splitter Wandlung von SinCos-Gebersignale in TTL- und HTL-Ausgangssignale

Programmierbares Multisystem Serie PMS XPULSE

2/2-way solenoid valve - Type 239

Umschaltventile Magnete

ABB i-bus EIB. EIB Power Supply Units

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Datenblatt. P-series PDU 2.5/4/4AN

Umschaltventile Magnet

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...

INCLUDES: Fully assembled 4 wheels for mobile use Power cable

2/2-way plastic solenoid valve - Type 104

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

LORENZ MESSTECHNIK GmbH

Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung

CANNON STANDARD Seite 1 von 5. CAI Industrial Circular Connector

DMK 331P DRUCK & TEMPERATUR LEITENBERGER GMBH. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W

Lufft UMB Sensor Overview

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

2/2-way plastic solenoid valve - Type 110

Signal Processing Präzisions-Sinusvervielfacher Wandlung von SinCos-Gebersignale in vervielfachte SinCos-Ausgangssignale

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft

servogesteuert pilot operated

Westenberg Wind Tunnels

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Ex position switches with/without safety function // Ex 12

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator

DOL 12. DOL 12 is a simple temperature sensor encapsulated by plastic material and suitable for usage in environments requiring a sturdy design.

Unterschiedliche Chipgrößen / Different scan areas. Unterschiedliche Bildwechselfrequenzen / Different frame rates

M12 Verteilerinsel / M12 Splitter box

LORENZ MESSTECHNIK GmbH

Magnetic inductive flow sensors

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC

CAN-Bus-Systems. Microprocessor-controlled Can-Bus-node with digital and analog signal in- and outputs.

Cleanroom Fog Generators Volcano VP 12 + VP 18

Zehnder CLD. Housing for walls, floors and ceilings

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 286 Type 286. fremdgesteuert externally controlled

Overview thermostat/ temperature controller

Control shut-off butterfly valves DN 50 DN 400 PN

Vortex flow sensors. Series VVX. Type VVX20. Type VVX15

Attenuator and Distribution System Zehnder ComfoWell 220

ISLIKER MAGNETE AG - CH-8450

Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range

Optik Konverter für Profibus Optical converter for Profibus


LORENZ MESSTECHNIK GmbH

TW-75-IP40Trackball. Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40. Description

CR2013. CompactModule. E/A-Modul digital und analog für System R 360. CANopen. Schnittstelle. Betriebsspannung V DC.

Magnetic inductive flow sensors

Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert

Certificate of conformity Generating unit, NS-protection

Zubehör LED Accessories LED

Technische Daten / Technisches Merkblatt (nach pren ) ECHOGRAPH 1016B (Best.-Nr )

ELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/

Inhaltsverzeichnis Index

Induktive Näherungsschalter inductive proximity switches

Datasheet. Page 1 of 7

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1)

LORENZ MESSTECHNIK GmbH

Certificate of conformity Generating unit, NS-protection

Q-Motor Multifunktionsmotor. Q-motor multi-function motor

Stecksystem connector system: ESP

M12 AC-POWER-Steckverbinder S-Kodierung M12 AC-POWER-connectors S-coded

Snap-in switch for switches PSE, MSM and MCS 30

Transkript:

TRICOR Series TCM Coriolis Mass Flow Meters Technical Datasheet TCM_E68_D_EN_150122_E002

TRICOR - Coriolis Mass Flow Meters Description The TRICOR Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different measuring instruments. The TRICOR Mass Flow Meters do not contain any moving parts and consequently are suited for polluted media as well. According to the requirements the TRICOR Mass Flow Meters are available as compact versions with on site display and remote version with electronics in a wall mount or panel mount housing. For the compact version an additional remote display (TRD 8001) is available. Features Integrated pressure compensation available Robust sensor design to minimize downtime Customizable installation length Mass flow, volumetric flow, density and temperature (all in one) High pressure designs available - up to 345 bar/5000 PSI High sensitivity for best meter performance even under demanding process conditions Integrated meter diagnostics Calibration: DAkkS-Accreditation as per DIN EN ISO/IEC 17025:2005 Special calibrations for an oil viscosity up to 100 mm 2 /s possible FAST LANE availability for flexible and fast deliveries (5 days express deliveries) 2

Coriolis Mass Flow Meters - TRICOR Overview Compact version Compact version Exd housing: Wall mounted (remote version) Housing: Panel mounted (remote version) Version with TCE 6000 and TRD 8001 Remote Display TRD 8001 3

TRICOR - Coriolis Mass Flow Meters Technical Data - TCM Transducer TCM 0325 TCM 0650 TCM 1550 TCM 3100 TCM 5500 TCM 7900 TCM 028K TCM 065K TCM 230K Max. Flow Rate (kg/h) 325 650 1550 3100 5500 7900 28000 65000 230000 Max. Flow Rate (lb/min) 11 22 55 110 200 290 1030 2390 8400 Basic Accuracy (0.1% o.r.) ±0.1 Zero Stability (% f.s.) ±0.01 Repeatability (% o.r.) ±0.05 Density Measuring Range 0-2500 kg/m³, 2.5 g/cm 3 (higher ranges on request) Density Accuracy ±1.0 kg/m 3, ±0.001 g/cm 3 (special calibration on request) Density Repeatability ±0.5 kg/m 3, ±0.0005 g/cm 3 Temperature Accuracy Temperature Repeatability ±1 C ±0.5 % of reading (±1.8 F ±0.5 % of reading) ±0.2 C (±0.36 F) Process and Ambient Process Connections Max. Pressure Standard (Option) Pressure Drop at Max. Flow H20 Process Temperature (non Ex) Process Temperature (Ex) High Temperature (Ex) (only remote version) Ambient Temperature female thread 1/2 adaptors for flanges, diary and tri-clamp 200 bar/2900 PSI (345 bar/5000 PSI) for detail information please contact us flanges EN1092, ANSI B16.5, DIN2512 100 b ar/1450 PSI -40 C... +100 C (-40 F... +212 F) (standard) / -60 C... +150 C (-76 F... +302 F) (optional) meter mount -40 C... +70 C (-40 F... +158 F) n/a remote version -40 C... +70 C (-40 F... +158 F) (T4) -40 C... +100 C (-40 F... +212 F) (T3) T <= +135 C (+275 F) (T3); T <= +150 C (+302 F) (T2) -40 C... +70 C (-40 F... +158 F) Storage Temperature -40 C... +100 C (-40 F... +212 F) Electr. Connections Remote Electr. Connections Meter Mount screw type terminals none (internally connected to the electronics) Ingress Protection IP65 (IP67 on request) General Tube Arrangement 2 serial 2 parallel 2 serial 2 parallel 2 parallel 2 parallel 2 parallel 2 parallel 2 parallel Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 28 mm 43 mm Tube Material Housing Material Dimensions 1.4404 / AISI 316L 1.4404 / AISI 316L see drawings 1.4301 / AISI 304 Stated accuracy combines the effects of repeatability, linearity, and hysteresis. 4

Coriolis Mass Flow Meters - TRICOR Technical Data - TCE 8000 Transmitter General Display Supply Voltage Programming Interface graphic, 132 x 32 dot 24 V DC, ±20 % or 90 264 V (version dependent) via front keyboard RS 485 (MODBUS-RTU), Option HART, other options on request EMC according to EN 61000-6-4 and 61000-6-2 Power Consumption ExD Housing: Wall-mounted Dimensions Electrical Connections Cable Glands Housing Material Protection Class Weight Temperature Housing: Panel-mounted Dimensions Electrical Connections Housing Material Protection Class Weight Temperature Analog Output Current Outputs (2x) Resolution Linearity Temperature Drift Load Output Value Pulse Output Frequency Range Output Signal Status In-and Output Status Output Control Input Analog Input (option) Input Type Resolution Linearity Temperature Drift Supply Voltage max. 6 W see drawing cage clamp terminals for 7-13 mm cables aluminium diecast IP65 (IP67 on request) 3.8 kg/8.3 lb with 3 m cable ambient: -40 C up to +70 C (-40 F... +158 F) storage and transport: -40 C up to +80 C (-40 F up to +176 F) see drawing cage clamp terminals Noryl front: IP50, rear: IP30 0.4 kg/0.88 lb operation: 0 C to +60 C (32 F to +140 F) storage and transport: -20 C up to +70 C (-4 F up to +158 F) 4... 20 ma passive, two-wire, isolated 14 bit ±0.05 % of full scale 0.05 % per 10 K < 620 Ω (at 24 V supply) programmable: flow, total, density, temperature 0.5-10000 Hz active push pull output for flow rate push pull programmable programmable 4-20 ma active for two-wire passive pressure sensor 12 bit ±0.05 % of full scale 0.05 % per 10 K > 20 V (at 20 ma sensor current) 5

TRICOR - Coriolis Mass Flow Meters Technical Data - TCE 6000 Transmitter General Supply Voltage 24 V DC, ±20 % Programming Interface via interface RS485, USB (option) EMC according to EN 61000-6-4 and EN 61000-6-2 Power Consumption Connections Housing Material Temperature Protection Class Analog Output Current Output Resolution max. 4 W connectors M12 aluminium diecast operation: -40 C to +70 C (-40 F to +158 F) storage: -40 C to +80 C (-40 F to +176 F) IP65 (IP67) 4... 20 ma active 14 bit Linearity ±0.05 % Temperature Drift Load Output Value Pulse Output Frequency Range Output Signal Status In-and Output Status Output Control Input 0.05 % per 10 K < 800 Ω programmable: flow, total, density, temperature 0.5-10000 Hz active push pull output for flow rate push pull programmable (option) programmable (standard: 1 input/option: 2 inputs) Technical Data - TRD 8001 Remote Display Display Supply Voltage Programming graphic, 132 x 32 dot via interface Interface to TCE RS 485 via front keyboard EMC according to EN 61000-6-4 and 61000-6-2 Dimensions 90 x 120 x 50 mm (h x w x d) Connections Housing Material Protection Class Weight Temperature Wall Mount connectors M12, B coded ABS- FR (plastic, flame retardant) IP64 0.4 kg/0.88 lb operation: 0 C to +60 C (32 F to +140 F) storage and transport: -20 C up to +80 C (-4 F to +176 F) hidden screws 6

Coriolis Mass Flow Meters - TRICOR Ex Certifications ATEX IECEx CSA Ex Zone 1: Group IIC or IIB, T4 Zone 2: II 3G Ex na IIC T4 Gc Zone 1: Group IIC or IIB, T4 Class I, Division 1: Group A, B, C, D, T4 oder Group C, D, T4 Accuracy % 1,5 1 0,5 Accuracy Basic Accuracy + Zero Stability max. Flow current Flow 0-0,5-1 -1,5 0 10 20 30 40 50 60 70 80 90 100 Flow % 7

TRICOR - Coriolis Mass Flow Meters Dimensional Drawing TCM 0325 to TCM 3100 L 22mm 0,87in G D 70mm 2,76in E H 59mm 2,32in A TCM 0325 TCM 0650 TCM 1550 TCM 3100 Sensor Type A C D E H L* G** 214 mm (8.4 in) 214 mm (8.4 in) 350 mm (13.8 in) 350 (13.8 in) 160 mm (6.3 in) 160 mm (6.3 in) 258 mm (10.2 in) 258 mm (10.2 in) M6 10 M6 10 M6 10 M6 10 15 mm (0.6 in) 15 mm (0.6 in) 18 mm (0.7 in) 18 mm (0.7 in) 182 mm (7.2 in) 182 mm (7.2 in) 280 mm (11 in) 280 mm (11 in) 110 mm (4.3 in) 110 mm (4.3 in) 140 mm (5.5 in) 140 mm (5.5 in) G ½ G ½ G ½ G ½ Dimensional Drawing TCM 5500 to TCM 065K L I.D. H C TCM 5500, 7900 TCM 028K TCM 065K Sensor Type B C H L* I.D. Connection** 61 mm (2.4 in) 80 mm (3.5 in) 151 mm (5.4 in) 204 mm (8 in) 253 mm (10 in) 387 mm (18.9 in) 260 mm (10.2 in) 315 mm (12.4 in) 480 mm (32.7 in) 460 mm (18.1 in) 625 mm (24.6 in) 830 mm (32.7 in) B Ø 13 mm (Ø 0.5 in) Ø 23 mm (Ø 0.9 in) Ø 40 mm (Ø 1.6 in) on request on request on request 8 * further lengths on request ** other connections on request

Coriolis Mass Flow Meters - TRICOR Dimensional Drawing TCM 230K 915mm 36.0in Ø 168mm 6.6in ANSI, DIN, threaded, Tri-Clamp, and JIS flanges available Rupture Disk Assembly 1/2" BSPP Female Thread Junction Box Assembly 882mm 34.7in 230mm 9.1in 165mm 6.5in Dimensional Drawing Meter Mount Electronics TCE 8000 (C) 147,40mm 5,80in 203mm 7,99in 146mm 5,75in 166mm 6,54in 110mm 4,33in 118mm 4,65in 9

TRICOR - Coriolis Mass Flow Meters Dimensional Drawing TCE 80xx - W 147,4mm 5,80in 222,5mm 8,76in 191,50mm 7,54in 10,5mm 0,41in 37,5mm 1,48in 75mm 2,95in 42,8mm 1,68in 32,8mm 1,29in 202mm 7,95in 110mm 4,33in 127mm 5,00in 14mm 0,55in 9,3mm 0,36in 19,3mm 0,76in Dimensional Drawing Panel-Mounted Housing (drawing not to scale) A B 83mm 3,27in 8mm 0,31in 143,60mm 5,65in Type A B - - - - - TCE 80** - S 96 mm (3.8 in) 96 mm (3.8 in) - - - - - TCE 80** - L 96 mm (3.8 in) 144 mm (5.7 in) - - - - - 10

Coriolis Mass Flow Meters - TRICOR Dimensional Drawing Connection Head (A) 68mm 2,67in 115mm 4,52in Dimensional Drawing Meter Mount Electronics TCE 6000 (F) 64mm 2,52in 57mm 2,25in 98mm 3,86in 79mm 3,12in 48mm 1,89in 72mm 2,82in 38mm 1,50in 11

TRICOR - Coriolis Mass Flow Meters Dimensional Drawing Remote Display TRD 8001 120mm 4,72in 90mm 3,54in 16mm 0,63in 50mm 1,97in 12

Coriolis Mass Flow Meters - TRICOR Ordering Information TCM Meter (Series TRICOR) TCM X X X X - X X - X X X X - X X X X - Ex - X X Process Connections 1) ANSI flange A* ANSI flange B* DIN flange D* Female thread F* Mechanical Options Medium Temperature Range: -40 C +100 C (-40 F +212 F) S -60 C +150 C (-76 F +302 F) H -40 C +70 C (-40 F +158 F) Ex, compact E Pressure With rupture disc max. 5 BAR (72,5 PSI) Mechanical Design Standard Face to Face-Lenght Standard (other lengths on request) Electronics Options Electronics Type Junction box A Z Z S Meter mount electronics (TCE 8000) C Meter mount electronics (TCE 6000) 2)3) F Interface 4) RS485 (MODBUS RTU) S RS485 (MODBUS RTU) and HART A RS485 (MODBUS RTU) +FF (not with Ex) B FF (Foundation Fieldbus) D RS485 (MODBUS RTU) + USB (only TCE 6000) F Not used Z Supply Voltage 24 V DC D 90 264 V AC M Not used Z Options Pressure compensation +4 20 ma input (TCE 8000) A 8 pin I/O connector (TCE 6000 only) B No option S Ex-Protection ATEX + IECEX zone 1: Group IIC or IIB, T4 ccsaus: Class 1, Div. 1: Group C, D, T4 ATEX zone 2: II3G Ex na IIC T4 Gc Without Ex-protection Special Options NOC (Net Oil Computer) 01 G S S Ex Ex1 Exn 1) Ask KEM/AWL for technically possible flanges 2) Only in the following options: FSDS (5 PIN I/O and RS485 MODBUS RTU or FFDB (5&8 PIN I/O, RS 485 MODBUS RTU, USB) 3) Ex-protection only available in the option Exn 4) Other interfaces on request 13

TRICOR - Coriolis Mass Flow Meters Ordering Information TCE Transmitter (Series 8000) TCE 8 0 X X - X - X X X X - X X - XX For TCM 0325 to TCM 7900 8 0 0 1 For TCM 028K to TCM 065K 8 0 1 1 For TCM 230K 8 0 1 2 Housing Wall mounted Panel mounted Panel mounted, wide for "Ex", "associated equipment" Options Interface 1) RS485 (MODBUS RTU) RS485 (MODBUS RTU) + HART Supply Voltage 24 V DC + 90 264 V AC (only housing S+L) B 24 V DC D 90 264 V AC (only housing W) M Electronic Options Standard Pressure compensation and 4-20mA input Length, Cable 3 Meters ( 10 ft.), Standard (housing W) S 6 Meters ( 20 ft.), (housing W) B 10 Meters ( 33 ft.), (housing W) C 15 Meters ( 49 ft.), (housing W) D 20 Meters ( 65 ft.), (housing W) E D-SUB Connector, (housing L+S) seperate cable required EX-Protection ATEX+IECEX zone 1: Group IIC or IIB, T4 ccsaus: Class 1, Div. 1: Group C, D, T4 ATEX Zone 2: II3G Ex na IIC T4 Gc No Ex-protection Special Options NOC (Net Oil Computer) 01 W S L S A S A N Ex Ex1 Exn 1) Other interfaces on request 14

Coriolis Mass Flow Meters - TRICOR Accessories Connection Cable for TCE 8000-S or TCE 8000-L to TCM Lenght TCC 0 2 - X X 3 Meter (Standard) ( 10 ft.) 0 3 6 Meter ( 20 ft.) 0 6 10 Meter ( 33 ft.) 1 0 15 Meter ( 49 ft.) 1 5 20 Meter ( 66 ft.) 2 0 Additional Accessories IPS9-9 IPS9-14 TRD 8001 TRD-TCE-6-2 TRD-TCE-6-5 TCD 4600 KAB-USB-TCE CON.USB.RS Front cover IP65 for TCE 80**-S-* Front cover IP65 for TCE 80**-L-* Add. Remote display for meter mount version Connection cable TRD-TCE 6000, 2 meter Connection cable TRD-TCE 6000, 5 meter Gauge Volume Totalizer USB Cable, USB to mini USB M12, 2 meter, for TCE 6000 Adaptor cable USB to RS 485, 1.8 meter Flange Adapter for TCM 0325 through TCM 3100 ZA - F X - X X Connections G 1/2" F A Process Connections Technically possible flanges on request * * **: Suitable flanges on request www.tricor ow.com North- and South America: AW-Lake Company 8809 Industrial Drive Franksville, WI 53126 USA Tel.: 800-850-6110 China: TASI Flow Rm. 2429, JinYuan Office Building, No. 36 CN - BeiYuan Road, Beijing 100012 P.R.CHINA Tel.: +86 10 520 037 38 Rest of the world: KEM Küppers Elektromechanik GmbH Liebigstraße 5 85757 Karlsfeld, Germany Tel.: +49 (0)8131 59391-0