1 . 60mm Busbar systems 60mm Sammelschienensystem TYTAN - HR / RH Main protection TYTAN - HR / RH Hauptschutz TYTAN-MAIN PROTECTION consists of a switch disconnector fuse with modern monitoring electronic and the respective MAIN PROTECTION-Relay. A B Standard case: Individual monitoring Every TYTAN-MAIN PROTECTION device will be connected to a MAIN PROTECTION-relay for individual monitoring of it s load circuit. Special case: Collected fault monitoring Therefore 2 TYTAN-MAIN PROTECTION devices will be connected in series and to a MAIN PROTECTION relay. Der TYTAN-HAUPTSCHUTZ besteht aus dem Sicherungslasttrennschalter mit moderner Überwachungs-Elektronik und dem jeweiligen HAUPTSCHUTZ-Relais. A B Im Standardfall: Einzelauswertung Jedes TYTAN-HAUPTSCHUTZ-Gerät wird zur individuellen Überwachung seines Stromkreises usw. mit einem HAUPTSCHUTZ-Relais verbunden. Im Sonderfall: Sammelstörmeldung Hierfür werden bis zu 2 TYTAN-HAUPTSCHUTZ-Geräte hintereinander geschaltet mit einem HAUPTSCHUTZ-Relais verbunden. A B Connections: All connections of MAIN PROTECTION components will be done easily and quick by means of plugged RJ0 cables. Verbindungen: Alle Verknüpfungen der HAUPTSCHUTZ-Komponenten werden mit RJ0-Steckerleitungen einfach und schnell hergestellt.

2 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Features / Features TYTAN MAIN PROTECTION is a super short circuit protection. Der TYTAN HAUPTSCHUTZ ist der Superkurzschlussschutz. The fuse-link blows rapidly within 0,ms. In comparison to electromechanical switchgear this operation is at least 40 times faster. The very high destructive acting short circuit energy will be absorbed while melting within the quartz sand. This increases the life-cycle of the connected devices e.g. contactor, motor protector and motor. At the same time the monitoring electronic will be activated and the switch off command can interact the control circuit. Der Sicherungseinsatz schaltet rasant, innerhalb 0,ms, ab. Das ist, im Vergleich zu elektromechanischen Verfahren, um mindestens Faktor 40 schneller. Die sehr hohe gefahrbringende Kurzschlussenergie wird durch das Schmelzen des Quarzsandes absorbiert. Dadurch erhöht sich die Lebensdauer der angeschlossenen Geräte wie z.b. Schütz, Motorschutz und Motor. Gleichzeitig wird die elektronische Überwachung aktiviert und der Ausschaltbefehl gegeben und es kann in den Steuerstromkreis eingegriffen werden. TYTAN MAIN PROTECTION is a two-phase running protection. Der TYTAN HAUPTSCHUTZ ist Zweiphasenlaufschutz. At a short circuit between phase and neutral (N) or protected earth (PE) it comes to a dangerous two-phase running. If the motor is running in a partial load operation the bi-metal of the thermal motor protector relay is inefficient. TYTAN MAIN PROTECTION acts without delay by means of an immediate switch off command. Bei einem Kurzschluss zwischen einem Außenleiter und N oder PE kommt es zum gefahrbringenden Zweiphasenlauf. Befindet der Motor sich dann im Teillastbetrieb, so ist das Bimetall des Motorschutz-Relais wirkungslos. Der Hauptschutz reagiert unverzögert durch sofortigen Ausschaltbefehl. TYTAN MAIN PROTECTION is an overheated protection. Der TYTAN HAUPTSCHUTZ ist Überhitzungsschutz. The Switch disconnector fuse is monitored against dangerous overheat. Der Sicherungslasttrennschalter wird gegen Überhitzung überwacht. 34

3 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Features / Features Function / Funktion L L2 L3 K2S 2 4 K2S 2 K2S K2S 3 F 2 4 C 2 F KM F TYTAN HR Main protection relay Hauptschutzrelais 0 I 2 3 KM M M 3 ~ KM Motor Motor ON EIN Overload Überlastet Short-circuit Kurzschluss Overheat Überhitzt This diagram shows: The security hole is closed. In addition service can be organised more sufficient; immediate help can be provided because of detailed fault indication. At lightning speed the decision is done if a skilled person is necessary or if the layperson is sufficient enough to restart. All measures increase the operation safety and decrease the costs. Das obige Grundschaltbild zeigt: Die Sicherheitslücke ist geschlossen. Zusätzlich kann der Service besser organisiert werden; es kann für eine sofortige Abhilfe gesorgt werden, weil die Fehler einzeln benannt werden. Es wird blitzschnell entschieden, ob vor Ort der Fachmann notwendig ist oder ob das laienhafte Bedienungspersonal ausreichend ist. Alle Maßnahmen heben die Betriebssicherheit und senken die Kosten. 35

4 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Range / Produktpalette TYTAN HR HR HR2 TYTAN RH Description / Beschreibung TYTAN-Main protection relay (Supply voltage 24VDC) with LED s for INDIVIDUAL MONITORING - For monitoring of..2 Switch disconnector. TYTAN-Hauptschutzrelais (Versorgungsspannung 24VDC) mit LEDs für EINZELAUSWERTUNG - Für die Überwachung von Lasttrennschalter. HR RELAY (Change over contact) RELAIS (Wechsler) x ON / x EIN x FUSE MONITORING / x SICHERUNG x TEMPERATURE MONITORING x TEMPERATUR Ref. Artikel-Nr. COLLECTED FAULT MONITORING For monitoring of..2 Switch disconnector SAMMELSTÖRAUSWERTUNG - Für die Überwachung von..2 Lasttrennschalter HR2 RELAY (Change over contact) RELAIS (Wechsler) x FUSE MONITORING / x SICHERUNG x TEMPERATURE MONITORING x TEMPERATUR pcs/pack VPE kg/pc kg/stk , ,05 HR3 x FAULT MONITORING ,04 x FEHLER TYTAN HC Connection cable RJ0 Max. Line length until the farthest switch disconnector 2m TYTAN HC Verbindungskabel RJ0 Max. Leitungslänge bis zum entferntesten Lasttrennschalter 2m 5cm ,003 25cm ,004 50cm ,008 75cm ,02 00cm ,05 TYTAN-Main protection Switch disonnector fuse with integrated monitoring electronic and LED s for 60mm Bus bar system TYTAN-Hauptschutz Lasttrennschalter mit Sicherungen mit integrierter Überwachungselektronik und LEDs für das 60mm Sammelschienensystem D0 (2-63A) 400 VAC; 0x38mm (2-32A) 3 poles / 3-polig ,42 3 poles + N / 3-polig + N ,52 0x38mm (2-32A) 500 VAC 3 poles / 3-polig ,42 3 poles + N / 3-polig + N ,52 Plug-Reduction spring for D0 and 0x38mm fuse-links Stecker-Reduzierfeder für D0 und 0x38mm Sicherungen /288 0,0 36

5 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Range / Produktpalette TYTAN HR MAIN PROTECTION-Relay INDIVIDUAL MONITORING HAUPTSCHUTZ-Relais EINZELAUSWERTUNG HR Optical indication / Optische Anzeigen TYTAN HR Switch Disconnector ON / Lasttrennschalter EIN Main Protection FAULT / Hauptschutz STÖRUNG Fuse-link OK / blown / Sicherung OK / ausgelöst Thermal OK / overloaded / Thermisch OK / überhitzt LED green / grün yellow / gelb green / red / grün / rot green / yellow / grün / gelb TEST / RESET Push button Taste OPERATION / BETRIEB In connection with 2 switch disconnector In Verbindung mit 2 Lasttrennschalter TYTAN RH oder TYTAN TH TYTAN HR2 MAIN PROTECTION-Relay COLLECTED FAULT MONITORING HAUPTSCHUTZ-Relais SAMMELSTÖRMELDUNG HR2 Optical indication / Optische Anzeigen TYTAN HR2 Main Protection OK / FAULT / Hauptschutz OK / STÖRUNG Fuse-link OK / blown / Sicherung OK / ausgelöst Thermal OK / overloaded / Thermisch OK / überhitzt LED green / yellow grün / gelb green / red / grün / rot green / yellow / grün / gelb TEST / RESET Push button Taste OPERATION / BETRIEB In connection with 2 switch disconnector In Verbindung mit 2 Lasttrennschalter TYTAN RH oder TYTAN TH TYTAN HR3 MAIN PROTECTION-Relay COLLECTED FAULT MONITORING HAUPTSCHUTZ-Relais SAMMELSTÖRMELDUNG HR3 Optical indication / Optische Anzeigen TYTAN HR3 Main Protection OK / FAULT / Hauptschutz OK / STÖRUNG Fuse-link OK / blown / Sicherung OK / ausgelöst Thermal OK / overloaded / Thermisch OK / überhitzt LED green / yellow grün / gelb green / red / grün / rot green / yellow / grün / gelb TEST / RESET Push button Taste OPERATION / BETRIEB In connection with 2 switch disconnector In Verbindung mit 2 Lasttrennschalter TYTAN RH oder TYTAN TH 37

6 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Range / Produktpalette TYTAN HR, TYTAN HR2, TYTAN HR3 Type range / Typenspektrum INDIVIDUAL MONITORING / EINZELAUSWERTUNG Description Beschreibung Type Typ Ref. Artikel-Nr. Relays / Relais TYTAN HR CO -2-4 CO CO Switch Disconnector ON Lasttrennschalter EIN Fuse-link lown Sicherung ausgelöst Switch Disconnector too hot Lasttrennschalter überhitzt COLLECTED FAULT MONITORING / SAMMELSTÖRMELDUNG Description Beschreibung Type Typ Ref. Artikel-Nr. Relays / Relais TYTAN HR CO CO CO Fuse-link lown Sicherung ausgelöst Switch Disconnector too hot Lasttrennschalter überhitzt Switch Disconnector FAULT Lasttrennschalter FEHLER TYTAN HR Accessories / Zubehör Description Beschreibung Connection cable / Verbindungskabel RJ 0 Length Länge 5 cm Type Typ Ref. Artikel-Nr cm cm TYTAN HC cm cm Dimensions / Abmessungen 38

7 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten TYTAN HR, TYTAN HR2, TYTAN HR3 ELECTRICAL PROPERTIES / ELEKTRISCH EIGENSCHAFTEN Standards DIN EN 6000 (EMC-noise immunity) (EMV-Störsicherheit) IEC/EN , IEC/EN EN MONITORING ELECTRONIC CIRCUIT / ÜBERWACHUNGSELEKTRONIK Rated voltage / Bemessungsspannung 24 V CD TYTAN HR P Power consumption n,5 W TYTAN HR2 0,95 W Leistungsaufnahme TYTAN HR3 0,75 W RELAY CONTACTS / RELAISKONTAKTE TYTAN HR TYTAN HR2 TYTAN HR3 Rated operational voltage / current Bemessungsbetriebs-spannung / -strom Minimum rated operational voltage / current Mindestbemessungsbetriebs-spannung / -strom Dielectric strength Durchschlagsfestigkeit Rated impulse withstand voltage Bemessungsstoßspannungsfestigkeit Overvoltage category Überspannungskatekorie GENERAL / ALLGEMEIN Comparative tracking index Kriechstromfestigkeit Vibration resistance (function) Vibrationsfestigkeit (Funktion) Shock resistance (destruction) Schockfestigkeit (Zerstörung) 3 CO contacts / 3 Wechsler 2 CO contacts / 2 Wechsler CO contacts / Wechsler U e / l e 250V / 5Aµ AC 30V / 5A DC 300V / 0,25A DC U e / l e 00mV / 0mA kv Coil-contact circuit / Spule-Kontakte Open contact circuit / Offener Kontakte U imp CTI 600 NO / NC contact Schließer / Öffner Kontakt 4 kv rms / kv efs kv rms / kv efs 4 kv III 5 / 5G m/s 2 00G m/s 2 39

8 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten TYTAN HR, TYTAN HR2, TYTAN HR3 Electrical properties / Elektrisch eigenschaften RELAY CONTACTS / RELAISKONTAKTE Electrical Endurance Elektrische Lebensdauer Cycles Zyklen 250 VAC Resistive load Ohmsche Last AgNi90/0 Max. DC Load breaking capacity Max. DC Lastschaltvermögen Switching current Schalt-Strom [A] DC Voltage DC Spannung [VDC] Resistive load Ohmsche Last Circuit diagram / Schaltbilder DC Current DC Strom [A] HR HR2 HR3 2 4 C 2 C C

9 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten TYTAN HR, TYTAN HR2, TYTAN HR3 MECHANICAL PROPERTIES / MECHANISCH EIGENSCHAFTEN Weight / Gewicht HR 63 g HR2 53 g HR3 43 g Terminal / Klemmen Lift Terminal / Liftklemmen Screw Schraube Pozidriv PZ Cross section Flexible x 2,55 mm 2 Anschlussquerschnitt Flexibel AWG 4 Flexible x 4 mm 2 Flexibel AWG 2 Flexible x,5 mm 2 Flexibel AWG 6 Tightening torque Anzugsdrehmoment M n 0,5 Nm Degree of protection (behind front plate) Schutzart (hinter Frontplatte) Touch protection Berührungsschutz Temperature range Berührungsschutz Flame class Brandklasse Glow-wire test Glühdrahtprüfung Pollution degree Verschmutzungsgrad Plastic Kunststoff IP 20 / IP 40 finger and hand touch safe BGV A3 finger und handrückensicher ÖVE-EN 6 Ambient / Umgebung -25 bis +60 ºC Storage / Lagerung -40 bis +60 ºC according to UL94 V0 nach UL C Halogen-, silicone-, and phosphor free halogen-, phosphor-, silikonfrei 3 Connection cable to Switch disconnector / Verbindungskabel zum Lasttrennschalter RJ 0 Mounting / Montage Tool less onto Hat rail 35mm / Werkzeuglos auf Hut-Schiene 35mm 35 Cut-out for front plate / Frontplattenausschnitt [mm] For Hat rail according to IEC/EN 6075 Für Hut-Schienen nach IEC/EN 6075 [mm] 45 n 35 n x 7, Dimensions W x H x D / Abmessungen B x H x T 7,8 x 92,5 x 8,8 mm 4

10 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Range / Produktpalette MAIN PROTECTION Switch disconnector fuse with integrated monitoring electronic circuit HAUPTSCHUTZ Lasttrennschalter mit Sicherungen mit integrierter Überwachungselektronik Optical indication / Optische Anzeigen Main Protection in operation / Hauptschutz betriebsbereit Thermal overloaded / Thermisch überhitzt Fuse-link blown / Sicherung ausgelöst LED green / grün yellow / gelb red / rot Mechanical indication / Mechanische Anzeige Contact position indication / Kontaktstellungsanzeige red / green / rot / grün Lockable in ON / OFF - position / Versperrbar in EIN / AUS - Positon Sealable in ON / OFF - position / Plombierbar in EIN / AUS - Position OPERATION / BETRIEB In connection with a main protection relay In Verbindung mit einem Hauptschutzrelais Dimensions / Abmessungen Dimensions W x H x D Abmessungen B x H x T 3P 3P+N 35,8 x 244 x 02 mm 36 x 280 x 03 mm 3P 3P+N 42

11 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Range / Produktpalette TYTAN RH Type range / Typenspektrum Description Beschreibung Rated operational voltage / Bemessungsbetriebsspannung 400 VAC 50Hz Rated operational current / Bemessungsbetriebsstrom D0 2-63A 0x A Ref. Artikel Nr. 3 poles / 3 polig poles + N / 3 polig + N Rated operational voltage / Bemessungsbetriebsspannung 500 VAC 50Hz Rated operational current / Bemessungsbetriebsstrom 0x A 3 poles / 3 polig poles + N / 3 polig + N Accessories / Zubehör Description Beschreibung Ref. Artikel Nr. Adapter spring / Stecker-Reduzierfeder D0, 0x

12 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten TYTAN RH ELECTRICAL PROPERTIES / ELEKTRISCH EIGENSCHAFTEN Standards Poles / Polzahlen Rated operational voltage Bemessungsbetriebsspannung Rated operational current Bemessungsbetriebsstrom Rated uninterrupted current Bemessungsdauerstrom Rated conditional short-circuit current Bedingter Bemessungskurzschlussstrom Rated short-circuit making capacity Bemessungskurzschlusseinschaltvermögen Rated short-circuit making capacity Bemessungsstoßspannungsfestigkeit Overvoltage category Überspannungskatekorie Comparative tracking index Kriechstromfestigkeit Power loss per current path without fuse-link Verlustleistung pro Strombahn ohne Sicherung Max. permissible power loss of fuse-links Max. zulässige Verlustleistung der Sicherung IEC/EN , IEC/EN IEC/EN , IEC/EN IEC/EN DIN VDE 0636, DIN P, 3P+N U e D0 (0x38) 400 VAC D0-Spezial 440 VAC 0x VAC l e D0 63 A 0x38 32 A l u D0 63 A 0x38 32 A 50 ka rms / kv eff l cm U imp CTI 600 at l e bei l e P n per Pol per Pole 50 ka rms / kv eff 6 kv IV,5 W 5,5 W Circuit diagram / Schaltbilder 3P 3P+N C C 44 MONITORING ELECRONIC CIRCUIT / ÜBERWACHUNGSELEKTRONIK Standards DIN EN 6000 (EMC-noise immunity) (EMV-Störsicherheit) IEC/EN , IEC/EN Power consumption P n Operation / Betrieb 0,4 W Leistungsaufnahme Fault / Störung,55 W

13 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten TYTAN RH MECHANICAL PROPERTIES / MECHANISCH EIGENSCHAFTEN Weight / Gewicht 3P 424,5 g 3P+N 520 g Terminal / Klemmen Lift Terminal Liftklemmen stainless steel antimagnetic antimagnetischer Edelstahl Screw Pozidriv PZ2 Schraube Cross section,5-35 mm 2 Anschlussquerschnitt AWG 2-6 Tightening torque M n 4 Nm Anzugsdrehmoment Degree of protection (behind front plate) IP 20 / IP 40 Schutzart (hinter Frontplatte) Touch protection Berührungsschutz finger and hand touch safe finger und handrückensicher BGV A3 ÖVE- EN 6 Temperature range Ambient / Umgebung -25 bis +60 ºC Berührungsschutz Storage / Lagerung Flame class according to UL94 V0 Brandklasse nach UL 94 Glow-wire test Glühdrahtprüfung 960 C Climatic resistance IEC Moist heat / Feuchte Hitze Constant / Konstant Klimafestigkeit IEC Cyclical / Zyklisch Pollution degree 3 Verschmutzungsgrad Plastic Kunststoff Halogen-, silicone-, and phosphor free halogen-, phosphor-, silikonfrei Connection cable to Main protection relay / Verbindungskabel zum Hauptschutzrelais RJ 0 Mounting / Montage Tool less onto Bus bar system 60mm Werkzeuglos auf 60mm Sammelschienensystem Cut-out for front plate / Frontplattenausschnitt [mm] For Cu-bars Für Cu-Schienen [mm] n 95 n x x

14 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten EXAMPLE LOAD CIRCUIT- INDIVIDUAL MONITORING BEISPIEL VERBRAUCHERSTROMKREIS- EINZELAUSWERTUNG L L2 L3 N Realisation of a selective switch off of load circuits will be enabled by using a main protection relay. It allows an active intervention in the electrical control system. E.g. Start-up of a reserve pump. Selektives Abschalten von Anlagenteilen wird durch das Hauptschutzrelais erst realisierbar. Es ermöglicht den aktiven Eingriff in die Steuerung der elektrischen Anlage z.b. Reserve-Pumpe anfahren. Main protection relay Hauptschutzrelais KS Main protection relay Hauptschutzrelais K2S F 2 4 F2 2 4 C C 2 C C 2 Q 3 Q2 3 K TYTAN HR K2 TYTAN HR Z E 3 2 Z2 E 3 2 Application examples: - Pump stations Public water supply Clarification plants - Railway properties Turnout heating, Lighting, Adjusting drives - Air ports - Traffic engineering Street lighting, Traffic signs - Tunnel facilities - Chemical industry Pipe heating, Pumps, Valves -Tank farms - Refrigerating plants - Hospitals Anwendungsgebiete: - Pumpstationen Wasserversorgung Kläranlagen - Bahnanlagen Weichenheizung, Beleuchtung, Stellantriebe - Flughäfen - Verkehrstechnik Straßenbeleuchtung Verkehrszeichen - Tunnelbauten - Chemie Rohrheizungen, Pumpen, Ventile - Tankanlagen - Gefrieranlagen - Krankenhäuser 46

15 60mm Busbar system / 60mm Sammelschienensystem TYTAN HR/RH Main protection / TYTAN HR/RH - Hauptschutz Technical data / Technische Daten EXAMPLE LOAD CIRCUIT- COLLECTED FAULT MONITORING BEISPIEL VERBRAUCHERSTROMKREIS- SAMMELSTÖRAUSWERTUNG L L2 L3 N At a collected fault monitoring system the fault is monitored by the main protection relay, but you cannot allocate it for control commands. A selective switch off of the effected load circuit is impossible. The skilled person can localise the effected switch disconnector immediately by means of flashing LED s. That means less standstill times and furthermore a cost reduction. F Q C Bei der Sammelstörmeldung wird zwar die Fehlerursache durch das Hauptschutzrelais angezeigt, man kann den Fehler aber nicht steuerungstechnisch zuordnen. Ein selektives automatisches Abschalten des betroffenen Anlagenteiles ist somit nicht möglich. Die Fachkraft kann den Fehler, durch die blinkende LED am jeweiligen Lasttrennschalter, sofort lokalisieren. Das bedeutet geringere Stillstandzeiten und damit eine Kostensenkung. Main protection relay Hauptschutzrelais KS TYTAN HR2 2 4 F2 F3 F4 C 2 C C C 3 Z E Z2 E Z3 E KS 2 K KS 3 K2 K 2 4 K SERVICE BY A SKILLED PERSON SERVICE DURCH FACHKRAFT 2 4 Application examples: - Industrial plants - Energy distribution of Schools Universities Municipal offices Post offices Health fund offices Museum Anwendungsgebiete: - Industrieanlagen - Energieverteilung Schulen Universitäten Gemeindeämter Postämter Krankenkassen Museen Kurzschluss Short-circuit Überhitzt Overheat 47

Bedienungsanleitung / Manual

Bedienungsanleitung / Manual HAUPTSCHUTZ-Lasttrennschalter mit Sicherungen mit integrierter Überwachungselektronik MAIN PROTECTION-Switch disconnector fuse with integrated monitoring electronic circuit FOTO INFO Optische Anzeigen

Mehr

TYTAN TH1. Optische Anzeigen - Hauptschutz betriebsbereit grün - Thermisch überhitzt gelb - Sicherung ausgelöst rot

TYTAN TH1. Optische Anzeigen - Hauptschutz betriebsbereit grün - Thermisch überhitzt gelb - Sicherung ausgelöst rot HAUPTSCHUTZ-Lasttrennschalter mit Sicherungen mit integrierter Überwachungselektronik MAIN PROTECTION-Switch disconnector fuse with integrated monitoring electronic circuit FOTO INFO Optische Anzeigen

Mehr

EINZELAUSWERTUNG INDIVIDUAL MONITORING

EINZELAUSWERTUNG INDIVIDUAL MONITORING TYTAN HR11 HAUPTSCHUTZ-Relais MAIN PROTECTION-Relay FOTO EINZELAUSWERTUNG INDIVIDUAL MONITORING INFO Optische Anzeigen Optical indication TYTAN HR11 LED - Lasttrennschalter EIN / grün / Hauptschutz STÖRUNG

Mehr

Ausführungen (Reduzierfeder für D01 werden lose mitgeliefert) kg/stück VE Artikel-Nr.

Ausführungen (Reduzierfeder für D01 werden lose mitgeliefert) kg/stück VE Artikel-Nr. WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN RH4 Reiter - Lasttrennschalter

Mehr

Ausführungen kg/stück VE Artikel Nr.

Ausführungen kg/stück VE Artikel Nr. WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 D-95448 Bayreuth Telefon +49 (0) 921 1512678-0 Telefax +49 (0) 921 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN II Hauptschutz

Mehr

DC Unter-/ Überspannungsmess-Relais

DC Unter-/ Überspannungsmess-Relais WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de DC Unter-/ Überspannungsmess-Relais

Mehr

Datenblatt / Data sheet

Datenblatt / Data sheet Seite/Page 1/5 Abbildungen / Illustration Maßzeichnung / Dimensions Produktbeschreibung Product specification Kompaktes, steckbares Relais für den industriellen Einsatz. Compact, pluggable relay for industrial

Mehr

Unterspannungsmess-Relais

Unterspannungsmess-Relais WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de Unterspannungsmess-Relais

Mehr

Unterspannungsmess-Relais mit Drehfelderkennung

Unterspannungsmess-Relais mit Drehfelderkennung WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de Unterspannungsmess-Relais

Mehr

Unter-/ Überspannungsmess-Relais mit Drehfelderkennung

Unter-/ Überspannungsmess-Relais mit Drehfelderkennung WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de Unter-/ Überspannungsmess-Relais

Mehr

Sicherheits - Lasttrennschalter für D0 - und Zylindersicherungen 10 x 38 mm

Sicherheits - Lasttrennschalter für D0 - und Zylindersicherungen 10 x 38 mm WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN T Sicherheits - Lasttrennschalter

Mehr

Ausführungen (Reduzierfeder für D01 werden lose mitgeliefert) kg/stück VE Artikel-Nr.

Ausführungen (Reduzierfeder für D01 werden lose mitgeliefert) kg/stück VE Artikel-Nr. WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN R Reiter - Lasttrennschalter

Mehr

TYTAN TH1. Ausführungen (Reduzierfeder für D01 werden lose mitgeliefert) kg/stück VE Artikel-Nr.

TYTAN TH1. Ausführungen (Reduzierfeder für D01 werden lose mitgeliefert) kg/stück VE Artikel-Nr. WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN TH1 Lasttrennschalter

Mehr

TYTAN II Hauptschutz auf Geräte-Adapter

TYTAN II Hauptschutz auf Geräte-Adapter WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN II Hauptschutz auf

Mehr

Protection modular systems. DIN-Hutschienen- und 60mm Sammelschienenkomponenten. www.pronutec.com

Protection modular systems. DIN-Hutschienen- und 60mm Sammelschienenkomponenten. www.pronutec.com Protection modular systems DIN-Hutschienen- und 60mm Sammelschienenkomponenten www.pronutec.com Protection modular systems for DIN rail and 60mm busbar distance DIN-Hutschienen- und 60mm Sammelschienenkomponenten

Mehr

PI-T001/c. Developed especially for short-circuit protection in Telekom DC-power supply requirements.

PI-T001/c. Developed especially for short-circuit protection in Telekom DC-power supply requirements. NH-Sicherungslasttrennschalter und NH-Sicherungen für die Stromversorgung von Telekommunikationseinrichtungen LV HRC fuse switch-disconnectors and LV HRC fuses for telecom power supply Speziell für den

Mehr

ABB i-bus EIB. EIB Power Supply Units

ABB i-bus EIB. EIB Power Supply Units ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!

Mehr

Ausführungen kg/stück VE Artikel Nr.

Ausführungen kg/stück VE Artikel Nr. WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 95448 Bayreuth Telefon (0921) 1512678-0 Telefax (0921) 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de TYTAN II Hauptschutz D0-Sicherungslasttrennschalter

Mehr

S202M-C0,5. Miniature Circuit Breaker - S200M - 2P - C ampere. General Information. Ordering. Popular Downloads. Dimensions.

S202M-C0,5. Miniature Circuit Breaker - S200M - 2P - C ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200M - 2P - C - 0.5 ampere General Information Extended Product Type Product ID S202M-C0,5 2CDS272001R0984 EAN 4016779550208 Catalog Description Long Description Miniature

Mehr

Protection modular systems for DIN rail and 60mm busbar system DIN-Hutschienen-und 60mm Sammelschienenkomponenten

Protection modular systems for DIN rail and 60mm busbar system DIN-Hutschienen-und 60mm Sammelschienenkomponenten Protection modular systems for DIN rail and 60mm busbar system DIN-Hutschienen-und 60mm Sammelschienenkomponenten 2 Contents / Inhaltsverzeichnis Page Seite 1 2 60mm Classic Busbar System / 60mm Classic

Mehr

DATENBLATT / DATA SHEET

DATENBLATT / DATA SHEET Zähleranschlussklemmen und Zubehör Meter connection terminal and accessories FOTO INFO Für Elektrizitätszähler nach DIN 43857 - Mit Anschlussraumabdeckung - Mit Standard Zähler-Klemmendeckel abdeckbar

Mehr

S201-C6. Miniature Circuit Breaker - S200-1P - C - 6 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-C6. Miniature Circuit Breaker - S200-1P - C - 6 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - C - 6 ampere General Information Extended Product Type Product ID S201-C6 2CDS251001R0064 EAN 4016779464000 Catalog Description Long Description Miniature Circuit

Mehr

S202M-C10. Miniature Circuit Breaker - S200M - 2P - C - 10 ampere. General Information. Ordering. Popular Downloads. Dimensions. Technical S202M-C10

S202M-C10. Miniature Circuit Breaker - S200M - 2P - C - 10 ampere. General Information. Ordering. Popular Downloads. Dimensions. Technical S202M-C10 ABB Miniature Circuit Breaker - S200M - 2P - C - 10 ampere General Information Extended Product Type Product ID S202M-C10 2CDS272001R0104 EAN 4016779550284 Catalog Description Long Description Miniature

Mehr

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs 2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with

Mehr

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert. Beschreibung Description: Verteiler nach Vandalengeschützte Einzeltaster für den Einbau in Frontplatten und Gehäuse mit den Einbaumassen 18mm und 22 mm. Bei diesen Ausführungen bestehen sowohl Betätiger

Mehr

2. 35mm DIN rail protection system 35mm Hutschienen System

2. 35mm DIN rail protection system 35mm Hutschienen System . 35mm DIN rail protection system 35mm Hutschienen System D0 Fuse switch disconnector TYTAN II D0 Sicherungslasttrennschalter TYTAN II Reliable with flashing indicator Plug-in technique without screw caps

Mehr

Overview thermostat/ temperature controller

Overview thermostat/ temperature controller Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:

Mehr

Inductive proximity switch

Inductive proximity switch 3RG4070-0CD00-PF NO and NC / Schließer und Öffner 3RG4070-3CD00-PF NO and NC / Schließer und Offner 3RG4070-7CD0-PF NO and NC Schließer und Öffner 3RG4070-7CD0-PF NO and NC Schließer und Öffner Cable /

Mehr

Motorschutz-Leistungsschalter MPW12 und MPW18 - Technische Daten

Motorschutz-Leistungsschalter MPW12 und MPW18 - Technische Daten Motorschutz-Leistungsschalter MPW12 und MPW18 - Technische Daten Bestimmungen Typ MPW12 MPW12i MPW18 MPW18i IEC/EN 60947, DIN VDE 0660, UL/CS, BV, EC Bemessungsisolationsspannung Ui nach IEC 60947, DIN

Mehr

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1)

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1) Kundenspezifische, unterbaufähige Netzdrosseln für Siemens-Umrichter der Serien SINAMICS GC und G mit Leistungsmodul PM240-2 (Standard-Variante). Die Drosseln sind seitlich ohne Abstand anreihbar. Line

Mehr

NHS02 NH-Sicherungslastschaltleiste Fuchs-185 Typ: FSL00..

NHS02 NH-Sicherungslastschaltleiste Fuchs-185 Typ: FSL00.. Technische Daten FSL00 NHS02 NH-Sicherungslastschaltleiste Fuchs-185 Typ: FSL00 Elektrische Kenngrössen electrical characteristics Nach Norm / according to standard DIN EN 60947- Für NH-Sicherungen nach

Mehr

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm Ultrakompakt 87 x 54 x 26 mm + Ultra compact 87 x 54 x 26 mm + + Bis zu 57 W oder 2 x 27 W Up to 57 W or 2 x 27 W Einzigartig klein Unique small size Der Klassiker The classic Darf es ein bisschen mehr

Mehr

SCHMELZSICHERUNGS-, SAMMELSCHIENENSYSTEME

SCHMELZSICHERUNGS-, SAMMELSCHIENENSYSTEME W SICHERUNGSTRENNSCHALTER FÜR ZYLINDRISCHE SICHERUNGEN IS506223 IS506101 W SCHRACK-INFO Die D-Diazed oder D0-Neozed-Sicherungen werden vor allem im deutschsprachigen Raum eingesetzt. In anderen Ländern

Mehr

D0-Sicherungseinsätze und -Sicherungssockel D0 fuse-links and fuse-bases

D0-Sicherungseinsätze und -Sicherungssockel D0 fuse-links and fuse-bases D0-Sicherungseinsätze und -Sicherungssockel D0 fuse-links and fuse-bases Vorteile, die überzeugen / Convincing advantages Bewährte Technik Anwendungen und Hausinstallationen schützten Aufbau und Unverwechselbarkeit

Mehr

Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen

Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen 15 00 V! Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen Pronutec offers his Fuse bases for DC installations up to 1500 V: the 1P NH type Fuse bases with

Mehr

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3

Mehr

6GR1811-7BD05 PXO840 LV70 Schaltausgang + Anzeige, Stecker M8, 4-polig Switching output + display, M8 connector, 4-pole

6GR1811-7BD05 PXO840 LV70 Schaltausgang + Anzeige, Stecker M8, 4-polig Switching output + display, M8 connector, 4-pole -0BD05 Schaltausgang, Kabel, 4-polig Switching output, cable, 4 pole -7BD05 Schaltausgang, Stecker M8, 4-polig Switching output, M8 connector, 4 pole -7BD05 Schaltausgang + Anzeige, Stecker M8, 4-polig

Mehr

General Information. Ordering. Popular Downloads. Dimensions. Technical

General Information. Ordering. Popular Downloads. Dimensions. Technical S202M-C16 Products Low Voltage Products and Systems Modular DIN Rail Products Miniature Circuit Breakers MCBs General Information Extended Product Type: S202M-C16 Product ID: 2CDS272001R0164 EAN: 4016779550307

Mehr

Position switch // ES 95 / EM 95

Position switch // ES 95 / EM 95 Features/Options Thermoplastic enclosure Horizontally slotted mounting holes Double insulated X ES 95: Slow action A, change-over contact, change-over contact with overlapping, 2 NC contacts or 2 NO contacts

Mehr

Taster LDT, Schalter LDS Switches in momentary action LDT, and latching action LDS

Taster LDT, Schalter LDS Switches in momentary action LDT, and latching action LDS Taster LDT, LDS Switches in momentary action LDT, and latching action LDS Aufbau Construction Frontplattenmontage Frontpanel mounting Abmessungen Dimensions Anschlussbelegung Wiring diagram Schaltsymbol

Mehr

Dreiphasige Energie-und Leistungszähler Power and Energy Meter

Dreiphasige Energie-und Leistungszähler Power and Energy Meter Dreiphasige Energie-und Leistungszähler Power and Energy Meter Bedienungsanleitung Operation Instructions Direktanschluss 10(63)A 7KT1 162 Wandleranschluß-Zähler 5(6)A 7KT1 165 Direct-connection 10(63)A

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich

Mehr

2. 35mm DIN rail protection system 35mm Hutschienen System. D01 Fuse switch-disconnector TYTAN I D01 Sicherungslasttrennschalter TYTAN I

2. 35mm DIN rail protection system 35mm Hutschienen System. D01 Fuse switch-disconnector TYTAN I D01 Sicherungslasttrennschalter TYTAN I . 35mm DIN rail protection system 35mm Hutschienen System D01 Fuse switch-disconnector TYTAN I D01 Sicherungslasttrennschalter TYTAN I PROTECTI MODULAR SYSTEMS / DIN-HUTSCHIENEN- UND 60MM SAMMELSCHIENENKOMPENTEN

Mehr

Automation components Bauteile für Automatisierung MINIATURE POWER RELAYS MINIATUR-INDUSTRIERELAIS TRP 312, 314, 322, 324

Automation components Bauteile für Automatisierung MINIATURE POWER RELAYS MINIATUR-INDUSTRIERELAIS TRP 312, 314, 322, 324 Automation components Bauteile für Automatisierung MINIATURE POWER RELAYS MINIATUR-INDUSTRIERELAIS TRP 312, 314, 322, 324 TRP 312, 314, 322, 324 New generation of miniature industry relays TRP 3 Compact

Mehr

IDG. Drehzahlsensor / Speed Sensor

IDG. Drehzahlsensor / Speed Sensor Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W Kraftvoll bis 200 W + Powerful up to 200 W + + Kleine Bauform Small size Betriebsanzeige über LED und Meldekontakt Status LED and signal contact Zuverlässig entkeimen. Reliable desinfection. Linear V UV

Mehr

Optimierte Leistungsabgabe Ermöglicht Einsatz in Standard- Schaltgeräten

Optimierte Leistungsabgabe Ermöglicht Einsatz in Standard- Schaltgeräten Sicherungseinsätze Betriebsklasse gs für den kombinierten Halbleiter- und Leitungsschutz Fuse-links utilization category gs for combined semiconductor and line protection Vorteile, die überzeugen / Convincing

Mehr

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters Application and performance characteristics Typically used to comply with EMC emission standards Reduce conducted emissions over the frequency range 150 khz to 30 MHz Suitable for Industrial, Railway,

Mehr

VARIOFACE Systemverkabelung

VARIOFACE Systemverkabelung VARIOFACE Systemverkabelung Systemkabel und Übergabemodule für Yokogawa ProSafe-RS INTERFACE Phoenix Contact Dezember 12 Beinhaltet Crossliste......2 Übergabemodule.. 3 VARIOFACE System Cabling System

Mehr

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012 Heaters for Enclosures SM 10-45 - Selbstregelnde PTC-Heizungen mit 10-45 W - Optimiertes Profil mit verbesserter Heizleistung und geringerer Oberflächentemperatur - Montage und Anschluss ohne Werkzeug

Mehr

Ex emergency pull-wire switches // Ex ZS 75 S

Ex emergency pull-wire switches // Ex ZS 75 S Features/Options Ex zone 1 and 21 Metal enclosure 2 or 4 contacts Wire length up to 2 x 100 m Release by push button (VD) Available without unlocking mechanism (per EN 60947-5-1) Wire pull and breakage

Mehr

Inductive proximity switch

Inductive proximity switch RG44-6AD00-PF RG44-6AD04-PF RG44-AD00-PF Size / Bauform Mounting / Einbau screw terminals (terminal compartment) Schraubklemmen (Anschlußraum) screw terminals (terminal compartment) Schraubklemmen (Anschlußraum)

Mehr

TECHNISCHE DATEN Hochleistungsrelais TECHNICAL DATA High Power Relay

TECHNISCHE DATEN Hochleistungsrelais TECHNICAL DATA High Power Relay TECHNISCHE DATEN Hochleistungsrelais TECHNICAL DATA Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3 Serie 911 Hochleistungsrelais

Mehr

Betriebsanleitung/ Operating instructions. EGA/PC-Interface-2 EGA/PC-Interface Anschlussbox 4-fach

Betriebsanleitung/ Operating instructions. EGA/PC-Interface-2 EGA/PC-Interface Anschlussbox 4-fach Betriebsanleitung/ Operating instructions EGA/PC-Interface Anschlussbox 4-fach EGA/PC-Interface Connectionbox fourfold Zielgruppe: Elektrofachkräfte Target group: Skilled electricians 400 71 860 070 Inhaltsverzeichnis

Mehr

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

A P max. 16bar P R max. 64bar R P max. 16bar

A P max. 16bar P R max. 64bar R P max. 16bar direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

DILM12-10(230V50HZ,240V60HZ)

DILM12-10(230V50HZ,240V60HZ) 11.10.2010 1 Leist.-schuetz, 5,5kW/400V, AC-betaetigt Typ DILM12-10(230V50HZ,240V60HZ) Best.-Nr. 276830 Lieferprogramm Anschlusstechnik Schraubklemmen Betätigungsspannung 230 V 50 Hz, 240 V 60 Hz Stromart

Mehr

Control shut-off butterfly valves DN 50 DN 400 PN

Control shut-off butterfly valves DN 50 DN 400 PN Features Applications include HEVAC and drinking water systems, sanitary and industrial plants for control or shut-off of water and steam -10...+110 C Leakage rate: tight sealing Control and shut-off butterfly

Mehr

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

WIC1-TU Abfrageeinheit für das WIC1 Monitoring unit for WIC1 relays

WIC1-TU Abfrageeinheit für das WIC1 Monitoring unit for WIC1 relays WIC1-TU Abfrageeinheit für das WIC1 Monitoring unit for WIC1 relays Test Unit OK Batt. OK WIC1 OK Test 1-617-93 WIC1-TU Anwendung Das Schutzrelais WIC1 überprüft zyklisch die internen Funktionen. Tritt

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

Artikel-Nr.: S201-C4 Code: 2CDS251001R0044. Leitungsschutzschalter - S200-1P - C - 4 A

Artikel-Nr.: S201-C4 Code: 2CDS251001R0044. Leitungsschutzschalter - S200-1P - C - 4 A Artikel-Nr.: S201-C4 Code: 2CDS251001R0044 Leitungsschutzschalter - S200-1P - C - 4 A Kaufen von Electric Automation Network System pro M compact S200 Miniatur-Leistungsschalter mit Strombegrenzung. Sie

Mehr

Distance sensor. Sn = 0,2 6 m

Distance sensor. Sn = 0,2 6 m Sn = 0,2 6 m + Analogausgang + analogue output, Sn = 0,2 6 m für Reflektor mit Analogausgang for use with reflector with analogue output Sn = 0,2 30 m Schaltabstand Operating distance Funktion Operating

Mehr

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Anlage zur Akkreditierungsurkunde D-PL-11055-04-00 nach DIN EN ISO/IEC 17025:2005 Gültigkeitsdauer: 15.10.2014 bis 14.10.2019 Ausstellungsdatum: 15.10.2014 Urkundeninhaber:

Mehr

Designation: UK 5-HESI Short description: Long description: Fuse terminal block for cartridge fuse insert, cross section: mm², AWG: 26-10, width

Designation: UK 5-HESI Short description: Long description: Fuse terminal block for cartridge fuse insert, cross section: mm², AWG: 26-10, width Designation: UK 5-HESI Short description: Long description: Fuse terminal block for cartridge fuse insert, cross section: 0.2 -, AWG: 26-10, width: 8.2 mm, color: black Technical data: General: Number

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Line-intermediate Dimmer Type Schnur-Zwischendimmer Serie Console Push-button Type Truhen-Taster Serie 5120

Line-intermediate Dimmer Type Schnur-Zwischendimmer Serie Console Push-button Type Truhen-Taster Serie 5120 Schnur-Zwischendimmer Serie 8015 Line-intermediate Dimmer Type 8015 230 V, von 40 bis 160 Watt LBH 92 x 28 x 27 mm. Beleuchtet, für Glühlampen. Sicherung F 800 = Flink 800 ma oder 0,8 A 230 V-AC, 40 Watt

Mehr

Ex solenoid interlocks // Ex AZM 415

Ex solenoid interlocks // Ex AZM 415 Features/Options Ex zone 1 and 21 Special version up to +90 C ambient temperature for dust Ex zone 21 available (HU) Two Ex switch inserts in one enclosure Spring-to-lock or power-to-lock principle Problem-free

Mehr

Allgemeine Technische Daten / General Technical Data

Allgemeine Technische Daten / General Technical Data Strom / Current [A] Strom / Current [A] Unterbaufähige Motordrosseln für hohe Kabellängen. Geeignet für Siemens-Umrichter der Serien SINAMICS G120C und G120 mit Leistungsmodul PM240-2 (Standard-Variante).

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS

Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS Typennummer I0FAE3xxF100XxxxxS RFI Filter I0FAE4xxF100XxxxxS Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS Technische Daten Typ E355F E375F E411F 100D... 100D... 100D... Bemessungsstrom [A] 120.0 / 105.0

Mehr

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE 100.000 h geeignet für Zone 2 Ex + 100,000 h suitable for zone 2 hazardous areas + + Für Netz- und Batteriebetrieb For mains and battery supply Lädt und überwacht die Batterie Integrated battery management

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

MS/MA SICHERN MOTORSCHUTZSCHALTER

MS/MA SICHERN MOTORSCHUTZSCHALTER MS/MA SICHERN MOTORSCHUTZSCHALTER TECHNISCHE INFORMATIONEN / AUGUST 207 MOTORSCHUTZSCHALTER MS Technische Daten 3 MOTORSCHUTZSCHALTER MA Technische Daten 6 MOTORSCHUTZSCHALTER MS Technische Daten Vorschriften

Mehr

KOMPETENZBROSCHÜRE Competence brochure

KOMPETENZBROSCHÜRE Competence brochure KOMPETENZBROSCHÜRE Competence brochure We switch the power! Hauptschalter Not-Aus-Schalter S-Reihe mit Unterspannungsauslösung Main switches Emergency-off switches S series with undervoltage release Schalter

Mehr

Batterieladegerät / Battery charger Serie / Series LAB

Batterieladegerät / Battery charger Serie / Series LAB Batterieladegerät / Battery charger Serie / Series LAB Batterieladegerät LAB Battery charger LAB D E Einbau Das LAB ist für industrielle Umgebungen konzipiert und als dreiphasige Ausführung in 24 VDC mit

Mehr

Approbationen UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approbationen UL 508; CSA-C22.2 No ; IEC/EN ; CE marking HauptschalterEinbau Typ P1-25/EA/SVB Art.-Nr. 041097 KatalogNr. SP1-025-DMCRQ Front IP65 Lieferprogramm Sortiment Lasttrennschalter Grundfunktion Hauptschalter Wartungsschalter Reparaturschalter Typkenner

Mehr

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

W Datenblatt: Fehlerstromschutzschalter (FI), Serie BCF0, 10kA

W Datenblatt: Fehlerstromschutzschalter (FI), Serie BCF0, 10kA W Datenblatt: Fehlerstromschutzschalter (FI), Serie BCF0, 10kA W SCHRACK-INFO Kontaktstellungsanzeige Lageunabhängig Netzanschluss beliebig W PRODUKT-INFO Bei Verwendung von V-Fi s entspricht die thermische

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff

Mehr

HauptschalterAufbau. P3-63/I4/SVB Art.-Nr Lieferprogramm IP65. Sortiment Lasttrennschalter

HauptschalterAufbau. P3-63/I4/SVB Art.-Nr Lieferprogramm IP65. Sortiment Lasttrennschalter HauptschalterAufbau Typ P3-63/I4/SVB Art.-Nr. 207343 KatalogNr. SP3-063-I4CRQ IP65 Lieferprogramm Sortiment Lasttrennschalter Grundfunktion Hauptschalter Wartungsschalter Reparaturschalter Typkenner P3

Mehr

Inhaltsverzeichnis Index

Inhaltsverzeichnis Index Inhaltsverzeichnis Index Typ Type Seite Page FDL 7-1 FDR 7-2 FMR 7-3 7-0-1 Zahnradmengenteiler Rotary geared flow divider Zahnradmengenteiler Typ FDL Rotary geared flow divider type FDL Technische Daten

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 DGV - Datenblätter DGV - Datasheets DGV DGV Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] Drehwinkel Rotary angle [ ] Drehmoment Torque [Ncm] DGV-35.95 35/35 x 27.5 95 DGV-50.95

Mehr

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GI-50.10 GI-50.10 1 / Hub / stroke = 10mm 110.5 9 68.5 3x M O 0 M6 18 SW5 O50 O6 Magnet bestromt gezeichnet Solenoid illustrated in energised position 6 max. Hub / stroke = 10mm 110.5 39 68.5 3x M O 0

Mehr

Tachogeneratoren. Gehäuse ø95 mm, lagerlose Ausführung GTB 9. Merkmale. Kurze Reaktionszeit Leerlaufspannung mv pro U/min

Tachogeneratoren. Gehäuse ø95 mm, lagerlose Ausführung GTB 9. Merkmale. Kurze Reaktionszeit Leerlaufspannung mv pro U/min Tachogeneratoren Einseitig offene Hohlwelle 12-16 mm oder Konuswelle 17 mm (1:10) Gehäuse 95 mm, lagerlose Ausführung Merkmale Kurze Reaktionszeit 10...60 mv pro U/min Einseitig offene Hohlwelle 12-16

Mehr

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V B99* C 93 C 99 Applications Overcurrent and short-circuit protection b 3, max. Features Lead-free terminals Manufacturer s logo and type designation stamped on in white Low resistance For rated currents

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Datenblatt. P-series PDU 2.5/4/4AN

Datenblatt. P-series PDU 2.5/4/4AN Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Applicant: Product: Certificate of conformity Generating unit, NS-protection Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN

Mehr

HHD-Sicherungen. HHD Fuses. Hochspannungs-Hochleistungs- High-Voltage HHD. Provided by Northeast Power Systems, Inc.

HHD-Sicherungen. HHD Fuses. Hochspannungs-Hochleistungs- High-Voltage HHD. Provided by Northeast Power Systems, Inc. HHD HHD-Sicherungen Hochspannungs-Hochleistungs- HHD Fuses High-Voltage Einleitung / Introduction Technische Daten nach Baureihen / Technical Data Types of Fuses Technische Daten Sicherungs-Unterteile

Mehr