Thread connections QuickFasten. vortex Flow sensors
|
|
- Hilke Kerner
- vor 5 Jahren
- Abrufe
Transkript
1 JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors 06/06 57
2 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated behind a bluff body immersed in a flow. The vortices detach from the edges of the bluff body and form a Kármán vortex street in the fluid stream. The distance between the single vortices is constant. The frequency of the vortices flowing past a sensor depends on the flow rate and is proportional to the flow. The sensor detects these vortices which are then converted to an electrical frequency signal. Some of the advantages of this measuring principle Minimal flow obstruction low pressure drop Wide range of applications in terms of pressure, temperature and density Independent of the conductivity of the medium High long-term stability / no zero drift Frequency signal Vortex street Sensor Bluff body 58
3 Advantages Solid state flow sensor for liquids with no moving parts no mechanical wear Rugged glass fibre reinforced plastic ensures highest strength and performance Completely encapsulated piezoceramic sensor to detect the vortices thus no direct contact with the medium Wide measuring span (:0) Temperature sensor integrated Output signals: an analogue voltage signal and / or frequency signal is available for the flow, and a resistance or analogue signal is available for the temperature. High interference resistance Wetted parts metal-free 00 % final test with six test points (flow rates) Traceability by serial number Thread connection or QuickFasten 59
4 Vortex flow sensors Series VVX Encapsulated piezoceramic sensor Type VVX5 Technical data VVX5 VVX0 VVX5 Nominal diameter DN 5 DN 0 DN 5 Process connection G¾-ISO 8 male, incl. O-rings optional G½ QuickFasten G ¼-ISO 8 male, incl. O-rings optional G Inner diameter Ø 3 mm Ø 9 mm Ø 5 mm Flow range...40 l/min l/min l/min Accuracy Repeatability Medium Pressure rating ± % of range* ±0,5 % or ± %, see temperature ranges ambient Water and aqueous lotion, deviations with high viscous media PN0 Temperature ranges Medium C, C** Ambient C Repeatability ±0,5 %, C Repeatability ± % Degree of protection EN 6059 Electrical data 5-pin plug M x IP65*** 5-pin RAST.5 IP0*** Electrical connection 5-pin plug connector M x or 5-pin RAST.5 Power supply V DC or 5 V DC (±5 %) Current consumption < 5 ma Approvals Option Recognized component ETL according to UL und CSA Standards Recognized component ETL according to UL und CSA Standards 60
5 Type VVX5 Type VVX0 Poka Yoke Two different versions available: Frequency output Analogue and frequency output Frequency output VVX5 VVX0 VVX5 Output signal flow Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 0 ma Pulse rate 500 /l (optional /l) 00 /l (optional /l) 00 /l (optional /l) Output signal temperature Pt000 wire, class B or NTC 0,74k, B 0/ or none Analogue output VVX5 VVX0 VVX5 Output signal flow Voltage signal 0,5...3,5 V Scaling...40 l/min l/min l/min Voltage rate V / l/min V / l/min V / l/min Output signal temperature Voltage signal 0,5...3,5 V corresponds to C or Pt000 wire, class B or NTC 0.74k, B 0/ or none * Test conditions: Test medium water Media temperature C Inlet pressure bar Defined inlet and outlet pipes (see operating manual) *** With attached cable socket ** Temperature cycle test: -0 C / 70 C, 0 % rh, cycle time.5 h, temperature gradient approx..5 K/min, hold time at -0 C and 70 C 0 min each, 90 cycles: no failures 6
6 Typical pressure drop VVX5 pressure drop p [mbar] flow rate Q [l/min] Typical pressure drop VVX0 pressure drop p [mbar] flow rate Q [l/min] Typical pressure drop VVX5 pressure drop p [mbar] flow rate Q [l/min] 6
7 VVX5 Mx Alternative electrical connection 3 RAST,5 Schlüsselweite nut size 40 G 3/4 A 80 VVX0 VVX5 3 Mx Poka Yoke 6 B Schlüsselweite nut size Mx B n3,8 n44 G /4 A A A 3,5 00 Maßstab : VVX-034K 5 95 Maßstab : VVX-07K Materials in contact with media Body / tube PPS Fortron 40 % GF Sensor ETFE Tefzel O-rings EPDM 63
8 Version frequency output Order code Example VVXAS G A RRRP 5 4 Nominal diameter DN 5 DN 0 DN 5 Power supply V DC 5 V DC Output signal temperature Pt000 NTC 0.74K none Electrical connection 5 pin plug M x RAST.5 plug VVXAS VVXC9S VVXBS G P A B B RRRP RRRN P 6 Version analogue output and frequency output Order code Example VVXASNAU RP 5 4 Nominal diameter DN 5 DN 0 DN 5 Output signal temperature V Pt000 NTC 0.74K none Power supply V DC 5 V DC Electrical connection 5 pin plug M x RAST.5 plug VVXASNAU VVXC9SNBUC VVXBSNBU U RP RN P 6 64
9 3 5 4 (Verwendungsbereich) (Zul. Abw.) (Oberfläche) Maßstab: (Gewicht) (Werkstoff, Halbzeug) Allgemein ISO 768-m DIN ISO 30 (SIKA-Artikelnummer) Datum Name Bearb...04 Graß Gepr Kuelper Norm Dr. Siebert & Kühn GmbH & Co KG Struthweg 7-9 a Toleranzen geä Kü 3460 Kaufungen Zust Änderung Datum Name (Urspr.:) (Ers. f.:) (Ers. d.:) Blatt Bl (Verwendungsbereich) (Zul. Abw.) (Oberfläche) Maßstab: (Gewicht) (Werkstoff, Halbzeug) Allgemein ISO 768-m DIN ISO 30 (SIKA-Artikelnummer) Datum Name Bearb...04 Graß Gepr Kuelper Norm Dr. Siebert & Kühn GmbH & Co KG Struthweg 7-9 a Toleranzen geä Kü 3460 Kaufungen Zust Änderung Datum Name (Urspr.:) (Ers. f.:) (Ers. d.:) Blatt Bl. Accessories Length Order code Connection cable with 5 pin cable socket M x, angle type molded lead 5 x 0.34 mm², sheathing material PVC (T max = 80 C)* Connection cable with 5 pin cable socket M x, molded lead 5 x 0.34 mm², sheathing material PVC, 4 pin Molex MicroBlade wire-to-board housing, (T max = 80 C) PVC-Ribbon cable 5 x AWG4 with RAST.5 duomodul * Connection cable with UL approval on request Accessories VVX5 Screw coupling G½, brass Weitergabe sowie Vervielfältigung dieser Dokumente, Verwertung und Mitteilung ihres Inhalts sind verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. SIKA Unternehmensgruppe, Kaufungen, Deutschland. Any unauthorized copying, disclosure or distribution of this document and its contents is strictly forbidden unless specifically authorised. Any violation will lead to indemnity. All rights reserved, particularly in the event of patent grant, registration of a utility model or design patent. SIKA Company Group, Kaufungen, Germany m m 3 m 5 m 0 m XVVX040 XVVX05 XVVX039 XVVX04 XVVX04.5 m XVVX065 m m XVVX03 XVVX0 Order code** BVVX007 Leitungslängen L (mm) Leitungstyp Art.Nr.: 000 PVC- Steuerleitung 4x0,5mm² (AWG4) PVC-Steuerleitung 4x0,5mm² (AWG4) XVVX065 Anschlussstecker Mx gerade Ausführung VVX-0489 Leitungslängen L (mm) Leitungstyp Art.Nr.: 000 PVC- Steuerleitung 4x0,5mm² (AWG4) PVC-Steuerleitung 4x0,5mm² (AWG4) XVVX065 Anschlussstecker Mx gerade Ausführung VVX-0489 Soldering coupling Ø 5 mm, brass BVVX008 Accessories VVX0 O-ring for QuickFasten, EPDM Order code** XVVX06 Joint clip QuickFasten, stainless steel XVVX05 Accessories VVX5 Screw coupling R, brass Order code** BVVX003 Soldering coupling Ø 8 mm, brass BVVX004 Bonding coupling Ø 5 mm, PVC BVVX005 Screw coupling G, stainless steel.457 BVVX006 ** Supplied piecewise 65
vortex Flow sensors Contains products with:
JJ VVX 15 JJ VVX 25 vortex Flow sensors Contains products with: DS_Vortex_Flow_Sensors 01/2015 55 Vortices for precise flow measurement Function Alternate vortices rotating in opposite directions are generated
MehrThread connections QuickFasten. vortex Flow sensors
JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors /207 59 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated behind
MehrVortex flow sensors. Series VVX. Type VVX20. Type VVX15
Vortex flow sensors Series VVX Type VVX5 Type VVX0 Technical data VVX5 VVX0 VVX5 Nominal pipe size ½ ¾ Process connection ½ NPT ¾ NPT or QuickFasten NPT Inner diameter 0.5 inch 0.75 inch inch Flow range
MehrThread connections QuickFasten. vortex Flow sensors
JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors_USA 07/07 53 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated
MehrMagnetic inductive flow sensors
Magnetic inductive flow sensors Series induq VMI Advantages Robust metal housing Nominal diameter DN 7, DN 1 and DN 2 Wide measuring range 1:6 (1:5) Frequency or analogue and frequency output Delivery
MehrMagnetic inductive flow sensors
Magnetic inductive flow sensors Series induq VMI Advantages Robust metal housing Nominal pipe size ¼, ⅜ and ¾ Wide measuring range 1:6 (1:5) Frequency or analog and frequency output Delivery inlcuding
MehrVVX. VVX20 QuickFasten. Technisches Datenblatt BEST BEST. Durchflussmessung Vortex-Durchflusssensoren. Ihre Vorteile
Durchflussmessung Vortex-Durchflusssensoren VVX VVX20 BEST SELLER VVX20 QuickFasten BEST SELLER Ihre Vorteile Baureihe VVX Kein mechanischer Verschleiß Durchflusssensor ohne bewegte Teile für Wasser Höchste
Mehrvortex durchflusssensoren
JJ Gewindeanschluss JJ QuickFasten vortex durchflusssensoren DB_Vortex_Durchflusssensoren 06/06 57 Vortex Durchflusssensoren Funktionsprinzip Hinter einem umströmten Störkörper entstehen gegenläufige und
MehrTurbine flow sensors. For potable water applications, series VTY10. Type VTY10, brass. Type VTY10, plastic
Series VTY Turbine flow sensors of the series VTY were specially developed for the use in potable water mass production applications. Flexible, customer- and application-oriented customisations to existing
MehrDurchflussmessung Magnetisch Induktive Durchflusssensoren BEST VMI20 SELLER
1 Durchflussmessung Magnetisch Induktive Durchflusssensoren VMI induq VMI7 BEST SELLER VMI2 Ihre Vorteile Baureihe VMI Robustes Metallgehäuse für hohe Temperaturen und Drücke Weiter Messbereich 1:6 (1:5)
MehrPush-in flow sensors. Tap water detection Water treatment Leak detection
Push-in flow sensors Push-in flow sensors of the type VTY, VTH// were specially developed for the installation in fittings and feature an easy and space-saving system integration. Typical applications
MehrAnschlusskopf Typ B / Typ J Winkelsteckverbinder Dieselmotoren-Zeigerthermometer. KombiTemp. Temperaturfühler mit örtlicher Anzeige
JJ Anschlusskopf Typ B / Typ J JJ Winkelsteckverbinder JJ Dieselmotoren-Zeigerthermometer KombiTemp Temperaturfühler mit örtlicher Anzeige DB_KombiTemp / 5 Doppelte Temperaturüberwachung mit nur einer
MehrMAGNETIC INDUCTIVE FLOW SENSORS
JJ Series induq VMM JJ Series induq VMI JJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS DB_Magnetic_Inductive_Flow_Sensors 01/2017 63 Magnetic inductive flow sensors Principle of operation The smart
MehrOEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Heizungswasser
OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Heizungswasser 2 Heizungswasser Typische Anwendung für Strömungsschalter Produkteigenschaften Zuverlässige Pumpenüberwachung Zum Einlöten in
MehrWith pipe tees (inline) Direct installation (insertion) With interchangeable paddles For air flow. flow switches
JJ With pipe tees (inline) JJ Direct installation (insertion) JJ For HVAC applications JJ With interchangeable paddles JJ For air flow flow switches DS_Flow_switches 06/2017 7 Flow switches SIKA has over
MehrSeries VHS / VH6 Series VKS / VK6
JJ Series VHS / VH6 JJ Series VKS / VK6 Level switches DS_Level switches 06/2016 225 Level switches Principle of operation Level switches are the easy and reliable solution for monitoring fluid levels.
MehrSeries VHS / VH6 Series VKS / VK6
JJ Series VHS / VH6 JJ Series VKS / VK6 Level switches DS_Level switches 06/2017 233 Level switches Principle of operation Level switches are the easy and reliable solution for monitoring fluid levels.
MehrSeries Turbotron. Series VTY Push-in flow sensors. Turbine flow sensors
JJ Series Turbotron JJ Series VTR JJ Series VTY JJ Push-in flow sensors Turbine flow sensors DS_Turbine_flow_sensors_USA 3/8 87 Turbine flow sensors Sensor housing Cable Hall effect sensor Pipe section
MehrFor male thread For union nut, type Da / type Dc For plain immersion tubes. Protection tubes
JJ For male thread JJ For union nut, type Da / type Dc JJ For plain immersion tubes Protection tubes DS_Protection_tubes 06/201 129 Reliable and certain We manufacture protection tubes for our industrial
MehrMagnetic inductive flow sensors
Magnetic inductive flow sensors Series induq VMM Advantages Rapid signal processing with a 6-bit microcontroller Password protection Self-test anguage selection: German, English ow-flow suppression Empty
MehrMikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert
NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,
MehrDILO soldering unions
DILO soldering unions are particularly used in factory fabrication area piping. DILO offers a very wide variety of unions. Soldering unions are available either with soldering connections on both ends
Mehrdiameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrMade in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]
NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrSchaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012
fremdgesteuert externally controlled Schaltfunktion function Elektrischer Anschluss M12x1 electrical connector M12x1 Die Ventile arbeiten als Druckwaage und werden im Bypass eingesetzt. Der Mediumsdruck
MehrAccessories // Adapter sleeves // Measuring inserts
1 Temperature Calibration Temperature Calibrators TP Accessories & Options Accessories // Adapter sleeves // Measuring inserts Standard sleeve Infrared sleeve Tub insert Surface sleeve Ø 8 mm brass Accessories
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
Mehr2/2-way solenoid valve - Type 218
- direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrDatenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs
2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with
Mehrdiameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
MehrOEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Trinkwasser
OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Trinkwasser 2 Trinkwasser Typische Anwendungen für Turbinen-Durchflusssensoren Produkteigenschaften Leitungswassermessung für Brauchwasser
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
Mehr2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft
direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direct acting with isolating diaphragm fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite
Mehrdirektgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow
1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
MehrP A max. 100bar A P max. 16bar
1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Schnellentlüftungsventil Nennweite DN 2,0 2,5 Schnellentlüftung DN 6,0 Druckbereich Gehäusewerkstoff
MehrControl shut-off butterfly valves DN 50 DN 400 PN
Features Applications include HEVAC and drinking water systems, sanitary and industrial plants for control or shut-off of water and steam -10...+110 C Leakage rate: tight sealing Control and shut-off butterfly
MehrInhaltsverzeichnis Index
Inhaltsverzeichnis Index Typ Type Seite Page FDL 7-1 FDR 7-2 FMR 7-3 7-0-1 Zahnradmengenteiler Rotary geared flow divider Zahnradmengenteiler Typ FDL Rotary geared flow divider type FDL Technische Daten
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff
Mehr2/2-way plastic solenoid valve - Type 110
- direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 6,0 Druckbereich Sitzventil
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
Mehr2/2-way plastic solenoid valve - Type 104
- direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 1,0 2,5 Druckbereich Gehäusewerkstoff
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135
zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff
MehrFlüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors. Serie/Series L-BV2. Ersatzteilliste Spare part list
Flüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors Ersatzteilliste Spare part list Serie/Series L-BV2 Typ / Type 2BV2060 2BV2061 2BV2070 2BV2071 Gardner Denver Deutschland
MehrInkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung
Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb 25...5000 Impulse pro Umdrehung EEx OG 9 - inkremental Merkmale Drehgeber Inkremental / ATEX /
Mehr0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50
MehrA P max. 16bar P R max. 64bar R P max. 16bar
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich
MehrBaureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich
Mehr2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich
MehrInkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung
Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung
Mehr/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.
EZ-0225-V10 Air Bearing Spindle High accurancy air bearing spindle with direct drive. Equipped with an water-cooled synchronous motor (frequency at nominal speed 400 Hz), Power output 1880 W. Rotary encoder
MehrMagnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87
Magnetventile Solenoid Valves Betätigungsmagnet Typ 64 für Baureihe 64/79///7 Type 64 for Series 64/79///7 Elektrische Daten 64er Magnetsystem Elektrische Ausführung: gemäß VDE 050, VDE 00 Ansprechstrom:
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich
Mehr2/2-way solenoid valve - Type 239
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 10 40 Druckbereich Gehäusewerkstoff Messing Dichtw erkstoff Sitzventil mit
MehrHochstromkontakte High Power Contacts
Hochstromkontakte High Power Contacts Technische Daten Technical Data Mechanische Daten Mechanical Data Steckkraft (Kontaktpaar) Mating force (pair of contacts) Ziehkraft Unmating force Temperaturbereich
MehrPosition switch // ES 95 / EM 95
Features/Options Thermoplastic enclosure Horizontally slotted mounting holes Double insulated X ES 95: Slow action A, change-over contact, change-over contact with overlapping, 2 NC contacts or 2 NO contacts
MehrOverview thermostat/ temperature controller
Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:
MehrDatasheet. Page 1 of 7
Features 20 Encoder Positions 4-way Joystick LED-Illumination high quality signal processing Benefits Tactile multi purpose application premium design Hall Effect technology Applications Multiple switch
MehrWestenberg Wind Tunnels
MiniAir20 Hand measurement device for flow, humidity and temperature The hand measurement device MiniAir20 is used for the acquisition of temperature, relative humidity, revolution and flow velocity such
Mehr[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...
DIGICONTROL- Gerätedatenblatt F-SPT-U www.gfr.de [82252] Kategorie: Sensoren und Wächter Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... Anwendung Der Druckmessumformer F-SPT-U...
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012
Baureihe 786-E Type 786-E fremdgesteuert externally controlled Schaltfunktion: function: NC (stromlos geschlossen) NC (normally closed) Elektrischer Anschluss M12x1 electrical connector M12x1 Bauart stufenlose
MehrTECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor
TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,
Mehrservogesteuert pilot operated
1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung
MehrDatenblatt. P-series PDU 2.5/4/4AN
Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means
MehrBaureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator
Bauart Nennweite DN 8 DN 50 Anschluss Kugelhahn mit pneumatischem Schwenkantrieb G1/4 G2 Betriebsdruck Messing: DN15 DN20 = PN30 DN25 = PN16 DN32 DN50 = PN10 Edelstahl: PN63 Gehäusewerkstoff Armatur: Edelstahl
MehrBarcodescanner CLV62x, CLV63x, CLV64x, CLV65x
T E C H N I S C H E I N F O R M AT I O N Diese Technische Information ergänzt die Betriebsanleitungen der Barcodescanner-Familie CLV6xx mit Angaben zur UL60950-Zertifizierung. Betriebsanleitung CLV62x
MehrKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
MehrUmschaltventile Magnete
Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC
MehrDIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 15 50
MehrZubehör. Accessories. Dichtring STERI-Connect 73 gasket. Dichtring DIN A (DIN 11853) 75 gasket. Sechskantschraubensatz 77 hexagonal screw set
Zubehör Accessories Seite page Dichtring STERI-Connect 73 gasket Dichtring DIN 11864-A (DIN 11853) 75 gasket Sechskantschraubensatz 77 hexagonal screw set Clampklammer 78 heavy duty clamp 72 Dichtring
MehrSignal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen
LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL Sender/Empfänger mit Outdoor-Box Merkmale LWL-SBR, Übertragungsweiten bis zu 1500 m Wandlung üblicher Rechtecksignale
MehrUmschaltventile Magnet
Umschaltventile Magnet DFE1/3 estellnr. Typ 2-11-1 DFE1/318ES-W22-12VDC 2-11-1 DFE1/318ES-W22-24VDC 24-2-116 DFE1/318ES-Y22-12VDC 24-2-117 DFE1/318ES-Y22-24VDC Weitere Umschaltventil Varianten auf nfrage
MehrSpecification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control
Technische Daten BAUFORM Druckgesteuertes Nadelventil mit aufgebautem Stellungsregler PG01. Specification DESIGN Pressure actuated needle valve with electropneumatic positioner. Artikel: AND STEUERFUNKTIONEN
MehrGasring-Vakuumpumpen/- Kompressoren. Serie/Series G-BH1. Ersatzteilliste Spare part list. Typ / Type 2BH1 1
Gasring-Vakuumpumpen/- Kompressoren Ersatzteilliste Spare part list Serie/Series G-BH1 Typ / Type 2BH1 1 Gardner Denver Deutschland GmbH Postfach 1510 97605 Bad Neustadt / Saale Germany Tel.: +49 7622
MehrCompressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3
3/2 Wegeventil mit PIEZO-Pilotventil Baureihe P20 3/2 way valve with Piezo-pilot valve Series P20 P20 381RF-* NW 2 Eigenerwärmungsfrei Ein Produkt für alle Ex-Bereiche Kompatibel zu Microcontrollern Kompatibel
MehrTechnical details subject to change without notice / Tolerances acc. to DIN/ANSI standards, other dimensions approximate
Check Valve B4w / wafer type Check Valve B4w available sizes DN 50 up to DN 250, PN 10, wafer type execution disc replaceable, with reinforced steel inlet for assembling between flanges acc. to DIN EN
MehrELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/
LED-Schaltschrankleuchten LLE-400 und LLE-700 LED Enclosure Lighting LLE-400 and LLE-700 Hochvolt-LED-Technik, Anschluss an 230V AC 2 Varianten: mit Bewegungsmelder oder Türendschalter mit 230V Steckdose
MehrTECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil
TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3
MehrProportional Magnetventil BFW PROPORTIONAL MAGNETVENTILE BFW. Proportional Solenoid Valve BFW. Technische Daten l Technical Data
Proportional Magnetventil BFW Erhältlich in CETOP und CETOP Durchflussmenge CETOP :, oder 7 l/min Durchflussmenge CETOP :, 7 oder l/min Inkl. Befestigungsschrauben und Ventilstecker Grundplatten zu den
MehrTypenreihe GH Lifting Solenoids
Hubmagnete Lifting Solenoids Bauart Hubmagnete der Reihe GH können mit Durchmessern zwischen 5 mm und 65 mm und mit Hublängen von 8 bis 60 mm gefertigt werden. Serien mäßig wer den sie mit Wellenenden
MehrCOUPLING TECHNOLOGY. Water Pneumatic Hydraulic Electrical TYPE COUPLING TECHNOLOGY
Water Pneumatic Hydraulic Electrical Accessories 2 Temperature Range - Temperaturbereich - C +180 C (+ F +356 F) Nitrile (V) - C +0 C (-4 F +2 F) Nitrile (N) - C +0 C (-4 F +2 F) EPDM (E) 0 C +270 C (+23
MehrTechnical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung
Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung 4...7 V 5 V *) Rated Current Nennstrom < 50 ma Sound Output [SPL]at 10 cm Lautstärke[Schalldruckpegel]
MehrERHARD is a company of. Datasheet ERHARD ECR check valve
ERHARD is a company of Datasheet The compact check valve for clamping The is clamped between two flanges as a reflux preventer. It has two vanes which, for example, open on starting a pump and will iediately
MehrKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
MehrIDG. Drehzahlsensor / Speed Sensor
Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor
MehrKühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00
Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00 Inhalt S./P. 1. Beschreibung / Description...
MehrArtikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.
Beschreibung Description: Verteiler nach Vandalengeschützte Einzeltaster für den Einbau in Frontplatten und Gehäuse mit den Einbaumassen 18mm und 22 mm. Bei diesen Ausführungen bestehen sowohl Betätiger
MehrNewest Generation of the BS2 Corrosion/Warning and Measurement System
Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing
Mehr