Thread connections QuickFasten. vortex Flow sensors

Größe: px
Ab Seite anzeigen:

Download "Thread connections QuickFasten. vortex Flow sensors"

Transkript

1 JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors 06/06 57

2 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated behind a bluff body immersed in a flow. The vortices detach from the edges of the bluff body and form a Kármán vortex street in the fluid stream. The distance between the single vortices is constant. The frequency of the vortices flowing past a sensor depends on the flow rate and is proportional to the flow. The sensor detects these vortices which are then converted to an electrical frequency signal. Some of the advantages of this measuring principle Minimal flow obstruction low pressure drop Wide range of applications in terms of pressure, temperature and density Independent of the conductivity of the medium High long-term stability / no zero drift Frequency signal Vortex street Sensor Bluff body 58

3 Advantages Solid state flow sensor for liquids with no moving parts no mechanical wear Rugged glass fibre reinforced plastic ensures highest strength and performance Completely encapsulated piezoceramic sensor to detect the vortices thus no direct contact with the medium Wide measuring span (:0) Temperature sensor integrated Output signals: an analogue voltage signal and / or frequency signal is available for the flow, and a resistance or analogue signal is available for the temperature. High interference resistance Wetted parts metal-free 00 % final test with six test points (flow rates) Traceability by serial number Thread connection or QuickFasten 59

4 Vortex flow sensors Series VVX Encapsulated piezoceramic sensor Type VVX5 Technical data VVX5 VVX0 VVX5 Nominal diameter DN 5 DN 0 DN 5 Process connection G¾-ISO 8 male, incl. O-rings optional G½ QuickFasten G ¼-ISO 8 male, incl. O-rings optional G Inner diameter Ø 3 mm Ø 9 mm Ø 5 mm Flow range...40 l/min l/min l/min Accuracy Repeatability Medium Pressure rating ± % of range* ±0,5 % or ± %, see temperature ranges ambient Water and aqueous lotion, deviations with high viscous media PN0 Temperature ranges Medium C, C** Ambient C Repeatability ±0,5 %, C Repeatability ± % Degree of protection EN 6059 Electrical data 5-pin plug M x IP65*** 5-pin RAST.5 IP0*** Electrical connection 5-pin plug connector M x or 5-pin RAST.5 Power supply V DC or 5 V DC (±5 %) Current consumption < 5 ma Approvals Option Recognized component ETL according to UL und CSA Standards Recognized component ETL according to UL und CSA Standards 60

5 Type VVX5 Type VVX0 Poka Yoke Two different versions available: Frequency output Analogue and frequency output Frequency output VVX5 VVX0 VVX5 Output signal flow Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 0 ma Pulse rate 500 /l (optional /l) 00 /l (optional /l) 00 /l (optional /l) Output signal temperature Pt000 wire, class B or NTC 0,74k, B 0/ or none Analogue output VVX5 VVX0 VVX5 Output signal flow Voltage signal 0,5...3,5 V Scaling...40 l/min l/min l/min Voltage rate V / l/min V / l/min V / l/min Output signal temperature Voltage signal 0,5...3,5 V corresponds to C or Pt000 wire, class B or NTC 0.74k, B 0/ or none * Test conditions: Test medium water Media temperature C Inlet pressure bar Defined inlet and outlet pipes (see operating manual) *** With attached cable socket ** Temperature cycle test: -0 C / 70 C, 0 % rh, cycle time.5 h, temperature gradient approx..5 K/min, hold time at -0 C and 70 C 0 min each, 90 cycles: no failures 6

6 Typical pressure drop VVX5 pressure drop p [mbar] flow rate Q [l/min] Typical pressure drop VVX0 pressure drop p [mbar] flow rate Q [l/min] Typical pressure drop VVX5 pressure drop p [mbar] flow rate Q [l/min] 6

7 VVX5 Mx Alternative electrical connection 3 RAST,5 Schlüsselweite nut size 40 G 3/4 A 80 VVX0 VVX5 3 Mx Poka Yoke 6 B Schlüsselweite nut size Mx B n3,8 n44 G /4 A A A 3,5 00 Maßstab : VVX-034K 5 95 Maßstab : VVX-07K Materials in contact with media Body / tube PPS Fortron 40 % GF Sensor ETFE Tefzel O-rings EPDM 63

8 Version frequency output Order code Example VVXAS G A RRRP 5 4 Nominal diameter DN 5 DN 0 DN 5 Power supply V DC 5 V DC Output signal temperature Pt000 NTC 0.74K none Electrical connection 5 pin plug M x RAST.5 plug VVXAS VVXC9S VVXBS G P A B B RRRP RRRN P 6 Version analogue output and frequency output Order code Example VVXASNAU RP 5 4 Nominal diameter DN 5 DN 0 DN 5 Output signal temperature V Pt000 NTC 0.74K none Power supply V DC 5 V DC Electrical connection 5 pin plug M x RAST.5 plug VVXASNAU VVXC9SNBUC VVXBSNBU U RP RN P 6 64

9 3 5 4 (Verwendungsbereich) (Zul. Abw.) (Oberfläche) Maßstab: (Gewicht) (Werkstoff, Halbzeug) Allgemein ISO 768-m DIN ISO 30 (SIKA-Artikelnummer) Datum Name Bearb...04 Graß Gepr Kuelper Norm Dr. Siebert & Kühn GmbH & Co KG Struthweg 7-9 a Toleranzen geä Kü 3460 Kaufungen Zust Änderung Datum Name (Urspr.:) (Ers. f.:) (Ers. d.:) Blatt Bl (Verwendungsbereich) (Zul. Abw.) (Oberfläche) Maßstab: (Gewicht) (Werkstoff, Halbzeug) Allgemein ISO 768-m DIN ISO 30 (SIKA-Artikelnummer) Datum Name Bearb...04 Graß Gepr Kuelper Norm Dr. Siebert & Kühn GmbH & Co KG Struthweg 7-9 a Toleranzen geä Kü 3460 Kaufungen Zust Änderung Datum Name (Urspr.:) (Ers. f.:) (Ers. d.:) Blatt Bl. Accessories Length Order code Connection cable with 5 pin cable socket M x, angle type molded lead 5 x 0.34 mm², sheathing material PVC (T max = 80 C)* Connection cable with 5 pin cable socket M x, molded lead 5 x 0.34 mm², sheathing material PVC, 4 pin Molex MicroBlade wire-to-board housing, (T max = 80 C) PVC-Ribbon cable 5 x AWG4 with RAST.5 duomodul * Connection cable with UL approval on request Accessories VVX5 Screw coupling G½, brass Weitergabe sowie Vervielfältigung dieser Dokumente, Verwertung und Mitteilung ihres Inhalts sind verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. SIKA Unternehmensgruppe, Kaufungen, Deutschland. Any unauthorized copying, disclosure or distribution of this document and its contents is strictly forbidden unless specifically authorised. Any violation will lead to indemnity. All rights reserved, particularly in the event of patent grant, registration of a utility model or design patent. SIKA Company Group, Kaufungen, Germany m m 3 m 5 m 0 m XVVX040 XVVX05 XVVX039 XVVX04 XVVX04.5 m XVVX065 m m XVVX03 XVVX0 Order code** BVVX007 Leitungslängen L (mm) Leitungstyp Art.Nr.: 000 PVC- Steuerleitung 4x0,5mm² (AWG4) PVC-Steuerleitung 4x0,5mm² (AWG4) XVVX065 Anschlussstecker Mx gerade Ausführung VVX-0489 Leitungslängen L (mm) Leitungstyp Art.Nr.: 000 PVC- Steuerleitung 4x0,5mm² (AWG4) PVC-Steuerleitung 4x0,5mm² (AWG4) XVVX065 Anschlussstecker Mx gerade Ausführung VVX-0489 Soldering coupling Ø 5 mm, brass BVVX008 Accessories VVX0 O-ring for QuickFasten, EPDM Order code** XVVX06 Joint clip QuickFasten, stainless steel XVVX05 Accessories VVX5 Screw coupling R, brass Order code** BVVX003 Soldering coupling Ø 8 mm, brass BVVX004 Bonding coupling Ø 5 mm, PVC BVVX005 Screw coupling G, stainless steel.457 BVVX006 ** Supplied piecewise 65

vortex Flow sensors Contains products with:

vortex Flow sensors Contains products with: JJ VVX 15 JJ VVX 25 vortex Flow sensors Contains products with: DS_Vortex_Flow_Sensors 01/2015 55 Vortices for precise flow measurement Function Alternate vortices rotating in opposite directions are generated

Mehr

Thread connections QuickFasten. vortex Flow sensors

Thread connections QuickFasten. vortex Flow sensors JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors /207 59 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated behind

Mehr

Vortex flow sensors. Series VVX. Type VVX20. Type VVX15

Vortex flow sensors. Series VVX. Type VVX20. Type VVX15 Vortex flow sensors Series VVX Type VVX5 Type VVX0 Technical data VVX5 VVX0 VVX5 Nominal pipe size ½ ¾ Process connection ½ NPT ¾ NPT or QuickFasten NPT Inner diameter 0.5 inch 0.75 inch inch Flow range

Mehr

Thread connections QuickFasten. vortex Flow sensors

Thread connections QuickFasten. vortex Flow sensors JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors_USA 07/07 53 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated

Mehr

Magnetic inductive flow sensors

Magnetic inductive flow sensors Magnetic inductive flow sensors Series induq VMI Advantages Robust metal housing Nominal diameter DN 7, DN 1 and DN 2 Wide measuring range 1:6 (1:5) Frequency or analogue and frequency output Delivery

Mehr

Magnetic inductive flow sensors

Magnetic inductive flow sensors Magnetic inductive flow sensors Series induq VMI Advantages Robust metal housing Nominal pipe size ¼, ⅜ and ¾ Wide measuring range 1:6 (1:5) Frequency or analog and frequency output Delivery inlcuding

Mehr

VVX. VVX20 QuickFasten. Technisches Datenblatt BEST BEST. Durchflussmessung Vortex-Durchflusssensoren. Ihre Vorteile

VVX. VVX20 QuickFasten. Technisches Datenblatt BEST BEST. Durchflussmessung Vortex-Durchflusssensoren. Ihre Vorteile Durchflussmessung Vortex-Durchflusssensoren VVX VVX20 BEST SELLER VVX20 QuickFasten BEST SELLER Ihre Vorteile Baureihe VVX Kein mechanischer Verschleiß Durchflusssensor ohne bewegte Teile für Wasser Höchste

Mehr

vortex durchflusssensoren

vortex durchflusssensoren JJ Gewindeanschluss JJ QuickFasten vortex durchflusssensoren DB_Vortex_Durchflusssensoren 06/06 57 Vortex Durchflusssensoren Funktionsprinzip Hinter einem umströmten Störkörper entstehen gegenläufige und

Mehr

Turbine flow sensors. For potable water applications, series VTY10. Type VTY10, brass. Type VTY10, plastic

Turbine flow sensors. For potable water applications, series VTY10. Type VTY10, brass. Type VTY10, plastic Series VTY Turbine flow sensors of the series VTY were specially developed for the use in potable water mass production applications. Flexible, customer- and application-oriented customisations to existing

Mehr

Durchflussmessung Magnetisch Induktive Durchflusssensoren BEST VMI20 SELLER

Durchflussmessung Magnetisch Induktive Durchflusssensoren BEST VMI20 SELLER 1 Durchflussmessung Magnetisch Induktive Durchflusssensoren VMI induq VMI7 BEST SELLER VMI2 Ihre Vorteile Baureihe VMI Robustes Metallgehäuse für hohe Temperaturen und Drücke Weiter Messbereich 1:6 (1:5)

Mehr

Push-in flow sensors. Tap water detection Water treatment Leak detection

Push-in flow sensors. Tap water detection Water treatment Leak detection Push-in flow sensors Push-in flow sensors of the type VTY, VTH// were specially developed for the installation in fittings and feature an easy and space-saving system integration. Typical applications

Mehr

Anschlusskopf Typ B / Typ J Winkelsteckverbinder Dieselmotoren-Zeigerthermometer. KombiTemp. Temperaturfühler mit örtlicher Anzeige

Anschlusskopf Typ B / Typ J Winkelsteckverbinder Dieselmotoren-Zeigerthermometer. KombiTemp. Temperaturfühler mit örtlicher Anzeige JJ Anschlusskopf Typ B / Typ J JJ Winkelsteckverbinder JJ Dieselmotoren-Zeigerthermometer KombiTemp Temperaturfühler mit örtlicher Anzeige DB_KombiTemp / 5 Doppelte Temperaturüberwachung mit nur einer

Mehr

MAGNETIC INDUCTIVE FLOW SENSORS

MAGNETIC INDUCTIVE FLOW SENSORS JJ Series induq VMM JJ Series induq VMI JJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS DB_Magnetic_Inductive_Flow_Sensors 01/2017 63 Magnetic inductive flow sensors Principle of operation The smart

Mehr

OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Heizungswasser

OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Heizungswasser OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Heizungswasser 2 Heizungswasser Typische Anwendung für Strömungsschalter Produkteigenschaften Zuverlässige Pumpenüberwachung Zum Einlöten in

Mehr

With pipe tees (inline) Direct installation (insertion) With interchangeable paddles For air flow. flow switches

With pipe tees (inline) Direct installation (insertion) With interchangeable paddles For air flow. flow switches JJ With pipe tees (inline) JJ Direct installation (insertion) JJ For HVAC applications JJ With interchangeable paddles JJ For air flow flow switches DS_Flow_switches 06/2017 7 Flow switches SIKA has over

Mehr

Series VHS / VH6 Series VKS / VK6

Series VHS / VH6 Series VKS / VK6 JJ Series VHS / VH6 JJ Series VKS / VK6 Level switches DS_Level switches 06/2016 225 Level switches Principle of operation Level switches are the easy and reliable solution for monitoring fluid levels.

Mehr

Series VHS / VH6 Series VKS / VK6

Series VHS / VH6 Series VKS / VK6 JJ Series VHS / VH6 JJ Series VKS / VK6 Level switches DS_Level switches 06/2017 233 Level switches Principle of operation Level switches are the easy and reliable solution for monitoring fluid levels.

Mehr

Series Turbotron. Series VTY Push-in flow sensors. Turbine flow sensors

Series Turbotron. Series VTY Push-in flow sensors. Turbine flow sensors JJ Series Turbotron JJ Series VTR JJ Series VTY JJ Push-in flow sensors Turbine flow sensors DS_Turbine_flow_sensors_USA 3/8 87 Turbine flow sensors Sensor housing Cable Hall effect sensor Pipe section

Mehr

For male thread For union nut, type Da / type Dc For plain immersion tubes. Protection tubes

For male thread For union nut, type Da / type Dc For plain immersion tubes. Protection tubes JJ For male thread JJ For union nut, type Da / type Dc JJ For plain immersion tubes Protection tubes DS_Protection_tubes 06/201 129 Reliable and certain We manufacture protection tubes for our industrial

Mehr

Magnetic inductive flow sensors

Magnetic inductive flow sensors Magnetic inductive flow sensors Series induq VMM Advantages Rapid signal processing with a 6-bit microcontroller Password protection Self-test anguage selection: German, English ow-flow suppression Empty

Mehr

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,

Mehr

DILO soldering unions

DILO soldering unions DILO soldering unions are particularly used in factory fabrication area piping. DILO offers a very wide variety of unions. Soldering unions are available either with soldering connections on both ends

Mehr

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar] NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012 fremdgesteuert externally controlled Schaltfunktion function Elektrischer Anschluss M12x1 electrical connector M12x1 Die Ventile arbeiten als Druckwaage und werden im Bypass eingesetzt. Der Mediumsdruck

Mehr

Accessories // Adapter sleeves // Measuring inserts

Accessories // Adapter sleeves // Measuring inserts 1 Temperature Calibration Temperature Calibrators TP Accessories & Options Accessories // Adapter sleeves // Measuring inserts Standard sleeve Infrared sleeve Tub insert Surface sleeve Ø 8 mm brass Accessories

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

2/2-way solenoid valve - Type 218

2/2-way solenoid valve - Type 218 - direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs 2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with

Mehr

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Trinkwasser

OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Trinkwasser OEM Sensoren für Hersteller von Klima- & Trinkwasser-Systemen Trinkwasser 2 Trinkwasser Typische Anwendungen für Turbinen-Durchflusssensoren Produkteigenschaften Leitungswassermessung für Brauchwasser

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direct acting with isolating diaphragm fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite

Mehr

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow 1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

P A max. 100bar A P max. 16bar

P A max. 100bar A P max. 16bar 1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Schnellentlüftungsventil Nennweite DN 2,0 2,5 Schnellentlüftung DN 6,0 Druckbereich Gehäusewerkstoff

Mehr

Control shut-off butterfly valves DN 50 DN 400 PN

Control shut-off butterfly valves DN 50 DN 400 PN Features Applications include HEVAC and drinking water systems, sanitary and industrial plants for control or shut-off of water and steam -10...+110 C Leakage rate: tight sealing Control and shut-off butterfly

Mehr

Inhaltsverzeichnis Index

Inhaltsverzeichnis Index Inhaltsverzeichnis Index Typ Type Seite Page FDL 7-1 FDR 7-2 FMR 7-3 7-0-1 Zahnradmengenteiler Rotary geared flow divider Zahnradmengenteiler Typ FDL Rotary geared flow divider type FDL Technische Daten

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff

Mehr

2/2-way plastic solenoid valve - Type 110

2/2-way plastic solenoid valve - Type 110 - direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 6,0 Druckbereich Sitzventil

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

2/2-way plastic solenoid valve - Type 104

2/2-way plastic solenoid valve - Type 104 - direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 1,0 2,5 Druckbereich Gehäusewerkstoff

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135 zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff

Mehr

Flüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors. Serie/Series L-BV2. Ersatzteilliste Spare part list

Flüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors. Serie/Series L-BV2. Ersatzteilliste Spare part list Flüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors Ersatzteilliste Spare part list Serie/Series L-BV2 Typ / Type 2BV2060 2BV2061 2BV2070 2BV2071 Gardner Denver Deutschland

Mehr

Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung

Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb 25...5000 Impulse pro Umdrehung EEx OG 9 - inkremental Merkmale Drehgeber Inkremental / ATEX /

Mehr

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50

Mehr

A P max. 16bar P R max. 64bar R P max. 16bar

A P max. 16bar P R max. 64bar R P max. 16bar direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung

Mehr

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten. EZ-0225-V10 Air Bearing Spindle High accurancy air bearing spindle with direct drive. Equipped with an water-cooled synchronous motor (frequency at nominal speed 400 Hz), Power output 1880 W. Rotary encoder

Mehr

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87 Magnetventile Solenoid Valves Betätigungsmagnet Typ 64 für Baureihe 64/79///7 Type 64 for Series 64/79///7 Elektrische Daten 64er Magnetsystem Elektrische Ausführung: gemäß VDE 050, VDE 00 Ansprechstrom:

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich

Mehr

2/2-way solenoid valve - Type 239

2/2-way solenoid valve - Type 239 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 10 40 Druckbereich Gehäusewerkstoff Messing Dichtw erkstoff Sitzventil mit

Mehr

Hochstromkontakte High Power Contacts

Hochstromkontakte High Power Contacts Hochstromkontakte High Power Contacts Technische Daten Technical Data Mechanische Daten Mechanical Data Steckkraft (Kontaktpaar) Mating force (pair of contacts) Ziehkraft Unmating force Temperaturbereich

Mehr

Position switch // ES 95 / EM 95

Position switch // ES 95 / EM 95 Features/Options Thermoplastic enclosure Horizontally slotted mounting holes Double insulated X ES 95: Slow action A, change-over contact, change-over contact with overlapping, 2 NC contacts or 2 NO contacts

Mehr

Overview thermostat/ temperature controller

Overview thermostat/ temperature controller Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:

Mehr

Datasheet. Page 1 of 7

Datasheet. Page 1 of 7 Features 20 Encoder Positions 4-way Joystick LED-Illumination high quality signal processing Benefits Tactile multi purpose application premium design Hall Effect technology Applications Multiple switch

Mehr

Westenberg Wind Tunnels

Westenberg Wind Tunnels MiniAir20 Hand measurement device for flow, humidity and temperature The hand measurement device MiniAir20 is used for the acquisition of temperature, relative humidity, revolution and flow velocity such

Mehr

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... DIGICONTROL- Gerätedatenblatt F-SPT-U www.gfr.de [82252] Kategorie: Sensoren und Wächter Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... Anwendung Der Druckmessumformer F-SPT-U...

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012 Baureihe 786-E Type 786-E fremdgesteuert externally controlled Schaltfunktion: function: NC (stromlos geschlossen) NC (normally closed) Elektrischer Anschluss M12x1 electrical connector M12x1 Bauart stufenlose

Mehr

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,

Mehr

servogesteuert pilot operated

servogesteuert pilot operated 1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung

Mehr

Datenblatt. P-series PDU 2.5/4/4AN

Datenblatt. P-series PDU 2.5/4/4AN Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means

Mehr

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator Bauart Nennweite DN 8 DN 50 Anschluss Kugelhahn mit pneumatischem Schwenkantrieb G1/4 G2 Betriebsdruck Messing: DN15 DN20 = PN30 DN25 = PN16 DN32 DN50 = PN10 Edelstahl: PN63 Gehäusewerkstoff Armatur: Edelstahl

Mehr

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x T E C H N I S C H E I N F O R M AT I O N Diese Technische Information ergänzt die Betriebsanleitungen der Barcodescanner-Familie CLV6xx mit Angaben zur UL60950-Zertifizierung. Betriebsanleitung CLV62x

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

Umschaltventile Magnete

Umschaltventile Magnete Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC

Mehr

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 15 50

Mehr

Zubehör. Accessories. Dichtring STERI-Connect 73 gasket. Dichtring DIN A (DIN 11853) 75 gasket. Sechskantschraubensatz 77 hexagonal screw set

Zubehör. Accessories. Dichtring STERI-Connect 73 gasket. Dichtring DIN A (DIN 11853) 75 gasket. Sechskantschraubensatz 77 hexagonal screw set Zubehör Accessories Seite page Dichtring STERI-Connect 73 gasket Dichtring DIN 11864-A (DIN 11853) 75 gasket Sechskantschraubensatz 77 hexagonal screw set Clampklammer 78 heavy duty clamp 72 Dichtring

Mehr

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL Sender/Empfänger mit Outdoor-Box Merkmale LWL-SBR, Übertragungsweiten bis zu 1500 m Wandlung üblicher Rechtecksignale

Mehr

Umschaltventile Magnet

Umschaltventile Magnet Umschaltventile Magnet DFE1/3 estellnr. Typ 2-11-1 DFE1/318ES-W22-12VDC 2-11-1 DFE1/318ES-W22-24VDC 24-2-116 DFE1/318ES-Y22-12VDC 24-2-117 DFE1/318ES-Y22-24VDC Weitere Umschaltventil Varianten auf nfrage

Mehr

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control Technische Daten BAUFORM Druckgesteuertes Nadelventil mit aufgebautem Stellungsregler PG01. Specification DESIGN Pressure actuated needle valve with electropneumatic positioner. Artikel: AND STEUERFUNKTIONEN

Mehr

Gasring-Vakuumpumpen/- Kompressoren. Serie/Series G-BH1. Ersatzteilliste Spare part list. Typ / Type 2BH1 1

Gasring-Vakuumpumpen/- Kompressoren. Serie/Series G-BH1. Ersatzteilliste Spare part list. Typ / Type 2BH1 1 Gasring-Vakuumpumpen/- Kompressoren Ersatzteilliste Spare part list Serie/Series G-BH1 Typ / Type 2BH1 1 Gardner Denver Deutschland GmbH Postfach 1510 97605 Bad Neustadt / Saale Germany Tel.: +49 7622

Mehr

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3 3/2 Wegeventil mit PIEZO-Pilotventil Baureihe P20 3/2 way valve with Piezo-pilot valve Series P20 P20 381RF-* NW 2 Eigenerwärmungsfrei Ein Produkt für alle Ex-Bereiche Kompatibel zu Microcontrollern Kompatibel

Mehr

Technical details subject to change without notice / Tolerances acc. to DIN/ANSI standards, other dimensions approximate

Technical details subject to change without notice / Tolerances acc. to DIN/ANSI standards, other dimensions approximate Check Valve B4w / wafer type Check Valve B4w available sizes DN 50 up to DN 250, PN 10, wafer type execution disc replaceable, with reinforced steel inlet for assembling between flanges acc. to DIN EN

Mehr

ELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/

ELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/ LED-Schaltschrankleuchten LLE-400 und LLE-700 LED Enclosure Lighting LLE-400 and LLE-700 Hochvolt-LED-Technik, Anschluss an 230V AC 2 Varianten: mit Bewegungsmelder oder Türendschalter mit 230V Steckdose

Mehr

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3

Mehr

Proportional Magnetventil BFW PROPORTIONAL MAGNETVENTILE BFW. Proportional Solenoid Valve BFW. Technische Daten l Technical Data

Proportional Magnetventil BFW PROPORTIONAL MAGNETVENTILE BFW. Proportional Solenoid Valve BFW. Technische Daten l Technical Data Proportional Magnetventil BFW Erhältlich in CETOP und CETOP Durchflussmenge CETOP :, oder 7 l/min Durchflussmenge CETOP :, 7 oder l/min Inkl. Befestigungsschrauben und Ventilstecker Grundplatten zu den

Mehr

Typenreihe GH Lifting Solenoids

Typenreihe GH Lifting Solenoids Hubmagnete Lifting Solenoids Bauart Hubmagnete der Reihe GH können mit Durchmessern zwischen 5 mm und 65 mm und mit Hublängen von 8 bis 60 mm gefertigt werden. Serien mäßig wer den sie mit Wellenenden

Mehr

COUPLING TECHNOLOGY. Water Pneumatic Hydraulic Electrical TYPE COUPLING TECHNOLOGY

COUPLING TECHNOLOGY.   Water Pneumatic Hydraulic Electrical TYPE COUPLING TECHNOLOGY Water Pneumatic Hydraulic Electrical Accessories 2 Temperature Range - Temperaturbereich - C +180 C (+ F +356 F) Nitrile (V) - C +0 C (-4 F +2 F) Nitrile (N) - C +0 C (-4 F +2 F) EPDM (E) 0 C +270 C (+23

Mehr

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung 4...7 V 5 V *) Rated Current Nennstrom < 50 ma Sound Output [SPL]at 10 cm Lautstärke[Schalldruckpegel]

Mehr

ERHARD is a company of. Datasheet ERHARD ECR check valve

ERHARD is a company of. Datasheet ERHARD ECR check valve ERHARD is a company of Datasheet The compact check valve for clamping The is clamped between two flanges as a reflux preventer. It has two vanes which, for example, open on starting a pump and will iediately

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

IDG. Drehzahlsensor / Speed Sensor

IDG. Drehzahlsensor / Speed Sensor Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor

Mehr

Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00

Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00 Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00 Inhalt S./P. 1. Beschreibung / Description...

Mehr

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert. Beschreibung Description: Verteiler nach Vandalengeschützte Einzeltaster für den Einbau in Frontplatten und Gehäuse mit den Einbaumassen 18mm und 22 mm. Bei diesen Ausführungen bestehen sowohl Betätiger

Mehr

Newest Generation of the BS2 Corrosion/Warning and Measurement System