for Converters and Power Electronics

Größe: px
Ab Seite anzeigen:

Download "for Converters and Power Electronics"

Transkript

1 or Converters and Power Electronics Power line ilters or single-phase systems Rated voltage 25 V~, 5/ Hz Rated current 8 A to 25 A Construction Two-line ilter Metal case Features Very high insertion loss due to two-stage construction ow leakage current Easy to install Degree o protection: IP 2 1) Design complies with E 133 2, U 1283, CSA 22.2 o Optimized or long motor cables and operation under ull load Applications Frequency converters or motor drives, e.g. elevators conveyor systems pumps traction systems HVAC systems (heating, ventilation and air conditioning) Power supplies Terminals Sae-to-touch terminal blocks on component: Manuacturer s logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging: Manuacturer s logo, ordering code 1) In accordance with IEC 529: 1989; E 529: 1991; DI VDE /1

2 or Converters and Power Electronics Typical circuit diagram OAD SSB772-K Technical data Rated voltage V R Rated current I R Test voltage V P Overload capability eakage current I leak Climatic category 25 V~, 5/ Hz Reerred to C ambient temperature 177 V, 2 s (line/line) 27 V, 2 s (lines/case) 1,5 I R or 3 min per hour or 2,5 I R or 3 s per hour at 25 V~, 5 Hz 25/1/21 ( 25 C/+ 1 C/21 days damp heat test) in accordance with E 68-1 Characteristics and ordering codes I R A Terminal cross section mm 2 I leak ma R typ mω Approx. weight kg Ordering code 8 4 < 3,5 42 1,35 B84142-B8-R 12 4 < 3,5 3 1,45 B84142-B12-R 16 4 < 3,5 21 1,45 B84142-B16-R 25 1 < 3,5 9 3,7 B84142-B25-R 18 3/1

3 or Converters and Power Electronics Dimensional drawing B84142-B8-R B84142-B16-R 2,5±,5 32 max. 61 max. 144 max. 7±,3,8±,2 86 max. 113 max. 31 max. PE OAD PE 1±,3 Terminal blocks 4 mm² 5,8±,2 121 max. SSB774-2 Dimensional drawing B84142-B25-R PE M6 x max. 7±,3 34±,5 ±1,8 31 max. 86 max. 113 max. 24±1 15±1 81 max. PE 1 OAD 5,8 PE 1 1±,3 Terminal blocks 1 mm max. SSB773-T 181 3/1

4 or Converters and Power Electronics Insertion loss (typical values at Z = 5 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dierential mode (symmetrical) B84142-B8-R 1 SSB777-R B84142-B12-R 1 SSB778-Z Hz Hz 1 8 B84142-B16-R 1 SSB775-A B84142-B25-R 1 SSB776-I Hz Hz /1

5 Herausgegeben von EPCOS AG Marketing Kommunikation, Postach , München, DEUTSCHAD EPCOS AG 2. Alle Rechte vorbehalten. Vervielältigung, Veröentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente speziiziert, keine Eigenschaten zugesichert. Bestellungen unterliegen den vom ZVEI empohlenen Allgemeinen ieerbedingungen ür Erzeugnisse und eistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und ieermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaten im Ausland. Bauelemente können augrund technischer Erordernisse Geahrstoe enthalten. Auskünte darüber bitten wir unter Angabe des betreenden Typs ebenalls über die zuständige Vertriebsgesellschat einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box , Munich, GERMAY EPCOS AG 2. All Rights Reserved. Reproduction, publication and dissemination o this brochure and the inormation contained therein without EPCOS prior express consent is prohibited. The inormation contained in this brochure describes the type o component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions or the Supply o Products and Services o the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manuacturers Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Oices o EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For inormation on the type in question please also contact one o our Sales Oices. 1

3-Line Filters for Converters and Power Electronics B84143-B*-R110 B84143-B*-R112

3-Line Filters for Converters and Power Electronics B84143-B*-R110 B84143-B*-R112 B83-B*-R Power line ilters or three-phase systems Rated voltage /275 and 5/ V~, / Hz Rated current 8 to A Construction Three-line ilter Metal case Book size Features Very high insertion loss Low leakage

Mehr

for Installations and Systems

for Installations and Systems or Installations and Systems Power line ilters or three-phase systems Rated voltage 4/25 V~, 5/ Hz Rated voltage 6 to 125 A Construction Four-line ilter Metal case Features High insertion loss Compact,

Mehr

3-Line Filters for Converters and Power Electronics B84143-G*-R110 B84143-G*-R112

3-Line Filters for Converters and Power Electronics B84143-G*-R110 B84143-G*-R112 B8443-G*-R0 B8443-G*-R2 Power line filters for three-phase systems Rated voltage 4/275 and 520/300 V~, 50/ Hz Rated current 8 to 220 A Construction Three-line filter Metal case Book size Features High

Mehr

SIFI-A Series. SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A

SIFI-A Series. SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A 2-ine Filters SIFI- Series 4111 SIFI- for normal insertion loss Rated voltage 2 V~, / Hz Rated current 1 to Construction Two-line filter Metal case Polyurethane potting (U 94 V-) Features Compact design

Mehr

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V

Overcurrent Protection Leaded Disks, Coated, 12 V, 24 V B99* C 93 C 99 Applications Overcurrent and short-circuit protection b 3, max. Features Lead-free terminals Manufacturer s logo and type designation stamped on in white Low resistance For rated currents

Mehr

P V W/set N / 20 % 2530 B66317-G-X130 N / 20 % < 0,59

P V W/set N / 20 % 2530 B66317-G-X130 N / 20 % < 0,59 Core B66317 In accordance with IEC 61246 E cores are supplied as single units Magnetic characteristics (per set) Σl/A = 1,1 mm 1 l e = 57,5 mm A e = 52,5 mm 2 A min = 51,5 mm 2 V e = 3 020 mm 3 Approx.

Mehr

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3 Core B66361 In accordance with IEC 61185 Quality assurance per UTE 83313-001/ CECC 25 301-001 (material N27) For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied

Mehr

P V W/set N / 20 % 2460 B66311-G-X130 N / 20 % < 0,27

P V W/set N / 20 % 2460 B66311-G-X130 N / 20 % < 0,27 Core B663 In accordance with IEC 6246 E cores are supplied as single units Magnetic characteristics (per set) Σl/A =,44 mm l e = 46,3 mm A e = 32, mm 2 A min = 3,9 mm 2 V e = 490 mm 3 Approx. weight 7,3

Mehr

Sensors Motor Protection, Triple Sensors

Sensors Motor Protection, Triple Sensors B900 M 00 Applications Thermal protection of winding in electric motors Limit temperature monitoring Features Thermistor pellets with insulating encapsulation in series connection (triple sensor) Low-resistance

Mehr

P 4,6 4,1. Magnetic characteristics (per set) Σl/A = 2,6 mm 1 l e = 7,6 mm A e = 2,8 mm 2 V e = 21,3 mm 3. Approx. weight 0,17 g/set.

P 4,6 4,1. Magnetic characteristics (per set) Σl/A = 2,6 mm 1 l e = 7,6 mm A e = 2,8 mm 2 V e = 21,3 mm 3. Approx. weight 0,17 g/set. Core B65495 Miniature pot cores for adjustable miniature inductors One of the two cores is equipped with an internal thread for the adjusting screw The unit can be fixed to the terminal carrier by glue

Mehr

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx.

EP 13. Magnetic characteristics (per set) Σl/A = 1,24 mm 1 l e = 24,2 mm A e = 19,5 mm 2 A min = 14,9 mm 2 V e = 472 mm 3. Approx. Core B65843 In accordance with IEC 61596 For transformers featuring high inductance and low overall height For power applications EP cores are supplied in sets Magnetic characteristics (per set) Σl/A =

Mehr

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Construction Round varistor element, leaded Coating: epoxy resin, flame-retardant

Mehr

mm 1 mm mm 2 mm 3 P V

mm 1 mm mm 2 mm 3 P V Core B6553 In accordance with IEC 6033 Pot cores are supplied in sets Magnetic characteristics (per set) Σl/A l e A e A min V e with center hole,0 5,9 5,9 252,0 Approx. weight (per set) without center

Mehr

The following products presented in this data sheet are being withdrawn. B66307F0000X142 B66307F0000X

The following products presented in this data sheet are being withdrawn. B66307F0000X142 B66307F0000X E/ELP Cores Series/Type: E 16/8/5 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B66307F0000X142

Mehr

EMI Suppression Capacitors X2 / 275 and 300 Vac B3292 B32922 X2 MKP/SH 40/100/21/C

EMI Suppression Capacitors X2 / 275 and 300 Vac B3292 B32922 X2 MKP/SH 40/100/21/C EMI Suppression Capacitors X2 / 275 and 300 Vac B3292 X2 capacitors with very small dimensions Rated ac voltage 275 and 300 V, 50/60 Hz Construction Dielectric: polypropylene (MKP) Plastic case (UL 94

Mehr

ETD 29/16/10 Core B66358 _ 9,8 0,6

ETD 29/16/10 Core B66358 _ 9,8 0,6 Core ETD 29/16/10 through ETD 59/31/22 In accordance with IEC 61185 For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied as single units Magnetic characteristics

Mehr

SMD Varistors Monolithic; Standard Series

SMD Varistors Monolithic; Standard Series Construction Cylindrical varistor element, encapsulated Encapsulation: thermoplast, flame-retardant to UL 94-0 Termination: tinned copper alloy Features Electrical equivalents to leaded types S05/S07 up

Mehr

SIMID 1210-100. Size 1210 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 100 µh Rated current 65 to 800 ma

SIMID 1210-100. Size 1210 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 100 µh Rated current 65 to 800 ma Size 12 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 0 µh Rated current 65 to 800 ma Construction Ceramic or ferrite core Laser-welded winding Flame-retardant encapsulation Features Very wide temperature

Mehr

The following products presented in this data sheet are being withdrawn. B65816D

The following products presented in this data sheet are being withdrawn. B65816D RM Cores Series/Type: RM 12 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B65816D20050000

Mehr

Single-Ended Capacitors Very Low Impedance 105 C B41858

Single-Ended Capacitors Very Low Impedance 105 C B41858 Single-Ended Capacitors Very Low Impedance 5 C Long-life grade capacitors for professional applications Applications For use in output circuits of switch-mode power supplies of compact design For professional

Mehr

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3

ETD 34/17/11. Magnetic characteristics (per set) Σl/A = 0,81 mm 1 l e = 78,6 mm A e = 97,1 mm 2 A min = 91,6 mm 2 V e = mm 3 Core B66361 In accordance with IEC 61185 Quality assurance per UTE 83313-001/ CECC 25 301-001 (material N27) For SMPS transformers with optimum weight/performance ratio at small volume ETD cores are supplied

Mehr

mm 1 mm mm 2 mm 3 µ e Ordering code

mm 1 mm mm 2 mm 3 µ e Ordering code Core B65517 In accordance with IEC 60133 Pot cores are supplied in sets Magnetic characteristics (per set) Σl/A l e A e A min V e with center hole 1,25 12,2 9,8 120 without center hole 1,13 13,4 11,9 9,3

Mehr

mm 1 mm mm 2 mm 3 P V

mm 1 mm mm 2 mm 3 P V Core B65671 In accordance with IEC 60133 Pot cores are supplied in sets Magnetic characteristics (per set) Σl/A l e A e A min V e Approx. weight (per set) Gapped with center hole 0,4 37,2 93 76,5 3 460

Mehr

EMI Suppression Capacitors X2 / 275 Vac

EMI Suppression Capacitors X2 / 275 Vac EMI Suppression Capacitors X2 / B81130 X2 capacitors with very small dimensions Rated ac voltage 275 V, 50/60 Hz Construction ielectric: polypropylene (MKP) Plastic case (UL 94 V-0) Epoxy resin sealing,

Mehr

EMI Suppression Capacitors Y2 / 250 Vac

EMI Suppression Capacitors Y2 / 250 Vac EMI Suppression Capacitors Y2 / B81122 Y2 capacitors Rated ac voltage 250 V, 50/60 Hz Construction Dielectric: for = 10 mm: polyester (MKT), for 15 mm: polypropylene (MKP) Internal series connection (for

Mehr

B81133 X2 MKT/SH 40/100/21/C B81133 X2 MKT/SH 40/100/21/C. EMI Suppression Capacitors X2 / 275 Vac Not for new design

B81133 X2 MKT/SH 40/100/21/C B81133 X2 MKT/SH 40/100/21/C. EMI Suppression Capacitors X2 / 275 Vac Not for new design EMI Suppression Capacitors X2 / X2 capacitors with small dimensions Rated ac voltage 275 V, 50/60 Hz 1) Construction Dielectric: polyester (MKT) Internal series connection Plastic case (UL 94 V-0) Epoxy

Mehr

Overcurrent Protection Leaded Disks, Uncoated, 380 V to 1000 V

Overcurrent Protection Leaded Disks, Uncoated, 380 V to 1000 V Leaded Dik, Uncoated, 38 V to V B97** B 7 B 774 Application Overcurrent and hort-circuit protection Feature Lead-free terminal Manufacturer logo, date code and type deignation tamped on in black UL approval

Mehr

The following products presented in this data sheet are being withdrawn. B66305F0000X142 B66305F0000X

The following products presented in this data sheet are being withdrawn. B66305F0000X142 B66305F0000X E/ELP Cores Series/Type: E 13/7/4 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B66305F0000X142

Mehr

The following products presented in this data sheet are being withdrawn.

The following products presented in this data sheet are being withdrawn. RM Cores Series/Type: RM 10 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B65814N1011D001

Mehr

B45192, B Tantalum Chip Capacitors Low Profile, H max = 1,5 mm; Standard and Low ESR

B45192, B Tantalum Chip Capacitors Low Profile, H max = 1,5 mm; Standard and Low ESR New series Construction Polar tantalum capacitors with solid electrolyte Flame-retardant plastic case (UL 94 V-0) Optionally tinned or gold-plated terminals Maximum height 1,5 mm Features High volumetric

Mehr

PM/P/P Cores Halves/EP/TT/PR Cores

PM/P/P Cores Halves/EP/TT/PR Cores PM/P/P Cores Halves/EP/TT/PR Cores Series/Type: P 36 x 22 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders

Mehr

B45194, B Tantalum Chip Capacitors Low Profile, H max = 2 mm; Standard and Low ESR

B45194, B Tantalum Chip Capacitors Low Profile, H max = 2 mm; Standard and Low ESR New series Construction Polar tantalum capacitors with solid electrolyte Flame-retardant plastic case (UL 94 V-0) Optionally tinned or gold-plated terminals Maximum height 2,0 mm Features High volumetric

Mehr

Capacitors with Screw Terminals

Capacitors with Screw Terminals Capacitors with Screw Terminals 105 C B 41 560, B 41 580 LL grade Compact low-voltage type For professional power supplies Construction Charge-discharge proof, polar luminum case with insulating sleeve

Mehr

PM/P/P Cores Halves/EP/TT/PR Cores

PM/P/P Cores Halves/EP/TT/PR Cores PM/P/P Cores Halves/EP/TT/PR Cores Series/Type: P 14 x 8 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders

Mehr

Switching Applications PTC Thermistors in Plastic Case, 63 V to 220 V

Switching Applications PTC Thermistors in Plastic Case, 63 V to 220 V Switching Application PTC Thermitor in Platic Cae, 63 V to 22 V J 28... J 29 Application Delayed witching of load For frequent witching 6,3 max. 6,3 max. Feature Encaed thermitor dik with clamp contact

Mehr

The following products presented in this data sheet are being withdrawn. B66414B6008T002 2003-08-08 2004-02-29 2004-08-31

The following products presented in this data sheet are being withdrawn. B66414B6008T002 2003-08-08 2004-02-29 2004-08-31 EFD/EV/DE Cores Series/Type: EFD /8/ The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B66B6008T002

Mehr

B45196-H, B45198-H. Tantalum Chip Capacitors HighCap

B45196-H, B45198-H. Tantalum Chip Capacitors HighCap Construction Polar tantalum capacitors with solid electrolyte Flame-retardant plastic case (UL 94 V-0) Optionally tinned or gold-plated terminals Features Ultra-high volumetric efficiency Excellent solderability

Mehr

Ferrites and Accessories

Ferrites and Accessories Ferrites and Accessories Series/Type: RM 4 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments

Mehr

SMD Varistors MLV; Telecom Series

SMD Varistors MLV; Telecom Series ML; Telecom Series Construction Multilayer technology Termination: nickel barrier (CT series) or silver palladium (CN series) No plastic or epoxy encapsulation assures better than UL 94-0 flaability rating

Mehr

PM/P/P Cores Halves/EP/TT/PR Cores

PM/P/P Cores Halves/EP/TT/PR Cores PM/P/P Cores Halves/EP/TT/PR Cores Series/Type: P 18 x 11 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders

Mehr

Dickfilm-Widerstände Thick-Film Resistors

Dickfilm-Widerstände Thick-Film Resistors Dickfilm-Widerstände Thick-Film Resistors Dickfilm-Widerstände werden universell eingesetzt: in der Uhrenindustrie, Kommunikations-/Datentechnik,... bis hin zur Kfz-Elektronik. Verwendung finden die Baugrößen

Mehr

The following products presented in this data sheet are being withdrawn.

The following products presented in this data sheet are being withdrawn. RM Cores Series/Type: RM The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B80C0000R0 B80C0000R048

Mehr

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 2100A, C2

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 2100A, C2 3 x 528 V + Neutral-Line, 7 to 2100A, C2 Application and performance characteristics EMI Improvement of drive system: Enables conformity of the drive system to EN 55011, to IEC 61800-3 Preferred for use

Mehr

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 630 A, C2

3 Phase + Neutral Line Filter 4F480-xxx x 528 V + Neutral-Line, 7 to 630 A, C2 Application and performance characteristics EMI Improvement of drive system: Enables conformity of the drive system to EN 55011, to IEC 61800-3 Preferred for use with long motor cables Typically C2 limits

Mehr

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1)

bis 2000 m mit 1% Leistungsreduz. pro 100 m up to 2000 m 1% derating per 100 m Normen / Standards IEC (2006-5), UL 508 1) Kundenspezifische, unterbaufähige Netzdrosseln für Siemens-Umrichter der Serien SINAMICS GC und G mit Leistungsmodul PM240-2 (Standard-Variante). Die Drosseln sind seitlich ohne Abstand anreihbar. Line

Mehr

3 Phase Filter 3F690-xxx x 690V, 10 to 400 A, C2

3 Phase Filter 3F690-xxx x 690V, 10 to 400 A, C2 3 x 690V, 10 to 400 A, C2 he filter design and the used materials comply with the requirements of UL 508 and IC 60939. ypische Anwendungen ie Netzfilter der aureihe 3690-xxx.230 sind für die ntstörung

Mehr

Allgemeine Technische Daten / General Technical Data

Allgemeine Technische Daten / General Technical Data Strom / Current [A] Strom / Current [A] Unterbaufähige Motordrosseln für hohe Kabellängen. Geeignet für Siemens-Umrichter der Serien SINAMICS G120C und G120 mit Leistungsmodul PM240-2 (Standard-Variante).

Mehr

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters

2F1000-xxx to 350 A, DC-EMV-Filter / DC EMI Filters Application and performance characteristics Typically used to comply with EMC emission standards Reduce conducted emissions over the frequency range 150 khz to 30 MHz Suitable for Industrial, Railway,

Mehr

ABB i-bus EIB. EIB Power Supply Units

ABB i-bus EIB. EIB Power Supply Units ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!

Mehr

Sine-Filter 3AFS400-xxx 3 x 500 V, 2,5 to 1000 A, 1,5 to 18 khz

Sine-Filter 3AFS400-xxx 3 x 500 V, 2,5 to 1000 A, 1,5 to 18 khz Application and performance characteristics Improvement of drive system: Increases the applicable motor cable length Reduction of motor noise Protects and increases engine life time by: limination of voltage

Mehr

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x T E C H N I S C H E I N F O R M AT I O N Diese Technische Information ergänzt die Betriebsanleitungen der Barcodescanner-Familie CLV6xx mit Angaben zur UL60950-Zertifizierung. Betriebsanleitung CLV62x

Mehr

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Anlage zur Akkreditierungsurkunde D-PL-11055-09-00 nach DIN EN ISO/IEC 17025:2005 Gültigkeitsdauer: 09.02.27 bis 18.10.2020 Ausstellungsdatum: 09.02.27 Urkundeninhaber:

Mehr

asled3000 Dimmbarer High Power LED-Treiber

asled3000 Dimmbarer High Power LED-Treiber asled3000 Dimmbarer High Power LED-Treiber A1.20 01/07 Leistungsmerkmale asled3000 ist ein dimmbares Treibermodul zur Versorgung von Hochleistungs-LEDs beliebiger Lichtfarbe. Es kann bis zu 6 LEDs mit

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Applicant: Product: Certificate of conformity Generating unit, NS-protection Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS

Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS Typennummer I0FAE3xxF100XxxxxS RFI Filter I0FAE4xxF100XxxxxS Filter Typ 3~ RFI Filter I0FAExxxF100DxxxxS Technische Daten Typ E355F E375F E411F 100D... 100D... 100D... Bemessungsstrom [A] 120.0 / 105.0

Mehr

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH nach DIN EN ISO/IEC 17025:2005 Gültigkeitsdauer: 09.02.2017 bis 18.10.2020 Ausstellungsdatum: 09.02.2017 Urkundeninhaber: PEHLA - Gesellschaft für elektrische Hochleistungsprüfungen

Mehr

VDE Prüf- und Zertifizierungsinstitut Gutachten mit Fertigungsüberwachung

VDE Prüf- und Zertifizierungsinstitut Gutachten mit Fertigungsüberwachung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des Gutachtens mit Fertigungsüberwachung Nr.. surveillance No.. USV-Zubehör UPS-Accessories Typ(en) / Type(s): A) PDM35xxIEC-yyy B) PDM13xxIEC-yyy

Mehr

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.

Mehr

Stahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting

Stahlgitterwiderstandselemente. Steel Grid Resistor Elements RSW 1 RSW 54. RSW 1 to RSW W für Einbau. 500 W for fitting Stahlgitterwiderstandselemente Steel Grid Resistor lements 500 W für inbau 500 W for fitting Stahlgitterwiderstandselemente RSW RSW 54 500 W für inbau Steel Grid Resistor lements RSW to RSW 54 500 W for

Mehr

Linn-Pumpen GmbH. Gewerbering 15 D Schalksmühle Telefon: +49 (0) Telefax: +49 (0)

Linn-Pumpen GmbH. Gewerbering 15 D Schalksmühle Telefon: +49 (0) Telefax: +49 (0) inn-n GmbH GS Unterwassermotorpumpen für 4" - Tiefbrunnen GS Submersible s for 4 Wells Anwendungsbereiche - Wasserversorgungsanlagen - Beregnungsanlagen - Druckerhöhungsanlagen - Feuerlöschanlagen Technische

Mehr

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs 2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with

Mehr

Montageanleitung / Mounting instruction / Manuel de montage. D: Abmessung bis zur Klemme. Mat. Nr Typennummer

Montageanleitung / Mounting instruction / Manuel de montage. D: Abmessung bis zur Klemme. Mat. Nr Typennummer Typennummer RFI Filter I0FAE3xxF100XxxxxS Filter Typ 3~ RFI Filter I0FAE3xxF100XxxxxS Technische Daten Typ E330F E337F E345F 100D 100D 100D Bemessungsstrom [A] 55.00/45.70 69.00/57.00 100.00/86.00 Ableitstrom

Mehr

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE 100.000 h geeignet für Zone 2 Ex + 100,000 h suitable for zone 2 hazardous areas + + Für Netz- und Batteriebetrieb For mains and battery supply Lädt und überwacht die Batterie Integrated battery management

Mehr

HEAG 151, 152, 153, 154 Digital Converter

HEAG 151, 152, 153, 154 Digital Converter Montage- und Betriebsanleitung Installation and operating instructions MB095-11055704 Baumer_HEAG151-152-153-154_II_DE-EN (16A1) HEAG 151, 152, 153, 154 Digital Converter 1-2 Allgemeine Hinweise - Funktionsweise

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Certificate of conformity Generating unit, NS-protection Applicant: Product: Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm Ultrakompakt 87 x 54 x 26 mm + Ultra compact 87 x 54 x 26 mm + + Bis zu 57 W oder 2 x 27 W Up to 57 W or 2 x 27 W Einzigartig klein Unique small size Der Klassiker The classic Darf es ein bisschen mehr

Mehr

1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid. Generic specification: IEC , IEC

1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid. Generic specification: IEC , IEC ELCRIGID SN 39 225 E with tin soaked braid Seite 1 v 6 1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid 2 Specifications Generic specification: IEC 61196-1, IEC 60096-0-1

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. bwasserpumpe Sanitary pump Typ(en) / Type(s) a) GENIX

Mehr

Motorenreihe Einphasen Wechselstrom

Motorenreihe Einphasen Wechselstrom Einphasen Wechselstrommotorensingle phase motors enreihe Einphasen Wechselstrom line single-phase Eckdaten Key data n s Gehäusematerial Frame material Number of poles Leistung Output 63 bis 100 63 to 100

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with 1 of the. Schaltschrank-Heizelement Switch cabinet heating element mit Lüfter with

Mehr

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W Kraftvoll bis 200 W + Powerful up to 200 W + + Kleine Bauform Small size Betriebsanzeige über LED und Meldekontakt Status LED and signal contact Zuverlässig entkeimen. Reliable desinfection. Linear V UV

Mehr

With your design proposals or our available simulation and calculation programs, our R&D department realizes and delivers quick solutions.

With your design proposals or our available simulation and calculation programs, our R&D department realizes and delivers quick solutions. HAHN offers solutions for product developers of switching power supplies. In response to the variety of designs which are available on the market, HAHN combines demands and wishes of the developers to

Mehr

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719 Fire and explosion hazard ATEX 137 1999/92/EG und ATEX 95 2014/34/EU Danger assessment and determination of explosion protection zone for the test space as well as the installation site ATEX-Check list

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Netzgerät für IT-Geräte Power supply for IT-Equipment

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GKu - Datenblätter GKu - Datasheets AG - CH-40 Andelfingen - Tel. +41 (0)2 30 2 2 - info@islikermagnete.ch - www.islikermagnete.ch GKu GKu Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions

Mehr

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC AC-RIDER 80VA WWW.AC-RIDER.COM TÜV Rheinland geprüfte Sicherheit Besondere Merkmale Features 12 VDC Eingang 12 VDC input Hoher Wirkungsgrad High efficiency Überlast / Kurzschlußfest Overload / Short-circuit

Mehr

EMV-Bauelemente EMC Components

EMV-Bauelemente EMC Components EMV-Bauelemente EMC Components SIMIDs werden für die nieder- und hochfrequente Entkopplung von Signal- und Steuerkreisen sowie zum Aufbau von Schwingkreisen eingesetzt. Typische Anwendungsgebiete sind:

Mehr

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Netzgerät für IT-Geräte Power supply for IT-Equipment

Mehr

VEKA. Air handling units. Lüftungsgeräte. Air handling units

VEKA. Air handling units. Lüftungsgeräte. Air handling units Lüftungsgeräte Niedriges Geräuschniveau Ventilator mit Geschwindigkeitsregelung (Spannungsänderung) Elektrische oder Wasser-Erwärmungseinrichtung Leicht abnehmbarer Deckel für Wartung Filterkasten mit

Mehr

Datenblatt. P-series PDU 2.5/4/4AN

Datenblatt. P-series PDU 2.5/4/4AN Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means

Mehr

IDG. Drehzahlsensor / Speed Sensor

IDG. Drehzahlsensor / Speed Sensor Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor

Mehr

APPLICATION GUIDELINE

APPLICATION GUIDELINE PROCESS AUTOMATION APPLICATION GUIDELINE EN DE APPLICATION GUIDELINE WANDFLUH SOLENOID VALVE PEPPERL+FUCHS SOLENOID DRIVER ANWENDUNGSBESCHREIBUNG MANGETVENTIL WANDFLUH VENTILSTEUERBAUSTEIN PEPPERL+FUCHS

Mehr

Korrektur. Mechatronisches Antriebssystem MOVIGEAR -DBC-B, -DAC-B, -DSC-B, -SNI-B, * _0315*

Korrektur. Mechatronisches Antriebssystem MOVIGEAR -DBC-B, -DAC-B, -DSC-B, -SNI-B, * _0315* Antriebstechnik \ Antriebsautomatisierung \ Systemintegration \ Services *21931577_0315* Korrektur Mechatronisches Antriebssystem MOVIGEAR -DBC-B, -DAC-B, -DSC-B, -SNI-B, Ausgabe 03/2015 21931577/DE SEW-EURODRIVE

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle Power converter for

Mehr

SPINNER MOBILE COMMUNICATION

SPINNER MOBILE COMMUNICATION KOAXIALE ABSCHLUSSWIDERSTÄNDE & DÄMPFUNGSGLIEDER COAXIAL LOADS & ATTENUATORS Abschlusswiderstände übernehmen häufig die Funktion einer Antenne während der Test- oder Einmessphase einer Mobilfunk-Basisstation.

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with page 1 of the. Steckdose Socket-outlet Typ(en) / Type(s): 6211..EMS Si/I

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Terrestrische Photovoltaik-Module mit Silizium-Solarzellen

Mehr

Control shut-off butterfly valves DN 50 DN 400 PN

Control shut-off butterfly valves DN 50 DN 400 PN Features Applications include HEVAC and drinking water systems, sanitary and industrial plants for control or shut-off of water and steam -10...+110 C Leakage rate: tight sealing Control and shut-off butterfly

Mehr

"Low Cost" Linear-Speicherdrosseln Speicherenergie ½ L I² 0,5mWs, 0,75mWs, 1,5mWs und 2,5mWs

Low Cost Linear-Speicherdrosseln Speicherenergie ½ L I² 0,5mWs, 0,75mWs, 1,5mWs und 2,5mWs "ow Cost" inear-speicherdrosseln Speicherenergie ½ I² 0,mWs, 0,7mWs, 1,mWs und 2,mWs "ow Cost" inear Storage-Chokes Storage capacity ½ I² 0,mWs, 0,7mWs, 1,mWs and 2,mWs Für moderne Stromversorgungen müssen

Mehr

312LR, 412LR Series Max. Ripple, Extra Long Life > h / 105 C Snap-In

312LR, 412LR Series Max. Ripple, Extra Long Life > h / 105 C Snap-In Anwendungen und Merkmale / Applications and Features Professionelle Stromversorgungen Professional power supplies Servoantriebe und Solarumrichter Servo drives and solar inverters Höchste Wechselstrombelastbarkeit

Mehr

Datenblatt / Data sheet

Datenblatt / Data sheet Seite/Page 1/5 Abbildungen / Illustration Maßzeichnung / Dimensions Produktbeschreibung Product specification Kompaktes, steckbares Relais für den industriellen Einsatz. Compact, pluggable relay for industrial

Mehr

Electrical testing of Bosch common rail Injectors

Electrical testing of Bosch common rail Injectors Electrical testing of Bosch common rail Injectors Contents: 1. Adapter cable for Hybridtester FSA 050 (article number 0 684 010 050 / 1 687 023 571) 2. Electrical testing of Bosch common rail solenoid

Mehr

Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen

Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen 15 00 V! Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen Pronutec offers his Fuse bases for DC installations up to 1500 V: the 1P NH type Fuse bases with

Mehr

ORION three-phase 2-250kVA

ORION three-phase 2-250kVA ORION three-phase 2-250kVA Orion stabilizers are available for different ranges of input voltage fluctuation. Standard models offer a double input connection so that with the same unit two different input

Mehr

Umrichter. Bremschopper Bremswiderstand. Benefits: compact construction low temperature rise connection on terminals or wire at option low noise

Umrichter. Bremschopper Bremswiderstand. Benefits: compact construction low temperature rise connection on terminals or wire at option low noise Dreiphasen-Netzdrosseln 1%uk (3 eiter) (3 A-160 A) Three-phases ine chokes 1%uk (3 lines) (3 A-160 A) aureihe CNW 900 Selfs de réseau triphasées 1%uk (3 conducteurs) (3 A-160 A) Type CNW 906/... - Anwendungen:

Mehr