Test Report. No of Airborne Sound Insulation in Laboratory, All-Glass Sliding System. Make SUNFLEX, Type SF 20

Test Report. No of Airborne Sound Insulation of folding sliding system SF 55 in Laboratory

Prüfbericht-Nummer: 153/45

Test Report. No of Airborne Sound Insulation in Laboratory, Horizontal-Sliding-Wall-System SF 50 H-S-W

Test Report. No dated 29 th January Airborne Sound Insulation of Folding-Sliding-System SF 75H in Laboratory

Prüfbericht Nr. / Test Report No: F (Edition 1)

Kalibrier-Zertifikat Calibration certificate *

Ventilatormessung / fan measurement

Report Number of issued No. copies Pages date. MHM-EST /D Jakobi. Object under test Type designation Identification No.

Messung der Luftschalldämmung nach ISO Messung der Luftschalldämmung von Bauteilen im Prüfstand

Calibration Certificate

Calibration Certificate

Test Report. Test of resitance to inertia effects of Zirkona Backwall. Sled Test (Frontal Impact) 20 g / 30 ms

Calibration Certificate

Calibration Certificate

Test Report No.: Prüfbericht - Nr.: Client: Auftraggeber:

Wissen schafft Fortschritt

Shock pulse measurement principle

Newest Generation of the BS2 Corrosion/Warning and Measurement System

WERKSKALIBRIERSCHEIN FACTORY CALIBRATION CERTIFICATE

Silent Gliss. Colorama 1. Acoustic Certificate Zertifikat Akustik

Prüfzeugnisse Test certificates

SCHRAMM empty switchgear cabinet enclosures are assigned to the EU Directive 2006/95/EC - Low Voltage Directive in terms of their CE marking.

Calibration Certificate with reference to ISO Kalibrierschein in Anlehnung an DIN ISO 10012

Evidence of Performance

Level 1 German, 2012

Anwendungs hinweise Application hints

Measurement of sound absorption coefficient for a Gabriel OKA.DeskTOP-Akustik panel with mounting depth 200 mm

Quadt Kunststoffapparatebau GmbH

UNTERSUCHUNGSBERICHT Nr.: E 4.881

Calibration Certificate

a) Name and draw three typical input signals used in control technique.

Cleanroom Fog Generators Volcano VP 12 + VP 18

OBERFLÄCHENRISS-PROTOKOLL surface crack examination record. Impeller, part 3 Ø 488/290 x 126,5 mm Mustermannstr. 1 D Musterhausen

Protokoll Standardmessung eines PV Einstrahlungssensors

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment

Test report. Bericht Nr.: PH001/10. Gruppe Physik Seite 1 von 6. Liquisol Mr. Tom Huymans Lindberg Oelegem BELGIUM. Client: Order No.

Systemaufbau: System B nach DIN EN 1264 system construction: system B in acc. to DIN EN Giacomini PE-RT/EVOH/PE-RT 16mm x 1.

Kalibrierschein Kalibrierzeichen K

Protokoll Leistungsmessung eines PV Moduls Test Report - Power measurement of a PV module

* Untersuchungsbericht / Investigation Report A

Kalibrierschein Kalibrierzeichen K

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

Protokoll Leistungsmessung eines PV Moduls Test Report - Power measurement of a PV module

Protokoll Leistungsmessung eines PV Moduls Test Report - Power measurement of a PV module

GARMENT SIZING WITH BODY MEASUREMENTS. How to find the right size to order from Jiakina

Kalibrierzeichen Calibration certificate

VDE Prüf- und Zertifizierungsinstitut GmbH / VDE Testing and Certification Institute. VDE Prüfbericht / VDE Test Report

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

Protokoll Standardmessung eines PV Moduls Test Report - Standard measurement of a PV module

Measurement of sound absorption for a Gabriel OKA.DeskTOP-Akustik panel

CABLE TESTER. Manual DN-14003

PELTIER-HOCHLEISTUNGSMODULE

Lufft UMB Sensor Overview

Level 1 German, 2013

Test report number: TC10_119B. ACOUSTIC TEST ON CP 130-LS Ventalis Semco phone 45_34 Ventalis covered REYNAERS ALUMINIUM NV

Inverse Problems In Medical Imaging


WIKA Alexander Wiegand SE & Co. KG. Deutsche Akkreditierungsstelle GmbH. Deutschen Kalibrierdienst. Calibration certificate Kalibrierschein

Platzhalter für Funktions-Garantie- Zeichen. für alle HOPPE Tür- und Fenstergriffe! Export Catalogue 20/202

Snap-in switch for switches PSE, MSM and MCS 30

Level 2 German, 2015

Kalibrierschein Calibration Certificate

Zehnder CLD. Housing for walls, floors and ceilings

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung

Calibration certificate Calibration mark

Kalibrierschein Kalibrierzeichen Calibration Certificate Calibration mark

TEST PROTOCOL [Prüfprotokoll]

Björn Knust Mat.-Nr Hildesheim

Kalibrier-Zertifikat Calibration Certificate

PRODUCT OVERVIEW PRODUKTÜBERSICHT OFFICE Maße / measurements: 200 x 1200 x 4 mm. Forbo Flooring GmbH

Handwerk Trades. Arbeitswelten / Working Environments. Green Technology for the Blue Planet Clean Energy from Solar and Windows

Calibration certificate Calibration mark. Spannungs-, Stromstärke- und Leistungsquelle Voltage-, current- and power source. ST-1021xxxx

AR-16-GF ,3,7,8-TetraCDF

Tara-Wood. Specialize in Manufacture of High Quality Solid Wood Flooring. TARA GROUP OF COMPAINES PRICE LIST - Catalogue

Using TerraSAR-X data for mapping of damages in forests caused by the pine sawfly (Dprion pini) Dr. Klaus MARTIN

Level 1 German, 2016

Test report No VU

Summary Details for Performance, Duration and Acoustic Measurements for the. Aircon 10S Wind Turbine. UK MCS Certification Summary

Milenia Hybridetect. Detection of DNA and Protein

Supplementary material for Who never tells a lie? The following material is provided below, in the following order:

IFM-Institut für Fahrzeugtechnik und Mobilität. Report. No. S Comparison of RDE evaluation software

Device Component: - SIPLUS extreme ET 200MP IM PN ST TX RAIL Order Nr. 6AG2155-5AA00-4AB0. Breslauer Straße Fürth Deutschland

Interconnection Technology

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens

s 120; s 311; s 312; s 330; s 510; s 511; s 530; s 700

OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2.

Sensoren / Sensors XA1000 / XP200 / XP400 XP100 / XP101.

Calibration Services Application Note AN001


Transkript:

Schallschutzprüfstelle VPMA Zertifiziert Güteprüfungen Eignungsprüfungen ABP Staatlich anerkannte Sachverständige für den Schallschutz und Wärmeschutz IK-Bau NRW Blower Door Messungen Gebäudethermografie Energieberatung EnEV-Nachweise Wohngebäude EnEV-Nachweise Nicht-Wohngebäude Geschäftsführer: Dr.-Ing. Lothar Siebel Dipl.-Ing. Bernd Gebing Steuer-Nr. 201/5992/3795 USt.-IdNr. DE123595587 Aachen, 08.01.2014 Test report No.: 1312/661 Measurement of impact sound insulation according to ISO 10140-3 : 2010-12 Laboratory measurement of sound insulation of building elements. Product name: Signature Confort+ Applicant: BALSAN Moquette Corbilly D14 F-36330 ARTHON Number of pages: 5 pages and 1 supplement Büros: Charlottenburger Allee 41, 52068 Aachen Labor: Hauptstr. 133, 52474 Alsdorf Tel. +49(0)241/970220 Fax +49(0)241/572956 info@swagmbh.de www.swagmbh.de Handelsregister Amtsgericht Aachen HRB 2708 Sparkasse Aachen BLZ 390 500 00 Konto 110 111 94 IBAN DE 03 3905 00 00 00 11 194 BIC(Swift) AA CS DE 33

1 Test Measurement of impact sound insulation according to ISO 10140-3 : 2010-12 Laboratory measurement of sound insulation of building elements. 1.1 Product name Signature Confort+ 1.2 Test object, category and assembly Sample taking by: Installed by: applicant employees of SWA GmbH x Test object / Floor covering Category according to ISO 10140 resilient floor covering textile floor covering solid floor covering on an impact sound insulation / separating layer screed on an impact sound insulation / separating layer I II x Installation type loose laid glued 1.3 Construction (from top to bottom) Thickness: Material: Area-related mass 8,5 mm ³ Signature Confort+ 2,10 kg/m² ³ Total thickness of example: 8,5 mm Area-related mass of example: 2,10 kg/m² ² area-related mass determined by employees of SWA GmbH ³ information of applicant page 2 of 5

1.4 Measurement execution Measurement of impact sound level: Reverberation period measurement: with 5 fixed microphone positions by 2 tapping machine positions each (The third octave single results were energetically averaged) with 5 fixed microphone positions by 2 loud speaker positions each (The third octave single results were energetically averaged) Corrections: not any - background noise corrections irrelevant - airborne noise corrections irrelevant 1.5 Annotations - Damages caused by tapping machine influences could not be determined on the example. 1.6 Test stand description Test rooms: Laboratory of SWA GmbH Sending room: Receiving room: 4,29 m x 4,51 m x 2,76 m; V = 53,40 m³ (with diffusers) 4,29 m x 4,51 m x 3,05 m; V = 59,01 m³ (with diffusers) Reference floor: 4,29 m x 4,51 m; S = 19,35 m² 14 cm solid concrete floor with an area-related mass m 322 kg/m² Flanking walls: lime sand brick walls without light weighting facing shells with a medium area-related mass of m 330 kg/m² 1.7 Measuring systems Real time analyzer: CESVA INSTRUMENTS, TYP: SC310, SN: T234359* Microphone: CESVA INSTRUMENTS, TYP: C130, SN: 11861* Microphone amplifier: CESVA INSTRUMENTS, TYP: PA13, SN: 49649* Calibrating device: CESVA INSTRUMENTS, TYP: CB006, SN 49649* Loudspeaker: Dodecahedron, CESVA INSTRUMENTS* Tapping machine: NORSONIC, type 211, SN: 502* (tapping machine with 3 feeds and 5 hammers according to ISO 10140) *) last examination by PTB (Physikalisch-Technische Bundesanstalt, Brunswick, Germany) in Feb. 2013 page 3 of 5

2 Analysis The impact sound levels generated by the standardized tapping machine are measured in the receiving room under a solid concrete floor without and with a floor covering. From the measured values the measurement of impact sound insulation is calculated as follows: ΔL = L n,0 - L n in db L n,0 = Impact sound level without floor covering in db L n = Impact sound level with floor covering in db To determine the weighted impact sound reduction the applicable reference curve is shifted in 1 db steps into the mess curve so that the sum of the most unfavorable deviations correspondents as close as possible to the value of 32 db without exceeding this value. The linear impact sound level ΔL lin of importance and you can calculate after the following equation: ( ) the calculated weighted norm impact sound level of the cover blanket with the blanket edition to be checked is. 78 db, investigates to 4.3.1 DIN EN ISO 717-2 : 2013. Spectrum customization value. Spectrum customization value. 2.1 Applied standards Standard: (Issue)* Title DIN EN ISO 10140-1:2010-12 Akustik Messung der Schalldämmung von Bauteilen im Prüfstand Teil 1: Anwendungsregeln für bestimmte Produkte DIN EN ISO 10140-3:2010-12 Akustik Messung der Schalldämmung von Bauteilen im Prüfstand Teil 3: Messung der Trittschalldämmung DIN EN ISO 10140-4:2010-12 Akustik Messung der Schalldämmung von Bauteilen im Prüfstand Teil 4: Messverfahren und Anforderungen DIN EN ISO 10140-5:2010-12 Akustik Messung der Schalldämmung von Bauteilen im Prüfstand Teil 5: Anforderungen an Prüfstände und Prüfeinrichtungen DIN EN ISO 717-2:2013-06 Akustik Bewertung der Schalldämmung in Gebäuden und von Bauteilen Teil 2: Trittschalldämmung * German issue. page 4 of 5

3 Test Results 3.1 Reference floor Weighted standard impact sound level of the reference floor: L n,0,w : 74 db C l,0 : -11 db 3.2 Floor covering ΔL w = 30 db ΔL lin = 18 db C l,δ = -12 db C l,r = 1 db C l,r,50-2500 = 5 db The results are based on tests, which were effected with on artifical source of sound under laboratory conditions. (standard procedure); compare measuring results in supplement 1 of this report. (Dr.-Ing. A. Siebel) page 5 of 5

Test results Supplement 1 Measurement of impact sound insulation according to ISO 10140-3 : 2010-12 Laboratory measurement of sound insulation of building elements. Product name: Signature Confort+ Category: I according to ISO 10140 Construktion: 8,5 mm Signature Confort+ (from top to bottom) 2,10 kg/m² Reference floor: installed by: solid concrete floor applicant Date of test: 13.12.2013 annotations: - climate in the source room in the receiving room air temperature: 19 C 19 C humidity: 56% 60% Frequency L n,0 ΔL f third-octave third-octave [Hz] [db] [db] 50 56,5 6,9 63 62,7 4,4 80 57,4 5,5 100 57,2 7,0 125 67,5 8,0 160 62,6 11,2 200 64,1 15,9 250 67,1 20,1 315 65,3 24,5 400 64,7 30,0 500 65 33,1 630 65,3 37,3 800 66,4 43,7 1000 67,8 51,0 1250 67,7 53,4 1600 68,2 54,2 2000 68,8 55,0 2500 68,6 59,5 3150 67,9 58,1 4000 66,9 56,5 5000 64,4 53,5 *Airborne noise correction for the measured value Calculation according to ISO 717-2:2013-06 ΔL w = 30 db ΔL in = 18 db Impact sound reduction ΔL in db 60,0 50,0 40,0 30,0 20,0 10,0 0,0 63 125 250 500 1000 2000 4000 Frequency f in Hz C l,δ = -12 db C l,r = 1 db C l,r,50-2500 = 5 db The results are based on tests, which were effected with on artifical source of sound under laboratory conditions. (standard procedure) Test report no.: 1312/661 SWA Schall- und Wärmemessstelle Aachen GmbH Aachen, 08.01.2014 (Dr.-Ing. A. Siebel)