myavr my7-segment Add-On 1.0 Technische Beschreibung technical description

Ähnliche Dokumente
myavr GraficLCD 1.00 Technische Beschreibung technical description

myavr myavr Board light Version 1.01 Technische Beschreibung technical description

myavr myavr Board USB 2.06 Technische Beschreibung technical description

myavr USB-RS232-Bridge Projektbeschreibung Project description

myavr myavr LCD Add-On 2.5 Technische Beschreibung technical description

myavr myavr Jingle Bells Anwendungsbeispiel / Application Note Jingle Bells am mysmartcontrol Jingle Bells on mysmartcontrol

myavr myavr Board LPT 1.52 Technische Beschreibung technical description

myavr myavr Würfelspiel Anwendungsbeispiel / Application Note Würfelspiel am mysmartcontrol Dice on mysmartcontrol

myavr mysmartlab (Oszilloskop & Logic Analyzer) Hardwareversion 1.07 Softwareversion 1.0 Technische Beschreibung technical description

myavr myavr Board light Version 1.03 Bauanleitung Assembly instruction

myavr USB-SP12-Programmer Projektbeschreibung Project description

myavr mymultiprog 1.06 Technische Beschreibung technical description

myavr myavr Board light Version 1.03 Bauanleitung Assembly instruction

USB-Parallel- Adapter Projektbeschreibung zum USB-Parallel-Adapter für das mysmartusb Board

myavr myavr Board LPT 1.52 Bauanleitung assembly instruction

Release Notes BRICKware Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0

User Manual Bedienungsanleitung. snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter. English. Deutsch

Das 1x1 für kleine Fotografen

myavr myavr unter Linux Anwendungsbeispiel / Application Note myavr unter Linux myavr with Linux

Benutzer- und Referenzhandbuch

150 ma (bei eingeschalteter Hintergrundbeleuchtung)

ACDEFG. Hotmetal Borders

BA63 Zeichensätze/ Character sets

myavr Board 2.0 USB Bauanleitung

myavr mymultiprog MK Technische Beschreibung technical description

Tube Analyzer LogViewer 2.3

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016

Benutzer- und Referenzhandbuch

The projectivity of the moduli space of stable curves. I: Preliminaries on "det"...

Electrical testing of Bosch common rail piezo injectors

myavr myavr Stamp myavr Stamp 64 myavr Stamp 64 PLUS myavr Stamp 256 myavr Stamp 256 PLUS

Dreiphasenumsteller Typ KDV Threephase Tap Changer Type KDV

SnagIt LiveJournal Output By TechSmith Corporation

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

Tabellen & Diagramme mit Excel

SnagIt Movable Type Output By TechSmith Corporation

Wie Programm Neighborhood Agent mit Secure Gateway konfigurieren. von Stefan Müri

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

ISBN (Print); (PDF), (epub) Bibliografische Information der Deutschen Nationalbibliothek

E/A-Bedieneinheit. I/O Control unit DE/GB 08/02

CABLE TESTER. Manual DN-14003

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten.

Galileo Desktop Benutzerhandbuch Version 1.02

Cloud for Customer Learning Resources. Customer

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens

PS3 / PS4 / PC XBOX 360 GAMING HEADSET LX16

Das eigene Web mit HTML, CSS und JavaScript

MindestanforderungenanDokumentationvon Lieferanten

HEAG 151, 152, 153, 154 Digital Converter

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions

Montageanleitung Installation Manual

Thrust Series Catalogue

Diese Produktinformation enthält neueste Informationen bzw. ergänzt die Angaben im Getting Started und im elektronischen Handbuch.

Wirtschaftsstandort. Augsburg. Dr. Marcus Cieleback, Group Head of Research, PATRIZIA Immobilien AG. 27. Juni PATRIZIA Immobilien AG

GAMING HEADSET LX16 PRO

Montageanweisung Mounting Instructions NGC NGC NGC

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Unit 4. The Extension Principle. Fuzzy Logic I 123

2009 APIS IT GmbH IQ-Basiswissen

Konkret - der Ratgeber: Die besten Tipps zu Internet, Handy und Co. (German Edition)

TomTom WEBFLEET Tachograph

Ein Stern in dunkler Nacht Die schoensten Weihnachtsgeschichten. Click here if your download doesn"t start automatically

Level 2 German, 2015

CA_MESSAGES_ORS_HDTV_IRD_GUIDELINE

Parameter-Updatesoftware PF-12 Plus

How-To-Do. Communication to Siemens OPC Server via Ethernet

Meeting and TASK TOOL. Bedienungsanleitung / Manual IQxperts GmbH. Alle Rechte vorbehalten.

Walter Buchmayr Ges.m.b.H.

com.tom PORTAL Registrierung

DMS für besondere Anwendungen - Hochtemperatur-DMS

R&R. Ges. für Rationalisierung und Rechentechnik mbh. R&R RR-P-508 / ST106-EX1 motor-control unit

Gamperl & Hatlapa GmbH Modem/WiFi settings

Electromagnetic Flowmeter FXE4000-DE43F

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

Finite Difference Method (FDM)

Produktdatenblatt. Artikel Nr.: Wand- / Deckenleuchte, LED Panel RGB, Weiß, 24V DC, 36,00 W, RGB. Technische Daten.

Standard: ÖVE/ÖNORM E Filler/Tape

Guidance Notes for the eservice 'Marketing Authorisation & Lifecycle Management of Medicines' Contents

Table of Contents. Table of Contents Building management systems Industrial wiring installation EST 4 Programmable miniature control systems (24V)

UWC 8801 / 8802 / 8803

Disclaimer SAP SE or an SAP affiliate company. All rights reserved. Public

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.

Outdoor-Tasche. Operating Instructions Bedienungsanleitung GB D

Impressum. link StandortID=0&Suchbegriff=kaspar+wohlleb. Kontakt: Registereintrag: Aufsichtsbehörde:

PONS DIE DREI??? FRAGEZEICHEN, ARCTIC ADVENTURE: ENGLISCH LERNEN MIT JUSTUS, PETER UND BOB

s 120; s 311; s 312; s 330; s 510; s 511; s 530; s 700

Datenschutzerklärung. Published: Author: 42media services GmbH

Level 2 German, 2013

IncaMail. copyright Swisssalary Ltd w w w.sw isssalary.ch. Datum: Weitere Informationen:

Martin Luther. Click here if your download doesn"t start automatically

OPTOELEKTRONIK Vertriebs GmbH

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Aviar, Weiß-satiniert, V AC/50-60Hz, 40,00 W. Technische Daten.

SAMPLE EXAMINATION BOOKLET

A Verstärker-Option / A Amplifier Kit

VoIP Test mit HST-3000 und T-Online Anschluss Von Sascha Chwalek

J RG IMMENDORFF STANDORT F R KRITIK MALEREI UND INSPIRATION ERSCHEINT ZUR AUSSTELLUNG IM MUSEUM LU

SIMATIC Industrie-PC IPC477D PRO Produktinformation

Where are we now? The administration building M 3. Voransicht

Transkript:

myavr Technische Beschreibung technical description my7-segment Add-On 1.0 Inhalt Allgemeine Beschreibung... 3 Eigenschaften... 3 Technische Daten... 4 Betriebsdaten... 4 Mechanische Daten... 4 Schaltplan... 4 Pinbelegung... 4 Bestückungsplan... 5 Bestücktes Board... 5 Ansteuerung... 6 Anwendungsbeispiel... 7 Allgemeine Sicherheitshinweise... 7 Contents General description... 3 Properties... 3 Technical Data... 4 Operating Data... 4 Mechanical Data... 4 Circuit diagram... 4 Pinlayout... 4 Layout diagram... 5 Board, equipped... 5 Programming... 6 Example of use... 7 Safety Guidelines... 7 www.myavr.de Laser & Co. Solutions GmbH 05/2010 www.myavr.com

Seite: 2/7 Technische Beschreibung my7-segment Add-On 1.0 Die Informationen in diesem Produkt werden ohne Rücksicht auf einen eventuellen Patentschutz veröffentlicht. Warennamen werden ohne Gewährleistung der freien Verwendbarkeit benutzt. Bei der Zusammenstellung von Texten und Abbildungen wurde mit größter Sorgfalt vorgegangen. Trotzdem können Fehler nicht vollständig ausgeschlossen werden. Die Autoren können für fehlerhafte Angaben und deren Folgen weder eine juristische Verantwortung noch irgendeine Haftung übernehmen. Für Verbesserungsvorschläge und Hinweise auf Fehler sind die Autoren dankbar. Alle Rechte vorbehalten, auch die der fotomechanischen Wiedergabe und der Speicherung in elektronischen Medien. Die gewerbliche Nutzung der in diesem Produkt gezeigten Modelle und Arbeiten ist nicht zulässig. Fast alle Hardware- und Softwarebezeichnungen, die in diesem Dokument erwähnt werden, sind gleichzeitig auch eingetragene Warenzeichen und sollten als solche betrachtet werden. Laser & Co. Solutions GmbH Promenadenring 8 02708 Löbau Deutschland www.myavr.de In spite of the great care taken while writing this document the author is not responsible for the topicality, correctness, completeness or quality of the information provided. Liability claims regarding damage caused by the use of any information provided, including any kind of information which is incomplete or incorrect,will therefore be rejected. All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. All trademarks and registered trademarks appearing in this document are the property of their respective owners. Laser & Co. Solutions GmbH Promenadenring 8 02708 Löbau Germany www.myavr.com Tel: ++49 (0) 358 470 222 Fax: ++49 (0) 358 470 233 Tel: ++49 (0) 358 470 222 Fax: ++49 (0) 358 470 233

Technische Beschreibung my7-segment Add-On 1.0 Seite: 3/7 Allgemeine Beschreibung Das my7-segment Add-On ist ein anschlussfertiges Erweiterungsmodul, welches direkt über die standardisierte Steckerleiste mit den myavr Boards verbunden werden kann. Die Ansteuerung kann über ein myavr Board oder über ein mysmartcontrol erfolgen. Die Erweiterung mit zusätzlichen Add-Ons aus der myavr-serie ist möglich. Jede 7-Segment-Anzeige kann jeweils die Ziffern 0-9 darstellen. Es gehören 6 Anzeigen zu diesem Add-On. Es ist robust und auf die myavr-serie abgestimmt. General description The my7-segment add-on is an extension module which you can connect directly with the myavr board via the multi-pin connector. You can activate it via a myavr board or via a mysmartcontrol. You can also expand the module with other add-ons from the myavr series. Every 7-segment display can display the numbers 0-9. This add-on has 6 7-segment displays. It is robust and aligned to the myavr series. Eigenschaften 6x 7-Segment-Anzeige Jede 7-Segment-Anzeige kann die Ziffern 0-9 darstellen Freie Wahl der Verbindungen über die Sockelleisten mittels Patchkabel Segmente sind einzeln ansteuerbar Steckerleiste für den Anschluss an ein myavr Board Buchsenleiste für den Anschluss weiterer Module Leiterplatte gebohrt, verzinnt, Industriefertigung, robust, bedruckt Properties 6x 7-segment display Every 7-segment add-on can display the numbers 0-9 You can activate the segments separately Free choice of connections on the pin header male through patch cable multi-pin connector for the connection with a myavr Board Female connector for the connection with other modules Printed circuit board pre-drilled, tin-plated, industrial production, solid, printed myavr Board-Verbinder myavr Board connector 6x 7-Segment-Anzeige 6x 7-segment display Erweiterungsbuchse add-on-socket

Seite: 4/7 Technische Beschreibung my7-segment Add-On 1.0 Technische Daten Technical Data Betriebsdaten Operating Data Betriebsstrom < 500 ma Operating Current < 500 ma Betriebsspannung 4,5 V - 5,2 V Operating Voltage 4,5 V - 5,2 V Betriebstemperatur 0 C bis 70 C Operating Temperature 0 C to 70 C Lagertemperatur -65 C bis 150 C Storage Temperature -65 C to 150 C Mechanische Daten Mechanical Data Abmessungen Platine Dimensions of the board 90 mm x 60 mm x 1,5 mm (L x B x H) (L X B X H) 90 mm x 60 mm x 1,5 mm Masse ca. 36 g Weight ca. 36 g Rastermaß 2,54 mm Grid dimensions 2,54 mm Leiterplattenmaterial FR4; 0,35 µm Cu PCB material FR4; 0,35 µm Cu Schaltplan Circuit diagram Pinbelegung Pinlayout Pin Nummer / Pin No. Symbol / symbol Name und Funktion / Name and Function 3 LT Funktionstest (LOW-Aktiv) Lamp test input (active LOW) 4 BI Adressdeaktivierung (LOW-Aktiv) Ripple blanking input (active LOW) 5 LĒ Taktfrequenzeingang latch enable inputs 7, 1, 2, 6 D 1 to D 4 BCD Adressierung BCD adress inputs 8 GND Masse (0 V) ground (0 V) 13, 12, 11, 10, 9, 15, 14 16 V CC Q a to Q g Segmentausgabe segmentes outputs Positive Versorgungsspannung positive supply voltage

Technische Beschreibung my7-segment Add-On 1.0 Seite: 5/7 Bestückungsplan Layout diagram Bestücktes Board Board, equipped

- Seite: 6/7 Technische Beschreibung my7-segment Add-On 1.0 Ansteuerung Die Ansteuerung des my7-segment Add-On erfolgt über den BCD-zu-7-Segment-Decoder und den Demultiplexer. Zur Ansteuerung ist es nötig, die Verbindung zwischen der 7-Segment-Anzeige, dem Decoder und Multiplexer herzustellen. Funktionstabelle des 74HC4511 Programming The activation of the my7-segment add-on happens via the BCD-to-7-segment decoder and the demultiplexer. To control it is necessary to make the connection between the 7-segment display, the decoder and multiplexer. Function Table 74HC4511 INPUTS OUTPUTS DISPLAY LE BI LT D 4 D 3 D 2 D 1 Q a Q b Q c Q d Q e Q f Q g X X L X X X X H H H H H H H 8 X L H X X X X L L L L L L L blank L H H L L L L H H H H H H L 0 L H H L L L H L H H L L L L 1 L H H L L H L H H L H H L H 2 L H H L L H H H H H H L L H 3 L H H L H L L L H H L L H H 4 L H H L H L H H L H H L H H 5 L H H L H H L L L H H H H H 6 L H H L H H H H H H L L L L 7 L H H H L L L H H H H H H H 8 L H H H L L H H H H L L H H 9 L H H H L H L L L L L L L L blank L H H H L H H L L L L L L L blank L H H H H L L L L L L L L L blank L H H H H L H L L L L L L L blank L H H H H H L L L L L L L L blank L H H H H H H L L L L L L L blank H H H X X X X (1) (1) 1. Ist abhängig vom verwendeten BCD-Code während der LOW-zu-HIGH Übertragung von LE. L = LOW voltage Level H = HIGH voltage Level X = Don t Care Dem BCD-zu-7-Segment-Decoder übergibt man die Zahl, die man auf der 7-Segment-Anzeige ausgeben möchte. Es ist nur sinnvoll Werte von 0 bis 9 zu übergeben, da die 7-Segment-Anzeige sonst nichts ausgibt. Funktionstabelle des DM74LS138 1. Depends upon the BCD-code applied during the LOW-to- HIGH transition of LE. L = LOW voltage Level H = HIGH voltage Level X = Don t Care You give a number to the BCD-to-7-segment decoder which you want to display on the 7-segment display. It only makes sense to give them values between 0 and 9 because otherwise the 7-segment display shows nothing. Function Table DM74LS138 Inputs Enable Select Outputs G1 G2 (Note 1) C B A Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 X H X X X H H H H H H H H L X X X X H H H H H H H H H L L L L L H H H H H H H H L L L H H L H H H H H H H L L H L H H L H H H H H H L L H H H H H L H H H H H L H L L H H H H L H H H H L H L H H H H H H L H H H L H H L H H H H H H L H H L H H H H H H H H H H L H = HIGH Level L = LOW Level X = Don t Care Note 1: G2 =G2A+G2B Über den Demultiplexer wählt man aus, auf welcher 7-Segment-Anzeige man die Zahl darstellen möchte. Dabei werden die 7-Segment-Anzeigen von vorn gezählt, d.h. die linke 7-Segment-Anzeige hat die Nummer 0. Via the Demultiplexer you can choose on which 7-segment display you want to have the number. The 7- segment displays are counted from the front. That means that the left 7-segment display has the number 0.

Technische Beschreibung my7-segment Add-On 1.0 Seite: 7/7 Anwendungsbeispiel Example of use Abbildung / picture: Zähler mit mysmartcontrol Counter with mysmartcontrol Allgemeine Sicherheitshinweise Grundsätzlich ist my7-segment nur zum Einsatz unter Lern- und Laborbedingungen konzipiert. Er ist nicht vorgesehen und nicht dimensioniert zur Steuerung realer Anlagen. Bei vorschriftsmäßigem Anschluss und Betrieb treten keine lebensgefährlichen Spannungen auf. Beachten Sie trotzdem die Vorschriften, die beim Betrieb elektrischer Geräte und Anlagen Gültigkeit haben. Wir versichern, dass die Leiterplatte durch den Hersteller getestet wurde. Für fehlerhaften und/oder vorschriftswidrigen Einsatz des Boards übernehmen wir keine Garantie. Safety Guidelines my7-segment is designed for educational and experimental use only. It is not intended and not dimensioned to control real industrial facilities. At correct use there will not occur extremely dangerous voltages. Nevertheless, be aware of general guidelines for using electronic devices. We assure that the PCB has been tested by the producer. For incorrect use and/or application contrary to technical regulations we are not liable.. Die aktuellsten Dokumente zum my7-segment finden Sie unter www.myavr.de im Downloadbereich. The latest documents for the my7-segment you can find at our homepage www.myavr.com under Download. Abbildungen können vom Inhalt abweichen. Änderungen im Sinne des technischen Fortschrittes behält sich der Hersteller vor. Images may vary from the content. The manufacturers retains changes in terms of technical advances.