Datasheet. Page 1 of 7

R&R. Ges. für Rationalisierung und Rechentechnik mbh. R&R RR-P-508 / ST106-EX1 motor-control unit

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

LORENZ MESSTECHNIK GmbH

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

ABB i-bus EIB. EIB Power Supply Units

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

Kuhnke Technical Data. Contact Details

Overview control units

Control shut-off butterfly valves DN 50 DN 400 PN

Lufft UMB Sensor Overview

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

MPC-460. Edition: Mobile Process Computer. Bemerkung/Remark: 1/6. Abmessungen/Dimensions [mm]:

a) Name and draw three typical input signals used in control technique.

Electrical tests on Bosch unit injectors

Datenblatt / Data sheet

2/2-way solenoid valve - Type 218

~XECRO. Vorteile: Weite Schaltabstände Durchgängiges PTFE-Gehäuse PTFE-gekapselte Schaltanzeige-LED PTFE-gekapseltes Trim-Potentiometer.

Telemetrie-Messtechnik Schnorrenberg

Electrical testing of Bosch common rail piezo injectors

Produktdatenblatt. Artikel Nr.: Wand- / Deckenleuchte, LED Panel RGB, Weiß, 24V DC, 36,00 W, RGB. Technische Daten.

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

Komponenten / Components

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Typenreihe GH Lifting Solenoids

(825M) 2-Draht-Sender

P A max. 100bar A P max. 16bar

Converter, switches and accessories LIGHT MEETS INNOVATION. lighting solutions

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W

Temperature Monitoring Unit TS-02. Users manual

External Electronic Controller Type S-EP 6

EINBAUHINWEISE INSTALLATION INSTRUCTIONS

Technical Data: Spezial-Steckanschluss (Bosch) Special push-on connector (Bosch)

A P max. 16bar P R max. 64bar R P max. 16bar

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Schalten einer kapazitiven Last mit einem Transistor

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten.

Datenblatt. P-series PDU 2.5/4/4AN

Fundamentals of Electrical Engineering 1 Grundlagen der Elektrotechnik 1

E/A-Bedieneinheit. I/O Control unit DE/GB 08/02

EINBAUHINWEISE INSTALLATION INSTRUCTIONS

4.2. Ausgangserweiterungseinheiten Output expansion units Unités d extension de sorties

TW-75-IP40Trackball. Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40. Description

Technische Daten / Technisches Merkblatt (nach pren ) ECHOGRAPH 1016B (Best.-Nr )

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

3. Technical data 3. Technische Daten

Software-Update Version manual. In order to keep your door systems updated, please proceed with the following changes.

Produktdatenblatt. Artikel Nr.: Pendelleuchte, Filo Ball, Silber, V AC/50-60Hz, 1x max. 40,00 W. Technische Daten.

CL I IP20. 9MX056 MDU-PWR Starter Set/Extension Set. Mounting instructions. New Installation/Neuinstallation. 9MX056 MDU-PWR Starter Set

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Rosado, Weiß, V AC/50-60Hz, 1x max. 40,00 W + 60,00 W.

rot red braun brown rot red RS-8 rot red braun brown R S V~

Certificate of conformity Generating unit, NS-protection

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Komponenten / Components

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Electrical testing of Bosch common rail Injectors

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Cube, Dunkelgrau, V AC/50-60Hz, 1x max. 25,00 W. Technische Daten.

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

direktgesteuert direct acting

Barcodescanner CLV62x, CLV63x, CLV64x, CLV65x

servogesteuert pilot operated

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

direktgesteuert direct acting

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.

ELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/

Komponenten / Components

Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

INCLUDES: Fully assembled 4 wheels for mobile use Power cable

Voxio Reader Overview 2018 / Voxio Leser Übersicht

TECHNICAL DATA SHEET Member of Uponor Group

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Weiß, 12V AC/DC, 1x max. 50,00 W. Technische Daten. Charakteristik.

Digital Display BDD-AM10-.-P

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 286 Type 286. fremdgesteuert externally controlled

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

02. Liquid Handling Dosiertechnik

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

Typenreihe GH Lifting Solenoids

Produktdatenblatt. Artikel Nr.: Deckeneinbauleuchte, COB 130, Weiß, 34,8V DC, 18,00 W, Warmweiß. Technische Daten.

Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range

ÜBERSICHT: UI21 UI48-TRANSFORMATOREN Overview: UI21 UI48-transformers

Serviceinformation Nr. 05/10

Surface-mounted ceiling lights 100% Profilkönig. UNEX DAKOTA AG Flüelastrasse 12 CH-8048 Zürich

Produktdatenblatt. Artikel Nr.: Wand- / Deckenleuchte, LED Panel RGB, Weiß, 24V DC, 38,00 W, RGB. Technische Daten.

BZ 873. Trainline Interface. Ident Nr.: 3EH R0001

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

Transkript:

Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses: External setpoint: Temperature sensor: Relays contact: Contact load open/close: Storage temperature: connector: Protection class: weight: 12 and 24V DC 10 to 18V DC 18 to 30V DC +15 C to +30 C 1K 10 k -Potentiometer, linear NTC, Siemens K276 1 potential-free 2-way contact 10/20A (resistive load) -20 C to +70 C -30 C to +85 C 10 AMP- FASTON 6,3x0,8mm IP20 approx. 115g dimensiones (mm): page:1 of:11

Thermostat TR-280 (0280.3.A00) Seite 1 The Thermostat TR-280 is a electronic three-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses relays: Reacting distance between relays: External setpoint: Temperature sensor: Relays contact: Contact load open/close: Storage temperature: Connector: Protection class: weight: 12V and 24V DC 10V to 18V DC 18V zo 30V DC +15 C to +30 C 1 K 1 K to 5 K adjustable 10 k -Potentiometer, linear PTC, KTY-14 2 potential-free 2-way contact 10/20A (resistive load) 11 AMP- FASTONr 6,3x0,8mm IP20 approx. 115g Interference immunity: According to DIN VDE 0839 part 1 Dimensiones: page:2 of:11

Thermostat TR-280 (0280.3.A00) Seite 2 Function The controller forms the difference between the set point ( adjustable with potentiometer ) and the actual value ( measured with external sensor ). At positiv control deviations (set point actual value) the relay is activated, at negativ control deviations the relay. The switch-point between the both relays is adjustable between 0,5 K and 5 K ( both relays off ). The adjustment is done with the potentiometer reacting distance. Each relay has a fixed hysteresis about 1 K, for avoid a permanent switching. The potentiometer Temp.corection gives the posibility to adjust the tolerances of the sensor. On reacting distance hysteresis Off temperature increasing temperature decreasing page:3 of:11

Thermostat TR-280 (0280.3.A00) Seite 3 Adjustements reacting distance relay correction sensor connection Power normally open contact normally open contact normally closed contact normally closed contact ground 12 V setpoint potentiometer 24 V sensor One terminal of setpoint potentiometer and sensor must be contacted to ground. page:4 of:11

Thermostat TR-282 (0282.3.A00) Seite 1 The Thermostat TR-282 is a electronic three-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses relays: Reacting distance between relays: External setpoint: Temperature sensor: Relays contact: Contact load open/close: Analog output: Storage temperature: Connector: Protection class: weight: 12V and 24V DC 10V to 18V DC 18V to 30V DC +15 C to +30 C 1 K 0,5 K to 5 K adjustable 10 k -Potentiometer, linear PTC, KTY-14 2 potential-free 2-way contact 10/20A (resistive load) 0 to supply voltage -2V, current 5mA 11 AMP- FASTON 6,3x0,8mm IP20 approx. 115g Interference immunity: according to DIN VDE 0839 part 1 Dimensiones: page:5 of:11

Thermostat TR-282 (0282.3.A00) Seite 2 Function The controller forms the difference between the set point ( adjustable with potentiometer ) and the actual value ( measured with external sensor ). At positiv control deviations (set point actual value) the relay is activated, at negativ control deviations the relay. The switch-point between the both relays is adjustable between 0,5 K and 5 K ( both relays off ). The adjustment is done with the potentiometer reacting distance. Each relay has a fixed hysteresis about 1 K, for avoid a permanent switching. The potentiometer Temp.corection gives the posibility to adjust the tolerances of the sensor. On reacting distance hystereses Off temperature increasing temperature decreasing The thermostat comes with a aditional analog output, e.g. for controlling of blower moduls. The voltage decreases proportionately to the control deviacion. With a suitable blower modul this causes to increase the rotation speed of the blower. Adjustable is the zero point (application point), movable over the complete controling range, as wel as the heights of the output voltage ( minimal speed ), adjustable from 0V to Ubat 2,5 V control voltage minimal speed application point 0 V too cold 1 C to warm page:6 of:11

Thermostat TR-282 (0282.3.A00) Seite 3 Adjustment zero point analog output amplifying analog output reacting distance relays correction sensor connection drawing Power normally open contact control voltage normally closed contact normally closed contact ground normally open contact 12 V setpoint potentiometer 24 V sensor One terminal of setpoint potentiometer and sensor must be contacted to ground. page:7 of:11

Thermostat TR-285P Seite 1 The Thermostat TR-282 is a electronic four-level controller for controlling of and in climate control units and vehicles. He works like a three-level controller with one addcional contact. Voltage range (12V): Voltage range (24V): Control range: Hystereses: External setpoint: Temperature probe: Relays contact: Contact load open/close: Storage temperature: Connector: Protection class: weight: 12V and 24V DC 10V to 18V DC 18V to 30V DC +15 C to +30 C 0,5K to 5K adjustable 10 k -Potentiometer, linear NTC, KTY-14 3 potential-free 2-way contact 10/ 20A (resistive load) 14 AMP- FASTON 6,3x0,8mm IP20 approx. 120g Interference immunity: According to DIN VDE 0839 part 1 Article no. 12V version Article number 24V version 0285.1.A00 0285.2.A00 Dimensiones: page:8 of:11

Thermostat TR-285 Seite 2 Function The controller forms the difference between the set point ( adjustable with potentiometer ) and the actual value ( measured with external sensor ). At positiv control deviations (set point actual value) the relay is activated, at negativ control deviations the relay. The switch-point between the both relays is adjustable between 0,5 K and 5 K ( both relays off ). The adjustment is done with the potentiometer reacting distance. Each relay has a fixed hysteresis about 1 K, for avoid a permanent switching. The potentiometer Temp.corection gives the posibility to adjust the tolerances of the sensor. Increases the control deviation an adjustable value, a more relay is switched( increased efficiency ). The relay works in both direction, thus to increase the power as well as the power. The switch point is adjustable with the potentiometer power. When reaching the setpoint, all relays are switched off. Reacting distance / On power power off temperature increasing temperature decreasing connection reacting distance power 24 V 12 V ground ground ground setpoint potentiometer sensor 10 8 1 1 1 7 9 6 11 12 4 2 3 5 Schaltspannung normal open contact normal closed contact normal open contact normal closed contact normal open contact normal closed contact power One terminal of setpoint potentiometer and sensor must be contacted to ground.. page:9 of:11

Thermostat TR-330 The Thermostat TR-330 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses: External set point: Temperature sensor: Relays contact: Contact load open/ close at 23 C: Contact load open/ close at 23 C: Storage temperature: Connector: Protection class: Weight: 12V and 24V DC 10V to 18V DC 18V to 30V DC +15 C tos +30 C approx. 2K 10 k -Potentiometer, linear NTC 20k 1 potential-free 2-way contact 30/ 45A (resistive load) 25/ 30A (resistive load) -25 C to +85 C -25 C to +90 C 15 pole Junior- Timer plug connector IP53 approx. 90g Interference immunity: According to DIN VDE 0839 part 1 Dimensiones: page:10 of:11

Thermostat TR-406 The Thermostat TR-282 is a electronic three-level controller for controlling of and in climate control units and vehicles. Microproceccor- controlled, with triple-digit 7segm LED. Voltage range: 24V DC 16V to 30V DC Control range: +15 C to +30 C or 59 F to 88 F Hystereses: Temperature sensor: Digital output: Power consumption without load Storage stemperature: Connector: Weight: approx. 2K NTC 20k 24V DC/ 0,5A kurzschlussfest approx. 40mA 6 AMP- FASTON 6,3x0,8mm approx. 65g Dimensiones: page:11 of:11