1 Facts and Figures 독일 LAYHER( 레이허 ) DC 전압전용압력스위치 보호캡 AC/DC 공용압력스위치 3 3 DC 전압전용진공스위치 33 AC/DC 전압공용진공스위치 34

2 Facts and Figures AC/DC 전압공용차압스위치 - 유압, 수압, 고압에적용 35 TYE ~ bar 36 TYE ~ 3bar 37 TYE 70 ~ 0bar, 5 ~ 50bar 전자식압력스위치 - 유압, 수압, 고압에적용 38 TYE 90 디지털형전자식압력스위치 - 유압, 수압, 고압에적용 39 TYE 930

3 Bestellhinweis Order Advice Schaltschema Wiring diagram Schließer NO-Contact... Öffner NC-Contact... Wechsler Change-over Contact... 3 Membrane / Dichtung Membrane / Seal NBR... VITON... CR... 3 EDM... 4 UR... 5 KALREZ... 6 Metall Steel... 7 HNBR... 8 Anschlußgewinde Fitting thread G /4"... G /8"... Mx, M0x kegelig Cone... 4 Mx, G /8" NT... 6 Flanschmontage Flange-mounting... 7 M0x... 8 IG Mx,5... B Kontakte Contacts versilbert silvered... vergoldet gilded... Werkstoff Material Stahl verzinkt Galvanized steel... VA.4305 Stainless steel... VA.457 Stainless steel... 3 Messing Brass... 4 Al Aluminium... 5 Stand As of date 0. Bestell-Nr. Order no. Ausführung-Nr. Configuration no. Technische Änderungen vorbehalten Technical data subject to change without notice. LAYHER AG, Kalkwerkstr. 3, 7737 Kirchberg, Germany, Tel. +49 (0 ) , Fax +49 (0) , info@layherag.de,

4 Druckschalter ressure Switch Typ 40 Schließer / Öffner NO-Contact / NC-Contact dia ( Membranschalter membranswitch ) 48 ( Kolbenschalter pistonswitch ) 3 SW 4 a/f 4 A Einstellschraube Setting screw M5 DIN 94 NO-Contact NC-Contact Bestellnummer Order no Druckeinstellbereich ressure setting range 0, - bar - 0 bar 0-70 bar bar Toleranz Tolerance ± 0, bar ± 0,5 bar ± 3,0 bar ± 5,0 bar ± 0,0 bar Arbeitsdruck max. Working pressure max. bar 0 bar 70 bar 00 bar 350 bar Berstdruck Bursting pressure 0 bar 00 bar 50 bar 300 bar 500 bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Kolben federbelastet Spring-loaded piston Membrane Diaphragm / Dichtung Seal NBR Sonderausführung Special design VITON, EDM UR Sonderausführung Special design VITON Befestigungsart Manner of fastening über Außengewinde Male thread Anschlußgewinde >A< Fitting thread >A< G /4", G /8", Mx,5, M0x kegelig G /4", G /8", Mx,5, M0x Cone Rückschaltdifferenz Switch back difference 0% - 5% Stahl verzinkt, Sonderausführung VA Galvanized steel, special design stainless steel 90 g 05 g Kontakte versilbert, Sonderausführung vergoldet Silver-plated contacts / special gold-plated contacts 4 V Maximalbelastung Maximum load A (Ohmsch resistive) Elektrischer Anschluß Electrical connection Flachstecker x 6,3 x 0,8, wahlweise konfektioniert mit Kabel Flat plug x 6.3 x 0.8, optionally made up with cable Schutzart rotective system I65, Klemmen I00, konfektioniert I 67 (SW 7) I65, terminals I00, made up I 67 (a/f 7) Schaltleistung Breaking capacity 00 VA Weitere Informationen siehe Gebrauchsanweisung (GBA) für Membran- und Kolbendruckschalter Further information see Operating Instruction (OI) for Membrane and iston ressure Switch - 8 -

5 Schutzkappen rotective Cap dia. 9 ca. approx. 46 dia. 4 dia. 6 dia. 6,5 dia. 5 dia. 3,5 dia. 3 3,5 40 dia. 6 dia. 9 dia. 4 ca. approx. 5 dia dia.,7, ,5,5 dia.4 dia.8 dia.6 dia. dia. 3 dia. 7 dia. 30,5 dia. 36,5 g7 Typ 0 K Typ 4 K Typ 50 K Typ 360 K für for für for für for für for Typ 0 Typ 3 / Typ 4 Typ 50 Typ 360,5,5 33,5,5 dia. 4 dia. 3 dia. 7 dia. 3 dia. 33 dia. 33 Schraube Screw M6 DIN 84 Typ 400K Typ 4 K Typ 445 K für for für for für for Typ 300 / Typ 400 / Typ 406 / Typ 40 Typ 40 Typ 434 / Typ 435 g9 TECHNISCHE DATEN TECHNICAL DATES Schutzkappe rotective Cap Typ 0 K Typ 4 K Typ 50 K Typ 360 K Typ 400 K Typ 4 K Typ 445 K Bestellnummer Order no K K K K K K K NBR 55 Sh NBR 55 Sh A6 NBR 55 Sh NBR 55 Sh NBR 55 Sh A6 Temperatur Temperature 5 bis +85 C 5 bis +85 C 5 bis +85 C 5 bis +85 C 5 bis +85 C 5 bis +85 C 5 bis +85 C,5 g,5 g 3 g 0,5 g 8,5 g 8 g 7 g Technische Änderungen vorbehalten Technical data subject to change without notice. LAYHER AG, Kalkwerkstr. 3, 7737 Kirchberg, Germany, Tel. +49 (0 ) , Fax +49 (0) , info@layherag.de,

6 Rundstecker-Anschluß Round plug connection Mx 48 Kupplungsdose coupler socket g9 Druckschalter ressure Switch Typ 550 Wechsler Change-over Contact 80 ( Membranschalter membranswitch ) 87 ( Kolbenschalter pistonswitch ) 7 89 ( Membranschalter membranswitch ) 96 ( Kolbenschalter pistonswitch ) 7 30 Drehbar rotatable 360 SW 7 a/f A A Alle Angaben in mm All specification in mm dia. 6 Einstellschraube setting screw M3 DIN 94 dia. 6 Einstellschraube setting screw M4 DIN Elektrischer Anschluss Electrical connection Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range 0,5 bar 0 bar 0 70 bar bar Toleranz Tolerance ± 0, bar ± 0,5 bar ± 3,0 bar ± 5,0 bar Arbeitsdruck max. Working pressure max. bar 0 bar 70 bar 00 bar Berstdruck Bursting pressure 0 bar 0 bar 0 bar 300 bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Kolben federbelastet Spring-loaded piston Membrane Diaphragm / Dichtung Seal NBR Sonderausführung Special design VITON, EDM UR Sonderausführung Special design VITON Befestigungsart Manner of fastening über Außengewinde Male thread Anschlußgewinde >A< Fitting thread >A< G /4", G /8", Mx,5, M0x kegelig G /4", G /8", Mx,5, M0x Cone Rückschaltdifferenz Switch back difference 5 % 0% Stahl verzinkt, Sonderausführung Messing, VA Galvanized steel, special design brass or stainless steel 0g 40 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 4 V Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN wahlweise Rundstecker Mx Connector G9 DIN EN Round plug Mx Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A

7 Druckschalter ressure Switch Typ 600 Wechsler Change-over Contact Einstellschraube setting screw M5 DIN 94 dia. 30 X 39 Kupplungsdose coupler socket g Drehbar rotatable 360 SW 4 a/f 4 A X 9 Rundstecker-Anschluß Mx Alle Angaben in mm All specification in mm Elektrischer Anschluss Electrical connection 4 4 Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range 0,3 - bar - 0 bar 0-70 bar bar Toleranz Tolerance ± 0, bar ± 0,5 bar ± 3,0 bar ± 5,0 bar Arbeitsdruck max. Working pressure max. bar 0 bar 70 bar 00 bar Berstdruck Bursting pressure 0 bar 0 bar 50 bar 300 bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Kolben federbelastet Spring-loaded piston Membrane / Dichtung Diaphragm / seal NBR Sonderausführung Special design VITON, EDM, KALREZ UR Sonderausführung Special design VITON Befestigungsart Manner of fastening über Außengewinde Male thread Anschlußgewinde >A< Fitting thread >A< G /4", G /8", Mx,5, M0x kegelig G /4", G /8", Mx,5, M0x Cone Rückschaltdifferenz Switch back difference 5 % 5% Stahl verzinkt, Sonderausführung Messing, VA Galvanized steel, special design brass or stainless steel 30 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 50 V (G9), 4 V (Rundstecker Mx) Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN , wahlweise Rundstecker Mx Connector G9 DIN EN , optionally with round plug Mx Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A - 3 -

8 Druckschalter ressure Switch Typ 60 Einstellschraube Setting screw M6 DIN 94 dia Kupplungsdose Coupler socket g9 Wechsler Change-over Contact 4 5 M 4 66 dia. 8 dia. 5,3 Bei Gewinde-Anschluß G/4" Verschlußstopfen entfernen. In case of thread-connection G/4" remove seal-plug. Bei Flanschmontage Schraube DIN 9 entfernen O-Ring 5x wird mitgeliefert. In case of flange-mounting remove screw DIN 9 O-ring 5 x is enclosed. Alle Angaben in mm All specification in mm X 9 Rundstecker-Anschluß Round plug connection Mx 3 0 Elektrischer Anschluss Electrical connection Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range bar Toleranz Tolerance ± 0,0 bar Arbeitsdruck max. Working pressure max. 400 bar Berstdruck Bursting pressure 600 bar Bauart Design Kolben federbelastet Spring-loaded piston Dichtung Seal UR, Sonderausführung VITON UR, Special design VITON Befestigungsart Manner of fastening Innengewinde oder über Durchgangsbohrungen im Gehäuse Forale thread or by through holes in the case Anschlußgewinde Fitting thread G /4", wahlweise Flanschmontage G /4, alternatively flange-connection Rückschaltdifferenz Switch back difference 5 % 5% Stahl verzinkt, Sonderausführung VA Galvanized steel, special design stainless steel 370 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 50 V (G9), 4 V (Rundstecker Mx) Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN , wahlweise Rundstecker Mx Connector G9 DIN EN , optionally with round plug Mx Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A - 3 -

9 Vakuumschalter Vacuum Switch Typ 300 Wechsler Change-over Contact dia. 4 SW 7 a/f ,6 A dia. 9 Alle Angaben in mm All specification in mm Einstellschraube Setting screw M5 DIN 94 4 Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range mbar Toleranz Tolerance ± 00 mbar Berstdruck Bursting pressure bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Membrane Diaphragm NBR, Sonderausführung VITON, EDM NBR, special design VITON, EDM Befestigungsart Manner of fastening über Außengewinde Male thread Anschlußgewinde >A< Fitting thread >A< G /8", andere Gewinde auf Anfrage G /8", Other thread types on demand Rückschaltdifferenz Switch back difference 5 % 5% Messing, Sonderausführung VA, Stahl verzinkt Brass, special design stainless steel, galvanized steel 0 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 4 V Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Flachstecker 3 x 6,3 x 0,8 Flat plug 3 x 6.3 x 0.8 Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A

10 Vakuumschalter Vacuum Switch Typ 330 Wechsler Change-over Contact dia Kupplungsdose coupler socket g 9 DIN A Drehbar rotatable 360 SW 4 a/f 4 Einstellschraube setting screw M5 DIN 94 Alle Angaben in mm All specification in mm 4 Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range mbar Toleranz Tolerance ± 00 mbar Berstdruck Bursting pressure bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Membrane Diaphragm NBR, Sonderausführung VITON, EDM NBR, special design VITON, EDM Befestigungsart Manner of fastening über Außengewinde Male thread Anschlußgewinde >A< Fitting thread >A< G /4", G /8", andere Gewinde auf Anfrage G /4", G /8", Other thread types on demand Rückschaltdifferenz Switch back difference 5 % 5% AL / Messing Aluminium / Brass 0 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 50 V Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN Connector G9 DIN EN Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A Weitere Informationen siehe Gebrauchsanweisung (GBA) für Vakuumschalter Further information see Operating Instruction (OI) for Vacuum Switch Technische Änderungen vorbehalten Technical data subject to change without notice. LAYHER AG, Kalkwerkstr. 3, 7737 Kirchberg, Germany, Tel. +49 (0 ) , Fax +49 (0) , info@layher-ag.de,

11 Differenz-Druckschalter Differential ressure Switch Typ 705 dia. 5 dia. 30 Wechsler Change-over Contact G /8" Minus G /8" lus Alle Angaben in mm All specification in mm Kupplungsdose Coupler socket g9 Einstellschraube Setting screw M5 DIN 94 4 Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range 0,3 bar Toleranz Tolerance ± 0, bar Arbeitsdruck max. Working pressure max. 0 bar Berstdruck Bursting pressure Statischer Druck max. 5 bar Static pressure max. 5 bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Membrane Diaphragm NBR, Sonderausführung VITON, EDM NBR, special design VITON, EDM Befestigungsart Manner of fastening 4 x M3 Bohrungen im Gehäuse through 4 bore M 3 Anschlußgewinde Fitting thread x G /8" Rückschaltdifferenz Switch back difference 5 % 5% Messing, Sonderausführung Stahl verzinkt, VA Brass, special design galvanized steel or stainless steel 430 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 50 V Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN Connector G9 DIN EN Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A

12 Differenz-Druckschalter Differential ressure Switch Typ 70 Wechsler Change-over Contact dia. 8 dia. 40 G /8" Minus G /8" lus dia Differenzdruck - Einstellschraube Differential setting screw SW 6 a/f 6 Kupplungsdose Coupler socket g 9 Alle Angaben in mm All specification in mm 4 Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range 0,5-3 bar Toleranz Tolerance ± 0, bar Arbeitsdruck max. Working pressure max. 0 bar Berstdruck Bursting pressure Statischer Druck max. 5 bar Static pressure max. 5 bar Bauart Design Membrane federbelastet Spring-loaded diaphragm Membrane Diaphragm NBR, Sonderausführung VITON, EDM NBR, special design VITON, EDM Befestigungsart Manner of fastening Durchgangsbohrungen im Gehäuse through holes in the case Anschlußgewinde Fitting thread x G /8" Rückschaltdifferenz Switch back difference 5 % 5% Messing, Sonderausführung Stahl verzinkt, VA Brass, special design galvanized steel or stainless steel 030 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 50 V Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN Connector G9 DIN EN Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A

13 Differenz-Druckschalter Differential ressure Switch Typ 70 dia. 8 dia. 40 Wechsler Change-over Contact G /8" Minus G /8" lus dia Differenzdruck - Einstellschraube Differential setting screw SW 6 a/f 6 Kupplungsdose Coupler socket g 9 DIN Alle Angaben in mm All specification in mm 4 Change-over Contact Bestellnummer Order no Druckeinstellbereich ressure setting range 0 bar 5 50 bar Toleranz Tolerance ± 0,5 bar ± 3,0 bar Arbeitsdruck max. Working pressure max. 50 bar 50 bar Berstdruck Bursting pressure Statischer Druck max. 00 bar Static pressure max. 00 bar Statischer Druck max. 350 bar Static pressure max. 300 bar Bauart Design Kolben federbelastet Spring-loaded piston Dichtung Seal UR, Sonderausführung VITON UR, Special design VITON Befestigungsart Manner of fastening Durchgangsbohrungen im Gehäuse through holes in the case Anschlußgewinde Fitting thread x G /8" Rückschaltdifferenz Switch back difference 5 % 5% Stahl verzinkt, Sonderausführung VA Galvanized steel, special design stainless steel 5 g Microschalter Kontakte versilbert, Sonderausführung vergoldet Microswitch - silver-plated contacts / special gold-plated contacts 50 V Bemessungsfrequenz Reference frequency nicht über 00 Hz Not over 00 Hz Elektrischer Anschluß Electrical connection Kupplungsdose G9 DIN EN Connector G9 DIN EN Schutzart rotective system I 65, Klemmen I 00 DIN I65, terminale I00 DIN Schaltleistung Gebrauchskategorie nach EN60947 Wechselstrom Gleichstrom Breaking capacity Utilization category according to EN60947 AC DC Spannung bis Voltage up to 5 V 50 V 30 V 50 V 75 V 5 V 50 V Widerstand-Last Resistance load AC-, DC- 5 A 5 A 5 A A A 0,5 A 0,5 A Induktive-Last Inductive load AC-4, DC-3 A A A A 0,5 A 0, A 0, A

14 Drucksensor ressure Sensor Typ 90 9 Sensor Mx,0 Schaltpunkt programmieren: Den Ring drehen und somit die Öffnung freilegen. Switch point program: Turn the ring and expose opening. A SW ,5 73,5 Alle Angaben in mm All specification in mm SW Bestellnummer Order no. N NN N N N N Druckbereich ressure range 0-0 bar 0-00 bar 0-50 bar bar Berstdruck Burst ressure 0 bar 50 bar 400 bar 600 bar Ausgang Output programmierbarer Schaltausgang (A) rogrammable switching outputs (A) Genauigkeit Accuracy % 0 C bis + 85 C 0 C to +85 C Anschlußgewinde Fitting thread G /4" Außengewinde G /4" Male thread Medien Media Luft, Ölemulsion, Wasser, andere Medien auf Anfrage Air, oil emulsion, water, others on demand Druckgehäuse ressure housing Edelstahl VA.4305 Stainless Steel VA.4305 Drucksensor ressure sensor Keramikmesszelle mit entsprechendem O-Ring Ceramic measuring cell with appropriate O-ring Elektrischer Anschluß Electrical connection Steckverbinder Mx lug-in connector Mx Schutzart rotective system I 54 (bei geschlossenem Ring with closed ring) Nennspannung Nominal voltage 4 V DC Betriebsspannung Operating Voltage 8 bis 3 V DC 8 to 3 V DC Stromverbrauch Current consumption 50 ma Schaltzyklen Switching cycles 4 x g Weitere Informationen siehe Gebrauchsanweisung (GBA) für Drucksensor Typ 90 Further information see Operating Instruction (OI) for ressure Sensor Typ 90 Stand As of date

15 Drucksensor ressure Sensor Typ 930 Rundstecker-Anschluß Round plug connection Mx Sensor A SW ,5 Drehbar rotatable 70 40,5 9 Alle Angaben in mm All specification in mm Bestellnummer Order no. N NN N N N Druckbereich ressure range 0-0 bar 0-00 bar 0-50 bar Berstdruck Burst ressure 0 bar 50 bar 400 bar Ausgang Output programmierbare Schaltausgänge ( je 0,5A) rogrammable switching outputs (each 0,5A) Genauigkeit Accuracy % ± Digit % ± Digit 0 C bis + 70 C 0 C to +70 C Anschlußgewinde Fitting thread G /4" Innengewinde G /4" Internal thread Medien Media Luft, Ölemulsion, Wasser, andere Medien auf Anfrage Air, oil emulsion, water, others on demand Druckgehäuse ressure housing Edelstahl VA.4305 Stainless Steel VA.4305 Drucksensor ressure sensor Keramikmesszelle mit entsprechendem O-Ring Ceramic measuring cell with appropriate O-ring Elektrischer Anschluß Electrical connection Steckverbinder Mx lug-in connector Mx Schutzart rotective system I 54 Nennspannung Nominal voltage 4 V DC Betriebsspannung Operating Voltage 8 bis 3 V DC 8 to 3 V DC Stromverbrauch Current consumption 00 ma ( Ausgänge unbelastet ) 00 ma ( Outputs unloaded ) Schaltzyklen Switching cycles 4 x g Weitere Informationen siehe Gebrauchsanweisung (GBA) für Drucksensor Typ 930 Further information see Operating Instruction (OI) for ressure Sensor Typ

16

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,

Mehr

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,

Mehr

Druckschalter, Pressure Switch Vakuumschalter, Vacuum Switch Differenz-Druckschalter, Differential Pressure Switch Drucksensor, Pressure Sensor

Druckschalter, Pressure Switch Vakuumschalter, Vacuum Switch Differenz-Druckschalter, Differential Pressure Switch Drucksensor, Pressure Sensor Flexible Technologie Flexible technology, Vakuumschalter, Vacuum Switch Differenz-, Differential Drucksensor, ressure Sensor Ein komplettes roduktprogramm complete product program Seite age 3 Komplettprogramm

Mehr

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil

TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil TECHNISCHE DATEN Leistungsrelais Zweispuliges TECHNICAL DATA Power Relay Dual-coil Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3

Mehr

Druckschalter Transmitter Pressure Switch Transmitters

Druckschalter Transmitter Pressure Switch Transmitters Druckschalter Transmitter Pressure Switch Transmitters 41 Druckschalter llfluid - 4 bar Pressure Switch llfluid - 58 si Betriebssannung Oerating voltage Stromaufnahme ohne Schaltausgang Current consumtion

Mehr

TECHNISCHE DATEN Hochleistungsrelais TECHNICAL DATA High Power Relay

TECHNISCHE DATEN Hochleistungsrelais TECHNICAL DATA High Power Relay TECHNISCHE DATEN Hochleistungsrelais TECHNICAL DATA Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3 Serie 911 Hochleistungsrelais

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN

Mehr

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

2/2-way solenoid valve - Type 239

2/2-way solenoid valve - Type 239 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 10 40 Druckbereich Gehäusewerkstoff Messing Dichtw erkstoff Sitzventil mit

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

2/2-way solenoid valve - Type 218

2/2-way solenoid valve - Type 218 - direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator Bauart Nennweite DN 8 DN 50 Anschluss Kugelhahn mit pneumatischem Schwenkantrieb G1/4 G2 Betriebsdruck Messing: DN15 DN20 = PN30 DN25 = PN16 DN32 DN50 = PN10 Edelstahl: PN63 Gehäusewerkstoff Armatur: Edelstahl

Mehr

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303

diameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite

Mehr

A P max. 16bar P R max. 64bar R P max. 16bar

A P max. 16bar P R max. 64bar R P max. 16bar direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich

Mehr

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

TECHNISCHE DATEN Drucksensor Elektronischer Druckschalter TECHNICAL DATA Pressure Sensor Electronic Pressure Switch

TECHNISCHE DATEN Drucksensor Elektronischer Druckschalter TECHNICAL DATA Pressure Sensor Electronic Pressure Switch TECHNISCHE DATEN Drucksensor Elektronischer Druckschalter TECHNICAL DATA Pressure Sensor Seite Modell Bauart Messzelle Ausgang Page Model Design Measuring cell Output 2-3 Typ 800 Drucksensor Pressure Sensor

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich

Mehr

direktgesteuert direct acting

direktgesteuert direct acting 1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff

Mehr

3. Technical data 3. Technische Daten

3. Technical data 3. Technische Daten 661 078 3. Technical data 3. Technische Daten Design / Bauart Pressure switch, vacuum switch and differential pressure switch / Druckwellenschalter, Vakuumschalter und Differenzdruckschalter Function

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Schnellentlüftungsventil Nennweite DN 2,0 2,5 Schnellentlüftung DN 6,0 Druckbereich Gehäusewerkstoff

Mehr

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar] NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,

Mehr

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... DIGICONTROL- Gerätedatenblatt F-SPT-U www.gfr.de [82252] Kategorie: Sensoren und Wächter Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... Anwendung Der Druckmessumformer F-SPT-U...

Mehr

Induktive Näherungsschalter

Induktive Näherungsschalter www.ietz-sensortechnik.de support@ietz-sensortechnik.de Phone: +49(0)6252 94299-0 atenblatt INS-HL-01 Hochleistungsprogramm www.ietz-sensortechnik.de support@ietz-sensortechnik.de Phone: +49(0)6252 94299-0

Mehr

2/2-way plastic solenoid valve - Type 110

2/2-way plastic solenoid valve - Type 110 - direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 6,0 Druckbereich Sitzventil

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135 zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff

Mehr

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert

Mikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,

Mehr

Datenblatt / Data sheet

Datenblatt / Data sheet Seite/Page 1/5 Abbildungen / Illustration Maßzeichnung / Dimensions Produktbeschreibung Product specification Kompaktes, steckbares Relais für den industriellen Einsatz. Compact, pluggable relay for industrial

Mehr

servogesteuert pilot operated

servogesteuert pilot operated 1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung

Mehr

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direct acting with isolating diaphragm fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite

Mehr

P A max. 100bar A P max. 16bar

P A max. 100bar A P max. 16bar 1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design

Mehr

G WK. Spezial-Bajonett-Anschluss Special bajonet connector

G WK. Spezial-Bajonett-Anschluss Special bajonet connector Drucksensor mit Warnkontakt (3 Anschlüsse) Pressure Sensor with Warning Contact (3 Pin) Technische Daten: Nennspannung: 6V bis 24V Verlustleistung: < 250 mw ess-strom > 20 ma Warnkontakt: Schließt bei

Mehr

Pressure Switch Series HDS

Pressure Switch Series HDS HERION & RAU Pressure Switch Series HDS Electromechanical Pressure Switch Switching point adjustable:10 320 bar Max. pressure: 350 bar Hydraulic 90032.0305 Features With the Pressure Switch series HDS

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 286 Type 286. fremdgesteuert externally controlled

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 286 Type 286. fremdgesteuert externally controlled fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 8 Druckbereich

Mehr

Drucksensor mit Warnkontakt (über Masse) Pressure Sensor with Warning Contact (common ground) Rated voltage: 6V to 24 V Power Dissipation: < 250 mw

Drucksensor mit Warnkontakt (über Masse) Pressure Sensor with Warning Contact (common ground) Rated voltage: 6V to 24 V Power Dissipation: < 250 mw Drucksensor mit Warnkontakt (über Masse) Pressure Sensor with Warning Contact (common ground) Technische Daten: Nennspannung: 6V bis 24V Verlustleistung: < 250 mw Mess-Strom > 20 ma Warnkontakt: Schließt

Mehr

DRUCKSCHALTER PUSH SWITCHES

DRUCKSCHALTER PUSH SWITCHES DRUCKSCHALTER PUSH SWITCHES Zur Handbetätigung oder verdeckter-, mechanischer Betätigung. Unterschiedliche Beschaltungen als Öffner-, Schließer- oder Haltekontakt. Ausführungen wahlweise mit Steck- oder

Mehr

3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled

3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012 Baureihe 786-E Type 786-E fremdgesteuert externally controlled Schaltfunktion: function: NC (stromlos geschlossen) NC (normally closed) Elektrischer Anschluss M12x1 electrical connector M12x1 Bauart stufenlose

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W

DIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 15 50

Mehr

TECHNICAL DATA. Double-acting pneumatic telescopic cylinder

TECHNICAL DATA. Double-acting pneumatic telescopic cylinder TECHNISCHE DATEN TYP PDT Pneumatisch doppeltwirkender Teleskopzylinder TECHNICAL DATA TYP PDT Double-acting pneumatic telescopic cylinder Pneumatisch doppeltwirkende Teleskopzylinder mit Endlagendämpfung,

Mehr

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow 1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

Baureihe 280 / 281 / 282 Type 280 / 281 / 282

Baureihe 280 / 281 / 282 Type 280 / 281 / 282 1 fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally

Mehr

Schmitter Hydraulik GmbH 97450 Arnstein Tel.: +49 (0) 93 63/60-0 Fax: 60-14

Schmitter Hydraulik GmbH 97450 Arnstein Tel.: +49 (0) 93 63/60-0 Fax: 60-14 Steckverschraubungen plug-in connections Stecksystem mit elastischer Spannzange aus Edelstahl kleine Baugröße und geringes Gewicht silikonfreie O-Ringe O-Ring in Dichtkehle für rauhe Oberflächen Innensechskant

Mehr

Inhaltsverzeichnis Index

Inhaltsverzeichnis Index Inhaltsverzeichnis Index Typ Type Seite Page FDL 7-1 FDR 7-2 FMR 7-3 7-0-1 Zahnradmengenteiler Rotary geared flow divider Zahnradmengenteiler Typ FDL Rotary geared flow divider type FDL Technische Daten

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung

Mehr

2/2-way plastic solenoid valve - Type 104

2/2-way plastic solenoid valve - Type 104 - direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 1,0 2,5 Druckbereich Gehäusewerkstoff

Mehr

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H. ZU 0859 Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H www.knick.de Bauart und Funktion Der Endlagenschalter ZU 0859 wandelt die pneumatischen Endlagen signale,

Mehr

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Serie Series L-BV2 L_200 Flüssigkeitsringpumpen Liquid ring pumps 3 AC; 50/60 Hz 3 AC; 50/60 Hz Druckbetrieb Pressure operation Typen Types 2BV2

Mehr

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011 Handbetätigt allseitig mit Innengewinde mit T- oder L- Bohrung hand actuated all ports female thread with T- or L- configuration Bauart Nennweite DN 10 50 Betriebsdruck Handhebel Gehäusewerkstoff Kugelwerkstoff

Mehr

Kugelhähne Ball-valves

Kugelhähne Ball-valves 163 Ball-valves Features u u unterschiedliche Baureihen für flexible Anwendungen Mini- auch mit Steckanschluss u u Various lines for flexible applications Mini ball valves also with plug connection 164

Mehr

Handling a complex world Druckgeber (1polig über Masse) Technische Daten: Nennspannung: 6V bis 24V Überdrucksicherheit: max 30 bar, 40 bar oder 50 bar

Handling a complex world Druckgeber (1polig über Masse) Technische Daten: Nennspannung: 6V bis 24V Überdrucksicherheit: max 30 bar, 40 bar oder 50 bar Handling a complex world (1polig über Masse) Technische Daten: Nennspannung: 6V bis 24V Überdrucksicherheit: max 30, 40 oder 50 (kurzzeitig bis 2 Sekunden) Betriebstemperatur: 25 C bis + 100 C (bis + 120

Mehr

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87 Magnetventile Solenoid Valves Betätigungsmagnet Typ 64 für Baureihe 64/79///7 Type 64 for Series 64/79///7 Elektrische Daten 64er Magnetsystem Elektrische Ausführung: gemäß VDE 050, VDE 00 Ansprechstrom:

Mehr

TECHNISCHE DATEN Leistungsrelais Bistabil TECHNICAL DATA Power Relay Bistable

TECHNISCHE DATEN Leistungsrelais Bistabil TECHNICAL DATA Power Relay Bistable TECHNISCHE DATEN Leistungsrelais Bistabil TECHNICAL DATA Seite Modell Bauart Funktion Dauerstrom Elektrischer Anschluß Page Model Design Function Duty rating Electrical link 2-3 Serie 400 Bistabil Bistable

Mehr

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Serie Series L-BV2 L_200 Flüssigkeitsringpumpen Liquid ring pumps 3 AC; 50/60 Hz 3 AC; 50/60 Hz Vakuumbetrieb Vacuum operation Typen Types 2BV2

Mehr

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012

Schaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012 fremdgesteuert externally controlled Schaltfunktion function Elektrischer Anschluss M12x1 electrical connector M12x1 Die Ventile arbeiten als Druckwaage und werden im Bypass eingesetzt. Der Mediumsdruck

Mehr

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Serie Series L-BV7 L_200 Flüssigkeitsringpumpen Liquid ring pumps 3 AC; 50/60 Hz 3 AC; 50/60 Hz Druckbetrieb Pressure operation Typen Types 2BV7

Mehr

DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES

DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES Ecksicherheitsventile aus Rotguss mit Nirofeder Typ 606 GF/GFL/tGF für neutrale Flüssigkeiten,Dampf und gasförmige Medien Safety valves made of red brass

Mehr

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump Serie Series L-BV7 L_200 Flüssigkeitsringpumpen Liquid ring pumps 3 AC; 50/60 Hz 3 AC; 50/60 Hz Vakuumbetrieb Vacuum operation Typen Types 2BV7

Mehr

IDG. Drehzahlsensor / Speed Sensor

IDG. Drehzahlsensor / Speed Sensor Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor

Mehr

RQ LR24. SK - VA - L

RQ LR24. SK - VA - L System RQ30 Rundtaster mit Schnellverschraubung round pushbutton with quick screw connection Merkmale Features geringer Hub 1,0 mm geringe Bauhöhe ca. 36 mm inkl. homogene Randausleuchtung durch LEDs Metallkragen

Mehr

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control Technische Daten BAUFORM Druckgesteuertes Nadelventil mit aufgebautem Stellungsregler PG01. Specification DESIGN Pressure actuated needle valve with electropneumatic positioner. Artikel: AND STEUERFUNKTIONEN

Mehr

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series 3/2-way, G 1/4, Technical data for series -310-311 -312-320 -320-Q -322-322-Q Design and function Pneumatically operated spool valve. The valve switches upon pressurization of the pilot port (10 or 12).

Mehr

Baureihe 280 / 281 / 282 Type 280 / 281 / /2-Wege Coaxialventil 2/2-way coaxial valve. fremdgesteuert externally controlled

Baureihe 280 / 281 / 282 Type 280 / 281 / /2-Wege Coaxialventil 2/2-way coaxial valve. fremdgesteuert externally controlled fremdgesteuert externally controlled Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50

Mehr

TECHNISCHE DATEN TYP D TECHNICAL DATA

TECHNISCHE DATEN TYP D TECHNICAL DATA TECHNISCHE DATEN TYP D Hydraulik Differentialzylinder ohne Endlagendämpfung TECHNICAL DATA TYP D Hydraulic differential cylinder without end position damping Hydraulik Differentialzylinder ohne Endlagendämpfung,

Mehr

Wir setzen Standards. Connector 4 Small Drives TWINTUS

Wir setzen Standards. Connector 4 Small Drives TWINTUS Wir setzen Standards Connector Small Drives Connector small drives Das kosteneffiziente Stecksystem für energieeffiziente Servomotoren Cost effective connectors for energy efficient servo drives Minimale

Mehr

Rohrschieber mit Schließfeder Slide Valve spring loaded

Rohrschieber mit Schließfeder Slide Valve spring loaded Rohrschieber mit Schließfeder Slide Valve spring loaded Rohrschieber als automatisches Entlüftungsventil Slide Valve as automatic air relief valve Type: RSF DN: 50 300 (2 12 ) PN: 16 160 (Class 150 900)

Mehr

Sechskantmutter Hexagonal locknut

Sechskantmutter Hexagonal locknut Sechskantmutter Hexagonal locknut Sechskantmutter Messing CuZn39Pb3, galv. vernickelt Innengewinde metrisch, nach EN 60423 und ISO 724* O zum sicheren Befestigen von Kabelverschraubungen und Zubehörteilen

Mehr

Datenblatt Seitenkanalgebläse Data sheet side channel blowers

Datenblatt Seitenkanalgebläse Data sheet side channel blowers Datenblatt Seitenkanalgebläse Data sheet side channel blowers Serie Series G-BH1 G_200 Seitenkanalgebläse Einphasen-Wechselstrom 50/60 Hz Druckbetrieb Side channel blowers Single-phase current 50/60 Hz

Mehr

Specification. DESIGN Swing check valves for return fl ow prevention in piping systems to be mounted directly between fl anges acc. to DIN.

Specification. DESIGN Swing check valves for return fl ow prevention in piping systems to be mounted directly between fl anges acc. to DIN. Technische Daten BAUFORM Rückschlagklappen zur Rückfl ussverhinderung in Rohrleitungssystemen für den Einbau zwischen DIN Flanschen. ANSCHLUß Flansch DN32 DN500 bemessen für Flansch nach PN16 BETRIEBSDRUCK

Mehr

Electronic Tachometers (Housing Dia., 52 / 80 / 100mm) Elektronische Drehzahlmesser (Gehäuse Ø 52 / Ø80 / Ø100mm)

Electronic Tachometers (Housing Dia., 52 / 80 / 100mm) Elektronische Drehzahlmesser (Gehäuse Ø 52 / Ø80 / Ø100mm) Elektronische Drehzahlmesser (Gehäuse Ø 52 / Ø80 / Ø100mm) Auflichtausführung VDO cockpit international Beschreibung: Analoge Anzeige der Motordrehzahl. Ausführung: Frontring: Deckglas: Einlegering: Zifferblatt:

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GI-50.10 GI-50.10 1 / Hub / stroke = 10mm 110.5 9 68.5 3x M O 0 M6 18 SW5 O50 O6 Magnet bestromt gezeichnet Solenoid illustrated in energised position 6 max. Hub / stroke = 10mm 110.5 39 68.5 3x M O 0

Mehr

Datenblatt Seitenkanalgebläse Data sheet side channel blowers

Datenblatt Seitenkanalgebläse Data sheet side channel blowers Datenblatt Seitenkanalgebläse Data sheet side channel blowers Serie Series G-BH1 G_200 Seitenkanalgebläse Side channel blowers 3 AC; 50/60 Hz 3 AC; 50/60 Hz Vakuumbetrieb Vacuum operation Typen Types 2BH1

Mehr

EUROTEC Namur Solenoid Valve

EUROTEC Namur Solenoid Valve Beschreibung Description - Kolbenschieber-Magnetventil NAMUR, indirekt gesteuert, 5/2- und 3/2-wege, mit Magnetspule und Gerätestecker mit Ausgang M16 für Kabeldurchmesser 5-6mm - Leichtes Umschalten von

Mehr

Drucksensor (1polig über Masse) Pressure Sensor (1-pole common ground) G (Sensor) Nennspannung: 6V bis 24V Verlustleistung: < 250 mw;

Drucksensor (1polig über Masse) Pressure Sensor (1-pole common ground) G (Sensor) Nennspannung: 6V bis 24V Verlustleistung: < 250 mw; Drucksensor (1polig über Masse) Pressure Sensor (1-pole common ground) Technische Daten: Nennspannung: 6V bis 24V Verlustleistung: < 250 mw; Mess-Strom: > 20 ma Betriebstemperatur: 25 C bis + 100 C Widerstandsbereich:

Mehr

Standardausführung standard version. Merkmale. Features

Standardausführung standard version. Merkmale. Features Riegelkurve EMT 17 und EMT 18 Retiring Cam EMT 17 and EMT 18 Standardausführung standard version Merkmale alle Stahlteile verzinkt geräuscharm durch starke Dämpfung beim Ein- und Ausschalten robust und

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 DGV - Datenblätter DGV - Datasheets DGV DGV Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] Drehwinkel Rotary angle [ ] Drehmoment Torque [Ncm] DGV-35.95 35/35 x 27.5 95 DGV-50.95

Mehr

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3

Compressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3 3/2 Wegeventil mit PIEZO-Pilotventil Baureihe P20 3/2 way valve with Piezo-pilot valve Series P20 P20 381RF-* NW 2 Eigenerwärmungsfrei Ein Produkt für alle Ex-Bereiche Kompatibel zu Microcontrollern Kompatibel

Mehr

Induktive Näherungsschalter inductive proximity switches

Induktive Näherungsschalter inductive proximity switches Zylindrisch DC cylindric DC Zylindrisch DC Vollmetall cylindric DC full metal Hochtemperatur high temperature Schweißfest weld resistant Druckfest pressure resistant Analog analog Namur namur AC AC Kunststoff

Mehr

Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung

Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb 25...5000 Impulse pro Umdrehung EEx OG 9 - inkremental Merkmale Drehgeber Inkremental / ATEX /

Mehr

Dokumentation. Druckschalter - Typen DRS..., DRSD..., DRSIP..., DRSO..., DRSS..., DRSSF..., DRSW..., DRSZ..., PE 25, VAKUS... -

Dokumentation. Druckschalter - Typen DRS..., DRSD..., DRSIP..., DRSO..., DRSS..., DRSSF..., DRSW..., DRSZ..., PE 25, VAKUS... - - Typen DRS..., DRSD..., DRSI..., DRSO..., DRSS..., DRSSF..., DRSW..., DRSZ..., E 25, VAKUS... - Stand: 04/08 . Inhalt. Inhaltsverzeichnis....................................................................................................

Mehr

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 280-X / 281-X / 282-X Type 280-X / 281-X / 282-X. fremdgesteuert Modulbauweise

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 280-X / 281-X / 282-X Type 280-X / 281-X / 282-X. fremdgesteuert Modulbauweise fremdgesteuert Modulbauweise Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) externally controlled modular

Mehr

Druckschalter - Transmitter Pressure Switch - Transmitter

Druckschalter - Transmitter Pressure Switch - Transmitter Druckschalter - Transmitter Pressure Switch - Transmitter Druckschalter - Transmitter llfluid - 4 bar Pressure Switch - Transmitter llfluid - 58 si Betriebsannung 8-32VDC Oerating voltage Stromaufnahme

Mehr

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe

Mehr

ASP-1750 HUB-POSITIONIEREINHEIT BETRIEBSDRUCK 4-8 BAR

ASP-1750 HUB-POSITIONIEREINHEIT BETRIEBSDRUCK 4-8 BAR ASP-1750 HUB-POSITIONIEREINHEIT BETRIEBSDRUCK 4-8 BAR LIFTING AND POSITIONING UNIT OPERATING PRESSURE 4-8 BAR TECHNISCHE DATEN ANWENDUNG Die Positioniereinheit ASP-1750 dient zum Indexieren und Positionieren

Mehr

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary

Mehr

Manometerabsperrventile MAV16270; MAV16271; MAV16272 Manometer gauge valves MAV16270; MAV16271; MAV Spindel Edelstahl stem stainless steel

Manometerabsperrventile MAV16270; MAV16271; MAV16272 Manometer gauge valves MAV16270; MAV16271; MAV Spindel Edelstahl stem stainless steel Manometer gage valves MAV16270; MAV16271; MAV16272 MAV16270 Form A Abbildng ggf. abweichend pictre may be different Material material Gehäse Messing body brass Spindel Edelstahl stem stainless steel Überwrfmtter

Mehr