SISTORE CX4 Intelligent digital Video Codec
|
|
- Benedict Kerner
- vor 8 Jahren
- Abrufe
Transkript
1 SISTORE CX4 Intelligent digital Video Codec Inbetriebnahmeanleitung (DE) Startup Manual (EN) Manual de inicio (ES) Manuel de mise en service (FR) Manuale per iniziare (IT) V3.6 Building Technologies Fire Safety & Security Products
2 Data and design subject to change without notice. / Supply subject to availability Copyright by We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
3 SISTORE CX4 Intelligent digital Video Codec Inbetriebnahmeanleitung V3.6 Building Technologies Fire Safety & Security Products
4 Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability Copyright by AG Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte an und wird dieses Dokument nicht ohne unsere vorherige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist. We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him. Warenzeichen SISTORE ist ein Warenzeichen der Fire & Security Products GmbH & Co. ohg. Microsoft ist ein eingetragenes Warenzeichen und Windows ist ein Warenzeichen der Microsoft Corporation. Alle anderen Produkte oder Firmennamen, die namentlich in diesem Handbuch erwähnt werden, dienen nur zum Zwecke der Identifikation oder der Beschreibung und können Warenzeichen oder eingetragene Warenzeichen der jeweiligen Eigentümer sein. Kontaktaufnahme Wenn Sie Fragen oder Anregungen zum Produkt oder zu diesem Dokument haben, wenden Sie sich bitte an Ihre örtliche SIEMENS-Niederlassung. Fire & Security Products GmbH & Co. ohg D Karlsruhe Besuchen Sie uns auch im Internet unter: Schulungen Siemens Fire Safety & Security Products bietet zu allen Produkten die notwendigen Schulungen an. Zu diesem Dokument In dieser Inbetriebnahmeanleitung finden Sie Anweisungen zur Montage und Inbetriebnahme von SISTORE CX4 Geräten. Anweisungen zur Konfiguration und Bedienung finden Sie im Konfigurationshandbuch und im Benutzerhandbuch auf der mitgelieferten CD.
5 Inhalt 1 Sicherheit Zielgruppe Allgemeine Sicherheitshinweise Transport Montage Inbetriebnahme Bedeutung von Signalwörtern Bedeutung der Gefahrensymbole Richtlinien und Normen Technische Daten Bestellangaben Lieferumfang Gerätebeschreibung Anzeigen Anschlüsse Montage Tischbetrieb Rackeinbau Inbetriebnahme Anlagenbetrieb mit einem Gerät Anlagenbetrieb mit mehreren Geräten Ferritkern anbringen IP-Adresse des Client-PCs einstellen Konfiguration Software installieren Software SISTORE CX Config aufrufen SISTORE CX Konfigurationshandbuch aufrufen Entsorgung
6 Sicherheit 1 Sicherheit 1.1 Zielgruppe Die Anweisungen in dieser Dokumentation richten sich an die folgende Zielgruppe: Zielgruppe Qualifikation Tätigkeit Zustand des Produkts Inbetriebsetzer Besitzt Fachkenntnisse im Bereich Gebäudeinstallationstechnik oder Elektroinstallationen. Nimmt das Produkt zum ersten Mal in Betrieb. Produkt ist noch nicht installiert und konfiguriert. 1.2 Allgemeine Sicherheitshinweise Transport Lesen Sie vor der Bedienung des Gerätes die allgemeinen Sicherheitshinweise. Bewahren Sie dieses Dokument zum Nachschlagen auf. Geben Sie dieses Dokument bei der Weitergabe des Produktes mit. Beachten Sie zusätzlich die landesspezifischen oder ortsüblichen Sicherheitsnormen oder Gesetze für die Planung, die Konzeption, die Installation, den Betrieb und die Entsorgung des Produktes. Funkstörungen umliegender Geräte Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen durchzuführen. Haftungsanspruch Schließen Sie das Gerät nur an, wenn es unbeschädigt ist und wenn der Lieferumfang vollständig ist. Nehmen Sie nur Veränderungen am Gerät vor, die in diesem Dokument erwähnt sind oder vom Hersteller genehmigt wurden. Verwenden Sie nur vom Hersteller genehmigte Ersatz- und Zubehörteile. Netzanschluss Verwenden Sie nur das im Lieferumfang enthaltene Steckernetzteil. Verwenden Sie das Steckernetzteil nur mit einem Spannungsversorgungskabel, das für das jeweilige Land zugelassen ist und den landesspezifischen Bestimmungen entspricht. Schließen Sie das Steckernetzteil nur an Stromquellen mit der angegebenen Spannung an. Auf dem Typenschild finden Sie Hinweise zur Spannungsversorgung (siehe Kap. 3: Technische Daten). Geräteschaden bei Transport Bewahren Sie die Verpackung des Gerätes für den Weitertransport auf. Setzen Sie das Gerät keiner Erschütterung aus. 4
7 Sicherheit Montage Kabelschaden durch Belastung Setzen Sie die Kabel keiner Zugbeanspruchung aus. Achten Sie darauf, dass Kabel nicht belastet, geknickt oder beschädigt werden Inbetriebnahme Geräteschaden durch den falschen Standort Halten Sie die vom Hersteller empfohlenen Umgebungsbedingungen ein (siehe Kap. 3: Technische Daten). Betreiben Sie das Gerät nicht in der Nähe einer stark elektromagnetischen Strahlungsquelle. Betreiben Sie das Gerät nicht an staubigen Orten. Verwenden Sie das Gerät nur im Innenbereich. Setzen Sie das Gerät keiner Erschütterung aus. Schützen Sie das Gerät vor Feuchtigkeit und Nässe. Geräteschaden durch unzureichende Belüftung Blockieren Sie nicht die Belüftungsöffnungen des Gerätes. 1.3 Bedeutung von Signalwörtern Auf die Schwere der Gefahr wird mit Signalwörtern hingewiesen. Signalwort VORSICHT WICHTIG Art der Gefahr Gefahr von mittlerer bzw. leichter Körperverletzung oder Sachschaden Gefahr von Funktionsstörungen 1.4 Bedeutung der Gefahrensymbole Die Art der Gefahr wird mit Symbolen dargestellt. Warnung vor einer Gefahrenstelle Warnung vor gefährlicher elektrischer Spannung 5
8 Richtlinien und Normen 2 Richtlinien und Normen Die EG-Richtlinie 2004/108/EC Elektromagnetische Verträglichkeit wird nur mit einem Ferritkern erfüllt (siehe Kap. 8.3: Ferritkern anbringen). Das Produkt erfüllt die Anforderungen der nachfolgenden EG-Richtlinien. Die EG-Konformitätserklärung wird zur Verfügung gestellt bei: Fire & Security Products GmbH & Co. ohg Karlsruhe Deutschland EG-Richtlinie 2004/108/EC Elektromagnetische Verträglichkeit Die Konformität mit der EG-Richtlinie 2004/108/EC wird nachgewiesen durch die Einhaltung folgender Normen: Störaussendung: EN EN Kl. A Störfestigkeit: EN EG-Richtlinie 2006/95/EG Niederspannungsrichtlinie Die Konformität mit der EG-Richtlinie 2006/95/EG wird nachgewiesen durch die Einhaltung folgender Norm: Sicherheit: EN Technische Daten Anwendung SISTORE CX4 SISTORE CX4 250 SISTORE CX4 500 SISTORE CX Senden und Empfangen Senden, Empfangen und Speichern Senden, Empfangen und Speichern Senden, Empfangen und Speichern Betriebsspannung 12 V DC ± 5 % 12 V DC ± 5 % 12 V DC ± 5 % 12 V DC ± 5 % Stromaufnahme (Dauerbetrieb) Stromaufnahme (Spitzen/Anlauf) Umgebungstemperatur (Tmra) Relative Luftfeuchtigkeit % ohne Kondensation 2,0 A 3,0 A 3,5 A 3,5 A 2,5 A 4,0 A 5,0 A 5,0 A 5 40 C 5 40 C 5 40 C 5 35 C % ohne Kondensation % ohne Kondensation % ohne Kondensation Abmessungen (B x H x T) 440 x 45 x 380 mm 440 x 45 x 380 mm 440 x 45 x 380 mm 440 x 45 x 380 mm Gewicht (ohne Netzteil) 4,2 kg 5,0 kg 5,8 kg 5,8 kg 6
9 Bestellangaben 4 Bestellangaben Typ Art.-Nr. Bezeichnung Gewicht SISTORE CX4 S24245-F5056-A2 4 Kameras ohne Festplatte 100 ips 4,2 kg SISTORE CX4 250/100 S24245-F5056-A3 4 Kameras 1 x 250 GB 100 ips 5,0 kg SISTORE CX4 500/100 S24245-F5056-A4 4 Kameras 2 x 250 GB 100 ips 5,8 kg SISTORE CX4 1000/100 S24245-F5056-A6 4 Kameras 2 x 500 GB 100 ips 5,8 kg Zubehör, nicht im Lieferumfang enthalten! CX4 EDS S24245-P5101-A2 EDS Enhanced Detection Solution Bewegungserkennung und Objektverfolgung CX4 ODR P54565-P1-A2 ODR Object Detection/Removal Erkennung zurückgelassener und entfernter Objekte 5 Lieferumfang SISTORE CX4 in der bestellten Ausbauvariante Software CD mit Konfigurationshandbuch und Benutzerhandbuch Inbetriebnahmeanleitung Netzwerkkabel Steckernetzteil mit Spannungsversorgungskabel Winkel für den Rackeinbau Vier Blechschrauben (4,5 x 25) Gummifüße Klappferritkern Typ der Firma Würth 7
10 Gerätebeschreibung 6 Gerätebeschreibung 6.1 Anzeigen LED-Anzeigen beim Starten des Geräts Videostatus pro Kanal (Input) Alle Anzeigen aus: Grünes Lauflicht: Alle Anzeigen rot leuchtend: Anschließen des Gerätes (ca. 30 Sek. nach Inbetriebnahme) oder Gerät betriebsbereit Initialisierung des Gerätes. Prüfen der Festplatte (Kann lange dauern, falls Gerät nicht ordnungsgemäß heruntergefahren wurde) Videoprozessor wird installiert (ca. 12 Sek.) LED-Anzeigen im Online-Zustand 1 Videostatus Anzeige aus: Keine Kamera angeschlossen 2 pro Kanal (Input) rot: Alarm, Initialisierung, Überhitzung 3 grün: Kamerasignal liegt an 4 orange: Live-Bild oder Aufnahme 5 Network Anzeige aus: Keine Verbindung zum Netzwerk grün leuchtend: Verbindung zum Netzwerk grün blinkend: Datenübertragung 6 Hard Disk Anzeige aus: Kein Zugriff auf interne Festplatte/n grün blinkend: Zugriff auf interne Festplatte/n 7 Power grün leuchtend: Stromversorgung LED-Anzeigen in Sonderfällen Videostatus pro Kanal (Input) Alle Anzeigen rot blinkend Alle Anzeigen orange blinkend Orangefarbenes Lauflicht: Alle Anzeigen rot leuchtend: Neuinitialisierung des Gerätes nach Factory Reset (kann lange dauern, falls viele Aufnahmen gespeichert sind). Danach erneuter Bootvorgang Herunterfahren des Geräts nach Reboot. Danach erneuter Bootvorgang. Herunterfahren des Geräts nach Restart. Danach erneuter Bootvorgang. Überhitzung des Gerätes Gerät fährt herunter. Nach Abkühlung erneuter Bootvorgang. 8
11 Gerätebeschreibung 6.2 Anschlüsse 1 4 Videoeingänge Anschluss von 75 Ohm-BNC-Kabel (PAL) 2 4 Abschlusswiderstände On: Videosignal nicht durchschleifen Off: Videosignal zu anderem Videoeingang durchschleifen 3 4 Videoschleifen Anschluss von 75 Ohm-BNC-Kabel 4 2 Videoausgänge Anschluss von 75 Ohm-BNC-Kabel (PAL) 5 4 Digitale Eingänge potential getrennt, 5 bis 24 Volt 6 4 Digitale Ausgänge potential getrennte Open-Collector-Ausgänge, 5 24 V, max. 50 ma 7 Audio Eingänge nicht unterstützt 8 Audio Ausgänge nicht unterstützt 9 USB 1.1 max. 500 ma 10 LAN RJ45 10/100 Mbit-Netzwerkanschluss 11 RS232 Transparenter Datenkanal (nicht parallel zu RS485 nutzbar), Kabellänge: max. 3 m 12 RS485 Transparenter Datenkanal (nicht parallel zu RS232 nutzbar), Kabellänge: max m 13 Netzanschluss 12 V DC, 100 W (nur mitgeliefertes Netzteil verwenden) 14 Typenschild Seriennummer, Model-Bezeichnung, Bestellnummer Pinbelegungen PIN RS232-Stecker RS485-Buchse 1 DCD NC 2 RXD A (TX+/RX+) 3 TXD B (TX-/RX-) 4 DTR NC 5 GND GND 6 DSR NC 7 RTS NC 8 CTS NC 9 RI NC 9
12 Montage 7 Montage 7.1 Tischbetrieb WICHTIG Überhitzung des Gerätes Bei Überhitzung wird das Gerät automatisch heruntergefahren. Alle 4 LEDs an der Vorderseite des Gerätes leuchten rot. 1. Ziehen Sie den Netzstecker und lassen Sie das Gerät abkühlen. 2. Warten Sie mind. 2 Stunden, bis das Gerät abgekühlt ist. 3. Prüfen Sie den Mindestabstand von 85 mm an den Seiten des Gerätes. 4. Prüfen Sie die Umgebungstemperatur. Vergleichen Sie hierzu Kap.: 3 Technische Daten. 5. Stecken Sie den Netzstecker wieder ein. 6. Starten Sie das Gerät erneut. 1. Kleben Sie die beiliegenden Gummifüße in die 4 Einbuchtungen an der Unterseite des Gerätes. 2. Stapeln Sie max. drei Geräte aufeinander. 3. Halten Sie an der linken und rechten Seite des Gerätes einen Mindestabstand von 85 mm ein. 10
13 Montage 7.2 Rackeinbau WICHTIG Überhitzung des Gerätes Bei Überhitzung wird das Gerät automatisch heruntergefahren. Alle 4 LEDs an der Vorderseite des Gerätes leuchten rot. 1. Ziehen Sie den Netzstecker und lassen Sie das Gerät abkühlen. 2. Warten Sie mind. 2 Stunden, bis das Gerät abgekühlt ist. 3. Prüfen Sie den Mindestabstand von 85 mm an den Seiten des Gerätes. 4. Prüfen Sie die Umgebungstemperatur. Vergleichen Sie hierzu Kap.: 3 Technische Daten. 5. Stecken Sie den Netzstecker wieder ein 6. Starten Sie das Gerät erneut. 1. Lösen Sie die Metallschraube (M 4 x 10) und die zwei Blechschrauben (4,5 x 16) an den Geräteseiten. 2. Bewahren Sie die Schrauben auf. 3. Entfernen Sie die weißen Plastikunterlegscheiben. VORSICHT Geräteschaden durch zu lange Schrauben Bei der Verwendung von zu langen Schrauben kann das Gerät beschädigt werden. Verwenden Sie nur die im Lieferumfang enthaltenen Schrauben (4,5 x 25). 4. Schrauben Sie die Eckwinkel mit den zwei mitgelieferten Blechschrauben (4,5 x 25) und der vorhandenen Metallschraube (M 4 x 10) an den Geräteseiten an. Vergleichen Sie dazu Abb Setzen Sie die Käfigmuttern (M 6) zur Gerätebefestigung in die Profilschiene des Racks ein. 6. Befestigen Sie das Gerät mit den vier Schrauben (M 6 x 18) und den Kunststoff-Unterlegscheiben an den Profilschienen des Racks. Vergleichen Sie hierzu Abb. 1. Für gute Belüftung 1. Halten Sie nach jedem dritten bis vierten Gerät eine Höheneinheit (HE) frei. 2. Halten Sie an der linken und rechten Seite des Gerätes einen Mindestabstand von 85 mm ein. Abb. 1 SISTORE CX4 Rackeinbau 11
14 Inbetriebnahme 8 Inbetriebnahme 8.1 Anlagenbetrieb mit einem Gerät Netzwerk-Switch Client-PC 1-4 Kameras SISTORE CX4 Analoger Monitor Abb. 2 Anlagenbetrieb mit einem Gerät Abb. 3 Anschlüsse SISTORE CX4 1. Betreiben Sie das Gerät auf einem Tisch oder in einem Rack. Vergleichen Sie hierzu Kap.: 7.1 Tischbetrieb und Kap.: 7.2 Rackeinbau. 2. Schießen Sie die Kameras (max. 4) an die Videoeingänge (1) an. Falls Durchschleifen erforderlich ist, stellen Sie den Abschlusswiderstand (2) auf Off und schließen Sie weiterführende Videokabel an den Videoschleifen (3) an. 3. Schließen Sie einen analogen Monitor an das Gerät (4) an. 4. Schließen Sie den Client-PC an den Netzwerk-Switch und diesen mit dem Netzwerkkabel an das Gerät (10) an. 5. Schließen Sie das Netzteil zuerst an SISTORE CX4 (13) und danach an die Spannungsversorgung an. 6. Schalten Sie den analogen Monitor ein. Es erscheint nach kurzer Zeit die IP-Adresse des SISTORE CX4. 7. Schließen Sie den Client-PC an die Spannungsversorgung an. 8. Starten Sie den Client-PC. 9. Stellen Sie die IP-Adresse des Client-PCs ein. Vergleichen Sie hierzu Kap.: 8.4 IP-Adresse des Client-PCs einstellen. 12
15 Inbetriebnahme 8.2 Anlagenbetrieb mit mehreren Geräten Netzwerk-Switch 1-4 Kameras SISTORE CX4 Client-PC 1-4 Kameras SISTORE CX4 1-4 Kameras SISTORE CX4 SISTORE CX4 Analoger Monitor Abb. 4 Anlagenbetrieb mit mehreren Geräten Abb. 5 Anschlüsse SISTORE CX4 1. Betreiben Sie das Gerät auf einem Tisch oder in einem Rack. Vergleichen Sie hierzu Kap.: 7.1 Tischbetrieb und Kap.: 7.2 Rackeinbau. 2. Schießen Sie die Kameras (max. 4) an die Videoeingänge (1) an. 3. Falls Durchschleifen erforderlich ist, stellen Sie den Abschlusswiderstand (2) auf Off und schließen Sie weiterführende Videokabel an den Videoschleifen (3) an. 4. Verbinden Sie alle SISTORE Geräte mit dem Netzwerk-Switch (10). 5. Schließen Sie einen oder mehrere Client-PCs mit dem Netzwerkkabel an den Netzwerk-Switch an. 6. Schließen Sie Monitore an die Client-PCs an. 7. Um die IP-Adresse eines SISTORE Gerätes auszulesen, schließen Sie einen analogen Monitor an das entsprechende Gerät (4) an. 8. Schließen Sie das Netzteil zuerst an den SISTORE (13) und danach an die Spannungsversorgung an. 9. Schalten Sie den analogen Monitor ein. Es erscheint nach kurzer Zeit die IP-Adresse des SISTORE CX Schließen Sie den Client-PC an die Spannungsversorgung an. 11. Starten Sie den Client-PC. 12. Stellen Sie die IP-Adresse des Client-PCs ein. Vergleichen Sie hierzu Kap.: 8.4 IP-Adresse des Client-PCs einstellen. 13
16 Inbetriebnahme 8.3 Ferritkern anbringen Die EG-Richtlinie 2004/108/EC Elektromagnetische Verträglichkeit wird nur mit einem Ferritkern erfüllt. Der Klappferritkern Typ der Firma Würth ist im Lieferumfang enthalten. WICHTIG Der Abstand zwischen Ferritkern und Gerät darf max. 100 mm betragen. Falls das verwendete I/O Kabel nicht in den mitgelieferten Klappferritkern passt, verwenden Sie einen anderen Ferritkern mit den entsprechenden elektrischen Eigenschaften. 1. Schließen Sie das I/O Kabel am I/O Anschluss an. Abb. 6 Ferritkern um I/O Kabel 1 I/O Anschluss 2 I/O Kabel 3 Ferritkern 2. Bringen Sie um das I/O Kabel den Ferritkern an. 8.4 IP-Adresse des Client-PCs einstellen Vorraussetzung: Das System ist nicht an einen DHCP-Server angeschlossen Klicken Sie im Windows Start Menü auf Start > Einstellungen > Systemsteuerung > Netzwerkverbindungen. 2. Klicken Sie mit der rechten Maustaste auf die ausgewählte Netzwerkverbindung. 3. Wählen Sie aus dem Kontextmenü den Menüpunkt Eigenschaften. Das Dialogfenster Eigenschaften von Local Area Connection öffnet sich. 4. Wählen Sie ein Internetprotokoll (TCP/IP) aus. 5. Klicken Sie auf die Schaltfläche Eigenschaften. Das Dialogfenster Eigenschaften von Internetprotokoll (TCP/IP) öffnet sich. 6. Aktivieren Sie das Optionsfeld Folgende IP-Adresse verwenden. 7. Geben Sie IP-Adresse xxx.xxx und Subnetzmaske ein. 8. Klicken Sie auf die Schaltfläche OK. 9. Starten Sie Ihren Client-PC neu. Das Gerät ist bereit für die Softwareinstallation. Vergleichen Sie hierzu Kap.: 9.1 Software installieren).
17 Konfiguration 9 Konfiguration 9.1 Software installieren Systemvoraussetzungen für den Client-PC Für den Betrieb der SISTORE CX Software auf dem Client-PC empfehlen wir Ihnen: Prozessor Arbeitsspeicher Freie Festplattenkapazität Betriebssystem Grafikkarte Bildschirmauflösung Farbtiefe Dual Core Prozessor 1 GB 5 GB Windows XP SP2 oder Windows Vista mit Unterstützung für DirectX 8 oder höher min x 768 Pixel 16 Bit oder 32 Bit (24 Bit nicht unterstützt) Software installieren 1. Legen Sie die mitgelieferte CD in das CD-Laufwerk des Client-PCs ein. Das Installationsprogramm wird automatisch gestartet. 2. Folgen Sie den Anweisungen des Installationsprogrammes. Die folgenden Softwareanwendungen werden installiert: SISTORE CX Config SISTORE CX Swap-Out Config SISTORE CX Client Administration Client 3. Starten Sie den Client-PC neu, wenn Sie dazu aufgefordert werden. 15
18 Entsorgung 9.2 Software SISTORE CX Config aufrufen 1. Wählen Sie im Windows Start Menü Start > Programme > SIEMENS Video Software Suite > SISTORE CX Config. Abb. 7 SISTORE Startmenü oder Doppelklicken Sie auf die Desktop-Verknüpfung SISTORE CX Config. 2. Melden Sie sich folgendermaßen an: Benutzername: admin Kennwort: admin Die Software SISTORE CX Config ist aufgerufen. 9.3 SISTORE CX Konfigurationshandbuch aufrufen Weitere Anweisungen zur Konfiguration finden Sie im SISTORE CX Konfigurationshandbuch. 1. Wählen Sie im Windows Start Menü Start > Programme > SIEMENS Video Software Suite > SISTORE CX Konfigurationshandbuch (vgl. Abb. 7) Das SISTORE CX Konfigurationshandbuch ist aufgerufen. 10 Entsorgung Alle Elektro- und Elektronikgeräte sind getrennt vom allgemeinen Hausmüll über dafür staatlich vorgesehene Stellen zu entsorgen. Wenn dieses Symbol eines durchgestrichenen Abfalleimers auf einem Produkt angebracht ist, unterliegt dieses Produkt der europäischen Richtlinie 2002/96/EC. Die sachgemäße Entsorgung und getrennte Sammlung von Altgeräten dienen der Vorbeugung von potenziellen Umwelt- und Gesundheitsschäden. Sie sind eine Voraussetzung für die Wiederverwendung und das Recycling gebrauchter Elektround Elektronikgeräte. Ausführlichere Informationen zur Entsorgung Ihrer Altgeräte erhalten Sie bei Ihrer Kommune, Ihrem Müllentsorgungsdienst oder dem Fachhändler, bei dem Sie das Produkt erworben haben. 16
19
20 Herausgegeben von Fire & Security Products GmbH & Co. ohg D Karlsruhe Copyright by AG Liefermöglichkeiten und technische Änderungen vorbehalten. Gedruckt in der Bundesrepublik Deutschland auf umweltfreundlich chlorfrei gebleichtem Papier. Dokument Nr. A24205-A336-N507 Ausgabe
21 SISTORE CX4 Intelligent digital Video Codec Startup Manual V3.6 Building Technologies Fire Safety & Security Products
22 Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability Copyright by AG Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte an und wird dieses Dokument nicht ohne unsere vorherige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist. We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him. Trademarks SISTORE is a trademark of Fire & Security Products GmbH & Co. ohg. Microsoft is a registered trademark and Windows a trademark of Microsoft Corporation. All other products or company names referred to explicitly in this manual are mentioned only for purposes of identification or description and may be trademarks or registered trademarks of their respective owners. Contacting us If you have questions or suggestions regarding the product or this documentation, please contact your local SIEMENS representative. Fire & Security Products GmbH & Co. ohg D Karlsruhe You can also visit our Web site at: Training courses Siemens Fire Safety & Security Products provides training courses for all products. About this document This Startup Manual contains instructions for installation and setup of SISTORE CX4 devices. For information on configuration and operation please refer to the Configuration Manual and the User Manual on the accompanying CD.
23 Contents 1 Safety Target readers Work safety information Transport Installation Setup Meaning of the written warning notices Meaning of the hazard symbols Directives and standards Technical data Details for ordering Scope of delivery Description of the device LEDs Connections Installation Tabletop operation Rack installation Setup Single-device system Multiple-device system Installing the ferrite core Setting the IP address of the client PC Configuration Installing the software Starting the SISTORE SX/CX Config software Opening the SISTORE SX/CX Configuration Manual Disposal
24 Safety 1 Safety 1.1 Target readers The instructions in this document are designed for the following target readers: Target readers Qualification Activity Condition of the product Operational startup personnel Technical training for building or electrical installations. Puts the product into operation for the first time. The product is not yet installed and configured. 1.2 Work safety information Transport Read the general safety precautions before operating the device. Keep this document for reference. Always pass this document on together with the product. Any national or local safety standards or laws that apply to the development, design, installation, operation or disposal of a product must be adhered to in addition to the instructions in the product documentation. Radio interference with other devices in the environment This is a Class A device. This equipment may cause radio interference in a residential installation. In this case the user is encouraged to perform appropriate measures to correct the interference. Liability claim Do not connect the device if it is damaged or any parts are missing. Do not make any changes or modifications to the device unless they are expressly mentioned in this manual and have been approved by the manufacturer. Use only spare parts and accessories that have been approved by the manufacturer. Power connection Use only the plug-in power supply unit that is included in the delivery. Use the plug-in power supply only in conjunction with a power supply cable that has been approved in your country and complies with the national standards. Connect the plug-in power supply only to power sources with the specified voltage. Voltage supply requirements can be found on the type label (see Section 3: Technical data). Damage during transport Keep the packaging material for future transportation. Do not expose the device to mechanical vibrations or shocks. 4
25 Safety Installation Cable damage due to mechanical load Do not apply tensile force on the cable. Make sure that cables are not under stress, kinked or damaged Setup Damage due to unsuitable mounting location The environmental conditions recommended by the manufacturer must be observed (see Section 3: Technical data). Do not operate the device close to sources of powerful electromagnetic radiation. Do not operate the device in dusty places. The device should only be used for indoor applications. Do not expose the device to mechanical vibrations or shocks. Protect the device against moisture. Damage to the device due to lack of ventilation Do not block or cover the ventilation openings of the device. 1.3 Meaning of the written warning notices The severity of a hazard is indicated by the following written warning notices. Signal word CAUTION IMPORTANT Type of risk There is a risk of minor injuries or damage to property. Malfunctioning may result 1.4 Meaning of the hazard symbols The nature of the hazard is indicated by icons. Caution - Dangerous area! Caution: Dangerous electrical voltage! 5
26 Directives and standards 2 Directives and standards Compliance with the European Directive 2004/108/EC Electromagnetic Compatibility will be achieved only if the device is equipped with a ferrite core (see Section 8.3: Installing the ferrite core). This product complies with the requirements of the following European directives. The EU declaration of conformity is available to the responsible agencies at: Fire & Security Products GmbH & Co. ohg Karlsruhe Germany European Directive 2004/108/EC Electromagnetic Compatibility Compliance with the European Directive 2004/108/EC has been proven by testing according to the following standards: Emitted interference: EN EN Class A Interference resistance: EN European Directive 2006/95/EEC Low-Voltage Directive Compliance with the European Directive 2006/95/EEC has been proven by testing according to the following standard: Safety: EN Technical data Application SISTORE CX4 SISTORE CX4 250 SISTORE CX4 500 SISTORE CX transmission and reception transmission, reception and recording transmission, reception and recording transmission, reception and recording Operating voltage 12 V DC ± 5% 12 V DC ± 5% 12 V DC ± 5% 12 V DC ± 5% Power consumption (continuous operation) Power consumption (peak/startup current) Environmental temperature (TMRA) Relative humidity 20 80% without condensation 2.0 A 3.0 A 3.5 A 3.5 A 2.5 A 4.0 A 5.0 A 5.0 A 5 40 C 5 40 C 5 40 C 5 35 C 20 80% without condensation 20 80% without condensation 20 80% without condensation Dimensions (W x H x D) 440 x 45 x 380 mm 440 x 45 x 380 mm 440 x 45 x 380 mm 440 x 45 x 380 mm Weight (without power supply unit) 4.2 kg 5.0 kg 5.8 kg 5.8 kg 6
27 Details for ordering 4 Details for ordering Type Order No. Designation Weight SISTORE CX4 S24245 F5056 A2 4 cameras without hard drive 100 ips 4.2 kg SISTORE CX4 250/100 S24245 F5056 A3 4 cameras 1 x 250 GB 100 ips 5.0 kg SISTORE CX4 500/100 S24245 F5056 A4 4 cameras 2 x 250 GB 100 ips 5.8 kg SISTORE CX4 1000/100 S24245-F5056-A6 4 cameras 2 x 500 GB 100 ips 5.8 kg Accessories, not included in the delivery! CX4 EDS S24245-P5101-A2 EDS Enhanced Detection Solution Motion detection and object tracking CX4 ODR P54565-P1-A2 ODR Object Detection/Removal Detection of removed or left objects 5 Scope of delivery SISTORE CX4 model as ordered Software CD with configuration manual and user manual Startup manual Network cable Plug-in power supply with power supply cable Bracket for rack installation Four self-tapping screws (4.5 x 25) Rubber feet Snap-on ferrite core type , manufacturer: Würth 7
28 Description of the device 6 Description of the device 6.1 LEDs LED indicators of video status during device startup Video status line per channel (input) All LEDs off: LEDs lighting green in sequence: Connection of the device (approx. 30 sec following initial start-up) or Device is ready for operation Initializing the device Checking the hard disk (this may take quite some time if the device was not shut down properly) All LEDs showing red: The video processor is being installed (approx. 12 sec) LED displays while online 1 Video status No indicator: No camera connected 2 line per channel Red: Alarm, initializing, overheated (input) 3 Green: Receiving camera signal 4 Orange: Live image or recording 5 Network No indicator: No connection to the network Lit green: Connected to the network Blinking green: Data transmission 6 Hard disk No indicator: No access to internal hard drive(s) Blinking green: Access to internal hard drive(s) 7 Power Lit green: Power supply LED indicators in exceptional cases Video status line per channel (input) All LEDs flashing red: All LEDs flashing orange Re-initializing the device following a factory reset (if a large number of recordings are stored on the device this may take quite some time) Then the device boots up again. Device shutting down following a reboot. Then the device boots up again. LEDs lighting orange in sequence: Device shutting down following a restart. Then the device boots up again. All LEDs showing red: Overheating of the device Device shutting down. The device boots up again when it has cooled down. 8
miditech 4merge 4-fach MIDI Merger mit :
miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse
MehrSoftwareupdate-Anleitung // AC Porty L Netzteileinschub
1 Softwareupdate-Anleitung // AC Porty L Netzteileinschub Softwareupdate-Anleitung // AC Porty L Netzteileinschub HENSEL-VISIT GmbH & Co. KG Robert-Bunsen-Str. 3 D-97076 Würzburg-Lengfeld GERMANY Tel./Phone:
MehrKurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen
Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen QuickStart Guide to read a transponder with a scemtec TT reader and software UniDemo Voraussetzung: - PC mit der
MehrInstallation Instructions
EN DE Installation Instructions WLAN Installation Kit, 300 Mbps, 5 GHz, 16 dbi AK-4 Wireless Kit Scope of delivery Junction box AK-4 (1x) 1 Connection board AK-4 CB with 12VDC power supply unit (1x) 2
MehrCABLE TESTER. Manual DN-14003
CABLE TESTER Manual DN-14003 Note: Please read and learn safety instructions before use or maintain the equipment This cable tester can t test any electrified product. 9V reduplicated battery is used in
Mehrp^db=`oj===pìééçêíáåñçêã~íáçå=
p^db=`oj===pìééçêíáåñçêã~íáçå= Error: "Could not connect to the SQL Server Instance" or "Failed to open a connection to the database." When you attempt to launch ACT! by Sage or ACT by Sage Premium for
MehrCameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe
Cameraserver mini commissioning Page 1 Cameraserver - commissioning Contents 1. Plug IN... 3 2. Turn ON... 3 3. Network configuration... 4 4. Client-Installation... 6 4.1 Desktop Client... 6 4.2 Silverlight
Mehrhttps://portal.microsoftonline.com
Sie haben nun Office über Office365 bezogen. Ihr Account wird in Kürze in dem Office365 Portal angelegt. Anschließend können Sie, wie unten beschrieben, die Software beziehen. Congratulations, you have
MehrALL1681 Wireless 802.11g Powerline Router Quick Installation Guide
ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide 1 SET ALL1681 Upon you receive your wireless Router, please check that the following contents are packaged: - Powerline Wireless Router
MehrVN7640 FlexRay/CAN/LIN/Ethernet Interface Quick Start Guide. Version 1.1 English/Deutsch
VN7640 FlexRay/CAN/LIN/Ethernet Interface Quick Start Guide Version 1.1 English/Deutsch Quick Start Guide VN7640 ENGLISH 1 ENGLISH 1.1 Installation Step by Step Procedure Please use the drivers from the
MehrParameter-Updatesoftware PF-12 Plus
Parameter-Updatesoftware PF-12 Plus Mai / May 2015 Inhalt 1. Durchführung des Parameter-Updates... 2 2. Kontakt... 6 Content 1. Performance of the parameter-update... 4 2. Contact... 6 1. Durchführung
MehrUWC 8801 / 8802 / 8803
Wandbedieneinheit Wall Panel UWC 8801 / 8802 / 8803 Bedienungsanleitung User Manual BDA V130601DE UWC 8801 Wandbedieneinheit Anschluss Vor dem Anschluss ist der UMM 8800 unbedingt auszuschalten. Die Übertragung
Mehr300Mbps Wireless Outdoor PoE Access Point/Bridge Quick Installation Guide
LevelOne WAB-5120 300Mbps Wireless Outdoor PoE Access Point/Bridge Quick Installation Guide English Deutsch - 1 - Table of Content English... - 3 - Deutsch... - 9 - This guide covers only the most common
MehrMobiDM-App Handbuch für Windows Mobile
MobiDM-App Handbuch für Windows Mobile Dieses Handbuch beschreibt die Installation und Nutzung der MobiDM-App für Windows Mobile Version: x.x MobiDM-App Handbuch für Windows Mobile Seite 1 Inhalt 1. WILLKOMMEN
MehrUser Manual Bedienungsanleitung. www.snom.com. snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter. English. Deutsch
English snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter Deutsch User Manual Bedienungsanleitung 2007 snom technology AG All rights reserved. Version 1.00 www.snom.com English snom Wireless
MehrUSB Treiber updaten unter Windows 7/Vista
USB Treiber updaten unter Windows 7/Vista Hinweis: Für den Downloader ist momentan keine 64 Bit Version erhältlich. Der Downloader ist nur kompatibel mit 32 Bit Versionen von Windows 7/Vista. Für den Einsatz
MehrRS-232 SERIAL EXPRESS CARD 1-PORT. Expansion 111829
RS-232 SERIAL EXPRESS CARD 1-PORT Expansion 111829 1. Introduction equip RS-232 Serial Express Card works with various types of RS-232 serial devices including modems, switches, PDAs, label printers, bar
MehrGalileo Desktop Benutzerhandbuch Version 1.02
Galileo Desktop Benutzerhandbuch Version 1.02 Galileo Deutschland GmbH. All rights reserved. Dieses Dokument enthält Informationen, an denen Galileo International Rechte besitzt. Dieses Dokument darf nur
MehrE asyline by Hama GmbH & Co KG Postfach 80 86651 Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/502-274 hama@hama.de www.hama.
00021024-10.06 E asyline by Hama GmbH & Co KG Postfach 80 86651 Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/502-274 hama@hama.de www.hama.com Gamepad Thunderstorm II 0021024 l Bedienungsanleitung
MehrCONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP
ANLEITUNGEN // INSTRUCTIONS CONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP BEDIENUNGSANLEITUNG // INSTRUCTION MANUAL MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION KOPPLUNG
MehrEEX Kundeninformation 2007-09-05
EEX Eurex Release 10.0: Dokumentation Windows Server 2003 auf Workstations; Windows Server 2003 Service Pack 2: Information bezüglich Support Sehr geehrte Handelsteilnehmer, Im Rahmen von Eurex Release
Mehr4CH AHD Digital Video Recorder kit
4CH AHD Digital Video Recorder kit with 4x 720P outdoor fixed Lens cameras Quick Installation Guide DN-16120 Connect directly to your DVR Connecting your cameras to your DVR: 1. Find the 60ft. BNC cable,
Mehr150Mbps Micro Wireless N USB Adapter
150Mbps Micro Wireless N USB Adapter TEW-648UBM ŸAnleitung zur Schnellinstallation (1) ŸTroubleshooting (6) 1.11 1. Bevor Sie anfangen Packungsinhalt ŸTEW-648UBM ŸCD-ROM (Dienstprogramm & Bedienungsanleitung)
MehrKURZANLEITUNG. Firmware-Upgrade: Wie geht das eigentlich?
KURZANLEITUNG Firmware-Upgrade: Wie geht das eigentlich? Die Firmware ist eine Software, die auf der IP-Kamera installiert ist und alle Funktionen des Gerätes steuert. Nach dem Firmware-Update stehen Ihnen
MehrEMCO Installationsanleitung Installation instructions
EMCO Installationsanleitung Installation instructions Installationsanleitung Installation instructions Digitalanzeige digital display C40, FB450 L, FB600 L, EM 14D/17D/20D Ausgabe Edition A 2009-12 Deutsch...2
MehrHARD DISK CASING 2.5 STORAGE IDE/PATA TO USB 2.0
STORAGE SUPPORT HARD DISK CASING 2.5 STORAGE IDE/PATA TO USB 2.0 Handbuch SI-707143 STORAGE SUPPORT HARD DISK CASING 2.5 STORAGE IDE/PATA TO USB 2.0 Vielen Dank, dass Sie sich für den Kauf dieses ICIDU
MehrFormatting the TrekStor i.beat run
DE EN Formatting the TrekStor i.beat run Formatierung des TrekStor i.beat run a Beim Formatieren werden ALLE Daten auf dem MP3-Player gelöscht. In diesem Abschnitt wird Ihnen erläutert, wie Sie Ihren MP3-Player
MehrBeleuchteter Spiegel
Beleuchteter Spiegel 00099 00099 00099 0 Artikel Artikelnummer 00099 00099 00099 Maße 80x60 cm 0x80 cm 40x70 cm Teile im Lieferumfang Lieferumfang A B C Spiegel Schrauben Dübel Benötigtes Werkzeug (nicht
MehrDVD MAKER USB2.0 Installation Anleitung
DVD MAKER USB2.0 Installation Anleitung Inhalt V1.0 Kapitel 1: DVD MAKER USB2.0 Hardware Montage...2 1.1 Inhalt der DVD MAKER USB2.0 Paket...2 1.2 Systemanforderungen...2 1.3 Hardware Montage...2 Kapitel
MehrWireless 150N Adapter
Wireless 150N USB Adapter kurzanleitung Modell 524438 INT-524438-QIG-0908-04 Einleitung Vielen Dank für den Kauf des Wireless 150N USB Adapters (Modell 524438) von INTELLINET NETWORK SOLUTIONS. Diese
Mehriid software tools QuickStartGuide iid USB base driver installation
iid software tools QuickStartGuide iid software tools USB base driver installation microsensys Nov 2016 Introduction / Einleitung This document describes in short form installation of the microsensys USB
MehrReadme-USB DIGSI V 4.82
DIGSI V 4.82 Sehr geehrter Kunde, der USB-Treiber für SIPROTEC-Geräte erlaubt Ihnen, mit den SIPROTEC Geräten 7SJ80/7SK80 über USB zu kommunizieren. Zur Installation oder Aktualisierung des USB-Treibers
MehrRelease Notes BRICKware 7.5.4. Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0
Release Notes BRICKware 7.5.4 Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0 Purpose This document describes new features, changes, and solved problems of BRICKware 7.5.4.
MehrProduktinformation Access-Gateway. Product information Access gateway AGW 670-0
Produktinformation Access-Gateway Product information Access gateway AGW 670-0 1 2 3 4 2 Deutsch Anwendung Access-Gateway zur physikalischen Trennung von 2 Netzwerken an einem Access-Server. Durch den
MehrUSB -> Seriell Adapterkabel Benutzerhandbuch
USB -> Seriell Adapterkabel Benutzerhandbuch 1. Produkt Eigenschaften 1 2. System Vorraussetzungen 1 3. Treiber Installation (Alle Windows Systeme) 1 4. Den COM Port ändern 2 5. Einstellen eines RS232
MehrUSB 2.0 PRINTSERVER. Installationsanleitung DN-13006-1
USB 2.0 PRINTSERVER Installationsanleitung DN-13006-1 Bevor Sie beginnen, müssen Sie die folgenden Punkte vorbereiten: Ein Windows-basierter PC mit Printserver Installations-CD Ein Drucker Ein Druckerkabel
MehrDP-101P+ Verpackungsinhalt überprüfen Die folgenden Artikel gehören zum Lieferumfang des DP-101P+:
Dieses Produkt kann mit jedem aktuellen Webbrowser eingerichtet werden (Internet Explorer 5.x, Netscape Navigator 4.x). DP-101P+ Ethernet-Printserver im Taschenformat von D-Link Vor dem Start Sie benötigen
MehrAnleitung zur Schnellinstallation TFM-560X YO.13
Anleitung zur Schnellinstallation TFM-560X YO.13 Table of Contents Deutsch 1 1. Bevor Sie anfangen 1 2. Installation 2 Troubleshooting 6 Version 06.08.2011 1. Bevor Sie anfangen Packungsinhalt ŸTFM-560X
MehrAnleitung zur Schnellinstallation TU3-SA 1.01
Anleitung zur Schnellinstallation TU3-SA 1.01 Table of Contents Deutsch 1 1. Bevor Sie anfangen 1 2. Installation der Hardware 2 3. Zugriff auf die Festplatten des TU3-SA 4 Troubleshooting 5 Version 02.15.2011
MehrTable of Cont 6. 2 General Information... 4 Purpose...4 Documentation...4 Scope of Supply...5 Technical Data Safety Regulations...
2 General Information........................ 4 Purpose........................................4 Documentation................................4 Scope of Supply................................5 Technical
MehrDiese Handbuch wurde erstellt, um Sie durch die Grundlagen Ihres IP Geräts wie Installation und Konfiguration zur Anwendung zu führen.
ZN-S100V Schnelleinrichtungsanleitung Diese Handbuch wurde erstellt, um Sie durch die Grundlagen Ihres IP Geräts wie Installation und Konfiguration zur Anwendung zu führen. Schritt 1: Kabel an das IP-Gerät
MehrGmbH, Stettiner Str. 38, D-33106 Paderborn
Serial Device Server Der Serial Device Server konvertiert die physikalische Schnittstelle Ethernet 10BaseT zu RS232C und das Protokoll TCP/IP zu dem seriellen V24-Protokoll. Damit können auf einfachste
MehrPerceptive Document Composition
Perceptive Document Composition Systemvoraussetzungen Version: 6.1.x Written by: Product Knowledge, R&D Date: October 2015 2015 Lexmark International Technology, S.A. All rights reserved. Lexmark is a
MehrNachdem Sie die Datei (z.b. t330usbflashupdate.exe) heruntergeladen haben, führen Sie bitte einen Doppelklick mit der linken Maustaste darauf aus:
Deutsch 1.0 Vorbereitung für das Firmwareupdate Vergewissern Sie sich, dass Sie den USB-Treiber für Ihr Gerät installiert haben. Diesen können Sie auf unserer Internetseite unter www.testo.de downloaden.
MehrPS3 / PS4 / PC XBOX 360 GAMING HEADSET LX16
PS / PS / PC XBOX 60 GAMING HEADSET LX6 CHAT GAME Content Inhalt Lioncast LX6 gaming headset Lioncast LX6 Gaming Headset Inline remote kabelgebundene Fernbedienung MUTE - MIC - ON XBOX PS PS PC RCA splitter
MehrVIDEO ADAPTER USB 2.0 AUF HDMI. Anleitung zur Schnellinstallation DA-70851
VIDEO ADAPTER USB 2.0 AUF HDMI Anleitung zur Schnellinstallation DA-70851 1. Treiberinstallation Achtung: Schließen Sie den Adapter VOR der Treiberinstallation bitte NICHT am Computer an. Legen Sie die
MehrSymbio system requirements. Version 5.1
Symbio system requirements Version 5.1 From: January 2016 2016 Ploetz + Zeller GmbH Symbio system requirements 2 Content 1 Symbio Web... 3 1.1 Overview... 3 1.1.1 Single server installation... 3 1.1.2
MehrDer Adapter Z250I / Z270I lässt sich auf folgenden Betriebssystemen installieren:
Installationshinweise Z250I / Z270I Adapter IR USB Installation hints Z250I / Z270I Adapter IR USB 06/07 (Laden Sie den Treiber vom WEB, entpacken Sie ihn in ein leeres Verzeichnis und geben Sie dieses
MehrDF PROFI II PC/104-Plus
DF PROFI II PC/104-Plus Installationsanleitung V1.3 04.08.2009 Project No.: 5302 Doc-ID.: DF PROFI II PC/104-Plus COMSOFT d:\windoc\icp\doku\hw\dfprofi ii\installation\pc104+\version_1.3\df profi ii pc
MehrEX-6031. RS-232 zu Ethernet / IP. Bedienungsanleitung. 7. Anschlüsse. 8. Technische Daten. Seriell 9 Pin D-SUB Stecker
7. Anschlüsse Bedienungsanleitung Seriell 9 Pin D-SUB Stecker Pin Signal Pin Signal Pin Signal 1 DCD 4 DTR 7 RTS 2 RXD 5 GROUND 8 CTS 3 TXD 6 DSR 9 DB 9M EX-6031 8. Technische Daten Stromanschluss: 5V
MehrITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.
D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.
Mehrv i r t u A L C O M P o r t s
v i r t u A L C O M P o r t s (HO720 / HO730) Installieren und Einstellen Installation and Settings Deutsch / English Installieren und Einstellen des virtuellen COM Ports (HO720 / HO730) Einleitung Laden
MehrA1 Desktop Security Installationshilfe. Symantec Endpoint Protection 12.1 für Windows/Mac
A Desktop Security Installationshilfe Symantec Endpoint Protection. für Windows/Mac Inhalt. Systemvoraussetzung & Vorbereitung S. Download der Client Software (Windows) S. 4 Installation am Computer (Windows)
MehrInstallation und Start der Software AQ2sp Installation and Start of the software AQ2sp
Installation and Start of the software Abhängig von Ihrer WINDOWS-Version benötigen Sie Administrator-Rechte zur Installation dieser Software. Geeignet für folgende WINDOWS-Versionen: Windows 98 SE Windows
MehrPlease store in a safe place. Bitte sicher aufbewahren.
equinux ID: Password/Passwort: 1 Please store in a safe place. Bitte sicher aufbewahren. English Mac Thank you for choosing an equinux product Your new TubeStick includes The Tube, a modern and convenient
MehrTitelbild1 ANSYS. Customer Portal LogIn
Titelbild1 ANSYS Customer Portal LogIn 1 Neuanmeldung Neuanmeldung: Bitte Not yet a member anklicken Adressen-Check Adressdaten eintragen Customer No. ist hier bereits erforderlich HERE - Button Hier nochmal
MehrInstallation Manual. Driver Installation USB-to-Serial Adapter WE2111. A en/de
Installation Manual English Deutsch Driver Installation USB-to-Serial Adapter WE2111 A4012-1.0 en/de USB-to-Serial Adapter English 2 A4012-1.0 en/de USB-to-Serial Adapter 1 Installation in Windows 7...
MehrTRENDnetVIEW Pro Software. Ÿ Installationsanleitung für TRENDnetVIEW Pro (1)
TRENDnetVIEW Pro Software Ÿ Installationsanleitung für TRENDnetVIEW Pro (1) TRENDnetVIEW Pro/05.29.2014 Inhaltsverzeichnis Anforderungen der Verwaltungssoftware TRENDnetVIEW Pro... 13 Installation von
MehrInstallation Guide WLAN Interface
Installation Guide 7106 7206 7010 WLAN Interface EN Installation Guide This guide explains how to install the Ethernet LAN card in your label printer. You should conult your dealer or distributor for more
MehrProduktinformation _185PNdeen
Produktinformation 201407_185PNdeen Solldaten-UPGRADE Juli 2014 WA 900 / 920 / 020 / 950 / 970 CURA S 800 / 860 / 060 / 900 / 960 WAB01 / WAB 02 CCT CURA R1200 / CURA R2000/ API R2000 BOSCH FWA 51x Auf
MehrDiese Produktinformation enthält neueste Informationen bzw. ergänzt die Angaben im Getting Started und im elektronischen Handbuch.
SIMATIC A5E00148511 01/2002 Box PC 840 Rack PC 840 mit Gleichspannungs-Stromversorgung (24V DC) with DC power supply (24V DC) Produktinformation Product Information Diese Produktinformation enthält neueste
MehrCarMedia. Bedienungsanleitung Instruction manual. AC-Services Albert-Schweitzer-Str.4 68766 Hockenheim www.ac-services.eu info@ac-services.
CarMedia Bedienungsanleitung Instruction manual AC-Services Albert-Schweitzer-Str.4 68766 Hockenheim www.ac-services.eu info@ac-services.eu DE Inhaltsverzeichnis 1. Allgemeine Hinweise... 3 2. CarMedia...
MehrVIDEO CALL CAMERA G-VCAM-01
VIDEO CALL CAMERA G-VCAM-01 EN AUS GUTEM GRUND ENGLISH 07-10 2 SAFETY AND INFORMATION Safety 7 This camera is designed to transmit video and audio signals. All other uses are expressly prohibited. 7 Protect
MehrAnleitung zur Schnellinstallation TU3-S
Anleitung zur Schnellinstallation TU3-S25 1.01 Table of Contents Deutsch 1 1. Bevor Sie anfangen 1 2. Installation der Hardware 2 3. Zugriff auf die Speichergeräte im TU3-S25 4 Troubleshooting 5 Version
MehrElectrical testing of Bosch common rail piezo injectors
Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid
MehrPoE Kit Mounting Instructions SG/XG 210/230/310/330/430/450
PoE Kit Mounting Instructions PoE Kit Mounting Instructions Please note ÌÌ Before installing/removing any LAN module please make sure that the appliance is powered off and power cables are removed. ÌÌ
Mehr1. Double click on the Actisys USB icon Found on Floppy A:\
WARNING:- Make sure that the ACTISYS FIR-USB adapter is not plugged in before installing this Software. ACHTUNG:- Den ACTISYS FIR-USB-Adapter KEINESFALLS vor der Installation der Software anschließen!
MehrWarnung vor der Installation
Warnung vor der Installation Videoserver bei Rauchentwicklung oder komischem Geruch sofort abschalten. Videoserver vor Wasser schützen. Den Videoserver sofort abschalten, wenn er nass geworden ist. Wenden
MehrAnleitung zur Nutzung des SharePort Utility
Anleitung zur Nutzung des SharePort Utility Um die am USB Port des Routers angeschlossenen Geräte wie Drucker, Speicherstick oder Festplatte am Rechner zu nutzen, muss das SharePort Utility auf jedem Rechner
MehrDurametric. Installations Anleitung Quick Installation Guide. Deutsch: Seite 2 bis 3. English: Page 4 to 5. ww.fvd.de
Durametric Quick Installation Guide Deutsch: Seite 2 bis 3 English: Page 4 to 5 w 2 Systemvoraussetzungen: Windows 7 / XP / Vista, (32- und 64-bit) - mind. 1.8GHz Dual Core Prozessor - 1 GB Arbeitsspeicher
Mehr300 MBIT WIRELESS ACCESS POINT ROUTER
300 MBIT WIRELESS ACCESS POINT ROUTER Kurzanleitung zur Installation DN-7059-2 Inhalt Packungsinhalt... Seite 1 Netzwerkverbindungen aufbauen... Seite 2 Netzwerk einrichten... Seite 3 Packungsinhalt Bevor
MehrDatenaustausch@IC RL
Datenaustausch@IC RL SAP cfolders Erste Schritte Erstes Login: Ihre Initial-Zugangsdaten zu SAP cfolders finden Sie im ProjektPortal nach Klick auf den Reiter Projekt SAP cfolders, im Channel SAP cfolders
MehrINSTALLATION DES ETHERNET MODEMS. Inhalt:
INSTALLATION DES ETHERNET MODEMS Inhalt: Seite 2-6 : Hardwareinstallation Seite 7-10: Installation unter Windows XP Seite 11-13: Installation unter Windows 98 Seite 1 von 13 Stand Juni 2003 Hardware-Installation
MehrQuick Start Guide. VN8810 Wireless Interface for CAN/LIN/K Line and DoIP Version 1.0 English / Deutsch
Quick Start Guide VN8810 Wireless Interface for CAN/LIN/K Line and DoIP Version 1.0 English / Deutsch ENGLISH Quick Start Guide VN8810 1 ENGLISH 1.1 Installation Please use the drivers from the included
MehrSmartClass Firmware-Update Vorgehensweise
Benutzeranweisungen SmartClass Firmware-Update Vorgehensweise 2008.01 (V 1.x.x) Deutsch Please direct all enquiries to your local JDSU sales company. The addresses can be found at: www.jdsu.com/tm-contacts
MehrRS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät
Betriebsanleitung RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät ä 2 Operating Instructions RS232 Connection, RXU10 Setting up an RS232 connection
MehrRemotely Anywhere Verwendung von Zertifikaten Schritt für Schritt Anleitung zur Implementation von Zertifikaten in Remotely Anywhere
Remotely Anywhere Verwendung von Zertifikaten Schritt für Schritt Anleitung zur Implementation von Zertifikaten in Remotely Anywhere Copyright 1997-2005 Brainware Consulting & Development AG All rights
MehrEchoLink und Windows XP SP2
EchoLink und Windows XP SP2 Hintergrund Für Computer auf denen Windows XP läuft, bietet Microsoft seit kurzem einen Update, in der Form des Service Pack 2 oder auch SP2 genannt, an. SP2 hat einige neue
MehrGENIUSPRO. Installation Installation des Drucker- Treibers Konfiguration der Software Registrierung SYSTEMVORRAUSSETZUNGEN
1 GENIUSPRO SYSTEMVORRAUSSETZUNGEN PC Pentium Dual-Core inside TM Mind. 2 Gb RAM USB Anschluss 2 GB freier Speicherplatz Bildschirmauflösung 1280x1024 Betriebssystem WINDOWS: XP (SP3), Windows 7, Windows
MehrBenutzer- und Referenzhandbuch
Benutzer- und Referenzhandbuch MobileTogether Client User & Reference Manual All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical,
Mehr(825M) 2-Draht-Sender
Kamera SKS Bussystem 300004 (825M) 2-Draht-Sender 1. Installation Gefahr für Personen durch einen elektrischen Schlag. Verbrennungsgefahr, Geräteschäden und Fehlfunktionen. Bei der Installation sind die
Mehrmmone Internet Installation Windows XP
mmone Internet Installation Windows XP Diese Anleitung erklärt Ihnen in einfachen Schritten, wie Sie das in Windows XP enthaltene VPN - Protokoll zur Inanspruchnahme der Internetdienste einrichten können.
MehrGAMING HEADSET LX16 PRO
GAMING HEADSET LX6 PRO CHAT GAME Content Inhalt Lioncast LX6 Pro gaming headset Lioncast LX6 Pro Gaming Headset Inline remote kabelgebundene Fernbedienung MUTE - MIC - ON XBOX PS PS PC RCA splitter cable
MehrPROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module
LSS PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module The LSS PROFIBUS-DP repeaters 1 to 1 and 1 to 5 are used for coupling up to six PROFIBUS bus segments in RS 485 bus technology.
MehrAnleitung zur Schnellinstallation TFM-PCIV92A B1.21
Anleitung zur Schnellinstallation TFM-PCIV92A B1.21 Table of Contents Deutsch 1 1. Bevor Sie anfangen 1 2. Installation 2 Troubleshooting 6 Version 05.11.2011 1. Bevor Sie anfangen Packungsinhalt ŸTFM-PCIV92A
MehrInstallationsanleitung adsl Privat unter Windows XP
Installationsanleitung adsl Privat unter Windows XP adsl Privat mit Ethernet-Modem unter Windows XP Diese Konfigurationsanleitung erklärt Ihnen in einfachen und bildlich dargestellten Schritten, wie Sie
MehrElectrical tests on Bosch unit injectors
Valid for Bosch unit injectors with order numbers 0 414 700 / 0 414 701 / 0 414 702 Parts Kit Magnet*: - F00H.N37.925 - F00H.N37.933 - F00H.N37.934 * For allocation to the 10-place Bosch order number,
MehrITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.
D Bedienungsanleitung User manual Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. This user manual contains important information for installation and operation.
MehrEG-Konformitätserklärung
EG-Konformitätserklärung Dokument Nr.: GL-11/22/24/08 Hiermit erklären wir, die Firma in alleiniger Verantwortung die Konformität der Produktreihe Servoverstärker SERVOSTAR 300 mit folgenden einschlägigen
MehrDVB-T EuroMini100 Seite 1 von 10
DVB-T EuroMini100 Seite 1 von 10 Kunden Information! Seite Problem 2 Der Sendersuchlauf ist bis 100% durchgelaufen, zeigt aber keine Sender an. Das Gerät hat kein Empfang! 3 Es werden nicht alle Programme
MehrDie Windows-Installation - Schritt für Schritt
Lieferumfang Überprüfen Sie bitte zunächst die Vollständigkeit des von Ihnen erworbenen Pakets. Der Lieferumfang der DMX 6Fire USB umfasst mindestens: 1 DMX 6Fire USB (die Hardware) 1 Netzadapter 1 Adapter
MehrBTD-300 Bluetooth USB-Adapter (Version 3.0)
BTD-300 Bluetooth USB-Adapter (Version 3.0) Windows 8, Windows 7, Vista, XP and Mac OS 10.3.9+ Installations-Kurzanleitung 2012 Kinivo LLC. Alle Rechte vorbehalten. Kinivo ist ein Warenzeichen von Kinivo
MehrYealink W52 DECT IP Telefon
Yealink W52 DECT IP Telefon Manuelle Neukonfiguration Dokumentenversion 1.0 Yealink W52 DECT IP Telefon Mauelle Neukonfiguration Copyright Hinweis Copyright 2016 finocom AG Alle Rechte vorbehalten. Jegliche
MehrHerzlich Willkommen bei der nfon GmbH
efax Handbuch Herzlich Willkommen bei der nfon GmbH Wir freuen uns, Ihnen unser efax vorstellen zu dürfen. Mit dem efax können Sie zu jeder Zeit mit Ihrem Rechner Faxe empfangen. Sie bekommen diese dann
MehrContact 1600 QUICK REFERENCE GUIDE GUIDE D UTILISATION BEDIENUNGSANLEITUNG GUÍA DE REFERENCIA RÁPIDA GUIDA RAPIDA. www.sonybiz.net CHANGING THE WAY
Contact 1600 CHANGING THE WAY QUICK REFERENCE GUIDE GUIDE D UTILISATION BEDIENUNGSANLEITUNG BUSINESS GUÍA DE REFERENCIA RÁPIDA GUIDA RAPIDA COMMUNICATES www.sonybiz.net GB Getting started STEP 1 Turning
MehrEX-6032. 2 x RS-232 zu Ethernet / IP. Bedienungsanleitung. 6. Anschlüsse. 7. Technische Daten. Seriell 9 Pin D-SUB Stecker (Port 1 und 2) :
6. Anschlüsse Bedienungsanleitung Seriell 9 Pin D-SUB Stecker (Port 1 und 2) : Pin Signal Pin Signal Pin Signal 1 CDC 4 DTR 7 RTS 2 RXD 5 GROUND 8 CTS 3 TXD 6 DSR 9 RI DB 9M EX-6032 7. Technische Daten
Mehr5.3.1.12 Lab - Installieren der Software von Drittanbietern unter Windows Vista
5.0 5.3.1.12 Lab - Installieren der Software von Drittanbietern unter Windows Vista Einführung Drucken Sie diese Übung aus und folgen den Anweisungen. In dieser Übung werden Sie Software von Drittanbietern
Mehr