System data sheet BASWA Phon Classic Base. Issued 2017 / 1

Ähnliche Dokumente
System data sheet BASWA Phon Base. Issued 2017 / 1

System data sheet BASWA Phon Classic Fine. Issued 2018/ 1

System data sheet BASWAphon Classic Fine. Issued 2015 / 1

Licht & Akustik.

SWC SPANNLAGER UND GEHÄUSE SWC RADIAL INSERT BALL BEARINGS AND HOUSING

SUREPLAY Multisport. Flexible. At every step. SUREPLAY Workout

Wissen schafft Fortschritt

Registration of residence at Citizens Office (Bürgerbüro)

Silent Gliss. Colorama 1. Acoustic Certificate Zertifikat Akustik

Snap-in switch for switches PSE, MSM and MCS 30

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

The projectivity of the moduli space of stable curves. I: Preliminaries on "det"...

Test Report No

Zehnder CLD. Housing for walls, floors and ceilings

Diese Produktinformation enthält neueste Informationen bzw. ergänzt die Angaben im Getting Started und im elektronischen Handbuch.

Release Notes BRICKware Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0

WALL COVER. by acousticpearls

Test Report No

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

SPINNER MOBILE COMMUNICATION

European BS Standard DIN 8187, Teil 1 ISO

Word-CRM-Upload-Button. User manual

LEISTUNGSERKLÄRUNG. DoP: 0110 für Bewehrungsanschluss mit fischer FIS AB (Mörtel für Bewehrungsanschlüsse) DE

Evidence of Performance

ERHARD is a company of. Datasheet ERHARD ECR check valve

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

Narrow Bandpass Filter

Brand Label. Daimler Brand & Design Navigator

Zöllige Radialrillenkugellager - Sondergrössen Inch Series / Commercial Inch Series.

Outdoor-Tasche. Operating Instructions Bedienungsanleitung GB D

Valid for confirmation of protection type:

Zehnder ComfoWell 220

Grade 12: Qualifikationsphase. My Abitur

USBASIC SAFETY IN NUMBERS

Zehnder ComfoWell 320

Applications. General technical specifications according to ISO Parallelism mm: 5/1x0,10 L3x0,008

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

Data sheet Langfeldkassetten Einhängesystem Long span tiles - hang-in system. Datenblatt KLH-H

Photometric Report 25 Lens Kit

Wie man heute die Liebe fürs Leben findet

Non users after Cochlear Implantation in Single Sided Deafness

Plattenkollektion Panel Collection

Applications. General technical specifications according to ISO Parallelism mm: 5/1x0,10 L3x0,008

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment

EXPOSÉ. Mercedes-Benz 220 Cabriolet A ID 1189

Gipsfaser- und Trockenbauprodukte. Gypsum fibre and dry lining products. Trockenestrich NORIT-TE Dry screed NORIT-TE

ALL1688PC. Benutzerhandbuch. Passiver Powerline Verbindung (Home Plug Gerät) Phasenkoppler (Hutschienen Version)

UV-MASTER. Härtung von Foliendekoroberflächen mit UV-Strahlung UV-Curing of film decorated mold parts (IMD/IML)

Acrylic. 4,3 (Foil break) PMMA layer. Glue line. Profile. Acrylic. 4,4 (Foil break) PMMA layer. Glue line. Profile

Level 2 German, 2015

Kuhnke Technical Data. Contact Details

PONS DIE DREI??? FRAGEZEICHEN, ARCTIC ADVENTURE: ENGLISCH LERNEN MIT JUSTUS, PETER UND BOB

DATENBLATT / FACT SHEET

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Arianna, Weiß, V AC/50-60Hz, 1x max. 80,00 W. Technische Daten.

Level 1 German, 2012

Bestellformel BI 8 F 24 V DC 15 % ED Order specifications Hubmagnet

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Giorgia, Weiß, V AC/50-60Hz, 25,00 W. Technische Daten.

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

Quadt Kunststoffapparatebau GmbH

Summary Details for Performance, Duration and Acoustic Measurements for the. Aircon 10S Wind Turbine. UK MCS Certification Summary

Cart Paths on Golf Courses

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient

Hülsenfreilauf / HF One-way Clutch Bearing

FLACHGLAS / FLAT GLASS. Provetro SCHOTT GLAS / SCHOTT GLASS. Art.-Nr. Code-Nr. Beschreibung BeschreibungDescription Description Maße / Messurements

Datenblatt. Gerade Verschraubung Straight Connector IP 68. A mit montiertem O-Ring Connector body with mounted o-ring B B = Tülle Ferrule

ACDEFG. Hotmetal Borders

Technische Dokumentation Technical Documentation

Brandbook. How to use our logo, our icon and the QR-Codes Wie verwendet Sie unser Logo, Icon und die QR-Codes. Version 1.0.1

Attenuator and Distribution System Zehnder ComfoWell 220

assembly hall Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 10/ 2013

Standard: ÖVE/ÖNORM E Filler/Tape

Test report. Bericht Nr.: PH001/10. Gruppe Physik Seite 1 von 6. Liquisol Mr. Tom Huymans Lindberg Oelegem BELGIUM. Client: Order No.

SOFTWARE UPDATE TOUCHPANEL BY NILAN. So wird die Software für Compact P - GEO/AIR aktualisiert

Level 2 German, 2013

Prüfbericht Nr. / Test Report No: F (Edition 1)

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Cube, Dunkelgrau, V AC/50-60Hz, 1x max. 25,00 W. Technische Daten.

LEISTUNGSERKLÄRUNG. Nr DE. insbesondere Anhänge B 1 bis B 3

Tara-Wood. Specialize in Manufacture of High Quality Solid Wood Flooring. TARA GROUP OF COMPAINES PRICE LIST - Catalogue

a new line of steam sterilizers

-BOO- - F - 24 V DC 100 % ED

Einbau- und Montageanleitung. Assembly and Installation Instructions Spacer ring

Folacoat Diamond. Formate. Rollen. Technische Daten DATENBLATT Charakteristik

Kuhnke Technical Data. Contact Details

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

SWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS

Gehen Sie bei Schienenfahrzeugen auf Nummer Sicher! Play it safe with rail vehicles!

DATENBLATT / FACT SHEET

Device Component: - SIPLUS S DQ 16x110VDC ST TX RAIL Order Nr. 6AG2522-5EH00-4AB0. Breslauer Straße Fürth Deutschland

CA_MESSAGES_ORS_HDTV_IRD_GUIDELINE

SCHOTT-MIROGARD Ein beidseitig interferenzoptisch entspiegeltes, vollkommen transparentes Spezialglas. Es ist in verschiedenen Ausführungen

Verlängerungsschächte VS60, VS 20 und BS 60

s 120; s 311; s 312; s 330; s 510; s 511; s 530; s 700

CA_MESSAGES_ORS_HDTV_IRD_GUIDELINE

DMS für besondere Anwendungen - Hochtemperatur-DMS

EXPOSÉ. Mercedes-Benz 220 Cabriolet A ID 1293

Profiled glass with system

Transkript:

System data sheet BASWA Phon Classic Base Issued 2017 / 1

Contents 1 Application 2 System profile 3 System construction 4 System thicknesses 5 System wights 6 Thermal properties 7 Acoustic system measurement values 8 Installation time 9 Surface protection / Cleaning / Repairs 10 Legal notice / Disclaimer 1 2 2 3 3 3 4 8 8 9 System data sheet BASWA Phon Classic Base www.baswa.com

System data sheet Baswa Phon Classic Base 1 Application For the reduction of the reverberation time in ceilings and wall surfaces. Properties: Excellent broadband sound absorption Minimal installation height Smooth, seamless surface Extensive color selection chart to BASWA colors BC or (individual to NCS / RAL) Non-flammable (A2-s1, d0) according to DIN EN 13501-1 CE certified / ETA-No:16 / 0144 (CSTB) Suitable for processing: Horizontal, inclined or vertical surfaces seamless, straight surfaces up to areas of 500 m 2 (on concrete) and 150 m 2 (on plasterboard, suspended systems, observe specifications of the gypsum industry) Simple vaulted surfaces Double vaults, arches and domes Surfaces with sidelight situations Requirements for the sur face (ceiling / wall): For the adhesion of BASWA Phon systems, the surface must fulfill the following requirements: 1. Must be a mineral, massive or suspended system 2. Must conform to the required final form 3. Must be stable 4. Adhesive strength > 250 N / m 2 (25 kg / m 2 ) 5. Must be airtight 6. Prevention of dew point must be guaranteed System data sheet BASWA Phon Classic Base www.baswa.com 1

Processing conditions: BASWA Phon acoustic systems can only be installed by companies that have been trained by BASWA acoustic AG and are in possession of a BASWA Phon certificate. BASWA acoustic AG only supplies to certified companies.the latest BASWA planning documents as the processing guidelines also apply. 2 System profile Double coat system Grain size of the final coating BASWA Base = 0.7 mm Grain size of the base coating BASWA Base = 0.7 mm Roughest surface structure Standard color ~ NCS S 0500 - N Finish quality Standard <Q2> / maximum <Q3> 3 System construction Massive ceilings 5 Concrete 4 BASWA Fix C, cementious adhesive mortar 3 BASWA Phon acoustic panel 2 BASWA Base base layer Suspended ceilings 1 BASWA Base final layer 5 Plasterboard or Fermacell 4 BASWA Fix K, gypsum adhesive mortar 3 BASWA Phon acoustic panel 2 BASWA Base base layer 1 BASWA Base final layer System data sheet BASWA Phon Classic Base www.baswa.com 2

4 System thicknesses Substrate massive or suspended 5 4 2.0 2.5 mm 3 26, 36, 46, 66 mm 2 1.5 2.5 mm 1 1.5 mm System thicknesses 30 mm 40 mm 50 mm 70 mm 1. BASWA Base final layer 2. BASWA Base layer 3. BASWA Phon acoustic panel 4. Adhesive 5. Substrate 5 System weights From the lower edge of the base: Systemstärke 30 mm ca. 84 N / m2 (8.6 kg / m 2 ) Systemstärke 40 mm ca. 93 N / m2 (9.51 kg / m 2 ) Systemstärke 50 mm ca. 95 N / m2 (9.73 kg / m 2 ) Systemstärke 70 mm ca. 100 N N / m2 (10.17 kg / m 2 ) Note: The weight data can vary depending on the craftsman s processing by ± 15 N / m 2 (± 1.5 kg / m 2 ). 6 Thermal properties BASWA Phon 1 / U U-value (W / m 2 K) λ Lambda-value (W / m K) R (m 2 K / W) Classic Base 30 mm 8 1.47 44 8 40 mm 0.97 3 41 0.97 50 mm 1.25 0 40 1.25 70 mm 1.82 0.55 38 1.82 System data sheet BASWA Phon Classic Base www.baswa.com 3

7 Acoustic system measurement values BASWA Phon Classic Base 30 mm on massive ceilings α w = 5 Sound absorption class C evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0.70 Sound Absorption Average SAA = 0.70 100 0.12 0.15 125 0.12 160 4 200 9 0 250 0.39 315 0.5 400 0.56 0.75 500 8 630 1 800 5 1000 0.92 1250 1 1600 5 0.75 2000 0.79 2500 3150 0.59 0.55 4000 0.51 5000 0.56 BASWA Phon Classic Base 40 mm on massive ceilings α w = 0 Sound absorption class B Frequency, f, f, Hz Hz evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0 Sound Absorption Average SAA = 0 100 0.36 0.35 125 7 160 0.36 200 2 5 250 0.76 315 2 400 6 5 500 9 630 7 800 0.78 0 1000 2 1250 2 1600 4 0 2000 0.79 2500 0.71 3150 5 5 4000 0.59 5000 0.71 System data sheet BASWA Phon Classic Base www.baswa.com 4

BASWA Phon Classic Base 50 mm on massive ceilings α w = 0.75 (L) Sound absorption class C evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0.75 Sound Absorption Average SAA = 0.75 100 7 5 125 3 160 200 0.73 0.70 250 6 315 0.75 400 3 5 500 5 630 8 800 4 0 1000 0.78 1250 0.71 1600 0.79 0.70 2000 0.72 2500 3 3150 6 0 4000 0.53 5000 2 BASWA Phon Classic Base 70 mm on massive ceilings α w = 0 (LM) Sound absorption class C evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0.75 Sound Absorption Average SAA = 0.75 100 3 5 125 0 160 8 200 2 5 250 6 315 4 400 5 5 500 7 630 8 800 4 5 1000 4 1250 8 1600 0.72 5 2000 6 2500 0.58 3150 0.51 0 4000 0.56 5000 0.15 System data sheet BASWA Phon Classic Base www.baswa.com 5

BASWA Phon Classic Base 30 mm suspension, 200 mm α w = 0.75 Sound absorption class C evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0.70 Sound Absorption Average SAA = 0.70 100 0.31 0 125 5 160 5 200 3 5 250 3 315 6 400 2 0.75 500 0.71 630 8 800 5 5 1000 8 1250 8 1600 0.79 0.75 2000 0.72 2500 0.7 3150 2 5 4000 7 5000 0.71 BASWA Phon Classic Base 40 mm suspension, 200 mm α w = 0.95 Sound absorption class A evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 5 Sound Absorption Average SAA = 0.90 100 0.35 0.50 125 3 160 8 200 0.7 0.75 250 1 315 0.93 400 0.92 0.95 500 0.92 630 0 800 9 0 1000 0.97 1250 0.9 1600 1 0.90 2000 0.91 2500 0.95 3150 1.14 0.95 4000 0.91 5000 0.78 System data sheet BASWA Phon Classic Base www.baswa.com 6

BASWA Phon Classic Base 50 mm suspension, 200 mm α w = 5 Sound absorption class C evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0.70 Sound Absorption Average SAA = 0.75 100 0.32 0 125 0.32 160 0.51 200 0.53 0.55 250 0 315 8 400 4 0.90 500 0.93 630 0.94 800 0.92 5 1000 0.73 1250 3 1600 9 0 2000 0.73 2500 5 3150 0.76 0.70 4000 3 5000 9 BASWA Phon Classic Base 70mm suspension, 200 mm α w = 0.75 Sound absorption class C Frequency, f, f, Hz Hz evaluated according to ASTM C423-09a Noise Reduction Coefficient NRC = 0.70 Sound Absorption Average SAA = 0.70 100 0.31 0 125 0.39 160 0.55 200 0.58 5 250 0 315 0.77 400 0 5 500 0.91 630 0.90 800 7 0.70 1000 3 1250 0.74 1600 0.78 0.70 2000 8 2500 0 3150 2 5 4000 0.56 5000 0.71 System data sheet BASWA Phon Classic Base www.baswa.com 7

8 Installation time The installation time given assumes a work group of three to four persons and a ceiling size of 80-100 m 2. The drying times of BASWA Phon jointing and coating materials relate to the atmospheric conditions of the room: 20 C room temperature / 50% relative humidity. Allow each processing step to dry thoroughly, material humidity < 10%. Baswa Phon Classic Base Days 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Glue BASWA Phon acoustic panel Grout BASWA Phon acoustic panel Face grind BASWA Phon acoustic panel Apply BASWA Base base layer Face grind BASWA Base base layer Apply BASWA Base final layer Drying Drying Drying Follow-up work 9 Surface protection / Cleaning / Repairs See BASWA planning documents www.baswa.com System data sheet BASWA Phon Classic Base www.baswa.com 8

10 Legal notice / Disclaimer The present information, and in particular the suggestions for processing and application of our products, are Resilient on our knowledge and experience in normal cases, providing that the products are properly stored, handled and applied. Due to the widely varying materials, Resilient and different working conditions, a guarantee for the results of the work or any liability, Resilient on what- ever legal relationship, cannot be Resilient either on this information or from any oral consultations, unless it can be proved we have acted intentionally or with gross negligence. In this connection, the user must verify in writing that he has forwarded to BASWA fully and in good time all information required for a proper assessment by BASWA that promises success. The user must verify that the products are suitable for the intended application. Product specifications are subject to change without notice. Property rights of third parties must be observed. Additionally, our relevant terms and conditions of sale are valid. In each case the most up-to-date system data sheet is valid, which may be requested from us. All rights reserved. Changes, reprints and photomechanical, as well as electronic, reproduction, even in excerpts, require the explicit permission from BASWA acoustic AG. BASWA acoustic AG Marmorweg 10 CH-6283 Baldegg T +41 (0)41 914 02 22 F +41 (0)41 914 02 20 info@baswa.com www.baswa.com System data sheet BASWA Phon Classic Base www.baswa.com 9