Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogues, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details Kuhnke sales and service in North America Ellis/Kuhnke Controls 13 Lewis Street Unit A-, Eatontown NJ 0774 USA T: (00) 1 0714 T: (73) 91 3334 F: (73) 91 14 Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.
HM 7 HM 7 Bestellformel HM 1 07 F 4 V DC 0 % ED Order specifications Hubmagnet Größe HM 1 Linear solenoid Sizes Bauart Zugmagnet mit Konusanker Stoßmagnet mit Konusanker 07 7 Design type Pull type solenoid with conical face armature Thrust type solenoid with conical face armature Anschlußart Coil terminals Litze (Standardlänge cm) F Flying leads ( cm standard length) Nennspannung (Standardspannung) 1) 4 Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 60 V DC lieferbar 1) Other voltages are available on request up to 60 V DC Gewicht: Magnet: ca. 3 g Anker: ca. g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 B 7 Prüfspannung: 00 V (eff) Schutzart: IP 00 HM 1 7 - F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 3 g appr. g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 B 7 Test voltage: 00 V (eff) Protection: IP 00 Zul. rel. Einschaltdauer (ED) ) % 0 70 4 1 % Perm. duty cycle (ED) ) Nennaufnahme P W, 4,3 6, 1 W Nominal coil power P Anzugszeit (ED) 3) ms 34 ms Actuation time (ED) 3) ) Bei Montage auf eine Kühlfläche von mindestens cm ist die 1,3fache ED zulässig 3) Bei mm Hub F [N] ) If solenoid is mounted directly onto a flat metal surface of at least cm, the duty cycle can be extended up to 1.3 x nominal rating 3) Stroke mm 6 %ED 3 Kraft-Weg-Diagramm F = f (s) 1 Force vs. Stroke diagramm F = f (s) 0, Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0,3 0, 0,1 0,0 0,06 0 1 3 4 6 7 S [mm] 1 4 70 0 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 4 Main catalogue
HM 7 HM 7 Zugmagnet HM 7 Series HM 7 pull type solenoid Ø, 0, Ø6 11, 1 3 3, 4, 9 16 Stoßmagnet HM 17 Series HM 17 thrust type solenoid 0, 11, Ø6 Ø, M 1 3 ±0,3 16, 16 9 Magnet Hauptkatalog Main catalogue
HM 7 HM 7 Bestellformel HM 07 F 4 V DC 0 % ED Order specifications Hubmagnet Größe HM Linear solenoid Sizes Bauart Zugmagnet mit Konusanker Stoßmagnet mit Konusanker 07 7 Design type Pull type solenoid with conical face armature Thrust type solenoid with conical face armature Anschlußart Coil terminals Litze (Standardlänge cm) F Flying leads ( cm standard length) Nennspannung (Standardspannung) 1) 4 Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 60 V DC 1) Other voltages are available on request up to lieferbar 60 V DC Gewicht: Magnet: ca. 67 g Anker: ca. 1 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 B 7 Prüfspannung: 00 V (eff) Schutzart: IP 00 HM 7 - F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 67 g appr. 1 g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 B 7 Test voltage: 00 V (eff) Protection: IP 00 Zul. rel. Einschaltdauer (ED) ) % 0 60 3 1 % Perm. duty cycle (ED) ) Nennaufnahme P W 4, 7,9 1, 19 39 4 69 W Nominal coil power P Anzugszeit (ED) 3) ms 9 9 ms Actuation time (ED) 3) ) Bei Montage auf eine Kühlfläche von mindestens 4 cm ist die 1,3fache ED zulässig 3) Bei mm Hub Kraft-Weg-Diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand ) If solenoid is mounted directly onto a flat metal surface of at least 4 cm, the duty cycle can be extended up to 1.3 x nominal rating 3) Stroke mm %ED 6 4 3 Force vs. Stroke diagramm F = f (s) F [N] 1 0,7 0, 0,3 0, 0,1 0 4 6 S [mm] 1 3 60 0 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 6 Main catalogue
HM 7 HM 7 Zugmagnet HM 7 Series HM 7 pull type solenoid M4 0, Ø Ø6, 1 0 Ø 3, 63, 1 Stoßmagnet HM 7 Series HM 7 thrust type solenoid M4 0, 1 Ø6, 6 Ø 0, ±0,3 1, 77, Magnet Hauptkatalog 7 Main catalogue
HU 4 HU 4 Bestellformel HU 4 0 F 4 V DC 0 % ED Order specifications Hubmagnet Größe HU 4 Linear solenoid Sizes Bauart Zugmagnet Stoßmagnet 0 4 Design type Pull type solenoid Thrust type solenoid Anschlußart Coil terminals Litze (Standardlänge cm) Flachstecker (Faston; optional) Nennspannung (Standardspannung) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) F A 4 0 % ED Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) 1) Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 60 V DC 1) Other voltages are available on request up to lieferbar 60 V DC Gewicht: Magnet: ca. 7 g Anker: ca. g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 C 10 Prüfspannung: 00 V (eff) Schutzart: IP 00 HU 40 - F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 7 g appr. g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 C 10 Test voltage: 00 V (eff) Protection: IP 00 Zul. rel. Einschaltdauer (ED) ) % 0 40 1 % Perm. duty cycle (ED) ) Nennaufnahme P W,9 6,7 11 1 44 W Nominal coil power P Anzugszeit (ED) 3) ms 14 ms Actuation time (ED) 3) ) Bei Montage auf eine Kühlfläche von mindestens 0 cm ist die 1,3fache ED zulässig 3) Bei 4 mm Hub Kraft-Weg-Diagramm F = f (s) %ED F [N] 4 3 1 0,7 0, 1 40 ) If solenoid is mounted directly onto a flat metal surface of at least 0 cm, the duty cycle can be extended up to 1.3 x nominal rating 3) Stroke 4 mm Force vs. Stroke diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0,3 0, 0,1 0 1 3 4 6 S [mm] 0 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog Main catalogue
HU 4 HU 4 Zugmagnet HU 40 Series HU 40 pull type solenoid Ø6 9 14 16 7 Ø 17, 3, 4 33 0, Stoßmagnet HU 44 Series HU 44 thrust type solenoid 0, 16 14 9 7 17, Ø6 4 40 1 ±0,3 M Magnet Hauptkatalog 9 Main catalogue
HU 3 HU 3 Bestellformel HU 3 0 F 4 V DC 0 % ED Order specifications Hubmagnet Größe HU 3 Linear solenoid Sizes Bauart Zugmagnet Stoßmagnet 0 4 Design type Pull type solenoid Thrust type solenoid Anschlußart Coil terminals Litze (Standardlänge cm) Flachstecker (Faston; optional) Nennspannung (Standardspannung) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) F A 4 0 % ED Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) 1) Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis V DC 1) Other voltages are available on request up to lieferbar V DC Gewicht: Magnet: ca. g Anker: ca. 11 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 B Prüfspannung: 0 V (eff) Hohe Lebensdauer durch Ankerlagerung im Kunststoffspulenkörper HU 34 - F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. g appr. 11 g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 B Test voltage: 0 V (eff) Long life expectancy through plastic bobbin armature bearing Zul. rel. Einschaltdauer (ED) ) % 0 40 1 % Perm. duty cycle (ED) ) Nennaufnahme P W 4, 16 64 W Nominal coil power P Anzugszeit (ED) ms 17 6 ms Actuation time (ED) ) Bei Montage auf eine Kühlfläche von mindestens 0 cm ist die 1,3fache ED zulässig Kraft-Weg-Diagramm F = f (s) %ED F [N] 4 1 0, 1 ) If solenoid is mounted directly onto a flat metal surface of at least 0 cm, the duty cycle can be extended up to 1.3 x nominal rating Force vs. Stroke diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0, 0,3 0, 0,1 0 1 3 4 6 7 S [mm] 40 0 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 60 Main catalogue
HU 3 HU 3 Zugmagnet HU 3 Series HU 3 pull type solenoid Ø 16 1 6 0, Ø 1 1 3, 41 3 Stoßmagnet HU 34 Series HU 34 thrust type solenoid 1 16 6 0, 1 1 Ø 3 1 ±0,3 4 Magnet Hauptkatalog 61 Main catalogue
Magnet Hauptkatalog 6 Main catalogue
e H Solenoids Series H
H H Bestellformel H 06 F 4 V DC 0 % ED Order specifications Hubmagnet Größe H Linear solenoid Sizes Bauart Zugmagnet mit Flachanker Zugmagnet mit Konusanker 1) Stoßmagnet mit Flachanker 03 06 43 Design type Pull type solenoid with flat face armature Pull type solenoid with conical face armature 1) Thrust type solenoid with flat face armature Stoßmagnet mit Konusanker 1) Anschlußart Litze (Standardlänge cm) Flachstecker (optional) Nennspannung (Standardspannung) ) Zulässige relative Einschaltdauer bei Luftkühlung 1) Nur bei Gleichstrom ) Die Magnete sind auf Anfrage bis V DC lieferbar 46 F A 4 Thrust type solenoid with conical face armature 1) Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Only available for DC ) Other voltages are available on request up to V DC Gewicht: Magnet: ca. 6 g Anker: ca. 13 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: VDE 01 B 7 Prüfspannung: 0 V (eff) Hohe Lebensdauer durch Ankerlagerung im Kunststoffspulenkörper. In Sonderausführung ist dieser Magnet auch mit wartungsfreier Ankerlagerung (DU-Lager) für höchste Lebensdauer lieferbar. H46-F 4 V DC 0%ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 6 g appr. 13 g 4 V DC cm B (max. permissible temperature = 1 C) Insulation group according to: VDE 01 B 7 Test voltage: 0 V (eff) Long life expectancy through plastic bobbin armature bearing. The solenoid can also be supplied as special specification with service-free DU armature bearing for maximum durability. Zul. rel. Einschaltdauer (ED) 3) % 0 4 1 % Perm. duty cycle (ED) 3) Nennaufnahme P W,, 19 9, 7 W Nominal coil power P Anzugszeit (ED) ms 4 7 ms Actuation time (ED) 3) Bei Montage auf eine Kühlfläche von mindestens 4 cm ist die 1,3fache ED zulässig 3) If solenoid is mounted directly onto a flat metal surface of at least 4 cm, the duty cycle can be extended up to 1.3 x nominal rating %ED Kraft-Weg-Diagramm F = f (s) Konusanker Flachanker Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 7 4 3 F [N] 1 0, 0, 0,1 0 1 3 4 S [mm] 1 1 4 0 4 0 Force vs. Stroke diagramm F = f (s)6 Conical face armature Flat face armature Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 64 Main catalogue
H H Zugmagnet H 3/6 Series H 3/6 pull type solenoid 4, 0, 3 1 Ø 3, 1 Ø Stoßmagnet H 43/46 Series H 43/46 thrust type solenoid 3 64, 0,, 0,3 1 1 1 M 4 (M ) Magnet Hauptkatalog 6 Main catalogue
H 4 H 4 Bestellformel H 4 06 F 4 V DC 0 % ED Order specifications Hubmagnet Größe H 4 Linear solenoid Sizes Bauart Zugmagnet mit Flachanker Zugmagnet mit Konusanker 1) Stoßmagnet mit Flachanker 03 06 43 Design type Pull type solenoid with flat face armature Pull type solenoid with conical face armature 1) Thrust type solenoid with flat face armature Stoßmagnet mit Konusanker 1) Anschlußart Litze (Standardlänge cm) Flachstecker (optional) Nennspannung (Standardspannung) ) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 1) Nur bei Gleichstrom ) Die Magnete sind auf Anfrage bis V DC lieferbar 46 F A 4 Thrust type solenoid with conical face armature 1) Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Only available for DC ) Other voltages are available on request up to V DC Gewicht: Magnet: ca. g Anker: ca. g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: VDE 01 B 7 Prüfspannung: 0 V (eff) Hohe Lebensdauer durch Ankerlagerung im Kunststoffspulenkörper. H446-F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. g appr. g 4 V DC cm B (max. permissible temperature = 1 C) Insulation group according to: VDE 01 B 7 Test voltage: 0 V (eff) Long life expectancy through plastic bobbin armature bearing. Zul. rel. Einschaltdauer (ED) 3) % 0 70 4 1 % Perm. duty cycle (ED) 3) Nennaufnahme P W 6 9,1 13, 3 40 W Nominal coil power P Anzugszeit (ED) ms 3 9 ms Actuation time (ED) 3) Bei Montage auf eine Kühlfläche von mindestens 60 cm ist die 1,3fache ED zulässig 3) If solenoid is mounted directly onto a flat metal surface of at least 60 cm, the duty cycle can be extended up to 1.3 x nominal rating 0 %ED 40 Kraft-Weg-Diagramm F = f (s) Konusanker Flachanker Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 0, 1 0,6 0,4 0,3 0 4 6 S [mm] 1 1 4 0 70 7 0 0 Force vs. Stroke diagramm F = f (s) Conical face armature Flat face armature Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 66 Main catalogue
H 4 H 4 Zugmagnet H 403/406 Series H 403/406 pull type solenoid 9 0, 40 4 4 0, 14 Ø6, Ø 3 3 Stoßmagnet H 443/446 Series H 443/446 thrust type solenoid 40 66,, 0,3 4 0, 14 Ø Ø6, Magnet Hauptkatalog 67 Main catalogue
H 3 H 3 Bestellformel H 3 06 F 4 V DC 0 % ED Order specifications Hubmagnet Größe H 3 Linear solenoid Sizes Bauart Zugmagnet mit Flachanker Zugmagnet mit Konusanker 1) Stoßmagnet mit Flachanker 03 06 43 Design type Pull type solenoid with flat face armature Pull type solenoid with conical face armature 1) Thrust type solenoid with flat face armature Stoßmagnet mit Konusanker 1) Anschlußart Litze (Standardlänge cm) Flachstecker (optional) Nennspannung (Standardspannung) ) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 1) Nur bei Gleichstrom ) Die Magnete sind auf Anfrage bis V DC lieferbar 46 F A 4 Thrust type solenoid with conical face armature 1) Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Only available for DC ) Other voltages are available on request up to V DC Gewicht: Magnet: ca. 90 g Anker: ca. 17 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: VDE 01 C 36 Prüfspannung: 0 V (eff) Hohe Lebensdauer durch Ankerlagerung im Kunststoffspulenkörper. In Sonderausführung ist dieser Magnet auch mit wartungsfreier Ankerlagerung (DU-Lager) für höchste Lebensdauer lieferbar. H346-F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 90 g appr. 17 g 4 V DC cm B (max. permissible temperature = 1 C) Insulation group according to: VDE 01 C 36 Test voltage: 0 V (eff) Long life expectancy through plastic bobbin armature bearing. The solenoid can also be supplied as special specification with service-free DU armature bearing for maximum durability. Zul. rel. Einschaltdauer (ED) 3) % 0 0 16 6 % Perm. duty cycle (ED) 3) Nennaufnahme P W, 9,6 1,, 71 W Nominal coil power P Anzugszeit (ED) ms 1 ms Actuation time (ED) 3) Bei Montage auf eine Kühlfläche von mindestens 70 cm ist die 1,3fache ED zulässig 3) If solenoid is mounted directly onto a flat metal surface of at least 70 cm, the duty cycle can be extended up to 1.3 x nominal rating %ED Kraft-Weg-Diagramm F = f (s) Konusanker Flachanker Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 6 4 3 F [N] 1 0, 0,6 0,4 0,3 0, 0,1 0 1 3 4 S [mm] 6 16 6 0 16 0 0 0 Force vs. Stroke diagramm F = f (s) Conical face armature Flat face armature Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 6 Main catalogue
H 3 H 3 Zugmagnet H 33/36 Series H 33/36 pull type solenoid 4, ±0,, 9 Ø 3 17 6 4 1 Ø3 Stoßmagnet H 343/346 Series H 343/346 thrust type solenoid, 7, ±0,3 17 6 1 Ø 1 Magnet Hauptkatalog 69 Main catalogue
H 34 H 34 Bestellformel H 34 06 F 4 V DC 0 % ED Order specifications Hubmagnet Größe H 34 Linear solenoid Sizes Bauart Zugmagnet mit Flachanker Zugmagnet mit Konusanker 1) Stoßmagnet mit Flachanker 03 06 43 Design type Pull type solenoid with flat face armature Pull type solenoid with conical face armature 1) Thrust type solenoid with flat face armature Stoßmagnet mit Konusanker 1) Anschlußart Litze (Standardlänge cm) Flachstecker (optional) Nennspannung (Standardspannung) ) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 1) Nur bei Gleichstrom ) Die Magnete sind auf Anfrage bis V DC lieferbar 46 F A 4 Thrust type solenoid with conical face armature 1) Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Only available for DC ) Other voltages are available on request up to V DC Gewicht: Magnet: ca. 140 g Anker: ca. 3 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: VDE 01 1, KV/3 Prüfspannung: 0 V (eff) Hohe Lebensdauer durch Ankerlagerung im Kunststoffspulenkörper. In Sonderausführung ist dieser Magnet auch mit wartungsfreier Ankerlagerung (DU-Lager) für höchste Lebensdauer lieferbar. H3406-F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 140 g appr. 3 g 4 V DC cm B (max. permissible temperature = 1 C) Insulation group according to: VDE 01 1. KV/3 Test voltage: 0 V (eff) Long life expectancy through plastic bobbin armature bearing. The solenoid can also be supplied as special specification with service-free DU armature bearing for maximum durability. Zul. rel. Einschaltdauer (ED) 3) % 0 3 1 % Perm. duty cycle (ED) 3) Nennaufnahme P W 3 7 144 W Nominal coil power P Anzugszeit (ED) ms 4 16 ms Actuation time (ED) 3) Bei Montage auf eine Kühlfläche von mindestens 0 cm ist die 1,3fache ED zulässig 3) If solenoid is mounted directly onto a flat metal surface of at least 0 cm, the duty cycle can be extended up to 1.3 x nominal rating Kraft-Weg-Diagramm F = f (s) Konusanker Flachanker Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 0 7 1 0, 0, 0,1 0 4 6 1 S [mm] %ED 1 3 0 Force vs. Stroke diagramm F = f (s) Conical face armature Flat face armature Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 70 Main catalogue
H 34 H 34 Zugmagnet H 3403/3406 Series H 3403/3406 pull type solenoid 9 60 ±0, 49, 4 3 9 1 Ø1 3 6 Ø3 Stoßmagnet H 3443/3446 Series H 3443/3446 thrust type solenoid 76,9 49, 6 ±0,3 6 3 9 1 Ø1 Magnet Hauptkatalog 71 Main catalogue
H 4 H 4 Bestellformel H 4 06 F 4 V DC 0 % ED Order specifications Hubmagnet Größe H 4 Linear solenoid Sizes Bauart Zugmagnet mit Flachanker Zugmagnet mit Konusanker 1) Stoßmagnet mit Flachanker 03 06 43 Design type Pull type solenoid with flat face armature Pull type solenoid with conical face armature 1) Thrust type solenoid with flat face armature Stoßmagnet mit Konusanker 1) Anschlußart Litze (Standardlänge cm) Flachstecker (optional) Nennspannung (Standardspannung) ) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 1) Nur bei Gleichstrom ) Die Magnete sind auf Anfrage bis V DC lieferbar 46 F A 4 Thrust type solenoid with conical face armature 1) Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Only available for DC ) Other voltages are available on request up to V DC Gewicht: Magnet: ca. 14 g Anker: ca. g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 C 36 Prüfspannung: 0 V (eff) H46-F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 14 g appr. g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 C 36 Test voltage: 0 V (eff) Zul. rel. Einschaltdauer (ED) 3) % 0 40 1 % Perm. duty cycle (ED) 3) Nennaufnahme P W 6, 16 6 39 9 W Nominal coil power P Anzugszeit (ED) ms 4 9 ms Actuation time (ED) 3) Bei Montage auf eine Kühlfläche von mindestens 0 cm ist die 1,3fache ED zulässig 3) If solenoid is mounted directly onto a flat metal surface of at least 0 cm, the duty cycle can be extended up to 1.3 x nominal rating Kraft-Weg-Diagramm F = f (s) Konusanker Flachanker Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 60 %ED 0 F [N] 3 1 0, 0, 0 1 3 4 6 7 S [mm] 1 40 40 0 Force vs. Stroke diagramm F = f (s) Conical face armature Flat face armature Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 7 Main catalogue
H 4 H 4 Zugmagnet H 43/46 Series H 43/46 pull type solenoid 4 ±0, 36 9 3 Ø 3 34 17 1 4 1 Ø3 Stoßmagnet H 443/446 Series H 443/446 thrust type solenoid 36, ±0,3 3 34 17 1 1 1 Magnet Hauptkatalog 73 Main catalogue
H 6 H 6 Bestellformel H 6 06 F 4 V DC 0 % ED Order specifications Hubmagnet Größe H 6 Linear solenoid Sizes Bauart Zugmagnet mit Flachanker Zugmagnet mit Konusanker 1) Stoßmagnet mit Flachanker 03 06 43 Design type Pull type solenoid with flat face armature Pull type solenoid with conical face armature 1) Thrust type solenoid with flat face armature Stoßmagnet mit Konusanker 1) Anschlußart Litze (Standardlänge cm) Flachstecker (optional) Nennspannung (Standardspannung) ) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 1) Nur bei Gleichstrom ) Die Magnete sind auf Anfrage bis V DC lieferbar 46 F A 4 Thrust type solenoid with conical face armature 1) Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nominal voltage (standard voltage) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Only available for DC ) Other voltages are available on request up to V DC Gewicht: Magnet: ca. 3 g Anker: ca. 4 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 C 10 Prüfspannung: 0 V (eff) Hohe Lebensdauer durch Ankerlagerung im Kunststoffspulenkörper. In Sonderausführung ist dieser Magnet auch mit wartungsfreier Ankerlagerung (DU-Lager) für höchste Lebensdauer lieferbar. H66-F 4 V DC 0% ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 3 g appr. 4 g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 C 10 Test voltage: 0 V (eff) Long life expectancy through plastic bobbin armature bearing. The solenoid can also be supplied as special specification with service-free DU armature bearing for maximum durability. Zul. rel. Einschaltdauer (ED) 3) % 0 0 1 % Perm. duty cycle (ED) 3) Nennaufnahme P W 11 33 0 1 W Nominal coil power P Anzugszeit (ED) ms 4 16 ms Actuation time (ED) 3) Bei Montage auf eine Kühlfläche von mindestens 160 cm ist die 1,3fache ED zulässig 3) If solenoid is mounted directly onto a flat metal surface of at least 160 cm, the duty cycle can be extended up to 1.3 x nominal rating Kraft-Weg-Diagramm F = f (s) Konusanker Flachanker Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0 %ED 0 60 0 F [N] 4 3 1 0, 0 1 S [mm] 1 0 0 0 Force vs. Stroke diagramm F = f (s) Conical face armature Flat face armature Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 74 Main catalogue
H 6 H 6 Zugmagnet H 63/66 Series H 63/66 pull type solenoid 63 ±0, 0 Ø13, 1 4 7 34 44 7 3 Ø4 Stoßmagnet H 643/646 Series H 643/646 thrust type solenoid, 0, ±0, 34 44 7 3 1 M4 7 Ø13 Magnet Hauptkatalog 7 Main catalogue
Magnet Hauptkatalog 76 Main catalogue
e UH, HR, HL Solenoids Series UH, HR, HL
HR 1 Stoßende Ausführung HR 1 Thrust type Bestellformel HR 1 F 4 V DC 0 % ED Order specifications Hubmagnet Bauart HR 1 Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Flachstecker (optional) F A Coil terminals Flying leads ( cm standard length) Push-on connector (optional) Nennspannung (Standardspannung) 1) 4 Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis 60 V DC lieferbar 1) Other voltages are available on request up to 60 V DC Gewicht: Magnet: ca. 1 g Anker: ca., g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: VDE 01 C 7 Prüfspannung: 00 V (eff) HR1-F-4VDC 0%ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 1 g appr.. g 4 V DC cm B (max. permissible temperature = 1 C) Insulation group according to: VDE 01 C 7 Test voltage: 00 V (eff) Zul. rel. Einschaltdauer (ED) ) % 0 40 1 7 % Perm. duty cycle (ED) ) Nennaufnahme P W 9 14 W Nominal coil power P ) Bei Montage auf eine Kühlfläche von mindestens 160 cm ist die 1,3fache ED zulässig ) If solenoid is mounted directly onto a flat metal surface of at least 160 cm, the duty cycle can be extended up to 1.3 x nominal rating %ED Kraft-Weg-Diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 3 1 0, 0, 0,3 0, 0,1 0 0, 1 1, S [mm] 7 1 40 0 Force vs. Stroke diagramm F = f (s) Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 7 Main catalogue
HR 1 Stoßende Ausführung HR 1 Thrust type 3 9, Ø4, 0,4 ±0, 1 7,6 ±0,1, 14 M 3 6 1,3 7,4 1 Ø1, Ø3 0,63 Ø1, 19,0 ±0,1, Magnet Hauptkatalog 79 Main catalogue
Umkehr-Hubmagnet UH Stoßende und ziehende Ausführung Two-Directional UH Thrust and pull type Bestellformel UH L 4 V DC 0 % ED Order specifications Hubmagnet Bauart UH Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Lötpins F L Coil terminals Flying leads ( cm standard length) Soldering pins Nennspannung (Standardspannung) 1) 4 Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) 0 % ED Perm. duty cycle under air cooled conditions (LK) 1) Die Magnete sind auf Anfrage bis V DC lieferbar 1) Other voltages are available on request up to V DC Gewicht: Magnet: ca. 13 g Anker: ca. g Spannung: 4 V DC Litze: cm Isolierstoffklasse: E (T grenz = 1 C) Isolationsgruppe nach: VDE 01 C 0 Prüfspannung: 0 V (eff) UH-L 4 VDC 0%ED Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 13 g appr. g 4 V DC cm E (max. permissible temperature = 1 C) Insulation group according to: VDE 01 C 0 Test voltage: 0 V (eff) Zul. rel. Einschaltdauer (ED) ) % 0 0 1 % Perm. duty cycle (ED) ) Nennaufnahme P W,3 16 46 11 W Nominal coil power P ) Bei Montage auf eine Kühlfläche von mindestens 160 cm ist die 1,3fache ED zulässig ) If solenoid is mounted directly onto a flat metal surface of at least 160 cm, the duty cycle can be extended up to 1.3 x nominal rating 0 %ED 0 0 Kraft-Weg-Diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 3 1 0 1 3 4 S [mm] 1 0 0 Force vs. Stroke diagramm F = f (s) Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 0 Main catalogue
Umkehr-Hubmagnet UH Stoßende und ziehende Ausführung Two-Directional UH Thrust and pull type 3,, Ø M4 6 1, 1 Ø 1 3 7 14 1 1 43, Maße gelten, wenn System 1 bestromt < Dimensions given when system 1 currentcarrying < Magnet Hauptkatalog 1 Main catalogue
HL 1 Stoßende und ziehende Ausführung HL 1 Thrust and pull type Bestellformel HL 1 F 4 V DC 0 % ED Order specifications Hubmagnet Bauart HL 1 Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Steckkontakt (, x 0, DIN 4647; optional) Nennspannung (Standardspannung) 1) F A 4 Coil terminals Flying leads ( cm standard length) Steckkontakt (. x 0. DIN 4647; optional) Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) ) 1) Andere Spannung bis max. V DC auf Anfrage. ) Andere ED als 0 % ED auf Anfrage. 1) Other voltages up to max. V DC on request. ) Other ED than 0 % ED on request. Gewicht: Magnet: ca. 7 g Anker: ca. 1 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: Prüfspannung: VDE 01/4 KV/3, KV (eff) Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: Insulation group according to: Test voltage: appr. 7 g appr. 1 g 4 V DC cm B (max. permissible temperature = 1 C) VDE 01/4 KV/3. KV (eff) Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. In Sonderausführung mit eingebauter Rückholfeder lieferbar (auf Anfrage). Einbaulage (Ankergewicht) beachten. Service-free DU armature bearing for maximum durability. Return spring optional. Observe correct mounting (armature weight). Zul. rel. Einschaltdauer (ED) 3) % 0 40 6 % Perm. duty cycle (ED) 3) Nennaufnahme P W 13 4 77 W Nominal coil power P 3) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen) 3) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice) %ED Kraft-Weg-Diagramm F = f (s) F [N] 3 6 Force vs. Stroke diagramm F = f (s) 1 40 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0, 0,3 0, 0,1 0 1 3 4 6 S [mm] 0 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog Main catalogue
HL 1 Stoßende und ziehende Ausführung HL 1 Thrust and pull type Ø3 1 4 Ø14 Ø 3 9 36 37,, 1 4 in fully home position Magnet Hauptkatalog 3 Main catalogue
HL 31 Stoßende und ziehende Ausführung HL 31 Thrust and pull type Bestellformel HL 31 F 4 V DC 0 % ED Order specifications Hubmagnet Bauart HL 31 Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Steckkontakt (, x 0, DIN 4647; optional) Nennspannung (Standardspannung) 1) F A 4 Coil terminals Flying leads ( cm standard length) Steckkontakt (. x 0. DIN 4647; optional) Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) ) 1) Andere Spannung bis max. V DC auf Anfrage. ) Andere ED als 0 % ED auf Anfrage. 1) Other voltages up to max. V DC on request. ) Other ED than 0 % ED on request. Gewicht: Magnet: ca. 133 g Anker: ca. 3 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: Prüfspannung: VDE 01/4 KV/3, KV (eff) Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: Insulation group according to: Test voltage: appr. 133 g appr. 3 g 4 V DC cm B (max. permissible temperature = 1 C) VDE 01/4 KV/3. KV (eff) Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. In Sonderausführung mit eingebauter Rückholfeder lieferbar (auf Anfrage). Einbaulage (Ankergewicht) beachten. Service-free DU armature bearing for maximum durability. Return spring optional. Observe correct mounting (armature weight). Zul. rel. Einschaltdauer (ED) 3) % 0 40 6 % Perm. duty cycle (ED) 3) Nennaufnahme P W 6, 14 7 4 W Nominal coil power P 3) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen) 3) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice) %ED Kraft-Weg-Diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 7 1 0, 0, 0,1 0 4 6 1 S [mm] 6 40 0 Force vs. Stroke diagramm F = f (s) Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 4 Main catalogue
HL 31 Stoßende und ziehende Ausführung HL 31 Thrust and pull type Ø3 Ø17 Ø1 3 1 1 4 9 1 1 4, 1 43 4 7 in fully home position Magnet Hauptkatalog Main catalogue
HL 61 Stoßende und ziehende Ausführung HL 61 Thrust and pull type Bestellformel HL 61 F 4 V DC 0 % ED Order specifications Hubmagnet Bauart HL 61 Linear solenoid Design type Anschlußart Litze (Standardlänge cm) Steckkontakt (6,3 x 0, DIN 4647; optional) Nennspannung (Standardspannung) 1) F A 4 Coil terminals Flying leads ( cm standard length) Steckkontakt (6.3 x 0. DIN 4647; optional) Nominal voltage (standard voltage) 1) Zulässige relative Einschaltdauer bei Luftkühlung (LK) ) 0 % ED Perm. duty cycle under air cooled conditions (LK) ) 1) Andere Spannung bis max. V DC auf Anfrage. ) Andere ED als 0 % ED auf Anfrage. 1) Other voltages up to max. V DC on request. ) Other ED than 0 % ED on request. Gewicht: Magnet: ca. 390 g Anker: ca. 90 g Spannung: 4 V DC Litze: cm Isolierstoffklasse: B (T grenz = 1 C) Isolationsgruppe nach: VDE 01/4 KV/3 Prüfspannung:, KV (eff) Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. In Sonderausführung mit eingebauter Rückholfeder lieferbar (auf Anfrage). Einbaulage (Ankergewicht) beachten. Weight: Complete solenoid: Armature: Voltage: Flying leads: Insulation class: appr. 390 g appr. 90 g 4 V DC cm B (max. permissible temperature = 1 C) Insulation group according to: VDE 01/4 KV/3 Test voltage:. KV (eff) Service-free DU armature bearing for maximum durability. Return spring optional. Observe correct mounting (armature weight). Zul. rel. Einschaltdauer (ED) 3) % 0 40 6 % Perm. duty cycle (ED) 3) Nennaufnahme P W 1 31 0 96 140 W Nominal coil power P 3) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen) 3) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice) Kraft-Weg-Diagramm F = f (s) Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 0 %ED 0 F [N] 1 0, 0, 0,1 0 1 S [mm] 6 40 0 Force vs. Stroke diagramm F = f (s) Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position Magnet Hauptkatalog 6 Main catalogue
HL 61 Stoßende und ziehende Ausführung HL 61 Thrust and pull type Ø4 M4 Ø Ø1 6 4 M4 1 M4 16 0, 70 3 in fully home position Magnet Hauptkatalog 7 Main catalogue
Magnet Hauptkatalog Main catalogue