BN Puffernetzwerk BN 1701 Buffer network BN 1701

Ähnliche Dokumente
Betriebsarten-Umschalter Common mode / Differential mode switch

NPLC NPLC 8500 Netznachbildung NPLC 8500 Line Impedance Stabilization Network

ISN Impedanz Stabilisierungs Netzwerk für PLC Impedance Stabilization Network for PLC

NNBM 8126-A 890. Bordnetznachbildung für Flugzeuge NNBM 8126-A 890 Single path airborne equipment LISN NNBM 8126-A 890

NNBL 8229-HV MIL-Netznachbildung Line Impedance Stabilization Network acc. to MIL-STD-461E. Abb. 1/Fig.1: NNBL 8229-HV front

Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

SY 9223-PLC IN 9223-PLC

Aktiver Tastkopf 0,1-100 MHz Active Voltage Probe MHz

VHBA :1 100 W-Balun mit Bikonus-Elementen BBA 9106 VHBA :1 100 W-Balun with Biconical Elements BBA 9106

HFRA Passive Magnetische Sende-Rahmenantenne Passive Magnetic TX Loop Antenna

Kompensationsnetzwerk NFCN Compensation Network NFCN

Newest Generation of the BS2 Corrosion/Warning and Measurement System

a) Name and draw three typical input signals used in control technique.

Breitband Hochgewinn Horn Antenne BBHA 9120 J Broadband High Gain Horn Antenna BBHA 9120 J

Quadratische Induktionsspule Square Induction Coil

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Electrical testing of Bosch common rail solenoid valve (MV) injectors

Electrical testing of Bosch common rail piezo injectors

Kalibrier-Senderahmen HFRA 5157 Transmit Loop Antenna for Calibrations HFRA 5157

Netznachbildung NNLK 8121 LISN NNLK Abb. 1 NNLK 8121 NNLK 8121

Fundamentals of Electrical Engineering 1 Grundlagen der Elektrotechnik 1

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

Dual polarisierte Breitband-Hornantenne Dual polarized broadband horn antenna

Tempest Netznachbildung TEMP 8400 Tempest AMN (LISN) TEMP Abb. 1. TEMP 8400 Fig. 1. TEMP 8400 LISN

SPINNER MOBILE COMMUNICATION

Certificate of conformity Generating unit, NS-protection

Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

UHF-SHF Breitband Log.-Per. Antenne UHF-SHF Broadband Log.-Per. Antenna

Übersicht MagTest System Kombinationen für Immunitätsprüfungen Overview MagTest System combinations for immunity testing

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

Mock Exam Behavioral Finance

Stromzwischenkreisumrichter Current Source Inverter (CSI)

2 Pfad V-Netznachbildung NSLK path V-LISN NSLK Abb. 1 NSLK 8117 Netznachbildung Fig.1 NSLK 8117 Artificial Mains Network (AMN)

C 146 EMV Gehäuse/EMC Housings

CDNE M3. Koppel-/ Entkoppelnetzwerk Coupling-/ Decoupling Network. Abb. 1 CDNE M3. Datasheet 1/8 Rev. A

Mikrowellen Bikonus-Breitband-Antenne Microwave Biconical Broadband Antenna. Specifications: Linear polarisierte Mikrowellen- Bikonus-Breitbandantenne

NNHV Hochvolt-Netznachbildung Single path high voltage AMN (LISN) Application: Anwendung:

Harry gefangen in der Zeit Begleitmaterialien

[[ [ [ [[ Natur, Technik, Systeme. Test, Dezember Erstes Semester WI10. PV Panel und Kondensator

PELTIER-HOCHLEISTUNGSMODULE

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

Shock pulse measurement principle

Typenreihe GH Lifting Solenoids

Stromzwischenkreisumrichter Current Source Inverter (CSI)

Stromzwischenkreisumrichter Current Source Inverter (CSI)

Tube Analyzer LogViewer 2.3

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

Radio Frequency Systems

Netznachbildung NNLK HV LISN NNLK HV. Abb. 1: NNLK HV Frontansicht Fig. 1: NNLK HV front view

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

FEM Isoparametric Concept

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

CAT Draht Impedanzstabilisierungsnetzwerk CAT wire Impedance Stabilization Network CAT Abb. 1 NTFM Datasheet 1/8 Rev.

SCHWARZBECK MESS - ELEKTRONIK

18007: 2m Big Wheel Horizontal polarisierte Rundstrahlantenne

Overview thermostat/ temperature controller

Hochkonstante Keramik-HF-Spulen Highly Constant Ceramic RF Coils

CABLE TESTER. Manual DN-14003

UWC 8801 / 8802 / 8803

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS

DC-Netznachbildung DC AMN (LISN)

FEM Isoparametric Concept

DC-Netznachbildung PVDC 8301 DC AMN (LISN) PVDC 8301

SPINNER MOBILE COMMUNICATION

Technical Terms Technische Daten: Operating voltage Betriebsspannungsbereich Rated Voltage Nennspannung

Parameter-Updatesoftware PF-12 Plus

Snap-in Outline Drawings / Snap-in Bauformen

Calibration Services Application Note AN001

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

Spezifikation für Freigabe / specification for release

Asynchronous Generators

Ein Stern in dunkler Nacht Die schoensten Weihnachtsgeschichten. Click here if your download doesn"t start automatically

NNLK Netznachbildung NNLK 8130 LISN NNLK Abb. 1: NNLK 8130 Fig. 1: NNLK Abb. 2: NNLK 8130 Fig. 2: NNLK Datasheet 1/8 Rev.

HEAG 151, 152, 153, 154 Digital Converter

D12 Tel. +49 (0)7081 / Fax +49 (0)7081 / Quattro LNBs. Ausgänge bei Teilnehmern. Outlets to receivers

Pressglas-Korrespondenz

Kalibrierschein Calibration Certificate

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

1 Title Detail specification for high screened coaxial RF-cable with tin soaked braid. Generic specification: IEC , IEC

Digital-Analog-Konverter (DAC)

NNBM KFZ-Bordnetznachbildung NNBM 8124 Single path vehicle AMN (LISN) NNBM Abb. 1/Fig.1: NNBM 8124

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Supersedes: - Superseded by: - Caution: Hazardous high voltage Work on the high-voltage transformer may be carried out by instructed personnel only!

NSLK Netznachbildung NSLK 8128 LISN NSLK Abb. 1 NSLK 8128 mit Option RC NSLK 8128 with option RC. Datasheet 1/10 Rev. A 0651.

prorm Budget Planning promx GmbH Nordring Nuremberg

splicetec ag Boesch 37 CH-6331 Huenenberg Tel +41 (0) Fax +41 (0)

Betriebsanleitung. Finhol Natural Tube Series - Booster. Technische Daten

JX3-PS1. Installationsanleitung. Version Lieferumfang

High Side Laserdiodentreiber mit TEC Controller

Ein- und Ausgangsspannung V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN

Level 2 German, 2015

AMS 508 ECOswitch SAT range Frequency range [MHz] Gain [db] 2 ± 2,5

0805 (2012) drahtgewickelt (AgPd/Ni/Sn Metallisierung) 0805 (2012) wire-wound (AgPd/Ni/Sn Metallisation)

NSLK Pfad V-Netznachbildung NSLK path V-LISN NSLK Abb. 1 NSLK 8127 Netznachbildung Fig.1 NSLK 8127 Artificial Mains Network (AMN)

Sporadischer Neustart von WPC-Geräten FINALE LÖSUNG

Transmit Combiners. ANTENNENTECHNIK Bad Blankenburg AG

6 FME FME. 140 Telegärtner Web: Tel: +49-(0) / Fax: +49-(0) /

1. Hardware Configuration Hardware-Konfiguration Software-Konfiguration Software Configuration...4

Transkript:

Puffernetzwerk BN 1701 Buffer network BN 1701 Beschreibung: CISPR 17 beschreibt die Methoden zur Charakterisierung der Störunterdrückung von passiven Entstörfiltern. Im Wesentlichen kommen drei Messverfahren zur Anwendung: Einfügungsdämpfung Impedanzmessung S-Parameter Messung Description: CISPR 17 describes Methods of measurement of the suppression characteristics of passive EMC filtering devices. The following three methods are mainly applied: Insertion Loss Measurement Impedance Measurement S-Parameter Measurement Da Entstörfilter und diskrete Entstörmittel in der Regel keine koaxialen Anschlüsse haben, besteht ein Bedarf an geeignetem Messzubehör und reproduzierbaren sowie aussagekräftigen Messverfahren. In der internationalen Norm CISPR 17 sind daher Methoden und Hilfsmittel definiert, die es erlauben, verschiedene Since EMC Suppression Filters do not come with coaxial connections there is a need for suitable measurement equipment to obtain reliable measurements. The international standard CISPR 17 includes several methods and measuring equipment which is useful to compare EMI suppression parts among each other and Datasheet 1/9 Rev. A

Entstörmittel untereinander zu vergleichen und von vorneherein zielgerichtete und wirkungsvolle Entstörmaßnahmen zu treffen. Auch im Standard MIL-STD-220 sind Verfahren zur Charakterisierung von Entstörmitteln enthalten. allows an efficient selection of appropriate EMI suppressor devices. The MIL-STD- 220 also includes methods to measure the insertion loss of passive EMI filters. Speziell zur Messung an Filtern werden Koppelnetzwerke (sog. Puffernetzwerke) benötigt, durch die dem Prüfling (DuT) der im Betriebsfall auftretende Strom aufgeprägt werden kann. Allerdings darf das Puffernetzwerk die Messung nicht beeinflussen und es soll gleichzeitig die Messmittel vor Beschädigung durch den Prüfstrom schützen. In der Regel wird sowohl am Eingang als auch am Ausgang des Prüflings je ein derartiges Puffernetzwerk benötigt. Realisiert werden diese Netzwerke durch L/C Hochpässe. Für solch ein Puffernetzwerk haben sich auch die Begriffe Bias Tee und DC- Bias eingebürgert. In der CISPR 17, Anhang D wird das im Bild 1 gezeigte Prinzipschaltbild vorgeschlagen. C1 bildet den Trennkondensator zum Generator bzw. zum Pegelmesser. Seine Impedanz muss gerade bei tiefen Frequenzen im Verhältnis zum Systemwiderstand vernachlässigbar klein sein und er darf keine störenden Eigenresonanzen aufweisen. Über die Induktivität L1 wird der Strom von der Belastungsquelle zum Prüfling geleitet. Die Impedanz der Spule muss im Testfrequenzbereich groß genug sein, um die Messung nicht zu verfälschen. C2 bildet eine HF-Abblockung, um keine Signalverkopplung über die Belastungsquelle zu bekommen. Especially when measuring filters coupling networks (so called buffer networks) are required which are able to apply the current that occurs during regular operation to the device under test. Nevertheless the buffer network may not influence the measurement and it is supposed to protect the measuring equipment from getting damaged by the test current injected. Usually it is required to connect one buffer network each to the input and to the output of the device under test. The networks consist of L/C high pass filters. Sometimes these buffer networks are called BIAS Tee or DC BIAS as well. Within the standard CISPR 17 you can find the principle schematic in figure 1 in annex D. C1 decouples the DuT from the generator respectively from the level meter. It s impedance has to be small in proportion to the system impedance especially at low frequencies and it must not show disturbing self-resonances. The inductor L1 provides the current from the load source to the device under test The impedance of the coil has to be big enough within the frequency range of the test set-up to prevent the measurement result from being distorted. The capacitor C2 blocks RF from the load source. Datasheet 2/9 Rev. A

Bild 1: Prinzipschaltbild eines Puffernetzwerkes nach CISPR 17 Fig.1: Principle circuit diagram of a buffer network according to CISPR 17 Signalgenerator G Signal generator Koppelkondensator für HF-Signale C1 Coupling capacitor for RF-signals Entkoppelkondensator für Stromquelle C2 Decoupling capacitor for current source Entkopplungsinduktivität L1 Decoupling inductor EMV-Filter (Prüfling) FI EMC-filter (DuT) Belastungsstromquelle BS Load current source Koaxialer Anschluss für Signalgenerator/ Messempfänger B1 Coaxial connector for signal generator or EMI receiver Anschluss für den Prüfling B2 Terminal for the device under test Anschluss für die Belastungsstromquelle B3 Terminal for the load current source Verbindung zum Bezugspotential B4 Connection to reference ground Bild 2: Typischer Messaufbau Fig.2: typical test set-up Signalgenerator SG Signal generator Puffernetzwerk BN Buffer network EMV-Filter (Prüfling) FI EMC filter (device under test) Messempfänger R EMI receiver Belastungsquelle LS Load source Belastungsquellenanschlüsse E/F Connectors to load source Datasheet 3/9 Rev. A

Technische Daten: Specifications: Frequenzbereich: 100 khz 30 MHz Frequency Range: Rahmendurchmesser: 50 mm Loop Diameter: Anschluss Prüfling: 6 mm Flügelklemme mit Connector DuT: 4 mm Buchse/ 6 mm wing terminal including 4 mm banana jack Anschluss Einspeisung: 6 mm Flügelklemme mit Connector AE/BIAS: 4 mm Buchse/ 6 mm wing terminal including 4 mm banana jack Messgeräteanschluss: BNC 50 Ω Connector for measurement device: Zusatzdämpfung: Durchgangsmessung: Messung 0,1 Ω nach Masse: Messung 100 kω in Reihe: ±0.5 db ±1 db ±1 db Attenuation: Through: Measured with 0.1 Ω to ground: Measured with 100 kω in series: Zulässiger Strom: 32 A Max. current: Max. Anschlussspannung: 250 VAC / 400 VDC Max. terminal voltage: Gewicht: 650 g Weight: Abmessungen inkl. Buchsen: L x B x H: 170 mm x 120 mm x 49 mm Dimensions incl. connectors: length x width x height Normengrundlage: CISPR 17, Annex D2, D3 According to standard: Datasheet 4/9 Rev. A

Überprüfung der Einfügedämpfung: In der Norm CISPR 17 im Kapitel 5.4.3 werden drei Prüfungen jeweils mit offenen bzw. verbundenen Speiseanschlüssen der Belastungsstromquelle vorgegeben. Die folgenden Prinzipschaltbilder verdeutlichen den Messaufbau für die drei Fälle. In der Tabelle 1 sind die in der CISPR 17 geforderten Bedingungen an den Messaufbau enthalten. Hinweise: 1. Die dort angegebenen Dämpfungswerte beziehen sich auf die Leerlaufspannung des Signalgenerators. Üblicherweise beziehen sich Pegelangaben von Signalgeneratoren bzw. Netzwerkanalysatoren auf den Pegel bei Abschluss mit der Systemimpedanz von 50 Ω. Die letzte Spalte der Tabelle zeigt die Dämpfungsangabe unter Berücksichtigung der Signalquellenbelastung mit seiner Nennimpedanz. 2. Die Stromquelle muss schwebend, (also isoliert von den Gerätemassen) eingespeist werden. Die Überprüfung des Koppelnetzwerkes wird in der Norm CISPR 17 beschrieben. Dabei werden einmal zwei Koppelnetzwerke direkt miteinander verbunden und jeweils die Einfügedämpfung bei offenen Speiseklemmen und bei verbundenen Speisequellen gemessen. Bild 3 zeigt den Aufbau. Der nächste Test sieht vor, als Prüfling einen 0,1 Ω Widerstand nach Masse zu schalten und ebenfalls die Einfügedämpfung bei offenen Speiseklemmen und bei verbundenen Speisequellen zu messen. Im Bild 4 wird der Messaufbau gezeigt. Diese Messung ist praktisch jedoch nur bis etwa 500 khz sinnvoll durchführbar, da bei höheren Frequenzen schon ein beträchtlicher Einfluß von unvermeidbaren Serieninduktivitäten das Ergebnis sehr stark verfälscht! Verification of the insertion loss: Three measurements are specified in CISPR 17 chapter 5.4.3 in which the connectors of the load source are being left open or connected. The following principle schematics illustrate the measurement set-up for each of the three cases. Table 1 shows the circumstances for the test set-up required by CISPR 17. Note: 1. The attenuation values stated there refer to the open circuit voltage of the signal generator. Normally level specifications of signal generators or network analyzers refer to the level when terminated with the system impedance of 50 Ω. The last column of the table shows the attenuation taking account the load of the signal source with its nominal impedance. 2. The current source has to be injected floating (which means isolated from the system ground). The verification of the coupling network is described in CISPR 17. Therefore two couple networks have to get connected straight to each other and the insertion loss has to be measured once with AE connectors left open and once with an attached signal source. The test set-up is shown in fig.3. For the next test the DuT is a resistor of 0.1 Ω connected to ground. Again the insertion loss has to be measured once with AE connectors left open and once with an attached signal source. The test set-up is shown in fig.4. This measurement however is only practicable up to a frequency of 500 khz because unavoidable series inductances of straight wires strongly affect the measurements. Datasheet 5/9 Rev. A

Bei der letzten Messung, wie im Bild 5 zu sehen, wird in Serie zu den Koppelpunkten ein 100 kω Widerstand geschaltet und wiederum die Einfügedämpfung bei offenen Speiseklemmen und bei verbundenen Speisequellen gemessen. Bei dieser Messung ist einerseits ein Widerstand mit sehr kleinen parasitären Eigenschaften zu verwenden und andererseits zwischen den Koppelanschlüssen eine Abschirmung anzubringen. Hinweis für die praktische Messung: Ähnlich wie der eigentliche Prüfling verändert auch das Puffernetzwerk durch den Prüfstrom bzw. Betriebsstrom seine elektrischen Eigenschaften. Der Grund sind Sättigungseffekte des Ferritmaterials der Entkoppelinduktivität. Mit zunehmender Stromstärke wird die Induktivität kleiner. Dadurch verändert sich die Einfügedämpfung des Puffernetzwerkes. Um diesen Effekt zu eliminieren wird, vor jeder Messung mit einem anderen Prüfstrom, empfohlen eine Messung der Einfügedämpfung nach Bild 3 durchzuführen. Moderne Netzwerkanalysatoren bieten die Möglichkeit die Messkurve elektronisch zu speichern und damit eine Normalisierung durchzuführen. Ansonsten würde, besonders bei niedrigen Frequenzen, dem Prüfling eine zu hohe Filterwirkung zugeschrieben. For the last measurement a 100 kω resistor has to be connected in series to the couple joints. Once more the insertion loss has to be measured with the AE connectors left open and once again with the connected source. For this test set-up a resistor with very little parasitic capacitance has to be used and there has to be a shield between the couple joints. Hint for the practical measurement: Just the way the DuT changes its electrical properties when applying a test current the buffer network behaves similar. The reason therefore are saturation effects of the ferrite material of the coil. The higher the current is the lower the inductance gets. As a result the insertion loss of the buffer network changes. To get rid of this effect it is advised to test the insertion loss according to fig.3 before doing a measurement with another level of test current. Recent network analyzers do have the possibility to save the measurement graph and normalize the device to it. Otherwise the DuT would seem to have a better filter effect than it really has especially at lower frequencies. Datasheet 6/9 Rev. A

Bild 3: Überprüfung der Einfügedämpfung bei Durchgangsdämpfung (Durchführung) Fig. 3: Verification of the insertion loss (through) Bild 4: Eignungsnachweis des Messaufbaus mit 0,1 Ω nach Masse Fig. 4: Verification of the test set-up with a resistor of 0.1 Ω to ground Bild 5: Eignungsnachweis des Messaufbaus mit 100 kω in Serie Fig. 5: Verification of the test set-up with a resistor of 100 kω in series Bild 3 Fig. 3 Bild 4 Fig. 4 Bild 5 Fig. 5 Prüfung Test LS offen/ open LS Kurzschluss/ short LS offen/ open LS Kurzschluss/ short LS offen/ open LS Kurzschluss/ short R U2 U2/U0 Durchführung Through 0.5 x U0-6 db ±0.5 db U2/U0 korrigiert -0 db ±0.5 db R1 = 0.1 Ω 0.002 x U0-54 db ±1 db -48 db ±1 db R1 = 100 kω 0.0005 x U0-66 db ±1 db -60 db ±1 db Toleranz R1, R2: ±1% Datasheet 7/9 Rev. A

3 2 'THRUsh.asc' 'THRUop.asc' 'limthmx.asc' 'limthmn.asc' Insertion loss [db] 1 0-1 -2-3 0.1 1 10 Frequency [MHz] Bild 6: Einfügedämpfung beider Koppelnetzwerke Rücken an Rücken Fig.6: Insertion loss both coupling networks connected straight to each other 30-57 -58 'sh01.asc' 'op01.asc' 'lim01mx.asc' 'lim01mn.asc' Insertion loss [db] -59-60 -61-62 -63 0.1 1 10 Frequency [MHz] Bild 7: Einfügedämpfung mit 100 kω Serienwiderstand Fig.7: Insertion loss with 100 kω resistor in series 30 Datasheet 8/9 Rev. A

-45-46 'sh100.asc' 'op100.asc' 'lim100mx.asc' 'lim100mn.asc' Insertion loss [db] -47-48 -49-50 -51 0.1 1 Frequency [MHz] Bild 8: Einfügedämpfung mit 0,1 Ω Widerstand nach Masse Fig.8: Insertion loss with 0.1 Ω resistor connected to ground 5 SCHWARZBECK MESS ELEKTRONIK OHG An der Klinge 29 69250 Schönau, Germany Phone: +49 6228 1001 Fax.: +49 6228 1003 E-Mail: office@schwarzbeck.de www.schwarzbeck.de Datasheet 9/9 Rev. A