Structure-Borne Noise Sensor BKS 10

Ähnliche Dokumente
Körperschallsensor BKS 03

Vibration. Measurement. Years. Main Catalog Vibration Sensors Signal Conditioners Vibration Monitors Vibration Meters Vibration Calibrators

2Schwingungsaufnehmer. Vibration Transducers. IDS Innomic Gesellschaft für Computer- und Messtechnik mbh

Shock pulse measurement principle

Westenberg Wind Tunnels

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung

DC/DC-Wandler 37,5-75 W DC/DC Converter 37,5-75 W. Merkmale / Features

Betriebsarten-Umschalter Common mode / Differential mode switch

Ein- und Ausgangsspannung V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN

Aufbau des Steckverbinders: Construction of the connector:

TECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor

Signal Processing Präzisions-Sinusvervielfacher Wandlung von SinCos-Gebersignale in vervielfachte SinCos-Ausgangssignale

Werkzeugwagen VAS Tool trolley VAS

HF13-Programm HF13 Programme

Tachogeneratoren Vollwelle mit EURO-Flansch B10 Mit eigener Lagerung

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

ABB i-bus EIB. EIB Power Supply Units

Gestockte Log.-Per.-Breitband-Antenne Stacked Log.-Per.-Broadband Antenna

New ways of induction heating in the injection moulding process

Technische Daten / Technical data

Tachogeneratoren. Gehäuse ø95 mm, lagerlose Ausführung GTB 9. Merkmale. Kurze Reaktionszeit Leerlaufspannung mv pro U/min

GD/ SERVICE DOCUMENTATION. Tube 100

Signal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type

M12 Verteilerinsel / M12 Splitter box

Lufft UMB Sensor Overview

C-TEC Systemtechnik und Serviceleistung für die Werkstoffprüfung GmbH

HEAG 151, 152, 153, 154 Digital Converter

Winkel + Flansche 9Angles + Flanges

Technisches Datenblatt Technical Data Sheet. Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Familie 1 Channel Hall M18 Type

Attenuator and Distribution System Zehnder ComfoWell 520

Induktive Näherungsschalter

PACKTISCH PACKAGING TABLE

Technical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00)

LED Treiber: Anschlussschemata LED driver: connection diagrams

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

miditech 4merge 4-fach MIDI Merger mit :

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS

Heizleistung bei 20 C / Thermal output at 20 C. 2-polige Zugfederklemme 2 poles spring-cage terminal IP 20. II (*) Verfügbar ab Januar 2012

Aktivelektronik VP 150

E1 M1 P5 TK2 K2 20,6. hohe elektrische Nennleistung Schlüsselabzugstellung (Option) Wahl Aus/Ein. Umschalter/Wechsler. mit Federumkehr oder Umschalter

Sensoren / Sensors XA1000 / XP200 / XP400 XP100 / XP101.

RECKMANN GMBH MESS + REGELTECHNIK

Technical Specification. Technische Spezifikation

Quadt Kunststoffapparatebau GmbH

Manual Positioning Systems

Temperatursensor 1polig über Masse. Temperatur Sensor 1-pole common ground. Betriebssystem. switching on power supply

Externer Temperaturfühler External temperature sensor

Subminiatur Rundsteckverbinder Serie 711 Subminiature circular connectors series 711. Kurzinformation Brief information Ü TI

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

Hochkonstante Keramik-HF-Spulen Highly Constant Ceramic RF Coils

Kurzinformation Brief information. Subminiatur Rundsteckverbinder Serie 711 Subminiature circular connectors series 711 Ü TI

E/A-Bedieneinheit. I/O Control unit DE/GB 08/02

C 146 EMV Gehäuse/EMC Housings

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

DC/DC Converter 400 W

SIMID Size 1210 (EIA) or 3225 (IEC) Rated inductance 0,0082 to 100 µh Rated current 65 to 800 ma

Cable specifications (see page 21) Cable specifications (see page 21)

rear view server cabinet perforated steel door, divided

Distanzmontageteilen. Distance rolls

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät

Fließbett Fluidizing bed

DIGICONTROL-Gerätedatenblatt W-WLZ Anwendung. Schnittstellen 1xS0-Impulsausgang nach DIN , 1xM-Bus nach DIN , -3

Wartungsfreie Schleifringübertrager Maintenance Free Slip Ring Transmitters. A Division of The Morgan Crucible Company plc

Induktive Näherungsschalter inductive proximity switches

AC/DC-Schaltnetzteile 100 W AC/DC Switching Power Supplies 100 W. Merkmale / Features. Eingangsbereich V AC

FMC. 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany, Phone +49 (0) , info@rosenberger.de,

CL I IP20. 9MX056 MDU-PWR Starter Set/Extension Set. Mounting instructions. New Installation/Neuinstallation. 9MX056 MDU-PWR Starter Set

Mini OEM Sender / Mini OEM Transmitter

г.минск тел.8(017) DD 400 S 17 K6 B2 RMS, f = 50 Hz, t = 1 min. V ISOL 4 kv

K...<Bestell-Nr. / code>

D-Sub Dualport Steckverbinder D-Sub dualport connectors

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

Standardteile Schraubenkopf- dichtung Bonded Seals

- Characteristic sensitive Small temperature differences. - Low Sensitivity 42,8 µv/k for Cu-Constantan

Technische Daten /Techn. Terms Bedingungen/Conditions Wert/Value

Telemetrie-Messtechnik Schnorrenberg

CABLE TESTER. Manual DN-14003

TW-75-IP40Trackball. Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40. Description

Kuhnke Technical Data. Contact Details

direktgesteuert direct acting

Technisches Datenblatt Technical Data Sheet A4B. Signalwandler für 4 analoge Eingangssignale 4-20mA auf CAN

LED Treiber: Anschlussschemata LED driver: connection diagrams

LORENZ MESSTECHNIK GmbH

DOL 12. DOL 12 is a simple temperature sensor encapsulated by plastic material and suitable for usage in environments requiring a sturdy design.

FÜLLSTANDSMESSTECHNIK LEVEL MEASUREMENT PRODUKTÜBERSICHT PRODUCT OVERVIEW

P A max. 100bar A P max. 16bar

Radio Frequency Systems

Westfalia Bedienungsanleitung. Nr

Überspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden. Circuits using TVS Diodes

CSC 500 Sensor System for Ring Electrode and ISC CSC 500 Sensor System für Ring Elektrode und ISC

D-Sub Dualport Connectors D-Sub Dualport Steckverbinder

Dach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren

Pneumatic linear actuator - series MSR with cylinder Pneumatischer Linearantrieb Serie MSR mit Zylinder

Network premium POP UP Display

Sampling Rate / Sample rate. Modulation (gem. DVB-Standard) Modulation (DVB standard) 16 QAM 256 QAM QPSK, 16 QAM, 64 QAM

Hochstrom-Druckkontakte für Dauerströme bis 400 A. High Current Probes up to 400 amps cont. Ausgabe 7/2009 DE EN. Edition 7/2009 DE EN

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

Transkript:

Industrielle Meß- und Prüftechnik Structure-Borne Noise Sensor BKS BKS Sensor with adapter to BKS03 thread Mai 20 Neustadt 12, 37073 Göttingen, Telefon: +(49) 551/54833-0, Fax: +(49) 551/54833-43 email: info@discom.de, http://www.discom.de

Design The BKS implements the design of the BKS03 with a very light-weight sensor on top of an elastic element. As an enhancement, the BKS is much slimmer and attaches to surfaces that are close to ribs and other obstructing surfaces. Furthermore, the cable is protected as it is guided in an internal pipe. The sensor used is of ICP type and has a a sensitivity of mv/g (1 mv/nm/s 2 ) These sensors weigh about 2 g and respond to frequencies up to 12 khz. The sensor is mounted on a silicon element, the top of it's casing contacting the unit under test. A small steel plate is attached to the device and electrically isolated to prevent malfunction. Because of the small weight, the relatively large contact area, and the absorption of vibration by the elastic element, resonance remains at a minimum. For the two figures below the transfer function of the Discom sensor and the transfer function of reference sensor were subtracted. Both sensors measured the structure-borne noise within a gear box. For figure A the Discom sensor was applied to the reference sensor, thereby ensuring that both sensors measure the same signal. For figure B the Discom sensor was applied to the gear box approximately 2cm from the reference sensor. Figure A exhibits almost linear transfer, both sensors being fed the same signal. Figure B is necessarily less perfect, because the difference actually measured owes in part to the varying signal at the two points on the gear box. Nevertheless no typical resonance frequencies were measured. dbg TrnsFnc 0.0-5.0 -.0-15.0-20.0 Fig. A. Deviation of transfer function of Discom-sensor to transfer-function of reference sensor. Discom sensor applied directly to reference sensor. Function shows no resonance frequencies. TrnsFnc 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 k Hz dbg 0.0-5.0 -.0-15.0-20.0 Fig. B. Deviation of transfer function of Discom sensor to transfer function of reference sensor. Discom sensor applied to a point on the gear box a short distance from the reference sensor. Function shows no resonance frequencies. 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 k Hz

Mechanical Drawing BKS 51,45 49,95 48,55 44,80 75,95 Ø12,00 Ø15,00 Ø16,00 Ø18,00 R 17,00 90,00 Wrench size 7x2 mm Details of BKS, all dimensions in mm 35,00 50,00 5,50 17,00 M6 M27x1,5 Ø16,00 M4 Ø12,00 5,50 3,00 11,00 8,00 Senkung-Bohrung M4 DIN 974 Details of adapter BKS03-A for BKS, all dimensions in mm

Adapter and Cable Configurations BKS FE ART-02616,40 Adapter BKS / BKS03 thread ART- 02612 5,50 7,80 18,00 12,00 M6 M27x1,5 11,40 40,00 24,40 50,50 Cable axial with silicon pipe Charge cable silicon 1,5m ART- 02619 Silicon pipe to protect the cable do not use inside the BKS the cable must have 5mm space for moving Cable lateral Accelerometer KS91E1 ICP type mv/g ART- 02618 Cable axial 2,00 Cable lateral DIS C O M Tel. +49 551 548330 Fax. +49 551 5483343 gez.:j. Lorenz BKS adapter MATERIAL: aluminium / silicon Scale: 1:1 2009-11-24 ZEICHN.NR. 091124-01 BLATT 1 von 1

Technical Data BKS Sensor axial Sensor transversal KS91E1 ICP type accelerometer with mv/g, or 1 mv/nm/s2 KS91F2 ICP type accelerometer with 25 mv/g, or 2,5 mv/nm/s2 Upper frequency limit: approx. khz Can be connected to Rotas systems configured as: ICP Input Minimum resonance due to small weight of 1,7 g and resonance absorption by silicon element. Adapts to uneven surfaces. Preload advice. axial transversal 2,00mm 4,0 N 5,00mm,0 N

Components of BKS ICP Sensor MMF KS91E1 mv/g ART-02618 BKS FE Elastic element ART-02616 Charge cable 1,5m with protective hose ART-02619 Measuring direction Adapter UNF -32/BNC ART-00281 BNC- Adapter ART-043 Cable BNC RG58 ART-00265x..m Discom PC with ICP 24V ICP Sensor MMF KS91F2 25mV/g ART-02800 Measuring direction Supplies for all systems: BKS Adapter BKS / M27x1,5 ART-02612 Lock nut M27x1,5 DIN EN 24035 ART-02043 BKS Adapter M3 / M6x0,5 ART-02623 Adapter to keep on using KS91D, KS91E on BKS Spanner 8mm ART-02657 Spanner 7mm ART-02732 D ISCC OM Industrielle Meß- und Prüftechnik Entwurf: Tel=+49/551/548330 Fax=+49/551/5483343 37073 Göttingen Germany J. Lorenz BKS Components Rev.2 Project: All projects Drawing 130307-02 Datum: 2013-03-07 Blatt: 1 von 1

KS91E1 IEPE-Beschleunigungsaufnehmer mit ringförmiger, isolierter Tastfläche aus Edelstahl M6x0,5 Gewinde zur Befestigung des Tastkopfes Empfindlichkeit: mv/g Hoher Dynamikbereich Hohe Resonanzfrequenz IEPE accelerometer with ringshaped, insulated probe made of stainless steel M6x0,5 thread to coupling the probe Sensitivity: mv/g Wide dynamic range High resonant frequency B ua (T) mg 5 Noise 0 1-5 0,1-0,01-15 0,001-20 20 60 0 C 0,1 1 Hz 0 30 Bua(f) 20 0-1 0 00 000 0000 Hz Arbeitstemperaturbereich T min/t max -20 / 120 C Piezosystem Piezo design Scherprinzip Shear design Spannungsübertragungsfaktor Voltage sensitivity B ua ± mv/g Linearer Frequenzgang (am Messkopf) Linear frequency range (on the probe) ±3dB ± ±5 4... 18.000 8....000 12... 8.000 Resonanzfrequenz Resonant frequency f r > 42 (+25dB) khz Messbereich Range a+ / a- ± 700 g (pk) Bruchbeschleunigung Destruction limit a max 8000 g (pk) Querrichtungsfaktor Transverse sensitivity G 90max < 5 Keramikkapazität Ceramic Capacitance C i 200 pf Ausgang Output IEPE kompatibel IEPE compatible Konstantstromversorgung Constant current supply I CONST 2..20 ma Arbeitspunktspannung Output bias voltage U BIAS @4mA; @25 C @Tmin @Tmax..12 +5-15 Nichtlinearität Total harmonic distortions THD @a +/a - 2 Ausgangsimpedanz Output resistance r a @4mA < 50 Ω Untere Grenzfrequenz Low cut-off frequency f ug -3dB 4 Hz Störgrößen Environmental characteristics Eigenrauschen Residual noise a n_rms (0,5.. 20k)Hz < 30 mg Temperaturkoeffizient der Empfindlichkeit Temperature coefficient of sensitivity a n @1 Hz @ Hz @0 Hz TK(Bua) @T< 20 C @T> 20 C 00 0-0, -0,13 Hz V µg/ Hz Temperatursprungempfindlichkeit b at 0,15 ms -2 /K Temperature transient sensitivity Magnetfeldempfindlichkeit Magnetic field sensitivity b ab - ms -2 /T Mechanische Daten Mechanical data Abmessungen Dimensions / h 7,8 / 15,5 mm Koppelflansch für Sensoraufnahme coupling flange / h M6x0,5 / 2,2 mm Masse ohne Kabel Weight without cable m 1,85 g Gehäusematerial Case material Kabelanschluss Cable connection Kontaktbuchse Socket Aluminium / Edelstahl Stainless steel axial Subminiatur M3 Subminiature M3 Befestigung Mounting Messkopf probe adhesive / antasten touch Schutzgrad / Isolation Protection grade / Insulation - / Isolierter Messkopf insulated probe Anschlusszubehör Connection Accessories 054 / 013T / 017 / 016 + 051/x Befestigungszubehör Mounting Accessories 002 Passende Messgeräte Suitable Electronics M28 / M32 / M68 / M8 / M208 / M12 / VibroMetra Bestellinformation Ordering Information KS91E1: Aufnehmer mit B ua± Sensor with B ua± /K Metra Meß- und Frequenztechnik in Radebeul e.k. Meißner Str. 58 D-01445 Radebeul Tel. +49-(0)351-836 2191 P.O.Box 01 01 13 D-01435 Radebeul Fax: +49-(0)351-836 2940 Ausgabe / Edition: 05/11 Internet: www.mmf.de Email: Info@MMF.de

KS91F2 IEPE-Beschleunigungsaufnehmer mit ringförmiger, isolierter Tastfläche aus Edelstahl Messachse in Querrichtung M6x0,5 Gewinde zur Befestigung des Tastkopfes geringes Rauschen IEPE accelerometer with ring-shaped, insulated probe made of stainless steel Main sensitivity in transverse direction M6x0,5 thread to coupling the probe Wide dynamic range low noise level B ua (T) 2 0-2 -4-6 -40 0 40 80 120 C 0 µg Noise 1 0,1 1 0 Hz Bua(f) 30 20 0-1 0 00 000 0000 Hz Arbeitstemperaturbereich T min/t max -30 / 120 C Piezosystem Piezo design Scherprinzip Shear design Spannungsübertragungsfaktor Voltage sensitivity B ua 25 ± 20 mv/g Messachse Axis of main sensitivity Linearer Frequenzgang (am Messkopf) Linear frequency range (on the probe) 3dB 5 Querrichtung Transverse direction 0,6... 12.500 1,1... 8.000 1,5 6.800 Resonanzfrequenz Resonant frequency f r < 30 (+25dB) khz Messbereich Range a+ / a- ± 240 g (pk) Bruchbeschleunigung Destruction limit a max 8000 g (pk) Querrichtungsfaktor Transverse sensitivity G 90max < 5 Keramikkapazität Ceramic Capacitance C i 200 pf Ausgang Output IEPE kompatibel IEPE compatible Konstantstromversorgung Constant current supply I CONST 2..20 ma Arbeitspunktspannung Output bias voltage U BIAS @4mA; @25 C @Tmin- Tmax 12..14 V Nichtlinearität Total harmonic distortions THD @a +/a - 2 Ausgangsimpedanz Output resistance r a @4mA < 60 Untere Grenzfrequenz Low cut-off frequency f ug -3dB 0,6 Hz Störgrößen Environmental characteristics Eigenrauschen Residual noise a n_rms (0,5.. 20k)Hz < 1,5 mg Temperaturkoeffizient der Empfindlichkeit Temperature coefficient of sensitivity a n TK(Bua) @1 Hz @ Hz @0 Hz @T=(-30..20) C @T=(20..60) C @T=(60..120) C 60 15 4 0,01-0,03-0,05 Hz µg/ Hz Temperatursprungempfindlichkeit b at 0,15 ms -2 /K Temperature transient sensitivity Magnetfeldempfindlichkeit Magnetic field sensitivity b ab 2 ms -2 /T Mechanische Daten Mechanical data Abmessungen Dimensions / h 8,5 / 16 mm Koppelflansch für Sensoraufnahme coupling flange / h M6x0,5 / 2,2 mm Masse ohne Kabel Weight without cable m 2,6 g Gehäusematerial Case material Kabelanschluss Cable connection Aluminium / Edelstahl Stainless steel axial zum Tastkopf axial to probe Kontaktbuchse Socket Subminiatur M3 Subminiature M3 Befestigung Mounting adhesive / antasten touch Schutzgrad / Isolation Protection grade / Insulation Bestellinformation Ordering Information - / Isolierter Messkopf insulated probe KS91F2: Aufnehmer mit B ua±20 Sensor with B ua±20 /K Metra Meß- und Frequenztechnik in Radebeul e.k. Ausgabe / Edition: 09/12 Meißner Str. 58 D-01445 Radebeul Tel. +49-(0)351-836 2191 P.O.Box 01 01 13 D-01435 Radebeul Fax: +49-(0)351-836 2940 Internet: www.mmf.de Email: Info@MMF.de