Sartorius Com2TCP IP Software Programm

Größe: px
Ab Seite anzeigen:

Download "Sartorius Com2TCP IP Software Programm"

Transkript

1 Installation Guide Installationsanleitung Sartorius Com2TCP IP Software Programm Ethernet TCP/IP Ethernet TCP/IP

2 Contents English page 2 Deutsch pagina 36 2 Contents 3 Intended Use 4 Installation 13 Configuration The following symbols are used in these instructions: indicates required steps $ indicates steps required only under certain conditions > describes what happens after you have performed a particular step indicates an item in a list! indicates a hazard 2

3 Intended Use Com2TCP IP is a program for collecting and storing data received over a serial or Ethernet interface from measuring and testing instruments that are connected in a network. These instructions describe the procedures for installing and deinstalling the software under Windows XP. The procedure for installation under Windows NT4 and Windows 2000 is similar to that described here for Windows XP. Equipment Supplied CD (contains full version of Com2TCP IP) Dongle (hardlock) Installation instructions (this manual) System Requirements CPU: 400 MHz or faster Memory: At least 256 MB of RAM Monitor: 800 X 600 pixels Operating system: Windows NT4, SP 6a or Windows 2000, SP 4 or Windows XP, SP 1 Features Devices are connected over a COM server that converts the RS-232, RS-485 or RS-422 interfaces on the measuring instruments to Ethernet TCP IP. The software installed on the host computer reads user-specified items in the data records sent by the measuring instruments, and stores this data in a central database (SPCfWin or xbase). Measured values can be collected automatically or at timed intervals. Legal Notices Copyright This documentation may not be duplicated or transmitted for any purpose whatsoever, whether in whole or in part, without the express written permission of Sartorius AG. All rights defined under copyright law are reserved by Sartorius AG. This documentation is intended for use by the purchaser only. Transfer to third parties, whether free of charge or in return for payment, is not permitted. The software on the enclosed CD-ROM is the property of Sartorius AG. The software may not be copied, modified, reverse engineered, or modified through assimilation. The purchaser may operate the software for his/her own purposes only, and may not permit use of the software by third parties, neither free of charge nor in return for payment. If you have any problems with the enclosed software, please inform the software vendor. Sartorius AG reserves the right to supply updated software with this product. No liability is accepted for software installed prior to the purchase of this product. Users are liable for misuse. Note Windows NT 4, Windows 2000 and Windows XP are registered trademarks of Microsoft Inc. 3

4 Installation Installing the Dongle Driver Ethernet TCP/IP Ethernet TCP/IP Insert the CD-ROM in the CD drive. > Select the drive in the Windows Explorer. Double-click to open the dongle directory Open the Disk1 directory. Run Setup.exe. > Installation is executed. 4

5 Click the [Next >] button. > The license agreement is displayed. > The software on the enclosed CD-ROM is the property of Sartorius AG. Click the [Next >] button. 5

6 Enter or confirm the path for installation of the driver on the computer. Note: The illustration here shows computer s the C: drive. Click the [Next >] button. Select Network, Stand alone or None to indicate the type of dongle connected. > Network: Drivers are installed to perform the following tasks: Find and display any network dongles installed for other computers or programs Manage existing network dongles > Stand-alone: Drivers are installed to perform the following task: Find and display the stand-alone dongle connected to the computer Note: The dongle supplied with this program is a stand-alone dongle. In general, this is the setting to be selected here. > None: There is no dongle connected to this computer. Select an option and click the [Next >] button. 6

7 > The required drivers are installed. > The installation path is displayed. Once the installation is successfully concluded, click the [Finish] button. 7

8 Installing the Program Insert the CD-ROM in the CD drive. > Select the drive in the Windows Explorer. Click on the setup.exe file to run it. > The Com2TCP IP installation program opens. Click the [Next >] button. > The License Agreement window opens. 8

9 Accept the License Agreement. Click the [Next >] button. Enter your user name. Click the [Next >] button. > The installation path is displayed Click the [Next >] button. 9

10 Select the desired language. Click the [Next >] button. Before you run the Com2TCP IP program, connect the dongle, included with the software, to your computer. Disconnect the printer connector, if necessary, and use the LPT1 port. Connect the printer cable to the back of the dongle. 10

11 Click the [Install] button. > The installation program is executed. > The program is installed. > This window indicates that the installation was successful. Once the installation is successfully concluded, click the [Finish] button. 11

12 Click the Windows [Start] button and select [Programs], [Sartorius AG], [Com2TCPIP] to run the program. > If desired, you can install a shortcut on your Windows desktop by using the mouse to drag and drop this icon. > During start-up, the program checks whether the dongle is installed. > If the dongle is not found, the error message shown here opens. Note: Contact Sartorius AG for information on licenses for connecting devices. 12

13 Configuration Note: The Com2TCP IP program from Sartorius includes an on-line Help program. Pressing F1 opens a Help text about whichever program element is active when the F1 key is pressed. Explanatory texts are available for each of the program dialogs. ComServer Program configuration is described below with a number of examples, following some prefatory remarks on basic aspects of the program: The computer acts as a server and accumulates the data transmitted from the connected devices (network clients). The data is prepared and specified portions of each data record are read and stored in tables created by the user. Data can also be transmitted to an SPCfWin system. All client devices are connected to a ComServer (e.g., 62PC-Y020). The ComServer converts data received over the serial interface to the Ethernet TCP/IP standard. The ComServer must be connected to the RS-232 interface on each device from which data is to be collected. For details on installing the ComServer (e.g., 62PC-Y020), refer to the instructions supplied with the server. Refer to the operating instructions for each client device (e.g., scale) to set the required baud rate in each device. The baud rate setting is configured either in the operating menu or in the data interface of the device. In Sartorius products, configure the following settings: 1200 baud, odd parity, 7 data bits and one stop bit. The computer receives raw data from the clients. The program can request data from each client at regular intervals ranging from 1 second to 24 hours. Some client devices; (e.g., checkweighers) can send data automatically, at timer-controlled intervals. The unique features of this program include the flexible detection and distinction of different data, and the ability to read specified portions of extensive data strings. The examples given in the following assume the reader has basic knowledge of network and database technologies. Connecting Clients and Setting Up Tables for Data Collection Example 1 Double-click on the Com2TCPIP shortcut > The Com2TCP IP program runs. > The user interface opens. Open the Settings menu. 13

14 Select Options. > The Common program settings dialog opens. General settings are configured here. Click the [...] key next to the xbase/dbf tables field. > The path for the data to be stored is displayed. You can change the path, if desired. To do this, create a directory and specify it here or select an existing directory. Click OK to confirm Repeat this procedure for the next setting: Click the [...] key next to the Archived data records field. > Enter a path for storing data. Click the [...] key next to the Records not decoded/not stored field. > Enter a path for storing data. > This concludes configuration of paths for storing data. 14

15 Select IP configuration. > The IP Configuration dialog opens. This is where the IP addresses, ports and network timeout are defined for communication with clients. In the IP filter section, select the Allow connect from every station option. When this setting is active, the program detects the connected clients and adds new clients automatically. Note: The port number entered under Port no. (receiving) must match the client s setting. The Timeout setting defines the maximum time to elapse between data packets received, after which the program assumes the client has stopped transmission. This dialog also lets you assign designations (for example, machine numbers) to specific IP addresses. You can also set up a TCP/IP echo client. Designations can be edited directly in this list. Click [OK] to confirm. Open the Base data menu. Select xbase files. The program can read structures in existing DBF files, and lets you edit or delete stored structures. The field list is displayed as a table. The user can define the database characteristics: Field number Field name (10 characters max.) Field type (numeric = numbers only; character = numbers or letters; memo = text, logic = yes/no; 1/0) Field length Number of decimal places Click Add or Delete to add or delete data. All data required by the operator must be specified in the database structure. Data is filtered from the incoming packets and entered in the fields specified here. 15

16 The individual field names, types, lengths and decimal places for measured data sent by the scales are configured here. Open the Structure menu and select Save to save the table. Enter a name for the table definition; in this example, WEIGHTS Click [OK] to confirm. 16

17 Open the File menu and select Show communication. > The Overview of communication dialog opens. You can view values sent by clients (scales) here. > When you run this dialog, the Current page is open, showing the values currently being sent. In this example, UNKNOWN is shown because no IP address has been allocated. Click on the Errors tab. This page shows that no IP address has been assigned yet. > Click the Show button. This shows which value was sent. Click Edit. 17

18 This opens the Layout definition window. Click Length under Recognition based on... and then click the double arrow [<<] next to the No. of chars. field. The number of characters is calculated and the result entered automatically (in this example, 10). Save the defined layout as follows: Open the Layout menu, select Save layout as..., enter a layout name (in this example: WEIGHTS ) Click [OK] to confirm. Close the dialogs. 18

19 Open the Base data menu. Select Manage layouts. Select Load layout. Select WEIGHTS, the layout that contains your table. Click [OK] to confirm. > The measured value received is displayed. WEIGHTS is shown as the layout name. 19

20 Open the Manage characteristics menu and select Add characteristic, xbase, and the file name: WEIGHTS Click OK to confirm. The WEIGHTS entry is displayed. Click the [+] to expand the node. The characteristics you have created in this database are displayed. 20

21 Select Address. Click the [...] button next to Constant value. > The Available internal data window opens, listing the parameters available. > Select IP address and click [OK] to confirm. Select Time. > The Address parameter is assigned. The exclamation point next to Address changes into a green dot. Click the [...] button next to Constant value. > The Available internal data window opens, listing the parameters available. > Select Time and click [OK] to confirm. Select WEIGHTS > The Time parameter is assigned. The exclamation point next to Time changes into a green dot. Select the displayed measured value (6 characters). Activate the Decode contents option. Click the [<<] button next to Length. The program automatically detects the length of the selected string. > Alternatively, you can enter position and length manually. Click Save definition; the specified value is saved. > If you click on Time or Save definition now, all items are displayed with a green dot. Save your definitions by selecting Save characteristic as... and entering a name, such as M_Measval1. 21

22 Open the Base data menu. Select Layout assignment. > The layout created must be assigned to the corresponding client. Select the client IP address and click the [New layout] button. Select the layout and click OK. Double-click on the client. > The assigned layouts are displayed. Double-click on the assigned layout. > The assigned characteristics are displayed. Double-click on the assigned characteristic. > The assigned characteristics are activated or deactivated. 22

23 Connecting a client machine and setting up a table for the data record Example 2 The example refers to a machine connected over a network to a server. The machine from which the Com2TCP IP program is collecting data transmits a typical data record. The data record, or packet, received must be decoded and certain data from the packet must be assigned in a table. The basic steps of this procedure are detailed in Example 1 above, and thus only outlined here. This example illustrates how to add and save typical user data in a table which you have created. Analysis and decoding of the data collected in a table The following data is to be monitored by the program and collected in a table: Date (...of the data record) Time (...at which the data record was sent) Prod. (product made/processed by this machine) Mach. (...which processed the above product) Mean (mean weight value for the sample) s (standard deviation of the sample) Min. (the lowest weight value in the sample) Max. (the highest weight value in the sample) Oper. (the person responsible for operation of the machine) Note: The abbreviations shown on the printed data record are explained in detail in the interface description or the instruction manual supplied with the particular machine. Data record configurations may differ; the illustration shows an example of one possible record. 23

24 Open the Base data menu. Select xbase files. The program can read structures in existing DBF files, and lets you edit or delete stored structures. The field list is displayed as a table. The user can define the database characteristics: Field number Field name Field type (numeric = numbers only; characters = numbers or letters; memo = texts, logic = yes/no or 1/0) Field length (max. 8 characters permitted) Number of decimal places Click Add or Delete to add or delete data. All data required by the operator must be specified in the database structure. Data is filtered from the incoming packets and entered in the specified fields. Open the Structure menu and select Save to save the list. 24

25 In this example, the table is saved under the name PRO_4712. Click [OK] to confirm. Open the File menu and select Show communication. > The Overview of communication dialog opens. You can allocate values sent by clients (scales) here. Click the Errors tab. This page shows that no IP address has been assigned to the data record yet. > Click the Show button. This shows which value was sent. Click Edit. 25

26 This opens the Layout definition window. Under Recognition based on..., click Keywords. > Enter or select the keywords in the data record. In this example: Prod. Contr. Mach. From this point on, the program searches for the specified keywords in every data record received from the connected client. If the keywords are found, the corresponding data is automatically stored in the layout created for this purpose. Click Add to store a keywords. Save the defined layout as follows: Open the Layout menu, select Save layout as... and enter a layout name (in this example: AWC ). Click [OK] to confirm. The AWC entry is displayed. Click [OK] to confirm. Open the Base data menu. Select Manage layouts. Select Load layout. Select AWC, the layout that contains your table. Click [OK] to confirm. 26

27 Open the Manage characteristics menu and select Add characteristic, xbase, and the file name: AWC. Click the [+] to expand the node. The characteristics you have created in this database PRO_4712 are displayed. > The data record sent by the client is displayed. Click on the term Operator next to the exclamation point. Activate the [Decode contents] option under Save definition. > A checkmark appears in the box. Select the Oper. data item; in this example, 1. Select [Line] in the Save definition section. Click the [<<] button next to the [Line] field. The line is automatically calculated by the program. Click the [<<] button next to the [Length] field. The values are automatically calculated by the program. 27

28 Select the term Date next to the exclamation point. > The dot that precedes the term Operator is green, indicating that the program has assigned the calculated values. Note: When editing the data record, make sure you mark precisely that element you wish to process; e.g., for Oper., the 1. If you have max. 20 operators, mark the space preceding the 1 as well. Activate the [Decode contents] option under Save definition. > A checkmark appears in the box. Mark the date (in this example, April ) in the data record. Select [Line] in the Save definition section. Click the [<<] button next to the [Line] field. The line is automatically calculated by the program. Click the [<<] button next to the [Length] field. The values are automatically calculated by the program. Select the term Machine next to the exclamation point. > The dot that precedes the term Date is green, indicating that the program has assigned the calculated values. Process all entries marked by exclamation points in the same manner. > Once all marked items have been processed, all of the dots are green. Note: After editing the last item, click on any other item or on Save definition to make the last marker in the list green. 28

29 Store the selected characteristics. Save your definitions by selecting Save characteristic as... and entering a name, such as M_4712. Click [OK] to confirm your changes. Open the Base data menu. Select Layout assignment. Assign the term AWC to the client. Double-click on the desired client. > The layouts are displayed. Double-click on the layout. > The assigned characteristics are activated or deactivated; in this example, M_4712. Click [OK] to confirm. 29

30 Connecting a client machine and setting up a table for the data record Example 3 The example refers to a machine connected over a network to a server. The machine from which the Com2TCP IP program is collecting data transmits a typical metal detection data record. The data record, or packet, received must be decoded and certain data from the packet must be assigned in a table. The basic steps of this procedure are detailed in Example 1 above, and thus only outlined here. The example illustrates how to add and save typical user data in a table which you have created. Analysis and decoding of the data collected in a table The following data is to be monitored by the program and collected in a table: Date (...of the data record) Time (...at which the data record was sent) Batch (the batch that was produced) Product (product made/processed by this machine) Metal detection (field by which the data record is recognized) Note: The abbreviations shown on the printed data record are explained in detail in the interface description or the instruction manual supplied with the particular machine. Open the File menu and select Show communication. > The Overview of communication dialog opens. You can allocate values sent by clients here. Click the Errors tab. This page shows that no IP address has been assigned yet. > Click the Show button. On this page you can view the values that have been sent (e.g., metal detection signals). 30

31 Click Edit. This opens the Layout definition window. Under Recognition based on..., click Keywords. Enter or select the keyword in the data record. In this example: Metal_signal_IO From this point on, the program searches for the specified keyword in every data record received from the connected client. If the keyword is found, the data record is searched for the specified values, which are automatically stored in the layout created for this purpose. Click Add to save the keyword value. Save the defined layout as follows: Open the Layout menu, select Save layout as..., enter a layout name (in this example: METAL_SIGNAL_IO Click [OK] to confirm. The METAL_SIGNAL_IO entry is displayed. Click [OK] to confirm. Open the Base data menu. Select xbase files. Define the individual field names, type, length and decimal places for the measured data for the records sent by the metal detector. 31

32 Open the Structure menu and select Save to save the table. File name in this example: Metalsig Click [OK] to confirm. Open the Base data menu. Select Manage layouts. Select Load layout. Select METAL_SIGNAL_10, the layout that contains your table. Click [OK] to confirm. 32

33 Open the Manage characteristics menu and select Add characteristic, xbase, and the file name: METALSIG. Click OK to confirm Click the [+] to expand the node. 33

34 Select the Batch term (the program window shows Charge for the term Batch ). Select the displayed batch (in this example, CH126 for Batch 126 ). Activate the Decode contents option. Click the [<<] button next to Length. The program automatically detects the length of the selected string. > Alternatively, you can enter position and length manually. > You are prompted to save the desired settings. Click Save definition; the specified value is saved. Select and edit the individual terms. Process all entries marked by exclamation points in the same manner. > Once all items have been edited, all of the dots are green. 34

35 To save the characteristic definition, open the Manage characteristics menu. Select Save characteristic as and enter a name; in this example, M_METAL Click [OK] to confirm. Open the Base data menu. Select Layout assignment. Assign the term METAL_SIG_IO to the client as follows: Double-click on the desired client. > The layouts are displayed. Double-click on the layout. > The assigned characteristics are activated or deactivated; in this example, M_METAL Click [OK] to confirm. 35

36 Inhalt 36 Inhalt 37 Verwendungszweck 38 Installation 47 Konfiguration Folgende Symbole werden in dieser Anleitung verwendet: steht vor Handlungsanweisungen $ steht vor Handlungsanweisungen, die nur unter bestimmten Voraussetzungen ausgeführt werden sollen > beschreibt das, was nach einer ausgeführten Handlung geschieht steht vor einem Aufzählungspunkt!Weist auf eine Gefahr hin! 36

37 Verwendungszweck Com2TCP IP ist ein Softwareprogramm zur Erfassung und Speicherung der Daten von Mess- und Prüfgeräten. Die Messund Prüfgeräte sind über ein Netzwerk verbunden und verfügen über eine Serielle- oder Ethernet Schnittstelle. Lieferumfang CD (Vollversion von Com2TCP IP) Dongle Installationsanleitung Diese Installationsanleitung beschreibt den Installations-, und Deinstallationsvorgang auf dem PC unter Windows XP. Die Installation unter Windows NT 4 und Windows 2000 ähnelt sehr dem Installationsablauf unter Windows XP. Mindestsystemvoraussetzungen: CPU mind. 400 MHz Arbeitsspeicher mind. 256 MB RAM Bildschirm 800 x 600 Bildpunkte Windows NT 4 SP6a Windows 2000 SP4 Windows XP SP1 Funktionsumfang Die Verbindung der Geräte erfolgt über einen ComServer, der die Schnittstellen der Mess- und Prüfgeräte (RS232C, RS485 oder RS422) auf Ethernet TCP IP wandelt. Die Software, die auf dem Zentralrechner installiert wird, liest das jeweilige Protokoll der vernetzten Mess- und Prüfgeräte an bestimmten Stellen aus. In einer Datenbank (SPCfWin oder xbase) werden die erfassten Daten abgelegt. Messwerte können sowohl automatisch, als auch zeitgesteuert erfasst werden. Rechtliche Hinweise Copyright Ohne ausdrückliche schriftliche Genehmigung der Sartorius AG darf kein Teil dieser Unterlagen für irgendwelche Zwecke vervielfältigt oder übertragen werden. Alle Rechte nach dem Gesetz über Urheberrecht bleiben der Sartorius AG vorbehalten. Der Erwerber darf die Unterlagen nur für eigene Zwecke nutzen und es Dritten weder unentgeltlich noch entgeltlich überlassen. Das auf dieser CD befindliche Programm ist Eigentum der Firma Sartorius AG. Die Software darf nicht vervielfältigt, verändert, zurückentwickelt oder durch Assimilation geändert werden. Der Erwerber darf die Software nur für eigene Zwecke nutzen und Dritten weder unentgeldlich noch entgeldlich überlassen. Sollte es Probleme mit der beiliegenden Software geben, bitte den Lieferanten informieren. Die Sartorius AG ist berechtigt aktualisierte Software einzusetzen. Eine Haftung für bereits installierte Software ist ausgeschlossen. Bei Missbrauch des Programms haftet der Anwender. Hinweis Windows NT 4, Windows 2000, Windows XP sind eingetragene Warenzeichen der Firma Microsoft Inc. 37

38 Installation Installation der Dongle-Treiber Ethernet TCP/IP Die CD in das CD-ROM- Laufwerk einlegen. > Über den Windows Explorer das Laufwerk anwählen. Mit einem Doppelklick den Ordner dongle öffnen Ordner Disk1 öffnen Ethernet TCP/IP Setup.exe ausführen. > Die Installation wird ausgeführt. 38

39 Button: [Next >] betätigen. > Der Lizenzvertrag wird angezeigt. > Das auf dieser CD befindliche Programm ist Eigentum der Firma Sartorius AG. Button: [Next >] betätigen. 39

40 Pfad zum Installations-Verzeichnis der Treiber auf dem PC eingeben oder bestätigen. Hinweis: Im Bild dargestellt ist der Laufwerksbuchstabe des PC, z.b.: der Buchstabe C. Button: [Next >] betätigen. Radio Button: Network, Stand alone oder None für die Benutzung des Dongle anwählen. > Network Es werden Treiber installiert. Die installierten Treiber: suchen bereits installierte Netzwerkdongle für andere PCs oder Programme und machen diese sichtbar verwalten bereits installierte Netzwerkdongle > Stand alone Es werden Treiber installiert. Die installierten Treiber: suchen den Stand-alone-Dongle an dem PC und machen diesen für die Benutzung sichtbar Hinweis: Da es sich bei dem im Lieferumfang mitgelieferten Dongle um einen Stand-alone-Dongle handelt, ist in der Regel diese Einstellung zu wählen. > None An diesem Rechner wird kein Dongle angeschlossen. Auswahl treffen, Button: [Next >] betätigen. 40

41 > Die verwendeten Treiber werden installiert. > Der Installationspfad wird angezeigt. Nach erfolgter Installation den Vorgang durch Betätigung des Buttons [Finish] beenden. 41

42 Installation des Programms Die CD in das CD-ROM-Laufwerk einlegen. > Über den Windows Explorer das Laufwerk anwählen. Datei setup.exe mit Mausklick starten. > Das Installations-Programm von Com2TCP IP wird geöffnet. Button: [Next >] betätigen. > Fenster Lizenzvertrag wird geöffnet. 42

43 Den Lizenzvertrag akzeptieren. Button: [Next >] betätigen. UserName eintragen. Button: [Next >] betätigen. > Der Installationspfad wird angezeigt Button: [Next >] betätigen. 43

44 Sprache anwählen. Button: [Next >] betätigen. Bevor der Start des Programms Com2TCP IP erfolgt, muss der im Lieferumfang mitgelieferte Dongle auf den Datenausgang des PC`s aufgesteckt werden. Den Druckeranschluss (LPT1) abziehen, Dongle aufstecken. Den Druckeranschlussstecker auf den Dongle aufstecken. 44

45 Button: [Install] betätigen. > Die Installation des Programms wird ausgeführt. > Das Programm wird installiert. > Die Installation war erfolgreich. Nach erfolgter Installation den Vorgang durch Betätigung des Buttons [Finish] beenden 45

46 Über die Task Leiste [Start], [Programme], [Sartorius AG] das Programm [Com2TCPIP] kann das Programm jetzt gestartet werden. > Das Icon kann auch fest auf der Oberfläche installiert werden. Dazu das Icon mit dem Mauspfeil auf die Bildfläche ziehen. > Während des Starts überprüft das Programm, ob der Dongle vorhanden ist. > Wurde der Dongle nicht richtig installiert, erfolgt eine Warnmeldung. Hinweis: Die Lizenzvergabe zum Anschluss von Geräten erfolgt durch die Sartorius AG. 46

47 Konfiguration Hinweis: Das Programm Sartorius Com2TCP/IP enthält eine Online-Hilfe. Die F1-Taste aktiviert die in dem Kontext erforderliche Hilfe. Die Hilfe wird an jeder beliebigen Position im Programm aktiviert. Entsprechende Texte und Erklärungen sind hinter den einzelnen Masken hinterlegt. ComServer Bevor an Hand von Beispielen die Konfiguration des Programms erfolgt, hier noch grundlegende Hinweise: Der PC fungiert als Server und sammelt die gesendeten Daten der vernetzten Geräte (Netzwerkclients). Die anfallenden Daten werden aufbereitet, die von dem Benutzer definierten Stellen des Protokolls ausgelesen und in vom Benutzer angelegten Tabellen gespeichert. Die Daten können auch an ein bestehendes SPCfWin-System übertragen werden. Jedes der anzuschließenden Geräte (Clients) wird über einen ComServer (z.b.: 62PC-Y020) angeschlossen. Der ComServer wandelt die serielle Schnittstelle in den Ethernet TCP/IP Standard. Der ComServer muss an die RS232 Datenschnittstelle des jeweilig zu erfassenden Gerätes angeschlossen sein. Die Installation des ComServer (z.b.: 62PC-Y020) erfolgt an Hand der beigelegten Installationsanleitung des ComServer Gerätes. Anhand der Betriebsanleitung des jeweilig angeschlossenen Gerätes (Client z.b.: Waage) muss die entsprechende Baudrate zur Übertragung der Daten eingestellt werden. Die jeweilige Einstellmöglichkeit erfolgt im Menü des Gerätes oder ist in der Schnittstellenbeschreibung des Gerätes beschrieben. Bei Sartorius Produkten ist eine Einstellung der Baudrate auf 1200 Baud, Odd Parity zu wählen, sowie 7 Datenbits und ein Stopbit. Die von dem PC empfangenen Daten entsprechen der unveränderten Zeichenkette (Rohdaten des Clients). Daten können von dem Programm in Intervallen von 1 Sekunde bis zu 24 Stunden per Steuerzeichen vom Clinet angefordert werden. Bei speziellen Clients (z.b.: Checkweigher) besteht die Möglichkeit anfallende Daten zeitgesteuert zu senden. Die besondere Eigenschaft des Programms ist die flexible Erhebung und Differenzierung unterschiedlicher Datenstrings, sowie das gezielte Auslesen umfassender Datenstrings. Die nachfolgenden Anwendungsbeispiele setzen grundlegende Netzwerk- und Datenbankkenntnisse des Anwenders voraus. Waage (Client) anschließen, Tabellen für die anfallenden Daten einrichten Beispiel: 1 Mit der Maus einen Doppelklick auf das Icon ausführen > Das Programm Com2TCP IP wird gestartet. > Die Benutzeroberfläche erscheint. Menü: Einstellungen anwählen. 47

Softwareupdate-Anleitung // AC Porty L Netzteileinschub

Softwareupdate-Anleitung // AC Porty L Netzteileinschub 1 Softwareupdate-Anleitung // AC Porty L Netzteileinschub Softwareupdate-Anleitung // AC Porty L Netzteileinschub HENSEL-VISIT GmbH & Co. KG Robert-Bunsen-Str. 3 D-97076 Würzburg-Lengfeld GERMANY Tel./Phone:

Mehr

Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen

Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen QuickStart Guide to read a transponder with a scemtec TT reader and software UniDemo Voraussetzung: - PC mit der

Mehr

Der Adapter Z250I / Z270I lässt sich auf folgenden Betriebssystemen installieren:

Der Adapter Z250I / Z270I lässt sich auf folgenden Betriebssystemen installieren: Installationshinweise Z250I / Z270I Adapter IR USB Installation hints Z250I / Z270I Adapter IR USB 06/07 (Laden Sie den Treiber vom WEB, entpacken Sie ihn in ein leeres Verzeichnis und geben Sie dieses

Mehr

Word-CRM-Upload-Button. User manual

Word-CRM-Upload-Button. User manual Word-CRM-Upload-Button User manual Word-CRM-Upload for MS CRM 2011 Content 1. Preface... 3 2. Installation... 4 2.1. Requirements... 4 2.1.1. Clients... 4 2.2. Installation guidelines... 5 2.2.1. Client...

Mehr

Installation und Start der Software AQ2sp Installation and Start of the software AQ2sp

Installation und Start der Software AQ2sp Installation and Start of the software AQ2sp Installation and Start of the software Abhängig von Ihrer WINDOWS-Version benötigen Sie Administrator-Rechte zur Installation dieser Software. Geeignet für folgende WINDOWS-Versionen: Windows 98 SE Windows

Mehr

p^db=`oj===pìééçêíáåñçêã~íáçå=

p^db=`oj===pìééçêíáåñçêã~íáçå= p^db=`oj===pìééçêíáåñçêã~íáçå= Error: "Could not connect to the SQL Server Instance" or "Failed to open a connection to the database." When you attempt to launch ACT! by Sage or ACT by Sage Premium for

Mehr

USB -> Seriell Adapterkabel Benutzerhandbuch

USB -> Seriell Adapterkabel Benutzerhandbuch USB -> Seriell Adapterkabel Benutzerhandbuch 1. Produkt Eigenschaften 1 2. System Vorraussetzungen 1 3. Treiber Installation (Alle Windows Systeme) 1 4. Den COM Port ändern 2 5. Einstellen eines RS232

Mehr

Parameter-Updatesoftware PF-12 Plus

Parameter-Updatesoftware PF-12 Plus Parameter-Updatesoftware PF-12 Plus Mai / May 2015 Inhalt 1. Durchführung des Parameter-Updates... 2 2. Kontakt... 6 Content 1. Performance of the parameter-update... 4 2. Contact... 6 1. Durchführung

Mehr

Nachdem Sie die Datei (z.b. t330usbflashupdate.exe) heruntergeladen haben, führen Sie bitte einen Doppelklick mit der linken Maustaste darauf aus:

Nachdem Sie die Datei (z.b. t330usbflashupdate.exe) heruntergeladen haben, führen Sie bitte einen Doppelklick mit der linken Maustaste darauf aus: Deutsch 1.0 Vorbereitung für das Firmwareupdate Vergewissern Sie sich, dass Sie den USB-Treiber für Ihr Gerät installiert haben. Diesen können Sie auf unserer Internetseite unter www.testo.de downloaden.

Mehr

SMARTtill Server mit Manager

SMARTtill Server mit Manager SMARTtill Server mit Manager Benutzerhandbuch 2014 Das Handbuch bezieht sich auf die Standardeinstellungen bei einer Pilotinstallation. Bei neuen Partnernprojekten sind Anpassungen zwingend notwendig und

Mehr

USB Treiber updaten unter Windows 7/Vista

USB Treiber updaten unter Windows 7/Vista USB Treiber updaten unter Windows 7/Vista Hinweis: Für den Downloader ist momentan keine 64 Bit Version erhältlich. Der Downloader ist nur kompatibel mit 32 Bit Versionen von Windows 7/Vista. Für den Einsatz

Mehr

Anleitung zur Schnellinstallation TFM-560X YO.13

Anleitung zur Schnellinstallation TFM-560X YO.13 Anleitung zur Schnellinstallation TFM-560X YO.13 Table of Contents Deutsch 1 1. Bevor Sie anfangen 1 2. Installation 2 Troubleshooting 6 Version 06.08.2011 1. Bevor Sie anfangen Packungsinhalt ŸTFM-560X

Mehr

How-To-Do. OPC-Server with MPI and ISO over TCP/IP Communication. Content. How-To-Do OPC-Server with MPI- und ISO over TCP/IP Communication

How-To-Do. OPC-Server with MPI and ISO over TCP/IP Communication. Content. How-To-Do OPC-Server with MPI- und ISO over TCP/IP Communication How-To-Do OPC-Server with MPI and ISO over TCP/IP Content OPC-Server with MPI and ISO over TCP/IP... 1 1 General... 2 1.1 Information... 2 1.2 Reference... 2 2 Procedure for the Setup of the OPC Server...

Mehr

v i r t u A L C O M P o r t s

v i r t u A L C O M P o r t s v i r t u A L C O M P o r t s (HO720 / HO730) Installieren und Einstellen Installation and Settings Deutsch / English Installieren und Einstellen des virtuellen COM Ports (HO720 / HO730) Einleitung Laden

Mehr

English. Deutsch. niwis consulting gmbh (https://www.niwis.com), manual NSEPEM Version 1.0

English. Deutsch. niwis consulting gmbh (https://www.niwis.com), manual NSEPEM Version 1.0 English Deutsch English After a configuration change in the windows registry, you have to restart the service. Requirements: Windows XP, Windows 7, SEP 12.1x With the default settings an event is triggered

Mehr

150Mbps Micro Wireless N USB Adapter

150Mbps Micro Wireless N USB Adapter 150Mbps Micro Wireless N USB Adapter TEW-648UBM ŸAnleitung zur Schnellinstallation (1) ŸTroubleshooting (6) 1.11 1. Bevor Sie anfangen Packungsinhalt ŸTEW-648UBM ŸCD-ROM (Dienstprogramm & Bedienungsanleitung)

Mehr

Galileo Desktop Benutzerhandbuch Version 1.02

Galileo Desktop Benutzerhandbuch Version 1.02 Galileo Desktop Benutzerhandbuch Version 1.02 Galileo Deutschland GmbH. All rights reserved. Dieses Dokument enthält Informationen, an denen Galileo International Rechte besitzt. Dieses Dokument darf nur

Mehr

BEDIENUNGSANLEITUNG. ba76147d01 04/2013. MultiLab User PC SOFTWARE ZUR BENUTZERVERWALTUNG

BEDIENUNGSANLEITUNG. ba76147d01 04/2013. MultiLab User PC SOFTWARE ZUR BENUTZERVERWALTUNG BEDIENUNGSANLEITUNG ba76147d01 04/2013 MultiLab User PC SOFTWARE ZUR BENUTZERVERWALTUNG MultiLab User 2 ba76147d01 04/2013 Inhaltsverzeichnis MultiLab User MultiLab User - Inhaltsverzeichnis 1 Überblick...................................

Mehr

Readme-USB DIGSI V 4.82

Readme-USB DIGSI V 4.82 DIGSI V 4.82 Sehr geehrter Kunde, der USB-Treiber für SIPROTEC-Geräte erlaubt Ihnen, mit den SIPROTEC Geräten 7SJ80/7SK80 über USB zu kommunizieren. Zur Installation oder Aktualisierung des USB-Treibers

Mehr

Dokumentation IBIS Monitor

Dokumentation IBIS Monitor Dokumentation IBIS Monitor Seite 1 von 16 11.01.06 Inhaltsverzeichnis 1. Allgemein 2. Installation und Programm starten 3. Programmkonfiguration 4. Aufzeichnung 4.1 Aufzeichnung mitschneiden 4.1.1 Inhalt

Mehr

KIP Druckerstatus Benutzerhandbuch KIP Druckerstatus Installations- und Benutzerhandbuch

KIP Druckerstatus Benutzerhandbuch KIP Druckerstatus Installations- und Benutzerhandbuch KIP Druckerstatus Installations- und Benutzerhandbuch - 1 - Inhalt 1 Einführung... 3 2 Installation und Einrichtung... 4 3 Funktionalität des KIP Druckerstatus... 6 4 Benutzung des KIP Druckerstatus...

Mehr

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens How-To-Do Hardware Configuration of the CC03 via SIMATIC Manager from Siemens Content Hardware Configuration of the CC03 via SIMATIC Manager from Siemens... 1 1 General... 2 1.1 Information... 2 1.2 Reference...

Mehr

Live Streaming => Netzwerk ( Streaming Server )

Live Streaming => Netzwerk ( Streaming Server ) Live Streaming => Netzwerk ( Streaming Server ) Verbinden Sie den HDR / IRD-HD Decoder mit dem Netzwerk. Stellen Sie sicher, dass der HDR / IRD-HD Decoder mit ihrem Computer kommuniziert. ( Bild 1 ) Wichtig:

Mehr

Kapitel 7 TCP/IP-Konfiguration zum Drucken (Windows NT 4.0)

Kapitel 7 TCP/IP-Konfiguration zum Drucken (Windows NT 4.0) Kapitel 7 TCP/IP-Konfiguration zum Drucken (Windows NT 4.0) Benutzer von Windows NT 4.0 können Ihre Druckaufträge direkt an netzwerkfähige Brother FAX/MFC unter Verwendung des TCP/IP -Protokolls senden.

Mehr

ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide

ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide ALL1681 Wireless 802.11g Powerline Router Quick Installation Guide 1 SET ALL1681 Upon you receive your wireless Router, please check that the following contents are packaged: - Powerline Wireless Router

Mehr

Outlook 2000 Thema - Archivierung

Outlook 2000 Thema - Archivierung interne Schulungsunterlagen Outlook 2000 Thema - Inhaltsverzeichnis 1. Allgemein... 3 2. Grundeinstellungen für die Auto in Outlook... 3 3. Auto für die Postfach-Ordner einstellen... 4 4. Manuelles Archivieren

Mehr

How-To-Do. Communication to Siemens OPC Server via Ethernet

How-To-Do. Communication to Siemens OPC Server via Ethernet How-To-Do Communication to Siemens OPC Server via Content 1 General... 2 1.1 Information... 2 1.2 Reference... 2 2 Configuration of the PC Station... 3 2.1 Create a new Project... 3 2.2 Insert the PC Station...

Mehr

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient Filing system designer FileDirector Version 2.5 Novelties FileDirector offers an easy way to design the filing system in WinClient. The filing system provides an Explorer-like structure in WinClient. The

Mehr

EMCO Installationsanleitung Installation instructions

EMCO Installationsanleitung Installation instructions EMCO Installationsanleitung Installation instructions Installationsanleitung Installation instructions Digitalanzeige digital display C40, FB450 L, FB600 L, EM 14D/17D/20D Ausgabe Edition A 2009-12 Deutsch...2

Mehr

Kurzanleitung zur Softwareverteilung von BitDefender Produkten...2

Kurzanleitung zur Softwareverteilung von BitDefender Produkten...2 Kurzanleitung zur Softwareverteilung von Kurzanleitung zur Softwareverteilung von BitDefender Produkten...2 I. BitDefender Management Agenten Verteilung...2 1.1. Allgemeine Bedingungen:... 2 1.2. Erste

Mehr

Installationsanleitung unter Windows

Installationsanleitung unter Windows Installationsanleitung unter Windows Verwenden Sie zur Installation ein Benutzerkonto mit Administratorberechtigung! 1. Download des aktuellen Backup-Client und des Sprachpakets: 1.1 Windows: ftp://ftp.software.ibm.com/storage/tivoli-storage-management/maintenance/client/v6r2/windows/

Mehr

iid software tools QuickStartGuide iid USB base driver installation

iid software tools QuickStartGuide iid USB base driver installation iid software tools QuickStartGuide iid software tools USB base driver installation microsensys Nov 2016 Introduction / Einleitung This document describes in short form installation of the microsensys USB

Mehr

Zentrale Installation

Zentrale Installation Einführung STEP 7 wird durch ein Setup-Programm installiert. Eingabeaufforderungen auf dem Bildschirm führen Sie Schritt für Schritt durch den gesamten Installationsvorgang. Mit der Record-Funktion steht

Mehr

CarMedia. Bedienungsanleitung Instruction manual. AC-Services Albert-Schweitzer-Str.4 68766 Hockenheim www.ac-services.eu info@ac-services.

CarMedia. Bedienungsanleitung Instruction manual. AC-Services Albert-Schweitzer-Str.4 68766 Hockenheim www.ac-services.eu info@ac-services. CarMedia Bedienungsanleitung Instruction manual AC-Services Albert-Schweitzer-Str.4 68766 Hockenheim www.ac-services.eu info@ac-services.eu DE Inhaltsverzeichnis 1. Allgemeine Hinweise... 3 2. CarMedia...

Mehr

Auswertung erstellen: Liste mit E-Mail-

Auswertung erstellen: Liste mit E-Mail- Anleitung Auswertung erstellen: Liste mit E-Mail-Adressen Auswertung erstellen: Liste mit E-Mail- Adressen Das Beispiel Sie möchten für den Versand eines Newletters per E-Mail eine Liste der in mention

Mehr

EchoLink und Windows XP SP2

EchoLink und Windows XP SP2 EchoLink und Windows XP SP2 Hintergrund Für Computer auf denen Windows XP läuft, bietet Microsoft seit kurzem einen Update, in der Form des Service Pack 2 oder auch SP2 genannt, an. SP2 hat einige neue

Mehr

Installationshinweise Z501J / Z501K Adapter IrDa USB Installation hints Z501J / Z501K Adapter IrDa USB

Installationshinweise Z501J / Z501K Adapter IrDa USB Installation hints Z501J / Z501K Adapter IrDa USB Installationshinweise Z501J / Z501K Adapter IrDa USB Installation hints Z501J / Z501K Adapter IrDa USB 1/3.04 (Diese Anleitung ist für die CD geschrieben. Wenn Sie den Treiber vom WEB laden, entpacken

Mehr

RS-232 SERIAL EXPRESS CARD 1-PORT. Expansion 111829

RS-232 SERIAL EXPRESS CARD 1-PORT. Expansion 111829 RS-232 SERIAL EXPRESS CARD 1-PORT Expansion 111829 1. Introduction equip RS-232 Serial Express Card works with various types of RS-232 serial devices including modems, switches, PDAs, label printers, bar

Mehr

MobiDM-App Handbuch für Windows Mobile

MobiDM-App Handbuch für Windows Mobile MobiDM-App Handbuch für Windows Mobile Dieses Handbuch beschreibt die Installation und Nutzung der MobiDM-App für Windows Mobile Version: x.x MobiDM-App Handbuch für Windows Mobile Seite 1 Inhalt 1. WILLKOMMEN

Mehr

Installationsleitfaden zum Fakturierungsprogramm

Installationsleitfaden zum Fakturierungsprogramm Installationsleitfaden zum Fakturierungsprogramm 22.05.07 002-Installationsleitfaden Systemvoraussetzungen Betriebssystem: Windows 2000/Service Pack SP4 Windows XP/Service Pack SP2 Windows 2003 Server

Mehr

SensoDirect 150. Lovibond Water Testing. Data Retrieve Software SW E2005. Tintometer Group. ph/orp DO CD/TDS. Bedienungsanleitung. Instruction Manual

SensoDirect 150. Lovibond Water Testing. Data Retrieve Software SW E2005. Tintometer Group. ph/orp DO CD/TDS. Bedienungsanleitung. Instruction Manual Lovibond Water Testing Tintometer Group SensoDirect 150 Data Retrieve Software SW E2005 DE GB Bedienungsanleitung Seite 2 5 Instruction Manual Page 5 7 CD/TDS ph/orp DO www.lovibond.com DE Inhaltsverzeichnis

Mehr

1 Installation QTrans V2.0 unter Windows NT4

1 Installation QTrans V2.0 unter Windows NT4 1 Installation QTrans V2.0 unter Windows NT4 1.1 Unterstützte Funktionen Unter NT4 wird nur der Betrieb von QTrans im Report-Client-Modus unterstützt, d. h. für die Anzeige von Schraubergebnissen und für

Mehr

HiOPC Hirschmann Netzmanagement. Anforderungsformular für eine Lizenz. Order form for a license

HiOPC Hirschmann Netzmanagement. Anforderungsformular für eine Lizenz. Order form for a license HiOPC Hirschmann Netzmanagement Anforderungsformular für eine Lizenz Order form for a license Anforderungsformular für eine Lizenz Vielen Dank für Ihr Interesse an HiOPC, dem SNMP/OPC Gateway von Hirschmann

Mehr

Bedienungsanleitung V1.0. PC-Programm / Konverter EP-Schachtmanagement. TECTUS Transponder Technology GmbH

Bedienungsanleitung V1.0. PC-Programm / Konverter EP-Schachtmanagement. TECTUS Transponder Technology GmbH Bedienungsanleitung V1.0 PC-Programm / Konverter EP-Schachtmanagement TECTUS Transponder Technology GmbH Eurotecring 39 D-47445 Moers ALLGEMEIN 4 Installation 4 PROGRAMMBESCHREIBUNG 5 1 TASKLEISTEN SYMBOL

Mehr

Xerox Device Agent, XDA-Lite. Kurzanleitung zur Installation

Xerox Device Agent, XDA-Lite. Kurzanleitung zur Installation Xerox Device Agent, XDA-Lite Kurzanleitung zur Installation Überblick über XDA-Lite XDA-Lite ist ein Softwareprogramm zur Erfassung von Gerätedaten. Sein Hauptzweck ist die automatische Übermittlung von

Mehr

Anleitung zur Installation von Windows XP Professional und dem Multilanguage Interface

Anleitung zur Installation von Windows XP Professional und dem Multilanguage Interface Anleitung zur Installation von Windows XP Professional und dem Multilanguage Interface Installation Windows XP Professional Den Computer / Laptop einschalten und Windows XP Professional Installations CD

Mehr

Benutzerhandbuch / User s Manual RUPS 2000 / -B1

Benutzerhandbuch / User s Manual RUPS 2000 / -B1 RUPS 2000 / RUPS 2000-B1 Benutzerhandbuch / User s Manual RUPS 2000 / -B1 Deutsch English Benutzerhandbuch RUPS 2000 / RUPS 2000-B1 Deutsch In diesem Benutzerhandbuch finden Sie eine Kurzanleitung zu Installation

Mehr

B4 Viper Connector Service Installationsanleitung Stand: 2013-07- 16

B4 Viper Connector Service Installationsanleitung Stand: 2013-07- 16 B4 Viper Connector Service Installationsanleitung Stand: 2013-07- 16 Inhalt 1 ALLGEMEINES... 2 2 INSTALLATION DES VIPER CONNECTOR SERVICE... 3 3 EINRICHTUNG DES TEILNEHMERACCOUNTS... 5 4 INSTALLATION DES

Mehr

Wichtige Hinweise zu den neuen Orientierungshilfen der Architekten-/Objektplanerverträge

Wichtige Hinweise zu den neuen Orientierungshilfen der Architekten-/Objektplanerverträge Wichtige Hinweise zu den neuen Orientierungshilfen der Architekten-/Objektplanerverträge Ab der Version forma 5.5 handelt es sich bei den Orientierungshilfen der Architekten-/Objektplanerverträge nicht

Mehr

1. Double click on the Actisys USB icon Found on Floppy A:\

1. Double click on the Actisys USB icon Found on Floppy A:\ WARNING:- Make sure that the ACTISYS FIR-USB adapter is not plugged in before installing this Software. ACHTUNG:- Den ACTISYS FIR-USB-Adapter KEINESFALLS vor der Installation der Software anschließen!

Mehr

NetSeal Pro. Installations- und Bedienungsanweisung. Printserver L1 USB. Höns-Electronic GmbH & Co KG Bremen www.hoens-electronic.

NetSeal Pro. Installations- und Bedienungsanweisung. Printserver L1 USB. Höns-Electronic GmbH & Co KG Bremen www.hoens-electronic. NetSeal Pro Installations- und Bedienungsanweisung Printserver L1 USB Höns-Electronic GmbH & Co KG Bremen www.hoens-electronic.de Inhalt Inhalt...2 Vorbereitungen...3 Allgemeines... 3 Installation der

Mehr

ISi. ISi Technologie GmbH. MET -Schnittstelle zu Davis WeatherLink Version 5.7

ISi. ISi Technologie GmbH. MET -Schnittstelle zu Davis WeatherLink Version 5.7 ISi ISi Technologie GmbH MET -Schnittstelle zu Davis WeatherLink Version 5.7 Einleitung Die MET -Schnittstelle zur Davis -WeatherLink Software Version 5.7 oder höher erlaubt die Online-Uebernahme der Wetterdaten

Mehr

SanStore: Kurzanleitung / SanStore: Quick reference guide

SanStore: Kurzanleitung / SanStore: Quick reference guide SanStore Rekorder der Serie MM, MMX, HM und HMX Datenwiedergabe und Backup Datenwiedergabe 1. Drücken Sie die Time Search-Taste auf der Fernbedienung. Hinweis: Falls Sie nach einem Administrator-Passwort

Mehr

Anweisungen zur Installation und Entfernung von Windows PostScript- und PCL-Druckertreibern Version 8

Anweisungen zur Installation und Entfernung von Windows PostScript- und PCL-Druckertreibern Version 8 Anweisungen zur Installation und Entfernung von Windows PostScript- und PCL-Druckertreibern Version 8 Diese README-Datei enthält Anweisungen zum Installieren des Custom PostScript- und PCL- Druckertreibers

Mehr

Installation Manual. Driver Installation USB-to-Serial Adapter WE2111. A en/de

Installation Manual. Driver Installation USB-to-Serial Adapter WE2111. A en/de Installation Manual English Deutsch Driver Installation USB-to-Serial Adapter WE2111 A4012-1.0 en/de USB-to-Serial Adapter English 2 A4012-1.0 en/de USB-to-Serial Adapter 1 Installation in Windows 7...

Mehr

Einrichtung des Cisco VPN Clients (IPSEC) in Windows7

Einrichtung des Cisco VPN Clients (IPSEC) in Windows7 Einrichtung des Cisco VPN Clients (IPSEC) in Windows7 Diese Verbindung muss einmalig eingerichtet werden und wird benötigt, um den Zugriff vom privaten Rechner oder der Workstation im Home Office über

Mehr

Allgemeine Eigenschaften von SESAM Vertrag Professional

Allgemeine Eigenschaften von SESAM Vertrag Professional SESAM- Seite 1 SESAM-Vertragsverwaltung - die ersten Schritte Seite 1 Allgemeine Eigenschaften von SESAM Vertrag Professional SESAM - Vertrag Professional dient zur einfachen Erstellung und Verwaltung

Mehr

Installation mit Lizenz-Server verbinden

Installation mit Lizenz-Server verbinden Einsteiger Fortgeschrittene Profis markus.meinl@m-quest.ch Version 1.0 Voraussetzungen für diesen Workshop 1. Die M-Quest Suite 2005-M oder höher ist auf diesem Rechner installiert 2. Der M-Lock 2005 Lizenzserver

Mehr

https://portal.microsoftonline.com

https://portal.microsoftonline.com Sie haben nun Office über Office365 bezogen. Ihr Account wird in Kürze in dem Office365 Portal angelegt. Anschließend können Sie, wie unten beschrieben, die Software beziehen. Congratulations, you have

Mehr

Für Windows 7 Stand: 21.01.2013

Für Windows 7 Stand: 21.01.2013 Für Windows 7 Stand: 21.01.2013 1 Überblick Alle F.A.S.T. Messgeräte verfügen über dieselbe USB-Seriell Hardware, welche einen Com- Port zur Kommunikation im System zur Verfügung stellt. Daher kann bei

Mehr

Handbuch. Artologik EZ-Equip. Plug-in für EZbooking version 3.2. Artisan Global Software

Handbuch. Artologik EZ-Equip. Plug-in für EZbooking version 3.2. Artisan Global Software Artologik EZ-Equip Plug-in für EZbooking version 3.2 Artologik EZbooking und EZ-Equip EZbooking, Ihre webbasierte Software zum Reservieren von Räumen und Objekten, kann nun durch die Ergänzung um ein oder

Mehr

CLX.ScanPackage Quick Install Guide und Erste Schritte

CLX.ScanPackage Quick Install Guide und Erste Schritte CLX.ScanPackage Quick Install Guide und Erste Schritte 1. Vorbereitungen für die Installation Entfernen Sie die bestehende Maus und hängen den LG MOUSE SCANNER an Ihrem PC an Entfernen Sie den Schutzkleber

Mehr

Konfigurationsanleitung Access Control Lists (ACL) Funkwerk. Copyright Stefan Dahler - www.neo-one.de 13. Oktober 2008 Version 1.0.

Konfigurationsanleitung Access Control Lists (ACL) Funkwerk. Copyright Stefan Dahler - www.neo-one.de 13. Oktober 2008 Version 1.0. Konfigurationsanleitung Access Control Lists (ACL) Funkwerk Copyright Stefan Dahler - www.neo-one.de 13. Oktober 2008 Version 1.0 Seite - 1 - 1. Konfiguration der Access Listen 1.1 Einleitung Im Folgenden

Mehr

Installationsanleitung LogControl DL-Software

Installationsanleitung LogControl DL-Software Installationsanleitung LogControl DL-Software Version 1.0.2.17 1. Einleitung Bitte lesen Sie die Installationsanleitung zuerst aufmerksam durch, bevor Sie mit der Installation der LogControl DL-Software

Mehr

Klicken Sie mit einem Doppelklick auf das Symbol Arbeitsplatz auf Ihrem Desktop. Es öffnet sich das folgende Fenster.

Klicken Sie mit einem Doppelklick auf das Symbol Arbeitsplatz auf Ihrem Desktop. Es öffnet sich das folgende Fenster. ADSL INSTALLATION WINDOWS 2000 Für die Installation wird folgendes benötigt: Alcatel Ethernet-Modem Splitter für die Trennung Netzwerkkabel Auf den folgenden Seiten wird Ihnen in einfachen und klar nachvollziehbaren

Mehr

web: www.ncgraphics.de CAD/CAM-Systeme Entwicklung Beratung Vertrieb Kundenbetreuung Service für Werkzeugmaschinen

web: www.ncgraphics.de CAD/CAM-Systeme Entwicklung Beratung Vertrieb Kundenbetreuung Service für Werkzeugmaschinen DNC Software für Windows Version 2.0 Installation der Software Starten Sie die Datei DNC-Install.exe auf der Diskette / CD und folgen den Installationsanweisungen. Start der Software Beim ersten Start

Mehr

CLX.ScanPackage Quick Install Guide und Erste Schritte

CLX.ScanPackage Quick Install Guide und Erste Schritte CLX.ScanPackage Quick Install Guide und Erste Schritte 1. Vorbereitungen für die Installation Entfernen Sie die bestehende Maus und verbinden Sie den LG MOUSE SCANNER an Ihrem PC an Entfernen Sie den Schutzkleber

Mehr

miditech 4merge 4-fach MIDI Merger mit :

miditech 4merge 4-fach MIDI Merger mit : miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse

Mehr

Wie verbindet man Nokia 6600 mit Oxygen Phone Manager II for Symbian OS phones ( http://www.opm-2.com/symbian/ )

Wie verbindet man Nokia 6600 mit Oxygen Phone Manager II for Symbian OS phones ( http://www.opm-2.com/symbian/ ) Wie verbindet man Nokia 6600 mit Oxygen Phone Manager II for Symbian OS phones ( http://www.opm-2.com/symbian/ ) Falls Sie Ihr Telefon mit dem Rechner paarsweise schon verbunden haben, bitte sehen Sie

Mehr

ReadMe zur Installation der BRICKware for Windows, Version 6.1.2. ReadMe on Installing BRICKware for Windows, Version 6.1.2

ReadMe zur Installation der BRICKware for Windows, Version 6.1.2. ReadMe on Installing BRICKware for Windows, Version 6.1.2 ReadMe zur Installation der BRICKware for Windows, Version 6.1.2 Seiten 2-4 ReadMe on Installing BRICKware for Windows, Version 6.1.2 Pages 5/6 BRICKware for Windows ReadMe 1 1 BRICKware for Windows, Version

Mehr

Installation unter Windows

Installation unter Windows Die Installation der Programme beginnt mit der Überprüfung des Inhalts Ihrer Lieferung. Bitte vergleichen Sie den Inhalt Ihrer Lieferung mit den gekennzeichneten Artikeln: KHA Master Installer DVD (Windows)

Mehr

Titelbild1 ANSYS. Customer Portal LogIn

Titelbild1 ANSYS. Customer Portal LogIn Titelbild1 ANSYS Customer Portal LogIn 1 Neuanmeldung Neuanmeldung: Bitte Not yet a member anklicken Adressen-Check Adressdaten eintragen Customer No. ist hier bereits erforderlich HERE - Button Hier nochmal

Mehr

Herzlich willkommen bei der Installation des IPfonie -Softclients!

Herzlich willkommen bei der Installation des IPfonie -Softclients! Herzlich willkommen bei der Installation des IPfonie -Softclients! Sie benötigen diesen Softclient, um mit Ihrem Computer bequem über Ihren Internetanschluss telefonieren zu können. Der Softclient ist

Mehr

Daten fu r Navigator Mobile (ipad)

Daten fu r Navigator Mobile (ipad) [Kommentare] Inhalte Navigator Mobile für das ipad... 3 Programme und Dateien... 4 Folgende Installationen sind erforderlich:... 4 Es gibt verschiedene Dateiformate.... 4 Die Installationen... 5 Installation

Mehr

Remotely Anywhere Verwendung von Zertifikaten Schritt für Schritt Anleitung zur Implementation von Zertifikaten in Remotely Anywhere

Remotely Anywhere Verwendung von Zertifikaten Schritt für Schritt Anleitung zur Implementation von Zertifikaten in Remotely Anywhere Remotely Anywhere Verwendung von Zertifikaten Schritt für Schritt Anleitung zur Implementation von Zertifikaten in Remotely Anywhere Copyright 1997-2005 Brainware Consulting & Development AG All rights

Mehr

Installation / Aktualisierung von Druckertreibern unter Windows 7

Installation / Aktualisierung von Druckertreibern unter Windows 7 Rechenzentrum Installation / Aktualisierung von Druckertreibern unter Windows 7 Es gibt drei verschiedene Wege, um HP-Druckertreiber unter Windows7 zu installieren: (Seite) 1. Automatische Installation...

Mehr

Workflow. Installationsanleitung

Workflow. Installationsanleitung Workflow Installationsanleitung August 2013 Inhaltsverzeichnis Kapitel 1 Installation der Programme... 2 Kapitel 2 Lizenzierung Novaline Workflow... 4 Kapitel 3 Einrichten der Systeme... 5 3.1 Workflow

Mehr

Securepoint Security Systems

Securepoint Security Systems HowTo: Virtuelle Maschine in VMware für eine Securepoint Firewall einrichten Securepoint Security Systems Version 2007nx Release 3 Inhalt 1 VMware Server Console installieren... 4 2 VMware Server Console

Mehr

Windows Server 2012 R2 Essentials & Hyper-V

Windows Server 2012 R2 Essentials & Hyper-V erklärt: Windows Server 2012 R2 Essentials & Hyper-V Windows Server 2012 R2 Essentials bietet gegenüber der Vorgängerversion die Möglichkeit, mit den Boardmitteln den Windows Server 2012 R2 Essentials

Mehr

FuxMedia Programm im Netzwerk einrichten am Beispiel von Windows 7

FuxMedia Programm im Netzwerk einrichten am Beispiel von Windows 7 FuxMedia Programm im Netzwerk einrichten am Beispiel von Windows 7 Die Installation der FuxMedia Software erfolgt erst NACH Einrichtung des Netzlaufwerks! Menüleiste einblenden, falls nicht vorhanden Die

Mehr

JTAGMaps Quick Installation Guide

JTAGMaps Quick Installation Guide Index Index... 1 ENGLISH... 2 Introduction... 2 Requirements... 2 1. Installation... 3 2. Open JTAG Maps... 4 3. Request a free JTAG Maps license... 4 4. Pointing to the license file... 5 5. JTAG Maps

Mehr

Installation der SAS Foundation Software auf Windows

Installation der SAS Foundation Software auf Windows Installation der SAS Foundation Software auf Windows Der installierende Benutzer unter Windows muss Mitglied der lokalen Gruppe Administratoren / Administrators sein und damit das Recht besitzen, Software

Mehr

LPT1 Anschluss mit PCMCIA Karte

LPT1 Anschluss mit PCMCIA Karte 1. Allgemeines LPT1 Anschluss mit PCMCIA Karte verwendete Hardware: Lenze PC Systembusadapter EMF 2173-V003 PCMCIA Karte Firma QUATECH Typ SPP-100 Auf die Installation der PCMCIA Karte wird hier nicht

Mehr

Installation des COM Port Redirectors

Installation des COM Port Redirectors Installation des COM Port Redirectors Über die entsprechenden Treiber ist es möglich, die seriellen Schnittstellen eines IGW/400 als virtuelle COM-Ports eines Windows-PCs zu nutzen. Aus Sicht der PC-Software

Mehr

Artikel Schnittstelle über CSV

Artikel Schnittstelle über CSV Artikel Schnittstelle über CSV Sie können Artikeldaten aus Ihrem EDV System in das NCFOX importieren, dies geschieht durch eine CSV Schnittstelle. Dies hat mehrere Vorteile: Zeitersparnis, die Karteikarte

Mehr

BLK-2000. Quick Installation Guide. English. Deutsch

BLK-2000. Quick Installation Guide. English. Deutsch BLK-2000 Quick Installation Guide English Deutsch This guide covers only the most common situations. All detail information is described in the user s manual. English BLK-2000 Quick Installation Guide

Mehr

IDEP / KN8 für WINDOWS. Schnellstart

IDEP / KN8 für WINDOWS. Schnellstart IDEP / KN8 für WINDOWS Schnellstart 1. INSTALLATION 1.1 ÜBER DAS INTERNET Auf der Webseite von Intrastat (www.intrastat.be) gehen Sie nach der Sprachauswahl auf den Unterpunkt Idep/Gn8 für Windows. Dann

Mehr

SmartClass Firmware-Update Vorgehensweise

SmartClass Firmware-Update Vorgehensweise Benutzeranweisungen SmartClass Firmware-Update Vorgehensweise 2008.01 (V 1.x.x) Deutsch Please direct all enquiries to your local JDSU sales company. The addresses can be found at: www.jdsu.com/tm-contacts

Mehr

Wir wünschen Ihnen viel Freude und Erfolg mit Ihrem neuen X-PRO-USB-Interface. Ihr Hacker-Team

Wir wünschen Ihnen viel Freude und Erfolg mit Ihrem neuen X-PRO-USB-Interface. Ihr Hacker-Team Installationsanleitung Hacker X-PRO-USB-Controller V2 Software + Interface Sehr geehrter Kunde, wir freuen uns, dass Sie sich für das X-PRO-USB-V2-Interface aus unserem Sortiment entschieden haben. Sie

Mehr

2. Die eigenen Benutzerdaten aus orgamax müssen bekannt sein

2. Die eigenen Benutzerdaten aus orgamax müssen bekannt sein Einrichtung von orgamax-mobil Um die App orgamax Heute auf Ihrem Smartphone nutzen zu können, ist eine einmalige Einrichtung auf Ihrem orgamax Rechner (bei Einzelplatz) oder Ihrem orgamax Server (Mehrplatz)

Mehr

METTLER TOLEDO USB-Option Installation der Treiber unter Windows XP

METTLER TOLEDO USB-Option Installation der Treiber unter Windows XP Diese Anleitung beschreibt den Ablauf bei der Installation und Deinstallation der Treiber für die METTLER TOLEDO USB-Option unter Windows XP. Die USB-Option wird als zusätzliche serielle Schnittstelle

Mehr

Handbuch PCI Treiber-Installation

Handbuch PCI Treiber-Installation Handbuch PCI Treiber-Installation W&T Release 1.0, September 2003 09/2003 by Wiesemann & Theis GmbH Microsoft und Windows sind eingetragene Warenzeichen der Microsoft Corporation Irrtum und Änderung vorbehalten:

Mehr

Betriebssystem Windows - SSH Secure Shell Client

Betriebssystem Windows - SSH Secure Shell Client Betriebssystem Windows - SSH Secure Shell Client Betriebssystem Windows - SSH Secure Shell Client... 1 Download... 2 Installation... 2 Funktionen... 3 Verbindung aufbauen... 3 Verbindung trennen... 4 Profile...

Mehr

Cisco AnyConnect VPN Client - Anleitung für Windows7

Cisco AnyConnect VPN Client - Anleitung für Windows7 Cisco AnyConnect VPN Client - Anleitung für Windows7 1 Allgemeine Beschreibung 2 2 Voraussetzungen für VPN Verbindungen mit Cisco AnyConnect Software 2 2.1 Allgemeine Voraussetzungen... 2 2.2 Voraussetzungen

Mehr

Psyprax GmbH. Netzwerk Installation unter XP. Wichtig für alle Netzwerkinstallationen: Psyprax GmbH

Psyprax GmbH. Netzwerk Installation unter XP. Wichtig für alle Netzwerkinstallationen: Psyprax GmbH Netzwerk Installation unter XP Wichtig für alle Netzwerkinstallationen: Während des Betriebs ist es nicht möglich die Firebird-Datenbank (psyprax.fdb usw.) zu kopieren. Insbesondere Techniken wie die Festplattenspiegelung

Mehr

How to install freesshd

How to install freesshd Enthaltene Funktionen - Installation - Benutzer anlegen - Verbindung testen How to install freesshd 1. Installation von freesshd - Falls noch nicht vorhanden, können Sie das Freeware Programm unter folgendem

Mehr

Anbinden der Visualisierung GILLES TOUCH (VNC)

Anbinden der Visualisierung GILLES TOUCH (VNC) Anbinden der Visualisierung GILLES TOUCH (VNC) Seite 1 von 19 Inhalt 1. Ermitteln der internen IP-Adresse... 3 2. Einstellen der IP-Adresse an der Gilles-Touch Regelung... 6 3. Installieren des Fernwartungsprogramms

Mehr

i Korrekturlauf mit Acrobat Reader - Correction workflow using Acrobat Reader i.1 Vorbereitung / Preparations

i Korrekturlauf mit Acrobat Reader - Correction workflow using Acrobat Reader i.1 Vorbereitung / Preparations IPPS UND RICKS KORREKURLAUF MI ACROBA READER - CORRECION WORKFLOW USING ACROBA READER i Korrekturlauf mit Acrobat Reader - Correction workflow using Acrobat Reader i.1 Vorbereitung / Preparations VOREINSELLUNGEN

Mehr