EA-PS W Single/Double/Triple 19 AC/DC EINSCHUBNETZTEILE 19 AC/DC PLUG-IN POWER SUPPLIES
|
|
- Nelly Straub
- vor 6 Jahren
- Abrufe
Transkript
1 19 AC/DC EISCHUBETZTEIE 19 AC/DC PUGI POWER SUPPIES EAPS 00 0W Single/Double/Triple EAElektroAutomatik GmbH & Co. KG Entwicklung Produktion Vertrieb Helmholtzstraße Viersen Telefon: 0 / Telefax: 0 / 2 ea197@elektroautomatik.de EAPS 030 Single : EAPS 050 Single: EAPS 0 Single: EAPS 0 Single: EAPS 050 Double: 0 1 EAPS 050 Double S01: EAPS 050 Double: EAPS 050 Double S01: EAPS 0 Double: 0 1 EAPS 0 Double: EAPS 050 Triple: 0 1
2
3 Technical specifications PS 030 Single PS 050 Single PS 0 Single PS 0 Single E Über die Geräte EAPS AC/DC EISCHUBETZTEIE 0W oad regulation 0...0% Iout ine regulation 0% Iout Regulation time 0% load signal Article o. 3,3V (3,0...3,V) 5V (,...5,5V) 3,...,5V,0...,7V A / 5W A / 0W external on/off external on/off PS 050 Double V (11,...15,2V) V (23,5...2,5V),5...,0V 29,0...33,0V 7,5A / 90W A / 9W <,5A <,A external on/off external on/off PS 050 Double (S01) Allgemeines Die etzgeräte der Serie EAPS 000 sind für den Einbau in 19 Aufbausysteme nach DI9 konzipiert. Sie sind in stabilen Gehäusen mit einer Aluminiumfrontplatte von 3HE Höhe und TE Breite untergebracht. Der elektrische Anschluß ist mit einem Steckverbinder nach DI vom Typ H15 in Position 1 realisiert. Die Geräte sind von höchster Qualität und entsprechen den Sicherheitsnormen E0950 (TÜV) und U, sowie der EMVorm E550. Betriebsspannung Alle Modelle sind mit einer aktiven PFC (Power Factor Correction) ausgerüstet und verfügen somit über einen weiten Eingangsspannungsbereich. Sie können mit ACEingangsspannungen von 90V bis 2V und einer Frequenz von 5Hz bis 5HZ oder mit DCEingangsspannungen von 90V bis 30V betrieben werden. Der Einschaltstrom wird durch einen TCWiderstand auf <23A begrenzt, sowie Eingangsspannungsspitzen durch einen VDRWiderstand. oad regulation 0...0% Iout ine regulation 0% Iout Regulation time 0% load signal Article o. 5V (,...5,5V) V (11,...15,2V),0...,7V,5...,0V A / 0W 2,5A external on/off or ASF 01 (S01: 0901) 5V (,...5,5V) V (23,...27,2V),0...,7V 33,0...3,0V A / 0W 2,5A external on/off or ASF 015 (S01: 09015) eistungsausgänge Alle zur Verfügung stehenden en sind in bestimmten Bereichen, durch entsprechende Öffnungen in der Frontplatte, mit Hilfe eines geeigneten Schraubendrehers einstellbar. Alle Ausgänge sind spannungsgeregelt, kuzschluß und überlastfest. Die Betriebsbereitschaft der Ausgänge wird jeweils durch eine grüne ED signalisiert. Zum Schutz angeschlossener Verbraucher, sind die Geräte mit einem Überspannungsschutz (OVP) ausgestattet. Wenn eine fest eingestellte Überspannungsschwelle überschritten wird, werden alle Ausgänge abgeschaltet. Die Geräte verfügen über einen Übertemperaturschutz (OT), der bei zu hohen Temperaturen alle Ausgänge abschaltet. Mechanische Abmessungen PS 0 Double PS 0 Double oad regulation 0...0% Iout ine regulation 0% Iout Regulation time 0% load signal Article o. V (11,...15,2V) V (11,...15,2V),5...,0V,5...,0V <,5A <3,0A external on/off 01 V (11,...15,2V) V (23,...27,2V),5...,0V 33,0...3,0V <,5A <3,0A external on/off 017 PS 050 Triple oad regulation 0...0% Iout ine regulation 0% Iout Regulation time 0% load signal Article o. 5V (,...5,5V) V (11,...15,2V) V (11,...15,2V) <0,2% <0,2% 0, ElektroAutomatik GmbH & Co. KG,0...,7V,5...,0V,5...,0V A / 0W 2,5A 2,5A <3,0A external on/off 0 Wichtige Informationen!! Vor der ersten Inbetriebnahme der Geräte müssen die Gehäuse, die Bedienund Anzeigeelemente und der Steckverbinder auf Beschädigungen hin überprüft werden. Werden Beschädigungen festgestellt, darf das Gerät nicht betrieben werden. Eine Reparatur oder Wartung darf nur von geschultem Fachpersonal durchgeführt werden. Die Geräte dürfen nur an einem etz mit Schutzleiter () betrieben werden. Die natürliche uftzirkulation darf an den uftschlitzen nicht behindert werden. Wenn die Geräte unter Dauerlast betrieben werden, werden Abstände von mindestens 0mm oben, und mm unten empfohlen. Die Stromversorgung darf nur in eingebauten Zustand in einem 19 Baugruppenträger nach DI 9 betrieben werden. Achtung!! Die Geräte können nach längerem Betrieb eine hohe Oberflächentemperatur erreichen. 3
4 Beschreibung SenseEingänge Alle Geräte verfügen, um Spannungsabfälle auf den astleitungen kompensieren zu können, serienmäßig über SenseEingänge (Fernfühlung) für die Hauptausgangsspannung V1. Wenn diese Funktion genutzt werden soll, müssen diese Anschlüsse direkt mit den Anschlüssen an der ast verbunden werden. Die Verbindung muß mit Hilfe eines zweiadrigen, möglichst verdrillten Kabels vorgenommen werden. Der Anschluß der eitungen muß polrichtig, d.h. Sense an und Sense an, erfolgen. Über die Senseleitungen darf kein Strom fl ießen, da sonst möglicherweise interne Komponenten zerstört werden könnten. Es können Spannungsabfälle bis maximal 0,5V auf jeder eitung kompensiert werden. Wenn keine Kompensation gewünscht wird müssen die Senseanschlüsse polrichtig direkt an den etzteilanschlüssen verbunden werden. Extern ein/aus Bei dieser Geräteserie besteht die Möglichkeit, über einen Eingang die Ausgänge ferngesteuert ein und auszuschalten, wodurch sich die Geräte auch in automatische Prüfabläufe einbinden lassen. Um die Ausgänge auszuschalten muß dieser Eingang auf gelegt werden. Bleibt dieser Eingang frei, sind die Geräte dauerhaft eingeschaltet. Wichtig: die Funktion Extern ein/aus steht bei Double oder TripleGeräten nicht zur Verfügung, wenn die Option Stromaufteilung (ASF) vorhanden ist! Temperaturverhalten Die Kühlung der Geräte erfolgt über Konvektion und ist für einen Umgebungstemperaturbereich von C ausgelegt. Ab einer Umgebungstemperatur von über 5 C muss von dem Anwender eine entsprechende, individuelle eistungsreduzierung vorgenommen werden. Aus Sicherheitsgründen sind die Geräte mit einer Übertemperaturabschaltung ausgestattet. Sollte die Übertemperaturabschaltung aktiv werden, wird der eistungsausgang abgeschaltet. Der eistungsausgang schaltet sich nach Abkühlung des Gerätes automatisch wieder ein. Stromaufteilung Um bei einem möglichen Parallelbetrieb der Singlespannungsgeräte eine optimale Stromaufteilung zu erreichen, können diese Geräte auch mit einem ASFEingang ausgestattet sein. Im Bedarfsfall müssen diese Anschlüsse der einzelnen Geräte dann ebenfalls parallel geschaltet werden. Mit dieser Funktion kann so ein redundantes Versorgungssystem aufgebaut werden. 0, ASF ElektroAutomatik GmbH & Co. KG Betrieb mit Kompensation etzteil ast, etzteil ast, Betrieb ohne Kompensation Ext. O/OFF etzteil OFF O,, ast,, Technical description Error output PF (Power Fail) If a power fail error occurs (e.g. mains blackout ) this open collector output will be pulled to GD via a 1kOhm resistor. After that, the output voltage V1 will still be provided for at least 5ms. A limit of V DC and ma on this output may be not exceeded. Schematic diagram PSU PF 1 Kohm, max V DC max ma Technical specifications Connections of H15 plug AC input 2 and AC filter AC input voltage Frequency DC input voltage Power factor of PFC Overall effiency Input surge current limitation Input voltage spike limitation Backup time Output power in dependency of type Ambient temperature Temperature vs. Power derating for natural convection for forced air 1m/s Storage temperature Relative humidity (no condensation) Safety: CE marking according to low voltage directive 73/23/EEG Safety according to EMC: CE marking according to EMC directive 9/33/EEG EMI conducted & radiated emission EMI humidity Dimensions (D x W x H) Weight Power factor correction (PFC) DC/DC Converter control,, V V Sense Sense Extern off / ASF V2 ASF / GD V2, V3 E ote about special version S01: EAPS W At this version, output V2 (V) is additionally led out on pin, in order to gain V compatibility to other manufacturers Hz V > up to 9% 2 <23A by TC by VDR >ms Pin Single Double Double V Triple 5W...9W C >5 C 2,1W/ C >0 C,0W/ C 0 C... 5 C 90% max. Sense Sense Sense Sense Sense Sense Sense Sense V2 V2 V2 ASF (opt.) GD V2 V2 (only S01) GD V2/V3 E 0950, IEC 950 GD V2 V3 Extern off Extern off / ASF 1 Extern off / ASF 1 Extern off / ASF 1 2 E 003 E 002 2mm x HP x 3HE 2 0g 1) Optional, also see page V3 (PF) 9
5 Technical description Sense input For a compensation of voltage drops on the high power leads from the power supply to the load, all units are equipped with remote sense inputs for the main output voltage V1. By using this function, the sense inputs must be connected directly to the load terminals via a 2core cable (if possible, twisted pair), with attention to the correct polarity (Sense to and Sense to ). o current may be drawn through the sense cables, because otherwise internal components could be damaged. The maximum compensation of voltage drops is max. 0,5V per power lead. If no compensation is wanted, the sense inputs have to be connected directly to the power output connectors of V1, also with attention to the correct polarity. Extern off To realise a remote on/off function, a special input is available. To switch off all available outputs, this input must be connected or switched to GD of V1. If this input is not connected, all outputs are permanently switched on. This function makes it possible to use this unit also in automatic test applications. ote: On double and triple output models with implementated current sharing (ASF) option, the external on/off function is not available. Temperature Cooling of the units is realised by convection for an ambient temperature range of 0 C up to 70 C. If the ambient temperature exceeds 5 C, the user has to reduce the load proportionally to the ambient temperature. The units are overtemperature protected. In case of an overtemperature, the power outputs are shut down. After cooling down, the power output will be switch on again automatically. Current sharing with ASF () To gradually increase system power, two or more power supply units can be connected in parallel. By using the ASF inputs/outputs, which are also connected in parallel, an effective current sharing is possible. With this, a redundant power supply system can be built. Operation with compensation Power supply, oad Power supply oad, Operation without compensation Ext. off Power supply OFF O /, 0, ElektroAutomatik GmbH & Co. KG oad, E Beschreibung Fehlermeldeausgang Über diesen Ausgang kann ein etzausfall detektiert werden. Dieser Ausgang ist ein open collector Ausgang, der im Fehlerfall über einen 1kOhm Schutzwiderstand auf GD geschaltet wird, während die V1 danach noch für einen Zeitraum von mindestens zur Verfügung steht. Die Schaltspannung an diesem Ausgang darf V DC nicht überschreiten. Der maximale Schaltstrom beträgt ma. Prinzipschaltbild AC Eingang 2 und AC Filter Allgemeine eistungsfaktorkorrektur (PFC) EAPS W ACEingangsspannung V Frequenz 5...5Hz DCEingangsspannung V eistungsfaktor PFC >0,99 Wirkungsgrad bis 9% Einschaltstrombegrenzung <23A mit TC Begrenzung Eingangsspannungsspitzen durch VDR etzausfallüberbrückung >ms Ausgangsleistung je nach Modell 5W... 9W Umgebungstemperatur C Temperatur / Ausgangsleistung Derating für natürliche Konvektion V1 = 5V >5 C 2,5W/ C V2 = V >5 C 2,3W/ C V3 = V >5 C 2,0W/ C für forcierte Kühlung 1m/s V1 = 5V >0 C,0W/ C V2 = V >0 C 5,0W/ C V3 = V >0 C,0W/ C agertemperatur 0 C... 5 C Relative uftfeuchtigkeit (keine Betauung) 90% max. Sicherheit: CEZeichen gemäß iederspannungsrichtlinie 73/23/EWG Sicherheit gemäß E 0950, IEC 950 EMV: CEZeichen gemäß EMVRichtlinie 9/33/EWG EMVStöraussendung E 003 EMVStörfestigkeit E 002 Abmessungen (H x B x T) 3HE x TE x 2mm Gewicht 0g DC/DC Wandler etzteil PF 1 Kohm,, control, max V DC max ma V Sense Sense Extern aus / ASF V2 ASF / GD V2, V3 V3 (PF) V Anschlußbelegung H15 Buchsenleiste Hinweis zur Sonderversion S01: Hier ist Ausgang V2 (V) zusätzlich auf Pin herausgeführt, um eine Kompatibilität zu anderen Herstellern zu erreichen. Pin Single Double 2 Double V 2 Triple Sense Sense Sense Sense Sense Sense Sense Sense V2 V2 V2 ASF (opt.) GD V2 V2 (nur S01) GD V2/V3 GD V2 V3 Extern aus Extern aus / ASF 1 Extern aus / ASF 1 Extern aus / ASF 1 2 2, 1) Optional, siehe auch Seite 5
6 PS 030 Single PS 050 Single PS 0 Single PS 0 Single About the units EAPS AC/DC PUG I POWER SUPPIES 0W astregelung 0...0% Iout etzregelung 0% Iout Ausregelzeit 0% ast Ausgangsstrom / leistung etzausfallsignal Artikel r. astregelung 0...0% Iout etzregelung 0% Iout Ausregelzeit 0% ast Ausgangsstrom / leistung etzausfallsignal Artikel r. 3,3V (3,0...3,V) 5V (,...5,5V) 3,...,5V,0...,7V A / 5W A / 0W extern ein/aus extern ein/aus PS 050 Double (S01) 5V (,...5,5V) V (11,...15,2V),0...,7V,5...,0V A / 0W 2,5A extern ein/aus oder ASF 01 V (11,...15,2V) V (23,5...2,5V),5...,0V 29,0...33,0V 7,5A / 90W A / 9W <,5A <,A extern ein/aus extern ein/aus PS 050 Double (S01) 5V (,...5,5V) V (23,...27,2V),0...,7V 33,0...3,0V A / 0W 2,5A extern ein/aus oder ASF 015 (S01: 09015) General The power supplies of the series EAPS 000 are designed as plugin units for 19 drawout systems according to DI 9. They are assembled in a stable housing with a aluminium front panel in dimension of 3U / HP. The electrical connection is realised via a H15 plug, according to DI. The power supplies are manufactured for highest quality and accordance to safety standards E 0950 (TÜV) and U and the EMI standard E 550. Input voltage All power supplies are equipped with an active PFC (power factor correction) for use on a wide input voltage range. Thus the units can be used on mains AC voltages from 90V up to 2V and 5Hz up to 5Hz or DC voltages from 90V up to 30V. Input surge current will be limited to <23A by a TC resistor. Input voltage peaks are suppressed by a VDR resistor. Outputs All output voltages are adjustable in the defi ned range through the holes in the front panel and by using a screwdriver. The outputs are voltage regulated, overload and shortcircuit protected. A green ED for each output signalises, that the respective output is working correctly. To protect connected loads and equipments against overvoltage, an overvoltage protection circuit (OVP) is implemented. Also, an overtemperature protection feature (OT) is present. If the overtemperature limit is exceeded, all outputs will be shut down. Mechanical dimensions PS 0 Double PS 0 Double astregelung 0...0% Iout etzregelung 0% Iout Ausregelzeit 0% ast Ausgangsstrom / leistung etzausfallsignal Artikel r. V (11,...15,2V) V (11,...15,2V),5...,0V,5...,0V <,5A <3,0A extern ein/aus 01 V (11,...15,2V) V (23,...27,2V),5...,0V 33,0...3,0V <,5A <3,0A extern ein/aus 017 PS 050 Triple astregelung 0...0% Iout etzregelung 0% Iout Ausregelzeit 0% ast Ausgangsstrom / leistung etzausfallsignal Artikel r. 5V (,...5,5V) V (11,...15,2V) V (11,...15,2V) <0,2% <0,2% 0, ElektroAutomatik GmbH & Co. KG,0...,7V,5...,0V,5...,0V A / 0W 2,5A 2,5A <3,0A extern ein/aus 0 Important information Before the unit is put into operation, it is necessary to inspect the housing and electrical connectors for signs of physical damage. If any physical damage has been found, the equipment may be not connected to the mains. Repair and services must only be carried out by qualified and authorised personnel. The unit must only be operated at a grounded mains connection. The natural air circulation may not be impeded. Distances of 0mm at the top and mm at the bottom are recommended as minimum if the unit is operated with a constant load. The unit may be only used and fit into a subrack system according DI 9. Attention!! The housing and the front panel can become hot if the unit is in operation. 7
EA-PS 800. 240W Single/Double/Triple 19 AC/DC EINSCHUBNETZTEILE 19 AC/DC PLUG-IN POWER SUPPLIES
19 AC/DC EINSCHUBNETZTEILE 19 AC/DC PLUG-IN POWER SUPPLIES EA-PS 800 240W Single/Double/Triple Abbildung ähnlich / Actual product not shown EA-PS 803-240 Single : 08 130 318 EA-PS 805-240 Single: 08 130
MehrGK-Serie MONOVOLT. DC/DC-Wandler
GK-Serie: MONOVOLT DC/DC-Wandler 30 bis 120 Watt primärgetaktete DC/DC-Einschubwandler mit einer in 3HE-Eurokassetten für den Einsatz in 19"-Baugruppenträgern nach DIN41494 Kompakter Aufbau in stabiler
MehrEA-PS 800 19 80W - 240W 19 DC-EINSCHUBNETZTEILE ALS EUROKASSETTE / 19 PLUG-IN DC POWER SUPPLIES AS EURO CASSETTE
19 DC-EINSCHUBNETZTEILE ALS EUROKASSETTE / 19 PLUG-IN DC POWER SUPPLIES AS EURO CASSETTE EA-PS 800 19 Weiteingangsbereich 90...264V mit aktiver PFC Hoher Wirkungsgrad bis 92% Ausgangsleistungen: 58W bis
MehrINSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示
BEDIENUNGSANLEITUNG To comply with the published safety standards, the following must be observed when using this power supply. Um den zur Zeit gültigen Sicherheitsbestimmungen zu genügen, müssen die nachstehenden
MehrDC/DC Converter 400 W
Eingangsbereich 4 : 1 Input Range 4 : 1 Wirkungsgrad bis 90 % Efficiency up to 90 % Full Brick Gehäuse Full Brick Case Eingangs-π-Filter Input-π-Filter Beschreibung 10 DC/DC-Wandler stehen in der Serie
MehrUWC 8801 / 8802 / 8803
Wandbedieneinheit Wall Panel UWC 8801 / 8802 / 8803 Bedienungsanleitung User Manual BDA V130601DE UWC 8801 Wandbedieneinheit Anschluss Vor dem Anschluss ist der UMM 8800 unbedingt auszuschalten. Die Übertragung
MehrAC/DC-Schaltnetzteile 100 W AC/DC Switching Power Supplies 100 W. Merkmale / Features. Eingangsbereich 90...264 V AC
E176177 Merkmale / Features Eingangsbereich 90...264 V AC / Universal Input 90...264 V AC Wirkungsgrad bis zu 90 % / Efficiency up to 90 % Full-Brick Gehäuse / Full Brick Package Aktiv PFC Funktion / Active
MehrPK-Serie MONOVOLT. AC/DC-Netzteile
PK-Serie: MONOVOLT AC/DC-Netzteile 30 bis 240 Watt primärgetaktete AC/DC-Einschubnetzteile mit einer in 3HE Eurokassetten für den Einsatz in 19"-Baugruppenträgern nach DIN41494 Eingangsdaten Eingangsspannung
MehrPSG 512 A. Stromversorgung / Power supply. Betriebstemperatur / Operation temperature C
Multischalter Green Line A Verstärker / Amplifier B Kopfstellen / Headends C Optische Komponenten Multischalter Green Line 5 IN Endmultischalter zur Verteilung von 4 SAT-ZF- (z.b. ASTRA) und terrestrischen
MehrLabornetzgerät Laboratory Power Supply
Labornetzgerät Laboratory Power Supply Art. Nb. 39 200 104 EA-PS 2316-050 / 2 x 16V/2 x 5,0A Art. Nb. 39 200 106 EA-PS 2332-025 / 2 x 32V/2 x 2,5A EA - ELEKTRO-AUTOMATIK Technische Daten / Technical Data
MehrMultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!
MultiPortSwitch VGA Umschalter Version 1.0 As of April 19 th 2004 Subject to change! Document version: Version Date Name Comment 1.00 29.03.2004 J. Klein Compiled Distributed by: idata industrielle Datensysteme
MehrABB i-bus EIB. EIB Power Supply Units
ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!
MehrCABLE TESTER. Manual DN-14003
CABLE TESTER Manual DN-14003 Note: Please read and learn safety instructions before use or maintain the equipment This cable tester can t test any electrified product. 9V reduplicated battery is used in
MehrBetriebsarten-Umschalter Common mode / Differential mode switch
Betriebsarten-Umschalter Common mode / Differential mode switch Beschreibung: Der Betriebsarten-Umschalter CMDM 87 erweitert die Messmöglichkeiten zweier V-Netznachbildungen um die einer T- und Delta-Netznachbildung.
MehrNPLC NPLC 8500 Netznachbildung NPLC 8500 Line Impedance Stabilization Network
NPLC 8500 Netznachbildung NPLC 8500 Line Impedance Stabilization Network Beschreibung: Die Netznachbildung NPLC 8500 wurde speziell für PLC-Messungen in Anlehnung an die ITU-T G.9901 entwickelt. Um die
MehrA VGA monitor of the highest resolution that you will be using on any computer in the installation A PS/2 Keyboard A PS/2 Mouse
PS/2 KVM SWITCH 2-PORT Vision 331217 Requirements Console A VGA monitor of the highest resolution that you will be using on any computer in the installation A PS/2 Keyboard A PS/2 Mouse Computers The following
MehrRS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät
Betriebsanleitung RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät ä 2 Operating Instructions RS232 Connection, RXU10 Setting up an RS232 connection
MehrVGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016
Overview The Hamburg Süd VGM-Portal is an application which enables to submit VGM information directly to Hamburg Süd via our e-portal web page. You can choose to insert VGM information directly, or download
MehrProduktinformation Access-Gateway. Product information Access gateway AGW 670-0
Produktinformation Access-Gateway Product information Access gateway AGW 670-0 1 2 3 4 2 Deutsch Anwendung Access-Gateway zur physikalischen Trennung von 2 Netzwerken an einem Access-Server. Durch den
MehrBZ 873. Trainline Interface. Ident Nr.: 3EH-116802 R0001
Ident Nr.: 3EH-116802 R0001 CH-8108 Dällikon Tel: +41(0)44 8440355 www.bahnelektronik.ch Seite: 1/8 Dritte oder andere Verwertung dieses Dokumentes sind ohne unsere ausdrückliche Zustimmung verboten. B+Z
MehrReflector Type STANDARD: Reflector Type CUSTOM:
options rot red blau blue grün green weiß (5600K) white warmweiß (3500K) warmwhite ultraweiß (6500K) ultrawhite RGB (nicht für Komplettlösungen verfügbar) RGB (not available for assembled solution) Ø 5
MehrAU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL
AU-D2 Coaxial/Optical Audio Converter OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Input Panel Diagram 2 3.2 Output Panel Diagram 2 3.3 Switcher
MehrAU-D21. Digital Audio Optical Switcher OPERATION MANUAL
AU-D21 Digital Audio Optical Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Front Panel Diagram 2 3.2 Rear Panel Diagram 2 3.3 Side
MehrAKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS
K la vi er l ac ko p tik AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS ZA 8970 DRUCKS0682.indd 1 05.09.12 15:15 VerpAckunGsinhAlT UKW / UHF / VHF Flachantenne
MehrE/A-Bedieneinheit. I/O Control unit 658552 DE/GB 08/02
E/A-Bedieneinheit I/O Control unit 527429 658552 DE/GB 08/02 Best.-Nr.: 658552 Benennung: DATENBLATT Bezeichnung: D:LP-BED.EINH.-E/A-DE/GB Stand: 08/2002 Autoren: Christine Löffler Grafik: Doris Schwarzenberger
MehrELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary
MehrBedienungsanleitung. User Manual
Bedienungsanleitung Seite: -3 User Manual LightmaXX 5ive STAR LED LIG0009669-000 Page: 4-5 Lieber Kunde, vielen Dank das Sie sich für ein Produkt von LightmaXX entschieden haben. In der folgenden Anleitung
MehrDELTA Multischalter / Multiswitches
Mulitschalter Profi Line / Multiswitchers Profi Line Mit der Profi Line wurde eine Schalterlinie entwickelt, die durch ihre exzellente Mechanik und Elektronik besticht. Die Umsetzung im Druckgussgehäuse
MehrKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
Mehr(825M) 2-Draht-Sender
Kamera SKS Bussystem 300004 (825M) 2-Draht-Sender 1. Installation Gefahr für Personen durch einen elektrischen Schlag. Verbrennungsgefahr, Geräteschäden und Fehlfunktionen. Bei der Installation sind die
MehrTW-75-IP40Trackball. Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40. Description
TW-75-IP40Trackball Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40 Description Applications: The advantages of this 75mm Trackball for back-panel-mounting are
MehrGS HYBRID SOLAR INVERTER / / AC-
www.geoprotek.com GS HYBRID SOLAR INVERTER Feed von Solar-und Batteriebetrieb, Grid-Backup, Built-in Transfer Switch / Solar Ladegerät / AC- Ladegerät, 500W ~ 3kW, reine Sinuswelle GS HYBRID ist die ideale
MehrTechnisches Datenblatt Spannungsversorgung
Schaltnetzteil 3-phasig geregelt, 2400 Watt Technische Änderungen vorbehalten 722814 Identifikation Typ CPSB3-2400-24 Eingangsseite Nennspannung 3 AC 400 500 V Arbeitsspannungsbereich AC 340 V 550 V/DC
MehrTomTom WEBFLEET Tachograph
TomTom WEBFLEET Tachograph Installation TG, 17.06.2013 Terms & Conditions Customers can sign-up for WEBFLEET Tachograph Management using the additional services form. Remote download Price: NAT: 9,90.-/EU:
MehrÜberspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden. Circuits using TVS Diodes
Überspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden Overvoltage Protection of Devices and Circuits using TVS Diodes Was ist eine TVS Diode? What is a TVS diode? I F V C V BR V WM
MehrCS 80 MAGNEO Zusatzset Sensorik add. set for safety sensor DORMA IRIS ON ACTIV8 ONE ON. Jupiter. Art Motion
WN 0 0 /0.. IS ACTIV E Presence Sensor Art Motion Nutzen Sie die beiliegende Bohrschablone des Herstellers. = = = = Please use the enclosed drill template provided by the manufacturer. oben top side unten
MehrPK-Serie MONOVOLT. AC/DC-Netzteile
PK-Serie: MONOVOLT AC/DC-Netzteile 30 bis 240 Watt primärgetaktete AC/DC-Einschubnetzteile mit einer in 3HE Eurokassetten für den Einsatz in 19"-Baugruppenträgern nach DIN41494 Kompakter Aufbau in stabiler
MehrHazards and measures against hazards by implementation of safe pneumatic circuits
Application of EN ISO 13849-1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free
MehrProduktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.
Produktdatenblatt Artikel Nr.: 341107 Wandaufbauleuchte, Alpha II, Weiß, 220-240V AC/50-60Hz, 100,00 W Technische Daten Charakteristik Material Farbe Weiß Optik im Lieferumfang Elektrische Daten Leistung
MehrBetriebsanleitung. Finhol Natural Tube Series - Booster. Technische Daten
Betriebsanleitung Natural Tube Series - Booster Aluminium Druckguss Gehäuse Gewicht ca. 300 gr. Masse: 145 x 95 x 50 mm Regler: Level Fussschalter Output/Input-Buchse 6,3 mm unsymmetrisch DC-Buchse: für
MehrTechnisches Datenblatt Technical Data Sheet. Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Familie 1 Channel Hall M18 Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Familie 1 Channel Hall M18 Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K (siehe Typen)
MehrDC-Stromquellen Produktkatalog. DC Current Sources Product Catalogue
DC-Stromquellen Produktkatalog DC Current Sources Product Catalogue 2014 Symbolerläuterungen für Features und Spannungsregelung mit einstellbarer Spannung Stromregelung mit einstellbarem Strom Leistungsregelung
MehrSensors Monitoring Systems
Sensors Monitoring Systems Dr.E.Horn GmbH Im Vogelsang 1 71101 Schönaich Germany Tel: +49 7031 6302-0 info@dr-horn.org DK 002629 Rev: 2 01.07.2015 1 /14 Absolut-Drehgeber Absolut-Encoder EGD50.5X und EGD50.7X
MehrEin- und Ausgangsspannung 220-240V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN 60601-1
Produktinformationen Powervar ABCE800-22IEC USV POWERVAR Unterbrechungsfreier Strommanager Der neue Security One USM oder unterbrechungsfreier Strommanager, hat viele neue Funktionen zu bieten. Sie können
MehrInduktive Näherungsschalter
www.ietz-sensortechnik.de support@ietz-sensortechnik.de Phone: +49(0)6252 94299-0 atenblatt INS-HL-01 Hochleistungsprogramm www.ietz-sensortechnik.de support@ietz-sensortechnik.de Phone: +49(0)6252 94299-0
MehrFundamentals of Electrical Engineering 1 Grundlagen der Elektrotechnik 1
Fundamentals of Electrical Engineering 1 Grundlagen der Elektrotechnik 1 Chapter: Operational Amplifiers / Operationsverstärker Michael E. Auer Source of figures: Alexander/Sadiku: Fundamentals of Electric
MehrMU-307 A SAFETY INSTRUCTIONS SICHERHEITSHINWEISE FEATURES MERKMALE
SAFETY INSTRUCTIONS Read all safety instruction before operating the amplifiers. 1. Install equipment as follow condition: - Install at flat place, not bending curved. - Do not install near the water and
MehrAR
OEM STEP-DOWN LED TREIBER 30W OEM STEP-DOWN LED DRIVER 30W BESCHREIBUNG DESCRIPTION Der ist ein einkanaliger Step-Down LED- Treiber zum sicheren und flexiblen Betrieb von Hochleistungs LED und LED Modulen
Mehr1 Allgemeine Information
1 Allgemeine Information ACHTUNG! Der Betriebsdruck der Klasse 867 ist 6 bar. Sollte der Druck Ihrer Versorgungsleitung höher als 6 bar sein, muss der Druck an der Versorgungseinheit der Nähmaschine auf
MehrOperation Guide AFB 60. Zeiss - Str. 1 D-78083 Dauchingen
Operation Guide AFB 60 Zeiss - Str. 1 D-78083 Dauchingen PCB automation systems AFB 30/60/90 Die flexiblen Puffer der Baureihe AFB werden zwischen zwei Produktionslinien eingesetzt, um unterschiedliche
MehrDC-Hutschienennetzgeräte Produktkatalog. DIN Rail DC Power Supplies Product Catalogue
DC-Hutschienennetzgeräte Produktkatalog DIN Rail DC Power Supplies Product Catalogue 2014 Symbolerläuterungen für Features und Optionen Spannungsregelung mit einstellbarer Spannung Stromregelung mit einstellbarem
MehrCAN-Bus RPM adapter. User Manual Anwender-Beschreibung
CAN-Bus RPM adapter COT02 User Manual Anwender-Beschreibung Stand: 12.02.03 GRABAU Computertechnik GmbH Elsener Str. 30 33102 Paderborn Tel: +49 5251 1367-0 Fax: +49 5251 1367-30 Email: info@grabau.de
MehrAsynchronous Generators
Asynchronous Generators Source: ABB 1/21 2. Asynchronous Generators 1. Induction generator with squirrel cage rotor 2. Induction generator with woed rotor Source: electricaleasy.com 2/21 2.1. Induction
MehrVARIOFACE Systemverkabelung
VARIOFACE Systemverkabelung Systemkabel und Übergabemodule für Yokogawa ProSafe-RS INTERFACE Phoenix Contact Dezember 12 Beinhaltet Crossliste......2 Übergabemodule.. 3 VARIOFACE System Cabling System
MehrSoftwareupdate-Anleitung // Porty L 600 / Porty L 1200
Softwareupdate-Anleitung // Porty L 600 / Porty L 1200 1 Softwareupdate-Anleitung // Porty L 600 / Porty L 1200 HENSEL-VISIT GmbH & Co. KG Robert-Bunsen-Str. 3 D-97076 Würzburg-Lengfeld GERMANY Tel./Phone:
MehrLED Konverter: Anschlussschemata LED converter: connection diagrams
LED Konverter: Anschlussschemata LED converter: connection diagrams TCI DC MAXI JOLLY DALI 48V DC, 48W (Konstantspannungsversorgung), dimmbar via Taster (Push) / 1-10V / DALI 6Z 48 10 00 Sicherheitshinweise
MehrAufgabenstellung Wie können zwei PCs an einer DCF77- oder GPS-Funkuhr betrieben werden?
SICLOCK Application Note AN-0006 Titel Y Kabel Aufgabenstellung Wie können zwei PCs an einer DCF77- oder GPS-Funkuhr betrieben werden? Schlüsselwörter SICLOCK DCFRS, WinGPS, GPS1000, DCF77-Empfangsdienst
MehrInductive proximity switch
3RG4070-0CD00-PF NO and NC / Schließer und Öffner 3RG4070-3CD00-PF NO and NC / Schließer und Offner 3RG4070-7CD0-PF NO and NC Schließer und Öffner 3RG4070-7CD0-PF NO and NC Schließer und Öffner Cable /
MehrServiceinformation Nr. 05/10
Serviceinformation Nr. 05/10 vom: 05.08.2010 von: GRC 1. Strömungswächter für Grundwasseranlagen Ab sofort können anstelle der Seikom Strömungswächter GF Schwebekörper Durchflussmesser mit Reed Kontakt
MehrSignal Processing LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen
LWL-Sender/Empfänger mit Outdoor-Box für die störsichere Übertragung von Rechtecksignalen LWL Sender/Empfänger mit Outdoor-Box Merkmale LWL-SBR, Übertragungsweiten bis zu 1500 m Wandlung üblicher Rechtecksignale
MehrINDEX. 3. Package Contents Connection and Operation...4
3 - P O R T H D M I S w i t c h V i s i o n 3 3 2 7 0 3 INDEX 1. I n t r o d u c t i o n... 2 2. S p e c i f i c a t i o n s... 3 3. Package Contents...3 4. P a n e l D e s c r i p t i o n s.. 4 5. Connection
MehrM12 Verteilerinsel / M12 Splitter box
Serie / Series VER 4-1 Technische Daten Technical data Norm Kabel ohne mit Standard Cable without with Polzahl Kontaktanforderung IEC 947-5-2 4/5 No. of contacts Contact configuration IEC 947-5-2 4/5 Verschmutzungsgrad
MehrVDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung
Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle
MehrServiceinformation Nr. 02/11
Serviceinformation Nr. 02/11 vom: 06.10.2011 von: BAM 1. Software Navigator und Release Notes Auf unserer Homepage unter www.idm-energie.at/de/navigator-software.html steht ab sofort eine neue Version
MehrNetzgerät compact Power Supply Unit compact 9.3389.10.010
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Bedienungsanleitung Instruction for use 021529/02/07 Netzgerät compact Power Supply Unit compact 9.3389.10.010 ADOLF THIES
MehrAU-D4. Analogue to Digital Audio Converter OPERATION MANUAL
AU-D4 Analogue to Digital Audio Converter OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 2 4.1 Front Panel Diagram 2 4.2 Rear
Mehrdiameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrAufgabenstellung Mit welchen SICLOCK Produkten kann ich einen PC Zeitsynchronisieren?
SICLOCK Application Note AN-0005 Titel Synchronisation von PCs mit SICLOCK Aufgabenstellung Mit welchen SICLOCK Produkten kann ich einen PC Zeitsynchronisieren? Schlüsselwörter SICLOCK DCFRS, WinGPS, GPS1000,
MehrSystem platforms 03. Komfortlösungen CPCI, VME, VPX. Comfort solutions CPCI, VME, VPX
System platforms 03 Komfortlösungen CPCI, VME, VPX Comfort solutions CPCI, VME, VPX Inhalt Contents Einführung 4 Systemplattformen PXI 4 HE, 63 TE 6 CompactPCI CPCI 3 HE, 30 TE 7 CPCI 3,5 HE, 42 TE 8
MehrI-Energieversorgung I-Power Supply
F Seite 1 page 1 1) Pneumatisch a. Stellantriebe mit Membrane finden ihren Einsatz da, wo kleine Stellkräfte ausreichen. Der pneumatische Stellantrieb ist direkt in Kompaktbauweise mit dem Stellventil
MehrGTP - Permanent Elektro Haftmagnet Datenblätter. GTP - Permanent electro magnet Datasheets
GTP - Datenblätter GTP - Datasheets GTP GTP Übersicht overview Übersicht / Overview Typ Type Dimensionen Dimensions [mm] F Haft F Holding [N] GTP-20 Ø20 x 22 70 GTP-30 Ø30 x 32 130 GTP-34 Ø34 x 39.6 260
MehrWestfalia Bedienungsanleitung. Nr
Bedienungsanleitung Nr. 107375 Bedienungsanleitung Satelliten Finder RL-TC-0101 Artikel Nr. 54 25 97 Instruction Manual Satellite Finder RL-TC-0101 Article No. 54 25 97 Benutzung Funktionsumfang Regelbare
MehrInstallation Zellprotektor
Installation Betrifft nur SunWare Solarmodule mit dreiadrigem Anschlusskabel! Version 2012!Wichtige Hinweise! Bevor Sie Ihr Solarmodul in Betrieb nehmen dürfen, muss zunächst 3adriges Anschlusskabel der
MehrLieferumfang / unit as delivered Best. Nr. / Order Code 1 HQI - Projektor AP 2 HQI -projector AP 2
PANI Projektoren lösen weltweit schwierigste Projektionsaufgaben. Der AP2 ist ein Spezialprojektor, der für den Dauerbetrieb bei Architekturprojektionen durch seine lange Lebensdauer der HQI-Lampe bestens
MehrParameter-Updatesoftware PF-12 Plus
Parameter-Updatesoftware PF-12 Plus Mai / May 2015 Inhalt 1. Durchführung des Parameter-Updates... 2 2. Kontakt... 6 Content 1. Performance of the parameter-update... 4 2. Contact... 6 1. Durchführung
MehrInstallation Instructions
EN DE Installation Instructions WLAN Installation Kit, 300 Mbps, 5 GHz, 16 dbi AK-4 Wireless Kit Scope of delivery Junction box AK-4 (1x) 1 Connection board AK-4 CB with 12VDC power supply unit (1x) 2
Mehrhigh potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren
Hochpotenzial - Hochspannungs - Trenntransformatoren pri - sec und einer Leistung von 1 VA bis 3000 VA Isoliertrafo, Isolationstransformator Einsatzmöglichkeiten Hochspannungstrenntransformatoren werden
Mehra new line of steam sterilizers
a new line of steam sterilizers ticheeasy to use and high consumption savings multifunction display controlled by micro-processor double and patented motor-operated closure stainless steel chamber without
MehrSensorView 890 HSD
SensorView 890 HSD 0290.005 SensorView 890 Übersicht Der SensorView 890 ermöglicht mit einem IP-65 Touchscreen Monitor die Konfiguration und Überwachung von einem oder mehreren Checkern der 4G Serie. SensorView
MehrVDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung
Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Einbauteil für IT Geräte Component for IT equipment Typ(en)
MehrTechnical Specification. Technische Spezifikation
Technical Technische Technical Schurter s range of "Audio, DC and DIN Connectors" offers a cost effective solution for a wide range of applications. Technische Schurter s Sortiment an Audio, DC und DIN
MehrUNIGATE CL Konfiguration mit WINGATE
UNIGATE CL Konfiguration mit WINGATE - UNIGATE CL Configuration via WINGATE Art.-Nr.: V3928 Deutschmann Automation GmbH & Co. KG Carl-Zeiss-Str. 8 D-65520 Bad Camberg Phone: +49-(0)6434-9433-0 Hotline:
MehrInterconnection Technology
Interconnection Technology Register: 23 Date: 25.05.99 Measuring leads from Hirschmann Following measuring leads are replaced by the next generation. Additionally connectors and sockets in the same design
MehrUNIVERSAL DMX-512 INTERFACE
Operation Manual Bedienungsanleitung UNIVERSAL DMX-5 INTERFACE Order Code: Bestellnummer: 505 505 VERSION 0/06 Universal DMX-5 Interface Version 0 / 006 INHALTSVERZEICHNIS CONTENT page /Seite ) Application
MehrMotorenreihe Einphasen Wechselstrom
Einphasen Wechselstrommotorensingle phase motors enreihe Einphasen Wechselstrom line single-phase Eckdaten Key data n s Gehäusematerial Frame material Number of poles Leistung Output 63 bis 100 63 to 100
MehrDatenblatt / Data sheet
Elektrische Kenndaten Eigenschaften / Electrical properties Höchstzulässige Werte / Maximum rated values Periodische Spitzensperrspannung repetitive peak reverse voltages Elektrische Eigenschaften Thermische
MehrDATENBLATT / FACT SHEET
DATENBLATT / FACT SHEET ART.-NR: SQUEEZE 3 PENDELLEUCHTE / SUSPENDED LUMINAIRE LED.next höheneinstellbare Pendelleuchte für den Home- und Loungebereich. Einzeln oder aber auch in Gruppen anwendbar. Lichtaustritt
MehrTechnisches Datenblatt Technical Data Sheet. Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Messing Familie 1 Channel Hall M18 Brass Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Messing Familie 1 Channel Hall M18 Brass Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67 Data
MehrGTP - Permanent Elektro Haftmagnet. GTP - Permanent Electro Magnet
GTP - GTP - GTP GTP Übersicht overview Baureihe Dimensionen FHalte GTP-20 Ø20 x 22 70 GTP-30 Ø30 x 32 130 GTP-34 Ø34 x 39.6 260 GTP-60 Ø60 x 53.5 620 Type Dimensions Fholding GTP-20 Ø20 x 22 70 GTP-30
MehrCONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP
ANLEITUNGEN // INSTRUCTIONS CONTROLLER RECEIVER REPEATER PAIRING SLIM CLIP BEDIENUNGSANLEITUNG // INSTRUCTION MANUAL MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION MONTAGEANLEITUNG // ASSEMBLY INSTRUCTION KOPPLUNG
Mehr4.2. Ausgangserweiterungseinheiten Output expansion units Unités d extension de sorties
. Ausgangserweiterungseinheiten s Unités d extension de sorties safety V 0 V 0 RE Ausgangserweiterungseinheit,,, 0 0 0 Material PA/PC material PA/PC matériau PA/PC 0 0 0 Optional mit Doppelklemmen 0, -,
MehrLWL Transceiver 9 x 1 SIP 650nm
LWL Transceiver 9 x 1 SIP 650nm Bild/Pic. 1 1 Allgemeine Beschreibung Der 9 x 1 Transceiver ist speziell geeignet für Anwendungen mit dem 1mm Standard- Kunststofflichtwellenleiter. Bestückt mit einer schnellen
MehrBedienungsanleitung Netzwerkkabeltester ST-45 v2
Bedienungsanleitung Netzwerkkabeltester ST-45 v2 Einführung Geehrter Kunde, wir möchten Ihnen zum Erwerb Ihres neuen Kabeltesters gratulieren! Mit dieser Wahl haben Sie sich für ein Produkt entschieden,
MehrLeister SYSTEM SINGLE PATCH MODULE SPM 01
D GB Leister SYSTEM SINGLE PATCH MODULE SPM 01 Leister Process Technologies Galileo-Strasse 10 CH-05 Kaegiswil/Switzerland Tel. +41-41 4 4 Fax +41-41 4 1 www.leister.com sales@leister.com Einbauanleitung
Mehrmiditech 4merge 4-fach MIDI Merger mit :
miditech 4merge 4-fach MIDI Merger mit : 4 x MIDI Input Port, 4 LEDs für MIDI In Signale 1 x MIDI Output Port MIDI USB Port, auch für USB Power Adapter Power LED und LOGO LEDs Hochwertiges Aluminium Gehäuse
MehrVerstärker / Amplifiers. Linien- und Verteilverstärker / Trunk and distribution amplifier
Konzeption der Linien- und Verteilverstärker der LV-Verstärkerserie Concept of the trunk and distribution amplifiers of the LV amplifier series 1. Eingangsentzerrer vorwärts (Auslieferungszustand: 0 db-steckdämpfer)
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung
MehrLeistungsdichte 400 W/l Leistung bis zu 1500 W. digital oder analog steuerbar 19 oder Wandmontage. 26 TE / Wandschrank / Hutschiene
Netzgerät 1500 Watt Spannungen 150 bis 400 VDC Leistungsdichte 400 W/l Leistung bis zu 1500 W digital oder analog steuerbar 19 oder Wandmontage kundenspezifisch anpassbar Kurzbeschreibung Das Netzgerät
Mehr0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50
Mehr