FlowBox-Control-HC (FBC-HC)

Ähnliche Dokumente
VERTEILERSYSTEMTECHNIK

FlowBox HK / HKF / HKM 8180

TECHNICAL DATA SHEET Member of Uponor Group

Attenuator and Distribution System Zehnder ComfoWell 220

DGR CE SICHERHEITSVENTILE PED CE SAFETY VALVES

SWC PENDELROLLENLAGER SWC SPHERICAL ROLLER BEARINGS

Zehnder ComfoWell 220

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series

Zehnder ComfoWell 320

Zehnder CLD. Housing for walls, floors and ceilings

Attenuator and Distribution System Zehnder ComfoWell 320

Specification. DESIGN Swing check valves for return fl ow prevention in piping systems to be mounted directly between fl anges acc. to DIN.

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

Connecting bend 90 connecting bend parts that serve as a connection between the hydraulic separator and the compact manifold.

Electrical tests on Bosch unit injectors

3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled

VGX/2 VGX. Kreiselpumpen

direktgesteuert direct acting

OEM Katalog. B. Verteilersysteme für Flächenheizung/-kühlung Manifold systems for radiant panel heating/cooling

Snap-in switch for switches PSE, MSM and MCS 30

Specification. OPERATION Rotation of the handwheel.

Daten Visualisierung - VS -

Montageanleitung. Leben voller Energie. Energiesysteme Mischergruppe Ex DN 25 WNR: _003. HKM FlowBox-WP. mit Yonos Para 25/7; Kvs6,3

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

ERHARD is a company of. Datasheet ERHARD ECR check valve

Westenberg Wind Tunnels

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

diameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316

ÜBERSTRÖMVENTILE OVERFLOW VALVES. Type 618 T / Type 619 E for liquids, steam and gaseous media

Herzlich Willkommen Welcome

SICHERHEITSVENTILE OHNE BAUTEILPRÜFUNG SAFETY VALVES WITHOUT TEST CERTIFICATE. Type 602 E / Type 601 T for liquids, gaseous media and steam

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50

Roth Regelstation RKR 3 H/K

A P max. 16bar P R max. 64bar R P max. 16bar

2/2-way solenoid valve - Type 218

Tube Analyzer LogViewer 2.3

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

mobilcom-debitel SmartHome Schnell-Start-Anleitung Quick Start Guide

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 286 Type 286. fremdgesteuert externally controlled

Overview thermostat/ temperature controller

direktgesteuert direct acting

VEKA. Air handling units. Lüftungsgeräte. Air handling units

direktgesteuert direct acting

Hinweisblatt. Für den Einsatz des MAX! Heizungssteuerungssystems haben Sie zwei Alternativen: Die MAX! Einzelraumlösung und die MAX! Hauslösung.

Baureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32

Einbau- und Montageanleitung Wanddurchführungs-Set Seite 3-4 Assembly instructions and mounting guide Wall pipe set Page 5-6

2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting

MUB Technische Änderungen vorbehalten Seite 1

Test Report. Test of resitance to inertia effects of Zirkona Backwall. Sled Test (Frontal Impact) 20 g / 30 ms

2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148

Walter Buchmayr Ges.m.b.H.

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Flow through sight glasses Nr. 440/450

Baureihe 280 / 281 / 282 Type 280 / 281 / 282

Kompakt doppelt exzentrische Kugelhähne Compact double offset Ball Valves

BK 250 / BK 370. Umweltfreundliche Solarwärme für Ihren Pool. Mit einer BADU BK Schwimmbad-Absorber-Anlage verlängern Sie Ihre Badesaison.

servogesteuert pilot operated

Durchflussmesser Flow meter. Typen / Types:

Datenblatt. P-series PDU 2.5/4/4AN

Electrical testing of Bosch common rail piezo injectors

Materialdruckregler Material pressure regulator

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T

Specification. DESIGN Body consists of one part MR3400xx approval acc. to 1935/2004/EC. CONNECTION Female thread 1 /4" up to 4" acc.

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

tubra - PGM / PGR S Das universelle Heizkreissystem The universal system for heating circuits

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

Hazards and measures against hazards by implementation of safe pneumatic circuits

Baureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator

Flowbox HK20/HKM20 VB20. Pumpen-/Pumpenmischergruppe DN20. Verteilerbalken DN20. Technisches Datenblatt. WattsWater.de

Manual Kleinverteiler - 80/60, 125 mm Stutzenabstand Small manifold - 80/60, 125 mm nozzle spacing Stand 06/2015

Umschaltventile Magnete

Kugelhähne Ball-valves

Technik conversion. information. Deutsch English

Mechanisch betätigte Ventile Typ 46 NW 2 3/2-Wege Sitzventile Direktgesteuert

Attenuator and Distribution System Zehnder ComfoWell 520

DIGICONTROL- Gerätedatenblatt R-RTS-T 0,14-2,5mm², über Schraubklemmen auf Platine

_02 Eastern Europe,02/2011. Wall-hung boilers eloblock Elektro-Wandheizgeräte eloblock VE 6 VE 9 VE 12 VE 14 VE 18 VE 21 VE 24 VE 28

OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2.

SWC SPANNLAGER UND GEHÄUSE SWC RADIAL INSERT BALL BEARINGS AND HOUSING

UFPR. Extraction table with fan. Absaugtisch mit Ventilator Typ

LOVATO Smart Energy Solutions Ungemischte gruppe D!"#$%&'(!%&) * Vordere Isolierung +",(%&!(-'./%!,(

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015

Technische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011

Specification. FACE TO FACE LENGTH Acc. to EN row 20.

Montageanleitung / Assembly instruction

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

Bauform A Bauform B * Bauform A Bauform C. Horizontal Horizontal Vertikal mit Hängefeder Vertikal mit Einlegering

INOVA NH/ND. Heizungsumwälzpumpen

EINBAUHINWEISE INSTALLATION INSTRUCTIONS

Umschaltventile Magnet

direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow

Transkript:

Heiz-/ Kühlkreis Regelstation / Heating and cooling circuit control unit FlowBox-Control-HC (FBC-HC) Vorteile Montagefertige, kompakte Regelstation Witterungsgeführte Regelung der Vorlauftemperatur Raumtemperatur- / Feuchteregler aufschaltbar Integrierter Klimaregler ClimaticControl-HC Bis 0 kw Wärmeleistungsbedarf Einfachster bauseitiger Anschluss durch werkseitig vormontierte und verkabelte Komponenten Ausnahmslos flachdichtende Verbindungen Wärmedämmschale aus EPP Advantages Ready-to-mount compact unit Variable water temperature control in conjunction with the outside temperature Can be used with a room thermostat / hygrostat With climate controller ClimaticControl-HC For heat output requirements up to 0 kw Easy installation and start-up due to premounted and pre-wired components ex-works All connections with flat seals throughout Heat insulation box made of EPP

Wärmedämmschale geschlossen / Heat insulation closed Wärmedämmschale offen / Heat insulation open Anwendung Die Regelstation FBC-HC wird für die lastabhängige Regelung der Vorlauftemperatur von wasserführenden Heiz- oder Kühlsystemen, insbesondere von Flächenheizungen/-kühlungen eingesetzt. Die Vorlauftemperatur wird in Abhängigkeit der Außentemperatur anhand einer wählbaren Heiz-/Kühlkurve geregelt. Mit dem Klimaregler CC-HC kann die Anlage entweder ausschließlich im Heizbetrieb, ausschließlich im Kühlbetrieb oder im kombinierten Betrieb Heizen/Kühlen geführt werden. Die Umschaltung HEIZEN/KÜHLEN kann manuell oder über ein externes Umschaltsignal (z.b. von einer reversiblen Wärmepumpe etc.) erfolgen. Mit der FBC-HC kann eine Wasser Flächenheizung/-kühlung betrieben werden, die auf die individuellen Erfordernisse einer Wohnung oder von einzelnen Wohnoder Geschäftsräumen eingestellt ist. Der integrierte Klimaregler CC-HC besitzt eine 7-Tage-Programmierung mit 9 werkseitig fest integrierten Standardprogrammen sowie frei definierbare Benutzerprogramme. Optional kann auf den Klimaregler ein Raumthermostat, wahlweise mit integriertem Feuchtefühler, aufgeschaltet werden. Passende Raumthermostate sind als kabelbasierte Versionen oder als Funk-Thermostate im Zubehör verfügbar. Dadurch wird der Betrieb der Flächenheizung/-kühlung auf das Nutzungsverhalten eines Referenzraums optimiert. Die FBC-HC ist für den Einsatz in trockenen Räumen, im Wohn- sowie im Gewerbebereich vorgesehen. Üblicherweise wird diese im Heizungsraum installiert. Nicht bestimmungsgemäßer Einsatz ist anhand der geltenden Vorschriften vor Inbetriebnahme zu prüfen. Regler / Control MILUX Hygrostat Application The hydraulic control unit FBC-HC is used for variable flow temperature control in water heating and cooling systems particular in floor and panel heating/cooling systems. The flow temperature is controlled dependent on the outside temperature using a selectable heating/cooling curve. The ClimaticControl-HC enables running the system either in heating mode only, in cooling mode only or in combined mode heating and cooling. The commutation heating-cooling can be done manually or using an external signal (e.g. from a reversible heat pump etc.) The FBC-HC can operate a water heating/cooling system which is set to suit the individual requirements of an apartment or individual domestic or business areas. The integrated CC-HC climate controller has a 7 day program with 9 ex-works fixed integrated standard programs as well as programs which can be set as required by the user. A room temperature controller optionally with humidity sensor can be connected to the CC-HC climate controller. Suitable cable based or radio-controlled programmable room thermostats are available as accessories. These enable radiant panel heating/cooling system operation to be optimised based on the usage pattern of a reference room. The FBC-HC is intended for use in dry areas in either domestic or business premises. It is normally installed in the boiler room Check in the relevant regulations for improper use before commissioning. ANTENNA

Aufbau / Funktion Montagefertige, kompakte und witterungsgeführte Regelstation für Flächenheizung/-kühlung. Pumpe, - Wegemischer mit Stellmotor, Regler sowie Vor- und Rücklauftemperaturfühler werkseitig verkabelt. Außentemperaturfühler. EPP-Wärmedämmschale. Wandhalter. Integrierter Klimaregler CC-HC mit Wochenprogramm. Eingang für Raumtemperatur- und Feuchtefühler als Funk-Regler. Umschaltsignal Heizen/Kühlen. Programm zum Estrich Funktions- und Belegreifheizen. Die Regelstation FBC-HC besteht aus sorgfältig aufeinander abgestimmten Einzelkomponenten die alle flachdichtend miteinander verbunden sind. Die Regelstation ist wahlweise mit Standard Umwälzpumpen ( stufig) oder mit drehzahlgeregelten Pumpen (E-Pumpe) oder Hocheffizienzpumpen verfügbar. Der Dreiwegemischer aus Messing ist mit Kvs-Werten von 2,5 bis 8,0 erhältlich. Der vom Klimaregler anhand der aktuellen Außentemperatur und Heiz-/Kühlkurve berechnete Sollwert der Vorlauftemperatur wird durch den Vorlauf Fühler stetig überwacht. Bei Temperaturabweichungen veranlasst der Regler über den Stellantrieb ein Öffnen oder Schließen des Mischventils bzw. bei Erreichen des Sollwerts die Ventilstellung zu halten. Design / Mode of operation Ready-to-mount compact unit suited for variable water temperature control in conjunction with the outside temperature for floor heating/cooling systems. Pump, -way-mixing valve with valve drive and climate controller CC-HC with water in and out sensor pre-mounted and wired ex-works. Outside temperature sensor. EPP heat insulation box. Wall mounting brackets. Integrated climate controller CC-HC with 7-day-program. Input RF-thermostat with humidity sensor. Heating/cooling commutation. Screed preheating and dehydration program. The control unit FBC-HC is made up of precision-matched components with flat-seal connections. The unit can be delivered with standard ( speed) pump as well as with variable speed controlled pumps or high-efficiency pumps. The mixing valves are available with Kvs values from 2,5 to 8,0. The desired value of the supply temperature calculated by the climate controller on the basis of the current outside temperature and a heating/cooling curve is constantly monitored by the temperature sensor in the heating supply. Any temperature deviations from the target value are balanced out immediately by opening or closing the mixing valve. Einsatz in der Praxis In Verbindung mit einem Verteilerbalken können mehrere Regelstationen Alternativ auch ohne Regler oder ohne -Wegemischer installiert werden. Die Abmessungen sind sehr kompakt, so dass ein Einbau selbst bei beengten Platzverhältnissen z. B. bei Dachheizzentralen oder in Nischen möglich ist. Installation Together with a heating circuit distributor /header more than one heating circuit control unit can be installed. Such units are also available without controller or without mixing valves. The compact dimensions of the unit allow installations in areas with narrow space. Sortimentsübersicht / Product range Type Pumpe / Pump EuP Art.-Nr. / Art.-code ready 1) Kvs 2,5 Kvs,0 Kvs 6, Kvs 8,0 FBC-HC Wilo Star-RS 25/- FBC-HC Wilo Star-RS 25/6- FBC-HC Wilo Stratos PICO OEM 25/1-6 x FBC-HC Grundfos UPS 25-0 FBC-HC Grundfos UPS 25-60 FBC-HC Grundfos ALPHA2 25-60 x 1) Pumpe erfüllt Anforderungen der Öko-Design Richtlinie 2005/2/EG Pump fulfils requirements of ecodesign directive 2005/2/EC

Technische Daten Technical Data Max. Betriebstemperatur: Max. operating temperature: 90 C Min. Betriebstemperatur: Min. operating temperature: 2 C Max. zulässiger Betriebsdruck: Max. operating pressure: 6 bar Max Prüfdruck : Max. test pressure: (2 h, < 0 C) 10 bar Werkstoffe Materials Armaturen: Messing Ms58; CW61N Housing: Brass Ms58; CW61N Rohre: Präzisions-Stahlrohr EN 1005- Pipes: Precision steel pipe EN 1005- Kunststoffe: schlagzäh und temperaturfest Plastic: Impact- and temperature resistant Dichtungen: EPDM-Elastomere bzw. AFM Gaskets: EPDM-Elastomers or AFM Halter: verzinkter Stahl Brackets: Steel, galvanised Verfügbare Pumpen Förderhöhen Die Verfügbare Förderhöhe bei Einsatz anderer Mischer Kvs-Werte teilen wir auf Anfrage gerne mit. Available pump heads All data s for other mixing valve Kvs values are available on request only. Verfügbare Förderhöhe / Available pump head FBC-H, FBC-HC; Mischer Kvs 6, Förderhöhe Pumpe / pump head [m] 7,0 6,0 5,0,0,0 2,0 1,0 2 5 6 Maximal-Kennlinien [Pumpe Δp-c (constant)] 1 1 Wilo RS 25/- 2 Wilo RS 25/6- Grundfos UPS 25-0 Grundfos UPS 25-60 5 Wilo PICO OEM 25/1-6 6 Grundfos ALPHA2 25-60 0,0 0 0,2 0, 0,6 0,8 1 1,2 1, 1,6 1,8 2 Technische Änderungen vorbehalten Subject to technical modifications Volumenstrom / volume flow [m³/h]

Regler Display / Control display Abmessungen / Dimensions 50 Wand / Wall 1 55 2 5 6 7 8 9 10 11 12 1 6 250 125 08 215 1 IG Details Pos. 6 a b c 1 IG 1 Symbolleiste Betriebsarten Operating modes 2 Tastensperre aktiv Keyboard is locked Service-Menü Service Installation Menu Handbetrieb / Programm-Override aktiv (Anzeige der Temperaturdifferenz) Manual operation / program override active (display of temperature offset) 5 a) Anzeige Temperatur ( C / F) a) display temperature ( C / F) b) Anzeige Uhrzeit (12 h / 2 h) 6 Symbol für Temperaturanzeige a) Vorlauftemperatur Wasser b) Außentemperatur c) Raumtemperatur (falls Raumthermostat aufgelegt) 7 Grafische Anzeige Programmfolge Komforttemperatur Absenktemperatur b) display time (12 h / 2 h) Type of temperature displayed a) Water temperature b) Outside temperature c) Room temperature (if RF room thermostat connected) Program graphic of the current day Comfort temperature Reduced temperature 8 Umwälzpumpe in Betrieb Pump indicator 9 Betriebsweise Working mode Heizen / Kühlen / Luftentfeuchter aktiv Heating / Cooling / Humidity function 10 Wochentag (1 = Montag; 7 = Sonntag) Current day of the week (1 = Monday; 7 = Sunday) 11 Symbol bei Funk-Signal Übertragung (optional). RF reception indicator (optional). 12 a) Symbol Temperaturanzeige in C / F b) Symbol AM / PM bei Zeitanzeige 12 h a) Symbol temperature indication in C / F b) Symbol AM / PM if 12 h mode 1 a) Anzeige Temperatur ( C / F) b) Anzeige Uhrzeit (12 h / 2 h) a) Outside temperature ( C / F) b) Time (12 h / 2 h) 1 Funktionsanzeige Stellantrieb Stellantrieb öffnet Stellantrieb schließt Mixing valve activity indicator Valve actuator is opening Valve actuator is closing

Installations-Schema / Installation schematic 5 FH/K 12 15 7 6 1 11 10 2 20 V/AC 1 9 M 8 FBC-HC 1 17 16 M 1 Wärmeerzeuger Boiler 2 Umwälzpumpe Kessel-/Heizkörperkreis Circulation pump boiler / radiator circuit Vorlauf Kessel-/Heizkörperkreis Boiler / Radiator supply Rücklauf Kessel-/Heizkörperkreis Boiler / radiator return 5 Heizkörper Radiator 6 Vorlauf Flächenheizung FH Floor heating (FH) supply 7 Rücklauf Flächenheizung FH Floor heating (FH) return 8 -Wege-Mischer mit -Punkt-Antrieb -way mixing valve with -point-actuator 9 Umwälzpumpe FH Circulation pump for floor heating 10 Kugelhahn Shut-off valve 11 Temperaturfühler FH-Vorlauf Supply temperature sensor FH 12 Außentemperaturfühler Outside temperature sensor 1 Regler ClimaticControl ClimaticControl 1 Temperaturbegrenzer (optional) Temperature limiter (option) 15 Raumthermostat (optional) Room thermostat (option) 16 Kälteerzeuger Chiller 17 Umschaltventil Heizen/Kühlen Zone valve heating/cooling FH/K = Flächenheizung/-kühlung FH/K = Floor heating / cooling Weitere Installationsschemen befinden sich in der Montage- und Betriebsanleitung der Regelstation bzw. des Reglers Further installation schematics are available in the manuals of the control unit or the control Re-order no. PDB_FBC-HC_DE-EN_2010-10-19 Die Fotos, Abbildungen und Beschreibungen dieser Broschüre, dienen lediglich zur Information. Watts Industries behält sich das Recht vor, technische und konstruktive Änderungen an seinen Produkten ohne vorherige Nachricht durchzuführen. The photos, illustrations and descriptions contained in this brochure are solely intended for information. Watts Industries reserves the right to make technical and design modifications to its products without prior notice. Watts Industries Deutschland GmbH Division OEM Godramsteiner Hauptstraße 167 76829 Landau Germany Tel. +9 61 9656-0 Fax +9 61 9656-0 E-Mail: info@wattsindustries.de