Präzisionstechnik fürs Leben. TRIGO TRIGOdis NARKOSEGERÄT ANAESTHESIA UNIT

Ähnliche Dokumente
Präzisionstechnik fürs Leben. XENON ready TANGENS 2C ANÄSTHESIESTATION ANAESTHESIA UNIT

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

OIL-FREE MEDICAL compressors

Hochspannungsmessgerät HV 3000 Wechsel- / Gleich- / Impulsspannung

a new line of steam sterilizers

Lufft UMB Sensor Overview

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Zehnder ComfoWell 220

Electrical tests on Bosch unit injectors

Product overview 2012

GERÄTE - UNITS. tk 754-r100 TEKNO LIGHT XA automatic tk 754-Xa100 Ersatzlampe Watt Helligkeitsregelung

Walter Buchmayr Ges.m.b.H.

Westenberg Wind Tunnels

Hazards and measures against hazards by implementation of safe pneumatic circuits

Cleanroom Fog Generators Volcano VP 12 + VP 18

Zehnder ComfoWell 320

Einweisung auf das Medizinprodukt: Teil 3: Beatmungsfunktionen. Detlev Krohne LRA

LVM92-EHP. Index. Elektrohydraulisches Frontladerventil. Produkteigenschaften. Spezifikation. Offenes System. Load Sensing. Hydraulische Eigenschaften

Technische Information Stand : 08 / 2016

technical documents for extraction and filter devices type series 1000

Zehnder CLD. Housing for walls, floors and ceilings

Attenuator and Distribution System Zehnder ComfoWell 220

TV- und Bildschirmhalterungen TV and monitor screen mounts

KNX Glassensor KNX Glass Touch Sensor

SEIFENBLASENMASCHINE H-8 BUBBLE MACHINE H-8 CODE Spezifikationen. Technical specifications

Technische Spezifikation

ABB i-bus EIB. EIB Power Supply Units

WIC1-TU Abfrageeinheit für das WIC1 Monitoring unit for WIC1 relays

INDEX. 3. Package Contents Connection and Operation...4

Tischbefettungsvorrichtung TBV, horizontal Tabletop greasing unit TBV, horizontal

ELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/

Tube Analyzer LogViewer 2.3

Overview thermostat/ temperature controller

Umschaltventile Magnete

DIGICONTROL- Gerätedatenblatt F-KCO2T1 2-Strahlverfahren, (nicht-dispersive Infrarot Technologie) NDIR

ASP-1750 HUB-POSITIONIEREINHEIT BETRIEBSDRUCK 4-8 BAR

Bedienungsanleitung / Manual : LED-Nixie

Control shut-off butterfly valves DN 50 DN 400 PN

Analog GSM-Gateway TRF

ZLM. J. Lasermessköpfe, Auswerteeinheiten, und Zubehör J. Laser measurement heads, evaluation units, adapters and accessories

+ + Darf es ein bisschen mehr sein? May it be a little more? Kompakt III. Der Klassiker The classic. + Ultra compact 87 x 54 x 26 mm

Präzisionstechnik fürs Leben. CΛLIBSO Family. Die neue Messgeräte-Generation The new generation of measuring devices

OPUS. Spannzylinder Clamping Cylinders

Daten Visualisierung - VS -

Umschaltventile Magnet

Technische Daten / Technisches Merkblatt (nach pren ) ECHOGRAPH 1016B (Best.-Nr )

VTQ OC-40 VTQ OC-40. VTQ Videotronik GmbH Grüne Straße Querfurt Phone Fax

[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...

ORION three-phase 2-250kVA

technical documents for extraction and filter devices type series 220

WAM 235 Analysemessgerät mit Loggerfunktion WAM 235 Analysis instrument with logger function

Datasheet. Page 1 of 7

MPC-460. Edition: Mobile Process Computer. Bemerkung/Remark: 1/6. Abmessungen/Dimensions [mm]:

Der Xpress ist ein drahtloser Lichtschalter und eine Fernbedienung

CAB 700, CAB 706, CAB 920

Attenuator and Distribution System Zehnder ComfoWell 320

3/2-Wege Coaxialventil 3/2-way coaxial valve. Baureihe 380 / 381 Type 380 / 381. fremdgesteuert externally controlled

KRUPP Drehantriebe / rotary drives

TECHNICAL DATA SHEET Member of Uponor Group

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL

rot red braun brown rot red RS-8 rot red braun brown R S V~

ZLM. Lasermessköpfe, Auswerteeinheiten, Anbausätze und Zubehör Laser measurement heads, evaluation units, adapter and accessory

Data-S EASY VERSTREUTE ÜBERWACHUNG DER NOTBELEUCHTUNG

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

Quality control and process tracking. From concept to acceptance.

List pumps. Table of contents. Si-61. Si-30. Si-63


EL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL

The future of snow. The silent hero of snow guns

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

SETUP TOOL. Bedienungsanleitung User s Manual

Datenblatt / Data sheet

Mechanisch betätigte Ventile Typ 46 NW 2 3/2-Wege Sitzventile Direktgesteuert

Digital Rockwell-Testing-Machine KB 150 R

Oxylog 1000 Notfall- und Transportbeatmung

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

Specification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control

Attenuator and Distribution System Zehnder ComfoWell 520

8.1 STEUERKOPF 8680 CONTROL TOP 8680

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

Gas Flow Sensor. Der nächste Schritt zu mehr Prozesssicherheit The next step to a more reliable process

Peter Kremeier, Christian Woll

Betriebsanleitung/ Operating instructions. EGA/PC-Interface-2 EGA/PC-Interface Anschlussbox 4-fach

Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC

+ + Mit Sicherheit auch mit Batterie. Safe, even with battery. Linear V NLE

Counterflow Heat Recovery Fan

UCON UCON Kurzanleitung Inbetriebnahme

AGM-Batterie Model: WT-SA12-12 (12V 12AH)

EMCO Installationsanleitung / Installation instructions

T C. uropean Technical Center for Engineering & Distribution GmbH. ETC-Distribution

INCLUDES: Fully assembled 4 wheels for mobile use Power cable

KRUPP Produktübersicht / Product Range

Bedienungsanleitung. User Manual

Transkript:

Präzisionstechnik fürs Leben. TRIGO TRIGOdis NARKOSEGERÄT ANAESTHESIA UNIT

the small and compact one now with 12 touchscreen Der kleine kompakte jetzt mit 12 Touchscreen Durch die Erweiterung der Produktpalette mit dem kleinen elektronischen Wand- Narkosegerät TRIGO komplettiert EKU seine Kompaktklasse von Anästhesiegeräten. Mit der Leistungsfähigkeit einer größeren mobilen Anästhesiestation findet der TRIGO als Wandgerät oder auch als mobile Variante seinen Platz in der Einleitung. By extending its product range with the small electronic wall-mounted anaesthesia unit TRIGO EKU completes its compact class of anaesthesia units. With the performance of a bigger mobile anaesthesia machine the TRIGO finds its place in the induction as wall mount device or as mobile version. 2

Auf den ersten Blick Mit einem größeren 12 TFT-LCD Touchscreen ermöglicht die TRIGOdis Variante zusätzlich zum hohen Bedienkomfort beste Ablesbarkeit aus weiterer Distanz. Ein solider kippund drehbarer Doppelhalter sorgt für eine optimale Platzierung des Zentralmonitors und Vitalmonitors. Komplett ausgestattet Neben dem elektronischen Gasmischer und dem Multimode-Anästhesie-Ventilator inklusive unterschiedlicher Ventilationsparameter können optional auch verschiedene Monitorfunktionen integriert werden (O 2, CO 2, Anästhesiegase, N 2O). Zur Komplettausstattung mit dem neuen optionalen Zubehör zählen unter anderem Infusionsstange, mehrfach Schublade, Doppelhalter für das Monitoring, seitliche Normschiene mit Sekretabsaugung und ein Halter für die Reservegasflasche. at first glance With a bigger 12 touchscreen the TRIGOdis version enables best readability from a distance in addition to high operating comfort. A solid tiltable and pivotable double holder provides optimal positioning of the central monitor and vital monitor. fully equipped Besides the electronic gas mixer and the Multimode-Anaesthesia-Ventilator including different ventilation parameters also various optional monitoring functions can be integrated (O 2, CO 2, anaesthetic agents, N 2O). The fully equipped TRIGOdis features new optional accessories such as infusion rod, multiple drawers, double holder for monitoring, lateral standard rail with secretion suction and a holder for spare cylinder. Mehr Freiheit Ob als Wandgerät mit der Einbautiefe eines Bücherregals ( Shelf Unit ) oder in Verbindung mit einem modernen Fahrgestell bietet der TRIGO mehr Bewegungsfreiheit im Einleitungsraum. more freedom Either as a wall mount device with the installation depth of a bookshelf ( shelf unit ) or in combination with a modern trolley the TRIGO offers more freedom of movement in the induction room. 3

Funktionen n 6,4 oder 12 Touchscreen TFT-LCD mit zentralem Drehknopf n Dialog-Bedienung am Bildschirm n Selbsttest und Kontrolle der einzelnen Komponenten im standby -Modus n Automatischer Dichtigkeitstest n Elektronische Überwachung der eingestellten Gasdosierung n Elektronische Druckgasversorgungsüberwachung mit Anzeige und Alarmfunktionen bei Druckunterschreitung n Kompensation von Versorgungsdruckschwankungen n Ermittlung der Systemcompliance n Dynamische Compliancekompensation n Großer Einstellbereich von 200 ml bis 11 Liter n Feinauflösung und Balkenanzeige erfolgt in 20 ml Schritten n Automatische Umschaltung der Skalierung bei größeren Flow-Werten n Automatische Frischgasfeindosierung für Low Flow Betrieb n Low-Pressure-Technik ab 2 bar Druck n Anzeige der Messwerte als Kurven und numerische Werte n Konfigurierbare Grundeinstellungen, spezifisch für jede Beatmungsform n Speicherung der Standard Voreinstellungen Functions n 6,4 or 12 colour touchscreen TFT-LCD with central rotary button n dialogue handling at the screen n self-test and control of the single components in standby mode n automatic leakage test n electronic control of the adjusted gas dosage n electronic supervision of the pressure gas supply with display and alarm function for lower deviation in pressure n compensation of variations in pressure supply n detection of the system compliance n dynamic compliance compensation n wide adjustment range from 200 ml to 11 litres n precise resolution and display of the scale in 20 ml steps n automatic scale switching for higher flow values n automatic fresh gas dosing for low flow operation n low-pressure-technology from 2 bar pressure n display of the measured values as curves and numeric values n configurable basic adjustments, specific for each ventilation mode n default parameters can be defined n integrated monitor for volume, pressure, O 2, anaesthetic agents, N 2O, CO 2 n electronic PEEP n for neonatal, paediatric and adult application n integrierter Monitor für Volumen, Druck, O 2, Anästhesiegase, N 2O, CO 2 n Elektronischer PEEP n Geeignet für Neugeborene, Kinder und Erwachsene n Auslesbarer Ereignisspeicher für Fehlerzustände und Serviceinformationen n Optimale optische und akustische Visualisierung der Alarme n Verdampferhalterung einfach für verschiedene Verdampfer (Halothan, Enfluran, Isofluran, Sevofluran, Desfluran) n Kompaktes Kreissystem, CO 2-Absorberkanister im Betrieb ohne Leckage auswechselbar n RS232 Schnittstelle zur Anbindung an elektronische Anästhesiedokumentation und Klinik IT-Netzwerk n error state and service information logging n best optic and acoustic visualising of the alarms n single holding for different vaporizers (Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane) n compact circle system, CO 2-absorber canister is exchangeable during operation without any leakage n RS232 interface for connection to electronic anaesthesia documentation and clinical IT-network 4

Sicherheitssystem n Elektronische O 2-Mangelerkennung n Elektronische N 2O-Blockade n Sauerstoff-Notdosierung bei Systemausfall (mind. 4 L/min O 2 Flow bei Komplettausfall) n Notdosierung bei Ausfall Gasversorgung: Ausfall AIR: 100% O 2, Ausfall N 2O: 100% O 2, Ausfall O 2: 100% AIR n Automatische Überprüfung bei jedem Einschalten auf korrekte Belegung der einzelnen Gasversorgungskanäle n Sicherung der Funktion bei Stromausfall durch eingebauten wiederaufladbaren Akku für mindestens 30 Minuten Security system n electronic O 2-deficiency detection n electronic N 2O-blockage n O 2-emergency dosage (min. 4 L/min O 2 flow in case of total failure) n emergency dosage for gas supply failure: failure AIR: 100% O 2, failure N 2O: 100% O 2, failure O 2: 100% AIR n automatic check for correct covering of the single gas supply channels every time the device is switched on n operation is guaranteed for at least 30 minutes at power supply failure by an internal rechargeable battery Beatmungsparameter n CMV (volumengeregelt) n PCV (druckgesteuert) n MAN./SPONT. (manuell, spontan), Spontanbeatmung mit Apnoe Überwachung n SIMV (synchronisierte intermittierende mandatorische Ventilation) n MMV (mandatorische Minuten Ventilation) n ASB (druckunterstützend) Ventilation parameters n CMV (volume controlled ventilation) n PCV (pressure controlled ventilation) n MAN./SPONT. (manual, spontaneous), spontaneous ventilation with apnea control n SIMV (synchronous intermittend mandatory ventilation) n MMV (mandatory minute ventilation) n ASB (pressure support ventilation) 5

Technische Daten trigo TRIGOdis Allgemeine Daten: Display farbig, TFT-LCD 6,4 oder 12 (TRIGOdis) Stromversorgung intern Akku 12V, 3,2 Ah (fest eingebaut) Stromversorgung extern 100 240V, 50/60Hz Leistungsaufnahme max. 80 VA Temperaturbereich 15 35 C Abmessungen 800x350x400 mm (L x T x H) Gewicht 33 kg Patiententeil: Typ Volumen Überschußventil Kreissystem: Volumen (ohne Schläuche) Volumen Absorber Berner Ventil bellows in bottle senkrecht 1,5 l Ansprechschwelle: 2 mbar ca. 2 l 750 ml 5 50 mbar, VOL, SP Fahrgestell: Abmessungen 610x620x1230 mm (L x T x H) Gewicht 32 kg (mit Monitorhalter) Ventilator: Ventilationsmodus CMV, PCV, SIMV (MMV und ASB in Vorbereitung) Tidalvolumen (CMV) 20 1500 ml (Flow: 3 160 l/min) Inspiratorischer Flow (PCV) 10 80 l/min Frequenz 3 100 1/min I:E-Verhältnis 2:1-1:4 (Ti 0,3 10 s) Inspirationspause 0 60% Ti PEEP OFF, 3 20 hpa Druckbegrenzung P MAX (PEEP +5) bis 80 hpa Flowtrigger (spontan Modus) 0,3 15 l/min : Tidalvolumen ± 10% (Ausgang bellows in bottle ) P MAX ± 2 hpa oder 5% rel. PEEP ± 1 hpa Antriebsgas: Typ Druckluft oder Sauerstoff Druck 2 10 bar Flow max. 160 l/min Verbrauch ca. gleich dem ent - sprechenden Minutenvolumen Gasmischer: Gasversorgung Druck Flow O 2, AIR, N 2O 3,5 6,0 bar 11 l/min Frischgas: Gemisch O 2/AIR oder O 2/N 2O Flow (Standby) 0 l/min Flow (Betrieb) 0,2-11 l/min Flow 0,1 l/min Flow ± 10 % rel. O 2-Konzentration 25 100 % O 2 O 2 ± 10 % rel. O 2-Flush mind. 35 l/min Monitoring: Druckmessung: (Anzeige auch in cmh 2 O oder mbar) Messbereich -10 +90 hpa ± 4% oder ± 1hPa 1 hpa Volumenmessung: Messwerte Tidalvolumen Minutenvolumen Atemfrequenz Tidalvolumen, Minutenvolumen, Atemfrequenz 0 2000 ml ± 8% oder ± 0,1 L 0 99 l/min ± 8% oder ± 0,5 l/min 3 100 BPM ± 1 BPM 1 BPM Anästhesiegasmessung (Option): mit/ohne automatische Identifikation der Anästhesiegase Anästhesiegase Halothan, Enfluran, Isofluran, Sevofluran, Desfluran Messbereiche HAL, ISO: 0 8,5 Vol%, ENF, SEV: 0 10 Vol%, DES: 0 22 Vol% ± (0,15 Vol% + 15% rel.) 0, MAK-Wertanzeige minimale Alvolear-Konzentration N 2O-Messung (Option): Messbereich CO 2 -Messung (Option): Messbereich 0 100 Vol% ± (2 Vol% + 8% rel.) 0 10 Vol% ± 0,5 Vol% oder ± 12% rel. 0, Sauerstoffmessung Galvanische Zelle (Option): Messprinzip Galvanische Zelle Messbereich 0 100 Vol% ± oder ± 2% rel. T90 ca. 14 Sekunden Lebensdauer des Sensors ca. 1 4 Jahre, abhängig von der gemessenen Sauerstoffkonzentration Alarme: bei allen Messungen untere Grenze und obere Grenze einstellbar (inspiratorischer und exspiratorischer Wert bei Anästhesiegasen, N 2O, CO 2, inspiratorischer Wert bei O 2-Messung galvanische Zelle) Die Daten unterliegen Änderungen, ohne vorherige Bekanntgabe. 6

General Data: Display coloured, TFT-LCD 6.4 or 12 ( TRIGOdis) Power supply internal accumulator 12V, 3.2 Ah (tightly installed) Power supply external 100 240V, 50/60Hz Power consumption max. 80 VA Operating temperature 15 35 C Dimensions 800x350x400 mm (W x D x H) Weight 33 kg Patient system: Type Volume Relief valve Circle system: Volume (without tubes) Volume absorber Berner Valve bellows in bottle vertical 1.5 l response threshold: 2 mbar approx. 2 l 750 ml 5 50 mbar, VOL, SP Trolley: Dimensions 610x620x1230 mm (W x D x H) Weight 32 kg (with monitor support) Ventilator: Ventilation modes CMV, PCV, SIMV (MMV and ASB in preparation) Tidal volume (CMV) 20 1500 ml (flow: 3 160 l/min) Inspiratory flow (PCV) 10 80 l/min Frequency 3 100 1/min I:E ratio 2:1 1:4 (Ti 0.3 10 s) Inspiratory pause 0 60% Ti PEEP OFF, 3 20 hpa Pressure limitation P MAX (PEEP +5) to 80 hpa Flow trigger (spontaneous mode) 0.3 15 l/min : Tidal volume ± 10% (output bellows in bottle ) P MAX ± 2 hpa or 5% rel. PEEP ± 1 hpa Driving gas: Type Pressure Flow Consumption Gas mixer: Gas supply Pressure Flow compressed air or oxygen 2 10 bar max. 160 l/min approx. equal to the respective minute volume O 2, AIR, N 2O 3.5-6.0 bar 11 l/min Fresh gas: Blend O 2/AIR or O 2/N 2O Flow (standby) 0 l/min Flow (operation) 0.2 11 l/min flow 0.1 l/min flow ± 10 % rel. O 2-concentration 25 100 % O 2 O 2 ± 10 % rel. O 2-Flush min. 35 l/min Monitoring: Pressure measurement: (display also in cmh 2O or mbar) Measuring range -10 +90 hpa ± 4% or ± 1hPa 1 hpa Volume measurement: Measures Tidal volume: Minute volume Breathing rate tidal volume, minute volume, breathing rate 0 2000 ml ± 8% or ± 0.1 l 0 99 l/min ± 8% or ± 0.5 l/min 0 100 BPM ± 1 BPM 1 BPM Anaesthetic agent measurement (option): with/without automatic agent identification Anaesthetic agents Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane Measuring ranges HAL, ISO: 0 8.5 Vol%, ENF, SEV: 0 10 Vol%, DES: 0-22 Vol% ± (0.15 Vol% + 15% rel.) 0. MAC calculation minimum alveolar concentration N 2O-measurement (option): Measuring range CO 2-measurement (option): Measuring range 0 100 Vol% ± (2 Vol% + 8% rel.) 0 10 Vol% ± 0.5 Vol% or ± 12% rel. 0. Oxygen measurement Galvanic Cell (option): Measuring principle Galvanic Cell Measuring range 0 100 Vol% ± or ± 2% rel. T90 approx. 14 seconds Sensor life time approx. 1 4 years, depending on the measured oxygen concentration Alarms: For all measurements lower and upper alarm limits are adjustable (inspiratory and expiratory values for anaesthetic agents, N 2O, CO 2, inspiratory value only for O 2-measurement by galvanic cell). Technical Specifications trigo TRIGOdis Above listed data are subject of change without further notice. 7

Präzisionstechnik fürs Leben. EKU Elektronik GmbH Am Sportplatz 56291 Leiningen Tel.: +49 (0) 6746-10-18 Fax: +49 (0) 6746-84-84 E-Mail: info@eku-elektronik.de www.eku-elektronik.de