SURGE, LIGHTNING ARRESTERS

Größe: px
Ab Seite anzeigen:

Download "SURGE, LIGHTNING ARRESTERS"

Transkript

1 TOP-TECHNIC age 60 W PROTEC LIGHTNING & SURGE ARRESTERS ÜBERSPANNUNGSABLEITER W COMBTEC LIGHTNING & SURGE ARRESTERS W VARTEC SURGE ARRESTERS W FINE PROTECTION ELEMENTS W FINE PROTECTION ELEMENTS FLUSH-MOUNTED SOCKET AND ADAPTER PLUG W DATA LINE PROTECTOR DATEC W DATA LINE PROTECTOR DATEC F-PORT, TV-PORT W SURGE ARRESTERS FOR PHOTOVOLTAIC SYSTEMS

2 It is energy the central element of which is will that produces the miracle that is enthusiasm in all ages. Samuel Smiles, English physician, biographer and social reformer 261 SURGE, LIGHTNING ARRESTERS w CONTENTS GENERAL INFORMATION PROTEC LIGHTNING & SURGE ARRESTERS COMBTEC LIGHTNING & SURGE ARRESTERS POWERTEC OVER VOLTAGE PROTECTION VARTEC SURGE ARRESTERS FINE PROTECTION ELEMENTS DATA LINE PROTECTORS LIGHTNING & SURGE ARRESTERS FOR PV SYSTEMS

3 W LIGHTNING & SURGE ARRESTERS GENERAL INFORMATION W VORSCHRIFTEN REGULATIONS: 262 W SPDS ABLEITER ARE WERDEN DIVIDED IN INTO 3 KLASSEN 3 CLASSES EINGETEILT T Allgemeine General designation Bezeichnung Bezeichnung Designation according gemäß to EN Alte Old Bezeichnung designation Blitzstromableiter Lightning tromableiter arrester Type 1 (Abkürzung: (abbreviation: T1) Ableiterklasse SPD class B B Überspannungsableiter Surge arrester Type 2 (Abkürzung: (abbreviation: T2) Ableiterklasse SPD class C C Fine Feinschutzelement protection element Type 3 (Abkürzung: (abbreviation: T3) Ableiterklasse SPD class D D W ÖVE/ÖNORM Prerequisite Voraussetzung for safe für einen use of bedenkenlosen lightning and surge Einsatz arresters von is testing Blitz- und of the Überspannungsableitern SPDs according to the current ist einedevice Prüfung stan- der dard: Ableiter IEC , nach der EN aktuell gültigen Gerätenorm: IEC , EN The Schrack family of surge protection devices (SPDs) is certified to these standards by an independent testing Die Schrack-Ableiterfamilie ist nach diesen Normen laboratory and thus legitimate bearer of the ÖVE mark. von einem unabhängigen Prüfinstitut zertifiziert ziert und damit berechtigter ter Träger des ÖVE-Zeichens. The Der use Einsatz of lightning von Blitzstrom- and surge und arresters Überspannungsableiter is usually governed ist by meist national in den regulations nationalen for installation, Errichtungsbestimmungen including mungen Austria with geregelt, the ÖVE/ÖNORM so auch in Österreich E , mit erection der ÖVE/ÖNORM of electrical installations E , with Errichtung nominal von voltages elektrischen up to 1000 Anlagen VAC and mit 1500 VDC Nennspannungen (specifically bisfor 1000 surge V arresters AC und 1500 ÖVE/ÖNORM V DC (speziell /A2). für Überspannungsableiter ÖVE/ÖNORM /A2). DC The most important element of the protection philosophy of the ÖVE/ÖNORM E /A2 is the main potential Die ÖVE/ÖNORM E /A2 enthält als wichtigstes Element der Schutzphilosophie den Hauptpotentialausgleichalausgleich equalisation and any additional potential equalisation rails to the extent necessary. The connecting line to the potential equalisation or protective earth conductor rail should be kept as short as possible and without any loops. und soweit notwendig zusätzliche Potentialausgleichsschienen. ausgleichsschienen. Die Verbindungsleitung zur Potentialausgleichs- ausgleichsoder Schutzleiterschiene erschiene sollte möglichst kurz gehalten werden und keine e Schleifenbildung erfolgen. According to ÖVE/ÖNORM E /A2, the maximum continuous voltage (Uc) of SPDs must not exceed 1.45 x U0 Die höchste Dauerspannung (U c ) von SPDs muss lt. ÖVE/ÖNORM E /A2 nicht mehr 1,45 U 0 (U0 = voltage between phase and neutral conductor); it allows a maximum continuous voltage of 1.1 x U0, for example: (U 0 Spannung 230 V x 1.1 = zwischen 253 V -> Phase all SPDs und having Neutralleiter) a continuous betragen, voltage sondern lässt st eine höchste Dauerspannung ung von Uc of 253 V or more may be used (assuming SPD testing 1,1 x Uaccording 0 zu, z.b.:.: to 230 IEC61643). V x 1,1 = 253 V -> alle Ableiter die eine Dauerspannung U c von 253 V oder höher besitzen, dürfen eingesetzt werden (Ableiterprüfung gemäß IEC61643 vorausgesetzt). For insulation measurements, the SPDs must be disconnected from mains. To simplify disconnecting the SPDs, the test Bei Isolationsmessungen class 2 SPDs feature a müssen plug-in design die Ableiter which vom allows Netz them getrennt to be disconnected werden. Umfrom einemains vereinfachte by a simple Trennung manual operation. der Ableiter zu ermöglichen, sind die Testklasse 2 Ableiter in steckbarer Ausführung und können mit einem einfachen Handgriff vom Netz getrennt werden. The proper circuit type per mains system is also defined in the installation regulation. For example, circuit type 4+0 is Die common richtige for Schaltungsart the use of SPDs je Netzsystem in TN-S systems, ist ebenfalls the so-called in der 3+0 Errichtungsbestimmung type in TN-C systems definiert. with PEN So conductors, ist zum and 3+1 in TT systems: Beispiel für die Verwendung von Ableitern im TN-S System die Schaltungsart 4+0 üblich, beim TN-C System mit PEN Leiter die so genannte 3+0 und im TT-System die 3+1 -Schaltung:

4 Connection Anschlussart type für for TN-S System system (Nullung, (zero, PE-N isolated getrennt / 4+0) / 4+0) Connection Anschlussart type für for TN-C System system (Nullung, (zero, PEN PEN-Leiter conductor / 3+0) Connection Anschlussart type für for TT TT System system (3+1) (rail) or (rail) (rail) 263 Extract Auszug from aus EN EN /A2 W ONE EINER OF DER THE WICHITIGSTEN MAJOR POINTS PUNKTE OF DER EN EN /A2 Surge Überspannungsschutzgeräte protection devices against gegen indirect indirekte lightning Blitzeinwirkungen strikes must be installed sind in in jeder every Verbraucheranlage consumer system. zu If central installieren. surge protection Sind in der devices Verbraucheranlage are already installed bereits in zentrale the consumer Überspannungsschutzgeräte system, an installation of installiert, surge protection so ist die devices Installation in each von individual consumer system is not required, but recommended in areas with elevated and high lightning density. Überspannungsschutzgeräten in jeder Einzelverbraucheranlage nicht gefordert, wird aber in Gegenden mit The protection against direct lightning strikes, if required, must be implemented with type 1 surge protection devices erhöhter und hoher Blitzdichte. empfohlen. and, if necessary, additionally with type 2 and/or type 3 surge protection devices. Der Schutz gegen direkte Blitzeinwirkungen, wenn gefordert, ist mit Überspannungsschutzgeräten der Type 1, und wenn erforderlich ergänzend mit Überspannungsschutzgeräten der Typen 2 und/oder 3 zu realisieren. This stipulation requires a least the deployment of type 2 (class C) SPDs in every newly erected or modified electrical installation. Diese Festsetzung verpflichtet zumindest zum Einbau von Klasse C Ableitern in jeder neu errichteten oder veränderten Elektroinstallation. W RELATIONSHIP ZUSAMMENHANG OF THUNDERSTORM VON GEWITTERTAGEN DAYS AND UND LIGHTNING BLITZEINSCHLÄGEN STRIKE (SOURCE: (QUELLE: ALDIS) ALDIS) Anzahl Number der of Gewittertage thunderstorm pro Jahrdays per year Blitzeinschläge Lightning strikes per je km 2 und km 2 Jahr and year T d T d < T d < T d < T d < 35 T d < 35 N g N g < 1,7 1,7 N g < 2,2 2,2 N g < 2,8 2,8 N g < 3,4 N g < 3,4 Blitzgefährdungskategorie Lightning hazard category gering Low Moderate mäßig erhöht Elevated hoch High sehr Very hoch high The Die lightning Bestimmung protection der Blitzschutzklasse class (risk level) is (Gefährdungspegel) determined, when at bei risk Gefahr of direct vonlightning direktenstrikes, Blitzeinwirkungen taking account erfolgt the number unter Berücksichtigung of thunderstorm der days Gewittertage and recorded und lightning registrierten strikes. The Blitzeinschläge. calculation of Die the Berechnung lightning protection der Blitzschutzklasse class can be found kann unter by visiting durchgeführt werden.

5 W EINTEILUNG CLASSIFICATION NG VON OF ABLEITERN SPDS T1 I B W LIGHTNING BLITZSTROMABLEITER ARRESTERS T1 I T1 I B B So-called genannte lightning Blitzstromableiter arresters are used werden against gegen direct direkte lightning Blitzeinwirkungen strikes. The special eingesetzt. feature of Das these Besondere SPDs is their ist die lightning Blitzstromtragfähigkeit current capacity, which dieser has Ableiter, been tested die nach in accordance der internationalen with the international standardisierten standard en SPD Class Ableiterklasse I (IEC ). I (IEC ) Unlike other geprüft SPD types, sind. these Zum Unterschied SPDs are tested zu with anderen the curve Ableitertypen form 10/350 werden μs (this curve diese form Ableiter meets mit the der requirements Kurvenform for 10/350 energy μs and geprüft charge). (diese Critical Kurvenform parameters: erfüllt peak die current Anforderungen (limp), specific für Energie power, and charge. The comparison shows later that these SPDs can lead many times more energy as opposed to the surge arre- und Ladung). Entscheidende Parameter dabei: der Stromscheitelwert (I imp ), die spezifische Energie und die sters. The Schrack lightning arrester series is tested not only for direct, but also for indirect lightning strikes! Ladung. Im späteren Vergleich ist ersichtlich, dass diese Ableiter ein Vielfaches mehr an Energie im Gegensatz zum Überspannungsableiter nungsableiter führen können. Die Schrack Blitzstromableiterserie terserie ist nicht nur für direkte Blitzeinwirkungen en geprüft, sondern auch für indirekte! 264 T2 II W SURGE ÜBERSPANNUNGSABLEITER ARRESTERS NUNGSABLEITER T2 II C T2 II C C SPDs Geprüfte certified Ableiter for class nach II (former Klasse II classification I (alte Bezeichnung C ) have C ) no lightning besitzen current keine Blitzstromtragfähigkeit carrying capacity igkeit and therefore und may dürfen not be daher used nicht against gegen direct direkte lightning Blitzeinwirkung strikes. These SPDs eingesetztesetzt are designed werden. to Diese protect Ableiter consumer dienen systems against zum Schutz remote von strikes Verbraucheranlagen (indirect lightning gegen strikes) Ferneinschläge and voltage surges (indirekte that are Blitzeinwirkungen) caused by switching und operations Überspannungen, or other events en, die in the von electrical Schalthandlungen system. The n oder test surge anderen wave Ereignissen for class II im SPDs elektrischen is standardised System with verursacht the time parameter 8/20 μs and defined by the peak value. The energy carrying capacity of a surge arrester is many times lower than werden. Die Prüfstoßwelle für Testklasse II Ableiter ist mit den Zeitparameter 8/20 μs genormt und durch den that of a lightning arrester. The chart (comparison of test class I (10/350) and test class II (8/20) curve forms) shows a Scheitelwert definiert. Der führbare Energiegehalt gehalt eines Überspannungsableiters ableiters ist um ein vielfaches niedriger, comparison, where the areas under the curves represent a measure of the energy content at the same current peak als jener eines Blitzstromableiters. Einen Vergleich zeigt die Grafik auf Seite 11 (Vergleich Testklasse I (10/350) value. und Testklasse II (8/20) Kurvenform), wobei die Flächen unter den Kurven ein Maß für den Energiegehalt ehalt bei gleichem Stromscheitelwert t darstellt.

6 Comparison Vergleich Testklasse of test class I I (10/350) und and Testklasse test class II II (8/20) Kurvenform curve forms T3 III D W FINE PROTECTION ELEMENT (EQUIPMENT FINE PROTECTION) FEINSCHUTZELEMENT (GERÄTEFEINSCHUTZ) T3 III D 265 For Für sensitive empfindliche end devices, Endgeräte it is necessary ist es notwendig to use a noch coordinated einen koordinierten equipment ordinierten fine Gerätefeinschutz protection addition. setzen. SPD, Dieser marked Ableiter, as T3 or gekennzeichnet III (former classification mit T3 oder D ) is IIIvalidated (alte Bezeichnung by means of D ), a hybrid wirdgenerator mittels and einzu- This defined eines es Hybridgenerators by open-circuit voltage Voc geprüft und and durch short-circuit Leerlaufspannung current Isc. The U very undlow Kurzschlussstrom protection level Iprotects sensitive equipment from damage. It is important when using these devices that the line length to the end equipment to definiert. Der sehr geringe Schutzpegel schützt empfindliche Geräte vor Schäden. Wichtig beim Einsatz dieser oc sc be protected may not to exceed 10 m so that the fine protection element can exert its full protective function. Geräte ist, dass die Leitungslänge zu den schützenden Endgeräten 10 m nicht übersteigen darf, damit das A combination with test class I or test class II SPDs allows the greatest possible protection against voltage surges Feinschutzelement ent seine volle Schutzfunktionn ausüben kann. Eine Kombination mit Testklasse I bzw. Testklasse at the end device. II Ableitern ermöglicht den größtmöglichen Schutz gegen Überspannungen am Endgerät.

7 W SELECTION AUSWAHL AHL MÖGLICHER OF POSSIBLE/NECESSARY / NOTWENDIGER SPD ABLEITER-POSITIONEN POSITIONS IN BUILDINGS IN GEBÄUDEN 266 Sub-distributor Sub-distributor Sub-distributor Main distributor

8 W SCHRACK AUSWAHLMATRIX SELECTION AHLMAT MATRIX FÜR ÜBERSPANNUNGSABLEITER FOR SURGE ARRESTERS Choosing Die Auswahl the der right richtigen SPD is one Ableiter of the ist most eines important der wichtigsten topics when Themen, it comes wenn to protect man seine your Verbraucheranlage consumer system. age With the schützen Schrack möchte. surge protection Mit der Schrack-Überspannungsableiterauswahlmatrix device selection is possible to find the ist right esspd möglich quickly den and richtigen easily. Ableiter schnell und einfach zu finden. START nein No Lightning Blitzschutzanlage protection system vorhanden? available? TN-C SYSTEM STEM TN-S SYSTEM TT-S SYSTEM ja Yes Blitzschutzklasse Lightning protection class I oder I or II 267 PROTEC Dachständer mit Roof rack with overhead line Freileitungsanschluss connection availableuss vorhanden jayes SCHRACK PROTEC / COMBTEC nein No weiter Continue er Blitzschutzklasse Lightning protection III class oder III or IV* Dachüberragendee Roof aerial or conducting Antenne structures oder available? leitende Aufbauten vorhanden? jayes Weitere Further sub-distributors Subverteilereiler available im Abstand at a distance von of > 10 m? > 10 m vorhanden? ja Yes COMBTEC nein No nein No SCHRACK VARTEC Vorgenannte Above-mentioned Bedingungen conditions bei einem available unmittelbar at a directly angrenzenden adjoining building? Gebäude vorhanden? jayes weiter Continue er VARTEC nein No *** SCHRACK SCHRACK fine protection Fi Feinschutzelemente ht elements ente * not in Österreich applicable nicht in Austria anwendbar (ETV), (ETV), ** not ** applicable seit in Austria 2008 insince Österreich 31/12/2008, nicht einsetzbar, *** Independent *** Netzsystem from power unabhängig system

9 W PROTEC LIGHTNING & SURGE ARRESTERS PROTEC W SCHRACK INFO The Schrack Protec series is a combination of lightning and surge arresters (TI + TII). This series was tested and certified in accordance with IEC/EN The use of SCHRACK Protec SPDs is necessary in consumer systems that are classified in lightning protection class (hazard level) I or II (25 ka / 19 ka (10/350) per pole). In indoor mounting not dependent on position the national installation regulations must be followed (Austria: ÖVE/ÖNORM E 8001, ÖVE/ÖNORM 8049, ÖVE/ÖNORM EN 62305). The Protec series has been designed such that there is a complete unit for each network system interconnecting different devices is not necessary. Special rail mounting systems are available for easy rail connection of the SPDs with the residual current circuit breaker. W TECHNICAL TECHNISCHE DATA DATEN 268 Protec TNC Protec TNS Protec TT Validated Geprüft nach according to Testklasse class I + I II + (B II + (B C) + IEC /EN C) Max. continuous Dauerspannung voltage Uc 275 VAC (350 VDC) 275 VAC (350 VDC) 275 VAC (350 VDC) Impulse Impulsstrom current Iimp Iimp 25 ka/pole Pole 25 ka/pole Pole 25 ka/pole Pole ka(gdt) Specific Spezifische power Energie (W/R) (W/R) 156 kj/ /pole Pole 156 kj/ /pole Pole 156 kj/ /pole Pole - 2,5 MJ/ (GDT) Charge Ladung QQ 12,5 As/pole Pole 12,5 As/pole Pole 12,5 As/pole Pole - 50 As (GDT) Max. discharge Ableitstoßstrom current Imax (8/20) Imax (8/20) 100 ka/pole Pole 100 ka/pole Pole 100 ka/pole Pole ka (GDT) Nominal Nennableitstoßstrom discharge current In In (8/20) 25 ka/pole Pole 25 ka/pole Pole 25 ka/pole Pole ka (GDT) Protection Schutzpegel level Up Up (at (at In) In) 1,4 kv 1,4 kv 1,5 kv Max. tightening Anzugsmoment torque 4,5 Nm 4,5 Nm 4,5 Nm Max. back-up Vorsicherung fuse 250 AgL Temperature Temperaturbereich range -40 C C Terminal Klemmenquerschnitt cross-section: 35 mm² 35 (eindrähtig) mm 2 (solid) / 25 mm² (finely (feindrähtig) stranded) Mounting Montage 35 mm 35 DIN mm Schiene DIN rail Degree Schutzart of protection IP20 Dimensions Abmessungen 54 x 90 x x 90 x Dimensions Abmessungen with auxiliary mit HK contact 54 x 98 x x 98 x x 98 x 70 W SCHEMATIC SCHEMATISCHER DIAGRAM AUFBAU With Mit auxiliary HK contact Without Ohne auxiliary HK contact Protec TNC Protec TNS Protec TT

10 W DIMENSIONS ABMESSUNGEN W CONNECTION ANSCHLUSSSCHEMA DIAGRAM 269 W OTHER SONSTIGES ALARM RED REPLACE For Bei SPDs Ableitern with auxiliary mit Hilfskontakt contact, the product endet number die Artikelnummer ends with 1. mit 1. If Wechselt the colour die of the Farbe viewing des window Sichtfensters changes to auf red, Rot, the SPD wurde was overloaded der Ableiter and überlastet must replaced. und muss ersetzt werden. DESCRIPTION MW LIGHTNING PROT. ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. PROTEC BC TNC 275/25 3 I + II TI + TI (B + C) 275 V AC IS PROTEC BC TNC 275/25 + aux. contact 3 I + II TI + TI (B + C) 275 V AC IS PROTEC BC TNS 275/25 4 I + II TI + TI (B + C) 275 V AC IS PROTEC BC TNS 275/25 + aux. contact 4 I + II TI + TI (B + C) 275 V AC IS PROTEC BC TT 275/25 + aux. contact 5 I + II TI + TI (B + C) 275 V AC IS Busbar UEA (BC) between RCCB 3-pole IS Busbar UEA (BC) between RCCB 4-pole IS Order no. blue: on stock, usually ready for delivery on the day of order!

11 W COMBTEC LIGHTNING & SURGE ARRESTERS COMBTEC W SCHRACK INFO The Schrack Combtec series is a combination of lightning and surge arresters (TI + TII). This series was tested and certified in accordance with IEC/EN The use of SCHRACK Combtec arresters is necessary in consumer systems that are classified in lightning protection class (hazard level) III or IV (12.5 ka (10/350) per pole). In indoor mounting not dependent on position the national installation regulations must be followed (Austria: ÖVE/ÖNORM E 8001, ÖVE/ÖNORM 8049, ÖVE/ÖNORM EN 62305). The Combtex series has been designed such that there is a complete unit for each network system interconnecting different devices is not necessary. Special rail mounting systems are available for easy rail connection of the SPDs with the residual current circuit breaker. W TECHNICAL TECHNISCHE DATA DATEN 270 Combtec TNC* Combtec TNS* Combtec TT* Validated Geprüft nach according to Testklasse class I + I + II + II [III] + [III] (B (B + C + + C [D]) + [D]) IEC /EN Max. continuous Dauerspannung* voltage 275 VAC (350 VDC) 275 VAC (350 VDC) 275 VAC (350 VDC) Impulse Impulsstrom current Iimp Iimp (10/350) 12,5 ka/pole Pole 12,5 ka/pole Pole 12,5 ka/pole Pole Specific Spezifische power Energie (W/R) (W/R) 39 kj/ /pole Pole 39 kj/ /pole Pole 39 kj/ /pole Pole Charge Ladung QQ 6,25 As/pole Pole 6,25 As/pole Pole 6,25 As/pole Pole Max. discharge Ableitstoßstrom current Imax (8/20) Imax (8/20) 50 ka/pole Pole 50 ka/pole Pole 50 ka/pole Pole Nominal Nennableitstoßstrom discharge current In In (8/20) 20 ka/pole Pole 20 ka/pole Pole 20 ka/pole Pole [Combined [Kombinierter surge Uoc/Isc] Stoß Uoc/Isc] [10 kv/5 ka] [10 kv/5 ka] [10 kv/5 ka] Protection Schutzpegel level Up Up (at (at In) In) 1,5kV 1,5kV 1,5kV Max. tightening Anzugsmoment torque 4,5 Nm 4,5 Nm 4,5 Nm Max. back-up Vorsicherung fuse 250 AgL Temperature Temperaturbereich range -40 C C C C Terminal Klemmenquerschnitt cross-section 35 mm² 35 (eindrähtig/solid), mm 2 (solid), 25 mm25 2 (finely mm² stranded) (feindrähtig) Mounting Montage 35 mm 35 mm DIN DIN Schiene rail Degree Schutzart of protection IP20 Dimensions Abmessungen 54 x 90 x x 90 x x 90 x 70 Dimensions Abmessungen with auxiliary mit HK contact 54 x 98 x x 98 x x 98 x 70 *bei max. Dauerspannung =335 VAC * for max. continuous voltage Uc = 335 V AC Ausführungen versions, charge sind article alle code anderen to IS210*, technischen all other Daten technical ident data are identical W SCHEMATIC SCHEMATISCHER DIAGRAM AUFBAU With auxiliary Mit HK contact Without Ohne auxiliary HK contact Combtec TNC Combtec TNS Combtec TT

12 W DIMENSIONS ABMESSUNGEN W CONNECTION ANSCHLUSSSCHEMA DIAGRAM 271 W OTHER SONSTIGES ALARM RED REPLACE For Bei SPDs Ableitern with auxiliary mit Hilfskontakt contact, the product endet number die Artikelnummer ends with 1. mit 1. If Wechselt the colour die of the Farbe viewing des window Sichtfensters changes to auf red, Rot, the SPD wurde was overloaded der Ableiter and überlastet must replaced. und muss ersetzt werden. DESCRIPTION MW LIGHTNING PROT. ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. COMBTEC BC TNC 275/ III + (IV) TI + TII (B+C) 275 V AC IS COMBTEC BC TNC 275/ aux. contact 3 III + (IV) TI + TII (B+C) 275 V AC IS COMBTEC BC TNS 275/ III + (IV) TI + TII (B+C) 275 V AC IS COMBTEC BC TNS 275/ aux. contact 4 III + (IV) TI + TII (B+C) 275 V AC IS COMBTEC BC TT 275/ III + (IV) TI + TII (B+C) 275 V AC IS COMBTEC BC TT 275/25 + aux. contact 4 III + (IV) TI + TII (B+C) 275 V AC IS COMBTEC BCD TNC 275/ aux. contact 3 III + (IV) TI + TII + TIII (B+C+D) 275 V AC IS COMBTEC BCD TNS 275/ aux. contact 4 III + (IV) TI + TII + TIII (B+C+D) 275 V AC IS COMBTEC BCD TT 275/ aux. contact 4 III + (IV) TI + TII + TIII (B+C+D) 275 V AC IS Busbar UEA (BC) between RCCB 3-pole IS Busbar UEA (BC) between RCCB 4-pole IS Order no. blue: on stock, usually ready for delivery on the day of order!

13 W POWERTEC DRAINS WITH SEPARATION SPARK GAP (B+C) POWERTEC W SCHRACK INFO POWERTEC arrester with a low level of protection is a selective, twostage constructed T1 + T2 (B + C) arrester, which realizes the protection classes I + II in one device. This eliminates the need for cable lengths under 10m, the decoupling elements required by the use of inert gas-filled, hermetically sealed spark gap, the requirement for a high arresting capacity is achieved at high functional stability. No exhaust port, so no safety distances required. 272 W TIPS & TRICKS The first stage (valve-type) leads impulse currents (up to 4kA), without causing line follow currents. When exceeding a some surge current to (4kA) takes over the second stage (hermetically sealed, inert gas-filled spark gap), the rare dissipation of energy tansienten up to 25kA / 60kA (10/350µs) that can occur with near and direct strikes. To signal is optional in case a potential-free alarm contact (R) with plug connector. The V-wiring can be on the unmarked clamp (the device is not connected to the clamp L / N) by means of the optional two-pole comb type busbar is easy. W CERTIFICATIONS Tested according to E DIN VDE EN and after /98-A1 or IEC and OVE ÖNORM E classification to Class B / C, I + II, T1, T2. W TECHNICAL DATA Protection level: < 2.5 kv Output (R): optional Lightning current: 25 ka, 60 ka (20/350 µs) High insulation resistance of an insulation resistance of > 1010 Ω Maximum continuous operating voltage UC: 335 V ~ Nominal voltage Un: 230V/400V AC 50/60Hz Response time: < 50 ns Maximum permissible line or fuse F2 on stub wiring: 160A gl Maximum permissible line or fuse F3 at V-wiring: 100A gl Operating temperature range: -40 C C Wire strip length: 50 mm² stranded / flexible 35 mm² Material / color: polycarbonate (halogen free) / gray RAL 7035 Protection: IP20 Mounting on 35 mm DIN rail: according to EN

14 W DIMENSIONS AND CIRCUIT DIAGRAMS Abbildung mit Remote Kontakt R R 230VAC/0,5A L1 Stichleitungs - Verdrahtung L1 F1 F2 L1 V - Verdrahtung F3 2polige Kammschiene PE PE N R Wenn Leitungssicherung (F1) 160 A eingesetzt ist, ist die Vorsicherung (F2) nicht zwingend DESCRIPTION MW WEIGHT (kg) EAN CODE AVAILABLE ORDER NO. POWERTEC 25kA Class/II B/C 2 0, IS POWERTEC 25kA+H Class/II B/C 2 0, IS POWERTEC 60kA Class.I/II B/C 2 0, IS POWERTEC 60kA+H Class/II B/C 2 0, IS Busbar 3-fold, for TN-C system IS Busbar 4-fold, for TN-S, TT system IS Order no. blue: on stock, usually ready for delivery on the day of order!

15 W VARTEC SURGE ARRESTERS VARTEC W SCHRACK INFO The Schrack Vartec series is a pure surge arrester series (TII). This series was tested and certified in accordance with IEC/EN The use of SCHRACK Vartec arresters is necessary in every consumer installation, which is newly built or significantly altered. In indoor mounting not dependent on position the national installation regulations must be followed (Austria: ÖVE/ÖNORM E 8001). Through their plug-in design, these arresters are very easy to replace in the case of an overload to an arrester. W TECHNICAL TECHNISCHE DATA DATEN 274 VVP 255 VVP 335 DVP 255 SPD Ableiter-Dauerspannung continuous voltage 255 VAC 335 VAC 255 VAC Nominal Nennableitstoßstrom discharge current In In (8/20) 15 ka/20 ka 15 ka/20 ka 20 ka Max. Grenzableitstrom discharge current Imax Imax (8/20) 30 ka/40 ka 30 ka/40 ka 40 ka Protection Schutzpegel level Up Up bei (la In) 1,3 kv/1,4 kv 1,4 kv/1,65 kv 1,2 kv Response Ansprechzeit time ta <25 ns <25 ns <100 ns Max. Zulässige permissible Umgebungstemperatur ambient temperature -40 C o C Degree Schutzart of protection offen/eingebaut open/installed IP20 / 40 Max. permissible zulässige back-up Vorsicherung fuse 100 A 100 A - Max. terminal Klemmenquerschnitt cross-section // 25 mm² (finely (feindrähtig) stranded) Auxiliary Hilfsschalter switch (optional) 250 VAC / 0,5 A, max. 1,5 mm 2 DIN-rail Verschienbarkeit mountable on beidseitig both sides Max. terminal Klemmendrehmoment tightening torque 2, to 3,0 3.0 Nm (Hauptklemme) (main terminal) W DIMENSIONS ABMESSUNGEN AND UND CIRCUIT SCHALTBILDER DIAGRAMS VVP 255/355 DVP 255 VVP 255/355 DVP 255 with mit auxiliary Hilfsschalter switch with mit auxiliary Hilfskontakt contact

16 W CIRCUIT SCHALTBILDER DIAGRAMS TN-C-Netzsystem MAINS SYSTEM TN-S TN-S-Netzsystem MAINS SYSTEM TN-C/TT-/IT-Netzsystem MAINS SYSTEM Nullung Zeroing Zeroing Nullung Nullung Zeroing Residual-current Fehlerstromschutzschaltung protective circuit Isolationsüberwachungssystem Insulation monitoring system circuit Schaltung W OTHER SONSTIGES ALARM RED REPLACE For Bei SPDs Ableitern with auxiliary mit Hilfskontakt contact, the product endet number die Artikelnummer ends with 1. mit 1. If Wechselt the colour die of the Farbe viewing des window Sichtfensters changes to auf red, Rot, the SPD wurde was overloaded der Ableiter and überlastet must replaced. und muss ersetzt werden. DESCRIPTION MW ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. C-arr. module 15 ka VVP255, IEC 1 TII (C) 255 V AC IS C-arr. module 20 ka VVP255, IEC 1 TI (C) 255 V AC IS C-arr. module 15 ka VVP335, ÖVE 1 TII (C) 335 V AC IS C-arr. module 20 ka VVP335, ÖVE 1 TII (C) 335 V AC IS N-PE arr. module 20 ka DVP255 1) 1 TII (C) 255 V AC IS Base 1-pole for VVP 1 TI (C) IS A Base 1-pole for VVP + aux. contact 1 TII (C) IS A Base 1-pole for DVP 1 TI (C) IS A Base 1-pole for DVP + aux. contact 1 TI (C) IS A Base 3+1 circuit 4 TII (C) IS A Base 3+1 circuit + aux. contact 4 TII (C) IS A Busbar 3-fold, insulated, for TN-C system IS Busbar 4-fold, insulated, for TN-S, TT System IS ) As stated in ÖVE/ÖNORM E8001-1, the requirement of 20 ka applies to the SPD between the neutral conductor and the main earthing bar (N/PE arrester), (PAS) or PE rail without changes, even if overvoltage protection devices with higher nominal discharge current, e.g. 15 ka or 20 ka, are used between the outer conductors and the neutral conductor. Order no. blue: on stock, usually ready for delivery on the day of order!

17 W FINE PROTECTION ELEMENTS IS W SCHRACK INFO Schrack rail-mounted fine protection element (T3) for indoor mounting for the protection of single-phase consumer systems against transient overvoltages. With two protection paths in 1 MW, this Schrack fine protection element is ideal for space-saving installation in small distribution boxes or other DIN rail enclosures. The plug-in design allows easy replacement of the module in case of any overloading of the arrester. W TECHNICAL TECHNISCHE DATA DATEN VMG SPD Ableiterdauerspannung continuous voltage Uc Uc 275 VAC Nominal Nennableitstoßstrom discharge current In In (8/20) 3 ka / Pol Uoc (1.2/50) (1,2/50) 6 kv / Pol Protection Schutzpegel level Up bei (la In) 0,9 kv Response Ansprechzeit time ta ta <100 ns Max. Zulässige permissible Umgebungstemperatur ambient temperature -40 C C Degree Schutzart, of protection offen open/installed / eingebaut IP20 / 40 Max. permissible zulässige back-up Vorsicherung fuse 63 A Max. terminal Klemmenquerschnitt cross-section L, N = 6 mm 2 ; PE = 25/35 mm 2 Auxiliary Hilfsschalter switch (optional) 250 VAC / 0,5 A; max. 1,5 mm 2 W DIMENSIONS ABMESSUNGEN AND UND CIRCUIT SCHALTBILDER DIAGRAMS Internal Innenschaltbild circuit diagram Schematic Prinzipschaltbild diagram F2 nur F2 erforderlich only necessary wenn if F1> F1 63 > AgL 63 AgL DESCRIPTION MW ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. D-arr. module 3 ka, VMG 1 TIII (D) 275 VAC IS Base 1-pole for VMG / VEPG IS Base 1-pole + aux. contact for VMG / VEPG IS I KNOW WHERE TO FIND IT! WITH THE SCHRACK TECHNIK LiVE-PHONE APP Access technical product information at any time and from everywhere See availability and price immediately Order desired products easily Order no. blue: on stock, usually ready for delivery on the day of order!

18 W FINE PROTECTION ELEMENTS FLUSH-MOUNTED BOX AND ADAPTER PLUG IS211450/IS010002/IS W SCHRACK INFO Schrack fine protection elements for flush-mounted boxes are suitable for installation of new and retrofitting existing earthed socket outlets. Through-wiring in the IS enables the connection of additional socket outlets. In case of overload, the built-in signal transmitter signals a defective device. The power supply of end devices is maintained. The Schrack fine protection adapter plug is Ideal for retrofitting a test class 3 arrester for sensitive end devices. The combined protection of power lines and data lines with F-port (TV aerial) or telephone line connection (RJ11) protects all important feed lines to TV set or phone line. Installation always in combination with Protec, Combtec or Vartec arresters! W TECHNICAL TECHNISCHE HE DATA DATEN Flush-mounted UP Dosenableiter box SPD Adapter Zwischenstecker plug ecker IS IS IS Validated Geprüft according nach to Testklasse class III (D) III IEC /EN (D) IEC /EN 643-1/EN Through-wiring Durchverdrahtung YES JA NEIN NO N NEIN NO Max. continuous Dauerspannung voltage Uc 255 VAC 275 VAC Combined Kombinierter surge Stoß Uoc/IscUoc/Isc 4 kv / 2,5 ka 6 kv / 3 ka 6 kv / 3 ka Max. input Eingangsleistung power VA Protection Schutzpegel level Up Up (la (at In /L-N In /L-N ) ) <0,9 kv <0,8 kv <1,25 kv Max. back-up Vorsicherung fuse 16 AgL/gG Temperature Temperaturbereich range -0 C C C C Terminal Klemmenquerschnitt cross-section t 2,5² 1,5² - Signalling Signalisierung Summer Buzzer Summer Buzzer mer LED-Anzeige display Child Kindersicherung safety lock - - YES JA W MOUNTING MONTAGE / / ABMESSUNGEN DIMENSIONS / SCHEMATIC SCHEMATISCHER MOUNTING AUFBAU UP FLUSH-MOUNTED DOSE BOX TV out TV in TEL out TEL in DESCRIPTION ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. Adapter plug 230 VAC /16A TIII (D) 275 V AC IS D-Base outlet arrester 2.5 ka, through-wiring TIII (D) 255 V AC IS D-Base outlet arrester 2.5 ka TIII (D) 255 V AC IS Order no. blue: on stock, usually ready for delivery on the day of order!

19 W DATEC DATA LINE PROTECTOR DATEC W SCHRACK INFO The Datec data line protector is used for data lines such as bus cables, control lines, etc. Since the module can be replaced without interruption (the contacts are closed before the module is contactless), the Datec is also suitable for protection of signal processing inputs (equipment). This solution includes a 12 mm wide module and two protection paths. Through direct contact with an earthed DIN rail, no extra earthing line is required to the module. W TECHNICAL TECHNISCHE HE DATA DATEN 278 IS IS IS IS Description Bezeichnung DATEC DMOD5V D5V DATEC DMOD12V DATEC DMOD24V DATEC DMOD30V Validated Geprüft nach according to Testklasse class III IEC Number Anzahl of der protected gesicherten circuits Kreise 2x2 2x2 (4 (4 Leitungen) wires) Nominal Nennspannung voltage UN UN 5 VDC 12 VDC 24 VDC 30 VDC Max. continuous Dauerspannung voltage Uc 7 VDC 15 VDC 28 VDC 33 VDC Ignition Zündspannungsbereich voltage range (a/b-pg)(a-b) eich (a/b-pg)(a-b) 8-10 V V V V Nominal Nennstrom current IL ILbei at 25 C C 1 A Nominal Nennableitstoßstrom discharge current In I n (8/20) 10 ka Max. discharge Ableitstoßstrom current Imax (8/20) Imax (8/20) 20 ka Residual Restspannung voltage Ures Ures at 5 bei ka (8/20) 5 ka (8/20) 22 V 42 V 70 V 80 V Response Ansprechzeit time ta ta 1 ns Thermal Thermische separator Trennvorrichtung rrichtung Thermoclip Insulation Isolationswiderstand resistance d 5k / 5 VDC 12M / 12 VDC 24M / 24 VDC 30M / 30 VDC Serial Serienimpendanz impedance R R 1,6-2,0 Transverse Querkapazität capacitance C C 50 pf Cutoff Grenzfrequenz frequency fg fg 30 MHz Terminal Klemmenquerschnitt cross-section t 4 mm² (finely (feindrähtig) stranded) Degree Schutzart of protection IP20 Housing Gehäusematerial Thermoplastic V-0 Mounting Montage mm mm DIN DIN Schiene rail Dimensions Abmessungen 95 x 90 x 12 W DIMENSIONS ABMESSUNGEN AND UND CIRCUIT SCHALTBILDER DIAGRAMS DESCRIPTION MW ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. DATEC bus arrester 5 V DC 1 A, 12 mm 0.5 TII (D) 7 V DC IS DATEC bus arrester 12 V DC 1 A, 12 mm 0.5 TIII (D) 15 V DC IS DATEC bus arrester 24 V DC 1 A, 12 mm 0.5 TIII (D) 28 VDC IS DATEC bus arrester 30 V DC 1 A, 12 mm 0.5 TIII (D) 33 VDC IS Order no. blue: on stock, usually ready for delivery on the day of order!

20 W DATEC DATA LINE PROTECTOR F-PORT, TV-PORT (MF) W SCHRACK INFO Just as power lines, all the data lines need to be protected as well. They are also at risk to carry overvoltages and that may destroy electronic devices. Application areas: Lines from TV aerials or satellite dishes to TV set and receiver station. DATEC W TECHNICAL TECHNISCHE HE DATA DATEN IS IS Description Bezeichnung DATEC IEC DATEC F Validated Geprüft nach according to Testklasse class III IEC/EN Coaxial Koaxialverbindung connection IEC (Connection) (Anschluss) 75 F F(Connection) (Anschluss) 75 Insertion Einfügungsdämpfung loss ( ng MHz) ( MHz) <0,5 db Maximum Höchste Dauerspannung continuous nung voltage 48 VAC / 60 VDC Nominal Nennableitstoßstrom discharge current In In (8/20) 5 ka Protection Schutzpegel level at bei In In 550 V Response Ansprechzeit time <5 ns 279 W CONNECTION ANSCHLUSSSCHEMA SSCHEMA DIAGRAM DESCRIPTION ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. DATEC coaxial F connector 75 Ÿ TIII (D) 60 V DC IS DATEC coaxial IEC connector 75 Ÿ TIII (D) 60 V DC IS Order no. blue: on stock, usually ready for delivery on the day of order!

21 W LIGHTNING- & SURGE ARRESTER FOR PHOTOVOLTAIC SYSTEM IS W SCHRACK INFO The SCHRACK PHOTEC series has been developed specifically for the protection of photovoltaic systems and protects them from direct and indirect lightning strikes and power surges. Through proper installation of these surge arresters, the photovoltaic system is protected in areas of lightning protection class (risk level) III and IV. By using 2 terminals per protected pole, a secure connection of cables and equipment can be implemented with ease. The combination of lightning and surge arrester requires no additional arresters between the photovoltaic panels and inverters. W TECHNICAL TECHNISCHE DATA DATEN 280 PHOTEC BC 1000 PHOTEC BC 550 Validated Geprüft according nach to Testklasse class I + I + II (B II (B + C) + IEC /EN C) Max. continuous Dauerspannung voltage 1000 VDC 550 VDC Impulse Impulsstrom current Iimp Iimp (10/350) 12,5 ka/pole Pole 12,5 ka/pole Pole Max. discharge Ableitstoßstrom current Imax Imax (8/20) (8/20) 40 ka/pole Pole 40 ka/pole Pole Nominal Nennableitstoßstrom discharge current IN In (8/20) 20 ka/pole Pole 20 ka/pole Pole Protection Schutzpegel level Up Up (at (at In) In) 2,25 kv 2,0 kv Max. tightening Anzugsmoment torque 4,5 Nm 4,5 Nm Max. back-up Vorsicherung fuse 250 AgL Temperature Temperaturbereich range C C C C Terminal Klemmenquerschnitt cross-section mm² (eindrähtig), (solid) / 25 mm25 2 (finely mm² stranded) (feindrähtig) Mounting Montage 35 mm DIN rail Schiene Degree Schutzart of protection IP20 Dimensions Abmessungen 72 x 90 x x 90 x 70 Dimensions Abmessungen with auxiliary mit HK contact 72 x 98 x x 98 x 70 W SCHEMATIC SCHEMATISCHER STRUCTURE AUFBAU / VERWENDUNGSBEISPIEL SAMPLE APPLICATION PV module DC circuit breaker CONVERTER W OTHER SONSTIGES ALARM RED RESET For Bei SPDs Ableitern with auxiliary mit Hilfskontakt contact, the product endet number die Artikelnummer ends with 1. mit 1. If Wechselt the colour die of the Farbe viewing des window Sichtfensters changes to auf red, Rot, the SPD wurde was overloaded der Ableiter and überlastet must replaced. und muss ersetzt werden. DESCRIPTION MW LIGHTNING PROT. ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. PHOTEC BC 1000/ III + IV TI + TI (B + C) 1000 V DC IS PHOTEC BC 1000/ aux. contact 4 III + IV TI + TI (B + C) 1000 V DC IS PHOTEC BC 550/ III + IV TI + TI (B + C) 550 V DC IS PHOTEC BC 550/ aux. contact 4 II + IV TI + TI (B + C) 550 V DC IS Order no. blue: on stock, usually ready for delivery on the day of order!

22 W SURGE ARRESTER FOR PHOTOVOLTAIC SYSTEMS IS W SCHRACK INFO This SCHRACK PHOTEC series has been developed specifically for the protection of photovoltaic systems and protects them from direct and indirect lightning strikes and power surges. Through proper installation of these surge arresters, the photovoltaic system is protected against transient overvoltages. The plug-in design of the overvoltage protection modules allows easy replacement in case of an overload. The modules must not be replaced under load! Be sure to follow the national installation regulations. W TECHNICAL TECHNISCHE DATA DATEN PHOTEC C 1000 PHOTEC C 550 Validated Geprüft nach according to Testklasse class II II (C) IEC /EN Max. continuous Dauerspannung voltage 1000 VDC 550 VDC Max. discharge Ableitstoßstrom current Imax Imax (8/20)) 40 ka/pole Pole 40 ka/pole Pole Nominal Nennableitstoßstrom discharge current In In (8/20) 20 ka/pole Pole 20 ka/pole Pole Protection Schutzpegel level Up Up (at (at In) In) 4 kv 2,1 kv Max. tightening Anzugsmoment torque 4,5 Nm 4,5 Nm Max. back-up Vorsicherung fuse 125 AgL Temperature Temperaturbereich range -40 C C C + o C Terminal Klemmenquerschnitt cross-section mm² (eindrähtig), (solid) / 25 mm25 2 (finely mm² stranded) (feindrähtig) Mounting Montage mm mm DIN DIN Schiene rail Degree Schutzart of protection IP20 Dimensions Abmessungen 54 x 90 x x 90 x 72 Dimensions Abmessungen with auxiliary mit HK contact 54 x 98 x x 98 x W SCHEMATIC SCHEMATISCHER STRUCTURE AUFBAU / VERWENDUNGSBEISPIEL SAMPLE APPLICATION W OTHER SONSTIGES ALARM RED RESET For Bei SPDs Ableitern with auxiliary mit Hilfskontakt contact, the product endet number die Artikelnummer ends with 1. mit 1. If Wechselt the colour die of the Farbe viewing des window Sichtfensters changes to auf red, Rot, the SPD wurde was overloaded der Ableiter and überlastet must replaced. und muss ersetzt werden. DESCRIPTION MW ARRESTER CLASS UC EAN CODE AVAILABLE ORDER NO. PHOTEC C 1000/20 3 TII (C) 1000 V DC IS A PHOTEC C 1000/20 + aux. contact 3 TII (C) 1000 V DC IS A PHOTEC C 550/20 2 TII (C) 550 V DC IS A PHOTEC C 550/20 + aux. contact 2 TI (C) 550 V DC IS A Order no. blue: on stock, usually ready for delivery on the day of order!

ABB i-bus EIB. EIB Power Supply Units

ABB i-bus EIB. EIB Power Supply Units ABB i-bus EIB EIB Power Supply Units Product Range Overview EIB Power Supplies ABB STOTZ-KONTAKT GmbH, 2002 - SK 029 F 02 E Product Range Overview EIB Power Supplies! EIB Power Supply, 320 ma SV/S 30.320.5!

Mehr

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs 2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with

Mehr

Electrical testing of Bosch common rail piezo injectors

Electrical testing of Bosch common rail piezo injectors Applies to generation CRI 3: Bosch 10-position order number 0 445 115 = CRI 3-16 (CRI 3.0) 1600 bar 0 445 116 = CRI 3-18 (CRI 3.2) 1800 bar 0 445 117 = CRI 3-20 (CRI 3.3) 2000 bar Tools required: Hybrid

Mehr

Protection modular systems for DIN rail and 60mm busbar system DIN-Hutschienen-und 60mm Sammelschienenkomponenten

Protection modular systems for DIN rail and 60mm busbar system DIN-Hutschienen-und 60mm Sammelschienenkomponenten Protection modular systems for DIN rail and 60mm busbar system DIN-Hutschienen-und 60mm Sammelschienenkomponenten 2 Contents / Inhaltsverzeichnis Page Seite 1 2 60mm Classic Busbar System / 60mm Classic

Mehr

ORION three-phase 2-250kVA

ORION three-phase 2-250kVA ORION three-phase 2-250kVA Orion stabilizers are available for different ranges of input voltage fluctuation. Standard models offer a double input connection so that with the same unit two different input

Mehr

BLITZSTROM- & ÜBERSPANNUNGSABLEITER

BLITZSTROM- & ÜBERSPANNUNGSABLEITER KOMPETENZ VERBINDET. BLITZSTROM- & ÜBERSPANNUNGSABLEITER SICHER EFFIZIENT KOMPAKT ENERGIE INDUSTRIE GEBÄUDE ANLAGEN DATEN KABEL LICHT W VIELSEITIGKEIT BRINGT POWER Es ist offensichtlich, dass der technologische

Mehr

Certificate of conformity Generating unit, NS-protection

Certificate of conformity Generating unit, NS-protection Certificate of conformity Generating unit, NS-protection Applicant: Product: Schneider Electric Solar Inverters USA, Inc. 250 South Vasco Road Livermore, California 94551 USA Photovoltaic Inverter with

Mehr

Datenblatt / Data sheet

Datenblatt / Data sheet Seite/Page 1/5 Abbildungen / Illustration Maßzeichnung / Dimensions Produktbeschreibung Product specification Kompaktes, steckbares Relais für den industriellen Einsatz. Compact, pluggable relay for industrial

Mehr

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Newest Generation of the BS2 Corrosion/Warning and Measurement System Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing

Mehr

Electrical testing of Bosch common rail solenoid valve (MV) injectors

Electrical testing of Bosch common rail solenoid valve (MV) injectors Applies to MV injector, generation: -CRI 1.0 / 2.0 / 2.1 / 2.2 -CRIN 1 / 2 / 3, with K oder AK plug Bosch 10-position order number Bosch-Bestellnummer CRI: 0 445 110 xxx Bosch-Bestellnummer CRIN: 0 445

Mehr

splicetec ag Boesch 37 CH-6331 Huenenberg Tel +41 (0) Fax +41 (0)

splicetec ag Boesch 37 CH-6331 Huenenberg Tel +41 (0) Fax +41 (0) Erdungsboxen für Crossbonding und Schirmtrennung Anwendung Starre Erdung Erdung mit Überspannungsableitern Auskreuzung Leistungsmerkmale Kompakte Bauweise Edelstahl Hermetisch abgedichtet 1-Phasen- und

Mehr

Overview thermostat/ temperature controller

Overview thermostat/ temperature controller Thermostat TR-238 The Thermostat TR-238 is a electronic two-level controller for controlling of and in climate control units and vehicles. Voltage range (12V): Voltage range (24V): Control range: Hystereses:

Mehr

INSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示

INSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示 BEDIENUNGSANLEITUNG To comply with the published safety standards, the following must be observed when using this power supply. Um den zur Zeit gültigen Sicherheitsbestimmungen zu genügen, müssen die nachstehenden

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Überspannungsschutzgerät Surge protective device DEHNshield

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. Überspannungsschutzgerät Surge protective device DEHNshield

Mehr

Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen

Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen 15 00 V! Fuse bases for DC Sicherungsunterteile und Sicherungs-Lasttrennschalter für Fotovoltaikanwendungen Pronutec offers his Fuse bases for DC installations up to 1500 V: the 1P NH type Fuse bases with

Mehr

UWC 8801 / 8802 / 8803

UWC 8801 / 8802 / 8803 Wandbedieneinheit Wall Panel UWC 8801 / 8802 / 8803 Bedienungsanleitung User Manual BDA V130601DE UWC 8801 Wandbedieneinheit Anschluss Vor dem Anschluss ist der UMM 8800 unbedingt auszuschalten. Die Übertragung

Mehr

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment Technical Report No. 028-7130 95685-050 of 22.02.2017 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen

Mehr

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen Technical Report No. 028-71 30 95685-350 of 22.02.2017 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen

Mehr

CABLE TESTER. Manual DN-14003

CABLE TESTER. Manual DN-14003 CABLE TESTER Manual DN-14003 Note: Please read and learn safety instructions before use or maintain the equipment This cable tester can t test any electrified product. 9V reduplicated battery is used in

Mehr

Installation Instructions

Installation Instructions EN DE Installation Instructions WLAN Installation Kit, 300 Mbps, 5 GHz, 16 dbi AK-4 Wireless Kit Scope of delivery Junction box AK-4 (1x) 1 Connection board AK-4 CB with 12VDC power supply unit (1x) 2

Mehr

Hazards and measures against hazards by implementation of safe pneumatic circuits

Hazards and measures against hazards by implementation of safe pneumatic circuits Application of EN ISO 13849-1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free

Mehr

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Delta 2.4 W-LAN EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-LAN Installationsvarianten Das DELTA 2.4 W-LAN System kann in verschiedenen Varianten installiert werden:

Mehr

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W

+ + Zuverlässig entkeimen. Reliable desinfection. Linear V UV. Kraftvoll bis 200 W + Powerful up to 200 W Kraftvoll bis 200 W + Powerful up to 200 W + + Kleine Bauform Small size Betriebsanzeige über LED und Meldekontakt Status LED and signal contact Zuverlässig entkeimen. Reliable desinfection. Linear V UV

Mehr

Zehnder ComfoWell 220

Zehnder ComfoWell 220 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for

Mehr

Cleanroom Fog Generators Volcano VP 12 + VP 18

Cleanroom Fog Generators Volcano VP 12 + VP 18 Cleanroom Fog Generators Volcano VP 12 + VP 18 Description & Functional Principle (Piezo Technology) Cleanrooms are dynamic systems. People and goods are constantly in motion. Further installations, production

Mehr

(825M) 2-Draht-Sender

(825M) 2-Draht-Sender Kamera SKS Bussystem 300004 (825M) 2-Draht-Sender 1. Installation Gefahr für Personen durch einen elektrischen Schlag. Verbrennungsgefahr, Geräteschäden und Fehlfunktionen. Bei der Installation sind die

Mehr

JX3-PS1. Installationsanleitung. Version Lieferumfang

JX3-PS1. Installationsanleitung. Version Lieferumfang JX3-PS1 Spannungsversorgungsmodul Jetter AG Kontakte: Gräterstraße 2 E-Mail - Vertrieb: sales@jetter.de D-71642 Ludwigsburg E-Mail - Hotline: hotline@jetter.de Germany Telefon - Hotline: +49(0)7141/2550-444

Mehr

TomTom WEBFLEET Tachograph

TomTom WEBFLEET Tachograph TomTom WEBFLEET Tachograph Installation TG, 17.06.2013 Terms & Conditions Customers can sign-up for WEBFLEET Tachograph Management using the additional services form. Remote download Price: NAT: 9,90.-/EU:

Mehr

HEAG 151, 152, 153, 154 Digital Converter

HEAG 151, 152, 153, 154 Digital Converter Montage- und Betriebsanleitung Installation and operating instructions MB095-11055704 Baumer_HEAG151-152-153-154_II_DE-EN (16A1) HEAG 151, 152, 153, 154 Digital Converter 1-2 Allgemeine Hinweise - Funktionsweise

Mehr

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change! MultiPortSwitch VGA Umschalter Version 1.0 As of April 19 th 2004 Subject to change! Document version: Version Date Name Comment 1.00 29.03.2004 J. Klein Compiled Distributed by: idata industrielle Datensysteme

Mehr

Interconnection Technology

Interconnection Technology Interconnection Technology Register: 23 Date: 25.05.99 Measuring leads from Hirschmann Following measuring leads are replaced by the next generation. Additionally connectors and sockets in the same design

Mehr

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H. ZU 0859 Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H www.knick.de Bauart und Funktion Der Endlagenschalter ZU 0859 wandelt die pneumatischen Endlagen signale,

Mehr

SPINNER MOBILE COMMUNICATION

SPINNER MOBILE COMMUNICATION KOAXIALE ABSCHLUSSWIDERSTÄNDE & DÄMPFUNGSGLIEDER COAXIAL LOADS & ATTENUATORS Abschlusswiderstände übernehmen häufig die Funktion einer Antenne während der Test- oder Einmessphase einer Mobilfunk-Basisstation.

Mehr

IDG. Drehzahlsensor / Speed Sensor

IDG. Drehzahlsensor / Speed Sensor Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor

Mehr

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT Montageanweisung Mounting Instructions Der Umschalter dient zum unterbrechungsfreien Umschalten von Installations-drähten

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. PV-Wechselrichter mit selbsttätiger Freischaltstelle

Mehr

BZ 873. Trainline Interface. Ident Nr.: 3EH-116802 R0001

BZ 873. Trainline Interface. Ident Nr.: 3EH-116802 R0001 Ident Nr.: 3EH-116802 R0001 CH-8108 Dällikon Tel: +41(0)44 8440355 www.bahnelektronik.ch Seite: 1/8 Dritte oder andere Verwertung dieses Dokumentes sind ohne unsere ausdrückliche Zustimmung verboten. B+Z

Mehr

TYTAN TH1. Optische Anzeigen - Hauptschutz betriebsbereit grün - Thermisch überhitzt gelb - Sicherung ausgelöst rot

TYTAN TH1. Optische Anzeigen - Hauptschutz betriebsbereit grün - Thermisch überhitzt gelb - Sicherung ausgelöst rot HAUPTSCHUTZ-Lasttrennschalter mit Sicherungen mit integrierter Überwachungselektronik MAIN PROTECTION-Switch disconnector fuse with integrated monitoring electronic circuit FOTO INFO Optische Anzeigen

Mehr

Attenuator and Distribution System Zehnder ComfoWell 220

Attenuator and Distribution System Zehnder ComfoWell 220 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with sliding profiles for

Mehr

Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Delta 2.4 W-Lan EINBAUANLEITUNG MOUNTINGINSTRUCTIONS Installation des Antennensystems DELTA 2.4 W-Lan Installationsvarianten Das DELTA 2.4 W-Lan System kann in verschiedenen Varianten installiert werden:

Mehr

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016 Overview The Hamburg Süd VGM-Portal is an application which enables to submit VGM information directly to Hamburg Süd via our e-portal web page. You can choose to insert VGM information directly, or download

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / Page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr.. This supplement is only valid in conjunction with page 1 of the. DEHNguard M Typ(en) / Type(s) DG M TN 275; DG M TN 275

Mehr

Produktinformation Access-Gateway. Product information Access gateway AGW 670-0

Produktinformation Access-Gateway. Product information Access gateway AGW 670-0 Produktinformation Access-Gateway Product information Access gateway AGW 670-0 1 2 3 4 2 Deutsch Anwendung Access-Gateway zur physikalischen Trennung von 2 Netzwerken an einem Access-Server. Durch den

Mehr

Parameter-Updatesoftware PF-12 Plus

Parameter-Updatesoftware PF-12 Plus Parameter-Updatesoftware PF-12 Plus Mai / May 2015 Inhalt 1. Durchführung des Parameter-Updates... 2 2. Kontakt... 6 Content 1. Performance of the parameter-update... 4 2. Contact... 6 1. Durchführung

Mehr

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87 Magnetventile Solenoid Valves Betätigungsmagnet Typ 64 für Baureihe 64/79///7 Type 64 for Series 64/79///7 Elektrische Daten 64er Magnetsystem Elektrische Ausführung: gemäß VDE 050, VDE 00 Ansprechstrom:

Mehr

Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W

Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W Operation/Installation Control module DSM 400 for Cooker Hood DA 6000 W de, en M.-Nr. 09 165 660 Inhalt/Contents

Mehr

Überspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden. Circuits using TVS Diodes

Überspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden. Circuits using TVS Diodes Überspannungsschutz für Bauteile und Schaltungen mit Hilfe von TVS-Dioden Overvoltage Protection of Devices and Circuits using TVS Diodes Was ist eine TVS Diode? What is a TVS diode? I F V C V BR V WM

Mehr

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC

DC/AC INVERTER 80VA. Eingangsspannungsbereich Input voltage range 11 14V DC AC-RIDER 80VA WWW.AC-RIDER.COM TÜV Rheinland geprüfte Sicherheit Besondere Merkmale Features 12 VDC Eingang 12 VDC input Hoher Wirkungsgrad High efficiency Überlast / Kurzschlußfest Overload / Short-circuit

Mehr

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

Mehr

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016 Overview The Hamburg Süd VGM Web portal is an application that enables you to submit VGM information directly to Hamburg Süd via our e-portal Web page. You can choose to enter VGM information directly,

Mehr

Tube Analyzer LogViewer 2.3

Tube Analyzer LogViewer 2.3 Tube Analyzer LogViewer 2.3 User Manual Stand: 25.9.2015 Seite 1 von 11 Name Company Date Designed by WKS 28.02.2013 1 st Checker 2 nd Checker Version history Version Author Changes Date 1.0 Created 19.06.2015

Mehr

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719 Fire and explosion hazard ATEX 137 1999/92/EG und ATEX 95 2014/34/EU Danger assessment and determination of explosion protection zone for the test space as well as the installation site ATEX-Check list

Mehr

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten.

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten. Produktdatenblatt Artikel Nr.: 110010 Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W Technische Daten Charakteristik Material Farbe Aluminium Druckguss Weiß-matt Optik im Lieferumfang

Mehr

DATENBLATT / DATASHEET

DATENBLATT / DATASHEET DATENBLATT / DATASHEET AEQUILUX DMX PLAYER 1024 / 2048 Abb. Ähnlich Illustration similar BESCHREIBUNG / DESCRIPTION Der AEQUILUX DMX Player dient zur Lichtsteuerung des AEQUILUX Systems. Das Gerät kann

Mehr

EL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL

EL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL EL-21SY 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Package Contents 1 4. Operation Controls and Functions 2 4.1 Front Panel Diagram 2 4.2 Rear

Mehr

K...<Bestell-Nr. / code>

K...<Bestell-Nr. / code> K...< / code> TECHNISCHE DATEN TECHNICAL DATA Bauartgeprüft gemäß type-approved according IEC/DIN EN 61439-2 VDE 0660-600-2 Nenn-Isolationsspannung AC nominal insulation voltage AC 1000V /50Hz Nenn-Isolationsspannung

Mehr

Überspannungsschutz CONTA-PROTECT

Überspannungsschutz CONTA-PROTECT CONTA-PROTECT Überspannungsableiter CP DS 250 VG Der Überspannungsableiter CP DS 250 VG der Ableiterklasse 1 2 3 (B C D) dient dem zuverlässigen Schutz von Elektroverteilanlagen. Der CP DS 250 VG ist einteilig

Mehr

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten. Produktdatenblatt Artikel Nr.: 341107 Wandaufbauleuchte, Alpha II, Weiß, 220-240V AC/50-60Hz, 100,00 W Technische Daten Charakteristik Material Farbe Weiß Optik im Lieferumfang Elektrische Daten Leistung

Mehr

NH-Sicherungseinsätze der Betriebsklasse gg AC690V mit Kombi-Melder LV HRC fuse-links uzilization class gg AC690V with combi indicator

NH-Sicherungseinsätze der Betriebsklasse gg AC690V mit Kombi-Melder LV HRC fuse-links uzilization class gg AC690V with combi indicator NH-Sicherungseinsätze der Betriebsklasse gg AC690V mit LV HRC fuse-links uzilization class gg AC690V with combi indicator JEAN MÜLLER NH-Sicherungseinsätze der Betriebsklasse gg AC690V sind ab sofort mit

Mehr

Zehnder ComfoWell 320

Zehnder ComfoWell 320 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy to clean Components connected with locking slides for

Mehr

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät Betriebsanleitung RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät ä 2 Operating Instructions RS232 Connection, RXU10 Setting up an RS232 connection

Mehr

HH-Sicherungseinsätze mit Steckverbindern für Freileitungsmontage HV fuse links with plug-connectors for overheadline fitting

HH-Sicherungseinsätze mit Steckverbindern für Freileitungsmontage HV fuse links with plug-connectors for overheadline fitting G- HV fuse links with plug-connectors for overheadline fitting HH1-70 HV fuse links including connectors for overhead line fitting Hochspannungs-Sicherungen mit Anschlussgarnitur bilden einen Set, der

Mehr

Bedienungsanleitung / Manual

Bedienungsanleitung / Manual HAUPTSCHUTZ-Lasttrennschalter mit Sicherungen mit integrierter Überwachungselektronik MAIN PROTECTION-Switch disconnector fuse with integrated monitoring electronic circuit FOTO INFO Optische Anzeigen

Mehr

Analog GSM-Gateway TRF

Analog GSM-Gateway TRF Analog GSM-Gateway TRF GSM gateway for voice- or fax transmission 1 2009 com.sat GmbH Kommunikationssysteme Schwetzinger Str. 19 D-68519 Viernheim www.comsat.de Tel: +49-(0)180-3-768837 The connecting

Mehr

E/A-Bedieneinheit. I/O Control unit 658552 DE/GB 08/02

E/A-Bedieneinheit. I/O Control unit 658552 DE/GB 08/02 E/A-Bedieneinheit I/O Control unit 527429 658552 DE/GB 08/02 Best.-Nr.: 658552 Benennung: DATENBLATT Bezeichnung: D:LP-BED.EINH.-E/A-DE/GB Stand: 08/2002 Autoren: Christine Löffler Grafik: Doris Schwarzenberger

Mehr

SYSTEM COMPONENTS FOR 3~ RECESSED TRACK STANDARD 3~ RECESSED TRACK STANDARD. 3~ Recessed Track Standard

SYSTEM COMPONENTS FOR 3~ RECESSED TRACK STANDARD 3~ RECESSED TRACK STANDARD. 3~ Recessed Track Standard 3~ RECESSED TRACK STANDARD Ceiling cut 40 59 3~ Recessed Track Standard 41 A 5-conductor recessed track with 3 separately switchable circuits and a data bus track. It consists of an extruded aluminum profile

Mehr

Word-CRM-Upload-Button. User manual

Word-CRM-Upload-Button. User manual Word-CRM-Upload-Button User manual Word-CRM-Upload for MS CRM 2011 Content 1. Preface... 3 2. Installation... 4 2.1. Requirements... 4 2.1.1. Clients... 4 2.2. Installation guidelines... 5 2.2.1. Client...

Mehr

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005

Anlage zur Akkreditierungsurkunde D-PL nach DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Anlage zur Akkreditierungsurkunde D-PL-11055-09-00 nach DIN EN ISO/IEC 17025:2005 Gültigkeitsdauer: 09.02.27 bis 18.10.2020 Ausstellungsdatum: 09.02.27 Urkundeninhaber:

Mehr

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]

Made in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar] NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,

Mehr

Walter Buchmayr Ges.m.b.H.

Walter Buchmayr Ges.m.b.H. Seite 1/10 Chapter Description Page 1 Advantages 3 2 Performance description 4 3 Settings 5 4 Options 6 5 Technical data 7 6 Pictures 8 http://members.aon.at/buchmayrgmbh e-mail: walter.buchmayr.gmbh@aon.at

Mehr

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS K la vi er l ac ko p tik AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS ZA 8970 DRUCKS0682.indd 1 05.09.12 15:15 VerpAckunGsinhAlT UKW / UHF / VHF Flachantenne

Mehr

Spezifikation für Freigabe / specification for release

Spezifikation für Freigabe / specification for release 74272722 STAR-FIX LFS mit Sicherheitsverschluß STAR-FIX LFS with Safety Lock DATUM / DATE : 2010-10-07 a 31,0 typ. mm b 35,1 typ. mm c 28,0 typ. mm für Kabeldurchmesser / for cable diameter Ø 8,5-12,5

Mehr

VARIOFACE Systemverkabelung

VARIOFACE Systemverkabelung VARIOFACE Systemverkabelung Systemkabel und Übergabemodule für Yokogawa ProSafe-RS INTERFACE Phoenix Contact Dezember 12 Beinhaltet Crossliste......2 Übergabemodule.. 3 VARIOFACE System Cabling System

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with page 1 of the. DEHNbloc MAXI, DEHNbloc, DEHNgap Typ(en) / Type(s): DB

Mehr

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Blatt / page 2 Dieses Blatt gilt nur in Verbindung mit Blatt 1 des sausweises Nr. This supplement is only valid in conjunction with page 1 of the. Steckdose Socket-outlet Typ(en) / Type(s): 6211..EMS Si/I

Mehr

model protecto I

model protecto I protecto I is an On-line UPS-system in double conversion technology according to DIN EN 62040-3 (VFI-SS-111) with sinus soidal output voltage in each operation mode, LCD display, RS232 interface, USB connection,

Mehr

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren

high potential insulating transformer Hochpotenzial- Trenntrafo bis 80 kv Potenzialtrennung up to 80 kv potential difference Tauscher Transformatoren Hochpotenzial - Hochspannungs - Trenntransformatoren pri - sec und einer Leistung von 1 VA bis 3000 VA Isoliertrafo, Isolationstransformator Einsatzmöglichkeiten Hochspannungstrenntransformatoren werden

Mehr

D4E - Analog Meters for alternating current 4 module

D4E - Analog Meters for alternating current 4 module ANALOGANZEIGER ANALOG METERS Analoganzeiger - D4E für Wechselstrom 4 Modul D4E - Analog Meters for alternating current 4 module D4E Direkte Anzeige des Eingangstroms oder des Nennstroms von externen Stromwandlern

Mehr

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technische Daten. model protecto D 6500 TM 8000 TM TM

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technische Daten. model protecto D 6500 TM 8000 TM TM , 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg protecto D TM is an On-line UPS-system in double conversion technology according to DIN EN 62040-3 (VFI-SS-111) with ratings from 6500 to 10000 VA

Mehr

a) Name and draw three typical input signals used in control technique.

a) Name and draw three typical input signals used in control technique. 12 minutes Page 1 LAST NAME FIRST NAME MATRIKEL-NO. Problem 1 (2 points each) a) Name and draw three typical input signals used in control technique. b) What is a weight function? c) Define the eigen value

Mehr

Ein- und Ausgangsspannung 220-240V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN 60601-1

Ein- und Ausgangsspannung 220-240V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN 60601-1 Produktinformationen Powervar ABCE800-22IEC USV POWERVAR Unterbrechungsfreier Strommanager Der neue Security One USM oder unterbrechungsfreier Strommanager, hat viele neue Funktionen zu bieten. Sie können

Mehr

Attenuator and Distribution System Zehnder ComfoWell 320

Attenuator and Distribution System Zehnder ComfoWell 320 Attenuator and Distribution System Zehnder ComfoWell 32 Benefits All air treatment functions available: attenuator, fine filter, active carbon filter, manifold box Modular design Compact dimensions Easy

Mehr

Technische Daten / Technical data

Technische Daten / Technical data RENTAL INDOOR Die Rental-Lösungen von LEDium sind voll Road-tauglich. Dies bedeutet im Detail ein schnelles Auf- und Abbauen sowie eine hohe Widerstandsfähigkeit. Bei den indoor Varianten kommt ein sehr

Mehr

We are pleased to inform you that the addendum this requires to the existing product approval has now been successfully completed.

We are pleased to inform you that the addendum this requires to the existing product approval has now been successfully completed. MSA AUER GmbH! Thiemannstraße 1! D-12059 Berlin To our customers Name Phone, Fax E-mail Date Malte Kaas (030) 6886-0, -1613 Malte.Kaas@MSAsafety.com 10.12.2014 Duracell MN 1500 Procell Retail availability

Mehr

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL AU-D2 Coaxial/Optical Audio Converter OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Input Panel Diagram 2 3.2 Output Panel Diagram 2 3.3 Switcher

Mehr

Umschaltventile Magnete

Umschaltventile Magnete Umschaltventile Magnete DFE1/6 estellnr. Typ 2-11-12 DFE1/618ES-W22-12VDC 2-11-13 DFE1/618ES-W22-24VDC 24--116 DFE1/618ES-Y22-12VDC 24--117 DFE1/618ES-Y22-24VDC 24--1 DFE1/618ES-W22-12VDC 24--12 DFE1/618ES-W22-24VDC

Mehr

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert.

Artikelnummern / Part Numbers. Bestellbeispiel / Ordering example Y Datum Name. Bearb Kirmse Gepr Dietrich Vert. Beschreibung Description: Verteiler nach Vandalengeschützte Einzeltaster für den Einbau in Frontplatten und Gehäuse mit den Einbaumassen 18mm und 22 mm. Bei diesen Ausführungen bestehen sowohl Betätiger

Mehr

s 120; s 311; s 312; s 330; s 510; s 511; s 530; s 700

s 120; s 311; s 312; s 330; s 510; s 511; s 530; s 700 Technical Report No. 028-7130 95685-250 of 02.12.2016 Client: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen Mr. Sauerbier Manufacturing location: Lukas Hydraulik GmbH Weinstraße 39 D-91058 Erlangen

Mehr

General Information. Ordering. Popular Downloads. Dimensions. Technical

General Information. Ordering. Popular Downloads. Dimensions. Technical S202M-C16 Products Low Voltage Products and Systems Modular DIN Rail Products Miniature Circuit Breakers MCBs General Information Extended Product Type: S202M-C16 Product ID: 2CDS272001R0164 EAN: 4016779550307

Mehr

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type

ELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary

Mehr

PSG 512 A. Stromversorgung / Power supply. Betriebstemperatur / Operation temperature C

PSG 512 A. Stromversorgung / Power supply. Betriebstemperatur / Operation temperature C Multischalter Green Line A Verstärker / Amplifier B Kopfstellen / Headends C Optische Komponenten Multischalter Green Line 5 IN Endmultischalter zur Verteilung von 4 SAT-ZF- (z.b. ASTRA) und terrestrischen

Mehr

Anschluss von Lithium-Ionen-Batterien an ein Sunny Backup System

Anschluss von Lithium-Ionen-Batterien an ein Sunny Backup System Sunny Backup-System SUNNY BACKUP 5000 SUNNY BACKUP 2200 Dieses Dokument gilt für folgende Backup-Wechselrichter: SBU 5000 ab Firmware-Version 7.0 Sicherheitshinweis Anschluss von Lithium-Ionen-Batterien

Mehr

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL AU-D21 Digital Audio Optical Switcher OPERATION MANUAL Table of Contents 1. Introduction 1 2. Features 1 3. Operation Controls and Functions 2 3.1 Front Panel Diagram 2 3.2 Rear Panel Diagram 2 3.3 Side

Mehr

ISLIKER MAGNETE AG - CH-8450

ISLIKER MAGNETE AG - CH-8450 GI-50.10 GI-50.10 1 / Hub / stroke = 10mm 110.5 9 68.5 3x M O 0 M6 18 SW5 O50 O6 Magnet bestromt gezeichnet Solenoid illustrated in energised position 6 max. Hub / stroke = 10mm 110.5 39 68.5 3x M O 0

Mehr

Position switch // ES 411 / EM 411

Position switch // ES 411 / EM 411 Features/Options Metal enclosure ES 411: Slow action A, change-over contact, change-over contact with overlapping or 2 NC contacts with double break EM 411: Snap action, change-over contact with double

Mehr

NPLC NPLC 8500 Netznachbildung NPLC 8500 Line Impedance Stabilization Network

NPLC NPLC 8500 Netznachbildung NPLC 8500 Line Impedance Stabilization Network NPLC 8500 Netznachbildung NPLC 8500 Line Impedance Stabilization Network Beschreibung: Die Netznachbildung NPLC 8500 wurde speziell für PLC-Messungen in Anlehnung an die ITU-T G.9901 entwickelt. Um die

Mehr

Position switch // ES 95 / EM 95

Position switch // ES 95 / EM 95 Features/Options Thermoplastic enclosure Horizontally slotted mounting holes Double insulated X ES 95: Slow action A, change-over contact, change-over contact with overlapping, 2 NC contacts or 2 NO contacts

Mehr