CEDIA CYCLOSPORINE PLUS (HOHER BEREICH)- ANWENDUNG BECKMAN COULTER AU480 /AU680 /AU5800

Ähnliche Dokumente
CEDIA CYCLOSPORINE PLUS (NIEDRIGER BEREICH)- ANWENDUNG BECKMAN COULTER AU480 /AU680 /AU5800

CEDIA MYCOPHENOLSÄURE-ANWENDUNG BECKMAN COULTER AU480 /AU680 /AU5800

QMS EVEROLIMUS-ANWENDUNG BECKMAN COULTER AU480 /AU680 /AU5800

QMS EVEROLIMUS-ANWENDUNG Beckman Coulter AU680 /AU5800

Cystatin C. Packungsbeilage für Cystatin C Immunoassay auf AU Systemen (AU5800, AU680, AU480, AU2700) von Beckman Coulter

Von Microgenics lieferbare Materialien:

Von Microgenics lieferbare Materialien:

Kalibrator C Bestellnummern und Chargennummern 19JAN JAN JAN JAN JAN JAN JAN JAN JAN2013

Weiterführende Informationen zur Progesteron Restandardisierung

EVALUATION SMART Microalbumin

Cortisol Restandardisierung

COMPARISON of SMART HBA1C Analyser against Central Laboratory Analysis November 2008 K.Danzmayer

Cholestech LDX. Kurzanleitung

VARIANTEN DER S/N BERECHNUNG IM CDS THERMO SCIENTIFIC CHROMELEON 7.2

Accu-Chek Inform System. Kurzbedienungsanleitung

- Characteristic sensitive Small temperature differences. - Low Sensitivity 42,8 µv/k for Cu-Constantan

BCA Protein Assay (Pierce)

TASCHENBUCH FÜR MESS- UMFORMER Display für Betrieb und Konfiguration. IM-DE-DTR-PG Überarb. 1.01

Schnelle und effektive

poch-100i Automatischer Hämatologie-Analysator Kurzbedienungsanleitung

Testanleitung. Quantitative Bestimmung der Tumor M2-PK Stuhltest Instruction Manual. Quantitative Determination of the Tumor M2-PK Stool Test

QIAsymphony DSP Virus/Pathogen Kit

HIER TIPPEN, UM DAS PRODUKT ZU SEHEN

Instructions for use. PeliClass human IgG subclass Plus kit PeliClass sheep anti human IgG2 Plus. PeliClass latex sheep anti human IgG4 Plus

Rat Control HZ-DEV99RC Rat control sera suitable for internal control quality of the following HOELZEL ELISAs:

IMMAGE / IMMAGE 800 PeliClass human IgG subclass Plus kit. PeliClass human IgG subclass Plus CAL SET M1896. PeliClass SHP Ab HUM IgG1 M1891

Wichtige Feldkorrekturmassnahme

Kalibrier-Zertifikat Calibration certificate *

Ein neuer Ansatz der Probenvorbereitung

KALIBRIER ZERTIFIKAT CERTIFICATE D ÉTALONNAGE CERTIFICATE OF CALIBRATION

cobas 6000 analyzer series

S-Dis Hotstart Polymerase

Kalibrierschein Calibration Certificate

Thyreoglobulin. Wichtige Werte in der Thyreologie Schilddrüsendialog 2018 Markus Exner

NADAL Hb/Hct plus Analyser

Kurzanleitung zur MATCH IT! Antikörpersoftware

QUANTA Chek ANA Panel

Antikörper-Index-Kontrolle Kontrolle zur Bestimmung des Antikörperindex in der Liquordiagnostik

Wichtige Aspekte der Qualitätskontrolle in der Infektionsserologie. Ilka Richert, Bio-Rad Laboratories GmbH

ARCHITECT CMV Assays. ARCHITECT CMV IgG Avidity Assay Information

CEVERON alpha. Vollautomatischer Gerinnungsanalyzer für clotting, chromogene, turbidimetrische und fluorogene Teste

QUANTA Chek Celiac Panel

ISD Das komplette Testmenü zur Überwachung der Immunsuppressiva. Einfach. Alles. Gut.

Einführung Leistungsmerkmale Aufbau am Beispiel FAT16. Das Filesystem FAT. Peter Schmid. Hochschule für Technik Zürich Studiengang Informatik

Fehlerquellen bei der Bestimmung und Berechnung des Antikörperindex (AI)

Absolute Quantifizierung von 25OH-, 3epi-25OH-, 24,25(OH) 2 -Vitamin D3 und 25OH-Vitamin D2

Arbeitsanleitung. Calretinin ELISA. Enzymimmunoassay für die quantitative Bestimmung von Calretinin in Plasma und Serum 2 8 C

Bevor man an einem Analysengerät Patientenproben messen kann muss das Gerät kalibriert und eine QK bestimmt werden wie oft kalibriert und

DRINGENDE SICHERHEITSINFORMATION (Urgent Field Safety Notice) für IVD

Einfache, intuitive Bedienung: In drei Schritten zum sicheren, Rili-BÄK-konformen Testergebnis

cobas 6000 analyzer series Flexibilität, auf die Sie bauen können.

MyPaclitaxel Control Kit

xchekplus Benutzerhandbuch

Wichtiger Produkthinweis

3 Reaktionen für Kontrollen (1x Negativkontrolle und 2x Positive Control)

Rili-BÄK Fortbildungsprogramm: Neue Richtlinienteile und Erfahrungen. Carmen Hansen und Olaf Kirchner, Bio-Rad Laboratories GmbH

ZLM. A. General information and system parameters

ZLM. A. Allgemeine Informationen und Systemparameter A. General information and system parameter. Zweifrequenz-Laserinterferometer-Messsysteme

Reicht positiv und negativ aus? Qualitätskontrolle bei qualitativen Untersuchungen

Creatinin Enzymatisch (CREA_E)

Stahl-Zentrum. Koksqualität und Hochofenleistung - Theorie und Praxis. Düsseldorf, 05. Dezember Peter Schmöle

SMD Chip-Sicherungen 0402 superflink

Laborchemische Referenzwerte in der klinischen Versorgung

DOAKs Direkte orale Antikoagulantien

Datenblatt. P-series PDU 2.5/4/4AN

Einleitung. I. GENAUIGKEIT Methode

(c) Alle Rechte beim Autor

1-Methylhistamin ELISA

Kalibrierschein Kalibrierzeichen Calibration Certificate Calibration mark

Protokoll Praktikum für Humanbiologie Studenten

3 Reaktionen für Kontrollen (1x Negativkontrolle und 2x Positive Control)

SureFood GMO QUANT Roundup Ready Soya Art. No. S x 50 rxn. User Manual

Thrombozytenfunktionsanalyse mit dem Multiplate System Impedanz-Vollblut-Aggregometrie zur Beurteilung der Thrombozytenfunktion

21-Hydroxylase Ab ELISA

Programmieranleitung CADAS 100 LPG 210

Genauigkeit und Präzision des Accu-Chek Compact Systems und des Accu-Chek Compact Plus Systems. Einleitung. Methode

Gebrauchsanleitung Histamin Elisa BA E

Comparison of individual radiosensitivity of peripheral blood lymphocytes from prostate cancer patients and healthy donors

AMH: DIE NÄCHSTE GENERATION

M. Kaltheuner, Leverkusen

Enzym-Immunoassay zur quantitativen Bestimmung von Haptoglobin in bovinen Milchproben H Tests

Biometrische und Ökonometrische Methoden II Lösungen 2

Calibration Certificate

Externe Kalibrierung vs. festgelegte Kalibrierfaktoren in der LC

Calibration Certificate with reference to ISO Kalibrierschein in Anlehnung an DIN ISO 10012

Messunsicherheit, Gerätevergleich & Co - einfach umgesetzt mittels QC-Datenmanagement

6. Konfiguration von Wireless LAN mit WPA PSK. 6.1 Einleitung

6. Tutoriumsserie Statistik II

Bradford Reagent, 5x

Kurzanleitung zur MATCH IT! DNA-Software

Nor- / Metanephrin ELISA in Urin

RIDA QUICK Soya accessory pack Art. No. Z7103


Transkript:

CEDIA CYCLOSPORINE PLUS (HOHER BEREICH)- ANWENDUNG BECKMAN COULTER AU480 /AU680 /AU5800 Beckman Coulter-Reagens REF A31849 Der CEDIA Cyclosporine PLUS-Assay ist für die quantitative In-vitro-Bestimmung von Cyclosporin in menschlichem Vollblut mit automatischen Analysegeräten für die klinische Chemie vorgesehen. Die Ergebnisse werden zur Unterstützung der Cyclosporin-Therapie bei Patienten mit Nieren-, Leber- oder Herztransplantaten verwendet. In-vitro-Diagnostikum Bestimmungszweck Die Informationen in diesem Anwendungsblatt sind eine Ergänzung zur Packungsbeilage. Die Packungsbeilage enthält Informationen zu Verwendungszweck, Reagenzienlagerung, Aufbereitung des Reagens, Probenentnahme, Probenvorbereitung, Probenlagerung, Qualitätskontrolle sowie weitere Leistungsdaten. Bestellinformationen Artikel CEDIA Cyclosporine PLUS-Assay CsA PLUS-Kalibratorset (hoch) Hohe CsA-Kontrollenkonzentration 4 Hohe CsA-Kontrollenkonzentration 5 Größe R1: 41 ml, R2: 19 ml, Lysereagens: 98 ml, Kal. A niedrig: 2,5 ml, Kal. B niedrig: 2,5 ml 2 x 4 ml pro Konzentration, niedrig und hoch 6 x 2 ml 2 x 8 ml Verdünner 6 x 2 ml 2 x 8 ml Verdünner Beckman Coulter- Nachbestellnummer A31849 979511 979512 979513 AU-Fläschchen 30 ml 63094 AU-Fläschchen 60 ml 63093 Technische Unterstützung Wenden Sie sich für technische Unterstützung an die Beckman Coulter-Vertretung in Ihrer Region. Reagenzienlagerung Informationen zur Reagenzienlagerung sind in der Packungsbeilage zu finden. Seite 1 von 12

Gebrauchsanweisung Verfahren für Analysegerät Informationen zum Betrieb des Analysegeräts sind in dessen Gebrauchsanweisung zu finden. Ausführliche Informationen zur Reagenzienvorbereitung sind in der Packungsbeilage zu finden. Das Reagens vor dem Füllen in die AU-Fläschchen 15 Minuten bei Kühltemperatur (2 bis 8 ºC) äquilibrieren lassen. Reagens R1 und Reagens R2 wie in der folgenden Tabelle gezeigt in die entsprechenden AU-Fläschchen geben: AU-Reagenzienfläschchen CEDIA Cyclosporine-Assaykit R1-Fach R2-Fach Antikörper-/Substratreagens R1 1 Fläschchen (60 ml) Enzymkonjugatreagens R2 1 Fläschchen (30 ml) Warnung: Diese Reagenzien müssen an festen Positionen programmiert werden. Die Thermo-Reagenzienfläschchen nicht direkt im AU-Analysegerät verwenden. Wenn sowohl der niedrige als auch der hohe CsA-Bereich ausgeführt wird, kann das gemeinsame Reagens wie folgt eingerichtet werden: Wählen Sie im Menü Gemeinsame Testparameter die Registerkarte Testname aus. Geben Sie dieselbe Reagenzien-ID für CSAL und CSAH in die Spalte Reagenzien-ID ein. Ergebnisse und Dateninterpretation Probenvorbereitung Die Ergebnisse der Proben werden in ng/ml ausgegeben. Ausführliche Informationen zur Probenvorbereitung sind in der Packungsbeilage zu finden. Die Packungsbeilage ist auf der Thermo Fisher-Website zu finden: www.thermoscientific.com/diagnostics Kalibrierung Das CEDIA Cyclosporine PLUS-Kalibratorkit (hoher Bereich) verwenden. Die Kalibratoren werden wie Patientenproben vorbereitet. Der Wert auf dem Fläschchen muss für die nachfolgenden Parameter verwendet werden. Diese Werte sind chargennummernspezifisch und sollten aktualisiert werden, wenn sich die Kalibrator-Chargennummern ändern. Seite 2 von 12

Anwendungsparameter Parameter Die folgenden Tabellen enthalten die chemischen Parameter des CEDIA Cyclosporine PLUS-Assays (hoher Bereich) für die Analysegeräte Beckman AU480, AU680 und AU5800. CEDIA CYCLOSPORINE PLUS (HOHER BEREICH), AU480 Specific Test Parameters General LIH ISE Range Test Name: CSAH < > Type: Serum Operation: Yes Sample Volume 3 µl Dilution 0 µl OD Limit Pre-Dilution Rate 1 Min. OD -2.00 Max. OD 3.00 Reagents Volume: R1(R1-1) 146 µl Dilution 0 µl Reagent OD limit: First Low -2.00 High 3.00 Last Low -2.00 High 3.00 R2(R2-1) 75 µl Dilution 0 µl Dynamic Range Low 450 High 2000 Correlation Factor A 1 B 0 Wavelength: Pri. 570 nm Sec. 660 nm Factor for Maker A 1 B 0 Method: FIXED1 Reaction slope: + Onboard Stability # Days # Hour Measuring Point 1: First 24 Last 27 LIH Influence Check # Measuring Point 2: First Last Lipemia Linearity: % Icterus No Lag Time: No Hemolysis Specific Test Parameters General ISE Range Test Name: CSAH < > Type: Serum Value/Flag: # Level L: # Level H: # Specific Ranges: Panic Value From To Sex Year Month Year Month Low High Low High 1. # # # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. No demographics # # 8. Not within expected values # # Unit ng/ml Decimal Places # Seite 3 von 12

CEDIA CYCLOSPORINE PLUS (HOHER BEREICH), AU480 (Fortsetzung) Calibration Specific General ISE Test Name: CSAH < > Type Serum Use Serum Cal. Calibration Type: AA Formula: Y = AX+B Counts: 2 <Calibrator Parameters> Slope Check + Calibrator OD Conc Factor Range Low High Allowable Range Check Point 1: # * -99999 99999 Reagent Blank Point 2: # * Calibration Point 3: Advanced Calibration Point 4: Operation Point 5: Interval (RB/ACAL) Point 6: Point 7: Point 8: Point 9: Point 10: <Point Cal. For Master Curve> No. of Correction Points Use Master Curve Lot Calibration Calibrator OD Conc OD Range Stability Low High Reagent Blanks # Day # Hour Point 1: Calibration # Day # Hour Point 2: MB Type Factor: 1-Point Calibration Point With CONC-0 # Anwenderdefiniert * Chargenspezifische Kalibratorwerte Seite 4 von 12

CEDIA CYCLOSPORINE PLUS (HOHER BEREICH), AU680 Specific Test Parameters General LIH ISE Range Test Name: CSAH < > Type: Serum Operation: Yes Sample Volume 3 µl Dilution 0 µl OD Limit Pre-Dilution Rate 1 Min. OD -2.00 Max. OD 3.00 Reagents Volume: R1(R1-1) 146 µl Dilution 0 µl Reagent OD limit: R2 Volume 75 µl Dilution 0 µl First Low -2.00 High 3.00 Last Low -2.00 High 3.00 Dynamic Range Low 450 High 2000 Common Reagent Type None Name Correlation Factor A 1 B 0 Wavelength: Pri. 570 nm Sec. 660 nm Factor for Maker A 1 B 0 Method: FIXED1 Reaction slope: + Onboard Stability # Days # Hour Measuring Point 1: First 24 Last 27 LIH Influence Check # Measuring Point 2: First Last Lipemia Linearity: % Icterus No Lag Time: No Hemolysis Specific Test Parameters General ISE Range Test Name: CSAH < > Type: Serum Value/Flag: # Level L: # Level H: # Specific Ranges: From To Panic Value Sex Year Month Year Month Low High Low High 1. # # # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. No demographics # # 8. Not within expected values # # Unit ng/ml Decimal Places # Seite 5 von 12

CEDIA CYCLOSPORINE PLUS (HOHER BEREICH), AU680 (Fortsetzung) Calibration Specific General ISE Test Name: CSAH < > Type Serum Use Serum Cal. Calibration Type: AA Formula: Y = AX+B Counts: 2 <Calibrator Parameters> Slope Check + Calibrator OD Conc Factor Range Low High Allowable Range Check Point 1: # * -99999 99999 Reagent Blank Point 2: # * Calibration Point 3: Advanced Calibration Point 4: Operation Point 5: Interval (RB/ACAL) Point 6: Point 7: Point 8: Point 9: Point 10: <Point Cal. For Master Curve> No. of Correction Points Use Master Curve Lot Calibration Calibrator OD Conc OD Range Stability Low High Reagent Blanks # Day # Hour Point 1: Calibration # Day # Hour Point 2: MB Type Factor: 1-Point Calibration Point With CONC-0 # Anwenderdefiniert * Chargenspezifische Kalibratorwerte Seite 6 von 12

CEDIA CYCLOSPORINE PLUS (HOHER BEREICH), AU5800 Parameters Specific Test Parameters General LIH ISE HbA1c Calculated Test Range Test Name: CSAH < > Type: Serum Operation Yes Sample Volume 2.7 µl Dilution 0 µl OD Limit Pre-Dilution Rate 1 Diluent Bottle # Min.OD -2.00 Max.OD 3.00 Rgt. Volume R1(R1-1) 131 µl Dilution 0 µl Reagent OD Limit R1-2 µl Dilution µl First Low -2.00 High 3.00 Last Low -2.00 High 3.00 R2(R2-1) 67 µl Dilution 0 µl Dynamic Range Low 450 High 2000 Common Rgt. Type None Name Correlation Factor A 1 B 0 Wavelength Pri 570 nm Sec. 660 nm Factor for Maker A 1 B 0 Method FIXED1 Reaction Slope + Onboard Stability Period # Day # Hour Measuring Point1 1 st 24 Last 27 LIH Influence Check # Measuring Point2 1 st Last Lipemia Linearity Limit % Icterus Lag Time Check No Hemolysis Parameters Specific Test Parameters General LIH ISE HbA1c Calculated Test Range Test Name: CSAH < > Type: Serum Value/Flag: # Level Low # High # Specific Ranges: From To Sex Year Month Year Month Low High ο 1. # # # # # # # ο 2. # # # # # # # ο 3. # # # # # # # ο 4. # # # # # # # ο 5. # # # # # # # ο 6. # # # # # # # 7. Standard demographics # # 8. Not within expected values # # Panic Value Low # High # Unit ng/ml Decimal Places # Seite 7 von 12

CEDIA CYCLOSPORINE PLUS (HOHER BEREICH), AU5800 (Fortsetzung) Parameters Calibrators General ISE Calibration Specific Calibration Parameters Test Name: CSAH < > Type Serum Cuvette. Use Serum Cal. Calibration Type: AA Formula: Y=AX+B Counts: 2 <Calibrator Parameters> Range Calibrator OD Conc Low High Slope Check + Point 1: # * -99999 99999 Point 2: # * Allowance Range Check Point 3: Point 4: Reagent Blank Point 5: Calibration Point 6: Point 7: Advanced Calibration Point 8: Operation No Point 9: Point 10: Interval (RB/ACAL) <Point Cal. For No. of Correction Points Use Master Curve Lot Calibration Master Curve> OD Range Calibrator OD Conc Low High Stability Point-1 Reagent Blank # Day # Hour Point-2 Calibration # Day # Hour MB Type Factor: 1-Point Calibration Point None with Conc-0 # Anwenderdefiniert * Chargenspezifische Kalibratorwerte Seite 8 von 12

Ergebnisse und Dateninterpretation Leistungsdaten Weitere Informationen zu den Ergebnisse und zur Dateninterpretation sind in der Packungsbeilage zum CEDIA Cyclosporine PLUS-Assaykit zu finden. Beispielkalibrierungskurve, CsA (hoher Bereich) (AU480): Extinktion Kalibrierungskurve 0,40 0.40 0,35 0.35 0,30 0.30 0,25 0.25 0,20 0.20 0,15 0.15 0,10 0.10 0,05 0.05 0,00 0.00 25,7 25.7 525.7 525,7 1025.7 1025,7 1525.7 1525,7 2025.7 2025,7 2525,7 2525.7 Wert (ng/ml) Seite 9 von 12

Präzision Diese Grade an Präzision und Gleichwertigkeit wurden in einem typischen Testverfahren mit einem AU-System erzielt und sind nicht dazu bestimmt, die Leistungsdaten dieses Reagens darzustellen. Die Kontrollproben wurden in Replikaten von 2 an 20 Tagen zweimal täglich (insgesamt n = 80) getestet. Die Ergebnisse sind in der folgenden Tabelle zusammengefasst: Kontrollen Kontrolle 4 Kontrolle 5 AU480 Mittelwert (ng/ml) Intraassay-SD (ng/ml) Intraassay-VK (%) Gesamt-SD (ng/ml) Gesamt-VK (%) 696 1.594 18,8 35,1 2,7 2,2 55,9 139,4 8,0 8,7 AU680 Mittelwert (ng/ml) Intraassay-SD (ng/ml) Intraassay-VK (%) Gesamt-SD (ng/ml) Gesamt-VK (%) 709 1.608 31,5 49,6 4,4 3,1 53,1 138,8 7,5 8,6 AU5800 Mittelwert (ng/ml) Intraassay-SD (ng/ml) Intraassay-VK (%) Gesamt-SD (ng/ml) Gesamt-VK (%) 677 1.557 21,8 36,5 3,2 2,3 52,8 87,5 7,8 5,6 Seite 10 von 12

Linearität Zehn Kalibratorkonzentrationen wurden gegen eine einzige Kalibrierungskurve ausgeführt, und die Linearität wurde berechnet. Der analytische Bereich dieses Assays beträgt 450 bis 2000 ng/ml. Bei Proben, bei denen die Wiederfindung über oder unter dem Assay-Bereich liegt, werden Fehlermeldungen angezeigt. Der Cyclosporine PLUS-Assay (hoher Bereich) führte auf dem AU480 zu einer Wiederfindung von 103 110 % der erwarteten Werte. Der Cyclosporine PLUS-Assay (hoher Bereich) führte auf dem AU680 zu einer Wiederfindung von 99 110 % der erwarteten Werte. Der Cyclosporine PLUS-Assay (hoher Bereich) führte auf dem AU5800 zu einer Wiederfindung von 98 109 % der erwarteten Werte. Genauigkeit und Korrelation 114 Blutproben wurden mit dem CEDIA Cyclosporine PLUS-Assay (hoher Bereich) im Beckman Coulter AU480 untersucht und mit der Referenzmethode Hitachi 911 getestet. 115 Blutproben wurden mit dem CEDIA Cyclosporine PLUS-Assay (hoher Bereich) im Beckman Coulter AU680 untersucht und mit der Referenzmethode Hitachi 911 getestet. 115 Blutproben wurden mit dem CEDIA Cyclosporine PLUS-Assay (hoher Bereich) im Beckman Coulter AU5800 untersucht und mit der Referenzmethode Hitachi 911 getestet. Eine Deming-Regressionsanalyse für CsA HR lieferte die folgende Ergebnisse: Beckman Coulter AU480 = 1,03*(Hitachi 911) + 90,96 mit einem Korrelationskoeffizienten von 0,971 Beckman Coulter AU680 = 1,07*(Hitachi 911) + 30,23 mit einem Korrelationskoeffizienten von 0,968 Beckman Coulter AU5800 = 1,05*(Hitachi 911) + 9,00 mit einem Korrelationskoeffizienten von 0,975 Seite 11 von 12

Weitere Informationen Wichtiger Hinweis Da Beckman Coulter weder das Reagens herstellt noch Qualitätskontrollen oder andere Prüfungen mit einzelnen Chargen durchführt, schließt Beckman Coulter jegliche Haftung für Qualitätsminderungen der gewonnenen Daten aus, die durch die Leistung des Reagens, Abweichungen zwischen den Reagenzienchargen oder Protolländerungen des Herstellers entstehen. Versandschaden Bitte benachrichtigen Sie umgehend das Supportzentrum von Beckman Coulter, wenn Sie dieses Produkt beschädigt erhalten haben. 2016 Thermo Fisher Scientific, Inc. Alle Rechte vorbehalten. Die Systeme der AU-Serie sind eingetragene Marken von Beckman Coulter. CEDIA ist eine eingetragene Marke von Roche. Alle anderen Marken sind Eigentum von Thermo Fisher Scientific und ihren Tochtergesellschaften. EC REP Thermo Fisher Scientific Oy, Ratastie 2, P.O. Box 100, 01621 Vantaa, Finland Tel: +358-9-329100/Fax: +358-9-32910300 Ende Seite 12 von 12