Hazards and measures against hazards by implementation of safe pneumatic circuits

Ähnliche Dokumente
Electrical tests on Bosch unit injectors

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. edraulic rescue equipment

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

Steuerung von Rolläden / Controlling Roll-down Shutters

technical documents for extraction and filter devices type series 1000

Bewässerung von Gewächshauspflanzen / Irrigation system for greenhouse plants

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

Electrical testing of Bosch common rail piezo injectors

Snap-in switch for switches PSE, MSM and MCS 30

Electrical testing of Bosch common rail solenoid valve (MV) injectors

s 120; s 311; s 312; s 330; s 510; s 511; s 530; s 700

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens

FEM Isoparametric Concept

Electrical testing of Bosch common rail Injectors

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Bedienungsanleitung Manual

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

rot red braun brown rot red RS-8 rot red braun brown R S V~

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

Tube Analyzer LogViewer 2.3

Rev. Proc Information

Lukas Hydraulik GmbH Weinstraße 39 D Erlangen. Mr. Sauerbier. Lukas Hydraulik GmbH Weinstraße 39 D Erlangen

FEM Isoparametric Concept

Copyright by Max Weishaupt GmbH, D Schwendi

Tenting plugging Filling

Schaufensterbeleuchtung / Shop Window Lighting

Number of Maximal Partial Clones

OPERATING INSTRUCTIONS

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2.

Produktinformation Access Upgrade Video. Product information Access licence for video upgrade AUV T AUV F

Installationsanleitung / installation manual - DIMMbox

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T

technical documents for extraction and filter devices type series 220

Walter Buchmayr Ges.m.b.H.

How-To-Do. Hardware Configuration of the CPU 317NET with external CPs on the SPEED Bus by SIMATIC Manager from Siemens

Konfiguration von eduroam. Configuring eduroam

Typenreihe GH Lifting Solenoids

Shock pulse measurement principle

Overview thermostat/ temperature controller

Ex-Barriere für Diagnoseeinheit SITRANS DA400 / Ex-barrier for diagnostics unit SITRANS DA400 7MJ2010-1AA 0032

Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit Pool water quality the German philosophy

Application Note. Import Jinx! Scenes into the DMX-Configurator

Hinweisblatt. Für den Einsatz des MAX! Heizungssteuerungssystems haben Sie zwei Alternativen: Die MAX! Einzelraumlösung und die MAX! Hauslösung.

Interpolation Functions for the Finite Elements

Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W

Bosch Rexroth - The Drive & Control Company

Kuhnke Technical Data. Contact Details

CABLE TESTER. Manual DN-14003

Operating instructions Pneumatic preselect counter Method of counting - adding, with stationary preset number for Panel mounting Type PZV-S-E

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series

Spezifikation für Freigabe / specification for release

MQ964..GB MQ965..GB. en Operating instructions ar

p^db=`oj===pìééçêíáåñçêã~íáçå=

Description of the PHOTOSONICS 4B - 35mm Highspeed Camera

How-To-Do. Communication to Siemens OPC Server via Ethernet

How-To-Do. OPC-Server with MPI and ISO over TCP/IP Communication. Content. How-To-Do OPC-Server with MPI- und ISO over TCP/IP Communication

EINBAUHINWEISE INSTALLATION INSTRUCTIONS

ERHARD is a company of. Datasheet ERHARD ECR check valve

H o c h s c h u l e D e g g e n d o r f H o c h s c h u l e f ü r a n g e w a n d t e W i s s e n s c h a f t e n

Quadt Kunststoffapparatebau GmbH

SICHERHEITSVENTILE OHNE BAUTEILPRÜFUNG SAFETY VALVES WITHOUT TEST CERTIFICATE. Type 602 E / Type 601 T for liquids, gaseous media and steam

Typenreihe GH Lifting Solenoids

Einbauanleitung / Installation Instructions Kit CM44xR

Magic Figures. We note that in the example magic square the numbers 1 9 are used. All three rows (columns) have equal sum, called the magic number.

Wandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply

Wissenschaftliche Dienste. Sachstand. Payment of value added tax (VAT) (EZPWD-Anfrage ) 2016 Deutscher Bundestag WD /16

Umschaltventile Magnete

KOMPETENZBROSCHÜRE Competence brochure

B032/Trg B025 B026 I5 B :00s B028 B014/R B023. B024 Trg B031 B030. Rem = off. 35:00s+ B008 B010. B001/Trg

Guard-locking mechanism HST-TS2 Ident. No

Released energy meters for PIKO IQ / PLENTICORE plus

Finite Difference Method (FDM)

1 Allgemeine Information

Mechanisch betätigte Ventile Typ 74 NW 2 3/2-Wege Sitzventile Direktgesteuert

Cleaning & Disinfection of Eickview Videoendoscopes

Registration of residence at Citizens Office (Bürgerbüro)

ASP-1750 HUB-POSITIONIEREINHEIT BETRIEBSDRUCK 4-8 BAR

Sporadischer Neustart von WPC-Geräten FINALE LÖSUNG

Umschaltventile Magnet

Cleanroom Fog Generators Volcano VP 12 + VP 18

Kuhnke Technical Data. Contact Details

Control shut-off butterfly valves DN 50 DN 400 PN

The luminaire must be installed and main - tained by a suitably qualified person in compliance with latest installation and safety regulations.

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Field-Circuit Coupling for Mechatronic Systems: Some Trends and Techniques

R OLLOS R OLLER BLINDS

Data Mining and Data Analysis using the Example of cross-border Traffic Management during Extreme Weather Events

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient

Integrierter Wasseranschluss für Twin Cover

Dynamic Hybrid Simulation

UV-MASTER. Härtung von Foliendekoroberflächen mit UV-Strahlung UV-Curing of film decorated mold parts (IMD/IML)

ASP-1050 HUB-POSITIONIEREINHEIT BETRIEBSDRUCK 4-8 BAR

1. Hardware Configuration Hardware-Konfiguration Software-Konfiguration Software Configuration...4

PELTIER-HOCHLEISTUNGSMODULE

IR RECEIVER Bedienungsanleitung User s Manual

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016

Transkript:

Application of EN ISO 13849-1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free of charge. For this reason, we do not assume any liability or responsibility for whatever legal reason, especially not for correctness of contents, faultlessness, completeness or technical or commercial usability of this guideline.!1

ISO 13849-1 in pneum. control systems Scope of EN ISO 13849 for pneumatic systems The area of valves in particular should be considered as safety-related part of the control system, and specifically the valves which control hazardous movements or states. The drive elements and components for energy conversion and transmission generally lie outside the scope of the standard. Maintenance units for conditioning of compressed air must be considered from a safety perspective in conjunction with the valve area. For possible energy conversions to be controlled with consideration for safety aspects, an exhaust valve is frequently used in conjunction with a pressure switch. Source: BGIA Report!2

Example 1 Stop of cylinder movement by pressurizing both sides (Category 2), possible PL a- d In case of pressure drop, the non- return valves 1V2 and 1V5 avoid exhausting - > cylinder is kept in position. 1 channel, 100-fold test of SF before need, 0 failure safety between test phases The pressure regulator 1V1 reduces supply pressure so that there is a balance of forces cylinder movement is stopped 1V4 1V3 1S2!3

Example 2a Safe retraction of a cylinder (Category 3), possible PL a- d The cylinder 1Z can be retracted by non- operating of valve 1V1 or non- operating of valves 2V3 and 2V1. On permanent operation of valves 2V3 and 2V1, the cylinder 1Z can be driven by valve 1V1. The retraction of the cylinder is redundant. Further safety function: redundant avoidance of unexpected start- up, (category 3).!4

Example 2b Protection against unexpected start- up (Category 3), possible PL a- e The cylinder can be kept in initial position with both switching positions of valve 2V2. The cylinder can only be extracted with full power by operating the valves 1V1, 2V3 and 2V1.!5

Example 3 Safe stop in upper position by clamping and one- sided pressurizing (Category 3, Category 4 attainable), possible PL a- e Clamping unit 2A can be released by valve 2V with supply pressure at pressure switch 2S1 and a control system 2S2. Non- return valve 1V1 avoids exhausting on pressure drop.!6

Example 4 Safe stop of a cylinder in upper position by clamping and one- sided pressurizing (Category 3, Category 4 attainable), possible PL a- e Approaching the upper end- position in basic switching position of valves 1V3 and 1V6. Clamping unit 2A which can be released by valve 2V with supply pressure at pressure switch 2S1 and a control system 2S2.!7

Example 5 Safe exhausting (Category 3), possible PL a- e The system is exhausted in the basic switching position of the valves, 2 paths for exhausting: 1.) Via non- return valves 2V2 and 2V3 and valve 2V1 (the minimum opening pressure of the non- return valves is to be respected). 2.) Via valve 1V. Retraction and extraction of the cylinder is only possible with combined operation of 2V1.!8

Example 6 (BGIA Example 8.2.14) Protection against unexpected start- up of the cylinder (Category 3), possible PL a- e 2 possibilities to stop / hold the cylinder: 1. On pressure drop and in the basic switching position of valve 2V, the cylinder is held by clamping unit 2A. 2. In closed (middle) position of the valve 1V1, the cylinder is stopped by blocking up the air. The cylinder can only be extracted or retracted by combined operation of 1V1 and 2V.!9

Example 7 (BGIA Example 8.2.25) Safe stop / holding by two- channel block- up of air (Category 3), possible PL a- e 2 possibilities for stopping / holding the cylinder 1. For non- operation of 2V1, the valves 2V2 and 2V3 are in closed position. 2. For non- operation of 1V, the valve is closed in mid- postion.!10

Example 8 (BGIA Example 8.2.25) Safe stop / holding by 2- channel block- up of air + extension (Category 3), possible PL a- e 2 possibilities for stopping / holding the cylinder: 1. On non- operating of 2V1, the valves 2V2 and 2V3 are in closed position. 2. On non- operation of 1V, the valves is closed in mid- position. Extended options: Release of pilot air for 1V and compressed air supply for 2V1 by operating 0V1. Controlled start- up by filling unit 0V3.!11

Example 9 Safe stop / holding by 2- channel block- up of air + extension (Category 3), possible PL a- e Stop / Hold the cylinder On non- operation of 1V5, the valve is in closed mid- position. If 2V2 and 2V3 are operated, the valve 1V1 closes up in mid- position. Extended option: targeted exhausting on pressure drop during setting mode, e.g. for rescue of persons by switching 1V5.!12

Example 10 Safe stop / holding by 2- channel block- up of air + extension (Category 3), possible PL a- d Stop / Hold the cylinder Close up via valve 2V6 and non- return valve 2V10. On non- operation of 1V1, the valve is closed in mid- position. Exended option: Targeted exhausting on pressure drop by switching 2V6 and controlled movement of the cylinder into start- up position by one- sided throttled pressurizing via 2V8.!13

Example 12 Avoid unexpected operation by blocking up pilot air (Category 2), possible PL a- d Block- up of pilot air 1. The pilot air is blocked through 2V in basic switching position, the valve 1V1 cannot be operated.!14

Example 13 Avoid unexpected operation by blocking up pilot air + safe stop/holding by two- channel block- up of air (Category 3), possible PL a- e Block- up of pilot air 1.In the basic position, the pilot air is blocked through 2V, the valves 1V and 3V1 cannot be operated. Block- up of air 2. On non- operating of 3V1, the valves 3V2 and 3V3 are in closed position. 3. On non- operating of 1V, the valve is closed in mid- position.!15