ULT JUMBO Filtertrolley 2.0 MED

Ähnliche Dokumente
technical documents for extraction and filter devices type series 220

technical documents for extraction and filter devices type series 1000

INCLUDES: Fully assembled 4 wheels for mobile use Power cable

TECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS

T C. uropean Technical Center for Engineering & Distribution GmbH. ETC-Distribution

Schadstoffabsaugsysteme. INTRON Jena GmbH

UWC 8801 / 8802 / 8803

OIL-FREE MEDICAL compressors

Serviceinformation Nr. 02/11

02. Liquid Handling Dosiertechnik

Zehnder ComfoWell 320

Handwerk Trades. Arbeitswelten / Working Environments. Green Technology for the Blue Planet Clean Energy from Solar and Windows

Cleanroom Fog Generators Volcano VP 12 + VP 18

Heizcontainer Serie XS Heating container series XS ENERLOG B i omasseh eizcontainer

Pneu. Linearantriebe mit externer Gleitführung Baureihe PLS

Ein- und Zweifamilienhäuser Family homes

Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen

Kuhnke Technical Data. Contact Details

VEKA. Air handling units. Lüftungsgeräte. Air handling units

Zehnder ComfoWell 220

Jet filter unit. Jetfilteranlage Typ

Produzierendes Gewerbe Industrial production

Photo: konradmuranski-fotolia.com

Retraktionssystem Frankfurt Frankfurt Retraction System

Dokumentation. Schnellentlüftungsventile - Typ SE..., SV..., SE... ESG, SE... K ES -

Honeywell AG Hardhofweg. D Mosbach MU1H-1220GE23 R1001

I-Energieversorgung I-Power Supply

Vacuum. Vakuum. Modul 3 Module 3 155

Attenuator and Distribution System Zehnder ComfoWell 220

Circular Knitting Machine

LAS. für Laserrauch. Lufttechnik für Umwelt- und Gesundheitsschutz. Reine Luft, starke Leistung.

Ultra Cleaner Kompaktabsaugung Typ UC compact

X-ROW G X-ROW 60 G X-ROW 80 G X-ROW 100 G X-ROW 120 G X-ROW 170 G X-ROW 230 G X-ROW 300 G X-ROW 370 G X-ROW 460 G. Kompressoren. 50 Hz Auswahldiagramm

EEX Kundeninformation

Video Line Array Highest Resolution CCTV

Hazards and measures against hazards by implementation of safe pneumatic circuits

Luftfördermenge / Air flow: (m³/h)

Counterflow Heat Recovery Fan

Serviceinformation Nr. 05/10

FRS. Filter unit. Filtereinheit Typ

UFPR. Extraction table with fan. Absaugtisch mit Ventilator Typ

Vacuum. Vakuum C-VLR 0,01 0, Auswahldaten Klauen-Vakuumpumpen Reihe C-VLR

Quadt Kunststoffapparatebau GmbH

Flexible Leiterplatten / flexible PCB:

Aufbau eines IT-Servicekataloges am Fallbeispiel einer Schweizer Bank

Innenbelüftete Synchron-Generatoren

Dach-Filterlüfter und Entlüftung Roof Filter Fan and Exhaust Filter DVL / DVE

Individuelle Lösungen für die Luftfiltrierung Elektrostatische und mechanische Einzel- und Modulfilter. Die Luft ist rein

Westenberg Wind Tunnels

Connecting bend 90 connecting bend parts that serve as a connection between the hydraulic separator and the compact manifold.

Technical Documentation and Operation Manual. Kühlgehäuse der Pyrometerserie Metis Cooling jacket for pyrometer series Metis (KG10-00)

Stellvertretenden Genehmiger verwalten. Tipps & Tricks

miditech 4merge 4-fach MIDI Merger mit :

Bleifreie Bauteile bei Diotec Lead Free Products at Diotec

Austausch Saugschlauch am CUBE-Dieseltank

PNEUMATISCHE PUMPEN PNEUMATIC PUMPS

ABSAUG / FILTER / UMWELTSCHUTZ // TECHNOLOGIE

P-07. Pneumatically operated valves 3/2-way, G 1/4, 1580 Nl/min (1.606 Cv) Technical data for series

HF13-Programm HF13 Programme

Attenuator and Distribution System Zehnder ComfoWell 320

MOBIL-POWER UNIT 160. Die Vorteile. Produktkatalog: Filteranlagen / Abscheider Abschnitt: 03 Seite: 47 Revision: 03/2012

Proxmox Mail Gateway Spam Quarantäne Benutzerhandbuch

Output Choke Installation Instructions

Baureihe 260 LAS 260 HD FK

GEA Heat Exchangers An/To: Von/From: Date/Datum. Dirk Graichen Product Manager BPHE

Technische Daten. Technical data. Radialventilatoren Baureihe RE..P / RG..S / RD..S. Centrifugal fans Series RE..P / RG..S / RD..S

Hydraulische Bremsen

Therefore the respective option of the password-protected menu ("UPDATE TUBE DATA BASE") has to be selected:

Attenuator and Distribution System Zehnder ComfoWell 520

CarMedia. Bedienungsanleitung Instruction manual. AC-Services Albert-Schweitzer-Str Hockenheim

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

Wartungseinheiten Spezial Serie FRL Special Series

Erste Glasbläserbrille, die als Arbeitsschutzbrille. The first glassblower s glasses which can be referred to as safety glasses.

Oil / Air cooler ASA-TT 11 12V/24V DC Öl /Luftkühler ASA-TT 11 12V/24V DC

Dedusting pellets. compact edition

Produktinformation _182PNdeen

U 4814 U 4818 U 4851 U 4852 U 4854 U 4855 U 4856

GE /2015-D KARL STORZ UNIMAT 30. Die Absaugung in der Gastroenterologie

HR mural. Radialventilatoren in TAC Technologie

Dampfzustandsregelventil DZE Steam conditioning valve DZE

Active into the future Effizienz, Performance & Nachhaltigkeit!

krones Linadry Der Behältertrockner

Datenblatt Seitenkanalgebläse Data sheet side channel blowers

Werbemittel-Spezifikationen

Simulation und Auslegung von Systemen für die Endoskopdesinfektion. Dipl.Ing. Jens Waldmann Olympus Winter & Ibe GmbH

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Funktionsprinzip Operating principle

Datenblatt Seitenkanalgebläse Data sheet side channel blowers

Effiziente IT- Kühllösungen Die front to back Luftführung im Server. Luftführung im Server

Datenblatt Flüssigkeitsringpumpe Data sheet liquidring pump

Hochdruckverdichter für kalt verflüssigte Gase, Gase und Flüssigkeiten. High Pressure Compressors for Cold Liquid Gases, Gases and Liquids

QS solutions GmbH. präsentiert das Zusammenspiel von. Ihr Partner im Relationship Management

TBH ABSAUG- UND FILTERANLAGE GL-30

Weltweit Partner der Holzindustrie Worldwide partner for the lumber industry

Transkript:

ULT JUMBO Filtertrolley 2.0 MED

Technical Documentation for Extraction and Filter Unit Type Series Jumbo MED During medical applications like laser surgery, electrocautery and others hazardous surgical plume, viruses and bacterias in the form of dust, floating particles, gases and fumes are generated. This smoke can be a respiratory irritant to the surgical team and to the patients, but more it can be a source of airborne infection. To minimize the risk of infectious particulates and also according to regulations of air purification at the workplace it is recommended that a smoke evacuator is used. The smoke evacuator ULT JUMBO Filtertrolley is especially designed for these tasks. The optional recirculation ventilation helps to reduce energy costs. The simple and application-oriented, partially even individual, solutions result from longtime experience in theory and practice and a multitude of different application cases. Advantages of the JUMBO Filtertrolley Ultra quiet compact design high performance fans with low energy consumption user-friendly and cost-effective easy operation, maintenance and filter replacement Fields of Application Medical laser surgery and electrocautery, Laboratories Sterilization rooms, Patient s awakening rooms Anaestesthesia rooms, Dentist s surgery Possible Connections Extraction hoods and tubes Filter Technology prefilter carton F 5 disposal is free from contamination HEPA filter H 13 Activated carbon filter - 2 -

Technical Documentation for Extraction and Filter Unit Type Series Jumbo MED 1. inlet stub 2. filter cartridge 3. air outlet 4. motor / fan 5. flow rate controller 6. power switch 7. loaded filter indicator 2 1 7 6 5 233 3 4 Functional principle: A special fan (4) with a large capacity of spare pressure creates an air flow adapted to the respective application at the clean air section of the filter cartridge (2). An optional flow rate controller is available. The hazardous air is reliably extracted (1) and cleaned. Because of the high purity of the filtered air it can be supplied back to the working area (3), thus, reducing energy costs. The different filters are combined in one filter cartridge and can be replaced singularly. The filter is recyclable. - 3 -

Technical Documentation for Extraction and Filter Unit Type Series Jumbo MED Specification / Fan Graph Type Series Parameters Unit Jumbo max. flow rate m³/h 170 max. vacuum Pa 2.800 nominal capacity m³/h at Pa 80 / 1.400 nominal motor power kw 0,15 nominal voltage V 230 nominal currency A 0,95 frequency Hz 50 type of protection IP 54 noise level at 50% db(a) 45 noise level at 100% db(a) 49 weight kg 18 flow rate controller optional loaded filter indicator optional inlet stub mm 1 x Ø50 or 1 x Ø75 or 2 x Ø50 air outlet 2 x adjustable nozzles 3000 Type series Jumbo Filtertrolley 2.0 differential pressure p (Pa) 2500 2000 1500 1000 500 0 40 80 120 160 200 3 flow rate V (m /h) - 4 -

Technical Documentation for Extraction and Filter Unit Type Series Jumbo MED Dimensions Filtertrolley 2.0 MED alternatively: 1 x Ø 50mm 1 x Ø 75mm 2 x Ø 50mm max. 850 mm 530 mm 450 mm 340 mm - 5 -

Technical Documentation for Extraction and Filter Unit Type Series Jumbo MED Spare parts Filtertrolley 2.0 MED suction flange loaded filter indicator power switch stepless adjustable flow rate controller Prefilter carton F5 air outlet fan HEPA filter H13 Activated carton wheel Brevo B.V. Dokwerkerstraat 3 2984 BJ Ridderkerk Telefoon 0180-417344, Fax 0180-411563 Email : info@brevo.nl, Web : www.flexibeleslangen.nl - 6 -

ULT JUMBO Filtertrolley 2.0 MED

Technische Dokumentation Absaug- und Filtergerät Serie Jumbo MED Medizinische Rauchgasabsaugung Bei HF-Chirurgie und medizinischen Laseranwendungen entstehen durch Vaporisationseffekte Raugaspartikel. Diese Abbrandprodukte mit einer Partikelgröße von 0,1 bis 5 µ gelangen als Laserrauch in die Atemluft und gefährden Arzt und Patient. Eine effektive Absaugung am Entstehungsort und eine zuverlässige Filterung vermindern das Risiko einer viren- und Bakterienverbreitung und reduzieren die Geruchsbelästigung durch verbranntes Gewebe. Berufsgenossenschaften und Arbeitsschutzbestimmungen schreiben den Einsatz von Absaugsystemen vor. Mundschutz und zentrale Raumabsaugung sind kein ausreichender Schutz. Der JUMBO MED ermöglicht die direkte Erfassung der Pyrolyseprodukte am Entstehungsort und stellt damit die effektivste Methode dar, gefährliche Gase, Dämpfe und Partikel sowie infektiöse Aerosole zu beseitigen. Vorzüge des JUMBO MED Filtertrolleys: geringer Schallpegel kompakter Aufbau Hochleistungsventilatoren mit geringem Energieverbrauch recycelbare Filter mit hoher Kapazität einfache Bedienung, Wartung und Filterwechsel Einsatzbereiche: Medizinische Rauchgasabsaugung für Laseranwendungen im Bereich Ästhetik, Chirurgie, Ophthalmologie und HF-Chirurgie. Tierkliniken, Zahnarztpraxen, Labor und Anästhesiearbeitsplätzen. Anschlussmöglichkeiten: Absaugarme, Absaugkabinette, Absaughauben, Filtertechnik: Vorfilter Karton F 5 kontaminationsfreie Entsorgung HEPA Filter H 13 Aktivkohlefilter - 2 -

Technische Dokumentation Absaug- und Filtergerät Serie Jumbo MED 1. Ansaugstutzen 2. Filterkassette 3. Luftauslass 4. Volumenstromregelung 5. Netzschalter 6. Filterbelegungsanzeige 2 1 7 6 5 2333 4 Funktionsprinzip: Ein Spezialventilator (4) mit hoher Druckreserve erzeugt auf der Reinluftseite der Filterkassette (2) einen der Anwendung entsprechenden regelbaren Volumenstrom. Die schadstoffbelastete Luft wird zuverlässig abgesaugt (1) und gereinigt. Die gefilterte Luft kann dem Arbeitsraum durch die hochgradige Reinigung wieder zugeführt werden (3). Somit können Energiekosten gespart werden. Die unterschiedlichen Filter sind in einer Kassette kombiniert und einzeln wechselbar. Der Filter ist recycelgerecht aufgebaut. - 3 -

Technische Dokumentation Absaug- und Filtergerät Serie Jumbo MED Technische Daten / Ventilatorkurve: Parameter Baureihe Einheit Filtertrolley 2.0 max. Volumenstrom m³/h 170 max. Unterdruck Pa 2.800 Nennleistung m³/h bei Pa 80 / 1.400 Motor-Nennleistung kw 0,15 Nennspannung V 230 Nennstrom A 0,95 Frequenz Hz 50 Schutzart IP 54 Schallpegel bei 50% db(a) 45 Schallpegel bei 100% db(a) 49 Gewicht kg 18 Volumenstromregler Filterbelegungsanzeige optional optional Ansaugstutzen mm 1 x Ø50 o. 1 x Ø75 o. 2 x Ø50 Abluftführung 2 x Ausblasdüse einstellbar - 4 -

Technische Dokumentation Absaug- und Filtergerät Serie Jumbo MED Maße Filtertrolley 2.0 MED Wahlweise : 1 x Ø 50mm 1 x Ø 75mm 2 x Ø 50mm max. 850 mm 530 mm 340 mm 450 mm - 5 -

Technische Dokumentation Absaug- und Filtergerät Serie Jumbo MED Ersatzteile Filtertrolley 2.0 MED Ansaugstutzen Luftverteilungssplatt Spannverschluss Filterbelegungs- Anzeige Netzschalter Stufenlose Volumenstromregelung Luftauslass Ventilator Rad Brevo B.V. Dokwerkerstraat 3 2984 BJ Ridderkerk Telefoon 0180-417344, Fax 0180-411563 Email : info@brevo.nl, Web : www.flexibeleslangen.nl - 6 -