Christ Water Technology Group 1 / 10.10.2002 / Schmitt G.
THREE DIVISIONS OF BWT GROUP BWT AG Christ Water Technology Group Aqua Ecolife Technologies FuMA-Tech (Industrial & Municipal Division) (Household & Homes Division) (Fuel Cell Division) 2 / 10.10.2002 / Schmitt G.
KEY FIGURES OF BWT GROUP 1999 2000 2001 Turnover Mio 245.3 399.0 419.5 Net Profit Mio 9.3 15.4 15.2 Issued Shares 1,000s 16,500 16,500 17,833.5 Employees 1,839 2,510 2,511 3 / 10.10.2002 / Schmitt G.
CWT GROUP 4 / 10.10.2002 / Schmitt G.
SALES PER BUSINESS UNIT 2000 8% 5% 2002e 8% 12% 22% 10% 49% 17% 20% 18% 11% Semiconductor Power Generation Pharma & Life Sciences Food & Beverage Industrial Process & Waste Municipal Drinking & Sewage 13% 11% 6% 35% 2001 20% 20% 16% 5 / 10.10.2002 / Schmitt G.
COMPETENCE CENTERS Pharma & Life Sciences Power Generation Semiconductor Industrial Process & Waste Water Food & Beverage Municipal Drinking & Sewage Water Christ GmbH, Stuttgart Germany Christ-Kennicott Water Technology Ltd, Wolverhampton UK Christ AG, Aesch Switzerland Goema GmbH, Vaihingen Germany Van der Molen GmbH, Kissing Germany Aqua Engineering GmbH, Mondsee Austria 6 / 10.10.2002 / Schmitt G.
Pharmaceutical industry Life-science Due to their many years of experience and the know-how of their engineers, CHRIST GmbH has become a world-wide specialist for specific, technically demanding solutions in the following lines: 7 / 10.10.2002 / Schmitt G.
Water for the pharmaceutical industry Water for the pharmaceutical industry 8 / 10.10.2002 / Schmitt G. CHRIST GmbH plans, manufactures and installs customized system solutions from a single source. Made in Germany
Europe 9 / 10.10.2002 / Schmitt G.
Water: most important raw material in the pharmaceutical industry Drinking Water Purified Water WFI (Water for Injection) 10 / 10.10.2002 / Schmitt G.
Purified Water, limits values Parameter Ph. Eur. USP TOC [ppb C] 500 500 Conductivity [ 20 C µs/cm ] 4.3 - Conductivity [ 25 C µs/cm ] - 1.3 Nitrate (NO 3 ) [ ppm ] 0.2 - Heavy metals [ ppm as Pb ] 0.1 - Microbial contamination [ CFU/ml ] 100 100 11 / 10.10.2002 / Schmitt G.
WFI / HPW, limits values Parameter Ph. Eur. USP TOC [ppb C] 500 500 Conductivity [ 20 C µs/cm ] 1.1 - Conductivity [ 25 C µs/cm ] - 1.3 Nitrate (NO 3 ) [ ppm ] 0.2 - Heavy metals [ ppm as Pb ] 0.1 - Microbial contamination [ CFU/ml ] 10 10 Endotoxine units [ EU/ml] 0.25 0.25 12 / 10.10.2002 / Schmitt G.
FDA required trending system 13 / 10.10.2002 / Schmitt G.
Processes Purified water 14 / 10.10.2002 / Schmitt G.
Ionexchanger system AUTOSTIL conventional cation- / anion ionexchanger 15 / 10.10.2002 / Schmitt G.
Ionexchanger system e.g. Conductivity TOC Germ count < 1 µs/cm > 500 ppb > 100 cfu / ml 16 / 10.10.2002 / Schmitt G.
Ionexchanger system e.g. Conductivity TOC Germ count < 1 µs/cm > 500 ppb > 100 cfu / ml 17 / 10.10.2002 / Schmitt G.
Reverse osmosis OSMOSTIL double pass reverse osmosis 18 / 10.10.2002 / Schmitt G.
Reverse osmosis e.g. Conductivity TOC Germ count ~ 1 µs/cm < 50 ppb < 10 cfu / 100 ml Caustic soda addition RO pass 1 RO pass 2 19 / 10.10.2002 / Schmitt G.
Reverse osmosis e.g. Conductivity TOC Germ count ~ 1 µs/cm < 50 ppb < 10 cfu / 100 ml Caustic soda addition RO pass 1 RO pass 2 20 / 10.10.2002 / Schmitt G.
Reverse osmosis / Electrodeionisation OSMOTRON latest technique to produce purified water acc. to USP and Europ. Pharmacop. 21 / 10.10.2002 / Schmitt G.
Reverse osmosis / Electrodeionisation e.g. Conductivity TOC Germ count < 0.1 µs/cm < 50 ppb < 10 cfu / 100 ml Reverse osmosis Electrodeionisation 22 / 10.10.2002 / Schmitt G.
Reverse osmosis / Electrodeionisation e.g. Conductivity TOC Germ count < 0.1 µs/cm < 50 ppb < 10 cfu / 100 ml Reverse osmosis Electrodeionisation 23 / 10.10.2002 / Schmitt G.
Electrodeionisation What is Electrodeionisation? 24 / 10.10.2002 / Schmitt G.
CHRIST SEPTRON 25 / 10.10.2002 / Schmitt G.
Modular Designed Systems Capacity 140 l/hr - 5.000 l/hr Brand: Septron Line Osmotron - PH Osmotron - Inject Select technique Loopo Tested Pre-qualified Plug and Play No assembling on site 26 / 10.10.2002 / Schmitt G.
Septron Line The best in class SEPTRON Line purest water The small alternative to Osmotron CHRIST solution for smaller applications (140/400 l/h) Purified Water 27 / 10.10.2002 / Schmitt G.
OSMOTRON - PH Capacity 500 l/hr - 5000 l/hr Water treatment system for the production of Pruified Water in accordance with USP GAMP and cgmp conditions Osmotron - a compact and extremely safe alternative to conventional single units 28 / 10.10.2002 / Schmitt G.
OSMOTRON - PH Plug and Play units 29 / 10.10.2002 / Schmitt G.
OSMOTRON - Inject / Select Capacity 500 l/hr - 5000 l/hr Water treatment system for the production of HPW / WFI in accordance with USP / EP GAMP and cgmp conditions 30 / 10.10.2002 / Schmitt G.
31 / 10.10.2002 / Schmitt G.
LOOPO Plug and play system for disinfection / distribution / monitoring Skid mounted and compact Pre- assembled Pre-wired Ready for connection 32 / 10.10.2002 / Schmitt G.
LOOPO Plug and Play units 33 / 10.10.2002 / Schmitt G.
CHRIST solutions to meet your requirements Preparation Water treatment systems Installation Qualification Validation Service Represented by partner companies throughout the world 34 / 10.10.2002 / Schmitt G.
www.christ-wasser.de
www.christ-wasser.de