Installation and Removal Instructions for Series NRX Cassette Cell Switch

Ähnliche Dokumente
Montageanweisung für Series NRX Positionsmeldeschalter

Arbeits-und Montageanweisung für NRX Positionsmeldeschalter

Montageanweisung für Series NRX Rückseitige Hauptanschlüsse

Bedienungs- und Montageanweisung für Türverriegelung

Installation and removal instructions for Series NRX fixed breaker mounting feet

Installation/removal instructions for Series NRX drawout cassette primary adapters

Installation and Removal Instructions for Series NRX Front Connect Adapters

Installation and Removal Instructions for Series NRX Drawout Cassette Primary IP20 Safety Shutters

Installation and Removal Instructions for Series NRX Pushbutton Cover Kit

Series NRX drawout circuit breaker and cassette rejection interlocks

Montageanweisung für Series NRX Schaltspielzähler

Installation and Removal Instructions for Series NRX Rating Plug

Montageanweisung für NRX Ronis Verriegelung Sicheres AUS

Installation Instructions for Series NRX Communication Adapter Modules

Installation and Operation Instructions for Lev-In Door Interlock

Montageanweisung für Series NRX CES Verriegelung Sicheres AUS

Front-mounted standard terminal kits on IZM low voltage fixed circuit breakers and cassettes

Montageanweisungen für Schaltspielzähler

Installation/Removal Instructions for Series NRX Pushbutton Cover Kit

Installation/removal instructions for Series NRX drawout cassette primary IP20 safety shutters

Zeitverzögerungsmodul für Eaton Leistungsschalter

Instruction Leaflet IL E Montageanweisung für Series NRX Hilfsschalter

Montageanweisung für Series NRX Mechanische 3-Wege Verriegelung für Ausfahrtechnik

Montageanweisung für Series NRX Mechanische 2-Wege Verriegelung für Ausfahrtechnik

Mechanische Verriegelung über zwei Leistungsschalter, Festeinbau IZMX- MIL2C-F

Montageanweisung für Series NRX Ausgelöstmelder

Installation/removal instructions for Series NRX pushbutton cover kit

Installation and Removal Instructions for Series NRX CES Interlock Kit

ALL1688PC. Benutzerhandbuch. Passiver Powerline Verbindung (Home Plug Gerät) Phasenkoppler (Hutschienen Version)

Montageanweisung für Serie NRX Kassettenverriegelung

BRUUDT Kennzeichenhalter für die Honda NC750X ab 2016 BRUUDT Tail Tidy for the Honda NC750X 2016 and onwards.

TABLE OF CONTENTS STYLE 3293 PRODUCT NAME OPERATING INSTRUCTIONS

Montageanweisung für Serie NRX Mechanische 2-Wege Verriegelung für Ausfahrtechnik

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions

DMS für besondere Anwendungen - Hochtemperatur-DMS

Time Delay Undervoltage Module for use with Undervoltage Release in Eaton Circuit Breakers

Montageanweisung für Serie NRX Mechanische 3-Wege Verriegelung für Ausfahrtechnik

BRUUDT Kennzeichenhalter für die Kawasaki Z800 BRUUDT Tail Tidy fort the Kawasaki Z800

PoE Kit Mounting Instructions SG/XG 210/230/310/330/430/450

Deutsch. English. Eine sichere Gerätefunktion ist nur mit zertifizierten Komponenten gewährleistet!

Outdoor-Tasche. Operating Instructions Bedienungsanleitung GB D

Montageanweisung Mounting Instructions NGC NGC NGC

Instructions for Series NRX Neutral Current Sensor Type NF

Fitting Instructions for DG0017 BK Downpipe Grille BMW F800GT 2013

Electrical testing of Bosch common rail piezo injectors

I. Benötigtes Werkzeug: I. Required tools: Installation manual / Montageanleitung ODU2 MTP plug n play version. Content of Assembly Instruction

Einbausatz Hub montieren

Electrical testing of Bosch common rail Injectors

Um die Originalschrauben an den Federbeinen zu demontieren, bedarf es eines Yamaha Spezialwerkzeugs: Torxnuss T40 mit Bohrung

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Accessoires

i500 Sicherheitsmodul I5MASA000 I5MASA000 safety module Montageanleitung Mounting Instructions

p^db=`oj===pìééçêíáåñçêã~íáçå=

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

BRUUDT Kennzeichenhalter für die Yamaha MT-03 und R3 BRUUDT Tail Tidy for the Yamaha MT-03 and R3

Snap-in switch for switches PSE, MSM and MCS 30

SnagIt Movable Type Output By TechSmith Corporation

Wie Programm Neighborhood Agent mit Secure Gateway konfigurieren. von Stefan Müri

CELSIUS M / R / V Rack Kit. Mounting Instructions

SnagIt LiveJournal Output By TechSmith Corporation

Thule Excellence XT Instructions

Technical Bulletin. Important! Condition. Service. 1 of 3. Trunk Lid Harness, Installing Repair Harness. Please give copies to all your VW Technicians

Einbauanleitung / Installation Instructions Kit CM44xR

MSS /S Revision: 03. Motorschutz / Engine Guard ACHTUNG / ATTENTION. Mounting Instructions. Montagehinweise

JX3-PS1. Installationsanleitung. Version Lieferumfang

Electrical tests on Bosch unit injectors

C1+C2: Online-Umfrage Ihre Analytics Architektur heute und morgen?

Einbau- und Montageanleitung Tankabdeckung TopCover Seite 2-4 Assembly and installation instructions Tank Cover - TopCover Page 5-7

Montageanweisung Mounting Instructions

Motorschutzbügel/ Engine guard

mobilcom-debitel SmartHome Schnell-Start-Anleitung Quick Start Guide

How-To-Do. Hardware Configuration of the CC03 via SIMATIC Manager from Siemens

Wandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply

Aufbaudose mit Schalter Spacing box with switch. Montageanleitung mounting instructions

Ex-Barriere für Diagnoseeinheit SITRANS DA400 / Ex-barrier for diagnostics unit SITRANS DA400 7MJ2010-1AA 0032

Montageanweisung Mounting Instructions

Montageanweisungen für Series NRX Unterspannungsauslöser, Arbeitsstromauslöser und Meldeschalter Ausgelöst

Open-Source-Software core_cm3.h

Hypex d.o.o. Alpska cesta 43, 4248 Lesce Slovenija Tel: +386 (0) Fax: +386 (0)

V Montageanleitung für Aufbewahrungssystem-Module. Organized Storage Modules Assembly Manual. Gebrauchsanweisung. Operating Instructions

Disclaimer SAP SE or an SAP affiliate company. All rights reserved. Public

Montageanweisung für Series NRX Einschaltmagnet, Meldeschalter Einschaltbereit und Motorantrieb

Electrical testing of Bosch common rail solenoid valve (MV) injectors

Installation manual / Montageanleitung WBC2 splice patch with Fibertray Spleissung/Rangierung mit Fibertray

Ladeluftkühler / Intercooler

QuickStart. Montageanweisung QuickStart (Seite 2-3) QuickStart Assembly Instructions (Page 4-5) Achtung:

Release Notes BRICKware Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Quad-Parts Accessoires

BRUUDT Kennzeichenhalter für die Yamaha MT-07 BRUUDT Tail Tidy for the Yamaha MT-07

Standard Power Integrated Module

Qube Ofenreling HALTERUNGSSET QUBE-HSR1 / QUBE-HSR2. MONTAGEANWEISUNG Deutsch. Passend für folgende Modelle: QUBE-090 QUBE-105 QUBE-120 QUBE-150

IZMX Installation und Entfernen des Ronis-Schloss-Bausatzes

Telefon: +49 (0) 5251 / Telefax: +49 (0) 5251 /

Open-Source-Software

Word-CRM-Upload-Button. User manual

Qualitätsmanagement-Handbuch Serviceinformation: _Serviceinformation H0201_1_Batterietrennschalter.doc Formblatt. ÜS;Linearlifte AL1

BMW F 800 GS Motorschutzbügel Nr.: schwarz Nr.: titan

4 Season Track Assembly Instructions (Addendum)

Transkript:

Installation and Removal Instructions for Series NRX Cassette Cell Switch Instructions apply to: Effective April 2014 Supercedes August 2013 Series NRX Series NRX, Type RF Frame IEC, IZMX40 WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON THE EQUIPMENT. (2) ALWAYS DE-ENERGIZE PRIMARY AND SECONDARY CIRCUITS IF A CIRCUIT BREAKER CANT BE REMOVED TO A SAFE WORK LOCATION. (3) DRAWOUT CIRCUIT BREAKERS SHOULD BE LEVERED (RACKED) OUT TO THE DISCONNECT POSITION. (4) ALL CIRCUIT BREAKERS SHOULD BE SWITCHED TO THE OFF POSITION AND MECHANISM SPRINGS DISCHARGED. FAILURE TO FOLLOW THESE STEPS FOR ALL PROCEDURES DESCRIBED IN THIS INSTRUCTION LEAFLET COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY DAMAGE. WARNING THE INSTRUCTIONS CONTAINED IN THIS IL AND ON PRODUCT LABELS HAVE TO BE FOLLOWED. OBSERVE THE FIVE SAFETY RULES: DISCONNECTING ENSURE THAT DEVICES CANT BE ACCIDENTALLY RESTARTED VERIFY ISOLATION FROM THE SUPPLY EARTHING AND SHORT-CIRCUITING COVERING OR PROVIDING BARRIERS TO ADJACENT LIVE PARTS DISCONNECT THE EQUIPMENT FROM THE SUPPLY. USE ONLY AUTHORIZED SPARE PARTS IN THE REPAIR OF THE EQUIPMENT. THE SPECIFIED MAINTENAE INTERVALS AS WELL AS THE INSTRUCTIONS FOR REPAIR AND EXCHANGE MUST BE STRICTLY ADHERED TO PREVENT INJURY TO PERSONNEL AND DAMAGE TO THE SWITCHBOARD.

Effective April 2014 Installation and Removal Instructions for Series NRX Cassette Cell Switch Section 1: General Information The cassette cell switch is a compartment position switch for drawout circuit breakers that provides remote indication of breaker position (disconnect, test, connect). It is comprised of a cassette mounted switch assembly and an actuator. The switch assembly consists of 3 FORM C switches, which are operated by a common actuator. The diagrams (Figures 2 and 3) illustrate the switch contact positions when the breaker is in a specific position within the cassette. As the breaker is levered in or out from one position to another the appropriate switch changes state as a result of contact with the breaker mounted actuator. Kit Parts Identification Refer to Figure 1 for visual identification of the parts listed below: (A) Cell switch assembly (1) (B) Cell switch actuator (1) and M3 x 5mm mounting screws (2) (screws not shown) (C) (Fixed) secondary terminal blocks (5) (D) Terminal block mounting bracket (1) (E) 12mm self-threading TORX head type mounting screws (3) (not shown) C1 C2 C3 T1 T2 T3 Breaker in Test Position Breaker in Connected Position COM COM COM COM COM COM CONNECTED TEST CONNECTED DISCONNECT TEST DISCONNECT Secondary terminal block (C) Cell switch assembly (A) D1 D2 D3 Breaker in Disconnected Position COM COM COM CONNECTED TEST DISCONNECT Actuator (B) Terminal block mounting bracket (D) Figure 3. Cell Switch Diagrams COM - common wire (BLACK) - normally open (RED) - normally closed (BLUE) Figure 1. Contents of Kit Signaling switch for: Contacts Circuit-breaker position Disconnect Position Test Position Connected Position Disconnect Position COM Test Position COM Connected Position COM COM - Common Wire (BLACK) - Normally Open (RED) - Normally Closed (BLUE) Contact Open Contact Closed Figure 2. Circuit Breaker Position and Contacts 2

Installation and Removal Instructions for Series NRX Cassette Cell Switch Instruction Leaflet IL01301054E Effective April 2014 Section 2: Cell Switch Actuator Orientation The cell switch assembly is mounted to the inside of the cassette side sheet on either the left or right side. The kit comes preassembled for installation to the left side of the cassette. If mounting to the right side sheet is preferred the actuator can be changed as follows. Step 1: Remove the two M3 screw and the actuator from the assembly. LEFT SIDE MOUNTING (DEFAULT) ACTUATOR Section 3: Installation of Cassette Cell Switch Proceed with the following 5 steps. Note: The circuit breaker must be removed from its cassette prior to starting the installation process. Step 1: The cell switch assembly (A) is mounted on the inside of the cassette s side sheet. Three screws are used to mount the assembly and they are supplied with the cell switch kit. Secondary terminal blocks mounted to arc hood DIN rail Top mounting hole M3 SCREWS Figure 4. Step SECTION 1 2-STEP 1 IMAGE Step 2: Move the actuator to the opposite side of the assembly and ensure that the arrow molded on the actuator is pointing to the shorter side of the cases, this is the front. Reinstall the screw closest to the arrow first, followed by the one at the end of the lever. Fully seat the SECTION 2-STEP 2 IMAGE screws. Do not over tighten. RIGHT SIDE MOUNTING Mounting holes Inside of cassette left side sheet ACTUATOR ARROW Figure 5. Step 2 ACTUATOR ARROW Step 3: Slowly slide the actuator through its full range to ensure free motion and that it returns fully. Step 4: Move the cell switch wires from the wire retention slot on the left side of the terminal bracket over to the slot on the right side. This helps keep the wires tight against the cassette side sheet SECTION 2-STEP 2 IMAGE Figure 7. Steps 1-3 RIGHT SIDE MOUNTING Step 2: Position the cell switch assembly (A) on the inside of the cassette s side sheet so the three mounting holes match up with the switch assembly mounting holes. Confirm the arrow at the top of the cell switch cases are pointing up and the arrow on the actuator is pointing toward the front of the cassette. Step 3: Insert the 12mm TORX head type mounting screw (E) supplied with the kit into the top mounting hole first. Next insert the remaining 12mm TORX head type mounting screws. Hand tighten to a maximum torque of 25 in. lbs. (2.8 Nm). Move the actuator front to back to ensure that the slider is free. Step 4: The terminal block mounting bracket (D) can be mounted on the secondary DIN rail next to the secondary terminal blocks mounted to the arc hood. (Figure 7). ROUTE WIRES THROUGH THIS RETENTION SLOT FOR LEFT SIDE MOUNTING ROUTE WIRES THROUGH THIS RETENTION SLOT FOR RIGHT SIDE MOUNTING Figure 6. Step 4 3

Effective April 2014 Installation and Removal Instructions for Series NRX Cassette Cell Switch Section 5: Recommended Wiring D1 T3 T1 C1 D2 D3 T2 C2 C3 Figure 8. Step 4 Step 5: The circuit breaker can now be put back into the cassette. Lever the breaker into and out of its three positions to ensure that cell switch assembly is operating smoothly. Note: Keep in mind that the indicator on the front of the circuit breaker must indicate that the breaker is in the DISCONNECT position to permit insertion of the breaker into its cassette. Wiring to the cell switch terminal block must be kept clear of the arc hood vents. Section 4: Removal of Cassette Cell Switch Remove the circuit breaker from its cassette and perform Steps 1 through 5 in reverse. Figure 9. Wire Label Description Wire Color D1 Disconnect Red D2 Disconnect COM Black D3 Disconnect Blue T1 Test Red T2 Test COM Black T3 Test Blue C1 Connect Red C2 Connect COM Black C3 Connect Blue Table 1. Secondary Terminal Points 4

Installation and Removal Instructions for Series NRX Cassette Cell Switch Instruction Leaflet IL01301054E Effective April 2014 Notes: 5

Effective April 2014 Installation and Removal Instructions for Series NRX Cassette Cell Switch Disclaimer of warranties and limitation of liability The information, recommendations, descriptions, and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment, and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, ILUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL T BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability, or otherwise for any special, indirect, incidental, or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations, and descriptions contained herein. The information contained in this manual is subject to change without notice. Eaton 1000 Eaton Boulevard Cleveland OH, 44122 United States 877-ETN-CARE (877-386-2273) Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. IL01301054EH03 / TBG0001100 April 2014 Eaton is a registered Trademark. All other Trademarks are property of their respective owners. 6

Gültig April 2014 Ersetz August 2013 Montageanweisung für Series NRX Positionsmeldeschalter Die Montageanweisung ist für folgende Baugrößen gültig: Serie NRX Series NRX, Type RF Frame IEC, IZMX40 n WARNUNG (1) DIE INSTANDHALTUNG DARF NUR DURCH ENTSPRECHEND ELEKTRONTECHNISCH QUALIFIZIERTES PERSONAL ERFOLGEN. (2) VOR BEGINN DER ARBEITEN MUSS DER SPANNUNGSFREIE ZUSTAND DER SCHALTANLAGE HERGESTELLT UND WÄHREND DER ARBEITEN SICHERGESTELLT SEIN. (3) SCHALTER IN AUSFAHRTECHNIK MÜSSEN IN TRENNSTELLUNG GEFAHREN WERDEN. (4) DIE SCHALTER SIND AUF AUS ZU STELLEN UND DER FEDERSPEICHER IST ZU ENTSPANNEN. BEIM BETRIEB ELEKTRISCHER GERÄTE STEHEN ZWANGSLÄUFIG BESTIMMTE TEILE DIESER GERÄTE UNTER GEFÄHRLICHER SPANNUNG. UNSACHGEMÄSSER UMGANG MIT DIESEN GERÄTEN KANN DESHALB ZU TOD ODER SCHWEREN KÖRPERVERLETZUNGEN SOWIE ERHEBLICHEN SACHSCHÄDEN FÜHREN. n WARNUNG BEACHTEN SIE BEI INSTANDHALTUNGSMASSNAHMEN AN DIESEM GERÄT ALLE IN DIESER AWA UND AUF DEM PRODUKT SELBST AUFGEFÜHRTEN HINWEISE. DIE FÜNF SICHERHEITSREGELN SIND EINZUHALTEN FREISCHALTEN GEGEN WIEDEREINSCHALTEN SICHERN SPANNUNGSFREIHEIT FESTSTELLEN ERDEN UND KURZSCHLIESSEN BENACHBARTE, UNTER SPANNUNG STEHENDE TEILE ABDECKEN ODER ABSCHRANKEN DAS GERÄT IST VOM NETZ ZU TRENNEN. ES DÜRFEN NUR VOM HERSTELLER ZUGELASSENE ERSATZTEILE VERWENDET WERDEN. DIE VORGESCHRIEBENEN WARTUNGSINTERVALLE SOWIE DIE ANWEISUNGEN FÜR REPARATUR UND AUSTAUSCH SIND UNBEDINGT EINZUHALTEN, UM SCHÄDEN AN PERSONEN UND ANLAGEN ZU VERMEIDEN.

Gültig April 2014 Montageanweisung für Series NRX Positionsmeldeschalter Abschnitt 1: Allgemeine Informationen Jeder Positionsmeldeschalter besteht aus drei einpoligen Wechselschaltern welche von einem einfachen Auslöser betätigt werden. Abbildung 2 und 3 zeigen die Position der Kontakte in der jeweiligen Position des Schalters in der Kassette. Inhalt siehe Abbildung 1 (A) Positionsmeldeschalter (1) (B) Auslöser (1) und Montageschrauben M3 x 5 (2) (Schrauben nicht abgebildet) (C) Steuerleitungsanschlussblöcke (Festeinbau) (5) (D) Halterung für Steuerleitungsanschlussblöcke (1) (E) 12mm selbstschneidende TORX Schrauben (3) (nicht abgebildet) Steuerleitungsanschlussblock (C) Abbildung 1. Inhalt Positionsmeldeschalter (A) und Torx Schrauben (E) Auslöser (B) mit M3 Montageschrauben Halterung (D) C1 C2 C3 T1 T2 T3 D1 D2 D3 Schalter eingefahren COM COM COM Schalter in Teststellung COM COM COM Schalter in Trennstellung COM COM COM COM - common wire (schwarz) - normally open (rot) - normally closed (blau) Schalter eingefahren Teststellung Trennstellung Schalter eingefahren Teststellung Trennstellung Schalter eingefahren Teststellung Trennstellung Abbildung 3. Kontakte Positionsmeldeschalter Signalisierung für: Kontakte Stellung Leistungsschalter Trennstellung Teststellung Schalter eingefahren Trennstellung COM Teststellung COM Schalter eingefahren COM COM - Common Wire (schwarz) - Normally Open (rot) - Normally Closed (blau) Kontakt offen Kontakt geschlossen Abbildung 2. Zustand Kontakte bei jeweiliger Leistungsschalterstellung 2

Montageanweisung für Series NRX Positionsmeldeschalter Instruction Leaflet IL01301054E Gültig April 2014 Abschnitt 2: Montageseite Die Positionsmeldeschalter-Einheit kann in der Kassette entweder rechts oder links am inneren Seitenblech montiert werden. Der Bausatz wird vormontiert für den linksseitigen Einbau geliefert. Wenn die Montage auf der rechten Seite bevorzugt wird, kann die Betätigungsvorrichtung wie folgt verändert werden: Schritt 1: Entfernen Sie die zwei M3-Schrauben und die Betätigungsvorrichtung von der Einheit. LINKSSEITIGER EINBAU (STANDARD) Abschnitt 3: Montage des Positionsmeldeschalters Enfternen Sie den Schalter aus der Kassette bevor Sie mit der Montage beginnen. Führen Sie die folgenden Schritte aus: Schritt 1: Der Positionsmeldeschalter (A) wird an der linken Innenwand der Kassette montiert. Dafür werden drei Schrauben benötigt. Diese sind Bestandteil des Montagesatzes. Steuerleitungsanschlüsse BETÄTIGUNGS- VORRICHTUNG DIN- Schiene M3-SCHRAUBEN Abbildung 4. Schritt 1 SECTION 2-STEP 1 IMAGE Schritt 2: Montieren Sie die Betätigungsvorrichtung der Einheit auf die gegenüberliegende Seite SECTION und stellen 2-STEP Sie 2 IMAGE sicher, dass der Pfeil der Betätigungsvorrichtung zur kürzeren Seite des Gehäuses zeigt. Bringen Sie die näher am Pfeil befindliche Schraube zuerst wieder an, und danach die am Ende des Hebels. RECHTSSEITIGER EINBAU obere Aufnahmebohrung SECTION 2-STEP 2 IMAGE Aufnahmebohrungen Abbildung 7. Schritts 1-3 RECHTSSEITIGER EINBAU linke Kassetteninnenseite PFEIL DER BETÄTIGUNGSVORRICHTUNG Abbildung 5. Schritt 2 PFEIL DER BETÄTIGUNGSVORRICHTUNG Schritt 3: Schieben Sie die Betätigungsvorrichtung langsam durch ihren ganzen Bewegungsbereich, um die freie Beweglichkeit und das selbständige rückfahren sicherzustellen. Schritt 4: Stecken Sie die Drähte des Positionsmeldeschalters von der Aussparung auf der linken Seite der Anschlussklemme in die gegenüberliegende Aussparung auf der rechten Seite. So werden die Drähte eng an der Seite der Kassette entlang geführt. Schritt 2: Positionieren Sie die Positionsmeldeschalter-Einheit (A) so auf der Innenseite des Seitenblechs der Kassette, dass sich die drei Bohrungen mit den Montagelöchern der Positionsmeldeschalter-Einheit decken. Prüfen Sie, dass der Pfeil oben auf der Positionsmeldeschalter- Einheit nach oben zeigt, und der Pfeil auf der Betätigungsvorrichtung zur Vorderseite der Kassette zeigt. Schritt 3: Schrauben Sie zuerst eine Torx Schraube (E) in die obere Aufnahmebohrung. Hand ziehen sie mit einem maximalen Drehmoment von 25 in-lbs. (2,8 Nm). Bewegen Sie den bremszylinder vorne nach hinten, damit der Regler ist frei. Schritt 4: Die Montagehalterung für die Reihenklemmen (D) kann auf die zweite DIN-Schiene neben den bereits vorhandenen Reihenklemmen aufgesteckt werden. (Abbildung 7). STECKEN SIE DIE DRÄHTE DURCH DIE AUSSPARUNG FÜR DIE LINKSSEITIGE MONTAGE STECKEN SIE DIE DRÄHTE DURCH DIE AUSSPARUNG FÜR DIE RECHTSSEITIGE MONTAGE Abbildung 6. Schritt 4 3

Gültig April 2014 Montageanweisung für Series NRX Positionsmeldeschalter Abschnitt 5: Empfohlene Verdrahtung D1 T3 T1 C1 D2 D3 T2 C2 C3 Abbildung 8. Schritt 4 Schritt 5: Der Leistungsschalter kann nun wieder in die Kassette gefahren werden. Fahren Sie den Schalter in alle drei Positionen, um sicher zu stellen, dass es nach der Montage des Positionsmeldeschalters keine Widerstände gibt. Anmerkung: Die Anzeige auf dem Schalter muss anzeigen, dass der Schalter in der DISCONNECT (Trennstellung) ist, damit der Schalter in die Kassette gefahren werden kann. Die Verdrahtung zum Reihenklemmblock darf nicht über den Lichtbogenöffnungen verlegt werden. Abschnitt 4: Entfernen des Positionsmeldeschalters Fahren Sie den Schalter aus der Kassette, lösen Sie die Montageschrauben und entnehmen Sie den Positionsmeldeschalter. Abbildung 9. Leitungsmarkierung Beschreibung Farbe der Leitung D1 Trennstellung Rot D2 Trennstellung COM Schwarz D3 Trennstellung Blau T1 Teststellung Rot T2 Teststellung COM Schwarz T3 Teststellung Blau C1 Eingefahren Rot C2 Eingefahren COM Schwarz C3 Eingefahren Blau Tabelle 1. Steuerleitungsmarkierungen 4

Montageanweisung für Series NRX Positionsmeldeschalter Instruction Leaflet IL01301054E Gültig April 2014 5

Gültig April 2014 Montageanweisung für Series NRX Positionsmeldeschalter Haftungsausschluss und Haftungsbeschränkungen Die Angaben, Empfehlungen, Beschreibungen und Sicherheitshinweise in diesem Dokument basieren auf Erfahrungswerten und Einschätzungen von Eaton Corporation ( Eaton ) und decken nicht alle Möglichkeiten ab. Wenn weitere Informationen benötigt werden, sollte ein Vertriebsbüro von Eaton kontaktiert werden. Der Verkauf des in diesem Dokument beschriebenen Produktes unterliegt den Bedingungen in den entsprechenden Geschäftsbedingungen von Eaton oder anderen vertraglichen Vereinbarungen zwischen Eaton und dem Käufer. ES GIBT KEINE ABSPRACHEN, VEREINBARUNGEN, GEWÄHRLEISTUNGEN, WEDER EXPLIZIT CH IMPLIZIT, EINSCHLIESSLICH DER GEWÄHRLEISTUNG DER EIGNUNG FÜR EINEN BESTIMMTEN ZWECK ODER DER GEBRAUCHSTAUGLICHKEIT, MIT AUSNAHME DER IN BESTEHENDEN VERTRÄGEN ZWISCHEN DEN PARTEIEN SPEZIELL VEREINBARTEN. JEDER DERARTIGE VERTRAG STELLT DIE GESAMTEN PFLICHTEN VON EATON DAR. DER INHALT DIESES DOKUMENTS IST NICHT TEIL EINES VERTRAGS ZWISCHEN DEN PARTEIEN UND VERÄNDERT AUCH KEINEN SOLCHEN. Eaton kann in keinem Fall gegenüber dem Käufer oder dem Benutzer haftbar gemacht werden, ob aufgrund eines Vertrages, unerlaubter Handlung (einschließlich Fahrlässigkeit), verschuldensunabhängig oder einer anderen Anspruchsgrundlage, für spezielle, indirekte, gleichzeitige oder Folgeschäden oder -verluste gleich welcher Art, einschließlich unter anderem Schäden oder Verluste von Geräten, Anlagen, Kapitalkosten, Leistungsverluste, zusätzliche Auslagen bei der Nutzung der vorhandenen Einrichtungen oder Ansprüchen, die Kunden infolge der Nutzung der Informationen, Empfehlungen und Beschriftungen in diesem Dokument gegenüber dem Käufer oder dem Benutzer geltend machen. Die Angaben in dieser Gebrauchsanweisung können ohne Vorankündigung geändert werden. Eaton Electrical Group 1000 Eaton Boulevard Cleveland, OH44122 United States 877-ETN-CARE (877-386-2273) Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. IL01301054EH03 April 2014 Eaton is a registered Trademark All other Trademarks are property of their respective owners. 6