MA023 (de_en) Montageanleitung. MA023 (de_en) Assembly instructions. Panel receptacle ID/B16BV-NS-A, ID/S16BV-NS with bayonet locking

Ähnliche Dokumente
MA049 (de_en) Montageanleitung. MA049 (de_en) Assembly instructions. Locking ring VR10BV for socket couplers KBT10BV-AX/M...-C...

MA (de_en) Montageanleitung. MA (de_en) Assembly instructions. CombiTac connectors for high voltage Ø 3mm

MA048 (de_en) Assembly instructions. MA048 (de_en) Montageanleitung

MA030 (de_en) Montageanleitung. MA030 (de_en) Assembly instructions. Flact contact clamp FSA20K..., FSA20A... for self assembly

Montageanleitung Assembly Instruction Artikel: Werkstattschrank mit 2 Türen

MA223 (de_en) Assembly instructions. MA223 (de_en) Montageanleitung

Aufbaudose mit Schalter Spacing box with switch. Montageanleitung mounting instructions

Installation manual / Montageanleitung WBC2 splice patch with Fibertray Spleissung/Rangierung mit Fibertray

Um die Originalschrauben an den Federbeinen zu demontieren, bedarf es eines Yamaha Spezialwerkzeugs: Torxnuss T40 mit Bohrung

Optional (siehe / see MA252) PV-SSH4 Sicherungshülse Safety lock clip

Ladeluftkühler / Intercooler Honda Civic Type R Kit-Nr.:

ZU Endlagenschalter, elektrisch für WA 131 / 131 H Limit Switch, Electrical, for WA 131 / 131 H.

Technische Mitteilung / Service Bulletin. PRIORITY 1 Safety

Umschaltadapter/ Changeover / Trennadapter Disconnection Adapter für LSA-PLUS NT for LSA-PLUS NT. Montageanweisung Mounting Instructions

Einbau- und Montageanleitung Wanddurchführungs-Set Seite 3-4 Assembly instructions and mounting guide Wall pipe set Page 5-6

Electrical testing of Bosch common rail piezo injectors

Postfach / P.O.Box 1430 D Markdorf Tel.: / Fax: / 6218 Internet: Mail:

Alurack. HONDA CRF 1000 L Africa Twin. Artikel Nr.: / Item-no.: schwarz / black

Ladeluftkühler / Intercooler Renault Megane RS Kit-Nr.:

Service Manual Service Anleitung U 58/7 KIT

Push-Pull Subminiature

Hypex d.o.o. Alpska cesta 43, 4248 Lesce Slovenija Tel: +386 (0) Fax: +386 (0)

Bajonett NCC Miniatur Bayonet NCC Miniature

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Accessoires

Montage. HONDA NC 700 X / 750 X / DCT Alurack. HONDA NC 700 S / 750 S / DCT Alurack

Alurack: Easyrack: Montage. Alurack. Easyrack YAMAHA XJR 1300

Motorschutzbügel/ Engine guard inkl. ProtectionPad

Krauser GmbH An der Steinmauer 6 D Pirmasens Tel.: Fax:

MULTIFUNKTIONSSCHALTER MULTI-FUNCTION SWITCHES

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Accessoires

Electrical testing of Bosch common rail solenoid valve (MV) injectors

FOX-150/E... FOX-350/E Solar Laderegler

InductWarm. astro s. Montageanleitung InductWarm -Tische. Assembly Instruction InductWarm Tables. Version de/eng

Montageanleitung Installation Manual

Ladeluftkühler / Intercooler Ford Focus Mk3 1.6 Ecoboost Kit-Nr.:

Guard-locking mechanism HST-TS2 Ident. No

Motorschutzplatte / Skid plate

Montageanleitung / Mounting Instruction

Montageanweisung Mounting Instructions

Montage. Motorschutzplatte. Motorschutzplatte. YAMAHA XT 1200 Z Super Tenere. YAMAHA XT 1200 Z Super Tenere. Artikel-Nr.:

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Quad-Parts Accessoires

Micro Push-Pull Subminiature

Anschlussadapterset SWR-MC

Outdoor-Tasche. Operating Instructions Bedienungsanleitung GB D

Montageanleitung Assembly Instruction Werkbank mit 6 Schubladen/ 2 Türen

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Accessoires

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Quad-Parts Accessoires

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

Optional PV-SSH4 Sicherungshülse / Safety lock clip. (siehe / see --> MA252)

SYSTEM COMPONENTS FOR 3~ RECESSED TRACK STANDARD 3~ RECESSED TRACK STANDARD. 3~ Recessed Track Standard

CABLE TESTER. Manual DN-14003

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Accessoires

Telefon: +49 (0) 5251 / Telefax: +49 (0) 5251 /

Bajonett Steckverbinder NCC IP67 Bayonet connectors NCC IP67

Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W

schwarz schwarz Montage 1 Vorbereitung: Soziussitzbank abnehmen. Zündspule herausnehmen, um die darunterliegenden Muttern der Kenn

MA223 (de_en) Assembly instructions. MA223 (de_en) Montageanleitung

Aufbau des Steckverbinders: Construction of the connector:

TriASS Schreibtische. TriASS Schreibtischsystem Montageanleitung. TriASS Desking System Assembly Instructions. Das Assmann Prinzip. Gute Arbeit.

Qualitätsmanagement-Handbuch Serviceinformation: _Serviceinformation H0201_1_Batterietrennschalter.doc Formblatt. ÜS;Linearlifte AL1

SEP-15 Rev F

1 Allgemeine Information

YOYO. Betriebsanleitung. operating instructions

Test Report. Test of resitance to inertia effects of Zirkona Backwall. Sled Test (Frontal Impact) 20 g / 30 ms

ASSEMBLY INSTRUCTIONS MONTAGEANLEITUNG. 3 Circuit ( 230V ) Tracks and Adaptors. 3 Phasen ( 230V ) Stromschienen und Adaptoren.

CELSIUS M / R / V Rack Kit. Mounting Instructions

Universalarmatur Universal armature

STILLLEGUNG CANCELLATION KIT

Gepäckbrücke. Sissybar. Montage. KAWASAKI Vulcan S. Gepäckbrücke. Sissybar mit Gepäckbrücke. Sissybar ohne Gepäckbrücke.

Montageanweisung Mounting Instructions NGC NGC NGC

Ladeluftkühler/Intercooler Ford Mustang Ecoboost EVO 1 Kit Kit-Nr.:

Rear carrier Moto Guzzi Bellagio. Item - No.: black. Assembling instructions. Luggage ideas.

WE-EF LEUCHTEN. Montage- und Wartungshinweise für Linear-Wandleuchten Serie VLR100 LED

Partyzelt

OCT 2002 Rev A1 EC: EGD

Sixpack with NTC. Features / Eigenschaften. power range up to 1,2 kv / 25 A (trench) 3 Phase IGBT FRED Inverter Bridge 6-Pack flow concept NTC

11Winkel + Flansche. Angles + flanges. Winkel + Flansche/Angles + flanges 401

SensorView 890 HSD

Tilt Wall. Montage- und Gebrauchsanleitung. Assembly instructions and manual.

Subminiatur Rundsteckverbinder Serie 711 Subminiature circular connectors series 711. Kurzinformation Brief information Ü TI

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Quad-Parts Accessoires

M9 IP40 Subminiature. Cable Connectors Screw termination M9 2 8 contacts Degree of protection IP40 1) Solder termination Diameter 11.

Montage YAMAHA MT / ABS. Art.-Nr.: schwarz

Snap-in IP67 Subminiature

Montageanweisung Mounting Instructions. ADSL/VDSL2 Splitter ADSL/VDSL2 Splitter

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

Mar-2006 Rev B

1. Verwendung des Teilesatzes. 2. Komponenten des Teilesatzes

Seitenkoffer Topcases Gepäckträger Lock it System Softbags Aluminiumkoffer Lederkoffer Schutzbügel Hauptständer Chopper-Parts Quad-Parts Accessoires

Bedienungsanleitung Operation Manual

Application Specification. 8 way VQM Hybrid Connector

PoE Kit Mounting Instructions SG/XG 210/230/310/330/430/450

HPS /B Revision: 01. Hauptständer KTM 990 SM-T / SM-R '09 Center Stand KTM 990 SM-T / SM-R '09

Cleaning & Disinfection of Eickview Videoendoscopes

M12 Automatisierungstechnik - Sonder - US-Kodierung M12 Automation Technology - Special - US-Coding

Deceleration Technology. Rotary Dampers mit hohem Drehmoment WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

Installation guide for Cloud and Square

Cable Tester NS-468. Safety instructions

M12 Automatisierungstechnik - Sonder - T-Kodierung M12 Automation Technology - Special - T-Coding

IP65 INOX-Tastaturen und Tastaturablagen für PRO-Geräte Produktinformation

Transkript:

MA023 (de_en) Montageanleitung Einbaudosen ID/B16BV-NS-A, ID/S16BV-NS mit Bajonettverriegelung Inhalt Sicherheitshinweise2 Notwendiges Werkzeug...3 1. Steckverbindermontage...3 2. Montage des Schutzdeckels...4 3. Montage des Mikroschalters...4 Funktionskrontrolle des Mikroschalters...5 4. Montage der Anschlussleitung...5 Kodierung...6 Wichtige Hinweise...6 MA023 (de_en) Assembly instructions Panel receptacle ID/B16BV-NS-A, ID/S16BV-NS with bayonet locking Content Safety Instructions 2 Tools required...3 1. Connector assembly...3 2. Protective cover assembly...4 3. Installation of microswitch...4 Functional check of microswitch...5 4. Cable connection...5 Coding...6 Important notice...6 Mikroschalter Microswitch ID/B16BV-NS-A 14.0047 ID/S16BV-NS 14.0040 MS-ID/S16BV-NS 14.0100 (für/for 14.0040) MS-B16BV-NS 14.0102 (für/for 14.0047) 1 / 8

Sicherheitshinweise Die Montage und Installation der Produkte darf ausschliesslich durch qualifiziertes und erfahrenes Fachpersonal unter Berücksichtigung aller anwendbaren gesetzlichen Sicherheitsbestimmungen und Regelungen erfolgen. Stäubli Electrical Connectors (Stäubli) lehnt jegliche Haftung infolge Nichteinhaltung dieser Warnhinweise ab. Benutzen Sie nur die von Stäubli angegebenen Einzelteile und Werkzeuge. Weichen Sie nicht von den hier beschriebenen Vorgängen zur Vorbereitung und Montage ab, da sonst bei der Selbstkonfektionierung weder die Sicherheit noch die Einhaltung der technischen Daten gewährleistet ist. Ändern Sie das Produkt nicht in irgend einer Weise ab. Nicht von Stäubli hergestellte Steckverbindungen, die mit Stäubli-Elementen steckbar sind und von einigen Herstellern manchmal auch als Stäubli-kompatibel bezeichnet werden, entsprechen nicht den Anforderungen für eine sichere, langzeitstabile elektrische Verbindung und dürfen aus Sicherheitsgründen nicht mit Stäubli-Elementen gesteckt werden. Stäubli übernimmt daher keine Haftung, falls diese von Stäubli nicht freigegebenen Steckverbindungen mit Stäubli-Elementen gesteckt werden und deshalb Schäden entstehen. Die hier beschriebenen Arbeiten dürfen nicht an stromführenden oder unter Spannung stehenden Teilen durchgeführt werden. Der Schutz vor einem elektrischen Schlag muss durch das Endprodukt (d.h. dem korrekt konfigurierten Steckverbinder) gegeben sein und vom Anwender selbst sichergestellt werden. Die Steckverbindungen dürfen nicht unter Last getrennt werden. Das Stecken und Trennen unter Spannung ist zulässig. Vor jedem Gebrauch ist durch Besichtigen (im besonderen die Isolation) zu prüfen, ob keine äusseren Mängel vorhanden sind. Wenn Zweifel bezüglich der Sicherheit bestehen, muss ein Fachmann hinzugezogen werden oder der Steckverbinder muss ausgetauscht werden. Die Steckverbinder im Gehäuse sind vor Wasser geschützt gemäss der für das jeweilige Produkt angegebenen IP-Schutzart. Nicht gesteckte Steckverbinder sind vor Feuchtigkeit und Schmutz zu schützen. Die Steckverbinder dürfen nicht im verschmutzten Zustand miteinander gesteckt werden. Weitere technische Daten entnehmen Sie bitte dem Produktkatalog. Safety instructions The products may be assembled and installed exclusively by suitably qualified and trained specialists duly observing all applicable safety regulations. Stäubli Electrical Connectors (Stäubli) does not accept any liability in the event of failure to observe these warnings. Use only the components and tools specified by Stäubli. In case of self-assembly, do not deviate from the preparation and assembly instructions as stated herein, otherwise Stäubli cannot give any guarantee as to safety or conformity with the technical data. Do not modify the product in any way. Connectors not originally manufactured by Stäubli which can be mated with Stäubli elements and in some cases are even described as Stäubli-compatible by certain manufacturers do not conform to the requirements for safe electrical connection with long-term stability, and for safety reasons must not be plugged together with Stäubli elements. Stäubli therefore does not accept any liability for any damages resulting from mating such connectors (i.e. lacking Stäubli approval) with Stäubli elements. The work described here must not be carried out on live or load-carrying parts. Protection from electric shock must be assured by the end product (i.e. by the correctly assembled plug connector) and by its user. The plug connections must not be disconnected under load. Plugging and unplugging when live is permitted. Each time the connector is used, it should previously be inspected for external defects (particularly in the insulation). If there are any doubts as to its safety, a specialist must be consulted or the connector must be replaced. The plug connectors in the housing are protected from water in accordance with the IP protection class stated for the relevant product. Unmated plug connectors must be protected from moisture and dirt. The male and female parts must not be plugged together when soiled. For further technical data please see the product catalogue. Erklärung der Symbole Warnung vor gefährlicher elektrischer Spannung Warnung vor einer Gefahrenstelle Nützlicher Hinweis oder Tipp Explanation of the symbols Warning of dangerous voltages Warning of a hazard area Useful hint or tip 2 / 8

17 15Nm 1 Notwendiges Werkzeug (ill. 1) Drehmomentschlüssel SW17, 15 Nm Tools required (ill. 1) Torque spanner 17mm A/F, 15 Nm (ill. 2) Steckschlüssel zu Drehmomentschlüssel (ill. 1) ID16BV-WZ, Bestell-Nr. 14.5019 (ill. 2) Socket wrench for torque spanner (ill. 1) ID16BV-WZ, Order No. 14.5019 2 24 30Nm 3 (ill. 3) Drehmomentschlüssel SW24, 30 Nm (ill. 3) Torque spanner 24 mm A/F, 30 Nm 4 (ill. 4) Gabelschlüssel SW24 (ill. 4) Open-end spanner 24 mm A/F 5 (ill. 5) Schraubendreher Gr. 2 (wird nur für die Montage des Mikroschalters benötigt). (ill. 5) Screwdriver size 2 (required only for microswitch assembly). 6 7 (ill. 6) Hammer und Durchschlag Ø 8 mm. (wird nur für die Montage des Mikroschalters benötigt). (ill. 6) Hammer and punch (max. Ø 8 mm) (required only for microswitch assembly) 1. Steckverbindermontage 1. Connector assembly (ill. 7) Fronttafel A gemäss Bohrplan bohren. Den Farbring (wenn vorhanden) auf Fronttafel A aufkleben. Bei Montage eines Schutzdeckels DE16N (MA036), darf der Farbring nicht montiert werden. Die Farbkennzeichnung erfolgt mit dem Schutzdeckel. (ill. 8) Ringmutter (4) und PUR-Ring (3) von Buchse (1) bzw. Stecker (2) demontieren. (ill. 7) Drill front panel A according to drilling plan. Bond coloured ring (if available) to front panel A. Stick the coloured ring (if present) on front panel A. The coloured ring must not be affixed if a protective cover DE16N (MA036) is used. In this case colour coding is effected with the protective cover. (ill. 8) Remove ring nut (4) and PUR ring (3) from socket (1) or plug (2). 8 (ill. 9) Buchse (1) bzw. Stecker (2) mit der Dichtung (5) von vorne in die Fronttafel A stecken und dabei die Nocken an der Buchse bzw. am Stecker mit den Aussparungen in der Fronttafel ausrichten. Buchse (1) bzw. Stecker (2) so ausrichten, dass das weisse Markierungsdreieck beim Steckvorgang gut sichtbar ist. (ill. 9) Insert socket (1) or plug (2) with seal (5) into front panel (A), making sure that the lugs on the plug or socket mate with the opening s slots. Align socket (1) or plug (2) so that white triangle is visible during plugging. 9 3 / 8

10 (ill. 10) PUR-Ring (3) und Ringmutter (4) montieren. Die Rillen der Ringmutter müssen gegen den PUR-Ring gerichtet sein (siehe Detailzeichnung X). Ringmutter mit Stäubli-Steckschlüssel und Drehmomentschlüssel anziehen. Anzugsdrehmoment: 15Nm. 2. Montage des Schutzdeckels siehe separate Montageanleitung MA036. (ill. 10) Mount the PUR ring (3) and the ring nut (4). Arrange the grooves of the ring nut toward the PUR-ring (see detail drawing X). Tighten the ring nut with Stäubli-socket wrench and with torque spanner. Tightening torque: 15Nm. 2. Protective cover assembly see separate assembly instruction MA036. 3. Montage des Mikroschalters 3. Installation of microswitch Hinweis: Mit montiertem Mikroschalter ist die Wasserdichtheit (IP65) nicht mehr gewährleistet. Note: With the installated microswitch the watertightness can not be guaranteed. 11 (ill. 11) Schutzhaut am Durchgangsloch (P) der Buchse (1) bzw. des Steckers (2) mit einem Durchschlag durchbrechen. Darauf achten, dass sich kein Durchbruchmaterial im Stecker bzw. in der Buchse befindet. Bevor der Mikroschalter aufgeschraubt wird, muss die Einbaudose in die Fronttafel eingebaut werden (siehe ill. 7 bis ill. 10). (ill. 12) Mikroschalter (5a) auf die Buchse (1) mit der Schraube M3 anschrauben. Mikroschalter (5a) auf der Buchse (1) gut in die Aussparung legen und mit der Schraube (M3) anschrauben. Mikroschalter (5b) mit Plättchen (U) unterlegt, auf den Stecker (2) mit der Schraube M3 anschrauben. Mikroschalter (5b) auf den Stecker (2) gut in die Aussparung legen und mit der Schraube (M3) anschrauben. Der Mikroschalter-Kontakt mit Umschaltkontakt hat 3 Steckanschlüsse 2.8x0.5 und eine Schaltleistung von 6A, 250VAC. (ill. 11) Break the protection membrane of the through-hole (P) of the socket (1) or plug (2) with a punch. Be careful that the socket resp. the plug is free from the broken material. Before fastening the microswitch, the panel receptacle has to be assembled into the front panel (see ill. 7 to ill. 10). (ill. 12) Fasten microswitch (5a) to socket (1) with the M3 screw. Firmly insert the microswitch (5a) in the recess (1) on the socket and fix in place with the screw (M3). Fasten microswitch (5b) together with mounting plate (U) to the plug (2). Fimly insert the microswitch (5b) in the recess (2) on the plug and fix in place with the screw (M3). The microswitch contact is a changeover contact. Type of connection: 3 plug connectors 2.8x0.5, switching capacity 6A, 250VAC. 12 4 / 8

13 Funktionskrontrolle des Mikroschalters Der Mikroschalter schaltet unmittelbar bevor die Verriegelung einrastet und zeigt damit an, dass die Steckverbindung hergestellt ist. Hinweis: Die korrekte Verriegelung ist erst nach dem Einrasten sichergestellt. 4. Montage der Anschlussleitung (ill. 13) Mutter (9), Unterlegscheibe (7) und Federscheibe (8) lösen. (ill. 14) Kabelschuh (D) mit angeschlossener Leitung auf das Gewinde schieben. Unterlegscheibe (7), Federscheibe (8) und Mutter (9) montieren. Mutter (9) mit Drehmomentschlüssel SW24 anziehen und mit Gabelschlüssel SW24 und Mutter (10) kontern. Anzugsdrehmoment 30Nm. Functional check of microswitch By switching immediately prior to engagement of the interlock, the microswitch indicates that the plug connection is made. Note: Correct interlocking is achieved only after engagement. 4. Cable connection (ill. 13) Remove nut (9), washer (7), and lock washer (8). (ill. 14) Slip cable lug (D) with preassembled cable onto the thread. Reinstall nut (9), washer (7) and lock washer (8). Tighten nut (9) with the torque spanner 24mm A/F and secure it with nut (10) and the open-end spanner 24mm A/F. Tightening torque 30Nm. 14 5 / 8

Kodierung (Nur...NS Typen) Es gibt max. 6 Kodiermöglichkeiten, gekennzeichnet mit C1 bis C6. Folgende Kodierzuordnung wird zur Sicherstellung der Auswechselbarkeit empfohlen: Coding (...NS series only) There are a maximum of 6 coding possibilities, designated from C1 to C6. The following coding is recommended to safeguard the interchangeability: Bezeichnung Designation Symbol Kodier-Nr. Coding-No. Farbe Colour Phase 1 L1 C1 Phase 2 L2 C2 Phase 3 L3 C3 Neutral N C4 Erde/ground PE C5 - - C6 Durch Kunden festzulegen To be defined by the customer Wichtige Hinweise zum Steckund Trennvorgang der Steckverbindung 16BV: - bei kodierten Steckverbindungen sind nur Stecker mit Buchsen steckbar, die die gleiche Kodier-Nr. aufweisen. (Eingeprägt unmittelbar beim weissen Dreieck). Hinweis: Ein kodierter Stecker kann aber mit einer unkodierten Buchse gesteckt werden. 1. Steckvorgang: Die Steckverbindung ist mit einer Bajonettverriegelung ausgerüstet. 1.1. Weisse Markierungen von Steckerseite und Buchsenseite müssen axial gegenüberstehen. 1.2. Steckverbindung bis zum Anschlag zusammenstecken 1.3. Mit axialem Druck tieferstecken und gleichzeitig die Drehung nach rechts einleiten. Während der Drehung den axialen Druck wieder lösen, sodass nach 90 die Verriegelung selbständig einrastet. Hinweis: Bei einer Drehbewegung von mehr als 90 wird der Trennvorgang wieder eingeleitet. Important notice to Plugging and Unmating procedure of 16BV connectors: - With coding connectors the plugs can only be inserted into sockets with the same code no. (inscribed code is next to the white triangle). Note: A coded plug though, can be plugged into an uncoded socket. 1. Plugging procedure: This plug connector is equipped with a bayonet locking system. 1.1. the white marks on the male and female halves must be in line. 1.2. Push the two halves together until resistance is met 1.3. Press in more deeply and twist to the right. While twisting, relax the pressure so that the latch engages automatically after turning through 90. Note: Rotation through more than 90 in relation to the marked position initiates the unmating process 6 / 8

2. Prüfvorgang: 2.1. Durch eine Drehbewegung (ohne Tieferstecken) prüfen ob die Verriegelung im Eingriff ist. 2.2. Durch Zug prüfen, ob die Verbindung in dieser Position mechanisch nicht mehr getrennt werden kann. 3. Trennvorgang: 3.1. Die Steckverbindung axial tieferstecken, und gleichzeitig um 90 nach links drehen, bis sich die weissen Markierungen axial gegenüberstehen. 3.2. Stecker und Buchse trennen. 2. Test Procedure: 2.1. By twisting the connectors (without pushing further together), test that the locking mechanism is engaged. 2.2. By attempting to simply pull the connectors apart, test that the connection in this position can no longer be mechanically separated. 3. Unmating: 3.1. Press in more deeply and then twist to the left through 90 until the white triangular marks are in line with each other. 3.2. Separate the male and female parts. 7 / 8

Notizen/Notes: Hersteller/Producer: Stäubli Electrical Connectors AG Stockbrunnenrain 8 4123 Allschwil/Switzerland Tel. +41 61 306 55 55 Fax +41 61 306 55 56 mail ec.ch@staubli.com www.staubli.com/electrical by Stäubli Electrical Connectors AG, Switzerland MA023 01.2017, Index a, Marketing Communications Änderungen vorbehalten / Subject to alterations 8 / 8