CDM Anschlussmodul Connection Module. 1. Produkteigenschaften. 1. Features

Ähnliche Dokumente
Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) 1. Features. On request. 3. Installation

Lichtschranke (Lesetakt) Photo reflex switch (Reading clock) Schalter/switch Teach-in matchcode. 1. Features

Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) 1. Features. 3. Installation

CDM Anschlussmodul für Barcodescanner CLV480, CLV490 und CLX490. Connection Module for CLV480, CLV490 and CLX490 Bar Code Scanner

Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) 1. Features

Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) Wählbare Funktionen Variable functions. 2. Features

Lichtschranke (Lesetakt) Photo reflex switch (Reading clock) Schalter/switch Teach-in matchcode. 1. Features

Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) Schalter/switch Teach-in matchcode. 2. Features

ID Sensor. Lichtschranke (Lesetakt) Photo reflex switch (reading clock) Schalter/switch Teach-in matchcode. 2. Features

Lichtschranke (Lesetakt) Photo reflex switch (Reading clock) Schalter/switch Teach-in matchcode. 2. Features

ABB i-bus EIB. EIB Power Supply Units

Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) 1. Features

Einbauanleitung Komfort CAN Bus Interface 62240

Installation Instructions

HEAG 151, 152, 153, 154 Digital Converter

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

Datenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs

LAN-Mini/R-485 Handbuch Manual

JX3-PS1. Installationsanleitung. Version Lieferumfang

Reflector Type STANDARD: Reflector Type CUSTOM:

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Aviar, Weiß-satiniert, V AC/50-60Hz, 40,00 W. Technische Daten.

Magnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät

Electrical testing of Bosch common rail piezo injectors

SY-720SC. SCART to HDMI Scaler OPERATION MANUAL

EL-21SY. 2 in, 1 out v1.3 HDMI Switcher OPERATION MANUAL

Lichtschranke. (Lesetakt) Photo reflex switch (Reading clock) 2. Features

CABLE TESTER. Manual DN-14003

USB Kabelkonfektion USB cabels assembly

Barcodescanner CLV63x, CLV64x und CLV65x mit Heizung

A VGA monitor of the highest resolution that you will be using on any computer in the installation A PS/2 Keyboard A PS/2 Mouse

CL I IP20. 9MX056 MDU-PWR Starter Set/Extension Set. Mounting instructions. New Installation/Neuinstallation. 9MX056 MDU-PWR Starter Set

MU-307 A SAFETY INSTRUCTIONS SICHERHEITSHINWEISE FEATURES MERKMALE

Alpha 2T EINBAUANLEITUNG MOUNTINGINSTRUCTIONS

M12 Verteilerinsel / M12 Splitter box

UCON/s UCON/s Kurzanleitung Inbetriebnahme

Datenblatt / Data sheet

INSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示

CAN-Bus RPM adapter. User Manual Anwender-Beschreibung

UNIGATE CL Konfiguration mit WINGATE

rs232 DIN rail adapter für Thyro-s, thyro-a und thyro-ax

GmbH, Stettiner Str. 38, D Paderborn

(825M) 2-Draht-Sender

Aufbaudose mit Schalter Spacing box with switch. Montageanleitung mounting instructions

Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W

Analog GSM-Gateway TRF

Produktinformation Access-Gateway. Product information Access gateway AGW 670-0

TW-75-IP40Trackball. Trackball module of industrial applications, ball diameter 75 mm, degree of protection IP40. Description

Installation guide for Cloud and Square

Bedienungsanleitung User Manual. PCMCIA Reader B1

Produktdatenblatt. Artikel Nr.: Deckeneinbauring, Mizar I, Weiß-matt, 12V AC/DC, 1x max. 35,00 W. Technische Daten.

USB -> Seriell Adapterkabel Benutzerhandbuch

Interconnection Technology

Schutzart IP 20 protection degree IP 20 18

PoE Kit Mounting Instructions SG/XG 210/230/310/330/430/450

AU-D2. Coaxial/Optical Audio Converter OPERATION MANUAL

Montageanleitung Konverter RS422 - USB

UL Recognized File No. E Maintenance or programming interface D-Sub plug, 9 way Service- oder Programmierschnittstelle D-Sub-Stecker 9-polig

DATENBLATT / DATASHEET

PR0111-S. 16 Kanal E/A Modul / 16 Channel IO Module. Artikel-Nr. / Article-No: 50364

Barcodescanner CLV62x / CLV620 / Mid Range

UWC 8801 / 8802 / 8803

Table of Cont 6. 2 General Information... 4 Purpose...4 Documentation...4 Scope of Supply...5 Technical Data Safety Regulations...

Technisches Datenblatt Technical Data Sheet A4B. Signalwandler für 4 analoge Eingangssignale 4-20mA auf CAN

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

LED Treiber: Anschlussschemata LED driver: connection diagrams

Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung

Aufgabenstellung Mit welchen SICLOCK Produkten kann ich einen PC Zeitsynchronisieren?

Anschluss Smart Kamera VS-05 Connection Smart Camera VS-05

SBCO-RS232-NR SBCO-RS485-NR

Table of Contents. Table of Contents Building management systems Industrial wiring installation EST 4 Programmable miniature control systems (24V)

Steuer-, Sicherheits- und Trenntransformator STE Control-, safety isolating- and isolating transformer STE Range

ems2.cp04d [ ] Automationsstation 14 Multifunktionseingänge, 6 Relaisausgänge, 4 Analoge Ausgänge DIGICONTROL Anwendung

TomTom WEBFLEET Tachograph

Technisches Datenblatt Technical Data Sheet. Drehzahlsensoren / Speed Sensors 1 Kanal Hall M14 LD Familie 1 Channel Hall M14 LD Type

Optik Konverter für Profibus Optical converter for Profibus

Sensors Monitoring Systems

CMC400. Parameterspeicher Parameter Memory

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL

Montageanleitung zum Einbau und Betrieb der seriellen QUATECH PC-High-Speed Schnittstellenkarte

Overview thermostat/ temperature controller

- Messdaten herunterladen - Diagnosis and Analysis of measuring data. - Download of measuring data

Ein- und Ausgangsspannung V / Leistung: 800 VA / Abmessungen: 203 x 147 x 445mm / Gewicht: 20kg / Normenzertifikate: EN 60950, EN

Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen

Certificate of conformity Generating unit, NS-protection

CS 80 MAGNEO Zusatzset Sensorik add. set for safety sensor DORMA IRIS ON ACTIV8 ONE ON. Jupiter. Art Motion

Cameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe

Geeignete Dübel und Schrauben verwenden! Use suitable wall plugs and screws!

Leistung output EI42/14,8 4,8VA 2 EI42/14,8 4,8VA 3 EI42/14,8 5,6VA 4 EI42/14,8 5,6VA 5 EI42/20 8VA 6 EI42/20 8VA 7

Batterie-Identifikations-Modul EL-BIM

Ethernet Connection Ecograph / Memograph / Energy and Application Manager

SIMATIC Industrie-PC IPC477D PRO Produktinformation

i500 Diagnosemodule, Blindkappe Diagnostic modules, blanking cover Montageanleitung Mounting Instructions

CAN-Bus-Systems. Microprocessor-controlled Can-Bus-node with digital and analog signal in- and outputs.

Release Notes BRICKware Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0

0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316

Signal Processing Präzisions-Sinusvervielfacher Wandlung von SinCos-Gebersignale in vervielfachte SinCos-Ausgangssignale

halbrundes oder rechteckiges Profil semicircular or rectangular profile

model protecto I

Transkript:

CDM420-0001 1D/2D Code Reader......... CDM420-0001 Aux CAN PC CAN bus Anschlussmodul Connection Module Lichtschranke (Lesetakt) Photo reflex switch (Reading clock) Schalter/switch Teach-in matchcode Sensor 1 Sensor 2 V S Host Result 1 Result 2 HOST SPS/ PLC 1. Produkteigenschaften Modular aufgebautes Anschlussmodul zum Anschluss eines SICK 1D/2D-Codelesers an Host, CAN-Scanner-Netzwerk, Feldbussysteme sowie an Peripherie und Stromversorgung. Unterstützte 1D/2D-Codeleser: Barcodescanner CLV42x... 45x, CLV6xx sowie Image Code Reader ICR84x-2, ICR85x-2. Basisgerät CDM420 zur optionalen Aufnahme eines Cloning-Moduls CMC400/CMC600 für externe Speicherung der Konfigurationsparameter des 1D/2D-Codelesers eines Display-Moduls CMD400, eingebaut in Deckelvariante, zur Anzeige von Leseergebnissen und Lesediagnosedaten des 1D/2D-Codelesers eines Feldbus-Moduls CMF400 zur Anbindung des 1D/2D- Codelesers an PROFIBUS-DP, DeviceNet oder Ethernet TCP/IP eines Power-Supply-Moduls CMP400 zur Stromversorgung des 1D/2D-Codelesers aus einem Wechselstromnetz Über CMC600: zusätzlich zwei Schalteingänge für CLV 42x... 45x und CLV6xx sowie zwei Schaltausgänge für CLV6xx 9-pol. D-Sub-Stecker intern, für Anschluss der seriellen Aux- Schnittstelle (RS-232) an PC zur Konfiguration/Diagnose des 1D/2D-Codelesers Variante CDM420-0101: zusätzlich serielle Host- und Aux- Schnittstelle über zwei 9-polige D-Sub-Buchsen auf Frontblende Klemmen für Host-Schnittstelle, CAN-Bus, Schaltein- und -ausgänge, Stromversorgung, Schirmung Anschluss des 1D/2D-Codelesers über 15-polige D-Sub-HD- Buchse, Peripherie an Klemmen über Kabelverschraubungen, Feldbus über systemabhängige Steckverbindungen (Frontblende) Von außen sichtbar: LEDs zur Anzeige von aktiven Schaltein- und ausgängen sowie Schalterstellungen der Modulkonfiguration Schutzart IP 65 (Variante CDM420-0101: IP 20) Wartungsfrei UL-zertifiziert bei Verwendung eines Class 2-Netzgeräts (geprüft nach UL 1310) zur Stromversorgung Weitere Produktinformationen, Programm CLV-Connect : Siehe www.sick.com EG-Konformitätserklärung: Auf Anforderung 8010004/TF10/2009-08 Betriebsanleitung 1. Features Operating Instructions Compact connection module for connecting one SICK 1D/2D code reader to the host, CAN scanner network, fieldbus systems as well as to the peripheral equipment and power supply. Supported 1D/2D code reader: bar code scanner CLV42x to 45x, CLV6xx or image code reader ICR84x-2, ICR85x-2. Basic device CDM420 for integrating optionally the following CMC400/CMC600 cloning module for saving the 1D/2D code reader s configuration parameters externally CMD400 display module (installed in a cover variant) for displaying the reading results and reading diagnosis data of the 1D/2D code reader CMF400 fieldbus module for connecting the 1D/2D code reader to PROFIBUS-DP, DeviceNet or Ethernet TCP/IP CMP400 power supply module for supplying power to the 1D/ 2D code reader from an AC power line Via CMC600: additionally 2 switching inputs for CLV 42x to 45x and CLV6xx as well as 2 switching outputs for CLV6xx. 9-pin internal D-Sub connector, for connecting the serial Aux interface (RS 232) to a PC for configuring/diagnosing the 1D/2D code reader. CDM420-0101 variant: The serial host and Aux interface can also be connected via two 9-pin D Sub sockets on face plate (front). Terminals for host interface, CAN bus, switching inputs/outputs, power supply, and shield. Connection of the 1D/2D code reader via 15-pin D-Sub HD socket, peripheral equipment to terminals via cable glands and fieldbus via system depending plug-in connections on face plate. Externally visible LEDs for displaying active switching inputs and outputs, as well as switch settings for module configuration. Enclosure rating IP 65 (CDM420-0101 variant: IP 20). Maintenance-free UL certificated when a class 2 power supply according to UL 1310 is used. Further Product Information, CLV-Connect PC Program: See www.sick.com EC Conformity Declaration: On request SICK AG Division Auto Ident Germany All rights reserved 1 # 8

HINWEIS Mögliche Funkstörungen beim Einsatz in Wohngebieten! Das Anschlussmodul CDM420 ausschließlich in Industrieumgebungen einsetzen. 2. Voraussetzungen zur Installation und Inbetriebnahme Anschlusspläne in CLV-Connect (auf CD-ROM Manuals & Software Bar Code Scanners, die dem 1D/2D-Codeleser beiliegt, oder via Internet www.sick.com) Versorgungsspannung DC 10... 30 V (erzeugt nach IEC 742), abhängig vom 1D/2D-Codeleser und ggf. weiteren Modulen im CDM420. Siehe auch 5.3 Versorgungsspannung, Seite 3 und 6. Technische Daten, Seite 5. Bei Verwendung des Power-Supply-Moduls CMP400 eine Eingangsspannung von AC 100... 250 V, 50... 60 Hz Für Barcodescanner CLV6xx ein Anschlussmodul CDM420 ab Herstellungsdatum (JJ-WW): 08-07 Ältere CDM420 können nicht zusammen mit einem CLV6xx in Kombination mit einem CMC600 betrieben werden. 3. Montage Freier Zugang zum internen Stecker AUX erforderlich für Zugriff auf den 1D/2D-Codeleser (Konfiguration/Diagnose) Max. Leitungslänge zwischen CDM420 und 1D/2D-Codeleser beim Einsatz von Verlängerungsleitungen: 10 m (serielle RS-232- Schnittstelle!) Abgenommener Deckel mit Anschlussbild um 180 gedreht in Parkposition arretierbar Bohrungs- und Gehäusemaße siehe Maßbild (Seite 6), max. Schraubendurchmesser 4 mm. Optionale Module: Einbau und Inbetriebnahme siehe Betriebsanleitung (BA)/Montageanleitung (MA): BA Parameterspeicher CMC400 (Nr. 8010002) BA Parameterspeicher CMC600 (Nr. 8012120) BA Display-Modul CMD400 (Nr. 8010372) BA Feldbus-Modul CMF400-1x01 (PROFIBUS-DP) (Nr. 8010461) BA Feldbus-Modul CMF400-2101 (DeviceNet) (Nr. 8010463) BA Feldbus-Modul CMF400-3101 (Ethernet) (Nr. 8010734) MA Power-Supply-Modul CMP400 (Nr. 8010365) Optionale Module vor Montage des CDM420 einbauen. Steckplätze im CDM420: NOTICE RF interferences in case of use in residential areas! The CDM420 Connection Module is excusively intended for use in industrial areas. 2. Installation and Commissioning Requirements Connection diagrams in CLV-Connect (on the Manuals & Software Bar Code Scanners CD-ROM provided with the 1D/2D code reader or from the Internet: www.sick.com) 10... 30 V DC power supply (generated in accordance with IEC 742), depending on 1D/2D code reader and further modules in the CDM420. See also 5.3 Supply voltage, Page 3 and 6. Technical Data, Page 5. An input voltage of 100 to 250 V AC, 50 to 60 Hz is required when using the CMP400 Power Supply Module For the CLV6xx Bar Code Scanner a connection module CDM420 up from the manufacturing date (jj-ww): 08-07 is required. Elder CDM420 can not be used with a CLV6xx in combination with a CMC600. 3. Installation Free access to internal AUX connector is required to connect to the 1D/2D code reader (configuration/diagnosis) Max. cable length between CDM420 and 1D/2D code reader if extension cables are used: 10 m (32.8 ft) because of serial RS 232 interface Cover with connection diagram can be removed, rotated by 180, and locked in park position See dimensional drawing (Page 6) for hole and housing dimensions, max. screw diameter 4 mm (0.15 in). Optional modules: For installing and commissioning see Operating Instructions (OI)/ Fitting Instructions (FI): CMC400 Cloning Module OI (no. 8010002) CMC600 Cloning Module OI (no. 8012120) CMD400 Display Module OI (no. 8010372) CMF400-1x01 Fieldbus Mod. (PROFIBUS-DP) OI (no. 8010462) CMF400-2101 Fieldbus Module (DeviceNet) OI (no. 8010464) CMF400-3101 Fieldbus Module (Ethernet) OI (no. 8010735) CMP400 Power Supply Module FI (no. 8010365) Install the optional modules before mounting the CDM420. Plug-in slots in the CDM420: Feldbus-Modul CMF400 CMF400 Fieldbus Module Cloning-Modul CMC400/CMC600 CMC400/CMC600 Cloning Module Power-Supply-Modul CMP400 CMP400 Power Supply Module 2 # 8 SICK AG Division Auto Ident Germany All rights reserved 8010004/TF10/2009-08

4. Konfigurationselemente und Anzeigen Funktion der Konfigurationsschalter: Schalter Funktion Default S 1 (Power) Anliegende Versorgungsspannung: ON ON: Versorgungsspannung ein OFF: Versorgungsspannung aus S 2 (RS-485) RS-422/485-Umschaltung: OFF ON: RS-485 OFF: RS-422 S 3 (Trm422) RS-422-Terminierung (Empfänger): OFF ON: Widerstand 120 Ohm zugeschaltet OFF: keine Terminierung S 4 (TrmCAN) Terminierung des CAN-Busses: OFF ON: Widerstand 120 Ohm zugeschaltet OFF: keine Terminierung S 6 (SGND-GND) Bezugspotenzial für Sensor-GND: ON ON: verbunden mit GND des 1D/2D- Codelesers OFF: potenzialfrei S 8 (CMC) Integration des CMC400/CMC600: NO (oben) YES : CMC in Leitung der Aux-Schnittstelle des 1D/2D-Codelesers geschaltet NO : Kein CMC gesteckt Funktion der LEDs: LED Farbe Funktion Power grün leuchtet, wenn die Versorgungsspannung am CDM420 anliegt und Schalter S 1 auf ON Sensor 1, 2 gelb leuchtet, wenn der entsprechende Eingang des 1D/2D-Codelesers schaltet Result 1, 2 gelb leuchtet, wenn der entsprechende Ausgang des 1D/2D-Codelesers schaltet Wichtig: Die zusätzlichen Eingänge Aux In 1 und 2 sowie die Ausgänge Aux Out 1 und 2 haben keine Statusanzeige durch LEDs. 5. Elektrische Installation 5.1 Datenschnittstellen Empfohlene max. Leitungslänge des 1D/2D-Codelesers zum Host: Schnittstellentyp Datenübertragungsrate Entfernung z. Host RS-232 bis 19,2 kbd max. 10 m 38,4... 57,6 kbd max. 3 m RS-422/485 max. 38,4 kbd max. 1.200 m max. 57,6 kbd max. 500 m 5.2 Zusätzliche Schaltein- und Ausgänge Die Zusatzfunktion des CMC600 unterstützt folgende Geräte: 1D/2D Codeleser zusätzliche Eingänge zusätzliche Ausgänge CLV42x... 45x 2 CLV6xx 2 2 ICR84x-2/ICR85x-2 4. Configuration Elements and Displays Configuration Switches: Switch Function Default S 1 (Power) Connected power supply: ON ON: Power supply on OFF: Power supply off S 2 (RS 485) RS 422/485 selector: OFF ON: RS 485 OFF: RS 422 S 3 (Trm422) RS 422 termination (receiver): OFF ON: 120 Ohm resistor connected OFF: No termination S 4 (TrmCAN) CAN bus termination: OFF ON: 120 Ohm resistor connected OFF: No termination S 6 (SGND-GND) Reference potential for sensor GND: ON ON: Connected to GND of 1D/2D code reader OFF: Floating S 8 (CMC) CMC400/CMC600 integration: NO (on top) YES : CMC connected to Aux interface of 1D/2D code reader NO : CMC not connected LEDs: LED Color Function Power green Lights up when the power supply is connected to the CDM420 and switch S 1 is set to ON Sensor 1, 2 yellow Lights up when the corresponding input of the 1D/2D code reader switches Result 1, 2 yellow Lights up when the corresponding output of the 1D/2D code reader switches Important: The additional inputs Aux In 1 and 2 as well as the outputs Aux Out 1 and 2 have no status indication by LEDs. 5. Electrical Installation 5.1 Data interfaces Recommended max. cable length from 1D/2D code reader to host: Interface type Data transfer rate Distance to host RS 232 Up to 19.2 kbd Max. 10 m (32.8 ft) 38.4 to 57.6 kbd Max. 3 m (9.84 ft) RS 422/485 Max. 38.4 kbd Max. 1,200 m (3,936 ft) Max. 57.6 kbd Max. 500 m (1,640 ft) 5.2 Additional switching inputs and outputs The CMC600 supports the following 1D/2D code readers: 1D/2D code reader Additional inputs Additional outputs CLV42x to 45x 2 CLV6xx 2 2 ICR84x-2/ICR85x-2 5.3 Versorgungsspannung Der 1D/2D-Codeleser benötigt typenabhängig zur Versorgung folgende Funktionskleinspannung gemäß IEC 60364-4-41: 1D/2D Codeleser CLV42x... 45x / ICR85x-2 CLV62x ICR84x-2 Versorgungsspannung DC 10... 30 V DC 10... 30 V DC 15... 30 V 5.3 Supply voltage Dependent on type the 1D/2D code reader requires the following functional extra-low voltage according to IEC 60364-4-41: 1D/2D code reader CLV42x to 45x / ICR85x-2 CLV62x ICR84x-2 Supply voltage 10 to 30 V DC 10 to 30 V DC 15 to 30 V DC 8010004/TF10/2009-08 SICK AG Division Auto Ident Germany All rights reserved 3 # 8

HINWEIS Elektrische Trennung! Der Ausgangskreis des kundenseitigen Netzgerätes zur Erzeugung der Versorgungspannung muss gegenüber dem Eingangskreis eine sichere elektrische Trennung durch Doppelisolation und Sicherheitstrafo nach IEC 742 besitzen. Power-Supply-Modul CMP400 (AC/DC): GEFAHR Verletzungsgefahr durch elektrischen Strom! Das Modul CMP400 wird an Wechselspannung AC 100... 250 V, 50... 60 Hz angeschlossen. Anschluss nur durch ausreichend qualifiziertes Fachpersonal durchführen lassen. Sicherheithinweise in der Montageanleitung des CMP400 (Nr. 8010365) beachten. Schutzleiter an Klemme PE anschließen. Wichtig: Durch Verwendung des CMP400 verliert das Anschlussmodul und der angeschlossene Barcodescanner die UL-Zertifizierung. Verdrahtung des CDM420: Elektrische Verbindungen nur im spannungsfreien Zustand herstellen oder lösen. Für alle Anschlüsse an den Klemmenleisten Kupferleitungen mit einem Aderquerschnitt von mindestens 0,14 mm 2 verwenden Um den Kurzschluss-/Überlastungschutz der abgehenden Versorgungsleitungen zum 1D/2D-Codeleser sicherzustellen, müssen die verwendeten Aderquerschnitte unter Berücksichtigung der im CDM420 eingebauten Sicherung ausgelegt werden. Folgende Normen sind zu beachten: DIN VDE 0100 (Teil 430), DIN VDE 0298 (Teil 4) bzw. DIN VDE 0891 (Teil 1) Kundenseitige Schirmung am CDM420 auflegen (Kl. Shield ) Klemmenbelegung siehe Anschlussbild, Seite 8 und im Deckel innen. Anschlusspläne für Host-/CAN-Schnittstelle/Schalteinund -ausgänge siehe CLV-Connect und Stromlaufplan (Seite 7) Variante CDM420-0101: Pinbelegung für zusätzliche 9-pol. D-Sub-Buchsen (ser. Host- und Aux-Schnittstelle) siehe Seite 8 Host-Schnittstelle EMV-gerecht über abgeschirmte Leitungen an den Host anschließen. Um Störeinflüsse zu vermeiden, Leitungen möglichst nicht parallel zu Stromversorgungs- und Motorleitungen verlegen Bezugspotenzial für die Schalteingänge mit Schalter S 6 wählen Integration in CAN-Scanner-Netzwerk: siehe Betriebsanleitung Anwendung der CAN-Schnittstelle (Nr. 8008179, dt. Ausgabe). Vorgehensweise: 1. Leitung des 1D/2D-Codelesers an die 15-pol. D-Sub-HD-Buchse des CDM420 anschließen. 2. Alle anderen Leitungen über Kabel-Verschraubungen an Klemmen auflegen. Um die Schutzart IP 65 zu erhalten, nicht verwendete Durchführungen mit Blindstopfen versehen. 3. CAN-Bus: Falls CDM420 am Busende, Terminierungswiderstand mit Schalter S 4 zuschalten 4. Mit PC-Programm CLV-Setup Treiber für verdrahtete Host-/CAN- Schnittstelle im 1D/2D-Codeleser aktivieren: Hierzu PC mit 3-adriger RS-232-Datenleitung (Nullmodemleitung) an 9-pol. Stecker AUX im CDM420-0001 anschließen Variante CDM420-0101: PC alternativ mit 3-adriger RS-232- Datenleitung (1:1) an 9-pol. Buchse AUX auf Frontplatte anschließen.stromversorgung für CDM420 einschalten. NOTICE Electrical isolation! The output circuit of the power supply pack provided by the customer must be safely electrically isolated from the input circuit by means of double insulation and a safety isolating transformer according to IEC 742. CMP400 Power Supply Module (AC/DC): DANGER Shock hazard! The CMP400 power supply module is connected to a mains voltage of 100 to 250 V AC/50 to 60 Hz. The module should only be connected by sufficiently qualified personnel. Observe the safety information in the CMP400 Fitting Instructions (no. 8010365). Connect the protective conductor to the PE terminal. Important: Using the CMP400, the UL certification for the connection module and the connected bar code scanner is not longer valid. CDM420 wiring: Connect or release current linkages only under de-energised conditions. Use copper cables with a minimum core cross-section of 0.14 mm 2 (26 AWG ) for all connections at the terminal strips. To ensure that the outgoing supply cables to the 1D/2D code reader are protected against short-circuits/overload, the core cross-sections must be dimensioned in accordance with the fuse installed in the CDM420. The valid standards must be observed. Connect the shield of your system to the CDM420 ( Shield terminal) For terminal assignment, see connection diagram on Page 8 or inside the cover. For host/can interface/switching input and output diagrams, see CLV-Connect and circuit diagram (Page 7). CDM420-0101 variant: for the pin assignment of the additional 9-pin D Sub sockets (serial Host and Aux interface), see Page 8. Use shielded cables to establish an EMC-compatible connection between host interface and host. To prevent interference, do not install cables parallel to power supply or motor cables (e.g. cable ducts). Choose reference potential for switching inputs with switch S 6. Integration in CAN scanner network: see Operating Instructions Using the CAN Interface (No. 8008180, English). Electrical Installation Procedure: 1. Connect the 1D/2D code reader cable to the 15-pin D-Sub HD socket on the CDM420. 2. Connect all other cables to the terminals. To remain enclosure rating IP 65, use blanking plugs to close any unused bushings. 3. CAN bus: if CDM420 is integrated at bus end, enable termination resistor with switch S 4. 4. Use the CLV-Setup program to activate the driver for the connected host/can interface in the 1D/2D code reader: To do so, connect the PC to the 9-pin AUX connector inside the CDM420-0001 using a 3-core RS 232 data cable (null modem cable) - CDM420-0101 variant: connect the PC alternatively to the 9-pin AUX socket on the face plate using a 3-core RS 232 data cable (1:1). Switch on the power supply für CDM420. 4 # 8 SICK AG Division Auto Ident Germany All rights reserved 8010004/TF10/2009-08

6. Technische Daten Typ CDM420-0001 (Nr. 1025362) Optische Anzeigen 5 x LED Elektrische Anschlüsse D-Sub: 15-pol. HD-Buchse/9-pol. Stecker Schraubklemmen, für Adern 0,14... 2,5 mm 2 Federkraftklemmen, für Adern 0,14...1 mm 2 Kabel-Verschraubungen 6 x (für Leitungen 4,5... 10 mm) Versorgungsspannung 1) DC 10... 30 V, SELV bzw. PELV nach IEC 60364-4-41 (2005) DC 18... 30 V bei Verwendung von Display CMD400 und/oder Feldbusmodulen Leistungsaufnahme 2) P Scanner + 0,5 W Sicherung Glasrohrsicherung 0,8 A träge Gehäuse Polycarbonat Farbe blau, Deckel transparent Prüfzeichen CE, UL Elektrische Sicherheit nach EN 61010-1 (2001-03) Schutzklasse III 3), nach EN 61140 (2002-03) Schutzart IP 65 4), nach EN 60529 (1991-10); A1 (2002-02) EMV-Prüfung nach EN 61000-6-2 (2001-10); EN 61000-6-4 (2001-10); EN 55011 (1998-05), A1 (1999-08), A2 (2002-10) Schwing-/Schockprüfung nach IEC 60068-2-27 (1993)/ nach IEC 60068-2-6 (1995) Gewicht (Basisgerät) ca. 800 g Temperatur (Betrieb/Lager) 35 5)... +40 C/ 35... +70 C Rel. Luftfeuchtigkeit max. 90 %, nicht kondensierend 1) UL-zertifiziert bei Verwendung eines Class 2-Netzgeräts (geprüft nach UL 1310) 2) abhängig vom Codeleser-Typ, ohne Display, Parameterspeicher und Feldbusmodule 3) Klasse I mit Power-Supply-Modul CMP400 und angeschlossenem PE-Leiter 4) bei Verwendung der SICK Standardanschlussleitung und geschlossener Frontblende des CDM420 (Blindplatte ohne Anschlüsse oder Platte mit IP-65-Anschluss) 5) in Ruhe (keine Montage oder elektrische Installation), sonst bis 20 C (gültig bei entsprechender Gerätekennzeichnung auf dem Typenschild) 6. Technical Data Type CDM420-0001 (no. 1025362) Visual indicators 5 x LEDs Electrical connections D-Sub: 15-pin HD socket/9-pin plug Screw terminals, for cores 0.14 to 2.5 mm 2 (approx. 26 to 13 AWG) Spring terminals, for cores 0.14 to 1 mm 2 (approx. 26 to 17 AWG) Cable glands 6 x, for cables diameter 4.5 to 10 mm (diam. 0.18 to 0.39 in) Power supply 1) 10 to 30 V DC SELV respectively PELV to IEC 60364-4-41 (2005) 18 to 30 V DC when using the CMD400 display and/or fieldbus modules Power consumption 2) P Scanner + 0.5 W Fuse Glass tube fuse 0.8 A, type T Housing Polycarbonate Colour Blue, transparent cover Conformity CE, UL Electrical safety According to EN 61010-1 (2001-03) Protection class III 3), accord. to EN 61140 (2002-03) Enclosure rating IP 65 4), accord. to EN 60529 (1991-10); A1 (2002-02) EMC tested According to EN 61000-6-2 (2001-10); EN 61000-6-4 (2001-10); EN 55011 (1998-05), A1 (1999-08), A2 (2002-10) Vibration/shock tested To IEC 60068-2-27 (1993)/IEC 60068-2-6 (1995) Weight (basic device) Approx. 800 g (approx. 28.2 oz) Temperature 35 5) to +40 C/ 35 to +70 C (operation/storage) ( 31 5) to +104 F/ 31 to +158 F) Rel. air humidity Max. 90 %, non-condensing 1) UL certificated when a Class 2 power supply according to UL 1310 is used 2) Scanner type specific, without display, parameter memory, or fieldbus modules 3) Class I with CMP400 power supply module and connected PE conductor 4) With SICK standard cable and closed face plate (dummy plate without connections or plate with IP 65 connectors) on the CDM420 5) Without any mounting or electrical installation work, otherwise 20 C ( 4 F) (valid only with corresponding product marking on the nameplate) 7. Zubehör Bestell-Nr. Beschreibung 1023850 CMC400-101 Cloning-Modul *) für 1D/2D-Codeleser (nicht für CLV6xx) 1042259 CMC600-101 Cloning-Modul *) 2029466 CMD400 Display-Modul *), 4 x 20 Zeichen, 5 Tasten 1026241 CMF400-1001 Feldbus-Modul *) für PROFIBUS-DP, IP 20 1026643 CMF400-1101 Feldbus-Modul *) für PROFIBUS-DP, IP 65 1026242 CMF400-2101 Feldbus-Modul *) für DeviceNet, IP 65 1026357 CMF400-3101 Feldbus-Modul *) f. Ethernet TCP/IP, IP 65 2029468 CMP400 Power-Supply-Modul *), Eingang AC 100... 250 V, 50... 60 Hz, Ausgang DC 24 V, Abgabe max. 10,8 W 6010075 Verlängerungsleitung für CLV42x... 45x, CLV6xx, ICR84x-2 ICR85x-2, 2 m, geschirmt, mit 15-pol. D-Sub-HD-Stecker/ Buchse 2014054 RS-232-Datenleitung (Nullmodemleitung), 3 m, geschirmt, mit 2 x 9-pol. D-Sub-Buchse, zum Anschluss an den 9-pol. D-Sub-Stecker AUX im Inneren des CDM420 *) Betriebstemperatur 0... +40 C 7. Accessories Order No. Description 1023850 CMC400-101 cloning module *) for 1D/2D code reader (not for CLV6xx) 1042259 CMC600-101 cloning module *) 2029466 CMD400 display module *), 4 x 20 digits, 5 keys 1026241 CMF400-1001 fieldbus module *) for PROFIBUS-DP, IP 20 1026643 CMF400-1101 fieldbus module *) for PROFIBUS-DP, IP 65 1026242 CMF400-2101 fieldbus module *) for DeviceNet, IP 65 1026357 CMF400-3101 fieldbus module *) for Ethernet TCP/IP, IP 65 2029468 CMP400 power supply module *), input 100 to 250 V AC, 50 to 60 Hz, output 24 V DC, max. 10.8 W 6010075 Extension cable for CLV42x to 45x, ICR 84x, CLV6xx, ICR84x-2, ICR85x-2, 2 m (6.56 ft), shielded, with 15-pin D-Sub HD plug/socket 2014054 RS 232 data cable (null modem cable), 3 m (9.84 ft), shielded, with 2 x 9-pin D-Sub socket for connecting to the 9-pin D Sub plug AUX inside of the CDM420 *) Operation temperature 0 to +40 C (+32 to +104 F) 8010004/TF10/2009-08 SICK AG Division Auto Ident Germany All rights reserved 5 # 8

Bestell-Nr. Beschreibung 6005695 Datenleitung, Meterware, twisted pair, geschirmt, für RS-232 und RS-422/485-Schnittstellen 6027048 Datenleitung CAN-BUS, Meterware, twisted pair, geschirmt Order No. Description 6005695 Data cable, cut to size, twisted pair, shielded, for RS 232 and RS 422/485 interfaces 6027048 CAN BUS data cable, cut to size, twisted pair, shielded 8. Fehlersuche für Basisgerät CDM420 8. Troubleshooting for CDM420 (Basic Device) Störung Versorgungsspg. angeschlossen, aber LED Power leuchtet nicht Signale des angeschlossenen Lesetaktsensors bleiben wirkungslos Nach Anschluss des PCs an den Stecker AUX kein Zugriff auf den 1D/2D-Codeleser mit CLV- Setup Abhilfe Schalter S 1 (Power) in Position ON bringen Lesetaktsensor gemäß CLV- Connect anschließen Schalter S 6 in richtige Position bringen (siehe Stromlaufplan) Mit Hilfe von CLV-Setup die Quelle des Lesetaktes im 1D/2D- Codeleser auf Sensor 1 einstellen. Download zum 1D/2D-Codeleser! Wenn kein CMC400/CMC600 gesteckt, Schalter S 8 in Position NO bringen Mit Hilfe der Funktion AutoBaudDetect in CLV-Setup die Kommunikationsparameter des PC automatisch wählen Malfunction Power LED does not light up when power supply is connected Signals from connected reading pulse sensor have no effect Cannot access 1D/2D Code reader with CLV-Setup after connecting the PC to the AUX connector Remedy Set switch S 1 (Power) to ON Connect reading pulse sensor in accordance with CLV-Connect Set switch S 6 to correct position (see circuit diagram) Using CLV-Setup, set the reading pulse source for the 1D/ 2D code reader to Sensor 1. Perform a download to the 1D/ 2D code reader. If no CMC400/CMC600 is connected, set switch S 8 to NO Using the AutoBaudDetect function in CLV-Setup to configure the PC communication parameters automatically Wichtig: Fehlersuche in Zusammenhang mit optionalen Modulen siehe jeweils deren Betriebs-/Montageanleitung. Important: For troubleshooting of the optional modules see the respective operating or fitting instructions. Maßbild/dimensioned drawing Nur bei Typ CDM420-0101 Type CDM420-0101 only Alle Dimensionen in mm (inch) All dimensions in mm (inch) Anschlussraum für Stecker Space required for connecting plug Anschlussraum für Stecker bei optionaler Blende mit Steckverbindungen Space required for connecting plugs when using optional face plate with plug-in connections 6 # 8 SICK AG Division Auto Ident Germany All rights reserved 8010004/TF10/2009-08

Stromlaufplan/circuit diagram 4-pin to CMP 4-pin to I/O board to CMF400 bus module +24V_Heating_Out S6: Switch INGND GND to CMC module AUX plug S7: Switch RS232 CLV41x: Terminal < > AUX S2: Switch RS422 < > RS485 S3: Switch for RS485 termination S4: Switch for CAN termination S5: Switch for CAN_2 termination 15-pin D-Sub HD socket to scanner V1: CDM420 for CLV42x / CLV43x / 44x /45x / ICR84x / ICR85x V2: CDM410 for CLV41x V3: CDM490 for CLV49x / LMS400 V4: CDM4xx for operation with CMX module for CAN multiplexer +24V_Heating_Out For MPX module (no scanner connected) 8010004/TF10/2009-08 SICK AG Division Auto Ident Germany All rights reserved 7 # 8

Aufbau, Klemmenbelegung/design, terminal assignment 8010004/TF10/2009-08 5M/TR <PM 6.5> KE Printed in Germany Subject to change without prior notice The specified product features and technical data do not represent any guarantee AftE6305sw Schema: Aufbau eines SICK CAN-Scanner-Netzwerkes Diagram: Building a SICK CAN scanner network 1D/2D Code Reader 1D/2D Code Reader 1D/2D Code Reader CDM420-0101: Pinbelegung 9-pol. D-Sub-Buchsen auf Frontblende Pin assignment of 9-pin D Sub sockets on face plate (front) AUX 6 9 1 5 HOST 6 9 1 5 CDM420 CDM420 CDM420 Host Result 1 Sensor 1 CAN bus Pin Signal 1 not connected 2 TxD (RS 232), AUX 3 RxD (RS 232), AUX 4 not connected 5 GND 6 not connected 7 not connected 8 not connected 9 not connected Klemmenleisten Codeleser Terminal strips for reader Pin Signal Colour (internal) 1 not connected 2 TxD (RS 232), white TD (RS 422) 3 RxD (RS 232), green RD (RS 422) 4 not connected 5 GND brown 6 TD+ (RS 422) yellow 7 not connected 8 RD+ (RS 422) grey 9 not connected LEDs Konfigurationsschalter Configuration switches Konfigurationsschalter Configuration switches Anschluss Codeleser Code reader connection Klemmenleisten für Versorgungsspannung Terminal strips for power supply voltage Anschluss PC PC connection SICK AG Waldkirch Germany www.sick.com 8 # 8 SICK AG Division Auto Ident Germany All rights reserved 8010004/TF10/2009-08