Newest Generation of the BS2 Corrosion/Warning and Measurement System

Ähnliche Dokumente
Quadt Kunststoffapparatebau GmbH

Shock pulse measurement principle

Pilot Project Biogas-powered Micro-gas-turbine

TomTom WEBFLEET Tachograph

UWC 8801 / 8802 / 8803

Cleanroom Fog Generators Volcano VP 12 + VP 18

Anleitung zur Verwendung des Update-Tools für

Hazards and measures against hazards by implementation of safe pneumatic circuits

- Characteristic sensitive Small temperature differences. - Low Sensitivity 42,8 µv/k for Cu-Constantan

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016

Serviceinformation Nr. 05/10

Cameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe

NIKOTINSUCHT - DIE GROßE LüGE: WARUM RAUCHEN NICHT SüCHTIG MACHT UND NICHTRAUCHEN SO EINFACH SEIN KANN! (GERMAN EDITION)

CABLE TESTER. Manual DN-14003

MATLAB driver for Spectrum boards

Interconnection Technology

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016

Network premium POP UP Display

CSC 500 Sensor System for Ring Electrode and ISC CSC 500 Sensor System für Ring Elektrode und ISC

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

NETWORK PREMIUM POP UP DISPLAY

Data-S EASY VERSTREUTE ÜBERWACHUNG DER NOTBELEUCHTUNG

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient

Lufft UMB Sensor Overview

ABB i-bus EIB. EIB Power Supply Units

Einsatz einer Dokumentenverwaltungslösung zur Optimierung der unternehmensübergreifenden Kommunikation

PONS DIE DREI??? FRAGEZEICHEN, ARCTIC ADVENTURE: ENGLISCH LERNEN MIT JUSTUS, PETER UND BOB

Customer-specific software for autonomous driving and driver assistance (ADAS)

C-TEC Systemtechnik und Serviceleistung für die Werkstoffprüfung GmbH

Westenberg Wind Tunnels

1. Hardware Configuration Hardware-Konfiguration Software-Konfiguration Software Configuration...4

Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit Pool water quality the German philosophy

ZWISCHEN TRADITION UND REBELLION - FRAUENBILDER IM AKTUELLEN BOLLYWOODFILM (GERMAN EDITION) BY CHRISTINE STöCKEL

ZK2000SF ACCESS CONTROL ZUTRITTSKONTROLLE

Instruktionen Mozilla Thunderbird Seite 1

Model-based Development of Hybrid-specific ECU Software for a Hybrid Vehicle with Compressed- Natural-Gas Engine

Meteorological measurements at the Offshore Platform FINO 2 - new insights -

Presentation of a diagnostic tool for hybrid and module testing

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 7550 WRD-H 9565 WRD-H

1. General information Login Home Current applications... 3

CNC ZUR STEUERUNG VON WERKZEUGMASCHINEN (GERMAN EDITION) BY TIM ROHR

Externer Temperaturfühler External temperature sensor

Produktdatenblatt. Artikel Nr.: Wandaufbauleuchte, Alpha II, Weiß, V AC/50-60Hz, 100,00 W. Technische Daten.

Ingenics Project Portal

Level 1 German, 2016

Operation Guide AFB 60. Zeiss - Str. 1 D Dauchingen

New ways of induction heating in the injection moulding process

HYDRAULIK UND PNEUMATIK ROTORDICHTUNG HYDRAULIC AND PNEUMATIC GLIDE SEAL C1R

Kraftwerk Berlin. Today, this formerly silenced Berlin power station is a vibrant place for exhibitions and events. A space resonating with energy.

Tenting plugging Filling

Der Adapter Z250I / Z270I lässt sich auf folgenden Betriebssystemen installieren:

STRATEGISCHES BETEILIGUNGSCONTROLLING BEI KOMMUNALEN UNTERNEHMEN DER FFENTLICHE ZWECK ALS RICHTSCHNUR FR EIN ZIELGERICHTETE

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät

(825M) 2-Draht-Sender

Titelmasterformat Object Generator durch Klicken bearbeiten

Parameter-Updatesoftware PF-12 Plus

MHG - Modular Humidity Generator


Exercise (Part XI) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1

USBASIC SAFETY IN NUMBERS

Motion Controller 2 - MC2

Communications & Networking Accessories

Technology for you. Media Solutions

Serviceinformation Nr. 02/11

Wiegen / Balance Inhaltsübersicht Contents Seite / Page

Rough copy for the art project >hardware/software< of the imbenge-dreamhouse artist Nele Ströbel.

Robotino View Kommunikation mit OPC. Communication with OPC DE/EN 04/08

Aufbau eines IT-Servicekataloges am Fallbeispiel einer Schweizer Bank

Kalibrierschein Calibration Certificate

Titelbild1 ANSYS. Customer Portal LogIn

Introduction FEM, 1D-Example

Level 1 German, 2012

How to access licensed products from providers who are already operating productively in. General Information Shibboleth login...

Sensoren / Sensors XA1000 / XP200 / XP400 XP100 / XP101.

FEM Isoparametric Concept

ETHISCHES ARGUMENTIEREN IN DER SCHULE: GESELLSCHAFTLICHE, PSYCHOLOGISCHE UND PHILOSOPHISCHE GRUNDLAGEN UND DIDAKTISCHE ANSTZE (GERMAN

How-To-Do. OPC-Server with MPI and ISO over TCP/IP Communication. Content. How-To-Do OPC-Server with MPI- und ISO over TCP/IP Communication

SARA 1. Project Meeting

Level 2 German, 2015

MULTI PHYSICS SIMULATION IN MANUFACTURING

POST MARKET CLINICAL FOLLOW UP

Level 1 German, 2014

Anwendungs hinweise Application hints

Schnell-Start-Anleitung Quick Start Guide

Prediction Market, 28th July 2012 Information and Instructions. Prognosemärkte Lehrstuhl für Betriebswirtschaftslehre insbes.

Using TerraSAR-X data for mapping of damages in forests caused by the pine sawfly (Dprion pini) Dr. Klaus MARTIN

iid software tools QuickStartGuide iid USB base driver installation

The future of snow. The silent hero of snow guns

Efficient Design Space Exploration for Embedded Systems

Preisliste für The Unscrambler X

Initiierungs-/Korrosionsfortschritt-Sensor Initiation/Propagation-Sensor

Absaugsysteme. für Bearbeitungszentren. Extraction Systems for Machining Centers

Proposal for Belt Anchorage Points

Titanium The heaviest light metal

FOR ENGLISCH VERSION PLEASE SCROLL FORWARD SOME PAGES. THANK YOU!

Infrastructure as a Service (IaaS) Solutions for Online Game Service Provision

EtherNet/IP Topology and Engineering MPx06/07/08VRS

SERVICE INFORMATION NO. SID4-020/1

Simulation of a Battery Electric Vehicle

Algorithms for graph visualization

Transkript:

Newest Generation of the BS2 Corrosion/Warning and Measurement System BS2 System Description: BS2 CorroDec 2G is a cable and energyless system module range for detecting corrosion, humidity and prevailing potential. It is an early warning system that distinctly detecting corrosion or monitoring other damaging influences before it affect the reinforcement steel. In the following the different sensor types are described: Reading device Type A Cable- and energyless corrosion sensor

Type B Potential sensor Type C Conductivity/Humidity sensor 1.1. Type A Cable- and energyless corrosion sensor: The early warning sensor during or after concreting is attached by ordinary steel wire directly above the reinforcement steel (standard method in concrete construction). The body of the sensor is surrounded by a special wire, which will be destroyed by corrosion influences. Reading of data can be done conveniently by a small hand held, cable and energyless reading device. After the monitoring with the reading device, the user of the measurement system will get the following data: - Temperature within the concrete structure - Sensor wire 1. Level OK Yes/No - Sensor wire 2. Level OK Yes/No Special sensor solutions for concrete structures are available up to 25m of thickness. The functioning of the sensors can be checked during, before and after the process of concreting.

1.2. Type B Potential sensor: BS2 Sicherheitssysteme GmbH This type of sensor measures the potential prevailing above the reinforcement steel. The sensor is made up of a combination of precious an non-precious metals. It is attached to the reinforcement steel in the same way as sensor type A. Special designs as described for sensor type A are likewise available. Data reading is same as for type A, i. e. by a small, hand-held reading device. The system allows measuring of potential between + 100mV and 1,000mV. In addition to this, the temperature is also gauged. 3.3 Type C Conductivity/Humidity sensor: By this sensor type both, the electric conductivity and the temperature, are measured. The sensor consists of 2 stainless steel rings and is attached to the reinforcement steel just like sensor types A and B. Special designs as described for sensor types A and B are likewise available. Data reading is same as for type A and B, i. e. by a small, hand-held reading device. Installation of sensor Type C Example: Data reading by means of sensor Type C

3.4. Reader: The CorroDec sensor range is based upon the RFID principle. This being the case, the sensors don t need cabling or energy. Supply of energy comes from the RFID field of the reading device. By activating the magnetic field of the sensor, data transmission from the sensor to the reading device starts within 3 up to 5 seconds. The reading device meets following requirements: - high mechanical sturdiness - one-hand operation possible - standard operating distance for the reading device up to 10 cm - immediate indication of critical circumstances (sensor actuated/sensor OK or not OK etc.) - saving of gathered data (of up to 1,000 sensors) - wireless transmission of gathered data (WLAN) to control software (see below) The functionality of every sensor type can be checked by means of the reading device at a moment s notice: before, during and after installation. Special designs, i. e. for increasing the operation range of the reading device (max. up to 40 cm) or regarding to the design of the sensors (i. e. waterproof design) are realizable. Sample: Monitoring Software Optionally a remote scanning and connection to a control center etc. is avaible based on another BS2 system.

Appendix: BS2 Sicherheitssysteme GmbH Working principle of BS2 CorroDec corrosion sensor (type A): Technical data: - passive / energy- and cableless - Communication / energy supply by RFID principle - Ranges of communication sensor reader: - Standard-reading device: up to 10cm - Advanced-reading device: up to 40cm - Range with opt. extension unit: up to 25 meters - Self diagnostic monitoring system - Sum of information yielded: condition of sensor wires/ electrolydic resistance/potential/temperature - Diameter of sensor: 91mm - Height of sensor: 26mm - Material of sensor: Artificial resin (for standard design) Fiber concrete (for special designs) - Benefits of BS2 Systems: passive /energyless integrated self-test / self-diagnostic no cable which leave the concrete retrofittable easy to use / clear informations provided - easy to mount New: faster redout within a few seconds - - New: automatic self-test

Special designs: Installation examples: