3~ RECESSED TRACK STANDARD Ceiling cut 40 59 3~ Recessed Track Standard 41 A 5-conductor recessed track with 3 separately switchable circuits and a data bus track. It consists of an extruded aluminum profile which also functions as earth and two inserted plastic profiles carrying 4 embedded 2.5 mm 2 copper conductors. Any given profile can be easily cut to length on site. It is not necessary to cut back or bend back the copper wire. The track has pre-punched holes for mounting. They may be used within hand reach. Arrow-shaped suspensions are provided for the use with profile snap hangers. Multi Adaptors with bus contacts can use the normal 3-circuit feed. in this case there is no DALI function. 3~ recessed track standard white powder coated 2m 3m 4m 26-201 26-301 26-401 Mechanical load see p. 42 D V E Electrical connection and connection data see p. 40 m Can be cut on site Weight per meter: 1,3 kg System Components for 3~ Recessed Track Standard Live end with flange Earth contact left 99-324-1 Earth contact rights 99-325-1 Concealed live end, fits into the track profile, with cable set, terminal box and connectors 99-026-1 Concealed connector, for OEM only, without illustration 99-068-1 20 white (last digit 1) black (last digit 2) silver (last digit 3) EUTRAC 21 Mid feed 99-127-1 Electrical and mechanical straight coupler, recessed 99-038-1 Electrical straight coupler 99-332-1 L coupler, Earth contact outside 99-327-1 Earth contact inside 99-326-1 T coupler, Earth contact left 99-333-1 Earth contact right 99-328-1 X coupler, gold plated spring contacts 99-329-1 End flange with flange 99-338-1 End cap, and recessed in profile 99-036-1 Profile snap hanger for tension grip 6 pcs. 99-259-0 Suspension for M6 thread mounting 88-888-0 SYSTEM COMPONENTS FOR 3~ RECESSED TRACK STANDARD
Mon tageanlei tung -Beim Kijrzen nur das nicht Etikettierte Ende absagen. -When cutting do not cut-off fi
'G- CEe!o 4% - Die Kunststoff-Strombohn und Kupferleiter mussen um min. 2mm kurzer sein als die Alu-Schiene. Bei bauseitigem Zuschnitt entsprechend kurzen. - The plastic track and copper conductors must be shorter than the aluminium track by at least 2mm. Shorten if track is cut to length on site.
'2
V *=I x 16A 0-- :@ --+--- an. =3 x 1.5 mm 2 L _ glx. =3 x 2.5 mm 2 8 Anschlufl am Wechsektromnetz 230V (240V) Hochstbelastung : 3600W (3800W). Gesamtbelastung kann beliebig auf die 3 Stromkreise verteilt werden. Absicherung 1 x 16A. Zuleitung (min.): 3 x 1.5mm 2 (max.): 3 x 2.5mm 2 @ Anschlun am Drehstromnetz 4OOV (415V) Hochstbelastung : 3 x 3600W (3800W) = 10800W (11400W) Einzelabsicherung aller drei Phasen. Absicherung 3 x 16A. Zuleitung (min.): 5 x 1.5mm 2 (max.): 5 x 2.5mm 2 Belastbarkeit der Einspeiser: Alle Einspeiser sind geman Daten @und @belastbar. @ For 230V (240V) alternating current Maximum load: 3600W (3800W). Load can be distributed over the three circuits ot will. Fuser: 1 x 16A. Supply cable (minimum): 3 x 1,5mm 2 (maximum): 3 x 2.5mm 2 @ For 400 V (4% V) three-phase current Maximum load: 3 x 3600W (3800W) = 10800W (11400W) Each phase is separately fused., Fuse: 3 x 16A. Supply cable (minimum): 5 x 1,5mm2 (maximum): 5 x 2,5mm 2 Es liegt in dem Veranlworlungsbereich des Installateurs, die elektrische. mechanische und lhermische Verlraglichkeit zwischen dem Slromschienen- System und den daran angebrachten Leuchten sicherzustellen. Im Deckenbereich nur baupolizeilich zugelassenes Befestigungsmaterial verwenden. Mantage nur durch Fachpersonal Es ist zwingend notwendig, die Stromschienenenden mit Endabdeckung bzw. Schutzkappen zu verschliessen. 1 It is the responsibility of the inslaller to ensure the electrical, mechanical and the thermal compartiblity of the track system and Ihe Fixtures. Materials used far ceiling fixation should conform lo relevanl building regulalians. To be installed by trained personnel only It is essential to cover Ihe ends of the track with end covers or orotective coos I I