JARRELL ASH C O R P O R AT I O N

Ähnliche Dokumente
p^db=`oj===pìééçêíáåñçêã~íáçå=

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

Electrical tests on Bosch unit injectors

Electrical testing of Bosch common rail piezo injectors

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Release Notes BRICKware Copyright 23. March 2010 Funkwerk Enterprise Communications GmbH Version 1.0

Printed Circuit Board Replacement for Sievers Model PPT TOC Analyzer

Aufbaudose mit Schalter Spacing box with switch. Montageanleitung mounting instructions

ATEX-Check list. Compiled by: Date: Signature: Acceptable practice at the determination of flash point: Closed cup according to ISO 2719

OPERATING INSTRUCTIONS Test pump ZG 5.1. and ZG 5.2.

Power supply Interference suppressed acc. to DIN EN /- 4, EN 55011, EN CI. B, power factor corrected Power factor BöSha LED driver

Snap-in switch for switches PSE, MSM and MCS 30

CABLE TESTER. Manual DN-14003

Electrical testing of Bosch common rail Injectors

MultiPortSwitch. VGA Umschalter. Version 1.0 As of April 19 th 2004 Subject to change!

p^db=`oj===pìééçêíáåñçêã~íáçå=

Hazards and measures against hazards by implementation of safe pneumatic circuits

Electrical testing of Bosch common rail solenoid valve (MV) injectors

VIDEO CALL CAMERA G-VCAM-01

Electromagnetic Flowmeter FXE4000-DE43F

Finite Difference Method (FDM)

B/S/H/ Startfolie. B/S/H Bosch und Siemens Hausgeräte GmbH - KDT-T B/S/H Bosch und Siemens Hausgeräte GmbH KDT-T

Word-CRM-Upload-Button. User manual

Ingenics Project Portal

Where are we now? The administration building M 3. Voransicht

6 Schrauben 7 Schrauben

Exercise (Part V) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1

Cameraserver mini. commissioning. Ihre Vision ist unsere Aufgabe

Level 2 German, 2015

SAMPLE EXAMINATION BOOKLET

Konische Kappen und Stopfen. tapered caps & plugs. Die T-Serie war die erste Serie, die im Jahr 1948 produziert wurde.

Magic Figures. We note that in the example magic square the numbers 1 9 are used. All three rows (columns) have equal sum, called the magic number.

Datasheet. Page 1 of 7

NEWSLETTER. FileDirector Version 2.5 Novelties. Filing system designer. Filing system in WinClient

Cleaning & Disinfection of Eickview Videoendoscopes

Asynchronous Generators

MINI 1-Conductor/1-Pin Receptacle Terminal Blocks; 2-Conductor/2-Pin Receptacle Terminal Blocks, Series 2020

iid software tools QuickStartGuide iid USB base driver installation

Installation guide for Cloud and Square

Externer Temperaturfühler External temperature sensor

CLE. Heatpipe-System Kühlleistung > 30W. Heatpipe-System Kühlleistung > 25W. Heatpipe-System Kühlleistung > 25W. Heatpipe-System Kühlleistung > 20W

AU-D21. Digital Audio Optical Switcher OPERATION MANUAL

1. General information Login Home Current applications... 3

CB RADIO Service Manual AE 6890

C R 2025 C LOSE PUSH OPEN

Die Bedeutung neurowissenschaftlicher Erkenntnisse für die Werbung (German Edition)

Tube Analyzer LogViewer 2.3

Wandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply

Zehnder ComfoWell 320

Hypex d.o.o. Alpska cesta 43, 4248 Lesce Slovenija Tel: +386 (0) Fax: +386 (0)

Ein Stern in dunkler Nacht Die schoensten Weihnachtsgeschichten. Click here if your download doesn"t start automatically

BRUUDT Kennzeichenhalter für die Kawasaki Z800 BRUUDT Tail Tidy fort the Kawasaki Z800

Titelbild1 ANSYS. Customer Portal LogIn

/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.

MU-307 A SAFETY INSTRUCTIONS SICHERHEITSHINWEISE FEATURES MERKMALE

mobilcom-debitel SmartHome Schnell-Start-Anleitung Quick Start Guide

Quick Guide Home Network Mode

miditech MIDI THRU 7 MIDI THRU 7

Evidence of Performance

Kuhnke Technical Data. Contact Details

Montageanleitung Assembly Instruction Artikel: Werkstattschrank mit 2 Türen

SYSTEM COMPONENTS FOR 3~ RECESSED TRACK STANDARD 3~ RECESSED TRACK STANDARD. 3~ Recessed Track Standard

Tilt Wall. Montage- und Gebrauchsanleitung. Assembly instructions and manual.

OPERATING INSTRUCTIONS

1. Hardware Configuration Hardware-Konfiguration Software-Konfiguration Software Configuration...4

Bedienungsanleitung Operation Manual

User Manual Bedienungsanleitung. snom Wireless Headset Adapter snom Schnurlos-Headset-Adapter. English. Deutsch

Martin Luther. Click here if your download doesn"t start automatically

USBASIC SAFETY IN NUMBERS

LSA-PLUS LSA-PLUS LSA-PLUS Anlegewerkzeug Insertion tool Opzetgereedschap mit Sensor with sensor met sensor

Walter Buchmayr Ges.m.b.H.

Bedienungsanleitung SUNNYHEAT Standfuß (Art. Nr )

HEDGE TRIMMERS. eht751s eht601d

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL USER GUIDE June 2016

Profi-Pavillon / Profi Pavilion / Profiteren Paviljoen

rot red braun brown rot red RS-8 rot red braun brown R S V~

VGM. VGM information. HAMBURG SÜD VGM WEB PORTAL - USER GUIDE June 2016

Mock Exam Behavioral Finance

Installation Instructions

ITAC Bedienungsanleitung User manual. Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren.

PONS DIE DREI??? FRAGEZEICHEN, ARCTIC ADVENTURE: ENGLISCH LERNEN MIT JUSTUS, PETER UND BOB

Installation manual / Montageanleitung WBC2 splice patch with Fibertray Spleissung/Rangierung mit Fibertray

AKTIVE DVB-T ZIMMERANTENNE ANSCHLUSSHINWEISE ACTIVE DVB-T INDOOR ANTENNA CONNECTION INSTRUCTIONS

Anschlussadapterset SWR-MC

Einbau- und Montageanleitung Wanddurchführungs-Set Seite 3-4 Assembly instructions and mounting guide Wall pipe set Page 5-6

Exercise (Part II) Anastasia Mochalova, Lehrstuhl für ABWL und Wirtschaftsinformatik, Kath. Universität Eichstätt-Ingolstadt 1

PONS DIE DREI??? FRAGEZEICHEN, ARCTIC ADVENTURE: ENGLISCH LERNEN MIT JUSTUS, PETER UND BOB

Notice: All mentioned inventors have to sign the Report of Invention (see page 3)!!!

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 0607 WRD-H 0805 WRD-H 1208 WRD-H 1610 WRD-H

Zehnder ComfoWell 220

Bedienungsanleitung Thermodrucker User Manual Thermal printer

MQ964..GB MQ965..GB. en Operating instructions ar

Ölmess-Stäbe-Satz für Motor und Automatikgetriebe Mercedes-Benz

Einbauanleitung / Installation Instructions Kit CM44xR

Universe Square Suspension

Montageanweisung Mounting Instructions

Ölmess-Stäbe-Satz für Motor und Automatikgetriebe Mercedes-Benz

Produktinformation _185PNdeen

Transkript:

ATOMSCAN ADVANTAGE Safety Guide PART NUMBER 14096600 USE OF PUBLICATION OF DATA: THIS MANUAL CONTAINS PROPRIETARY DOCUMENTS INTENDED FOR THE EXCLUSIVE USE OF THERMO JARRELL ASH CUSTOMERS AND THERMO JARRELL ASH PERSONNEL AND MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING AND RECORDING, FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF THERMO JARRELL ASH. TRADEMARKS: THE THERMO JARRELL ASH LOGO IS A REGISTERED TRADEMARK OF THERMO JARRELL ASH. THERMO JARRELL ASH C O R P O R AT I O N 27 FORGE PARKWAY FRANKLIN, MA 02038 TEL: 508-520-1880 FAX: 508-520-1732 A SUBSIDIARY OF THERMO OPTEK CORPORATION

Atomscan Advantage Sequential Inductively Coupled Plasma Emission Spectrometer Safety Guide Part Number: 140966-00 Printed: 31 March 1998 Copyright 1998 All Rights Reserved Published in the USA Thermo Jarrell-Ash Corporation Tel: (508)520-1880 27 Forge Parkway Franklin, MA 02038 Fax: (508)520-1732 Telex: 174230 TJAUT A subsidiary of Thermo Optek Corp.

This page intentionally left blank jl Page 2 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

Due to design changes and product improvements, the information in this document is subject to change without notice. Thermo Jarrell-Ash (TJA) reserves the right to change hardware and/or software design which may subsequently affect the contents of this operator's manual. Thermo Jarrell-Ash assumes no responsibility for any errors that may appear in this operator's manual. *** SAFETY WARNING *** The methods and analytical procedures described in this and other manuals supplied with your TJA Atomscan Advantage ICAP Spectrometer are designed to be carried out by properly trained personnel in a suitably equipped laboratory. In common with many laboratory procedures, the methods described may involve hazardous materials or substances of unknown toxicity. For the correct and safe execution of the methods, it is essential that laboratory personnel follow standard safety procedures for the handling of hazardous materials. While the greatest care has been exercised in the preparation of this information, Thermo Jarrell Ash expressly disclaims any liability to users of these procedures for consequential damages of any kind arising out of or connected with the use of these procedures. There are many sources of safety information available. Consult your chemical and laboratory supply catalogs. You may also refer to the CRC Handbook of Laboratory Safety, published by CRC Press, Inc., Boca Raton, Florida. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 3

This page intentionally left blank I Page 4 Atomscan Advantage Plasma Emission Spectrometer Safety Cuide j

Table of Contents Table of Contents 5 List of Figures 7 Explanation of Symbols 9 Inductively Coupled Plasma Emission Spectroscopy 13 Introduction 13 Atomscan Advantage Emission Source 14 Plasma Igniter 15 Mercury Lamp 17 Electrical Requirements 18 Mains Circuit Breaker 20 RF Generator 21 RF Generator Air Filter 21 Service Connections 23 Computer Connection 24 Cooling the Plasma Coil 24 Waste Removal 25 Venting Requirements-Radial Plasma 26 Venting Requirements-Axial Plasma 28 Waste Handling Requirements 29 CE Declaration of Conformity.. 29 Weight and Dimensions...30 Weight 31 \Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 5 \

I This page intentionally left blank Page 6 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

List of Figures Figure 1: Lethal Voltage Hazard Label 9 Figure 2: Vision Hazard Warning Symbol 10 Figure 3: Electrical Hazard Warning Symbol 10 Figure 4: Seek Further Information Symbol 10 Figure 5: Ground Hazard Warning Symbol 11 Figure 6: Hot surface warning symbol 11 Figure 7: Schematic of an Inductively Coupled Plasma... 14 Figure 8: ICAP Torch 15 Figure 9: Radial Plasma Compartment 16 Figure 10: Radial Plasma Torch Compartment, Open 17 Figure 11: Axial Plasma Torch Compartment 17 Figure 12: Mains power cord location 18 Figure 13: Power Cable Color Scheme 19 Figure 14: Atomscan Advantage side panel showing the main power circuit breaker 20 Figure 15: Atomscan Advantage rear view showing RF Generator 21 Figure 16: Locating the monochromator cover locking screw 22 Figure 17: Holding the monochromator cover in the raised position 22 Figure 18: Removing the RF generator filter 23 Figure 19: Service Connections to Rear of Instrument 23 Figure 20: Computer connection cable 24 Figure 21: Coolant reservoir on rear panel 24 Figure 22: Recommended Drain Configuration 25 Figure 23: Vent connection on the Atomscan Advantage 27 Figure 24: Vent connection on the Atomscan Advantage 28 Figure 25: Atomscan Advantage-Front view 30 Figure 26: Atomscan Advantage- Side view 30 Figure 27: Atomscan Advantage- Top view 31 Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 7

This page intentionally left blank Page 8 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

Explanation of Symbols There are several symbols used throughout this text and in labels attached to various parts of the Atomscan Advantage ICP Spectrometer. These labels caution against known hazards or require you to read and familiarize yourself with standard operating procedures for given circumstances. In cases where these circumstances are well documented but beyond the scope of this manual, detailed references are provided. This section of the Safety Guide documents the labeling used on the Atomscan Advantage Spectrometer and in this manual. The "matchbox" transfers the RF signal from the generator to the work coil within which the plasma is created. The internal workings of this device are potentially lethal. Unauthorized entry may result in death. This label will be found on the rear panel of the matchbox. There are no user serviceable parts inside. On no account should the user remove any panels bearing this label. LETHAL voltages present insllll No user serviceable ppt$ wifflp^ Removal of pane! and access tp electronics should be dorse by l p trained and certified personnel os^: Figure 1: Lethal Voltage Hazard Label Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 9

This symbol is found in this manual to warn of UV radiation that is harmful to the eyes. This radiation is produced by the plasma and, during normal operation is screened by both the outer door to the sample compartment and by an inner, interlocked door which provides access to the torch and work coil. Removal of this inner door will immediately cause the plasma to be extinguished. Under no circumstances should any attempt be made to defeat the interlocks. Figure 2: Vision Hazard Warning Symbol This label is used on the instrument and in this manual to identify warnings having to do with electrical hazards. Figure 3: Electrical Hazard Warning Symbol This symbol is used on the instrument and in this manual to identify hazards which require further information. Such information is generally available, either in the immediately preceding and/or following section of this manual or in standard texts to which reference is provided. Figure 4: Seek Further Information Symbol Page 10 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

This symbol is used to identify a hazard which requires electrical grounding to eliminate. The integrity of the electrical ground should always be checked by an authorized TJA service engineer whenever there is a change in electrical connections. Figure 5: Ground Hazard Warning Symbol This symbol is used to identify surfaces that may become hot enough to cause discomfort or burn injury if touched. Exercise extreme caution before touching any surface bearing this symbol. Figure 6: Hot surface warning symbol Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 77

This page intentionally left blank Page 12 Atom scan Advantage Plasma Emission Spectrometer Safety Guide

Inductively Coupled Plasma Emission Spectroscopy Warning THE PLASMA EMITS INTENSE ULTRA-VIOLET RADIATION WHICH CAN CAUSE PERMANENT DAMAGE TO VISION. NEVER LOOK AT THE PLASMA WITHOUT EYE PROTECTION. THE OPERATOR IS PROTECTED BY AN OUTER DOOR AS WELL AS AN INNER DOOR WHICH IS INTERLOCKED. IF THE INNER DOOR IS OPENED, THE PLASMA WILL EXTINGUISH. NEVER ATTEMPT TO DEFEAT ANY INTERLOCKS. Introduction Inductively coupled plasma spectroscopy is a technique for the determination of metallic, semi-metallic and some non-metallic elements by atomic emission spectroscopy. An inductively coupled plasma is an electrical discharge formed in a stream of argon gas flowing through a series of concentric quartz tubes surrounded by a coil. This coil is attached to a relatively powerful radio frequency generator. During plasma ignition, the gas stream is seeded with electrons from an external source, such as a small spark. These electrons are accelerated in a toroidal path by the RF electromagnetic field, and collide with argon atoms to form more electrons and argon ions, which are in turn accelerated. This process continues until the gas becomes highly ionized (a plasma), at which point the discharge is stable and self-sustaining as long as the RF field is applied. The temperature within this toroidal plasma is as high as 10,000 degrees K. The plasma and the torch are shown schematically in the following figure. \Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 13

Concentric Quartz Tubes Figure 7: Schematic of an Inductively Coupled Plasma Liquid samples are introduced into the plasma discharge as an aerosol suspended in argon gas. This sample aerosol is carried through the center tube of the three quartz tubes comprising the torch assembly. The sample aerosol stream passes through the center of the toroidal plasma discharge, where it is desolvated, atomized, and the resultant element atoms and ions are excited. After excitation, the atoms comprising the sample emit light at their characteristic wavelengths. This light is transmitted by the optical system to the detector. Atomscan Advantage Emission Source The Atomscan Advantage spectrometer's emission source is an Inductively Coupled Argon Plasma (ICAP). The ICAP source is powered by a fully solid state 2kW crystal-controlled radio frequency (RF) generator operating at 27.12 MHz. The output from the RF generator is coupled to a water-cooled copper induction coil that wraps around the outside of the quartz torch assembly. Argon gas flows through the torch assembly as shown in the next figure. The largest flow of argon (the coolant flow), typically 15 L/minute, passes between the outer and intermediate tubes of the torch. Smaller gas flows pass between the intermediate and center tube (auxiliary flow), typically 0 to 2 L/minute and through the center tube (sample flow), typically 0.6 to 1 L/minute. Page 14 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

Sample Flow Auxiliary Coolant Flow Main Coolant Flow (Plasma Gas) Figure 8: ICAP Torch The next figure shows the induction coil wrapped around the radial torch. The piezoelectric igniter which supplies the spark to seed the argon gas with electrons during ignition is embedded in the auxiliary gas delivery tube. This is the black tube leading from the bulkhead fitting to the lower connection on the torch assembly. The metal parts of the these connectors are protected with insulating covers. A fiber optic light pipe which monitors the plasma is located inside the torch compartment. Its function is to shut down the RF supply and provide an error message if the plasma is extinguished. The argon gas lines connected to the nebulizer, outer torch coolant flow, and inner auxiliary flow are also shown. These gas lines are connected to the torch and to the base of the torch compartment with quick-disconnect fittings. The figure also shows the faceplate, complete with protective dark glass window that covers the plasma discharge box and shields the operator from UV light and RF radiation. Four thumbscrews hold this faceplate in place. This faceplate is interlocked by the two diagonally opposite screws. If one of these two faceplate screws is loosened, the RF generator shuts off, and the plasma stops running. Plasma Igniter A wire which runs through the auxiliary gas supply tubing provides the high voltage (30,000 V) spark required for plasma ignition. This tubing is fitted with an insulating sleeve, which must be used to cover the metal gas connector on the body of the torch. When removing the torch, carefully remove the sleeve by gently twisting it while pulling it off the connector. Always be sure to replace the insulating sleeve when reattaching the auxiliary tubing to the torch. The position of the insulating sleeve is shown in the next two figures. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 15

Interlocked cover retaining screws. Faceplate must be in place to ignite plasma Insulating sleeve Figure 9: Radial Plasma Compartment k-k-k WARNING *** DIRECTLY VIEWING THE PLASMA SOURCE CAUSES PERMANENT EYE INJURY. DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO VIEW THE PLASMA EXCEPT THROUGH THE TREATED GLASS WINDOW ON THE INTERLOCKED FACEPLATE. DO NOT ATTEMPT TO DEFEAT ANY INTERLOCKS. The next figure shows the radial torch compartment with the front cover removed. The fiber optic that views the plasma will be seen in the middle of the plate that secures the coil to the rear wall of the matchbox. Page 16 Atomsccm Advantage Plasma Emission Spectrometer Safety Guide

' " " j % _. V *. ' it / * A '... '.. _«-..«- UAJUUU Figure 10: Radial Plasma Torch Compartment, Open The next figure shows the sample compartment of the Atomscan Advantage Axial ICAP Spectrometer. Except for the axially positioned torch, it is identical to the radial instrument. Mercury Lamp Figure 11: Axial Plasma Torch Compartment The mercury lamp is used for wavelength calibration of the instrument. It moves into place automatically when required, allowing light to pass from the lamp into the entrance slit. The lamp is only on when in use, so that it is unlikely to require replacement in normal use. The Hg lamp is not user serviceable. Light from the mercury lamp is not normally visible through the enclosure. If there are any problems, or if any blue mercury light can be seen in the area where the optical transfer tube, contact your authorized TJA service representative. \ Atom scan Advantage Plasma Emission Spectrometer Safety Guide Page 17 \

*** WARNING *** DIRECTLY VIEWING THE MERCURY LAMP CAUSES PERMANENT EYE INJURY. DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO OPEN THE MERCURY LAMP HOUSING. IF SERVICE IS REQUIRED, CONTACT AN AUTHORIZED TJA SERVICE REPRESENTATIVE. Electrical Requirements *** CAUTION *** DO NOT PLUG IN YOUR ATOMSCAN ADVANTAGE. WAIT FOR YOUR TJA SERVICE ENGINEER TO CHECK ALL ELECTRICAL SUPPLIES. IN ORDER TO PREVENT INJURY OR DEATH FROM ACCIDENTAL CONTACT WITH HIGH VOLTAGES, DO NOT REMOVE ANY OF THE COVERS FROM YOUR ATOMSCAN ADVANTAGE SPECTROMETER. The power supply unit, located in the lower section of the cabinet is equipped with an 8 foot (2.4 meter) power cord, so the electrical outlet that you supply must be within 8 feet (2.4 m) of the rear of the power unit. This is shown in the next figure. Mains power cord Figure 12: Mains power cord location Page 18 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

The voltages available for the Atomscan Advantage ICAP Spectrometer are 200, 208,220, and 240V at 50/60 Hz and single phase. A dedicated line of 30 amp is required from the main transformer. This line must maintain the required voltage under loaded conditions and must accommodate the current surge during power-up. Satisfactory analytical performance is obtained over ±10 % line voltage fluctuations if analyzing aqueous solutions, and over +10 to -5 % line voltage fluctuations if analyzing organic solutions. *** CAUTION *** THE ATOMSCAN ADVANTAGE IS CONSIDERED A HIGH LEAKAGE CURRENT DEVICE (4.3 MILLIAMPS). MAKE SURE THAT THE NON-CURRENT CARRYING SAFETY GROUND MEETS ALL ELECTRICAL CODE REQUIREMENTS, THUS MINIMIZING GROUND IMPEDANCE. The main spectrometer power cable is shown in the next figure. This must be hard wired directly to the power supply or, alternatively, a plug meeting local codes may be used. Outside the USA, no plug is provided on this cord. Brown (Live) VOLT I Blue (Neutral) Green/Yellow NON-CURRENT CARRYING GROUND Figure 13: Power Cable Color Scheme Grounding is necessary in all spectrometer systems. The safety ground (green wire with yellow stripe) connected to the power unit is an acceptable ground provided it meets the following National Electrical Code requirements: 1. The ground (green/yellow) wire should be a non-current carrying equipment ground. 2. The wire is connected to an earth ground stake (located at the service entrance of building) or a dedicated ground grid. 3. It is not terminated anywhere into the main power line or into questionable grounded media such as water pipes, conduit pipes, or building "I" beams. 4. Do not connect this equipment wire to the neutral conductor except at the service panel box or isolation transformer. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 19

The computer and printer as supplied with the instrument are set to operate at local line voltage and receive their power from a wall outlet. No printer is supplied with 220,230 or 240 V systems. Mains Circuit Breaker The mains circuit breaker is located on the right side of the instrument, as viewed from the front. The next figure shows the right side panel of the Atomscan Advantage. Figure 14: Atomscan Advantage side panel showing the main power circuit breaker The red circuit breaker near the rear of the panel is the main power control. It is ON when in the UP position (T) and OFF when in the DOWN position (0). To the left of the main circuit breaker is a small additional circuit breaker. This protects the 115 V feed from the main transformer secondary to the low voltage power supplies. Page 20 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

RF Generator *** Warning *** THE RF GENERATOR SHOULD NEVER BE OPENED OR UNCOVERED BY UNAUTHORIZED PERSONNEL. IT CONTAINS POTENTIALLY FATAL VOLTAGES THAT CAN CAUSE SEVERE INJURY OR DEATH. The RF generator is located in the center of the lower portion of the Atomscan Advantage cabinet. It is regulated to accommodate a ± 10% variation in the nominal input voltage. This module generates the RF energy that sustains the plasma. The next figure shows a rear view of the Atomscan Advantage, with the RF generator visible in the center of the lower chassis. RF Generator Circuit Breaker Figure 15: Atomscan Advantage rear view showing RF Generator The RF generator is equipped with its own circuit breaker, which you should never use in normal operation. If this breaker should ever trip, call your authorized TJA service representative immediately. Do not reset it yourself. Tripping of this breaker indicates a serious problem within the generator. RF Generator Air Filter Under normal circumstances, the air filter for the RF generator should be cleaned every 6 months. In dusty environments, this may require more frequent attention. Proceed as follows. SHUT OFF THE INSTRUMENT. Turn off the main circuit breaker on the right side of the instrument. Open the plasma compartment door and locate the screw that holds the cover of the monochromator compartment closed. This is shown in the next figure. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 21

Figure 16: Locating the monochromator cover locking screw. Remove the screw and raise the monochromator cover. Use the prop rod to keep it in the raised position as shown in the next figure. Be sure to insert the end of the prop rod into the hole to ensure that the cover remains stable. Figure 17: Holding the monochromator cover in the raised position. Locate the filter. It is mounted in a metal carrier which can be identified by the two holes. Insert a thumb and finger into these holes and pull the filter out as shown in the next figure. Page 22 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

Figure 18: Removing the RF generator filter Remove the two screws holding the filter element in place, and remove the element. Blow out the dust with compressed air. Alternatively, wash the filter element, then dry it thoroughly before replacing it in the holder. Replace the filter in the instrument. Ensure that the holder is correctly placed in the guide slots, then push it firmly down until it is fully seated. Service Connections Service connections for inert gas and power are on the rear of the instrument, as shown in the next figure: Plasma gas Purge gas Heat Exchanger for Water Recirculator Figure 19: Service Connections to Rear of Instrument Connect argon for the plasma to the LEFT fitting (as viewed from the rear) and nitrogen for the purge gas to the RIGHT fitting. If you wish to use argon for both purge and plasma gas, you may use a "T" to connect both inlets to the same gas supply line (as is shown in the illustration). Teflon or copper tubing should be used for the gas supply. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 23

Computer Connection The Atomscan Advantage is connected to the host computer by a serial cable, which is plugged into the 9 pin Sub-D socket on the left side of the instrument (as seen from the front). This is shown in the next figure. Host computer connection Cooling the Plasma Coil Figure 20: Computer connection cable Cooling water for the induction coil is provided by a built-in recirculation system. A reservoir is located on the rear panel, just to the left of the exhaust duct (as viewed from the rear of the instrument). It is readily accessed from the right side. The reservoir is shown in the next figure. Figure 21: Coolant reservoir on rear panel Check this reservoir every day to ensure that the water level is near the Max mark. To refill the reservoir, lift the metal carrier to disengage it from the slots. Remove the bottle and, holding the cap, unscrew the bottle by turning it counterclockwise. Alternatively, disconnect the lines by pressing the locking tab on each one in turn and removing the coolant line. Then, with the bottle still in place, unscrew the cap. Fill the bottle with distilled water. Note that the two fittings are different, so that you cannot confuse the inlet and outlet when replacing them. A third way to fill the bottle is to use a wash bottle with a fine nozzle to squirt water through the vent hole, which is found between the two fittings. Page 24 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

Waste Removal Waste is removed from the Atomscan Advantage using one channel of the 4 channel peristaltic pump. The drain line exits from the side of the instrument to the 9-liter bottle that is supplied with the instrument It should be placed on the floor to the right side of the instrument. A small hole, just large enough for the capillary tube to pass through should be bored through the bottle cap. The cap should remain on the waste bottle at all times except when it is being emptied. Pumping the drain is a convenient way of removing waste without the operator having to be concerned with smooth operation of a gravity drain. Figure 22: Recommended Dram Configuration Place marble chips in the drain bottle to neutralize most of the acids deposited into the container. This helps to minimize the release of acid fumes from the waste container. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 25

*** WARNING *** SAMPLES CAN CONTAIN HIGH LEVELS OF ACIDS WHICH MAY BE CORROSIVE AND WHICH MAY PASS HARMFUL VAPORS INTO THE AIR IF PROPER PRECAUTIONS ARE NOT TAKEN. CONSULT AN APPROPRIATE LABORATORY SAFETY HANDBOOK FOR PROPER STORAGE/DISPOSAL PROCEDURES. ONE SUCH PUBLICATION IS THE CRC HANDBOOK OF LABORATORY SAFETY. PUBLISHED BY CRC PRESS, INC., BOCA RATON, FLORIDA. Venting Requirements- Radial Plasma During operation, the torch exhaust gases must be vented in order to prevent the introduction of potentially poisonous or corrosive materials into the laboratory air. The vent must also be on at all times to ensure adequate heat removal from the torch compartment. The torch exhaust is immediately above the plasma discharge, from where it is directed to the rear panel of the instrument. The vent is interlocked by both a flow sensor in the duct and by a thermal sensor in the torch compartment. These interlocks are in addition to the two faceplate interlock switches. If any of these interlocks are interrupted, an error message will appear in the Plasma status panel and the plasma, if it is on, will extinguish. The venting system must be capable of drawing 150 cubic feet/min. (4.2 m 3 /min), at the instrument and the ducting material should be stainless steel. A satisfactory blower and vent assembly is available from TJA as part number xxxxxxxx for 115V/60 Hz, as xxxxxxxx for 220V/60 Hz, and as number xxxxxxxx for 220V/50 Hz. To install your venting system, use sheet metal screws, or silver solder to connect the vent components. DO NOT USE SOFT, LEAD-TIN SOLDER. If your vent system is connected into a chemical hood duct, take special care to prevent acid fumes from back flowing into the spectrometer. The RF generator is vented from the lower rear center of the cabinet, as shown in the next figure. The all solid state generator does not generate sufficient heat to warrant a separate vent. Page 26 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

Figure 23: Vent connection on the Atomscan Advantage TJA Service Engineers are not permitted to install blower and vent assemblies. Check with your local building inspector regarding ordinance requirements for vent systems. The torch vent assembly can be seen inside the sample compartment. Note that there are accessible surfaces that can become very hot. These are identified by the warning symbol, as shown in the next figure. *** WARNING *** THE UPPER PORTION OF THE TORCH BOX VENT ASSEMBLY IS ACCESSIBLE INSIDE THE SAMPLE COMPARTMENT. IT CAN BECOME HOT ENOUGH TO CAUSE BURN INJURY. DO NOT TOUCH THE HOT SURFACES OF THE VENT ASSEMBLY WHICH ARE IDENTIFIED BY THIS SYMBOL. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 27

Venting Requirements- Axial Plasma During operation, the torch exhaust gases must be vented in order to prevent the introduction of potentially poisonous or corrosive materials into the laboratory air. The vent must also be on at all times to ensure adequate heat removal from the torch compartment. The torch exhaust is immediately above the plasma discharge, from where it is directed to the rear panel of the instrument. The vent is interlocked by both a flow sensor in the duct and by a thermal sensor in the torch compartment. These interlocks are in addition to the two faceplate interlock switches. If any of these interlocks are interrupted, an error message will appear in the Plasma status panel and the plasma, if it is on, will extinguish. The venting system must be capable of drawing 170 cubic feet/min (4.7 m 3 /min) at the instrument. The ducting material should be stainless steel. To install your venting system, use sheet metal screws or silver solder to connect the vent components. DO NOT USE SOFT, LEAD-TIN SOLDER. If your vent system is connected into a chemical hood duct, take special to prevent acid fumes from flowing back into the spectrometer. The RF generator is vented from the lower rear center of the cabinet, as shown in the next figure. The all solid state generator does not generate sufficient heat to warrant a separate vent. Figure 24: Vent connection on the Atomscan Advantage TJA Service Engineers are not permitted to install blower and vent assemblies. We recommend that you check with your local building inspector regarding ordinance requirements for vent systems. The torch vent assembly can be seen inside the sample compartment. Note that there are accessible surfaces that can become very hot. These are identified by the warning symbol, as shown in the next figure. Page 28 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

*** WARNING *** THE UPPER PORTION OF THE TORCH BOX VENT ASSEMBLY IS ACCESSIBLE INSIDE THE SAMPLE COMPARTMENT. IT CAN BECOME HOT ENOUGH TO CAUSE BURN INJURY. DO NOT TOUCH THE HOT SURFACES OF THE VENT ASSEMBLY WHICH ARE IDENTIFIED BY THIS SYMBOL. Waste Handling Requirements The Atomscan Advantage features a pumped drain, so that there is no drain trap and no need to partially fill the waste bottle to form a liquid trap. Waste is pumped through a capillary tube attached to the outlet of the spray chamber. Collect the waste sample in the bottle supplied with the spectrometer. Place this waste bottle at the right of the instrument below the sample shelf. It is recommended that you bore a very small hole in the lid of the bottle, just large enough for the capillary to fit through. Neutralize any acidic waste by placing marble chips into the waste bottle; this procedure prevents acid fumes from escaping into the laboratory atmosphere. It is your responsibility to dispose of the accumulated waste in a safe and responsible manner. *** WARNING *** WASTE SOLUTIONS CAN CONTAIN HIGH LEVELS OF ACIDS WHICH MAY BE CORROSIVE AND WHICH MAY PASS HARMFUL VAPORS INTO THE AIR IF PROPER PRECAUTIONS ARE NOT TAKEN. CONSULT AN APPROPRIATE LABORATORY SAFETY HANDBOOK FOR PROPER STORAGE/DISPOSAL PROCEDURES. ONE SUCH PUBLICATION IS THE CRC HANDBOOK OF LABORATORY SAFETY. PUBLISHED BY CRC PRESS, INC., BOCA RATON, FLORIDA. CE Declaration of Conformity TJA instruments conforming to CE requirements can be identified by the CE label on the rear panel next to the serial number. Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 29

Weight and Dimensions 27.0 in 686 mm u Figure 25: Atomscan Advantage- Front view 4.3 in 110mm (Removable) Figure 26: Atomscan Advantage- Side view Page 30 Atomscan Advantage Plasma Emission Spectrometer Safety Guide

50.5 in 1283 mm Figure 27: Atomscan Advantage- Top view Weight Atomscan Advantage Computer (incl. standard monitor and printer, but NOT incl. a table) 375 lbs 45 lbs 167 kg 20 kg Atomscan Advantage Plasma Emission Spectrometer Safety Guide Page 31

Atomscan Advantage Sequentieel inductief gekoppeld plasma emissie spectrometer Veiligheids Handleiding Part Number: 140966-00 Gcdrukt: 31 maart 1998 Copyright 1998 Alle rcchten voorbchouden Uitgegeven in de Verenigde Staten Thermo JarreH-Ash Corporation Tel: (508)520-1880 27 Forge Parkway Franklin, MA 02038 Fax: (508)520-1732 Telex: 174230 TJAUT A subsidiary of Thermo Optek Corp.

I Deze pagina is opzettelijk leeg gelaten. I Pagina 2 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

De informatie in dit document is onderhevig aan veranderingen zonder voorafgaande waarschuwing, ten gevolge van ontwerp veranderingen en produkt verbeteringen Thermo Jarrell Ash (TJA) behoudt zich het recht voor om veranderingen aan het produkt en de software door te voeren die mogelijk de inhoud van dit gebruikers handleiding beinvloeden. Thermo Jarrell Ash neemt geen verantwoordelijkheid voor mogelijke fouten in deze gebruikers handleiding. *** VEILIGHEIDS WAARSCHUWING *** De methoden en analytische procedures die in dit en andere gebruikers handleidingen, meegeleverd met de TJA IRIS Advantage Spectrometer, zijn ontworpen om uitgevoerd te worden door geschoold personeel in een toegerust laboratorium. In analogie met vele laboratorium procedures, kunnen materialen en substanties noodzakelijk zijn waarvan de giftigheid onbekend is. Voor een juiste en veilige uitvoering van de methoden, is het noodzakelijk dat het laboratorium personeel standaard veiligheids procedures in acht nemen voor wat betreft het gebruik van gevaarlijke materialen. Tenvijl de grootste zorg is genomen in het samenstellen van deze informatie, neemt Thermo Jarrell Ash uitdrukkelijk geen verantwoordelijkheid ten op zichte van de gebruikers van deze procedures voor schade die zou kunnen ontstaan als gevolg van het gebruik van deze procedures. Er zijn vele bronnen voor het verkrijgen van veiligheids informatie. Raadpleeg uw catalogi voor laboratorium benodigdheden. U kan ook het CRC Handboek voor Laboratorium Veiligheid (CRC Handbook for Laboratory Safety), uitgegeven door CRC Press, Inc., Boca Raton, Florida, raadplegen. Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pagina 3

Deze pagina is opzettelijk leeg gelaten. I Pagina 4 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Inhoudsopgave Inhoudsopgave...5 Lijst van Figuren 7 Verklanng van de symbolen 9 Inductief Gekoppeld Plasma Emissie Spectrometrie 13 Atomscan Advantage Emissie Bron 14 KwikLamp 17 Electrische Aansluitingen 18 Hoofdschakel 20 RF Generator 21 RF Generator Lucht Filter 21 Service Aansluitingen 23 Computer Aansluiting 24 Koeling van de Plasma spoel 24 Afval verwijdering '. 25 Afeuig specificaties- Radiaal Plasma 26 Afeuig specificaties-axiaal Plasma 28 Benodigdheden t.b.v afval behandeling 29 Verklanng van confirmatie aan CE 29 Gewichten en Dimensies 31 Gewicht.. 32 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pagina 5

Deze pagina is opzettelijk leeg gelaten. Pagina 6 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Lijst van Figuren Figuur 1: Dodelijke Spanning Gevaar Waarschuwings Label...9 Figuur 2: Zicht Waarschuwings Symbool. 10 Figuur 3: Elektrisch gevaar waarschuwings label 10 Figuur 4: Zoek verder informatie symbool 11 Figuur 5: Aarding gevaar waarschuwings symbool 11 Figuur 6: Schema van een inductiefgekoppeld plasma 14 Figuur 7: ICAP Toorts 15 Figuur 8: Radiaal Plasma Compartiment 16 Figuur 9: Radiaal Plasma Toorts Kamer, Open 17 Figuur 10: Axiale Plasma Toorts Kamer 17 Figuur 11: Netsnoer positie 18 Figuur 12: Netsnoer kleur code 19 Figuur 13: Atomscan Advantage zijpaneel welke de netspannings hoofdschakelaar toont 20 Figuur 14: Atomscan Advantage achterkant welke de RF Generator toont 21 Figuur 15: Locatie van de monochrornator deksel bevestigings schroef. 22 Figuur 16: Het monochromator deksel in opgeheven positie 22 Figuur 17: Verwijdering van het RF generator filter 23 Figuur 18: Service aansluitingen aan de achterkant van het instrument... 23 Figuur 19: Computer aansluit kabel 24 Figuur 20: Koeling reservoir op het achter paneel 24 Figuur 21: Aanbevolen afvoer configuratie 25 Figuur 22: Ventilatie aansluiting van de Atomscan Advantage 27 Figuur 23: Ventilatie aansluiting op de Atomscan Advantage 28 Figuur 24: Atomscan Advantage-Voor aanzicht 31 Figuur 25: Atomscvan Advantage- Zij aanzicht 31 Figuur 26: Atomscan Advantage- Boven aanzicht 32 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pag'ma 7

Deze pagina is opzettelijk leeg gelaten. Pagina 8 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Verklaring van de symbolen Er worden verschillende symbolen gebruikt in deze tekst en op labels op verscheidene onderdelen van de Atomscan Advantage ICP spectrometer. Deze labels waarschuwen voor bekende gevaren of eisen van u dat u de standaard bedienings voorschriften leest en u zich daarmee bekend maakt voor bepaalde omstandigheden. In de gevallen waar deze omstandigheden goed zijn omschreven maar buiten de doelstelling van deze handleiding vallen, worden gedetailleerde referenties gegeven. Dit hoofdstuk van de veiligheids handleiding beschrijft de labels zoals die gebruikt worden op de Atomscan Advantage Spectrometer en in deze handleiding. De 'matchbox' zend het RF signaal naar de spoel waarin het plasma gecreeerd wordt. De interne werking van deze eenheid zijn mogelijkerwijs levensgevaarlijk. Niet geautoriseerde toegang kan de dood tot gevolg hebben. Dit label wordt gevonden op de achterkant van de 'matchbox', Er zijn geen onderdelen binnenin die door de gebruiker onderhouden kunnen worden. Onder geen beding moet de gebruiker panelen met dit label verwijderen. LETHAL voltages present irislcpk No user serviceable parts within,;; Removal of panel and access to the electronics should be done by TvS: trained and certified personnel orily; Figuur 1: Dodelijke Spanning Gevaar Waarschuwings Label Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pagina 9

Dit symbool wordt in deze handleiding gevonden om te waarschuwen tegen UV straling die schadelijk is voor de ogen. Deze straling wordt door het plasma geproduceerd en wordt gedurende normaal gebruik afgeschermd door zowel de buitenste toegangs deur tot het monster compartiment als door een binnenste, die beveiligd is en toegang geeft tot de spoel en toorts. Verwijdering van de binnenste deur heeft het onmiddellijk doven van het plasma tot gevolg. In geen enkel geval zou geprobeerd moeten worden om de beveiligingen buiten werking te stellen. Figuur 2: Zicht Waarschuwings Symbool Dit label wordt in deze handleiding gebruikt om waarschuwingen aan te duiden die met gevaar van elektriciteit te maken hebben. Figuur 3: Elektrisch gevaar waarschuwings label Paging 10 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Dit symbool wordt in deze handleiding gebruikt om gevaren aan te duiden die verdere informatie behoeven. Dit soort informatie is over het algemeen beschikbaar in het onmiddellijke vervolg van deze handleiding en/of volgend hoofdstuk van deze handleiding of in de standaard teksten die genoemd worden. Figuur 4: Zoek verder informatie symbool Dit symbool vvordt in deze handleiding gebruikt om gevaren aan te duiden die verdere informatie behoeven. Dit soort informatie is over het algemeen beschikbaar in het onmiddellijke vervolg van deze handleiding en/of volgend hoofdstuk van deze handleiding of in de standaard teksten die genoemd worden.. Figuur 5: Aarding gevaar waarschuwings symbool Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Paging 77

I Deze pagina is opzettelijk leeg gelaten, Pagina 12 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Inductief Gekoppeld Plasma Emissie Spectrometrie *** WAARSCHUWING *** Het plasma emitteert een intense ultraviolette straling die blijvende schade aan het gezichtsvermogen kan veroorzaken. Kijk nooit rechtstreeks in het plasma zonder enige bescherming van de ogen. De gebruiker wordt beschermd door een buiten en een binnen deur die beveiligd is. AIs de binnen deur geopend wordt, dooft het plasma. Probeer nooit beveiligingen onklaar te ma ken. Introductie Inductief gekoppeld plasma spectrometrie is een techniek voor de bepaling van metallische, semimetallische en enkele niet metallische elementen door middel van atomaire emissie spectrometrie. Een inductief gekoppeld plasma is een elektrische ontlading die gevormd wordt in stroom van argon gas door een aantal concentrische kwarts buizen, omringd door een spoel. Deze spoel is verbonden aan een relatief krachtige Radio Frequence generator. Gedurende het opstarten van het plasma, wordt de argon stroom geladen met elektronen van een externe bron, bijvoorbeeld een kleine vonk. Deze elektronen worden versneld in een toroidale weg door het RF elektromagnetische veld en die botsen met argon atomen om zodoende meer vrije elektronen en argon ionen te vormen, die op him beurt weer versneld worden. Dit proces gaat door totdat het gas in hoge mate geioniseerd is (een plasma) waarbij de ontlading stabiel en zelf onderhoudend wordt zolang het RF veld aanwezig blijft. De temperatuur in dit toroidale plasma kan tot 10.000 K oplopen. Het plasma en de toorts worden schematise!! in het figuur 6 weergegeven. \Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Paging 13 \

Concentrische Kwarts Buizen Figtwr 6: Schema van een inductiefgekoppeld plasma Vloeistof monsters worden in het plasma gebracht als een in argon gas gesuspendeerd aerosol. Dit aerosol monster wordt door de binnenste van de drie kwarts buizen, die gezamenlijk de toorts vormen, geleid. De aerosol monsterstroom wordt door het centrum van het totridale plasma gevoerd waar het wordt gedesolveerd, geatomiseerd en de daaruit resulterende atomen en ionen worden geexciteerd. Na ecxitatie zenden de atomen van het monster licht uit op voor hen karakteristieke golflengten. Dit licht wordt door het optische systeem naar de detector geleid. Atomscan Advantage Emissie Bron De emissie bron van de Atomscan Advantage spectrometer is een Inductief Gekoppeld Argon Plasma (Inductively Coupled Argon Plasma - ICAP). De ICAP bron krijgt zijn vermogen van een 2 kw kristal gecontroleerde radio frequentie (RF) generator die bij of 27.12 MHz functioneert. Het uitgaande vermogen van de RF generator is gekoppeld aan een water gekoelde koperen spoel die de buitenste kwarts buis van de toorts omringt. Argon gas stroomt door de toorts zoals aangegeven in het figuur 7. De grootste stroom argon (het 'koelgas') met typisch 15 L/min, gaat tussen de buitenste en daar binnen liggende buizen. Kleinere gasstromen gaan tussen de middelste buis en de binnenste buis (auxiliary stroom), typische 0 to 2 L/min en door de binnenste buis (monster stroom) met typisch 0,6 tot 1 L/min. Pagina 14 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Monster stroom Hulp koelgas stroom Hoofd Koelgas Stroom (Plasma Gas) Figuur 7: ICAP Toorts Het volgende figuur toont de inductie spoel gewikkeld rond de toorts. De pie'zo-electrische ontsteker welke de vonk opwekt om het argon te ontsteken is ingebouwd in de hulp gas afvoer slang. Dit is de zwarte slang welke van doorvoer connector naar de onderste aansluiting in de toorts kamer gaat. De metalen onderdelen van deze aansluitingen zijn geisoleerd. De fiber licht pijp welke het plasma bewaakt om de hoog spanning uit te schakelen en een fout signaal te generen wanneer het plasma uitgaat; en de argon gas leidingen welke zijn aangesloten aah de verstuiver, plasma gas stroom en de hulp koel gas stroom. Deze gas leidingen zijn aangesloten aan de toorts en de bodemplaat van het toorts compartiment met snelkoppelingen. Het figuur toont niet het donkere glas venster welke de toorts compartiment afsluit en de bediener beschermt van het UV licht en RF straling. Vier duimschroeven houden dit venster op zijn plaats en twee schroeven zijn beveiligd met een veiligheidsschakelaars. Als het venster is verwijderd, wordt de hoog-spanning van de RF generator uitgeschakeld en het plasma gaat uit. Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pagina 15

Beveiligd deksel schroef gaten. Voorplaat moet op zijn plaats zijn om het plasma te kunncn ontsteken Figuur 8: Radiaal Plasma Compartiment *** WAARSCHUWING *** Direct in het plasma licht kijken veroorzaakt permanente oog beschadiging. Onder geen enkele omstandigheid mag gepoogt worden om in het plasma te kijken anders dan door het speciaal behandelde glas venster op de beschermde dcur. Probcer nooit de veilighcidsschakelaars te overbruggen. Het volgende figuur toont de radiale toorts kamer met de voorplaat verwijderd. De fiber welke in het plasma kijkt is te zien in het midden van de plaat welke de spoel op de achterkant van de 'matchbox' bevestigd. Paging 16 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

Figunr 9: Radiaal Plasma Toorts Kamer, Open Het volgende figuur toont de monster kamer van de Atomscan Advantage Axiale ICAP Spectrometer. Behalve voor de axiaal gepositioneerde toorts, is deze identiek aan het radiale instrument. Kwik Lamp Figure 10: Axiale Plasma Toorts Kamer De kwik lamp wordt gebruikt om het instrument te profieleren. Het beweegt desgewenst automatisch naar zijn juiste plaats, zodat het licht van de lamp door de entree spleet valt. Deze lamp is alleen aan als deze moet wordt gebruikt, zodat het onwaarschijnlijk is om deze te vervangen tijdens normaal gebruik. De kwik lamp kan niet door de gebruiker vervangen worden. Het licht van de kwik lamp is normaal niet te zien door de omhuising. Als er problemen zijn of het blauwe kwik licht is zichtbaar, contacteer dan uw TJA service vertegenwoordiging. Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pag'ma 17

*** WAARSCHUWING *** Direct in de kwik lamp kijken veroorzaakt permanente oog beschadiging. Probeer onder geen enkele omstandigheid de kwik lamp behuizing te openen. Als service noodzakelijk is, contacteer een geauthoriseerde TJA service vertegemvoordiging. Electnsche Aansluitingen *** GEVAAR *** Schakel uw ATOMSCAN ADVANTAGE nict in. Wacht op uw TJA service engineer om alle electrische voedingen te controleren. Om letsel of dood te voorkomen door per ongeluk de hoog spanningen aan te raken, verwijder geen van de panelen van uw ATOMSCAN ADVANTAGE spectrometer. De voedings eenheid, aan de onderkant van het cabinet, is uitgerust met een 2.5 meter netsnoer, zodat het stopcontact welke aanwezig moet zijn, zich ook binnen 2.5 meter van de achterkant van de voedings eenheid bevind. Dit wordt getoont in het volgende figuur Netsnoer Figuur 11: Netsnoerpositie Pa gin a 18 Atom scan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

De spanning voor de Atomscan Advantage ICAP spectrometer kunnen 200, 208, 220 en 240V bij 50/60 Hz en enkel fase zijn. Een speciale leiding van 30 amp is noodzakelijk direct van de meterkast. Deze leiding moet de vereiste spanning vasthouden onder voile belasting en tijdens het inschakelen. Bevredigende analytische resultaten worden nog gehaald bij een ±10% lijn spannings fluctuatie wanneer waterige oplossingen worden geanalyseerd, en bij een +10% en -5% spannings fluctuatie wanneer organische oplossingen worden geanalyseerd. *** GEVAAR *** De IRIS ADVANTAGE wordt bcschouwd als een hoge lekstroom instrument (4.3 milliampere). Zorg dat de niet stroom dragende veiligheids aarding aan alle electnsche veiligheids normen voldoet, dus minimum aardings weerstand. Het hoofd spectrometer netsnoer wordt getoond in figuur 11. Deze moet vast op het net worden aangesloten of door middel van een goed gekeurde netstekker. Buiten de VS word geen netstekker meegeleverd voor de kabel. Bruin (Fase) Blauw (Neutraal) Grocn/Geel NON-CURRENT CARRYING GROUND Figuur 12: Netsnoer kleur code Aarding is noodzakelijk in alle spectrometer systemen. De veiligheids aarde (groen met gele strepen) aangesloten op de voedings eenheid is een acceptabele aarding wanneer het voldoet aan de nationale electrische normen: 1. De aard (geel/groen) draad moet een niet stroom dragende instrument aarde zijn. 2. De aard draad is aangesloten aan een aardstrip of een speciaal aardpunt. 3. De aarding mag in geen geval aangesloten worden op inferieure plaatsen als CV leidingen, water leidingen of metalen constructie balken. Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Pag'ma 19

4. De aarding mag in geen geval op de nul leiding van het electrisiteits net aangesloten worden, behalve als dit op de secundaire zijde van een net-scheidings trafo wordt gedaan. De computer en printer welke meegeleverd wordt met het instrument zijn ingesteld om te werken op de lokale spanning en ontvangen hun spanning uit het stopcontact. Geen printer wordt meegeleverd met 220,230 of 240 V systemen. Hoofdschakel De hoofdschakelaar bevind zich aan de rechterkant van het, gezien vanaf de voorkant. Het volgende figuur toont de rechter zijpaneel van de Atomscan Advantage. Figuur 13: Atomscan Advantage zijpaneel welke de netspannings hoofdschakelaar toont De rode hoofdschakelaar nabij de achter kant van het paneel is voor de hoofd spannings voorziening. Het is AAN in de BOVEN positie (I) en UIT in de BENEDEN positie (0). Aan de linker kant van de hoofdschakelaar is een kliene schakelaar. Deze beschermd de 115 V voeding voor de hoofd transformator van de laagspanningsvoedingen. Pagina 20 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding

RF Generator *** WAARSCHUWING *** DE RF GENERATOR MAG NOOIT GEOPEND WORDEN DOOR NIET GEKWALIFICEERD PERSONEEL. DE GENERATOR BEVAT POTENTIEEL GEVAARLIJKE SPANNINGEN WELKE ERNSTIGE VERWONDINGEN OF ZELFS DE DOOD KUNNEN VEROORZAKEN. De RF generator is gelocaliseerd in het centrum van het onderste gedeelte van de Atomscan Advantage behuizing. De generator is intern gereguleerd om ± 10% van de nominale netspanning variatie te kunnen afvangen. Deze module genereerd RF energie welke het plasma in stand houdt. Het volgende figuur toont de achterkant van de Atomscan Advantage, met de RF generator zichtbaar in het midden van de onderkant van het instrument. RF Generator Hoofd schakelaar Figuur 14: Atomscan Advantage achterkant welke de RF Generator toont De RF generator is uitgerust met zijn eigen hoofdschakelaar, welke nooit gebruikt wordt tijdens normale bediening. Mocht deze schakelaar zich ooit uitschakelen, bel dan zo snel mogelijk uw geauthoriseerde TJA service vertegenwoordiging. Nooit zelf de schakelaar terug in schakelen. Uitschakelen van deze schakelaar duidt op een serieus probleem binnenin de generator. RF Generator Lucht Filter Onder normale omstandigheden moet het lucht filter van de RF generator elke 6 maanden worden schoongemaakt. In stoffige omgevingen vra.agt dit iets meet attentie. Doe dan het volgende. Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding Paging 21

Schakel het instrument uit. Schakel de hoofdschakelaar aan de rechter zijde van het instrument uit. Open de plasma compartiment deur en localiseer de schroef welke het deksel van het monochromator compartiment afsluit. Dit wordt getoond in het volgende figuur. Figuur 15: Locatie van de monochromator deksel bevestigings schroef. Verwijder de schroef en til het monochromator deksel op. Gebruik de stang om het deksel in de hoge toestand te houden zoals getoond wordt in het volgende figuur. Wees er zeker van dat de stang in het gat steekt zodat het deksel stabiel blijft staan. Figuur 16: Het monochromator deksel in opgeheven positie. Localiseer het filter. Deze is gemonteerd in de metalen houder welke kan worden geindentificeerd door de twee gaten. Steek een duim en vinger in deze gaten en trek het filter omhoog zoals getoond wordt in het volgende figuur. Paging 22 Atomscan Advantage Plasma Emissie Spectrometer Veiligheids Handleiding