Magnetic inductive flow sensors
|
|
- Käte Buchholz
- vor 5 Jahren
- Abrufe
Transkript
1 Magnetic inductive flow sensors Series induq VMI Advantages Robust metal housing Nominal pipe size ¼, ⅜ and ¾ Wide measuring range 1:6 (1:5) Frequency or analog and frequency output Delivery inlcuding works calibration certificate Type VMI2 / VMI1 Free pipe cross-section 1
2 Type VMI7 VMI1 VMI2 Characteristics Nominal pipe size ¼ ⅜ ¾ Process connection ½ NPT male ½ NPT male or ¾ NPT male 1 NPT male Inner diameter.4 x.16 inch.4 inch.79 inch Flow range GPM GPM GPM Accuracy* ±1.5 % of reading ±.3 % of range Repeatability* 1 % Response time <5 ms Signal output starting from.11 GPM.24 GPM 1.1 GPM Medium / min. conductivity of medium Water and other conductive liquids / 5 µs/cm Medium temperature F Ambient temperature Pressure rating Flow indication Degree of protection EN 6529 Min. 41 F, max. see figure temperature limits Max. 232 psi LED green, flow proportional flashing IP65 (with attached cable socket) Electrical data Electrical connection Plug connector M12 x 1 Power supply 24 VDC (±1 %) Current consumption 15 ma * Test conditions: Water 73 F at 15 ±1 µs/cm; standard pulse rate Temperature limits upper limit Frequency output Ambient [ F] Frequency and analog output 4 lower limit Medium [ F] 2
3 Three different versions available: Frequency output Analog output ma and frequency output Analog output...1 V and frequency output Frequency output VMI7 VMI1 VMI2 Pulse rate Optional* 2 pulses/gallon pulses/gallon 1 pulses/gallon pulses/gallon 25 pulses/gallon pulses/gallon Resolution Optional*.5 gallons/pulse gallons/pulse.1 gallons/pulse gallons/pulse.4 gallons/pulse gallons/pulse Signal shape Signal current Square wave signal, pulse duty ratio 5:5, Push-Pull 1 ma, current limited Analog output ma VMI7 VMI1 VMI2 Corresponds to flow rate**..5 GPM or...8 GPM..1 GPM or or...66 GPM Max. burden 25 Ω against GND Analog output...1 V VMI7 VMI1 VMI2 Corresponds to flow rate**..5 GPM or...8 GPM..1 GPM or or...66 GPM * Factory configurable ** Other ranges available on request 3
4 Typical pressure drop VMI7 / VMI1 Typical pressure drop VMI Pressure drop p [psi] VMI VMI Flow rate [GPM] Pressure drop p [psi] VMI Flow rate [GPM] VMI7 / VMI1 VMI2 Weitergabe sowie Vervielfältigung dieser Dokumente, Verwertung und Mitteilung ihres Inhalts sind verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. SIKA Unternehmensgruppe, Kaufungen, Deutschland M12x * n.4 Weitergabe sowie Vervielfältigung dieser Dokumente, Verwertung und Mitteilung ihres Inhalts sind verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. SIKA Unternehmensgruppe, Kaufungen, Deutschland M12x n Any unauthorized copying, disclosure or distribution of this document and its contents is strictly forbidden unless specifically authorised. Any violation will lead to indemnity. All rights reserved, particularly in the event of patent grant, registration of a utility model or design patent. SIKA Company Group, Kaufungen, Germany 1/2-14 NPT 3/4-14 NPT **.55 Plug connector LED 1.2 optional * =VMI7 ** =VMI1 optional All dimensions in inch * VMI7 ** VMI1 optional (Verwendungsbereich) (Zul. Abw.) (Oberfläche) Maßstab: 1:1 (Werkstoff, Halbzeug) Katalogabbildungen USA ISO 2768-m DIN ISO 132 (SIKA-Artikelnummer) Datum Name Bearb Thomas Gepr. Norm c ¾-14NPT optiona CT b neues Gehäuse CT a Dezimalpunkte CT Zust Änderung Datum Name (Urspr.:) Dr. Siebert & Kühn GmbH & Co KG Struthweg Kaufungen Any unauthorized copying, disclosure or distribution of this document and its contents is strictly forbidden unless specifically authorised. Any violation will lead to indemnity. All rights reserved, particularly in the event of patent grant, registration of a utility model or design patent. SIKA Company Group, Kaufungen, Germany (Ers. f.:) NPT.98 (Gewicht) VMI7.../VMI1.../VMI2... Abmessungen VMI 7/1/2 NPT Plug connector für Datenblatt USA Blatt MID-29a 1 2 Bl. (Ers. d.:) LED optional 1.14 All dimensions in inch (Verwendungsbereich) (Zul. Abw.) (Oberfläche) Maßstab: 1:1 (Werkstoff, Halbzeug) Katalogabbildungen USA ISO 2768-m DIN ISO 132 (SIKA-Artikelnummer) Datum Name Bearb Thomas Gepr. Norm c ¾-14NPT optiona CT b neues Gehäuse CT a Dezimalpunkte CT Zust Änderung Datum Name (Urspr.:) Dr. Siebert & Kühn GmbH & Co KG Struthweg Kaufungen (Ers. f.:) VMI Abmessungen für Date MID- Materials Electrodes Stainless steel Process connections Stainless steel Measuring pipe PEEK-GF3 O-rings EPDM / FKM optional Housing Casted aluminum 4
5 Order code Example VMI SS Type VMI VMI Flow range / Process connection GPM / ½ NPT male thread...5 GPM...8 GPM...5 GPM...8 GPM GPM / ½ NPT male thread GPM / ¾ NPT male thread GPM / 1 NPT male thread...66 GPM...66 GPM Mounting straps Without (standard) With mounting straps SS LS Material O-rings EPDM (Standard) FKM (Option) 1 5
6 Accessories Length Order code Connection cable with 4-pin cable socket M12 x 1, angle type moulded lead, sheathing material PUR, shielded, (T max = 176 F) UL-approval 1 ft 16 ft 33 ft XVT253 XVT29 XVT27 6
Magnetic inductive flow sensors
Magnetic inductive flow sensors Series induq VMI Advantages Robust metal housing Nominal diameter DN 7, DN 1 and DN 2 Wide measuring range 1:6 (1:5) Frequency or analogue and frequency output Delivery
MehrVortex flow sensors. Series VVX. Type VVX20. Type VVX15
Vortex flow sensors Series VVX Type VVX5 Type VVX0 Technical data VVX5 VVX0 VVX5 Nominal pipe size ½ ¾ Process connection ½ NPT ¾ NPT or QuickFasten NPT Inner diameter 0.5 inch 0.75 inch inch Flow range
MehrDurchflussmessung Magnetisch Induktive Durchflusssensoren BEST VMI20 SELLER
1 Durchflussmessung Magnetisch Induktive Durchflusssensoren VMI induq VMI7 BEST SELLER VMI2 Ihre Vorteile Baureihe VMI Robustes Metallgehäuse für hohe Temperaturen und Drücke Weiter Messbereich 1:6 (1:5)
MehrMAGNETIC INDUCTIVE FLOW SENSORS
JJ Series induq VMM JJ Series induq VMI JJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS DB_Magnetic_Inductive_Flow_Sensors 01/2017 63 Magnetic inductive flow sensors Principle of operation The smart
MehrTurbine flow sensors. For potable water applications, series VTY10. Type VTY10, brass. Type VTY10, plastic
Series VTY Turbine flow sensors of the series VTY were specially developed for the use in potable water mass production applications. Flexible, customer- and application-oriented customisations to existing
MehrThread connections QuickFasten. vortex Flow sensors
JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors_USA 07/07 53 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated
MehrPush-in flow sensors. Tap water detection Water treatment Leak detection
Push-in flow sensors Push-in flow sensors of the type VTY, VTH// were specially developed for the installation in fittings and feature an easy and space-saving system integration. Typical applications
Mehrvortex Flow sensors Contains products with:
JJ VVX 15 JJ VVX 25 vortex Flow sensors Contains products with: DS_Vortex_Flow_Sensors 01/2015 55 Vortices for precise flow measurement Function Alternate vortices rotating in opposite directions are generated
MehrAnschlusskopf Typ B / Typ J Winkelsteckverbinder Dieselmotoren-Zeigerthermometer. KombiTemp. Temperaturfühler mit örtlicher Anzeige
JJ Anschlusskopf Typ B / Typ J JJ Winkelsteckverbinder JJ Dieselmotoren-Zeigerthermometer KombiTemp Temperaturfühler mit örtlicher Anzeige DB_KombiTemp / 5 Doppelte Temperaturüberwachung mit nur einer
MehrMagnetic inductive flow sensors
Magnetic inductive flow sensors Series induq VMM Advantages Rapid signal processing with a 6-bit microcontroller Password protection Self-test anguage selection: German, English ow-flow suppression Empty
MehrThread connections QuickFasten. vortex Flow sensors
JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors /207 59 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated behind
MehrThread connections QuickFasten. vortex Flow sensors
JJ Thread connections JJ QuickFasten vortex Flow sensors DS_Vortex_Flow_Sensors 06/06 57 Vortex flow sensors Principle of operation Alternate vortices rotating in opposite directions are generated behind
MehrSeries Turbotron. Series VTY Push-in flow sensors. Turbine flow sensors
JJ Series Turbotron JJ Series VTR JJ Series VTY JJ Push-in flow sensors Turbine flow sensors DS_Turbine_flow_sensors_USA 3/8 87 Turbine flow sensors Sensor housing Cable Hall effect sensor Pipe section
MehrVVX. VVX20 QuickFasten. Technisches Datenblatt BEST BEST. Durchflussmessung Vortex-Durchflusssensoren. Ihre Vorteile
Durchflussmessung Vortex-Durchflusssensoren VVX VVX20 BEST SELLER VVX20 QuickFasten BEST SELLER Ihre Vorteile Baureihe VVX Kein mechanischer Verschleiß Durchflusssensor ohne bewegte Teile für Wasser Höchste
MehrFor male thread For union nut, type Da / type Dc For plain immersion tubes. Protection tubes
JJ For male thread JJ For union nut, type Da / type Dc JJ For plain immersion tubes Protection tubes DS_Protection_tubes 06/201 129 Reliable and certain We manufacture protection tubes for our industrial
MehrWith pipe tees (inline) Direct installation (insertion) With interchangeable paddles For air flow. flow switches
JJ With pipe tees (inline) JJ Direct installation (insertion) JJ For HVAC applications JJ With interchangeable paddles JJ For air flow flow switches DS_Flow_switches 06/2017 7 Flow switches SIKA has over
MehrSeries VHS / VH6 Series VKS / VK6
JJ Series VHS / VH6 JJ Series VKS / VK6 Level switches DS_Level switches 06/2016 225 Level switches Principle of operation Level switches are the easy and reliable solution for monitoring fluid levels.
MehrSeries VHS / VH6 Series VKS / VK6
JJ Series VHS / VH6 JJ Series VKS / VK6 Level switches DS_Level switches 06/2017 233 Level switches Principle of operation Level switches are the easy and reliable solution for monitoring fluid levels.
Mehrvortex durchflusssensoren
JJ Gewindeanschluss JJ QuickFasten vortex durchflusssensoren DB_Vortex_Durchflusssensoren 06/06 57 Vortex Durchflusssensoren Funktionsprinzip Hinter einem umströmten Störkörper entstehen gegenläufige und
MehrDatenblatt. Remote-I/O - u-remote UR20-4AO-UI or 4-wire connection; 16-bit resolution; 4 outputs
2- or 4-wire connection; 16-bit resolution; 4 outputs The analogue output module controls up to 4 analogue actuators with +/-10 V, +/-5 V, 0...10 V, 0...5 V, 2...10 V, 1...5 V, 0...20 ma or 4...20 ma with
MehrMikro-Magnetventile Typ 65 NW 0,5/1/1,6/2 2/2- und 3/2-Wege Sitzventile Direktgesteuert
NW 0,//,6/ /- und /-Wege Sitzventile 0.//.6/ mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar, z.b. drei unterschiedliche Sockelformen (Standard-,
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
MehrAccessories // Adapter sleeves // Measuring inserts
1 Temperature Calibration Temperature Calibrators TP Accessories & Options Accessories // Adapter sleeves // Measuring inserts Standard sleeve Infrared sleeve Tub insert Surface sleeve Ø 8 mm brass Accessories
MehrFlüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors. Serie/Series L-BV2. Ersatzteilliste Spare part list
Flüssigkeitsring -Vakuumpumpen/ - Kompressoren Liquid ring vacuum pumps/ compressors Ersatzteilliste Spare part list Serie/Series L-BV2 Typ / Type 2BV2060 2BV2061 2BV2070 2BV2071 Gardner Denver Deutschland
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrInkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm Impulse pro Umdrehung
Inkrementale Drehgeber Durchgehende Hohlwelle ø30 bis ø45 mm 600...1200 Impulse pro Umdrehung Merkmale Durchgehende Hohlwelle ø30...45 mm Optisches Abtastprinzip Robustes Leichtmetall-Gehäuse Ausgangsstufe
Mehrdiameter DN 15 DN max. 25bar (see table) grey cast iron GG25, cast steel GS-C25N, stainless steel AISI 303
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Kolbenventil Nennweite
Mehrdiameter DN 2,0 6,0 0 max. 48bar (see table) body material brass, AISI 303, AISI 316
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrSchaltfunktion function. piping. Technische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012
fremdgesteuert externally controlled Schaltfunktion function Elektrischer Anschluss M12x1 electrical connector M12x1 Die Ventile arbeiten als Druckwaage und werden im Bypass eingesetzt. Der Mediumsdruck
MehrLORENZ MESSTECHNIK GmbH
DR-2112, DR-2112-R DR-2412, DR-2412-R Drehmomentsensor, rotierend Torque Sensor, rotating Drehmomentsensor, rotierend Torque Sensor, rotating Nenndrehmoment von 0,1 N m... 20000 N m - Nominal torque from
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 1,7 Druckbereich Gehäusewerkstoff Dichtwerkstoff Sitzventil mit Handnotbetätigung
Mehr2/2-way plastic solenoid valve - Type 110
- direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 6,0 Druckbereich Sitzventil
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 148 Type 148
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 2,0 8,0 Druckbereich Gehäusewerkstoff
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 111 Type 111. direktgesteuert mit Trennmembrane flüssigkeitsgedämpft
direktgesteuert mit Trennmembrane flüssigkeitsgedämpft direct acting with isolating diaphragm fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
zwangsgesteuert force pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN
Mehr2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 270 / 271 / 272 Type 270 / 271 / 272. direktgesteuert direct acting. Nennweite DN 10 50
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich
MehrSpecification. DESIGN Pressure actuated needle valve with electropneumatic. OPERATION Continuous control
Technische Daten BAUFORM Druckgesteuertes Nadelventil mit aufgebautem Stellungsregler PG01. Specification DESIGN Pressure actuated needle valve with electropneumatic positioner. Artikel: AND STEUERFUNKTIONEN
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
Mehr2/2-way solenoid valve - Type 218
- direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 10/2015
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff Dichtwerkstoff
Mehrdirektgesteuert direct acting
1 direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Sitzventil Nennweite
MehrMade in W-Germany. kv=0,12 l/min (NW 0,5) P2[bar] kv=0,45 l/min (DN 1) P2[bar] kv=0,70 l/min (NW 1,5) P2[bar]
NW 0,//, /- und /-Wege Sitzventile 0.//. mm Orifice /- and /-Way Poppet Valves Als Standard sind die Ventile in vielfältigen Ausführungen lieferbar z. B.: drei unterschiedliche Sockelformen (Standard-,
MehrDatenblatt. P-series PDU 2.5/4/4AN
Turn five into three that's the winning formula of the new P series with the PUSH IN connection system in which the pitches for 2.5, 4, 6 and 10 mm² are each combined in one terminal block. That means
MehrOvercurrent Protection Leaded Disks, Coated, 12 V, 24 V
B99* C 93 C 99 Applications Overcurrent and short-circuit protection b 3, max. Features Lead-free terminals Manufacturer s logo and type designation stamped on in white Low resistance For rated currents
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Schnellentlüftungsventil Nennweite DN 2,0 2,5 Schnellentlüftung DN 6,0 Druckbereich Gehäusewerkstoff
MehrDIN EN form A 230V 50Hz, 24V DC, special voltages voltage tolerance + / - 10% acc. VDE 0580 power consumption 230V 50Hz: 6,5VA 24V DC: 5W
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 15 50
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
MehrTECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor
TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,
MehrTechnisches Datenblatt Technical Data Sheet. Drehzahlsensoren / Speed Sensors 1 Kanal Hall M14 LD Familie 1 Channel Hall M14 LD Type
Drehzahlsensoren / Speed Sensors 1 Kanal Hall M14 LD Familie 1 Channel Hall M14 LD Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -25 +85 C Data summary Power
Mehr2/2-Wege Kunststoff-Magnetventil 2/2-way plastic solenoid valve. Baureihe 135 Type 135
zwangsgesteuert, flüssigkeitsgedämpft force pilot operated, fluid-damped Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 15 50 Druckbereich Gehäusewerkstoff
Mehr0,5 max. 16bar (see table) body material brass, AISI 303, AISI 316
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Bauart Nennweite DN 13 50
MehrFür Außengewinde Für Überwurfmutter, Typ Da / Typ Dc Für glatte Tauchrohre
JJ Für Außengewinde JJ Für Überwurfmutter, Typ Da / Typ Dc JJ Für gatte Tauchrohre THERMOMETERschutzrohre DB_Thermometerschutzrohre 06/201 129 Zuverässig und sicher As Zubehör zu unseren Maschinenthermometern,
MehrGasring-Vakuumpumpen/- Kompressoren. Serie/Series G-BH1. Ersatzteilliste Spare part list. Typ / Type 2BH1 1
Gasring-Vakuumpumpen/- Kompressoren Ersatzteilliste Spare part list Serie/Series G-BH1 Typ / Type 2BH1 1 Gardner Denver Deutschland GmbH Postfach 1510 97605 Bad Neustadt / Saale Germany Tel.: +49 7622
Mehr2/2-way plastic solenoid valve - Type 104
- direktgesteuert mit Trennmembrane direct acting with isolating diaphragm Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 1,0 2,5 Druckbereich Gehäusewerkstoff
MehrIDG. Drehzahlsensor / Speed Sensor
Drehzahlen sicher erfassen, anzeigen und kontrollieren For reliable measurement, control and indication of rotational speeds Analogsignal 1-Kanal 1-channel analog signal IDG Drehzahlsensor / Speed Sensor
MehrBaureihe 269 Type /2-Wege Coaxialventil 2/2-way coaxial valve. direktgesteuert direct acting. diameter DN Nennweite DN 10 32
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich
MehrA P max. 16bar P R max. 64bar R P max. 16bar
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 50 Druckbereich
Mehrdirektgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow
1 direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: NC (stromlos geschlossen) function A: NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
Mehr2/2-Wege Coaxialventil 2/2-way coaxial valve. Baureihe 269 Type 269. direktgesteuert direct acting
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 32 Druckbereich
Mehrservogesteuert pilot operated
1 servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: NO (stromlos offen) function B: NO (normally open) Bauart Sitzventil mit Membrandichtung
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 11/2011
direktgesteuert mit PTFE-Faltenbalg direct acting with PTFE-bellow Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally
MehrInkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb Impulse pro Umdrehung
Inkrementale Drehgeber Ex-Schutzzulassung ATEX II 2 G Ex db e IIC T5/T6 Gb und IECEx Ex db e IIC T5/T6 Gb 25...5000 Impulse pro Umdrehung EEx OG 9 - inkremental Merkmale Drehgeber Inkremental / ATEX /
MehrCOUPLING TECHNOLOGY. Water Pneumatic Hydraulic Electrical TYPE COUPLING TECHNOLOGY
Water Pneumatic Hydraulic Electrical Accessories 2 Temperature Range - Temperaturbereich - C +180 C (+ F +356 F) Nitrile (V) - C +0 C (-4 F +2 F) Nitrile (N) - C +0 C (-4 F +2 F) EPDM (E) 0 C +270 C (+23
MehrInductive proximity switch
3RG4070-0CD00-PF NO and NC / Schließer und Öffner 3RG4070-3CD00-PF NO and NC / Schließer und Offner 3RG4070-7CD0-PF NO and NC Schließer und Öffner 3RG4070-7CD0-PF NO and NC Schließer und Öffner Cable /
Mehr[82252] Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U...
DIGICONTROL- Gerätedatenblatt F-SPT-U www.gfr.de [82252] Kategorie: Sensoren und Wächter Druckmessumformer für gasförmige oder flüssige Medien DIGICONTROL F-SPT-U... Anwendung Der Druckmessumformer F-SPT-U...
MehrDILO soldering unions
DILO soldering unions are particularly used in factory fabrication area piping. DILO offers a very wide variety of unions. Soldering unions are available either with soldering connections on both ends
MehrMagnetventile. Solenoid Valves. Betätigungsmagnet Typ 64 für Baureihe 64/79/81/83/87. Type 64 for Series 64/79/81/83/87
Magnetventile Solenoid Valves Betätigungsmagnet Typ 64 für Baureihe 64/79///7 Type 64 for Series 64/79///7 Elektrische Daten 64er Magnetsystem Elektrische Ausführung: gemäß VDE 050, VDE 00 Ansprechstrom:
MehrELMEKO GmbH + Co. KG Graf-Zeppelin-Str Liebenscheid Germany Tel. +49/2736/
LED-Schaltschrankleuchten LLE-400 und LLE-700 LED Enclosure Lighting LLE-400 and LLE-700 Hochvolt-LED-Technik, Anschluss an 230V AC 2 Varianten: mit Bewegungsmelder oder Türendschalter mit 230V Steckdose
MehrCANNON STANDARD Seite 1 von 5. CAI Industrial Circular Connector
1.1 Ordering Information CANNON STANDARD Seite 1 von 5 C A I 0 2-1 8 T 0 0-0 2 0 0 - P - B 1-0 0 11.) Modification Code 00 = Standard 01 = FKM-Sealing 10.) Plating 1 = A34 Nickel 2 = A240 Zinc-Nickel 9.)
MehrLORENZ MESSTECHNIK GmbH
LORNZ MSSTHNIK GmbH DR-2212, DR-2212-R DR-2512, DR-2512-R Drehmomentsensor, rotierend Torque Sensor, rotating Drehmomentsensor, rotierend Torque Sensor, rotating Nenndrehmoment von 0,1 N m... 20000 N m
MehrP A max. 100bar A P max. 16bar
1 Schaltfunktion A: function A: direktgesteuert Modulbauweise NC (stromlos geschlossen) Schaltfunktion B: NC (normally closed) function B: NO (stromlos offen) NO (normally open) direct acting modular design
MehrELMTEC. Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall Zoll Familie 1 Channel Hall Inch Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K Data summary
MehrESD - Kunststoff - Schwer - Palette Doc. Num. N x 800 x 160 mm Doc. Part 002 Doc. Ver. 02 INHALTSVERZEICHNIS
Date: 2017-05-30 Page 1 of 6 INHALTSVERZEICHNIS Änderungen... 2 Frühere Ausgaben... 2 1 GELTUNGSBEREICH... 2 2 MITGELTENDE DOKUMENTE... 2 3 ANWENDUNG... 2 4 SPEZIFIKATION... 3 4.1 Abmessungen... 4 4.2
MehrHochstromkontakte High Power Contacts
Hochstromkontakte High Power Contacts Technische Daten Technical Data Mechanische Daten Mechanical Data Steckkraft (Kontaktpaar) Mating force (pair of contacts) Ziehkraft Unmating force Temperaturbereich
MehrKunststoff - Leicht - Palette Doc. Num. N x 800 x 150 mm Doc. Part 001 Doc. Ver. 02 INHALTSVERZEICHNIS
Date: 2015-12-16 Page 1 of 7 INHALTSVERZEICHNIS Änderungen... 2 Frühere Ausgaben... 2 1 GELTUNGSBEREICH... 2 2 MITGELTENDE DOKUMENTE... 2 3 ANWENDUNG... 2 4 SPEZIFIKATION... 3 4.1 Abmessungen... 4 4.2
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 06/2012
direktgesteuert direct acting Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Schaltfunktion B: function B: NO (stromlos offen) NO (normally open) Nennweite DN 10 Druckbereich
MehrBaureihe 464 Type Wege Kugelhahn pneumatisch betätigt 3-way ball valve pneumatic actuator
Bauart Nennweite DN 8 DN 50 Anschluss Kugelhahn mit pneumatischem Schwenkantrieb G1/4 G2 Betriebsdruck Messing: DN15 DN20 = PN30 DN25 = PN16 DN32 DN50 = PN10 Edelstahl: PN63 Gehäusewerkstoff Armatur: Edelstahl
MehrSpecification. DESIGN Body consists of one part MR3400xx approval acc. to 1935/2004/EC. CONNECTION Female thread 1 /4" up to 4" acc.
Technische Daten BAUFORM -teilige Körperkonstruktion MRxx mit Zulassung nach 9//EG ANSCLUSS Innengewinde: /" bis " nach ISO EINBAULAGE Beliebig, vorzugsweise für waagerechten oder senkrechten Einbau. Durchfl
MehrProportional Magnetventil BFW PROPORTIONAL MAGNETVENTILE BFW. Proportional Solenoid Valve BFW. Technische Daten l Technical Data
Proportional Magnetventil BFW Erhältlich in CETOP und CETOP Durchflussmenge CETOP :, oder 7 l/min Durchflussmenge CETOP :, 7 oder l/min Inkl. Befestigungsschrauben und Ventilstecker Grundplatten zu den
MehrCAN-Nachrichten CAN messages CMGA. Anlage zur Beschreibung Installationshandbuch. Annex to description Installation manual NH
CAN-Nachrichten CAN messages CMGA de en Anlage zur Beschreibung Installationshandbuch Annex to description Installation manual 76178 101NH Symbole/Symbols: Warnung Warning Vorsicht Caution Hinweis Note
MehrKunststoff Leicht - Palette (CS 1) Doc. Num. N x 800 x 150 mm Doc. Part 001 Doc. Ver. 00 INHALTSVERZEICHNIS
Date: 2017-10-12 Page 1 of 6 INHALTSVERZEICHNIS Änderungen 2 Frühere Ausgaben... 2 1 GELTUNGSBEREICH... 2 2 MITGELTENDE DOKUMENTE... 2 3 ANWENDUNG... 2 4 SPEZIFIKATION... 3 4.1 Abmessungen... 4 4.2 Durchbiegung...
MehrTechnische Änderungen vorbehalten / modifications reserved Stand / stand: 07/2012
Baureihe 786-E Type 786-E fremdgesteuert externally controlled Schaltfunktion: function: NC (stromlos geschlossen) NC (normally closed) Elektrischer Anschluss M12x1 electrical connector M12x1 Bauart stufenlose
MehrCompressed air - dewpoint 10K under ambient temperature - ISO8573-1, Kl. 3 Durchflussrichtung Flow direction EIN: von 1-2 AUS: von 2 3
3/2 Wegeventil mit PIEZO-Pilotventil Baureihe P20 3/2 way valve with Piezo-pilot valve Series P20 P20 381RF-* NW 2 Eigenerwärmungsfrei Ein Produkt für alle Ex-Bereiche Kompatibel zu Microcontrollern Kompatibel
MehrInhaltsverzeichnis Index
Inhaltsverzeichnis Index Typ Type Seite Page FDL 7-1 FDR 7-2 FMR 7-3 7-0-1 Zahnradmengenteiler Rotary geared flow divider Zahnradmengenteiler Typ FDL Rotary geared flow divider type FDL Technische Daten
MehrBarcodescanner CLV62x, CLV63x, CLV64x, CLV65x
T E C H N I S C H E I N F O R M AT I O N Diese Technische Information ergänzt die Betriebsanleitungen der Barcodescanner-Familie CLV6xx mit Angaben zur UL60950-Zertifizierung. Betriebsanleitung CLV62x
MehrTechnisches Datenblatt Technical Data Sheet. Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Familie 1 Channel Hall M18 Type
Drehzahlsensoren Speed Sensors 1 Kanal Hall M18 Familie 1 Channel Hall M18 Type Kurzdaten Versorgung Frequenzbereich Betriebstemperatur Schutzart (IEC 529) 0 15.000 Hz -40 +125 C IP67, IP69K (siehe Typen)
Mehr2/2-way solenoid valve - Type 239
servogesteuert pilot operated Schaltfunktion A: function A: NC (stromlos geschlossen) NC (normally closed) Bauart Nennweite DN 10 40 Druckbereich Gehäusewerkstoff Messing Dichtw erkstoff Sitzventil mit
Mehr/ Technische Änderungen und drucktechnische Irrtümer vorbehalten.
EZ-0225-V10 Air Bearing Spindle High accurancy air bearing spindle with direct drive. Equipped with an water-cooled synchronous motor (frequency at nominal speed 400 Hz), Power output 1880 W. Rotary encoder
MehrTechnische Änderungen und Irrtum vorbehalten.
Technische Änderungen und Irrtum vorbehalten. Allgemeintoleranzen Allgemeintoleranzen DIN ISO 68 T1 - m DIN ISO 68 T2 - K DIN ISO 68 T1 - m DIN ISO 68 T2 - K 14 14 14 OTE: The information or material
MehrTRANSMETRA. DR Nm. Rotierender Drehmomentsensor (Schleifring) rotation torque sensor (slipring) G 0.1%
Nenndrehmoment von 1 N m... 500 N m Hohe essgenauigkeit ab 0,1% v. Endwert Integrierte Drehzahl-/Drehwinkelmessung Beide Wellenenden mit Passfedern Sehr kurze axiale Baulänge Hohe Drehsteifigkeit Zuverlässig
MehrTECHNISCHE DATEN Drucksensor TECHNICAL DATA Pressure Sensor
TECHNISCHE DATEN Drucksensor TECHNICAL DATA Seite Modell Bauart Einstellbereiche Elektrischer Anschluß Page Model Design Setting range Electrical link 2 Typ 900 Drucksensor 0-1 bar, 0-10 bar, 0-100 bar,
MehrBestellformel BI 8 F 24 V DC 15 % ED Order specifications Hubmagnet
Bestellformel % ED Order specifications Litze (Standardlänge 0 cm) Lötpins (Rastermaß) L lying leads (0 cm standard length) Soldering pins (grid dimensions) Nennspannung (Standardspannung) ) 4 Nominal
MehrKunststoff - Schwer - Palette (H1) Doc. Num. N x 800 x 160 mm Doc. Part 002 Doc. Ver. 03 INHALTSVERZEICHNIS
Date: 2017-05-30 Page 1 of 6 INHALTSVERZEICHNIS Änderungen... 2 Frühere Ausgaben... 2 1 GELTUNGSBEREICH... 2 2 MITGELTENDE DOKUMENTE... 2 3 ANWENDUNG... 2 4 SPEZIFIKATION... 3 4.1 Abmessungen... 4 4.2
MehrPhotometric Report 25 Lens Kit
Photometric Report 25 Lens Kit R-G-B US Distribution Elation Professional Los Angeles, Ca. 800-333-0644 web: www.elationlighting.com info: sale@elationlighting.com support: support@elationlighting.com
MehrHandbuch KT. User Manual KT
141215 1 KT Handbuch KT Standardtemperatursensoren Deutsch Seite 2 User Manual KT Standard Temperature Sensors English page 5 141215 2 KT DEUTSCH 1. Allgemeines Aamgard Motorsport Service vertreibt eine
MehrKühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00
Beschreibung und Bedienungsanleitung Technical Documentation and Operation Manual Kühlgehäuse für Pyrometerserie Metis Cooling jacket for pyrometer series Metis KG10-00 Inhalt S./P. 1. Beschreibung / Description...
MehrWestenberg Wind Tunnels
MiniAir20 Hand measurement device for flow, humidity and temperature The hand measurement device MiniAir20 is used for the acquisition of temperature, relative humidity, revolution and flow velocity such
Mehr