MAV 1351-1 MG 1 SPLIT 231884 MG 1 SPLIT



Ähnliche Dokumente
MONTAGEANLEITUNG EXTRA MISCHGRUPPE MG 2 SPLIT FÜR SPLIT Inneneinheit ohne integriertem Speicher

INSTALLATION INSTRUCTIONS ENERGY METER FOR SPLIT indoor unit without integrated tank

Serviceinformation Nr. 02/11

UWC 8801 / 8802 / 8803

Softwareupdate-Anleitung // AC Porty L Netzteileinschub

MONTERINGSANVISNING EXTRA SHUNT ESV 22 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 22 FOR NIBE SPLIT

Anwendungsbeispiele Verstärker Application Examples Amplifiers

F1220, F1230, F1120, F1130

IR RECEIVER Bedienungsanleitung User s Manual

CABLE TESTER. Manual DN-14003

miditech 4merge 4-fach MIDI Merger mit :

_00 Eastern Europe,11/2010. Wall-hung boilers eloblock Elektro-Wandheizgeräte eloblock VE 6 VE 9 VE 12 VE 14 VE 18 VE 21 VE 24 VE 28

MobiDM-App Handbuch für Windows Mobile

Elektroanleitung Danfoss Wärmepumpe DHP-A

Installation Instructions

Wenn Russland kein Gas mehr liefert

Anleitung für DT-TPC Tel Modul

Serviceinformation Nr. 05/10

Installateurhandbuch AXC 40. Zubehör IHB DE LEK

Kurzanleitung um Transponder mit einem scemtec TT Reader und der Software UniDemo zu lesen

Contact 1600 QUICK REFERENCE GUIDE GUIDE D UTILISATION BEDIENUNGSANLEITUNG GUÍA DE REFERENCIA RÁPIDA GUIDA RAPIDA. CHANGING THE WAY

Readme-USB DIGSI V 4.82

Das neue Volume-Flag S (Scannen erforderlich)

Austausch Saugschlauch am CUBE-Dieseltank

I-Energieversorgung I-Power Supply

Funktionsbeschreibung/ Montageanweisung Steuermodul DSM 400 für Dunstabzugshaube DA 6000 W

Re:connect. Extension Kit für Multimedia-Modul. Dominating Entertainment. Revox of Switzerland. D 01

Elinkoppling. Allmänt. Innehåll. Produkter med stående ellåda. Produkter med liggande ellåda. Denna serviceinstruktion beskriver byte av elpatronskort

Electrical testing of Bosch common rail Injectors

Electrical testing of Bosch common rail piezo injectors


4.) Geben Sie im Feld Adresse die IP Adresse des TDC Controllers ein. Die Standard Adresse lautet

Windows Server 2012 R2 Essentials & Hyper-V

Installation mit Lizenz-Server verbinden

RS232-Verbindung, RXU10 Herstellen einer RS232-Verbindung zwischen PC und Messgerät oder Modem und Messgerät

VPN / IPSec Verbindung mit dem DI 804 HV und dem SSH Sentinel

Live Streaming => Netzwerk ( Streaming Server )

SanStore: Kurzanleitung / SanStore: Quick reference guide

TECHNOLOGY MADE IN ITALY ÖLKÜHLER OIL COOLERS

Technical Support Information No. 123 Revision 2 June 2008

DVD MAKER USB2.0 Installation Anleitung

Electrical tests on Bosch unit injectors

Version/Datum: Dezember-2006

PROFIBUS-DP Repeater 1 to 1 and 1 to 5 with optional level converter module

FIRMWARE UPDATE TAPMOTION TD

Konfigurieren eines HHR Gerät, um es über eine CBX800 an Profibus anzubinden

Werbemittel-Spezifikationen

Ex-Barriere für Diagnoseeinheit SITRANS DA400 / Ex-barrier for diagnostics unit SITRANS DA400 7MJ2010-1AA 0032

2-Draht Netzwerkübertrager-Set mit POE

CarMedia. Bedienungsanleitung Instruction manual. AC-Services Albert-Schweitzer-Str Hockenheim

EMCO Installationsanleitung Installation instructions

Wireless LAN Installation Windows XP

INSTALLATION AND OPERATING INSTRUCTIONS FOR LPS203-M LPS203-M 操 作 指 示

LX 16 Akustisches Variometersystem Handbuch

USB-Stick (USB-Stick größer 4G. Es ist eine größere Partition notwendig als die eines 4GB Rohlings, der mit NTFS formatiert wurde)

Quanton Manual (de) Datum: URL: )

Installation und Start der Software AQ2sp Installation and Start of the software AQ2sp

Hama GmbH & Co KG Postfach Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/

EchoLink und Windows XP SP2

KIP Druckerstatus Benutzerhandbuch KIP Druckerstatus Installations- und Benutzerhandbuch

Produktinformation _182PNdeen

Honeywell AG Hardhofweg. D Mosbach MU1H-1220GE23 R1001

Flow Indicator - Messgerät für Druck und Durchfluss

Updatehinweise für die Version forma 5.5.5

Externer Temperaturfühler External temperature sensor

LS3/5A customer questionnaire

Quadt Kunststoffapparatebau GmbH

Klausur BWL V Investition und Finanzierung (70172)

Registrierungsprozess des Boardgeräts (OBU) Inhalt Registrierung auf der Online-Benutzeroberfläche HU-GO

Installation Hardlockserver-Dongle

Regelgerät für thermische Solaranlagen. vecto Hydraulikschemen

A-CERT CERTIFICATION SERVICE

Airjack LL-22 / LL-32

Homepage with actual measurement data from buildings. Homepage mit realen Monitoringdaten von Gebäuden

4-Sensor Parking System

Dichtkegel-Verschraubungen mit 24 -Kegel und O-Ring Viton. Cone Sealing Couplings with 24 -Cone and O-ring Viton

Lab - Installieren der Software von Drittanbietern unter Windows Vista

Newest Generation of the BS2 Corrosion/Warning and Measurement System

Zubehör für mehrpolige Steckverbinder

Es können nur Werte ausgelesen werden, Es kann -NICHT- geschaltet werden!!

Wie verbinde ich ein JBOD-System mit dem QStore QMX? - 1

Installation manual / Montageanleitung WBC2 splice patch with Fibertray Spleissung/Rangierung mit Fibertray

Anwenderdokumentation PersoSim

Output Choke Installation Instructions

MAKING MODERN LIVING POSSIBLE. Danfoss Link SCM Simple Communication Module Installationsanleitung. Danfoss Heating Solutions

EMV und Medizinprodukte

Lockable Tablet Mount

Mitarbeiter IVR - Wozu

Wandarm inkl. Montagebox und Netzteil Wall bracket incl. installation box and power supply

Pressemitteilung. Die intelligente Lösung für die Heizungsmodernisierung: Wärme aus Luft und Gas mit hoher Kostenersparnis.

TECHNICAL DATA SHEET Member of Uponor Group

Schnell-Start-Anleitung Quick Start Guide

Montageanleitung Konverter RS422 - USB

Systemkomponenten. Regelung BW/H

ZZ Systembeschreibung

mobilcom-debitel SmartHome Schnell-Start-Anleitung Quick Start Guide

Bedienungsanleitung Opera ng Manual

Hydraulischer Abgleich des SAM 40 im Heizsystem

KURZANLEITUNG. Firmware-Upgrade: Wie geht das eigentlich?

Transkript:

MAV 1351-1 231884 GB DE INSTALLATION INSTRUCTIONS EXTRA SHUNT FOR SPLIT indoor unit with integrated tank/split indoor unit without integrated tank MONTAGEANLEITUNG EXTRA MISCHGRUPPE FÜR SPLIT Inneneinheit mit integriertem Speicher/ SPLIT Inneneinheit ohne integriertem Speicher LEK LEK

INSTALLATION INSTRUCTIONS GB General This accessory is used when SPLIT indoor unit with integrated tank/split indoor unit without integrated tank is installed in houses with two di erent heating systems that require di erent supply temperatures, for example, in cases where the house has both a radiator system and an under r heating system. In the following text heating system 1 covers the system that requires the greater temperature and that is connected to the normal supply line respectively return line connection. Heating system 2 covers the heating system that works at the lower temperature. The water w in the two heating systems should not exceed the value for the maximum system w. NOTE This accessory requires accessory EP 1 SPLIT for installation in SPLIT indoor unit with integrated tank. NOTE This accessory requires accessory EP 2 SPLIT for installation in SPLIT indoor unit without integrated tank. Contents 1x 4x 2x 1x 2x 4x 1x 2x 1x 2x 2x 1x 1x 3 wire circulation pump Cable ties Heating pipe paste Insulation tape Flat gasket Round sleeve Circulation pump, EP21-GP20 Ball valve M Swivel nut 3-way valve Aluminium tape (pieces) Temperature sensor, EP21-BT2 w sensor), EP21- BT3 (return sensor) Control motor, EP21-QN25 Alpha switch 3

GB Pipe connection SPLIT indoor unit with integrated tank /SPLIT indoor unit without integrated tank Install as follows: First drain the boiler water reservoir/heating system if lled with water. The extra heating medium pump (EP21-GP20) is placed in a suitable location outside SPLIT indoor unit with integrated tank/split indoor unit without integrated tank. The shunt valve (EP21-QN25) is located on the supply line after SPLIT indoor unit with integrated tank/split indoor unit without integrated tank, before the t radiator in heating system 1. The return line from heating system 2 is connected to the shunt valve (EP21-QN25) and to the return line from heating system 1, see illustration page 5. The w sensor (EP21-BT2) is installed on the pipe after the heat medium pump (EP21-GP20). The return line sensor (EP21-BT3) is installed on the pipe from heating system 2. When installing the sensor, heat conducting paste must be used and the pipe must be insulated to obtain the correct temperature measurement. NOTE Incorrect installation can affect the function. Pump and pressure drop diagrams Available pressure, Tillgängligt tryck kpa kpa 70 60 50 40 30 20 CP2 CP1 PP2 10 Speed I Speed II Flow Speed III 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 l/h 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 Choose between seven settings on the pump. You can choose between three different constant speeds (I, II or III) or two different curves, one proportional pressure (PP) and one constant pressure (CP), where 1 is lowest and 2 highest. Shunt valve characteristics Flow Flöde (%) (%) 100 90 80 70 60 PP1 l/s 2-3 2-3 (vinkel) (angle) 50 40 30 20 10 1-2 1-2 (straight) (rak) 0 0 10 20 30 40 50 60 70 80 90 Vinkel ( ) Angle ( ) LEK KVS value 6,3 Recommended for floor heating areas up to 200 m². By-pass valve, (EP21-QN25) Connections, Ø 22 mm Return 3 1 2 Indoor module Flow pipe LEK 4

GB Outline diagram SPLIT indoor unit with integrated tank or SPLIT indoor unit without integrated tank with - extra shunt SPLIT indoor unit with integrated tank with EP21-QN25 EP21-GP20 EP21-BT2 EP21-BT3 AA25 W(T)PSK SPLIT CP1 CM1 Required Erf. säkerhetsutr. devices safety FQ1 FL1 BT 1 L8-16 SPLIT SPLIT SPLIT indoor med unit integrerad with integrated tank tank 5

GB SPLIT indoor unit without integrated tank with EP21-QN25 EP21-GP20 EP21-BT2 Överströmningsventil valve EP21-BT3 AA25 CP1 Required Erf. säkerhetsutr. safety devices FQ1 FL1 BT 1 SPLIT Hydrobox L8-16 SPLIT SPLIT indoor unit without integrated tank WWS 300 SPLIT / WWS 500 SPLIT Explanation AA25 Equipment box (RFV SPLIT) BT1 Temperature sensor, outdoor EP21-BT2 Temperature sensor, supply line 2 EP21-BT3 Temperature sensor, return 2 CM1 Expansion vessel CP1 EP21-GP20 EP21-QN25 FL1 FQ1 er vessel W(T)PSK Extra circulation pump Shunt valve Safety valve, hot water Mixer valve, hot water 6

GB Electrical connection NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. SPLIT indoor unit with integrated tank/split indoor unit without integrated tank must not be powered when installing. Electrical connection SPLIT indoor unit with integrated tank The electrical circuit diagram is at the end of these installation instructions. From - The return line sensor (EP21-BT3) is connected to terminal AA22:X4:5 and AA22:X4:6 on the same card. Connect valve actuator (EP21-QN25) as follows: - White cable (230 V signal) to spring terminal X6:8a - Brown cable (230 V signal) to spring terminal X6:7b - Blue cable (zero) to spring terminal X6:6b Connect circulation pump (EP21-GP20) as follows: - Blue cable (zero) to spring terminal X6:6a - Yellow/green cable (earth cable) to spring terminal X6:5a - Brown cable (phase) to spring terminal X6:4a EP21-QN25 White Brown Blue Blue Electrical connection, X6 8 7 6 Electrical connection, X6 EBV AA22 EP21-GP20 Yellow/green Brown 5 4 3 2 1 AA22:X4 1. Accessory L8-16 SPLIT is installed according to the supplied installation instructions. 2. The sensors are connected by twin cables (for example EKXX or LiYY) as follows for the load monitor card (EBV AA22) see image below: Use the enclosed round pin sleeves for splicing between the 2-cables and sensors BT2and BT3. -AA22 EBV Control Card >-EP21 Heating System 2 (Optional) Temp. sensor supply line 2 X4 Temp. sensor return 2 - The sensor used as w sensor (EP21-BT2) is connected to terminal AA22:X4:7 and AA22:X4:8 in the load monitor card's lower terminal block. 7

GB Electrical connection SPLIT indoor unit with integrated tank The electrical circuit diagram is at the end of these installation instructions. EBV AA22 AA22:X4 Connect valve actuator (EP21-QN25) as follows: - White cable (230 V signal) to spring terminal X6:8a - Brown cable (230 V signal) to spring terminal X6:7b - Blue cable (zero) to spring terminal X6:6b Connect circulation pump (EP21-GP20) as follows: - Blue cable (zero) to spring terminal X6:6a - Yellow/green cable (earth cable) to spring terminal X6:5a - Brown cable (phase) to spring terminal X6:4a X6 EP21-QN25 White Brown Blue Blue Electrical connection, X6 8 7 6 LEK Yellow/green Brown 5 4 1. Accessory EP 2 SPLIT is installed according to the supplied installation instructions. 2. The sensors are connected by twin cables (for example EKXX or LiYY) as follows for the load monitor card (EBV AA22) see image below: Use the enclosed round pin sleeves for splicing between the 2-cables and sensors BT2and BT3. EP21-GP20 3 2 1 -AA22 EBV Control Card >-EP21 Heating System 2 (Optional) Temp. sensor supply line 2 X4 Temp. sensor return 2 - - The sensor used as flow sensor (EP21-BT2) is connected to terminal AA22:X4:7 and AA22:X4:8 in the load monitor card's lower terminal block. The return line sensor (EP21-BT3) is connected to terminal AA22:X4:5 and AA22:X4:6 on the same card. 8

GB Temperature sensor installation K Install the temperature sensor with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape. NOTE Sensor and communication cables must not be placed near power cables. Program settings Select Service in menu 8.1.1 to gain access to menus 9.0 and the sub-menus. Then select Heating, "Heating + Cooling" or "Cooling" in menu 9.3.4, Heating system 2. Menu 3.0 and its submenus become accessible. In the sub-menus the curve t 2, t heat curve 2 and min- and max levels for the w line temperature 2 are set in the same way as heat system 1 under menu 2.0. See Installation and Maintenance Instructions for SPLIT indoor unit with integrated tank/indoor unit without integrated tank. 9

GB 10

MONTAGEANLEITUNG DE Allgemeines Dieses Zubehör kommt zum Einsatz, wenn SPLIT Inneneinheit mit integriertem Speicher/SPLIT Inneneinheit ohne integriertem Speicher in Gebäuden mit zwei verschiedenen Heizsystemen installiert wird, die unterschiedliche Vorlauftemperaturen erfordern, z.b. wenn ein Gebäude über Heizkörper und Fußbodenheizung verfügt. Im folgenden Text gilt Heizsystem 1 als das System, das die höhere Temperatur erfordert und das mit dem normalen Vor- bzw. Rücklaufanschluss verbunden wird. Als Heizsystem 2 gilt das System, das mit der niedrigeren Temperatur arbeitet. Der kombinierte Wasserdur s in beiden Heizsystemen darf den Wert für den maximalen Systemdur s nicht überschreiten. HINWEIS! Dieses Zubehör erfordert das Zubehör EP 1 SPLIT für die Installation in SPLIT Inneneinheit mit integriertem Speicher. HINWEIS! Dieses Zubehör erfordert das Zubehör EP 2 SPLIT für die Installation in SPLIT Inneneinheit ohne integriertem Speicher. Inhalt 1 St. 4 St. 2 St. 1 St. 2 St. 4 St. 1 St. 2 St. 1 St. 2 St. 2 St. 1 St. 1 St. 3-Leiter-Umwälzpumpe Kabelbinder Wärmeleitpaste Isolierband Flachdichtung Buchse Umwälzpumpe, EP21-GP20 Kugelventil M Überwurfmutter 3-Wegeventil Aluminiumklebeband (Abschnitte) Fühler, EP21-BT2 (V, EP21-BT3 Stellantrieb, EP21-QN25 Alpha-Kontakt 11

DE Rohranschluss SPLIT Inneneinheit mit integriertem Speicher/SPLIT Inneneinheit ohne integriertem Speicher Führen Sie die Montage wie folgt durch: Entleeren Sie zuerst das Wasser aus dem Heizwassergefäß/Heizkreis. Positionieren Sie die zusätzliche Heizungsumwälzpumpe (EP21-GP20) an einer geeigneten Stelle außerhalb von SPLIT Inneneinheit mit integriertem Speicher/SPLIT Inneneinheit ohne integriertem. Speicher. Bringen Sie das Mischventil (EP21-QN25) am Vorlauf nach SPLIT Inneneinheit mit integriertem Speicher/SPLIT Inneneinheit ohne integriertem Speicher und vor dem ersten Heizkörper für Heizsystem 1 an.verbinden Sie die Rücklaufleitung von Heizsystem 2 mit dem Mischventil (EP21-QN25) sowie der ng von Heizsystem 1, siehe Abbildung auf Seite13. Der V r (EP21-BT2) wird am Rohr nach der Heizungsumwälzpumpe (EP21-GP20) montiert. Der r (EP21-BT3) wird am Rohr von Heizkreis 2 montiert. Verwenden Sie bei der Fühlermontage Wärmeleitpaste und isolieren Sie das Rohr, um eine korrekte Temperaturmessung zu gewährleisten. HINWEIS! Bei einer falschen Montage kann die Funktionsweise beeinträchtigt werden. Pumpenkennliniendiagramm Verfügbarer Druck, Tillgängligt tryck kpa kpa 70 60 50 40 30 20 CP2 CP1 PP2 10 Speed I Speed II Fluss Speed III 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 l/h 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 Es stehen sieben Pumpeneinstellungen zur Auswahl. Sie können zwischen drei festen Drehzahlen (I, II oder III) bzw. zwei proportionalen (PP) oder konstanten Druckkurven (CP) wählen, wobei 1 der niedrigste und 2 der höchste Wert ist. Mischventilcharakteristik Durchfluss Flöde (%) (%) 100 90 80 70 60 50 PP1 l/s 2-3 (vinkel) (Winkel) 40 30 20 10 1-2 1-2 (gerade) (rak) 0 0 10 20 30 40 50 60 70 80 90 Vinkel ( ) Winkel ( ) KVS-Wert 6,3 Empfohlen für eine Fußbodenheizfläche bis 200 m². LEK Mischventil, (EP21-QN25) Anschlüsse, Ø 22 mm Rücklauf 3 1 2 Innenmodul Vorlauf LEK 12

DE Prinzipskizze SPLIT Inneneinheit mit integriertem Speicher oder SPLIT Inneneinheit ohne integriertem Speicher mit zusätzliches Mischventil SPLIT Inneneinheit mit integriertem Speicher mit EP21-QN25 EP21-GP20 EP21-BT2 EP21-BT3 AA25 W(T)PSK SPLIT CP1 CM1 Erforderliche Erf. säkerhetsutr. Sicherheitsausrüstung FQ1 FL1 BT 1 L8-16 SPLIT SPLIT Inneneinheit SPLIT med integrerad mit integriertem tank Speicher 13

DE SPLIT Inneneinheit ohne integriertem Speicher mit EP21-QN25 EP21-GP20 EP21-BT2 Überströmventil Överströmningsventil EP21-BT3 AA25 CP1 Erforderliche Erf. säkerhetsutr. Sicherheitsausrüstung FQ1 FL1 BT 1 SPLIT Hydrobox L8-16 SPLIT SPLIT Inneneinheit ohne integriertem Speicher WWS 300 SPLIT / WWS 500 SPLIT Erklärung AA25 Gerätegehäuse (RFV SPLIT) BT1 Außentemperaturfühler EP21-BT2 Fühler, Vorlauf 2 EP21-BT3 Fühler, Rücklauf 2 CM1 Ausdehnungsgefäß CP1 EP21-GP20 EP21-QN25 FL1 FQ1 erspeicher W(T)PSK Zusätzliche Umwälzpumpe Mischventil Sicherheitsventil, Brauchwasser Mischventil, Brauchwasser 14

DE Elektrischer Anschluss HINWEIS! Alle elektrischen Anschlüsse müssen von einem befugten Elektriker ausgeführt werden. Bei der Elektroinstallation und beim Verlegen der Leitungen sind die geltenden Vorschriften zu berücksichtigen. SPLIT Inneneinheit mit integriertem Speicher/SPLIT Inneneinheit ohne integriertem Speicher darf bei der Installation von nicht mit Spannung versorgt werden. Elektrischer Anschluss Inneneinheit mit integriertem Speicher Der Schaltplan sich am ieser Montageanleitung. Aus - - Der als V Fühler (EP21- BT2) wir mit Position AA22:X4:7 AA22:X4:8 an unteren Anschlussklemme Leistungswächterplatine (EP21-BT3) wir mit Position AA22:X4:5 AA22:X4:6 an ben Platine Ventilstellvorrichtung (EP21-QN25) wir wie folgt angeschlossen: - Weißer Leiter (230-V-Signal) an F X6:8a - Brauner Leiter (230-V-Signal) an F X6:7b - Blauer Leiter (Nullleiter) an F X6:6b. Umwälzpumpe (EP21-GP20) wir wie folgt angeschlossen: - Blauer Leiter (Nullleiter) an F -X6:6a - Gelber/grüner Leiter (Er leiter) an F -X6:5a - Brauner Leiter (Phase) an F -X6:4a Elektrischer Anschluss, X6 EBV AA22 AA22:X4 EP21-QN25 EP21-GP20 Weiß Braun Blau Blau Gelb/grün Braun Elektrischer X6 8 7 6 5 4 3 2 1 1. Das Zubehör L8-16 SPLIT wir gemäß r beil n Montageanleitung installiert. 2. Die Fühler wer wie folgt per Zweileiter (z.b. EKXX r LiYY) mit r Leistungswächterplatine n (EBV AA22) siehe unten. V Sie ie f um 2-Leiter sowie Fühler BT2 BT3 zu -AA22 EBV-Karte >-EP21 Heizsystem 2 (Zubehör) Temp.fühler, Vorlauf 2 X4 Temp.fühler, Rücklauf 2 15

DE Elektrischer Anschluss SPLIT innemodul utan integrerad tank Der Schaltplan befindet sich am Ende dieser Montageanleitung. EBV AA22 AA22:X4 Ventilstellvorrichtung (EP21-QN25) wird wie folgt angeschlossen: - Weißer Leiter (230-V-Signal) an Federklemme X6:8a - Brauner Leiter (230-V-Signal) an Federklemme X6:7b - Blauer Leiter (Nullleiter) an Federklemme X6:6b. Umwälzpumpe (EP21-GP20) wird wie folgt angeschlossen: - Blauer Leiter (Nullleiter) an Federklemme -X6:6a - Gelber/grüner Leiter (Erdleiter) an Federklemme -X6:5a - Brauner Leiter (Phase) an Federklemme -X6:4a X6 EP21-QN25 Weiß Elektrischer Anschluss, X6 8 Braun Blau Blau 7 6 LEK Gelb/grün 5 Braun 4 1. Das Zubehör EP 2 SPLIT wird gemäß der beiliegenden Montageanleitung installiert. 2. Die Fühler werden wie folgt per Zweileiter (z.b. EKXX oder LiYY) mit der Leistungswächterplatine verbunden (EBV AA22) siehe Abbildung unten. Verwenden Sie die folgenden Rundstifthülsen, um 2-Leiter sowie Fühler BT2 und BT3 zu verbinden. EP21-GP20 3 2 1 -AA22 EBV-Karte >-EP21 Heizsystem 2 (Zubehör) Temp.fühler, Vorlauf 2 X4 Temp.fühler, Rücklauf 2 - - Der als Vorlauffühler verwendete Fühler (EP21- BT2) wird mit Position AA22:X4:7 und AA22:X4:8 an der unteren Anschlussklemme der Leistungswächterplatine verbunden. Rücklauffühler (EP21-BT3) wird mit Position AA22:X4:5 und AA22:X4:6 an derselben Platine verbunden. 16

DE Fühlermontage K Der Fühler wird mit Kabelbinder, Wärmeleitpaste und Aluminiumband angebracht. Anschließend ist er mit dem beiliegenden Isolierband zu umwickeln. HINWEIS! Fühler- und Kommunikationskabel dürfen nicht in der Nähe von Starkstromleitungen verlegt werden. Programmeinstellungen Durch Auswahl von "Service" in Menü 8.1.1 erhalten Sie Zugri auf Menü 9.0 und die zugehörigen Untermenüs. Wählen Sie anschließend Heizung, "Heizung + Kühlung" oder "Kühlung" im Menü 9.3.4, "Heizkreis 2" aus. Dadurch erhalten Sie Zugri auf Menü 3.0 und die zugehörigen Untermenüs. In den Untermenüs werden Heizkurvenverlauf 2, Parallelverschiebung der Heizkurve 2 sowie Minimal- und Maximalwerte für Vorlauftemperatur 2 auf dieselbe Weise wie für Heizkreis 1 unter Menü 2.0 eingestellt. Siehe auch "Montage- und Wartungsanleitung" für SPLIT Inneneinheit mit integriertem Speicher/SPLIT Inneneinheit ohne integriertem. Speicher. 17

DE 18

Wiringdiagram/Elektrischer schaltplan 19

20

21

22

231884 ait-deutschland GmbH Industriestrasse 3 D D-95359 Kasendorf